HomeMy WebLinkAbout18-20205 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20205
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
-_PERMIT INFORMATION _ - = - LOCATION INFORMATION -
Permit#:20205 Issued: 9/07/2018 Address: 5901 13TH ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 214,485.60 Total Fees: 2,221.28 Subdivision: CITY OF ZEPHYRHILLS
Amount Paid: 2,221.28 Date Paid: 9/07/2018 Parcel Number: 11-26-21-0010-03800-0030
CONTRACTOR-INFORMATION OWNER INFORMATION
Name: BOBBY E. HILTON CONST INC Name: HILTON BOBBY E JR
Addr: 5415 16TH ST Address: 39942 OTIS ALLEN RD
ZEPHYRHILLS, FL. 33540 ZEPHYRHILLS FL 33540-7715
Phone: (813)997-0515 Lic: Phone: 813-997-0515
Work Desc: CONSTRUCT SINGLE FAMILY 1,904 SQ FT
APPLICATION FEES
BUILDING FEE 1,212.29 ELECTRICAL FEE 250.88 PLUMBING FEE 167.25
MECHANICAL FEE 117.08 WATER METER RES 3/4" 473.78
Inspections Adquired
F OTER 2ND ROUGH PLUMB -Mlbu INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONT CT RS SI NATURE PERMIT OFFI
PERMIT EXPIRES IN G MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
r
Date Received 0 M48 Phone Contact for Permitting
Owner's Name Owner Phone Number 6>`3- -O S 1�
Owner's Address 3 a C;Ti S A ,) �' Owner Phone Number
Fee Simple Titleholder Name s Owner Phone Number
Fee Simple7itleholder Address
C�J l�J L
JOB ADDRESS h � OT#
SUBDIVISION PARCEL ID# 34`0 "C010 L13?Oa�
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR H
ADD/ALT = SIGN = DEMOLISH
Fwl INSTALL REPAIR
PROPOSED USE = SFR Q COMM = OTHER
TYPE OF CONSTRUCTION BLOCK FRAME = STEEL =
DESCRIPTION OF WORK 6UJI 0 NY;1J q,10cT
BUILDING SIZE SQ FOOTAGE HEIGHT U
[ZfB,UILDING $ oe
/30l OoCd, VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE EEf PROGRESS ENERGY W.R.E.C.
=PLUMBING $ ga �� r
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION � ��(�►�'�-'�y
� )')IU��
sp
t6
=GAS = ROOFING = SPECIALTY = OTHER p
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO wZ. �``�
G
BUILDER COMPANY � H OJV CcA,s�R�-f i� Luc
SIGNATURE REGISTERED Y N FEE CURREN N
Address o-Tts PW-1-N RC). License#
ELECTRICIAN ` COMPANY + �� Lla, J �C
SIGNATURE REGISTERED Y/ N FEE CURREN
Address JF`% License# 0 Io [i
PLUMBER' COMPANY
SIGNATURE �� REGISTERED Y/ N J FEE CURREN Y/N
Address c5 ® � I License# �C Z S- -(i b-2—
MECHANICAL COMPANY
SIGNATURE / ,,/REGISTERED Y/ N FEE CURREK Y/N
Address p ./J `mod/* License#
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application-for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County..
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior.to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the 'owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work*
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I-understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,WaterMastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress. Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by_a professional engineer
licensed by the State of Florida-.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the"stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
-the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required. .
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations,of:any codes. Every permit issued shall become invalid
unless the work authorized by's'uch permit is commenced within`six months of permit issuance, or if work-authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S. 117.03)
Al OWNER OR AGENT CONTRACTOR ' — —
Subscribed and swom to(or affirmed)before me this Subscribed and om to(or a ed) of re me is
by by
Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
Notary Public e Notary Public
Commission No. Commission No.
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
' Bobby Hilton Construction-5901 13th St-Single Family 1,904 sq ft
Column
SQ.' FEET PRICE
MAIN OR LIVING: 1,904 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 214,485.60
FEE SHEET $ 1,115.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,212.30
ELECTRICAL: $ 250.88
PLUMBING: $ 167.25
MECHANICAL: $ 117.08
SUB-TOTAL $ 1,747.50
TOTAL $ 1,747.50
SEWER: credits home demo
WATER: credits home demo
IRRIGATION: $ -
TOTAL: $ -
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE
FIRE
5% $ -
TOTAL: $ - credits home demo
SUB-TOTAL $ 2,221.28
PARK IMPACT FEES credits home demo
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ - credits home demo
T I F'S: credits home demo
99% $ -
1% $ -
TOTAL: $ 2,221.28
Bobby Hilton Construction-5901 13th St-1,904-sgft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 1,904 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 214,485.60
FEE SHEET $ 1,115.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,217.30
ELECTRICAL: $ 250.88
4; PLUMBING: $ 167.25
MECHANICAL: $ 117.08
SUB-TOTAL $ 1,752.50
Public Fee 1% $ ' 17.53
TOTAL $ I J70.03
SEWER: Fee waved
WATER: Fee waved
IRRIGATION: $ -
TOTAL: $ -
WATER METER:1 $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE Fee waved
FIRE Fee waved
5% $ -
TOTAL:1 $ -
SUB-TOTAL $ 2,243.81
PARK IMPACT FEES Fee waved
SIF'S: Fee waved
100.0% $ -
1.0% $ -
TOTAL: $ -
T I F'S: Fee waved
99% $ -
1% $ -
TOTAL: $ 2,243.81
Single Family Dwelling
Plan Review:CO mments:
1:" F.F.E. shall be a minimum of.8 above.the road elevation and"an engineered site plan. . .
2_ Lots shall be graded.to comply with.R401.3 of the F.B.C.
3.- .Compaction lest required if 24" or more of fill dirt is brought in:at any one place. :
4:. 'Tie in survey-required before pouring concrete..
5. _Driveways require a R.O.W.use permit: All 4.sides of driveway.thru the sidewalk shall-have. "
expansion material:. . .
6.." All setbacks.'shall be'met:
7. :Ali.property markers�shall be_uncovered and'marked at time of first:inspection:
8." :All A.D.A.requirements shall be met.
9. No:electric;plumbing,mechanical;"or framing shall be covered without an:inspection and
approval"first.
10. All Garages shall comply,with section R302:6 of the F.B:C: (F.i.re Sp.aration.
�
11.:Appliaiices.shall iiot.be installed in a location where subject to."mechanical"damage:unless.
protected by approved barriers. M303.4 of."the F.B.C. "
12. Water heaters shall comply:with section:P607.3 of the"F.B.C:
13. Foundation supports for-A/C units shall be raised at least 3"above finish ed"grade. M1308.1
14. Return air in All-.bedrooms..F.B.C. NI1620.4,,
15. Smoke detectors are to be'installed:"in accordance.with R313:1-oftheT.B.C.
.16::All glazing requirements are:.to be'in accordance with R308.4.of the RB:C.
17. All means,of egress"are to be in accordance with R311:.of the F.B.C.,
18. `.`Green gypsurn.board shall not be used:as"a"backer in:showers or tubs."R702.4.2.F.B.C.
19. Combination-type"AFCI breakers are required:at all.locations-requiring an AFCI.type breaker.
20: Carbon'monoxide alarms will be required in.-new.construction thzat uses fossil-burning heating
or appliances or an attached garage_: They shall be installed in accordance with"the F.B.C::
21. All plumbing,mechanical,:and electrical shall:be separate from unit to:unit. This includes all,
underground plumbing and electric.
22.--A11,2016:N.E C.. Codes.will.be enforced.
..
23:-Tamper- Resistant Receptacles in accordance with 406.11 of the 20"16 N".E:C
.24.:In, accordance:.with the Land.Development:Code,lots shall be sodded before final at least 10. ."
feet around:the structure. : .
25. Blower"door test and blown in insulation card shall be"provided before C..O . :"
26 A copy®fthe enemy cacls.shall be with permit"at all times.
2T. Copy of final insulation report shall be:provided with.permit-before fnab .
F.F.E.-Finished Floor Elevation
RB.C=Florida Building Code Oh Edition
R.O.W.-Right of Way
A.D:A:-Americans with Disabilities Act" N.E.C.-National Electric Code(2011)
Legend
P.O.C. Point of Commencement ® Indicates Asphalt Pavement
P.C.P. Permanent Control Point
P.R.M. Permanent Reference Monument T.O.B. Top of Bank
P.O.B. Point of Beginning T.O.S. Toe of Slope
P.O.L. Point on Line Conc. Concrete
F.I.R. Found Iron Rod Asph. Asphalt
F.I.P. Found Iron Pipe Mas. Masonry
F.N.& D. Found Nail & Disc Fr. Frame W P.S.M. �+
F.C.M. Found Concrete Monument W.F. Wire Fence 6061 1
R Per Legal Description or Flat{Recorded) Wd.F_ Wood Fence
C Calculated CLF Chain Link Fence
(M Field Measured S.P. Screen Porch
B/D Proportioned Section Breakdown CP Carport
RAD. Radius OHL Overhead Utility Line
Ch.L, Chord Length U.F. Utility Pole
Ch.B. Chord Bearing 11 Edge of Pavement S
S.I.R. Set 1/2" Iron Rod Capped with U/C Utility Cylender
Identification "PSM 6061" R/W Right of Way
S.N.& D. Set Nail & Disc q Centerline / \ SCALE: 1" = 30'
Stamped "PSM 6061" �-
A/C Air Conditionerr,0 7
VD
o°4ioce%,k \� 0 // 30' 60'
os
/ `o / ,. ;
OZ iyit 0 f Lot
11 o
/,ap lR� F>R NE Gocner cvP
got
LA
ao t4 C09 �! j f
o f yR•03 N,of °� 66 �. / cS '�N.... .
-
c� PAR 1
A / '' ✓ Jam.3 3 ,
VACANT ,3g '1AND vo
O /
ar. '0 2 / / PARCER / �aF :e�� ,��
`\ p COP
NL / 0k R h 10 I �r'sr ern.
o- N -- of Epp s "` y56 e/ N
\� ,� 139• ti "�g5 col \ '�r:
- °k
All
66 �-
\\ -y U.`r
a oaf• attt+ 0 Nv"
�$ cc b"q ec
° ° /
�✓ °i4 cc
`3g-�—
ot
S
10
Vol
2+11''
31009 Pasco Road Phone: (352) 588-3680
John Walsh, Professional Surveyo Ha ! San Antonio, Florida 33576 Email: psm606l@gmall.com
Professional License number LS 6061 BOUNDARY SURVEY
Not valid without the signature and the original raised seal Client: , Bobby E Hilton Jr.
of a Florida licensed surveyor and mapper. work order number: W18•-0501
Date of Survey: 5/5/2018
Additions or deletions to this survey map or report by other than the Certified To: Bobby E. Hilton Jr.
signing party prohibited without written consent of the signing party.
S � V n�plCl�p I$Nff COW�V R9 5510%AM INN, John Walsh, P.S.M.
PA GE SECTION 11 5F-� P'A0� 2 r-OP 516NA-ru P,,F- & 5F,�P4-
2 OF 2 TOWNSHIP 26 S RANGE 21 E
PASCO COUNTY, FLORIDAI Florida Surveyor's Registration No. 6061
LEGAL DESCRIPTION:
Parent parcel; (O.R.B. 9708, Page 2837)
Lots 3, 4, 5, and the North 1/2 of Lot 6, Block 38, CITY OF ZEPHYRHILLS (Town of ZEPHYRHILLS per plat), a
subdivision according to the plat thereof recorded in Plat Book 1, Page 54, of the Public Records of Pasco
County, Florida.
Parcel I
Lot 3 and that portion of Lot 4, Block 38, Town of ZEPHYRHILLS, as recorded in Plat Book 1, Page 54, of the
Public Records of Pasco County, Florida, described as follows:
Commence at the Southeast Corner of Block 38 as monumented (1/2" diameter Iron Rod) and run thence N.
23*21'39" W., along the Easterly line of said Block 38, a distance of 187.48 feet, to a 1/2" Iron rod with ID
Cap "PSM 6061" for a POINT OF BEGINNING; thence S. 66'36'21" W., , a distance of 139.88 feet, to a 1/2" Iron
rod with ID Cap "PSM 6061" and the Westerly line of Lot 4;
thence N. 23*23'41" W., along said Westerly, line of Lot 4 and the Westerly line of said Lot 3, a distance of
52.60 feet, to a 1/2" Iron Ron without ID Cap and the Northwest corner of said Lot 3; thence N. 66'35'35" E.,
along the Northerly line of said Lot 3, a distance of 139.90 feet, to a 1/2" Iron Rod without ID Cap and the
Northeast Corner of said Lot 3; thence S. 23*21'39" E., along the Easterly line of said Block 38, a distance of
52.63 feet to the POINT OF BEGINNING.
Containing 7,347 square Feet or 0.17 acre more or less
Parcel 2
That portion of Lot 4, Lot 5, and the North 1/2 of Lot 6, Block 38, Town of ZEPHYRHILLS!, as recorded in Plat
Book 1, Page 54, of the Public Records of Pasco County, Florida, described as follows:
Commence at the Southeast Corner of Block 38 as monumented (1/2" diameter Iron Rod) and run thence N.
23'21'39" W., along the Easterly line of said Block 38, a distance of 134.95 feet, to a 5/8" Iron rod with ID
Cap "LB 8859" for a POINT OF BEGINNING; thence S. 66*37'06" If. along the South line of the North 1/2 of said
Lot 6, a distance of 139.84 feet, to a 6/8" Iron rod with ID Cap "LB 8859" and the Westerly line of said Lot 6;
thence N. 23*23''41" W., along the Westerly lines of said Lots 6, 5 and 4, a distance of 62.50 feet, to a 1/2"
Iron Rod with ID Cap "PSM 6061"; thence N. 66*36'21" E., a distance of 139.88-feet, to a 1/2" Iron Rod with ID
Cap "PSM 6061" and the Easterly line of said Block 38; thence S. 23*21'39" E., along said Easterly line of said
Block 38, also the Easterly lines of Lots 4, 5, & 6, a distance of 62.53 feet to the POINT OF BEGINNING.
Containing 7,343 square Feet or 0.17 acre more or less.
NOTES:
The purpose of this BOUNDARY Survey is to subdivide the vacant platted property into
two Parcels.
This survey was prepared without the benefit of a title opinion or abstract of title, no
search of the public records regarding the subject parcel was done by this office.
Therefore there may be instruments found in the public records affecting the
boundaries of the subject property that have not been shown.
No underground utilities or other apparatus were located for this survey, except as
shown. No open and notorious evidence of easements were observed on the subject
parcel, other than those shown.
Bearings shown hereon are based on the North line of Lot 3, Block 38, as monumented
and shown hereon being N. 66"35'35" E. assumed meridian.
Legal description based on that Warranty Deed recorded in Official Records Book (O.R.B.)
9708, page 2837, of the Public Records of Pasco County, Florida.
This survey does not indicate approval by any governmental agency.
John h1sh, Professi on al Surve er 31009 Pasco Road Phone: (352) 588-3680
or a San Antonia, Florida 33676 Email: psm606i@gmail.com
R i
BOUNDARY�Y �Ej�
Client: V'�U Hilton,
Professional License number LS 6061 BOUNDARY SURVEY
Not valid without the signature and the original raised seal Cli�en�t: Bobby E. Hilton, Jr.
of a Florida licensed surveyor and mapper. Work order number: W18-0501
Date of Survey� -5,/5/_%8 -- -..
bt V'
Additions or deletions to Chip survey map or report by other than the Certified To: o
signing party prohibited without written consent of the signing party.
H WHO V 15 NNOM MEN XMINMI 0h Wa
PA GE SECTION If -
TOWNSHIP 26 8 RANGE 21 E
2 OF 2 PASCO COUNTY, FLORI A Fto a 15urvwor�s Re#istras6n/,1o. 6061
2018139915
Permit NO. ParcallDNo (1-a6-al-oolo-®,xiSS�� eo3c�
NOTICE OF COMMENCEMENT
stole., f_W;r}A, County of
-t13�•+",�.',,4;rr��.��?�.,s�yy,�*{c�i5n >�r ,Xov�t,��'?eQrWOs•fgcu.roafproperty.aramarcatdaneewYMspeaOar7fa.Florida statuus..
the•follcitMrrg'tntornreSanTs provided in Sus tidttee oT Camnenre�nc
i. DesatpttanatProAeny;.Parcei.tdardittca6onNo.. 11-ab�al-Cols+-�3Ss�-�'a3e
Street Address I�1h Zwth3�1�;11,3/ l�l
z. General Description of improvement QLj l d AIp W
S Owneriffittmaytiycr�rorLesste1eWonnaftwillttheEesseeconlracted for tbeknorovemealt
3�t�ya pis A1h-�t Rd� z`-f�HUIS �L
Address City State
Interest In Property: Ot�r r<xfZ.
Nome of Fea Simple TlBe Wder.
({tBe�mtAivai Owitef/lsferf above)
a. c� gabbq z }i 1 e, C' d//.5� '�iVC• Off` State. .
Z4gUa csli t �jjtPv �d Zri�iuT
Address City'- v State
contractoes Telephone No.: /3-�1 ]-01519
s. surely..
Name
AcYaatSst Cttx state
Atnotadd&Yel:S Telaphone.Noa
S. Lender
Name
Address City State
letfdefs Telephone Noc
7: adttata•Rra.Sffite o!iAattla'designHted by^tire ovaw alpon whom?ixi0i es br'Aiher.doctgnecitg'*may:;bE=e ed gas;provided by
Galan•Tile:t;(:.?+lc�'i,=t'n'.d'ata6�tss: `t E- W' f�,�
C/3 W (��, L�
Name z O LL I kJ _j
U U3
Address Cpy State 11 (D O Z i lV
Telephone Number of Designated Person: C) W a t- n
Q W W Z f/J (l.
8 thatl_dlOwtot ii"' t'thbove-deetynates. ( of � - O �� q ��•
wtec eivea•eopy of ft Uenes P bfw as provided b Sec4w7=U33�1M FtoddaStatutas. f W O Of C_y O
Telephone Number off son or ErAWD ed bY0— iZ-} fJ t�
9. Expiration date of Notice of Commencement(that expiration date may not be before the completion of construction and final payment to the C)Q 0 LIJ tZ O
contractor,but vvlA be one year from the date of recording unless a different date is specified): = V CO W
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT Q�� � Q'
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,•PART 1 SECTION 713.13 FLORIDA STATUTES. AND CAN ���� � Ll
RESULT-IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE'OF COMMENCEMENT MUST BE tZ/ :D 2 O J
RECORDED aMD POST£Ct•t?at• aE,fOBagfTE 6EFORE THE FfRST INSPECTfON._IFYOU iNl END TO OBTAIN FINANCING,CON5UL7 x >
iNlfUiYOUR•:tP1dt36ROR'ANib77ORNEY8FF013ECOMMENCtNGTAMC1OR�RECORDiNG?rt3LiRA+t03iGEC3FCOAiIctPNCEfaFNT �� O Q O W
v4mefIre Med=be9efdedargttratk?iaavammftt Cocagotng•nat3�oPeommenrt�ivt�st�ndfirec$isfar}ashne¢ r!areh4rebt+rhabest LL O CGFli
of- 2o C/)
STATE OF FLORIDA LtJ U) <L
COUNTY OF PASCO W 7 �J
Signature of er cr Lessee, Owner's or Leasable Authorized 5 LL
1 Rept:1983305 Rae: 10.00 Offieer/OkedodPartw/Atanager x O
DS: 0.00 IT: 0.00
08/17/2018 J. R., Dpty Clerk9TUIiyOitk:e_
The faregoir*irotrumentwas ad=vAedpdb sib re.me.Ihla T k day aP by 26�
ac (type of authority:eg.officer:txestee attorney fact)for °� • (' i s
(name of pally on behalf of vbrorn instrument was etecrned). • [L
Personally Known 03'2a Produced Identification❑ Notary Sig
ititt6lrrffrr, e "'
Type of ldeiufifleallon Produced � JLy:r• /�. Noma(PrtM 'i k, rj
NRY
PAULR S.0,NESL,P".6 PASCO CLERK &COt7PTROLLgR� �®
08/17/201 �j }2
�`G OR 8K I i PG
wadatstarBtnonoacanmencomant�cnssote•,,4TEi0E v����
..........
w
-771
x _
013-780-0020 City of Zephyrhills Permit Application Fax-E13-780-0021
Building Department a
Date Received phone Contact for Permitting 1 S is
Owner's Name Owner Phone,Number �r" - -0 �s
Owner's Address 3 iS Alln IZO?- Owner Phone Number —�
Fee Simple.Titleholder Name Owner Phone Number �—
r
i -
Fee Simple Titleholder Address r f !
JOB'ADDRESS l J 13 h Z� j j LOT#•
SUBDIVISION PARCEL ID# 'I��a�` a I CAl 0- G' ,�O o-0G3�
i (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR, ADDIALT Q -SIGN Q Q DEMOLISH
j INSTALL 8 REPAIR
PROPOSED USE C] SFR ] COMM OTHER
TYPEIOF CONSTRUCTION Q?? BLOCK, --,FRAME STEEL 0
DESCRIPTION OF WORK
f i ..
t �
t BUtLBING SIZE �� SCt FOOTAGE I 01 HEIGHT
! ; 14
l BUILDING $ '` n�'.
�on`91..7�-:�� VALUATION OF TOTAL CONSTRUCTION '
/%`
l�ELECTRtCAL ($ — AMP SERVICE [T� PROGRESS ENERGY Q W.R.E.C. ✓
F_ i
QPLUMBING $
OMECHANlGAt $ VALUATION OF MECHANICAL INSTALLATION
r�
OGAS Q ROOFING Q SPECIALTY LJ OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER %� -� COMPANYb�(: H`�o�u GcA,5TRrn'( au
SIGNATURE G, 4 V REGISTERED N FEE CURREN I Ul N.
Address License#
I r
ELECTRICIAN irr COMPANY:SIGNATURE V r r tZo REGISTERED Y/'N FEE CURREn _Y/N -
-.
Address �' License# ( 1;; )l o
PLUMBER Jj/!� / COMPANY ` t�StAJJ�rSs Gs.�Gll,rt 1�4-
SIGNATURE r / rVtJ REGtSTEREp I -;�/'N FEE CURREt Y/N
Address I,Gf 6 1 License# Fc, q -2-
MECHANICAL I COMPANY �lQ{�9.`5 _&,,9s,-�o—'N�-�-� �sy s-LAl
SIGNATURE —�'�"" ,( REGISTERED Y/ N FEE CURREr+. t Y/�N �j�
Address Q /� License# 4 4 G o Y 39 i.
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREi Y/N
Address,. License#
RESIDENTIAL Attach(2)-Plot Plans;(2)aets.of Building Plans;(1)set of Energy Forms;R-O W Peimit for new donstruction,
Minimum#en(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w!Silt Fence installed,
Sanitary Fatalities B 1 dumpster;Site Work Permit for subdivisionstlarge projects
COMMERCIAL Attach(2)complete sets of,Building Plans,plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after subrriittal date:Required onsite,Construction Plans,Storrnwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach-(2).sets of Engineered.Plans.
—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2600,a Notice of Commencement Is required, (A/C upgrades over$7500)
" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (oopy.of contract required)
Reroofs if shingles Sewers Service Upgrades A/C ' Fence's(Pidt/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
Manual S Compliance Report Job: R0818410
-P� wrightsoft° p p Date: 0 8/1 012 01 8
Entire House By. MKc
Bobby Hilton Construction,Inc. Plan: 611600
39942 Otis Allen Rd,Zephyrtills,FL33540 Phone:(813)997-0515
Project • •
For. Bobby Hilton Construction,Inc.
Zephyrhills,FL 33540
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 17415 Btuh Entering coil DB: 77.3'F
Outdoor design WB: 772°F Latentgain: 3659 Btuh Entering coil WB: 63.8°F
Indoor design DB: 75.0'F Total gain: 21074 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SplitASHP
Manufacturer., Franklin or Eqv. Model: GSZ160241+ASPT29B14
Actual airflow: 800 cfm
Sensible capacity: 18000 Btuh 103%of load
Latent capacity: 6000 Btuh 164%of load
Total capacity: 24000 Btuh 114%ofload SHR: 75%
Heating Equipment
Design Conditions
Outdoor design DB: 42.9°F Heat loss: 15763 Btuh Entering coil DB: 69.1OF
Indoor design DB: 70.0'F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SplitASHP
Manufacturer. Franklin or Eqv. Model: GSZ160241+ASPr29B14
Actual airflow: 800 cfm
Output capacity. 24000 Btuh 152%ofload Capacity balance: 33 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elecstrip
Manufacturer. Model:
Actual airflow: 800 cfm
Output capacity. 5.0 kW 108%of load Temp.rise: 31 OF
Meets all requirements ofACCA Manual S.
*wrightsoft® 2018-Aug-1411:45:58
.,, •d, �.���, RigitSute®Uriversal201818.0.19RSU20773 Pagel
818410-Bobby Mon CorstructiodR0818410np CaIc=MJ8 FrortDoorfaces:E
-� Job: R 0
wrightsoft° Project Summary Date: 08/1012018 Entire House By. MKc
Bobby Hilton Construction,Inc. Plan: 611600
39942 Otis Allen Rd,Zepftffhlls,FL33540 Phone:(813)997-0515
Project • •
For. Bobby Hilton Construction,Inc.
Zephyrhills,FL 33540
Notes: Load calculation was obtained from a digital copy of the CAD drawing.
Design Information
Weather. Tampa Intl AP,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 12742 Btuh Structure 13002 Btuh
Duds 3022 Btuh Ducts 4413 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 dm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 15763 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17415 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2352 Btuh
Ducts Btu
Central vent(0 dm) 1300 Btuh
Heatingg Coolingg (none)
Area(ft') 1382 1382 Equipment latent load 3659 Btuh
Volume(fl3) 11056 11056
Air changes/hour 0.45 023 Equipment Total Load(Sen+Lat) 21074 Btuh
EquIv AVF(cfm) 83 42 Req.total capacity at 0.75 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Franklin or Eqv. Make Franklin or Eqv.
Trade Split HP Trade Split HP
Model GSZ160241 Cond GSZ160241
AHRI ref 201667298 Coil ASPT29B14
AHRI ref 201667298
Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER
Heating Input Sensible cooling 18000 Btuh
Heating output 24000 Btuh @47-F Latentcooling 6000 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual airflow 800 dm Actual airflow 800 cfrrl
Airflowfactor 0.051 dmA3tuh Airflowfador 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.83
Capacity balance point=33 OF
Backup:Aux Heat
Input=5 kW, Output=17061 Btuh,100AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrigF�tsoft- 2018-A�-1411 A5:58
t •W •• Right-Sute@Uriversal2018l8.0.19RSU20773 Pagel
...818410-Bobby H lton CorstnictiorAR0818410np Calc=NUB Front Doorfaws:E
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: R0618410 Builder Name: Bobby Hilton Constru tion,In
Street: -�'q'01 1 3 Permit Office: Viiate Parir
City,State,Zip: Zephyrhills,FL,33540 Permit Number: W S-
Owner. Bobby Hilton Construction,Inc. Jurisdiction: fl &116"
Design Location: FL,Tampa County: Pasco(Florida Climate Zane 2)
1. New construction or existing New(From Plans) 9. Wall Types(1414.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 1117.30 ft2
b.Frame-Wood,Adjacent R=13.0 296.67 ft2
3. Number of units,if multiple family 1 c,N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1381.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1381.00 ft2
6. Conditioned floor area above grade(ft2) 1382 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(104.1 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 225
a. U-Factor. Dbl,U=0.33 104.10 ft2
SHGC: SHGC=0.28
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 24.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Strip Heat 24.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.309 ft.
Area Weighted Average SHGC: 0.280 14.Hot water systems
8. Floor Types (1382.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1382.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits CF,Pstat
Glass/Floor Area: 0.075 Total Proposed Modified Loads: 41.96 PASS
Total Baseline Loads: 43.85
I hereby certify that the plans and specifications covered by Review of the plans and OTC Srgp�
this calculation are in compliance�with the Florida Energy specifications covered by this V
Code. calculation indicates compliance
++ i.
with the Florida Energy Code.
PREPARED BY: Before construction is completed W.
08-14-18
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes. 1
with the Florida Energy Code. COD wn't4�
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(111402.4.1.2).
8/14/2018 11:49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
h
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: R0818410 Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1382 Lot#
Owner Name: Bobby Hilton Construction,In Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Bobby Hilton Construction,In Rotate Angle: 0 Street:
Permit Office: Winter Park Cross Ventilation: No County: Pasco
Jurisdiction: 582400 Whole House Fan: No City,State,Zip: Zephyrhills,
Family Type: Single-family FL, 33540
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1382 11056
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Bed2 165 1320 No 1 1 1 Yes Yes Yes
2 Wic 37 296 No 0 1 Yes Yes Yes
3 MBed 200 1600 No 2 1 1 Yes Yes Yes
4 Closet 31 248 No 0 1 Yes Yes Yes
5 Bed3 148 1184 No 1 1 1 Yes Yes Yes
6 Kitchen 211 1688 Yes 0 1 Yes Yes Yes
7 Living 288 2304 No 0 1 Yes Yes Yes
8 Bath 57 456 No 0 1 Yes Yes Yes
9 Pantry 22 176 No 0 1 Yes Yes Yes
10 MWic 65 520 No 0 1 Yes Yes Yes
11 MBath 87 696 No 0 1 Yes Yes Yes
12 Hall 71 568 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Bed2 25.7 ft 0 165 ft2 0 0 1
2 Slab-On-Grade Edge Insulatio Wic 9.3 ft 0 37 ft2 ___ 0 0 1
3 Slab-On-Grade Edge Insulatio MBed 28.3 ft 0 200 ft2 — 0 0 1
4 Slab-On-Grade Edge Insulatio Closet 2.3 ft 0 31 ft2 — 0 0 1
5 Slab-On-Grade Edge Insulatio Bed3 11.7 It 0 148 ft2 0 0 1
8/14/2018 11.49 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
6 Slab-On-Grade Edge Insulatio Kitchen 12.7 ft 0 211 ft2 0 0 1
7 Slab-On-Grade Edge Insulatio Living 34 ft 0 288 ft2 — 0 0 1
8 Slab-On-Grade Edge Insulatio Bath 1 ft 0 57 ft2 — 0 0 1
9 Slab-On-Grade Edge Insulatio Pantry 1 ft 0 22 ft2 ____ 0 0 1
10Slab-On-Grade Edge Insulatio MWic 6.7 ft 0 65 ft2 — 0 0 1
11Slab-On-Grade Edge Insulatio MBath 9 ft 0 87 ft2 — 0 0 1
12SIab-On-Grade Edge Insulatio Hall 1 ft 0 71 ft2 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 1496 ft2 288 ft2 Light 0.65 No 0.9 No 0 22.6
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1381 ft2 y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Bed2 38 Blown 165 ft2 0.1 Wood
2 Under Attic(Vented) Wic 38 Blown 37 ft2 0.1 Wood
3 Under Attic(Vented) MBed 38 Blown 200 ft2 0.1 Wood
4 Under Attic(Vented) Closet 38 Blown 30 ft2 0.1 Wood
5 Under Attic(Vented) Bed3 38 Blown, 148 ft2 0.1 Wood
6 Under Attic(Vented) Kitchen 38 Blown 211 ft2 0.1 Wood
7 Under Attic(Vented) Living 38 Blown 288 ft2 0.1 Wood
8 Under Attic(Vented) Bath 38 Blown 57 ft2 0.1 Wood
9 Under Attic(Vented) Pantry 38 Blown 22 ft2 0.1 Wood
10 Under Attic(Vented) MWic 38 Blown 65 ft2 0.1 Wood
11 Under Attic(Vented) MBath 38 Blown 87 ft2 0.1 Wood
12 Under Attic(Vented) Hall 38 Blown 71 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
luRAW— Fraction Ah-qnr rra(Jp%
1 N Exterior Frame-Wood Bed2 13 13 0 8 0 104.0 ft2 0 0.25 0.1 0
2 W Exterior Frame-Wood Bed2 13 12 8 8 0 101.3 ft2 0 0.25 0.1 0
3 S Exterior Frame-Wood Wic 13 . 5 4 8 0 42.7 ft2 0 0.25 0.1 0
4 W Exterior Frame-Wood Wic 13 4 0 8 0 32.0 ft2 0 0.25 0.1 0
8/14/2018 11:49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
Space R-Value Ft In Ft In Area R-\/aluo Fraction Ahsor Gra
F_5 S Exterior Frame-Wood MBed 13 13 8 8 0 109.3 ft2 0 0.25 0.1 0
6 W Exterior Frame-Wood MBed 13 14 8 8 0 117.3 ft2 0 0.25 0.1 0
7 N Exterior Frame-Wood Closet 13 2 4 8 0 18.7 ft2 0 0.25 0.1 0
8 N Exterior Frame-Wood Bed3 13 11 8 8 0 93.3 ft2 0 0.25 0.1 0
9 N Exterior Frame-Wood Kitchen 13 12 8 8 0 101.3 ft2 0 0.25 0.1 0
_10 S Garage Frame-Wood Kitchen 13 5 0 8 0 40.0 ft2 0 0.25 0.1 0
11 N Exterior Frame-Wood Living 13 17 4 8 0 138.7 ft2 0 0.25 0.1 0
12 E Exterior Frame-Wood Living 13 16 8 8 0 133.3 ft2 0 0.25 0.1 0
13 S Garage Frame-Wood Living 13 17 4 8 0 138.7 ft2 0 0.25 0.1 0
14 E Garage Frame-Wood Pantry 13 5 0 8 0 40.0 ft2 0 0.25 0.1 0
15 S Exterior Frame-Wood MWic 13 6 8 8 0 53.3 ft2 0 0.25 0.1 0
_16 E Garage Frame-Wood MWic 13 9 9 8 0 78.0 ft2 0 0.25 0.1 0
17 S Exterior Frame-Wood MBath 13 9 0 8 0 72.0 ft2 0 0.25 0.1 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E Insulated Living None .35 3 6 8 20 ft2
2 S Insulated Kitchen None .46 2 7 6 7 17 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 W 2 TIM Low-E Double Yes 0.33 0.28 N 15.0 ft2 1 ft 0 in 6 ft 0 in Drapes/blinds Exterior 5
2 W 6 TIM Low-E Double Yes 0.33 0.28 N 20.1 ft2 5 ft 0 in 1 ft 2 in None None
3 W 6 TIM Low-E Double Yes 0.33 0.28 N 15.0 ft2 5 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
4 N 8 TIM Low-E Double Yes 0.33 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
5 N 9 TIM Low-E Double Yes 0.33 0.28 N 9.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
6 E 12 TIM Low-E Double Yes 0.33 0.28 N 30.0 ft2 4 ft 4 in 0 ft 8 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 420 ft2 420 ft2 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1289.9 70.81 133.17 .2649 7
8/141201811:49 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heatt None COPA 24 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:16 24 kBtu/hr 800 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 225 ft2 Attic 150 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling Jan Feb M Apr
r Ma Sep Oct
ar May Jun Ju Aug Nov Dec
H an Fb Mar Jun u! Au S Oct Nov Dec
Vent ng Jan H Feb L�l Mar Apr € May Jun il Jul Aug ns W Oct N Nov H Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
8/14/2018 11:49 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 6
ti
V
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 Bed2
Default(8 Ibs/sq.ft. ftz ft 0.3 Wic
Default(8 Ibs/sq.ft. ftz ft 0.3 MBed
Default(8 Ibs/sq.ft. ftz ft 0.3 Closet
Default(8 Ibs/sq.ft. ftz ft 0.3 Bed3
Default(8 Ibs/sq.ft. ftz ft 0.3 Kitchen
Default(8 Ibs/sq.ft. ftz ft 0.3 Living
Default(8 Ibs/sq.ft. ftz ft 0.3 Bath
Default(8 lbs/sq.ft. ftz ft 0.3 Pantry
Default(8 Ibs/sq.ft. ftz ft 0.3 MWic
Default(8 Ibs/sq.ft. ftz ft 0.3 MBath
Default B Ibs/s .ft. ftz ft 0.3 Hall
Name: Tina M Neace Signature:
Rating Compant: Tina M Neace Date: 08-14-18
8/14/2018 11.49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*=96
The lower the Energy Performance Index, the more efficient the home.
1.New home or,addition 1. New(From Plans) 12.Ducts,location&insulation level
a)Supply ducts R 6.0
2.Single-family or multiple-family 2. Single-family b)Return ducts R 6.0
c)AHU location Attic/Attic
3.No.of units(if multiple-family) 3. 1
4.Number of bedrooms 4. 3 13.Cooling system: Capacity 24.0
a)Split system SEER 16.0
5. Is this a worst case?(yes/no) 5. No b)Single package SEER
c)Ground/water source SEER/COP
6.Conditioned floor area(sq.ft.) 6. 1382 d)Room unit/PTAC EER
e)Other
7.Windows,type and area
a)U-factor:(weighted average) 7a. 0.330
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.280 14.Heating system: Capacity 24.0
c)Area 7c. 104.1 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8.Skylights c)Electric resistance COP 1.0
a)U-factor:(weighted average) 8a. NA d)Gas furnace,natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace,LPG AFUE
f)Other
9.Floor type,insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood,raised(R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a)Electric resistance EF 0.97
b)Gas fired,natural gas EF
10.Wall type and insulation: c)Gas fired,LPG EF
A.Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. 13.0 e)Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. f)Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 1061. 13.0
2.Masonry(Insulation R-value) 10132.
16.HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans Yes
a)Under attic 11 a. 38.0 b)Cross ventilation No
b)Single assembly 11b. c)Whole house fan No
c)Knee walls/skylight walls 11 c. d)Multizone cooling credit
d)Radiant barrier installed 11d. Yes e)Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code,Energy Conservation,if not DEFAULT.
I certify that this home has complied with the Florida Building Code,Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip: Zephyrhills, FL 33540
8/14/2018 11:50:19 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Q� ti
p
��\�' PI:O,fllUfl f
City of Zephyrhills ��Yt�
BUILDING PLAN REVIEW COMMENTS
r j �
Contractor/Homeowner: LJ
Date Received: rp
Site: 90 3 67----
Permit T le- 6,11
Type:
Approved w/no comments:❑ Approved w/the below comments: ( Denied w/the below comments: ❑
a
This comment sheet shall be kept with the permit and/or plans.
Kalvin Swi z Plans Examiner Date Contr tar an or eowner
(Required when comments are present) .
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Monday, September 10, 2018 9:50 AM
To: Jacqueline Boges
Subject: [Request received] 5901 13th St by#20205
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/238548
.................................................................................................................................................................................................................................................................................................................................................................................
Et Jacqueline Boges
-- Sep 10, 6:50 AM MST
5901 1 3th st by#20205 water meter
This email is a service from City of Zephyrhills Support .
1