Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-20558
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20558 RESIDENTIAL SWIMMING POOL PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20558 Address: 6601 SILVERADO RANCH BLVD Permit Type: SWIMMING POOL RES. ZEPHYRHILLS, FL. Class of Work: POOL/NEW Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVERADO Est. Value: Parcel Number: 05-26-21-0070-00300-0030 Improv. Cost: 49,500.00 OWNER INFORMATION Date Issued: 12/07/2018 Name: DOBSON, BRANDON & BRITTANY Total Fees: 570.00 Address: 6601 SILVERADO RANCH BLVD Amount Paid: 570.00 ZEPHYRHILLS, FL 33541-2547 Date Paid: 12/07/2018 Phone: 813-758-4396 Work Desc: INSTALL SWIMMING POOL CONTRACTORS APPLICATION FEES OLYMPUS POOLS BUILDING FEE 435.00 HAWKINS SERVICE COMPANY PLUMBING FEE 67.50 OLYMPUS POOLS ELECTRICAL FEE 67.50 I � I Inspections Required POOL STEEL POOL DECK& FOOTER POOL ELECTRIC BOND POOL PLUMBING/PRESSURE FINAL REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the, local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." CONTRACTOR PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF " NOTICE " / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT# THIS JOB HAS NOT BEEN COMPLETED, The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR DUKE - ENERGY WR#29.774298 September 10- 2018 Olympus Pools --4422 N Lauber Way ... Tampa,FL,33-614 813-983-7854 . teatonolympus@gmail.com Subject: 6601 Silverado Ranch Blvd , Dear Olympus Pools: Thank you.for.contacting Duke Energy Florida,:LLC. for a letter of no conflict regarding your pool construction. NO CONFLICT: Duke Energy Florida, LLC has reviewed our existing:facilities at the above referenced address and has-found no apparent conflict at the.proposed-pool'location. .According,.. . .. .. tathe drawing(s) you have provided Duke Energy Florida,-LLC-:has no objection to the proposed construction. Note: Florida law requires excavators to dial Sunshine State One Call of Florida at 811 to locate .. existing underground utilities prior to d,iggirigto avoid personal:injuryand damage to:equipment. .; Sincerely,: Lillian Marcano Project Coordinator Duke Energy Florida,LLC 2501 25th St N,St.Petersburg,FL 33713 1 ►►ii►►i►►i►►ii►i►►►ii►►i►i► ►i►i i►►►i i►►u►►i►►i►i►i►►i►►ii► 2018166242 Rcpt: 1994326 Rec: 10.00 NOTICE OF COMMENCEiVIENT DS: 0.00 IT: 0.00 Prrrnit No. 10/01/2018 K. D. K. , Dpty Clerk _ Ir1r H u•rJt.tt .Pi, 11 HHSCO CLERK K GUMP1'ROLLER Property Identification No. ' -5 - ( ' C(�7C7 'L � - [i(JjC. 10/01/2018 11:23am 1 of 1 OR BK 9795 PG 3104 T11F.UNDERSIGNED hereby- sires notice that iutprovemenis will be made io certain real properly.and in accordance Nt ith Section 711.13 of the Florida Statutes. the followinu information is provided in the NOTICE OF CO.N. C'VNIENEMENT 7 6 S��( 1. _S1kjyx-e' L,_ 41 3• }'Y 16J3 a) street Address: I' U-�re,c1- t j( ?. IN GROUND POOL K SPA.DECK..SCREEN ENCLOP.E 3. Owner information a► Name and address: 1.)('C�c��Y1 Dt.:�JSc�rJ r`i(r� ( S%�UEre•a�e1 (�s4-r^c� l ��.,'��,�=iJ` r`�i�l�S 3 b) Nanie and address ut'fee simple titleholder(ifutlier than L)wiivr) e) Interest in property -I. Contractor Information a) Nianie and address: J.AMES STATEN DUA OLYMPUS POOLS INC 4.122 1J LAUBER YVAY TAr,4PA.FL 33614 b) Telephone No.: 813-83-7854 Fax No. (Opt.) 81 3-8 7 3 482'1 5. Surely Information a) Name and address: NIA b) Arnonnt of Rond: NA c) Telephone No.: NIA Fax No. t Opt.) NiA 6. Lender a) Name and address: NIA 7. identity of person within the State of Florida designated by owner upon whom notices or other documents may be served.- a) Name and address: NIA b) Telephone No.: NIA Fax No. (Opt.) NIA S. In addition to himself. owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 71 3.13(1)(b).Florida Statutes: a) Name and address: NA b) Telephone No.: NIA Fax No. (Opt.) NA 9. Expiration date of Notice of Commencement(the expiration date is one vear from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PA,'1\iENTS MADE BY THE OWNER.AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT.ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART 1,SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TRICE FOR iPROVEMENTS TO YOUR PROPERTY-.A NOTICE OF COMMENCEMENT MUST BE RECORDED.AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING.CONSULT YOUR LENDER OR AN ATTORNEY BEFORE. COMMENCING NVORK OR RECORDING YOU NOTICE OF C III NC'ENIEN'r. STATE OF FLOW COUNTS'OF PAS Notary Public State of Florida 5 notrre OF Owner or Owner's Authorized 001cer Direclor P:iriner.'hL•m:Igcr Dianne Caban My Commission GG 164440 4 y) ro Y�rD a Expires 11/30/2021 Prins Na re The f0regoina instrument wag ncknoivledu•d brl'urc ne this dm'0, / 'f1 ,bN as e of r �:'tTf trustee.attlnney in fact)f' (name ul'party in1 behalf o- Thom is. rtunent as esevute I. Per-zonally Kno sir_OR Produced 1<denti(ivatiun Notary Signattur Type of ldentitication PI.OdUced L.,64u,11� Dame(print) Veriticalion pursuard lu Beckon 92.525. I:luridil SWILnes. t;nderpenalties ofperiur•.I declare that 1 halve read ncc lloreizoing and 111:11 the 1"WIS slated in i1 ar:Irtw to the be t r l'nr. L.rn .Ir•'e,:;u111.b:li:l I STATE OF FLORIDA,COUNTY OF PASCO IS TO CERTIFY THAT THE. REGOING IS A _ � ' ' TRUEAND CORRECT COPY OF TOHE DOCUMENT r N FILE OR OF PUBLIC RECORD IN THIS OFFICE In fost•"We?rust ' �' TN SS MY HAND A D FF CIAL SEAL THIS DAY OF � 4c`4 . Z_"""19 CL RK&COMPTROLLER BY DEPUTY CLERK From Hawkins Eleiric 1.813.322.8345 Fri Dec 7 09:26:00 2018 MST Page 1 of 1 v IIra�,W&v 1ri[y oT cepnymws I-ertnli Application Fa*813-740a21 Building Department Date Received Phone Contact for Permitting Owner's Nams ( /��C3�CTY� O �-1 Owner Phone Number Owners Address owner Phone Number Fee Simple Titleholder Name Owner Phone Number Poe Simple Titleholder Address f JOB ADDRESS 6—w( Sj WE� p4) i1 bj- LOT# SUBDIVISION PARCELID# 05%X s2l f 07b G030D (5630 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CON ADDIALT SIGN Q DEMOLISH ® INSTALL 8 REPAIR PROPOSED USE Q SFR Q COMM © OTHER I I^M-Llt .'ialiNZRO TYPE OF CONSTRUCTION Q 8 iLOCK Q FRAME u STEEL Q DESCRIPTION OF WORK { a ! {a+ / f BUILDING SLM SQ FOOTAGE= HEIGHT ILDINCi $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY © W.(i.E.C. =PLUMBING Q a� MECHAhiICAL S VALUATION OF MECHANICAL INSTALWTi []GAS ROOFING © SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ j V. FEE cuR6 Y J N Address I Kir "r , �( 7e O r License# ELECTRICIAN SIGNATURE REGISTERED 1 7,/ NPEE CURREr. LILN Address �e PLUMBER`'� V COMPANY SIGNATURE t REGISTERED __yt7 Nej FEE CURRE11 Y/N Address di Mf�e License# COIC ' ------------ MEClfICAI. COMPANY Si8 REGISTERED Y/ N FEE OUR RFJ.C( jL• •�N� ��, .''� - iS ow 36" C License# OTHER 7 COMPANY r SIGNATURE REGISTERED I YIN FE&CURREA Y! Add noss License# RESIDENTIAL Attach(2)Plot Plans:(2)sets of Building Plans;(1)set of Energy Forms;R-O"W Permit for new construction, o 1 o-I ou-uucu Ully OT Lt)Pnyff III IS r-Uf f f l l I.IAPPI ICdLIUI I Building Department Date Received /� � Phone Contact for Permitting Owner's Name l J, 6!^r S6-1— O S(,-VJ Owner Phone Number �) 3 �J O 7 ✓�� Owner's Address 17 t 81LJ- ' Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6�//v( <', 41 9A_iIzil/1 LOT# SUBDIVISION Sal a4h' PARCEL ID# 05 , O oo?o 0300 0030 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED X NEW CONSTR ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER G LJd TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL EZ DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE HEIGHT ILDING $ (� VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ ( AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATIO(P =GAS ROOFING = SPECIALTY = OTHER 3�D �(— -7 FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED I Y/ FEE CURREN I Y/N Address T FZ 33(�Y License# PC ELECTRICIAN SIGNATURE ` REGISTERED / N FEE CURREN Y/ Address l� Icense# PLUMBER U COMPANY 40 SIGNATURE �� REGISTERED I Y N FEE CURREN Y/N AddressZ.I 10 le, License# (::7 C -- MEG'fl74iQi�CAL __ COMPANY - - St6 l - -- - —- �� - —'- REGISTERED _ Y/ N -FEE CURRE�' Y/N Qi Address — --" - - ---- - L'icense# OTHER COMPANY SIGNATURE REGISTERED Y/ N_j FEE CURREN Y/N Address I License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, NOTICE OF DEED RESTRICTIONS:.The undersigned understands that this permit may be subject to"deed"restrictions" ¢ which may be more restrictive than County regulations. The undersigned.assumes responsibility for compiiancewith any; applicable de,ed.restrictions., - UNLICENSED CONTRACTORS AND CO-NTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contraddrs to.undertake work;they maybe required to be licensed.in accordance with state land.local regulations: If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation understate law. ,if the owner or intended'contractor are.uncertain as to what licensing requirements may apply for the' intended work,they are advised to contact the Pasco County-Building Inspection Division—Licensing Section at 727-847- 8009: ,Furthermore, if.the.owner has hired"a contractor or contractors, he is.advised to have the coritractor(s)'sign portions of the"contractor Block"of this application for-which they- ill be responsible. if you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting.•privileges in Pasco County,. TRANSPORTATION IMPACT/UTIL}TIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and.Recourse-Recovery Fees may apply to the construction of new buildings,change-of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89707 and.. 90-07,;as-amended.-The undersigned:also.understands;that such flees,as may-be due,will-be identified at the time of permitting. It is,further understood that Transportation Impact Fees_and Resource Recovery Fees must be.pald.prior to receiving a"certificate of occupancy"or final power release. If the;project does not involve a certificate of occupancy or final power release,-the fees must be paid prior to permit issuance. Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN L;AW-(Chapter 713,Florida Statutes,as amended):.:If valuation of work is$2,500.00 or more, I certify;that 1, the applicant;,have been provided with a copy of the "Florida Construction Lien Law.—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver;it to the"owner"prior to commencement. CONTRACTOWSIOVWNEWS AFOIOAVIT:1.1 certify that all-the information in this application is accurate and that.all work will be'done In compliance with all applicable laws regulating.construction,zoning and land development. Application is herebyi made to obtain a permit to da work and installation as indicated. 'I certify that no work or installation.has commenced.prior to issuance of a permit and;that all work will:be.performed to meet standards,of all laws regulating construction, County and City codes, zoning regulations, and land development regulations In the jurisdiction. I also certify that I understand that the regulations of other government agencies mayapply to the Intended work,and'thdfit is my responsibility to identify what actions I must take to be In compliance. Such agencies Include but are not limited to: Department of Environmental.Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,WatedWastewater Treatment: Southwest Florida Water Management District-Wells, Cypress. Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Englneers-Seawalls,Docks;Navigable Waterways. ' Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US'Environmental ftection-Agency-Asbestos abatement. 1 Federal Aviation Authority-Runways. I understand that the following restrictions apply-to the use of fill: Use of fill`is not allowed in-Flood'Zone"V"unless expressly permitted. If the fill material is to be.used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating-volume"will be submitted at time of permitting which is prepared by a professional engineer.. licensed by the State of Florida. If the fill material-ls10:be used-in.Flood Zone "A" in connection with a permitted building using stern wail construction,-I certify-that fill will be used only to fill the area within the stem wail. If fill material is to be used ln-any area, I certify that use of such fill will not adversely affect adjacent properties' If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under,the attached permit application,for lots less than one(1) acre which are'elevated,by'fill;anerigineered drainage.plan is required: If-I am the AGENT FOR THE-OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this•affidavit_prior to commencing construction. I understand that a-separate permit may be required for electrical work, plumbing, signs,wells;pools;'air conditioning, gas, or other Installations not specifically included in the application. A permit issued shall be construed to be a license to.proceed with the work and not as authority to violate,cancel,alter,.or• set aside any provisions if t ie technlcal codes,no shall issuance"of a permit prevent the Building Official from thereafter requiring a correction-of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless,the.work authorized,by.such permit is commenced within six months of permit issuance,or if work authorized by the periiilt is suspended or abariddned far a period of six(6)months.after the time the work is,commenced. An extension ' may berequested, in writing,from the:Building.Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.-ifwork ceases for-ninety(90)consecutive:days,'the job is considered abandoned. WARNING.,TO,OWNER:- YOUR FAILURE;TO RECORD A;NOTICE OF COMMENCEMENT.MAY RESULT IN YOUR PAYING 79i4lIdE FOI2'iNfPI20NEMENTS'TO.j iD. k'Pi20PEi2TY.;'IF,YOU;tNTEND`T0 OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNt Y BEFORE RECORDING YOUR:.NOTICE-OF COMMENCEMENT.' FLORIDA JURAT'(F.S.117.03)" OWNER OR AGENT CONTRAC,T,O Subscribed and sworn to(or affirmed)before me this bscribe an sworn t atfirme ) efore me is > by _ .... �bY� { Who Ware personally known to me or hasthave produced o tst re personate o to ma or has/have produced asidentification. ����� as identification. Notary Public /�hT('I//L/ &Notary Public Commission No. mission No. Name of Notary typed,printed or stamped Name of Notary typ ,ed rinted or s +U4 t:u ,commission GG 0453 43 ,r.�,=Expires November 7,2020 fr;?i+t;;;:,- Bonded ThNTroyFainlNurenoslinmWo1l p PLEASE RECYCLE r- ._- License #CPC1458348 2License #CPC1 4158502 0 U Olympuspoolsfl COm: Quolity Construction,[xcepfional Service " This agreement is made on this date of acceptance by Olympus Pools,Inc.,herein.termed"Contractor"or"Seller"and the party named:below, .. herein termed"Owner"or"Authorized Buyer"Reference simultaneously made to both"Contractor"and"Owner"are herein termed the"Parties°::. NAME:: /fV�/ �6�Gr�Y"Q0� ::�6�Sdol� DATE:' f J06 ADDRESS: !A(O4/ �L dEY 'U h9!� CITY: Z1.e�ICl�ll1- STATE: f�L . ZIP: 33 // r TELEPHONE:(H) . (C)_; �- ���J `� P� (FAX) .E-MAIL: L�/' ����L�//t/� /�I�YG.I�t�. : SUBDIVISION: INDICATE WITH IN ALL:SPACED ITEMS INCLUDED IN CONTRACT,IF NOT INCLUDED LEAVE BLANK. ❑ Automation: Pool Related Permits:arid-Drawings: Pool Structure.:.::.. ❑..Child Fence ❑ N/A �'l Olympus D.By Owner: :. " - With (1) LED light,Main Drain,Skimmer, Filter, Plumbing, 0 Child.F. ce LF:. Structure to Meet or Exceed Building Code Requirements. ❑ Retaining Wall:. Dimensions: x -�2 -❑ NOTES :width le th ::.. Depth: ft.x ft I P Gu 6, 7rt L shallow . -.:deed Coping Type: 71",Ae 0 e�� �A7WA Deck Type: s0 �&''` Total SQ FTG:' Top'existing.Ratio,With Footers ❑ Door Pads Qty: ❑,: Footer:Dimensions. x x ....... ❑ :Screen . ❑ One Story ❑:Two Story Dimensions: . x Doors: ❑White ❑ Bronze `.,29SPA-includes 6.Hydrotherapyjets, Blower, 12"Elevation: .. 24" Spillway,Spa light ❑White ❑ LED eatingectric ❑ LP Gas ❑ NatGas ❑ Solar %.ell-RTY OF TT "City of Pure Water" 5335 Eighth Street•Zephyrhills,Florida 33542-4312 (813)780-0000 •Fax (813)780-0005 GENE WHITFIELD November 15,2018 Mayor CITY COUNCIL Mike Lawson Dune FL Land I Sub LLC LANCE A.SMITH C/O Metro Development Group, LLC Council President 2502 N.Rocky Pont Drive,#1050 Tampa,FL 33607 KENNETH M.BURGESS,JR. Vice President RE:Pool and Screen Enclosure Setbacks in Silverado Ranch Subdivision CHARLES E.PROCTOR Dear Mr. Lawson, W.ALAN KNIGHT This letter serves as the City's determination of setbacks for pools at the Silverado Ranch Subdivision. This information was not clearly spelled-out in the approved JODI WILKESON PUD agreement for Silverado Ranch. Pools shall be a minimum of ten(ten)feet from edge of water to the rear lot.line, while the deck shall be a minimum of five(5)feet from the rear lot line. Full STEVEN F.SPINA screen enclosures shall be a minimum of five(5)feet from the rear lot line. City Manager Please let me know if you have further questions or comments. LORI L.HILLMAN City clerk,CMC Thanks, MATTHEW E.MAGGARD City Attorney To Vande Berg Director of Planning TV/rvc CC: File Bill Burgess,Building Official Matt Maggard, City Attorney C O�o /�5�' ILOf71UH City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: A0 AG, Date Received: Site: �(�� �S/Z�/�/'(��D ZV7C4 Permit Type: y1, Approved w/no comments: ; Approved w/the below comments: ❑ Denied w/the below comments: ��v4 V1 �Xn Z 0 -L S�4-(iQ 0-- Q Of This comment sheet shall be kept with the permit and/or plans. Kalvin Sv4itzer P s Examiner Date Contractor and/or Homeowner (Required when comments are present) AP5P/AN5►-I5 FLOW CALCULATIONS PER STANDARD. POOL WATER VOLUME 1,M10 /360= 20 GPM CALCULATED FLOW RATE.NOTE POOLS UDDER 13000 GALLONS.THE CALCULATED FLOW RATE OR 36 GPM WHICHEVER IS GREATER = THE FILTRATION FLOW RATE IS THERE AND AUXILIARY LOAD ON THE FILTRATION PUMP? Y IF SO.WHAT I5 THE CALCULATION AUXILIARY FLOW RATE. 12 GPM MINIMUM FLOW RATE 72 GPM(GREATER OF THE FILTRATION FLOW RATE OR THE AUX FLOW RATE IF THE AUX FLOW RATE IS POWERED BY THE FILTRATION PUMP) APSP/ANS►-7 ALL LISTED BELOW PIPING IS FOR FILTRATION PUMP ONLY THIS DATA IS FOR THE POOL MINIMUM SUCTION PIPING SIZE 0 6 FPS 2 MINIMUM SUCTION BRANCH PIPE O 8 FPS 2 SINGLE UNBLOCKABLE? Y TWO OR MORE?N MINIMUM RETURN PIPING SIZE O 6 FPS 2 MINIMUM RETURN BRANCH PIPE O 8 FPS 2 (IF SINGLE UNBLOCKABLE INDICATE MAKE AND MODEL NINEER) FILTER TYPE AND SIZE.200 SF CARTRIDGE DRAIN MAKE AND MIODELI.AaJASTAR 32 CNANFEL MINIMUM FILTER AREA PER FILTER FACTOR IN STANDARD 200 X 375= 15 GPM LISTED COVER FLOW RATE. 316 GPM (MAXIMUM FLOW THOUGH FILTER FACTOR. FILTER AREA X.375(CART).X 2(DE)OR X 13(SAND) SYSTEM FLOW RATE. 130 GPM BACKWASH VALVE.Y (IF YES,MUST BE 2'MINIMUM) METHOD DETERMINING FLOW RATE. MAX FLOW FROM PUMP CURVE PUMP SELECTION AS LISTED ON CURVE A (A= (THAN 11.000 GAL OR C= >THAN IIOOI GAL) PUMP MAKE AND MODELP,HAYWARD TRISTAR SPS245OVSP PUMP MAKE AND MODELS,HAYWARD TRISTAR VARIABLE SPEW 5P5245OV5P SUCTION PIPING. FLOW RATE 24 GPM 150 RPM(FLOW RATE MUST BE t OR = MAX FILTER FLOW RATE) BRANCH PIPING SIZE 3 INCH O 6 FPS OR LONER PUMP CONTROLS= FILTRATION PUMP HAS NO AUX LOAD-STANDARD TIME CLOCK TRUNK PIPING SIZE 9 INCH 0 8 FPS OR LONER FILTRATION PUMP NTH AUXILIARY LOAD-CONTROL MODEL FOR LOW SPEED DEFAULT WITH 24HR PUMP HEATER MAKE AND MODELS.140K HEAT PUMP GAS HEATER EFFICIENCY RATING: (NO PILOT LIGHT) HEAT RUMP EFFICIENCY C.O.P..63 EQUPMENT PIPING-MINIMUM 4 PIPE DIAMETERS IN FRONT OF THE PUMP AND MINIMUM 18'AFTER FILTER FOR FUTURE SOLAR(DIRECTIONAL RETURN FITTINGS POLL BE INSTALLED) _______________________________________ LL 0 JOB SITE SPECIFICATIONS IMMIf4J P�(„ PLAN FOR: DRAWING ITEMS REV1510NS. 4222 N.LAUBER WAY L°T,, BLOCK.3 BRITTANY $ BRANDON DOB5ON DATE.7-2o-Is TAMPA,FL 33614 SUBDNISION. SILVERADO RANCH SW ORDER 8 215 9 240 6601 SIL VERADO RANCH BLVD DRAWN BY.N p y PHONE. 813-483-7854 PLAT BOOK.13 PAGE:54-65 PLAN» 164450-153 cwNTM. PASco ZEPHRYHILLS, FLORIDA 33541 SHEET. 2 OP 2 IO'LF.OF 12 RAISED POOL BEAM W/(2)2FT SHEER DESCENT WATERFALLS LF.OF 6'RAISED-7L - [ POOL BEAM TYPICAL EACH SIDE - � CONCRETE FOOTING 1 / ALONG EDGE FOR y� OVERFLOW SCREEN ENCL. INL �► _ _ ii -3'6' F R 32'LONG FR 1i IO' I 0 5bP I �. SPECS: T I = SIZE.4'-6"X � SPA SPECS: INL D SKIM VAC \�Ii I EPTH: s' v __ ____ ______ — — — — PERIMETER: d3 SIZE. 6'-6'X8' 61 I AREA.304 DEPTH: 3' I III VOLUME: 7140 PERIMETER: 24 TURNOVER: 6 R.MIN.(25 GPM 1 LOW SPEED) AREA. 52 II I TOP EXISTING 6 X 4'-6'SUN5HELF/15T I I I PATIO IN PAVERS rPOOL STEP W/BUBBLER KITCHEN COPINGS 6-X 12'TRAVERTINE VOLUME. 475 II I AREA TILE. 6' TURNOVER. 12 MIN. I III ( SKIMMER: I SPILLWAY. 5'-0' RETURN-.3 WALL•2 FLOOR THERAPY JETS: 6 III 16'SWIMOUT WITH DOOR/WINDOW VAC LINE: YES COLOR TILED EDGE L�� ALARMS AS NEEDED LIGHT. 121/LED. I III SELECTOR LIGHT: I-121/LED. SWITCH ENTRY STEP: NO SWIMOUT. 18' RAISED: 12'PEDESTAL11 RE51 DEI`CE FINISH. QUARTZ POOL EQUIPMENT SHALL RAILINGS. NO j POOL BE SCREENED IF REGID. PATIO: BRICK PAVERS EG JIP BY LOCAL CODE ENCLOSURE. YES FOOTERS. YES DECK-O-DRAIN. IF NEEDED i ? 51JNSHEI-FAST STEP PV BUBBLER TOP EXISTING PATIO W/PAVERS EGXJIPMENT SPECS: PUMP: SP9245OVSP NAYWARD TRISTAR VAR.SPEED FILTER. 6200 HAYWARD CARTRIDGE CHLORINATOR. HAYWARD SALT HEATER. IOOOOO BTU HEAT PUMP BLO ER. I POOL PLAN AUTOMATION: NO Z SCALE. I/6' • 1'-0' 4 I W IL JOB SITE SPEGIFiGATION5 SWIMMING POOL PLAN FOR: DRAWING ITEMS REVISIONS. / DATE:1-20-18 // P 4222 N LAl1BER WAY LOT'3 BLOC 3 BRITTANY BRANDON DOB5QN 5118DIVISION: SILvlRADO RANGN Sue ORDER�275•240 TAMPA.FL 33614 6601 5IL VERADO RANCH BL VE2 DRA BY=N p PHONE: 813-4163-1854 FLAT BOOK:73 PAGE:54-05 PLAN 6 UW430-153 ZEPHRYHILL5, FLORIDA 33541 SHEET. I of 2 tmuron.eawasarwev COUNTY: PASC.O _ = [y to w . e _ Ii I / Gar $ 64 ? w . IflN _ �, , w 1 v a * O ç0 / • . O .... tlt s 1 3) V. , ,e N . ' - . - - - - . : ______ "o«8 L7 l FLORIDA BUILDING CODE R4501 SPECIAL SPA REQUIREMENTS: c FLOW THRU SPA SKIMMER REQUIREDN. NO SKIMMER FOR SPA WrIH THE POOL CONTRACTOR IS RESPONSIBLE FOR -MAXIMUM WATER DEPTH 4',MAXIMUM SEAT DEPTH TYPICAL OR.FOR#3 3 INDEPENDENT FURNISHING ALL DETAIL DESIGN REQUIREMENTS 28",MAX, SKIMMER REBAR,P OUI WITH FILTRATION SYSTEM FOR EACH INDIVIDUAL POOL IN ACCORDANCE WITH -FLOOR SLOPE 1:12 #8 CU TO PUMP THE FLORIDA BUILDING CODE,AND ALL -STEPS:MIN.TREAD 10"X 12",7"MIN.RISER,12"MAX. O o CONSTRUCTION SHALLf ALL APPLICABLE RISER EXCEPT THE BOTTOM STEP MAY BE 14"IF IT IS �•1 g' Q OPTIONAL DECK WI CODES AS PIPING IP SHALL BEL�SCH.40 PVC,NSFELECTRICAL PW MAX TI US�ORM 7 THE SPA ILS OPERATED TREADS RISERS TO a) N t14"1'rc IN to .,..� CA PRESSURE VELOCITY 10 FPS,SUCTION 6 FPS. INTERMITTENTLY IT SHALL HAVE A ONE HOUR • �� � �OPII THE POOL PLAN SHALL SHOW THE DESIGN TURNOVER,IF CONTINUOUS A SIX HOUR TURNOVER. I`I OPTIONAL 12V LIGHT PLUMBING AS PER THE SAMPLE WITH THE MAXIMUM'IEMPERATURE 104 DEGREES. OR�SEE NOTES) INFORMATION REQUIRED SHOWN. MAIN DRAIN -MEET ANSI/NSPI ARTICLE XVII,SAFETY z NO LIMITATIONS TO PLUMBING SHALL BE TWO DRAINS SEPARATED BY 3' o oC INSTRUCTION/SAFETY SIGNS. � � � � F SHAPE EXCEPT FOR WITH APPROVED ANSI/ASME A112.19.8.2009 COVERS.AS -PRESSURE TEST PIPING AT 35 PSI FOR 15 MINUTES OR W AN ALTERNATE THE APPROVED DRAINS MAY BE MEET LOCAL CODE IF GREATER. j • DIVING STEPS OPTIONAL PLACED ON DIFFERENT PLANES.THE TWO DRAINS II 4 O SHALL HAVE A COMMON SUCTION LINE SUCTION 0 y' O vi • GRATES MAY BE USED IF APPROVED AT A MAXIMUM GENERAL DESIGN REQUIREMENTS - CIRCULATION >MAIN DRAIN RF.QULRE OF 1)2 FPS AND THE SUCTION PIPING IS RECESSED *"� Q) ENTRY REQUIRED (TAMPER PROOF/SEE NOTES) Fr SWIM-OUT OR LADDER (SEE NOTES) LINE FROM THE GRATE THE DISTANCE EQUAL TO THE -DESIGN,CONSTRUCTION AND WORKMANSHIP "O R REQUIRED( C >LIGHTING&BONDING SAME AS SUCTION PIPE SIZE.SKIMMERS DO NOT REQUIRE SHALL BE IN CONFORMITY WITH THE WHERE D>ip121 OVER POOL PROTECTION AND REQUIREMENTS OF APSP/ICC 3,APSP/ICC 4,APSP/ICC 5, M ; S DEEP(SEE NOTES) >NO LiMITATTONS ON SHAPE MUST BE DESIGNED FORA MINIMUM 25 gpm. AND APSP/ICC 6 AND APSP/ICC 7 BASED ON THE 1+,+ THE FOLLOWING SHALL BE LABELED WITH POOL TYPE RAIL OPTIONAL GENERAL SPA PLAN LABEL MAIM TAPE AT THE FILTER LOCATION: ' -SEE NSPI FOR DIVING WATER ENVELOPES. 1""I GENERAL POOL PLAN PIPES,VALVES,PUMP(S)OFF SWITCH. -SLIDES SHALL INSTALLATION REQUIREMENTS. UFACfURE'S N.T.S. N.T.S. ALL POOLS WHETHER PUBLIC OR PRIVATE SHALL BE . ELECTRICAL REQUIREMENTS: PROVIDED WITH A LADDER OR STEPS IN THE SHALLOW END WHERE THE WATER DEPTH EXCEEDS 24 INCHES(610 2 9"Mir EXCWI'FOR IN SEE NSPI5 RE: -WIRING AND BONDING AND ALL ELECTRICAL TO FEET(1524 MM)THERE SHALL BE LADDERS,STAIRSOR 5 O SLOPING BNTRIE3.4'1u'Max HANDHOLDS COMPLY WITH CHAPTER 42,FLORIDA BUILDING CODE UNDERWATER BENCHES/SWIM-OUTS IN THE DEEP END. G pR�A1�,NG NO OUTLET OR OVERHEAD POWER WITHIN 10'IF UDENTIAL AND NEC 2014. SEDI( ,,BENCHES OR SWIM-OUTS ERE MANUFACTURED SHALL BEST IS OR ApLY'4 " WITHIN 15'PROTECT BY GFI,TRANSFORMER MIN.10' LOCATTID IN A CORNER. WATER-1 $H�",CO 1NG Q00 ' + FROM POOL, TO A I,8"ABOVE WATER, BO WHI(RCIIO V�IS -�CULATION SYSTEMS,COMPONENTS AND •�t '03 pRK gV1A \ OR EQUIPMENT SHALL COMPLY WITH NSF 50. • FLOATSB �t1NSTAII EDIF Y 8"Mix p g FLpREG'( "�� 0/Qx �O • FIRST EXCEPT WHERE PVC IS APPROVED.• �TERS SHALL TURNOVER AN AIR RE EASE;AOND • LESSTHANaa- Radios N . �pn"PTV PRESSURE GAGE 1. _ (O 0 V -PUMPS 3 HP AND LESS SHALL MEET ANSLUL1081 t CIE e w. s CO BQOu�FD( SISTA WITH STRAINER AND MEET (f) 3 Mar. ORO V• �c `1�{�� SAMPLE ONLY.EACH APPLCATION FOR PERMIT SHALL -SURFACE SKIMMERS SHALL MEET NSF 50 AND 0 1 -J,`1� ZLp `w��P� BE BASED ON A TOTAL DYNAMIC HEAD OF 60 R OF SURFACE AREA NE FOR EVERY 800 SQUARE FEET >r Mir TO SLOPE CHANGE ♦ G mme�" System ow Rate: APPROVED MANUFACUTRED INLET FITTNG3 FOR THE .� �i G G Minimum Flow Rate Required:35gpm per skimmer(Required:I S uiner per 800 at) • RETURN OF RECIRCU(AT ED POOL WATER SHALL BE • POOL SECTION DETAIL Q�.P' - PROVIDED ON THE BASIS OF AT LEAST ONE PER 300 Pool Volume: .500 sq.ft x 4 ave depth x 7.481 gal/cf= 15,000 gallons SQUARE FEET(28 m2)OF SURFACE AREA.SUCH INLET N.T.S. Turnover Time in Hours:6 hours x 60 min/hr= 0 minutes FITTINGS SHALL BE DESIGNED AND CONSTRUCTED TO Flow Rate: 15.000 gallons! 360 minutes= 47 gpm INSURE AN ADEQUATE SEAL TO THE POOL STRUCTURE AND SHALL INCORPORATE A CONVENIENT MEANS OF SEALING FOR PRESSURE TESTING OF THE POOL • SB2836,6-20-07 • CIRCULATION PIPING.WHEN MORE THAN ONE INLET IS • FOR BONDING AND GROUNDING SYSTEMS FOR SWIMMING POOLS,THE USE OF REQUIRED,THE SHORTEST DISTANCE BETWEEN ANY TWO • AN UNDERGROUND BONDING CONDUCTOR MADE OF#8 AWG.BARE SOLID PIPE SIZING CHART(MAXOMUN) • REQUIRED INLETS SHALL BE AT LEAST 10 FEET(3048 MM). COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW PEPE i PRESSURE •MAIN DRAINS AS OF 12-19-06 -HEATER SHALL MEET ANSI-221.56 OR UL 1261 OR SUBGRADE,AND 18 TO 24 INCHES FROM INSIDE WALL OF A SWIMMING POOL OR ANSI/ASME A112.19.8-20x7 UL 559. • SPA,IS DEEMED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO COMPLIANCE 114' 35 GPM 65 c I • -DISINFECTANT EQUIPMENT SHALL COMPLY WITH WITH s.680.26(c)OF THE NATIONAL ELECTRICAL CODE 2" 60 105 NSF 50. 214 90 147 -PRESSURE TEST PIPING AT 35 PSI FOR 15 MINUTES OR -135 230 PAVERS OR q 235 396 IL POOL MEET LOCAL CODE IF GREATER. 4"DECK 2,R : -RESIDENTIAL SWIMMING BARRIER REQUIREMENTS TO • FOOTING DECK FINISH MIN.GRATE OPEN AREA-FLOW/17.8 • MEET SECTONS 454.2.17 OPTIONAL psi(M'°•)CONC. PER CONTRACT FOR Pools WITH VOLUME-15,000 GALS. FOR VELOCITY 6'/SEC -WASTE DISPOSAL TO COMPLY WITH SECTION 454.2.10 W/FIRER MESA (NON-SLIP) PUMP:STARrMPWADLORHAYWARD SUPERIT .I i V • R HP 42 GPM 6a TURN • CLEANER IT HAS BEEN CERTIFIED THAT THESE DESIGN • LINE REQUIREMENTS ARE IN COMPLIANCE WITH THE # Da�B TURNOVER RATE-6 ROURS-360 MINE. REQ FLORIDA BUILDING CODE R4501,6TH EDITON 4542-2017, 8" POOL FINISH FILTEIL 1 I�50.50c��AcrrY •® ANSI/APSP/ICC 3, PHR FINISHc1 MAIN DRAIN: ARD 0751,ARD 761018E ANSI/APSP/ICC 4,ANSI/APSP/ICC 5,AND ANSVAPSP/ICC 6 AND Date:Janus 1,2018 8"X 8"FOOTING BEAM'rRAP MIEANR: :HAY D VAC LOC ANSI/APSP/ICC 7,ANSUAPSP/ICC 14,ANSVAP3Pacc 15. Drawn by: MJT 8 W/(2)#3 BARS ONAL OR(1)#5 BAR 64 4' MARCITEOR EXPOED 6"Min.WALL&FLOOR THICKNESS.3,500 psi(MIN.)CONC.#3 BARS ON AGGREGATE S MAIN SUCTION PIPE SIZE�,"_ '2" V"CENTERSRAGEONHER STEELW/COL ASTMA15.Al Y,TIE ALT.INTERSECTIONS 15'AS R SUCTION PIPE SIZE OLYMPUS POOLS Structural subject to suitable soil conditions. CL.EANER/VAC PIPE SIZE 1 " EQUIPMENT RESIDENCE POOL/SPA, DECK, BEAM, WALL, FLOOR it LOCATION N.T.S.