Loading...
HomeMy WebLinkAbout18-20581 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20581 BUILDING PERMIT PERMIT INFORMATION' LOOAMON INFORMATION Permit Number: 20581 Address: 591,GALL BLVD Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: NEW CONST/COMM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 10-26-21-0020-00000-0090 Improv. Cost: 303,211.92 OWNER INFORMATION Date Issued: 12/14/2018 Name: ZEPHYR II LLC Total Fees: 3,950.24 Address: 7162 READING RD STE 730 Amount Paid: 3,950.24 CINCINNATI OH 45237-3845 Date Paid: 12/14/2018 Phone:,. Work Desc: BUILDOUT PIZZA HUT ( �'ti lCC' ' CONTRACTORS APPLI ATION FEES OSAGE CONTRACTORS LLC BUILDING FEE 433.40 AEC ELECTRICAL CONTRACTORS LLC ELECTRICAL FEE 94.50 J & S PLUMBING INC PLUMBING FEE 63.00 UNITED SHEET METAL &AIR CONDITI MECHANICAL FEE 163.80 SEWER CONNECTION RESIDENTIAL 1,306.50 WATER CONNECTION RESIDENTIAL 416.65 WATER METER 1.5 1,415.63 �! FIRE PLAN REVIEW FEES 56.76 �v ns ections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIdIATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER �1 YA�nt on- Pizza Hut 1,892 sq ft-51 Gall Blvd Column SO. FEET PRICE MAIN OR LIVING: 1,892 $ 160.26 M IIB OTHER•AREA UNDER ROOF: $ 88.00 OTHER: - $ - VALUATION $ 303,211.92 FEE SHEET $ 1,140.00 ADDRESS $ 30.00 DRIVEWAY1 $ 45.00 BUILDING: $ 433.40 ELECTRICAL: $ 94.50 PLUMBING: $ 63.00 MECHANICAL: $ 163.80 SUB-TOTAL $ 754.70 TOTAL $ 754.70 SEWER: $ 1,306.50 13 occ load WATER: $ 416.65 IRRIGATION: $ - TOTAL: $ 1,723.15 WATER METER: $ 1,415.63 1.5' IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 56.76 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 56.76 PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: $ - SUB-TOTAL $ 3,950.24 PARK IMPACT FEES n/a SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - n/a T I F'S: $ 25,322.53 applying for fee to be waived CRA District 9 $ 25yO69.30 1 1% 253 $ 253.2323 TOTAL: $ 29,272.77 \ i + T tt City of Zephyrhltls PermftAppl cation' Fuats) 1 1�1�L/KRj C� Ila9lkV DIP 3m.rl I i Dab Racdvad — P acontsatfwP.lrrilm 1 913" 3 706 - 865 _ OrrtaraNalw NPCintemalionel omm(vnm.NumtW 013,322?5555 Owns.Addmw 7:i00 W.12Bth.1r_C.lt Ovadand Drk.K§g§2131 OmrorPbm.Number I FnSleOb TllNaoldar H.au 0. rPhane Numbw j -Fa S1mpM Tl3atwld.r j JGBADORE33 5Ga513Go�evard ZE rnGs FL33542 LOTS c� 511i�tY61QV PARCEL iW i D 26 21 0020 00000 0100." la.TADMI FAW nape"TAX MM!9) i A/ WORK PROPOSED NEWC0L`Lsm ' REPAIR ® SIGN Q Q OEb!d.RSM .AV{yam IVSTN.L 8 REPAIR PROFOSEn ISE [a SFR [,] COMA ® OTHER I TqnOrAI TYPE OF COIBTRIIMN Q BLOCK Q FRNAE Q srsrL Q E�s(�Qq ghell �, X\ DIMCRaana!OPWORx Tenant finish tor now deU"N1carrrcutPtzzaXIA •WALDINSWE C�6OF-00YAOS 1,892SF HEOHT i QeaaLlidvc is"� VALwnoNOFTOTALCONa-ICTION $140.000 QEiECTRICAL 1—. —J AMP SEWCE Q PROGRESS OZRGY Q W.'F-Q QPLUNaIroG ��—J QtdE(l�AtacPl L(S—,__J VALUATK)N OF NECVAWAL ULSTN.IATIou QGAs Q ROOOOF—IN—O�Q' wEcw.TY Q oncR MASHED FLOOR FJEVATK)NS �� FLMDZONEAREA AYES FK) f (�I rO 5ggb CAA yQ40r5 LL-G SIGNNATAT COMPANY I URE gf66aQlF9 Yt N F[i faMftl � addr.® a ax ZZ a��Y„cr Ito G i L lmnT.e CR L 125 qSZ 9 ELECTIMAN COAL-ANY �G •Ele��;[,1 L re-rgo{oY, SIGNATURE trcwrtxan _Yr N T'irsa s�. T rN Add Yq �, at'G( FJ -i lkansas G 13©a6o 5x PLUNMER i-�o11PAW Qlkrtb_t\BIGNATtm , Rat1LSICaaO YIN � YIN Addy.., �Azt .saX S -t4 FL I.)meuee FG PyZR2y;�� reECHAIacAL couPANr u+.44 f�e bl� 4 A1:r Car�(ir. :9 r�tnL SlGN0.1VRa: omrrnm Y N vaa pwap, fN Addwas S CanityL'tvrS�/a „ L rcl{t�d�F'C Lxmnee 19 ; OTHER COMPANY Oro"Um mama Ha YIN N.F aewe;. I YIN��" Aadrow Lkaraae i lfttlttftttttttttt telftatftt tftat•f tf ttfttelitattTtftttttfltt Tt�(fft .REUOENTL{L rUMu IZ)pal Pt.nN(T)aW of DaacSiy Pico.;(11 actor Fylciyy Fomn;R-0•W F'enM forrww crosavabtL Iran'mamlrn(1$)Y+or�q dryt atlxabblNttal dale,fL.Q.eted anaYd,CrasLllclbn Pmv.Sbmma'St Pfam wrSd Fareo salad• 3mluy F&M a fl 1 lts np c Sto Wort Pialit for c0l&tn%u*y P.*:s COMMFRC•AL ,mmeh(z)coTgi.taaaa of Mang Plarm pal.a Ur.S.fAy Pop;(1)Nl of En*W Fame•RO-W Prml krr Ia=4vjm L NkYawmt.n(13)woMap dqa afar aaWsical6vo.RDgad�oT9U.Cemataam P�Ae,SsmlwxxPbm YUSR FeIo.�•slYbed, Santpy FadFYAi 6 t tkanprien Sto Wak PaarA roe b 111HpICbCh,At Cm'.atrdal tegiaemenh must mptme .SIGN PERMIT .A'Ldl(2J earn td En(itrt+ad Pleat. '-7RCPERIY t.UfiYeY is9ur.d for as NEW mwft&on. Dtrettlof •.a.i.d� .-tom+-i-.-L-1'6'aa'+' Fla bw amkitson aear�pwdy. l Omer&tbllSaew-4n bark cf apcfjmbm rAwzw vom$ttM a Notk.of Ccnwn n m.ntl.roWbu4. (Atl opprodm over t:TE0o1 - AC.rtlrar tha a.w.aaq or Pony aLAmrtcY imr ore o.rtw),w�2dwsonwoae.anemtan:.d Namriom o.n.ra,Vioehtea.Ear 1 OVER TT@ COUNTIM PERAO M (copy of mfftd ratA" Rwoots a FYn(Fa so $—i[ I."mdaa AF Fwms(WASta WFoblape) Drh"t&v&-Mkt oars CoaLUr r on PuNb rw#Al -retods ROW i I a"V OWN wm X-S. L LI C. P.O. Bax 226 Buckner MO 64016 (816) 650-5580 Fax (866)720-3919 August 24,2018 City of Zephyrhills Building Department 5335 8 h Street Zephyhills,FL 33542 RE: Authorized Persons for Permit Pick up To whom it may concern, Please be advised that either Andrew Frye of Robert Howard are authorized to pick up permits. Sincerely, Adam M Project Manager Osage Contractors,LLC ti li MARIE 8 Y Notary f ublic-Notary Seal STATE OF MISS OURI commissioned for Cass County My commission Expires:August 21.2022 Commission#18506968 � i 1 i I t 1 t Jacqueline Boges From: Gail Hamilton Sent: Tuesday, August 28, 2018 8:41 AM To: Jacqueline Boges;B Subject: Sunrise Eatery 'u=burgess; Kalvin Switzer; Steve Spina i Hut TIF Jackie CRA approved waiver of all transportation impact fees for both projects.Will ask Jessica to provide minutes of meeting to you for your records. If I need to provide any additional information just let me know! Thanks Gail Gail K Hamilton City of Zephyrhills CRA Director (813)780-0202 1 COMMUNITY REDEVELOPMENT AGENCY MEETING A Regular Community Redevelopment Meeting was held on August 27,2018 at 5:00 p.m.in the Meeting Room of the Zephyrhills Public Library. CRA Board Vice President Proctor called the meeting to order. Roll call was taken. Present were members Charlie Proctor,Ken Burgess,Alan Knight,and Jodi Wilkeson. Mayor Gene Whitfield was absent. Councilman Lance Smith arrived at 5:02 p.m. City Manager Dr. Steve Spina and City Attorney Matthew Maggard were also present. Staff present: CRA Director Gail Hamilton,Utilities Director John Bostic,Director of Planning Todd Vande Berg,Building Official Bill Burgess,IT Director Mike Panak,HR Director Sandra Amerson,Airport Manager Nathan Coleman,Main Street Coordinator Anna Stutzriem,Historic Preservation Officer Audrey McGuire,Utilities Mike Barnes,Kristen Labbe with CliftonLarsonAllen(CLA)and City Clerk Lori Hillman. Ken Burgess moved to approve the minutes of the June 25,2018 Regular Meeting of the CRA. Seconded by Alan Knight. Motion passed unanimously. Charlie Proctor requested an emergency item be added to the agenda. Alan Knight moved to approve adding an emergency item to the agenda. Seconded by Ken Burgess. Motion passed unanimously. BUSINESS ITEMS This item was moved to this place on the agenda. 1. Transportation Impact Fee Waiver Request-Sunrise Eatery CRA Director Gail Hamilton presented a transportation impact fee waiver request for Sunrise Eatery. Ordinance#1309-16 provides the CRA Board the ability to waive or reduce transportation impact fees. Developers wishing to have Transportation Impact Fees reduced or waived,shall petition the CRA before beginning construction. All petitions shall be submitted in writing and shall describe the new development,state how the new development furthers the goals of the CRA,and how the new development is consistent with the CRA Master Plan. The impact fee as calculated by Building Official,Bill Burgess,totals$46,883.13. City Manager Steve Spina stated that ordinance#1309-16 would need to be reviewed to include criteria for each business and to have a proper procedure in place. Ms.Hamilton stated that Mr.Ayer has been working on redeveloping Zephyr Plaza before ordinance.#1309-16 came into effect,working under the criteria of ordinance#1003-08 where all transportation were waived. Alan Knight moved to approve Business Item 1 based on the criteria of ordinance#1003- 08. Seconded by Lance Smith. Motion passed unanimously. This item was moved to this place on the agenda. _ _ �,—,Tfansportation•Inpact-Fee Waiv`eiReqeusf=Pizza-HurTake`Out-Express CRA Director Gail Hamilton presented a transportation impact fee waiver request for Pizza Hut Take Out Express. Ordinance#1309-16 provides the CRA Board the ability to waive f?r reduce transportation impact fees. Developers wishing to have Transportation Impact Fees (reduced or waived,shall petition the CRA before beginning construction. All petitions shall be (submitted in writing and shall describe the new development,state how the new development Ji ,Airthers the goals of the CRA,and how the new development is consistent with the CRA Master Ran. The impact fee as calculated by Building Official�Bi11.Burgess;,totals$29 272-02- jKen Burgess moved to approve Business Item 2 based on the criteria of ordinance#1003- 08-Seconded=by.Lance Smith:=:Motion passed=unanimously;`-`- This item was moved to this place on the agenda. 3. FY2018/2019 Community Redevelopment Agency Budget CRA Director Gail Hamilton presented the FY 2018-2019 Community Redevelopment Agency Budget. The CRA's increment has doubled for both County and City contribution to the Trust Fund. This year's budget funds grant programs and projects for the district while keeping COMMUNITY REDEVELOPMENT AGENCY MEETING A Regular Community Redevelopment Meeting was held on August 27,2018 at 5:00 p.m.in the Meeting Room of the Zephyrhills Public Library. CRA Board Vice President Proctor called the meeting to order. Roll call was taken. Present were members Charlie Proctor,Ken Burgess,Alan Knight,and Jodi Wilkeson. Mayor Gene Whitfield was absent. Councilman.Lance Smith arrived at 5:02 p.m. City Manager Dr. Steve Spina and City Attorney Matthew Maggard were also present. Staff present: CRA Director Gail Hamilton,Utilities Director John Bostic,Director of Planning Todd Vande Berg,Building Official Bill Burgess,IT Director Mike Panak,HR Director Sandra Amerson,Airport Manager Nathan Coleman,Main Street Coordinator Anna Stutzriem,Historic Preservation Officer Audrey McGuire,Utilities Mike Barnes,Kristen Labbe with CliftonLarsonAllen(CLA)and City Clerk Lori Hillman. Ken Burgess moved to approve the minutes of the June 25,2018 Regular Meeting of the CRA. Seconded by Alan Knight. Motion passed unanimously. Charlie Proctor requested an emergency item be added to the agenda. Alan Knight moved to approve adding an emergency item to the agenda. Seconded by Ken Burgess. Motion passed unanimously. BUSINESS ITEMS This item was moved to this place on the agenda. 1. Transportation Impact Fee Waiver Request—Sunrise Eatery CRA Director Gail Hamilton presented a transportation impact fee waiver request for Sunrise Eatery. Ordinance#1309-16 provides the CRA Board the ability to waive or reduce transportation impact fees. Developers wishing to have Transportation Impact Fees reduced or waived,shall petition the CRA before beginning construction. All'petitions shall be submitted in writing and shall describe the new development,state how the new development furthers the goals of the CRA,and how the new development is consistent with the CRA Master Plan. The impact fee as calculated by Building Official,Bill Burgess,totals$46,883.13. City Manager Steve Spina stated that ordinance#1309-16 would need to be reviewed to include criteria for each business and to have a proper procedure in place. Ms.Hamilton stated that Mr.Ayer has been working on redeveloping Zephyr Plaza before ordinance.#1309-16 came into effect,working under the criteria of ordinance#1003-08 where all transportation were waived. Alan Knight moved to approve Business Item 1 based on the criteria of ordinance#1003- 08. Seconded by Lance Smith. Motion passed unanimously. This item was moved to this place on the agenda. 2. Transportation Impact Fee Waiver Request—Pizza Hut Take Out Express CRA Director Gail Hamilton presented a transportation impact fee waiver request for Pizza Hut Take Out Express. Ordinance#1309-16 provides the CRA Board the ability to waive or reduce transportation impact fees. Developers wishing to have Transportation Impact Fees reduced or waived,shall petition the CRA before beginning construction. All petitions shall be submitted in writing and shall describe the new development,state how the new development furthers the goals of the CRA,and how the new development is consistent with the CRA Master Plan. The'impact fee as calculated by Building Official,Bill Burgess,totals$29,272.02 Ken Burgess moved to approve Business Item 2 based on the criteria of ordinance#1003- 08. Seconded by Lance Smith. Motion passed unanimously. This item was moved to this place on the agenda. 3. FY2018/2019 Community Redevelopment Agency Budget CRA Director Gail Hamilton presented the FY 2018-2019 Community Redevelopment Agency Budget. The CRA's increment has doubled for both County and City contribution to the Trust Fund. This year's budget funds grant programs and projects for the district while keeping f CRA Meeting August 27,2018 Page Two funds available for additional projects or incentives to create development or redevelopment opportunities for the CRA District. -Residential Improvement Program -Fagade Improvement Grant -Paint Grant -Neighborhood Improvement Program -Residential Fagade Grant -Neighborhood Beautification Program -Homeownership Grant -Curb Appeal Project -Commercial Grant Program -Gateway Signage -Sign Grant Projects funded by other departments for the CRA District: -Flower pots for downtown—Partnering with Public Works,flower pots will be installed on 5`h Avenue from 9"'Street to 7`h Street. We hope to continue the effort down 8`h Street to the Library,if funds and manpower permit. -WI-FI—The CRA is working with Mike Panak in the IT Department to install equipment for free WI-FI in the downtown along 5`'Avenue from 9`h Street to 7`h Street. -Wireless Speaker System—The CRA is also working with the IT Department to obtain cost for the installation of wireless speaker system downtown on 51h Avenue between 10'h Street and 7`h Street. The system can be used daily with music to help create enjoyable atmosphere downtown and can be used at events and parades. Lance Smith moved to approve Business Item 3. Seconded by Jodi Wilkeson. Motion passed unanimously. 4. Matching Fagade Rehabilitation Grant—Taco Rico CRA Director Gail Hamilton presented a commercial fagade grant application for Taco Rico for$2,000 for the installation of a metal awning. The awning is a welcome addition to Taco Rico and allows shade area for customers as they wait to order or during bad weather.Taco Rico is one of the city's success stories;the owner started his business from a food truck and was so successful that he looked for location in Zephyrhills to open a brick and mortar store. Total cost of the improvements is$4,280. The CRA will reimburse Taco Rico$2,000. Lance Smith moved to approve Business Item 4. Seconded by Ken Burgess. Motion passed unanimously. Emergency Item placed here. Termite Treatment for 38453-38445-38439-38435 5`h Avenue CRA Director Gail Hamilton presented termite treatment assistance for Hudgins Law Finn,Manolo's,Going Postal,and Four to One Barbershop. They are requesting help in funding the cost of termite treatment for the entire building. The entire block is infested with termites and for the treatment to be effective,the entire block must be tented. The owners have received estimates for work from$15,000 to$28,000. This does not include the cost of closing businesses for the weekend to treat the buildings. The CRA and the Historic Preservation Board do not provide funds for termite treatment. The owners are requesting the CRA provide up to $5,000 for the preservation of the building stock in downtown. This is one,if not the most, historic set of buildings in the downtown. Councilman Smith recommended the$5,000 be paid directly to the vendor. Lance Smith moved to approve Emergency Item up to$5,000 maximum and those funds be paid directly to the vendor with a limit of 90 days for completion. Seconded by Jodi Wilkeson. Motion passed unanimously. 5. Main Street Report Main Street Coordinator Anna Stutzriem addressed the CRA Board with current Main Street activities. Music and Motorcycles is coming up September 15,2018,and Main Street has $1,500 more in sponsorships this year than in previous years and up 30 vendor spaces as well. Halloween Howl,Veteran's Day parade,and Festival of Lights all coming up in the next few months. CRA Meeting August 27,2018 Page Three 6. CRA Director's Report CRA Director Gail Hamilton stated the Code Enforcement Task Force will meet in the next few weeks to plan the Fall attack with neighborhood clean-ups. Planning,Public Works, and CRA departments will be meeting next week to look at grant opportunities for the coming year. CRA will be looking at opportunities and a priority list for sidewalks within the district. CRA continues to work on the design standards,the project is about 90%finished,a few more items need to be added before it is reviewed by the Planning department. Since July,the CRA has met with 7 potential businesses,and 10 potential residential investors. Utilities and the CRA continue to work together on plan to address issue of homes within the CRA using septic tanks instead of City sewer system. The CRA department has met with the owner of the Bargain Warehouse and talked to him about creating a plan to clean the building up,replacing the roof, building painted,and get it back open to the public. It is currently being used as a warehouse which is not allowed in the downtown. He has one month left to complete the work. Councilman Burgess spoke with Representative Danny Burgess and he has met someone who was involved with the renovation of the Tampa Theater and the gentleman is interested in looking at the downtown Home Theater. Ms.Hamilton stated that she had talked with Representative Danny Burgess and has passed the information on to the owner Mr.Balaska who is very interested. Mr.Balaska has painted his building and working on fixing the exterior to make it more appealing. City Manager Steve Spina stated the Florida Redevelopment Association is having a conference in October 2018. The City of Zephyrhills Planning staff will be putting on two sessions,Citizen Satisfaction Survey and Partnering Amongst Departments. Meeting Adjourned 5:58 p.m. Pizza Hut 1,892 Sqft Column Es SQ. FEET PRICE MAIN OR LIVING: 1,892 $ 160.26 Type IS Business OTHER AREA UNDER ROOF: $' 88.00 OTHER: - $ - VALUATION $ 303,211.92 FEE SHEET $ 1,560.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,671.20 ELECTRICAL: $ 351.00 PLUMBING: $ 234.00 MECHANICAL: $ 163.80 SUB-TOTAL $ 2,420.00 Public Fee 1% $ 24.20 TOTAL $ 2,444.20 SEWER: $ 1,306.50 13 occ load WATER: $ 461.65 IRRIGATION: $ - TOTAL: $ 1,768.15 WATER METER: $ 1,415.63 1.5 inch IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 56.76 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 56.76 PUBLIC SAFETY IMPACT FEES OL CE $ 48 68 \\� I E 1. V 5% $V 4"194 TOTAL: $ 852.37 SUB-TOTAL $ 6,537.11 PARK IMPACT FEES SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 25,322.53 99% $ 25,069.30 1% $ 253.23 TOTAL: $ 31,859.64 F ':a13 2013212918 I Iilllllllllllhllll. ,..,,.;. .. :r;. ..r 41: pwcdlnmo Pormill NO. NOTICE OF COMMENCEMENT d FkrWa COJNY of POW County ;5AUN,T=hwm=notice that ant VAII be made to certain red proporly.and In woordarm vhlh ChoplarIT13,Fbft a is ad In dfi Nottt:��� 1. Description d Property.Parcel Iderdill0allon No. Street Address: 5697Ga1 BLVD.,Zophyttillis,FL 33542 2. General Description at knpwmnwd Interior Tenant roM to Pim Net DelfftrylCorry Out Rcpt;2024317 Rae: 10.00 DS: 0.00 IT: 0.08 12/18/2018 K. D. K., Dpty-Clerk & owner Wormatlon or Lessee infoundort If the Losses conlrocted W the Improvement MIC International Name mxma� Fftbury KA Address CiW State Interest In PmWr. R2=of Fee Simple Tdleholdw. NIA Ut cIfferant ftm Owner 19W above) Address city FEW,- 4. ControoW. j�dc M—M 9 Buckner. MO Address city Cw*actesTelcpfmneNo-- 8198505580 PAULA S.OINEIL,Ph.D.PASCO CLERK & COMPTROLLER fi. SLUW WA 12/18/2018 12:410M 1 of I Name OR BK 9833 - PG 2875 Ad" city State Ammd of Band:S, Telephone No.: S. Lrbr. NIA Name Address citir state Landecs Telephone No.: 7. Persons witNo the Stela of Florida designated by the owner upon wham notices or.other documents may be served as provided by Section 713.13(i)(a)(7),Flaida Statutow Bait swvtmz Name 9203 Brady Street Spmg HIM Fl. -7 Address city TolephanaNumborofDosilptatodPonsm 9. In add Lion to Idmsetf fine owner dasigrtales WA of_ to receive a copy of the LWWs Notice as provided In Section 713.13(1 Xb),Florida Statutes, Telephone Number of Person or Entity Desoustod by Owner. P. Fxplrdon date of Nafte of Commencement(Ow a*Vakn data may not be before Me oompl"of construction and*0 psyment to the coritractDr.but Wit be one year ftrn ft date cf recording unless a different dads is speciflod): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER QIAPTER711�PART 1, SECTION7113.13 FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YO R PROPERTY: A NOTICE'or COMMENCEMOt MUST BE J";11 RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMME RK OR RECORDING YOUR NOTICE OF COMM6kEWW ' I declare that I have read the f of and did the facts stated we b to fine bast my parlay, OW,L M W. KIMBERLY E.HOWELL wature of or I assee or Owners or Lessees Autiorized MY COMMISSION P G0216478 'ryOP EXPIRES:May 10,2022 Sl Too/office /U The foregoing InaUumant was acknowledged before M��dq 20-(3by el alf er.trustm attorney in fact)for ps 0. Ptsonally Known CI DH ProduDod Identificaffionrer, Notary 17-7-7:M:: �'3�t"e� Type of Idwff"tion Produced Name(Prial) Scanned by CamScanner City of Zephyrhills Water and Sewer Impact Fee Calculation Land Use Type: Restaurant (A) Conventional No. of Seats Impact Fees For Type A Within City Limits Outside City Limits Water Distribution System $ 416.65 $ 520.81 Wastewater Collection System $ 837.47 $ 1,046.83 Wastewater Treatment Plant Capacity $ 469.03 $ 586.29 TOTAL $ 1,723.15 $ 2,153.94 (B)Fast Food/Drive Through No. of Seats Impact Fees For Type B Within City Limits Outside City Limits Water Distribution System $ - $ - Wastewater Collection System $ - $ - Wastewater Treatment Plant Capacity $ - $ - TOTAL $ - $ - (C)Deli/Sandwich Shop with no dishwasher and disposable dinnerware only No. of Seats i Impact Fees For Type C Within City Limits Outside City Limits Water Distribution System $ - $ - Wastewater Collection System $ - $ - Wastewater Treatment Plant Capacity $ - $ - TOTAL $ (D)Bakery No. of Square Feet Impact Fees For Type D Within City Limits Outside City Limits Water Distribution System $ - $ - Wastewater Collection System $ - $ - Wastewater Treatment Plant Capacity $ - $ - TOTAL $ - $ - Florida Building Code,, Sixth Edition. (2017).- Energy Conservation Energy.Gauge Summit@)Fla/Conn-2017, Effective Date:Dec 31, 2017 ASHRAE 90.1-2013- Prescriptive Compliance Option Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: ® This Checklist The full compliance report generated by the software that contains the project summary,compliance summary,certifications and detailed component compliance reports. The compliance report must include the full input report generated by the software as contigous part of the compliance report. Boxes appropriately checked in the Mandatory Section of the complaince report. "c y V_? O p , fl � IN e"w�wu:,waF. EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective.Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 1 of 21 PROJECT SUMMARY Short Desc: Pizza Hut Description: Pizza Hut Owner: NP —�� Addressl: 69 53 GALL BLVD. City: Zephyrhills Address2: _ State: FL Zip: 0 Type: Dining:Family Class: Renovation to existing building Jurisdiction: ZEPHYRHILLS,PASCO COUNTY,FL(611600) Conditioned Area: 1828 SF Conditioned&UnConditionedArea: 1828 SF No of Stories: 1 Area entered from Plans 1829 SF Permit No: 0 Max Tonnage 0 If different,write in: EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 2 of 21 Compliance Summary Component Design Criteria Result ENVELOPE PRESCRIPTIVE PASSES LIGHTING POWER 1,104.0 2,144.6 PASSES LIGHTING CONTROLS PASSES EXTERNAL LIGHTING No Entry HVAC SYSTEM PASSES PLANT No Entry r WATER HEATING SYSTEMS PASSES PIPING SYSTEMS No Entry Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009-- — —An input report of this.design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 3 of 21 CERTIFICATIONS •i hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Building Official: Date: 7 Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law,I hereby certify(*)that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Randall A.Nelson Reg No: 65765 Lighting Designer: Randall A.Nelson Reg No: 65765 Mechanical Designer: Randall A.Nelson Reg No: 65765 Plumbing Designer: Randall A.Nelson Reg No: 65765 (*) Signature is required where Florida Law requires design to be performed by registered design professionals.Typed names and registration numbers may be used where all relevant information is' contained on signed/sealed plans. Project:Pizza Hut Title:Pizza Hut Type:Dining:Family (WEA File:FL_TAMPA INTERNATIONAL AP.tm3) Prescriptive Envelope Compliance Item Zone Description Design Criteria Meet Req. Project:Pizza Hut Title:Pizza Hut Type:Dining:Family (WEA File: FL TAMPA INTERNATIONAL AP.tm3) EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 4 of21 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (VV) (Sgft or ft) None Project:Pizza Hut Title:Pizza Hut Type:Dining:Family (WEAFile:FL_TA IPA INTERNATIONAL AP.tm3) Lighting Power Compliance Space Ashrae Description Area Height No.of Design Effective Allowance ID (sq.ft) (ft) Spaces (W) (W) (Vi) Lobby 12 Lobby(General)- 323 10.0 1 209 209 342 Reception and Waiting Restroom 6 Toilet and Washroom 82 12.0 1 45 45 80 Kitchen 7 Food Service-Kitchen 1,423 9.3 1 851 851 1,722 Design 1104(W) PASSES Effective: 1104(W) Allowance: 2144.57(W) Passing requires Design to be at most 100%of Criteria Project:Pizza Hut Title:Pizza Hut Type:Dining:Family (WEA File:FL TAMPA_INTERNATIONAL AP.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance Lobby 12 Lobby(General)-Reception and 323 3 1 PASSES Waiting Restroom 6 Toilet and Washroom 82 1 1 PASSES Kitchen 7 Food Service-Kitchen 1,423 2 1 PASSES PASSES EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 5 of 21 Project:Pizza Hut Title:Pizza Hut Type:Dining:Family (WEA File:FL_TAWA_INTERNATIONAL AP.tm3) System Report Compliance RTU-1 RTU-1 Constant Volume Air Cooled No.of Units Single Package System< 1 �cnnn ur.,n.r Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Conditioners Air Cooled 43 14.50 14.00 8.00 PASSES Single Pkg<65000 Btu/h Cooling Capacity Heating System Warm Air Gas Furnace< 80 81.00 80.00 PASSES 225000 Btu/h Air Handling Air Handler(Supply)- 1600 0.70 0.82 PASSES System-Supply Constant Volume RTU-2 RTU-2 Constant Volume Air Cooled No.of Units Single Package System< 1 64nnn Rti,n,r Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Conditioners Air Cooled 51 14.00 14.00 8.00 PASSES Single Pkg<65000 Btu/h Cooling Capacity Heating System Warm Air Gas Furnace< 75 81.00 80.00 PASSES 225000 Btwb Air Handling Air Handler(Supply)- 1600 0.70 0.82 PASSES System-Supply Constant Volume RTU-3 RTU-3 Constant Volume Air Cooled No.of Units Single Package System< 1 �cnnn ufi,n,r Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Conditioners Air Cooled 61 14.00 14.00 8.00 PASSES Single Pkg<65000 Btu/h Cooling Capacity Heating System Warm Air Gas Furnace< 75 81.00 80.00 PASSES 225000 Btu/h Air Handling Air Handler(Supply)- 1950 0.58 0.82 PASSES System-Supply Constant Volume PASSES EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 6 of 21 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV- H'LV liance None Project:Pizza Hut Title:Pizza Hut Type:Dining:Family (WEAFUe:FL_TAMPA_INTERNATIONAL_AP.tm3) Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance Water Heater 1 Gas Storage water >75000& 96.00 0.80 285.03 PASSES heater <=155000 BtLg4< 4000(Btu/h)/gal PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] [F] .SFJ9 - ti None EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 7 of 21 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted with permission Topic Section Component Description Yes N/A exempt 1.To be checked by Designer or Engineer rvu,m Insulation 5.8.1.2 Envelope Below-grade wall insulation installed per manufacturers€TMs instructions. Insulation 5.8.1.2 Envelope Slab edge insulation installed per manufacturers El El ❑ €TMs instructions. Insulation 5.5.3.5 Envelope Slab edge insulation depthAength. Insulation 6.4.4.1.5 Envelope Bottom surface of floor structures incorporating radiant heating insulated to>=R-3.5. Fenestration 5.5.3.6 Envelope U-factor of opaque doors associated with the building thermal envelope meets requirements. SYSTEM—SPECIFIC 6.5.1,6.5.1.1, Mechanical Air economizers provided where required(and not 6.5.1.3,6.5.1.4 exempted),meet the requirements for design capacity,control signal,ventilation controls, high-limit shut-off,integrated economizer control, and provide a means to relieve excess outside air during operation. SYSTEM—SPECIFIC 6.5.1,6.5.1.2, Mechanical Water economizers provided where required, El 0 El 6.5.1.3 meet the requirements for design capacity, maximum pressure drop and integrated . economizer control. SYSTEM—SPECIFIC 6.5.1.5 Mechanical Economizer operation will not increase heating ❑ ❑ El energy use during normal operation. SYSTEM—SPECIFIC 6.5.2.2.1 Mechanical Three-pipe hydronic systems using a common return for hot and chilled water are not used. SYSTEM—SPECIFIC 6.5.2.2.3 Mechanical Hydronic heat pump systems connected to a common water loop meet heat rejection and heat addition requirements. SYSTEM—SPECIFIC 6.5.1.6 Mechanical Water economizer specified on hydronic cooling and humidification systems designed to maintain inside humidity at>35 A°F dewpoint if an economizer is required. SYSTEM—SPECIFIC 6.5.3.1.1 Mechanical HVAC fan systems at design conditions do not El E exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM—SPECIFIC 6.5.3.1.2 Mechanical HVAC fan motors not larger than the first available El 0 motor size greater than the bhp. HVAC 6.5.6.1 Mechanical Exhaust air energy recovery on systems meeting El 0 El Tables 6.5.6.1-1,and 6.5.6.1-2. SYSTEM—SPECIFIC 7.4.2 Mechanical Service water heating equipment meets efficiency requirements. SYSTEM—SPECIFIC 7.5.2 Mechanical Service water heating equipment used for space heating complies with the service water heating equipment requirements. Insulation 5.8.1-2 Envelope Above-grade wall insulation installed per manufacturers€TMs instructions. Insulation 5.8.1.2 Envelope Floor insulation installed per manufacturera€TMs instructions. Controls 10.4.3 Mechanical Elevators are designed with the proper lighting, El Q ED ventilation power,and standby n lbde. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7a Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7b Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7c Mechanical Heat Rejection Equipment:Minimum Efficiency L1- 0 RequirementTable 6.8.1-7 EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 8 of 21 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7d Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM—SPECIFIC 6.5.5.3 Mechanical Centrifugal fan open-circuit cooling towers having combined rated capacity>=1100 gpm meets minimum efficiency requirement:Table 6.8.1-7 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7e Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7f Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7g Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7h Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7i Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM—SPECIFIC 7.5.3 Mechanical Gas-fired water-heating equipment installed in new buildings:where a singular piece of water-heating equipment>=1,000 kBtu/h serves the entire building,thermal efficiency must be>_ 90 Et. Where multiple pieces of water-heating equipment serve the building with combined rating is>=1,000 kBtu/h,the combined input-capacity-weighted-average"thermal efficiency,thermal efficiency must be>=90 Et Exclude input rating of equipment in individual dwelling units and equipment<=100 kBtu/h. 2.,To be checked by Plan Reviewer Plan Review 4.2.2,5.4.3.1.1,5.7 Envelope Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Plan Review 4.2.2,6.4.4.2.1, Mechanical Plans,specifications,and/or calculations provide 6.7.2 all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Plan Review 4.2.2,7.7.1,10.4.2 Mechanical Plans,specifications,and/or calculations provide all Information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Plan Review 4.2.2,8.4.1.1, Project Plans,specifications,and/or calculations provide 8.4.1.2,8.7 all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed.Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Plan Review 4.2.2,9.4.3,9.7 Interior Lighting Plans,specifications,and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Plan Review 9.7 Exterior Lighting Plans,specifications,and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations,wattage of bulbs and . ballasts,transformers and control devices. EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 9 of 21 Insulation 5.8.1.7.3 Envelope Insulation in contact with the ground has<=0.3% water absorption rate perASTM C272. Air Leakage 5.4.3.4 Envelope Vestibules are installed where building entrances separate conditioned space from the exterior,and meet exterior envelope requirements. Doors have self-closing devices,and are>=7 ft apart(>=16 ft apart for adjoinging floor area>=40000 sq.ft.). Vestibule floor area<=7 50 sq.ft.or 2 percent of the adjoining conditioned floor area. HVAC 6.4.3A.4 Mechanical Ventilation fans>0.75 hp have automatic controls to shut off fan when not required. HVAC 6.4.3.8 Mechanical Demand control ventilation provided for spaces 1-1 El >500 ft2 and>25 people/1000 ft2 occupant density and served by systems with air side economizer,auto modulating outside air damper control,or design airflow>3,000 cfm. HVAC 6.4.4.1.4 Mechanical Thermally ineffective panel surfaces of sensible heating panels have insulation>=R-3.5. HVAC 6.5.2.3 Mechanical Dehumidification controls provided to prevent 1:11:1 El reheating,recooling,mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. SYSTEM—SPECIFIC 6.5.3.1.3 Mechanical Fans have efficiency grade(FEG)>=67.The total ❑ ❑ El efficiency of the fan at the design point of operation<=15%of maximum total efficiency of the fan. SYSTEM—SPECIFIC 6.5.3.5 Mechanical Motors for fans>=1/12 hp and<1 hp are electronically-commutated motors or have a minimum motor efficiency of 70%.These motors are also speed adjustable for either balancing or remote control. SYSTEM—SPECIFIC 6.4.3.10 Mechanical DDC system installed and capable of providing control logic including monitoring zone and system demand for fan pressure,pump pressure, heating,and cooling;transferring zone and system demand information from zones to air distribution system controllers and from air distribution systems to heating and cooling plant controllers;automatically detecting and alerting system operator when zones and systems excessively drive the reset logic;allow operator removal of zone(s)from the reset algorithm;AND capable of trending and graphically displaying input and output points. SYSTEM—SPECIFIC 6.5.3.2.3 Mechanical Reset static pressure setpoint for DDC controlled VAV boxes reporting to central controller based on the zones requiring the most pressure.Controls provide:zone damper monitoring or indicator of static pressure need;autodetection,alarm,and operator override of zones excessively triggering reset logic. SYSTEM—SPECIFIC 6.5.3.3 Mechanical Multiple zone VAV systems with DDC of individual 1:111 El zone boxes have static pressure setpoint reset controls. SYSTEM—SPECIFIC 6.5.3A Mechanical Multiple zone HVAC systems have supply air temperature reset controls. " SYSTEM—SPECIFIC 6.5.4.1 Mechanical System turndown requirement met through multiple single-input boilers,one or more modulating boilers,or a combination of single-input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtu/h has 3:1 turndown ratio,boiler input between 5.0 MBtu/h and 10 MBtu/h has 4:1 turndown ratio, boiler input>10.0 MBtu/h has 5:1 turndown ratio. HVAC 6.5.4.2 Mechanical HVAC pumping systems>10 hp designed for variable fluid flow. SYSTEM—SPECIFIC 6.5.4.3,6.5.4.3.1, Mechanical Fluid flow shutdown in pumping systems to 1-1 ❑ 6.5.4.3.2 multiple chillers or boilers when systems are shut down. EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 10 of 21 SYSTEM—SPECIFIC 6.5.4.4 Mechanical Temperature reset by representative building loads in pumping systems>10 hp for chiller and boiler systems>300,000 Btu/h. SYSTEM—SPECIFIC 6.5.4.5.2 Mechanical Hydronic heat pumps and water-cooled unitary air 0 El conditioners with pump systems>5 hp have controls or devices to reduce pump motor demand. SYSTEM—SPECIFIC 6.5.4.6 Mechanical . Chilled-water and condenser water piping sized El ED 11 according to design flow rate and total annual hours of operation(Table 6.5.4.6). SYSTEM—SPECIFIC 6.5.5.2.1 Mechanical Fan systems with motors>=7.5 hp associated with heat rejection equipment to have capability to operate at 213 of full-speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM—SPECIFIC 6.5.5.2.2 Mechanical Multicell heat rejection equipment with variable-speed fan drives installed that operate the maximum number of fans allowed that comply with manufacturers specs and control all fans to the same fan speed required for the instantaneous cooling duty. SYSTEM—SPECIFIC 6.5.5.2.3 Mechanical NA HVAC 6.5.7.1.1 Mechanical Ktchen hoods>5,000 cfm have make up air 1:1 El El >=50%of exhaust air volume. HVAC 6.5.7.1.1 Mechanical Kitchen hoods>5,000 cfm have make up air >=50%of exhaust air volume. SYSTEM—SPECIFIC 6.5.7.1.2 Mechanical Conditioned supply air to space with a kitchen hood shall not exceed the greater of a)supply flow required to meet space heating or cooling,or b)hood exhaust flow minus the available air transfer from available spaces. SYSTEM—SPECIFIC 6.5.7.1.3 Mechanical Kitchen hoods with a total exhaust airflow rate >5000 cfm meet replacement air,ventilation system,or energy recovery requirements shown in Table 6.5.7.1.3. SYSTEM—SPECIFIC 6.5.7.1.4 Mechanical Kitchen hoods with a total exhaust airflow,rate >5000 cfm meet replacement air,ventilation system,or energy recovery requirements. HVAC 6.5.7.2 Mechanical Fume hoods exhaust systems>=5,000 cfm have VAV hood exhaust and supply systems,direct make-up air or heat recovery. HVAC 6.5.8.1 Mechanical Unendosed spaces that are heated use only El El 0 radiant heat. SYSTEM—SPECIFIC 7.5.1 Mechanical Combined space and water heating system not 11 El El allowed unless standby loss less than calculated maximum.AHJ has approved or combined connected load<150 kBtu/h. Controls 8.4.2 Project At least 50%of all 125 volt 15-and 20-Amp El El El receptacles are controlled by an automatic control device. Other Equipment 10.4.1 Mechanical Electric motors meet requirements where 1:1 El El applicable. HVAC 6.4.3.3.2 Mechanical Setback controls allow automatic restart and 11 El El temporary operation as required for maintenance. SYSTEM—SPECIFIC 6.4.3.3.3 Mechanical Systems with setback controls and DDC include optimum start controls.Optimum start algorithm considers mass radiant slab floor temperature. SYSTEM—SPECIFIC 6.4.3.3.4 Mechanical Zone isolation devices and controls. 1:1 0 Wattage 9.4.2 Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. 3To be checked by lnspector . EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 11 of 21 Insulation 5.8.1.7 Envelope Exterior insulation protected against damage, sunlight,moisture,wind,landscaping and equipment maintenance activities. HVAC 6.4.3.7 Mechanical Freeze protection and snow/ice melting system sensors for future connection to controls. Air Leakage 5.4.3.1 Envelope Continuous air barrier is wrapped,sealed, ❑ caulked,gasketed,and/or taped in an approved manner,except in semiheated spaces in climate zones 1-6. Air Leakage 5.4.3.2 Envelope Factory built and site-assembled fenestration and E _ doors are labeled or certified as meeting air leakage requirements. Fenestration 5.8.2.1,5.8.2.3. Envelope Fenestration products rated(U-factor,SHGC,and 5.8.2.4,5.8.2.5 VT)in accordance with NFRC or energy code defaults are used. Fenestration 5.8.2.2 Envelope Fenestration and door products are labeled,or a signed and dated certificate listing the U-factor, SHGC,VT,and air leakage rate has been provided by the manufacturer. -10 El SYSTEM—SPECIFIC 7.4.4.1 Mechanical Temperature controls installed on service water ' heating systems(<=120A°F to maximum temperature for intended use). SYSTEM—SPECIFIC 7.4.4.2 Mechanical Automatic time switches installed to automatically 1:1 El switch off the recirculating hot-water system or heat trace. SYSTEM—SPECIFIC 7.4.6 Mechanical Heat traps installed on non-circulating storage El El El water tanks. HVAC 6.4.1.4,6.4.1.5 Mechanical HVAC equipment efficiency verified.Non-NAECA El El El HVAC equipment labeled as meeting 90.1. SYSTEM—SPECIFIC 6.4.1.5.2 Mechanical PTAC and PTHP with sleeves 16 in.by 42 in. labeled for replacement only. HVAC 6.4.3.4.1 Mechanical Stair and elevator shaft vents have motorized El El ❑ dampers that automatically close. HVAC 6.4.3.4.2,6.4.3.4.3 Mechanical Outdoor air and exhaust systems have motorizedEl 1:1 ❑ dampers that automatically shut when not in use and meet maximum leakage rates.Check gravity dampers where allowed. HVAC 6.4.3.4.5 Mechanical Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50%or less of design capacity. HVAC 6.6.3.2.1 Mechanical DX cooling systems>=75 kBtu/h(>=65 kBtu/h ❑ 0 El effective 112016)and chilled-water and evaporative cooling fan motor hp>=A''Y4 designed to vary indoor fan airflow,as a function of load and comply with operational requirements. HVAC 6.4.4.1.1 Mechanical Insulation exposed to weather protected from damage.Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. HVAC 6.4.4.1.2 Mechanical HVAC ducts and plenums insulated. Where ducts ❑ or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC 6.4.4.1.3 Mechanical HVAC piping insulation thickness. Where piping is installed in or under a slab,verification may need to occur during Foundation Inspection. HVAC 6.4.4.2.1 Mechanical Ducts and plenums sealed based on static El 1:1 El pressure and location. SYSTEM—SPECIFIC 6.4.4.2.2 Mechanical Ductwork operating>3 in.water column requires air leakage testing. SYSTEM—SPECIFIC 6.5.2.1 Mechanical Zone controls can limit simultaneous heating and Q El ❑ cooling and sequence heating and cooling to each - zone. SYSTEM—SPECIFIC 6.5.2.2.2 Mechanical Two-pipe hydronic systems using a common distribution system have controls to allow a deadband>=15 A°F,allow operation in one mode for at least 4 hrs before changeover,and have rest controls to limit heating and cooling supply temperature to<=30 A°F. EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017—- Florida Building Code,Sixth Edition(2017)-Energy Conservation ASH RAE 90.1-2013-Prescriptive Compliance Option 7/6/2018" Page"12 of 21 HVAC 6.5.2.4.1 Mechanical Humidifiers with airstream mounted preheating ❑ jackets have preheat auto-shutoff value set to activate when humidification is not required. HVAC 6.5.2.4.2 Mechanical Humidification system dispersion tube hot 1:1 El surfaces in the airstreams of ducts or air-handling units insulated>=R-0.5. SYSTEM—SPECIFIC 6.6.3.2.2 Mechanical VAV fans have static pressure sensors positioned so setpoint<=1.2 in.w.c. design pressure. SYSTEM—SPECIFIC 6.5.4.5.1 Mechanical Two-position automatic valve interlocked to shut off water flow when hydronic heat pump with pumping system>10 hp is off. SYSTEM—SPECIFIC 6.5.6.2 Mechanical Condenser heat recovery system that can heat water to 85 A°F or provide 60%of peak heat rejection is installed for preheating of service hot water. HVAC 6.5.7.1.5 Mechanical Approved field test used to evaluate design air flow rates and demonstrate proper capture and containment of kitchen exhaust systems. SYSTEM—SPECIFIC 6.5.9 Mechanical Hot gas bypass limited to: <=240 kBtu/h W 15% >240 kBtu/h s€"10% HVAC 6.4.3.9 Mechanical Heating for vestibules and air curtains include El El El automatic controls that shut off the heating system when outdoor air temperatures>45F. Vestibule heating systems controlled by a thermostat in the vestibule with setpoint<=60F. Controls 6.5.10 Mechanical Doors separating conditioned space from the El 1:1 El outdoors have controls that disable/reset heating and cooling system when open. Controls 9.4.1.1 Interior Lighting Automatic control requirements prescribed in Table 9.6.1,for the appropriate space type,are installed.Mandatory lighting controls(labeled as 'REQ')and optional choice controls(labeled as 'ADD1'and'ADD2')are implemented. Controls 9.4.1.1 Interior Lighting Independent lighting controls installed per " approved lighting plans and all manual controls readily accessible and visible to occupants. Controls 9.4.1.2 Interior Lighting Parking garage lighting is equipped with required lighting controls and daylight transition zone lighting. Controls 9.4.1.1f Interior Lighting Daylight areas under skylights and roof monitors that have more than 150 W combined input power for general lighting are controlled by photocontrols. Controls 9.4.1.4 Exterior Lighting Automatic lighting controls for exterior lighting El 1:1 ❑ installed. Controls 9.4.1.3 Interior Lighting Separate lighting control devices for specific uses installed per approved lighting plans. Wattage 9.6.2 Interior Lighting Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Wattage 9.6.4 Interior Lighting Where space LPD requirements are adjusted 0 based on room cavity ratios,dimensions are consistent with approved plans. Insulation 5.5.3.1 Envelope Roof R-value.For some ceiling systems, verification may need to occur during Framing Inspection. Insulation 5.8.1.2,5.8.1.3 Envelope Roof insulation installed per manufacturers€TMs instructions. Blown or poured loose-fill insulation is installed only where the roof slope is<=3 in 12. El El Insulation 5.8.1.1 Envelope Building envelope insulation is labeled with ❑ R-value or insulation certificate has been provided listing R-value and other relevant data. Insulation 6.8.1.9 Envelope - Building envelope insulation extends over the full area of the component at the proposed rated R or U value. Insulation 5.8.1.4 Envelope Eaves are baffled to deflect air to above the insulation. Insulation 5.8.1.5 Envelope Insulation is installed in substantial contact with the inside surface separating conditioned space from unconditional space. EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Flodda.Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 13 of 21 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ � .. 0 ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ..O ' ❑ C] ova C N - o _ t7 E m m m •a° ° rn- m a c m •c vmi o o m -c vmi o e II o f5 ° « a > -q 0 E N om!Nv L=y° v�° CyEyU •?rn7? rna�. ?6t �vNLOO+.`�-�u1O''.q�Ei�Qy�ay ay.CN1� `od�oaaCf0 a•y�ay a�•cCyCN ooaVCaa�Upl E 0(avc>tNnD OL .na�OOOU• -m vcy ^ a °3 ° .05 Eco v od =f ° y ° ) oU.) > Qoc m c E yo _ o io - m4- L o � uN ora- Q ae > c n > 'n x ° W > E �° ° om O A„o d o m a� m NE 4C c � LL E u L d E a i u Eda a nE w i rn E o c S SSU mr d ° ' o aai c m 5 y -ffi ° oc E m E "o « a -o E cu N NE C ( N d .2ai W rG ! E N U � .0 JC O«x x ° N C 2 LE a) C O m ° _ -o vo ai a) E E m E ° w o o 'O V ° c ° ° -0!a p7d ` S � cu aO $ a0 m E - E - c0 O . r QS E ma - o� C yo c ° S- L a LL mQ n°a $ a n m o cN - li L0) IL f►VQ,¢ O Z 0 U) y ZE a a n a 8 8 8 8 8 8 8 8 O fU E 8 8 N U 0 0 0 o m m m m m m m m m m m m o m m m [{ �.� m m m > > > > 0 cLi c'ci o u 0 L) LL) cL) o a 0 •� cLi cLi cLi #-V �"�' o c'Li cLi � � C C C C m m a) a) m m m m a) a) a) a) m m a) a) a) a) Q ` W W W W C €' CL •d F" N N N C � C W o ) .� E T U v N P7 N c° f0 fM ' N fM cq LL 0 (M Ih Ci (7 M Ci Ci _ sh '? LR Lq Lq N M fh co N CV � ui ui LO ui to tc w w w w (D n n n 0) N. U w m 0 E W AD E 7 U U U U U U U U U U ? O U LL_ lL LL LL ILL LLLL LL LL LL_ F" - tU N W W W W W W W W W W a a a a a a a a a a 3 ' U to to to w to to to to to (n 3 3 U) I I I I I I I I I I a) m y A O 0 0 0 0 m 2 2 W W W W W W W 0) W W W U •O N Uf- > > > > rn Q Q Q coQ Q N to U U fA U to U c c C 7 c c c c } > > > } > o W m _ to x x x rn x x to to to W m 3 m U w j a a a m v LL � N Post Construction 6.7.2.2 Mechanical Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Post Construction 6.7.2.3 Mechanical An air and/or hydronic system balancing report is provided for HVAC systems serving zones>5,000 ft2 of conditioned area. HVAC 6.7.2.4 Mechanical HVAC control systems have been tested to El El El ensure proper operation,calibration and adjustment of controls. Post Construction 8.7.1 Interior Lighting Furnished as-built drawings for electric power 1:1 El El systems within 30 days of system acceptance. Post Construction 8.7.2 Interior Lighting Fumished O&M instructions for systems and El equipment to the building owner or designated representative. EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 15 of 21 Input Data Report Proiect Information Project Name: Pizza Hut Project Title: Pizza Hut Address: 6915-5953 GALL BLVD. State: FL Zip:-0 Owner: NPC Building Type: Dining:Family Building Classification: Renovation to existing building No.of Stories: 1 GrossArea(SF): 1,828 Bldg.Rotation: None Zones No Acronym Description Type Area Multi Total Area rsfl lsfl 1 Pizza Hut Pizza Hut CONDITIONED 1828.0 1 1828.0 Spaces No Acronym Description Type Depth Width Height Mult Total Total [ft] [ft] [ft] Area Vol[cf] [sfJ In Zone: Pizza Hut 1 Lobby Lobby Lobby(General)-Reception 1.00 323.00 10.00 1 323.0 3230.0 and Waiting 2 Rcstroom Restroom Toilet and Washroom 1.00 82.00 12.00 1 82.0 984.0 3 Kitchen Kitchen Food Service-Kitchen 1.00 1423.00 9.25 1 1423.0 13162.8 ❑ EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 16 of 21 Lighting No Type Category No.of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: Pizza Hut In Space: Lobby 1 LED General Lighting 13 12 156 Programmable timer 1 ❑ without Daylighting 2 LED General Lighting 3 10 29 Programmable timer 1 ❑ without Daylighting 3 LED , General Lighting ..3 8 24 Programmable timer 1 ❑ without Daylighting In Space: Restroom 1 LED General Lighting 1 45 45 Occupancy sensor without 1 ❑ Daylighting In Space: Kitchen 1 LED General Lighting 16 45 720 Programmable timer. 1 ❑ without Daylighting 2 LED General Lighting 3 44 131 Programmable timer 1 ❑ without Daylighting Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H(Effec) Multi Area Orient Cond- Heat Dens. R-Value [ftl [fti plier [sfi ation uctance Capacity Vb/cf[ [h.sfXBtu] 1Btu/h.sEF1 [Btu/sf.F] In Zone: Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area [Btu/hr sfF] Ift] [ft] plier Isf] In Zone: In Wall: El EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASH RAE 90.1-2013-Prescriptive Compliance Option ' 7/6/2018 Page 17 of 21 Doors No Description Type Shade? Width H(Effec) Multi Area Cond. Dens. Ht Cap. R [ft] IN plier [sf] [Btu/h.sf.F] [lb/cf] [Btu/sf. [h.sf.F/ F] Btu] In Zone: In Wall: Roofs No Description Type Width H(Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/h.Sf.F] [Btu/sf.F] [lb/ct] [h.sf.FBtu In Zone: Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multi- Area Total Area [Btu/hr sf F] [ft] [ft] plier [SfJ [Sf] In Zone: In Roof: Floors No Description Type Width H(Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/h.sf.F [Btu/sf.F] pb/cf] [h.sf.FBtu In Zone: EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 18 of 21 Systems RTU-1 RTU-1 Constant Volume Air Cooled No.Of Units Single Package System< 1 r Component Category Capacity Efficiency IPLV 1 Cooling System 43.20 14.50 8.00 ❑ 2 Heating System 80.00 81.00 ❑ 3 Air Handling System-Supply 1600.00 0.70 ❑ R_TU-2 RTU-2 Constant Volume Air Cooled No.Of Units Single Package System< OUR 1 r Component Category Capacity Efficiency IPLV 1 Cooling System 50.80 14.00 8.00 ❑ 2 Heating System 75.00 81.00 ❑ 3 Air Handling System-Supply 1600.00 0.70 ❑ RTU-3 RTU-3 Constant Volume Air Cooled No.Of Units Single Package System< 1 r Component Category Capacity Efficiency IPLV 1 Cooling System 61.10 14.00 8.00 ❑ 2 Heating System 75.00 81.00 ❑ 3 Air Handling System-Supply 1950.00 0.58 ❑ Plant Equipment Category Size. InstNoEff. IPLV Water Heaters W-Heater Description Capacity Cap.Unit UP Rt. Efficiency Loss 1 Gas Storage water heater 60 [Gal] 125000 [Btu/h] 96.0000 [Ef/Et] [Btu/h] ❑ EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 19 of 21 Ext-Lighting Description Category No.of Watts per Area/Len/No Control Wattage Lumin- Lumin- [sf/ft/No] 1'pe [W] aires aire Piping No Type Operating Insulation Nomonal pipe Insulation Is Temp Conductivity Diameter Thickness Runout? [F] (Btu-in/h.sf.F] [in] [m] Fenestration Used Name Glass Type No.of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] Materials Used Mat No Acronym Description Only RValue Thick Cond- Density Sp.Heat R-Value [h.sf.F/Btu] (ft] uctivity Rb/ci] [BtuAb.F] Used [Btu/h&Y El EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,.Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page-20 of 21 Constructs Used . Simple Massless Conductance Heat Cap Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] @.sf.FBtu] Layer Material Material . Thickness Framing No. [ft] Factor EJ EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option 7/6/2018 Page 21 of 21 Jacqueline Boges From: Pamela M.Walton <pwalton@pascocountyfl.net> Sent: Friday, February 1, 2019 8:42 AM To: Jacqueline Boges Subject: RE: Pizza Hut - 5897 Gall -Zephyrhills Address PS You passed your morning test! From: Jacqueline Boges [mailto:jboges@ci.zephyrhills.fl.us] Sent: Friday, February 01, 2019 8:35 AM To: Pamela M. Walton Subject: RE: Pizza Hut- 5897 Gall - Zephyrhills Address i Pam this says 5883 gall blvd is this correct or the 5897 go within this parcel? From: Pamela M.Walton<pwalton@pascocountyfl.net> Sent: Friday, February 1,2019 8:18 AM To:Jacqueline Boges<jboges@ci.zephyrhills.fl.us> Subject: RE: Pizza Hut-5897 Gall-Zephyrhills Address i 1 i I Jacqueline Boges From: Martha Simons Sent: Wednesday, February 6, 2019 12:37 PM To: Jacqueline Boges Cc: CJ Funnell Subject: RE: pizza but Jackie,I have contacted Fathom and they will correct the address to 5897 Gall Blvd and notify GIS to have it mapped to the correct location. I am copying CJ so he is aware of the address change. Thank you. From:Jacqueline Boges<jboges@ci.zephyrhills.fl.us> Sent:Wednesday, February 6,2019 11:46 AM To: Martha Simons<MSimons@ci.zephyrhills.fl.us> Subject: RE: pizza but No show act#0000986980-002402564 no meter#is ever given to me will this help? From: Martha Simons<MSimons@ci.zephvrhills.fl.us> Sent:Tuesday, February 5,2019 3:15 PM To:Jacqueline Boges<iboges@ci.zephvrhills.fl.us> Subject: RE: pizza but I can contact Fathom and get it corrected if you would like.Do you have a meter V Is it 1546633630? From:Jacqueline Boges<iboges@ci.zephyrhills.fl.us> Sent:Tuesday, February 5,2019 3:11 PM To: Martha Simons<MSimons@ci.zephvrhills.fl.us> Subject: RE: pizza but How can I change that? From: Martha Simons<MSimons@ci.zephvrhills.fl.us> Sent:Tuesday, February 5,2019 3:10 PM To:Jacqueline Boges<iboges@ci.zephyrhills.fl.us> Subject: RE: pizza but You are correct.The address in the system is 5915 Gall Blvd. From:Jacqueline Boges<iboges@ci.zephyrhills.fl.us> Sent:Tuesday, February 5,2019 2:54 PM To: Martha Simons<MSimons@ci.zephvrhills.fl.us> Subject: RE: pizza but Address I believe they may have in the system is 5915 gall blvd but should be 5897 gall blvd pasco county addressing gave me the correct address but when I ordered the meter I gave 5915 gall to fathom for the new service could you verify for me? i I �'j i Idenfirfy - X' �. m } Identify from: tV51ble Cn K ip R.-Sections ;17a I ..... Q 0 r [-J.-Parcels Current �- 10 26 210020 00000. 0090 -D ['I••2018-SID e RGB tD s P- tD N � Q I (D *^ [EEL] (n . I Location: > 595,499.22-2 1,421,111.133 Feet Field Value tD �''• _ LPARCEL : 2126100020000000090 VPARCEL 10 26 21 0020 00000 0090 (D ACRES 0.34 [ NAME1 ZEPHYR SUNRISE LLC �•- NAME2 N • NAME3 7162 READING RD STE 730 NAME4 NAMES CINCINNATIOH 45237-3845 PHYSADDR 5883 GALL BOULEVARD LEGAL1 PINE GROVE ADDITION PB 2 PG 15 . ; LEGAL2 COM AT SE CDR LOT 9 TH NOODEG LEGAL3 07'25"W 31.60 FT FOR POB TH LEGAL4 WEST 104.12 FT TH NORTH 108.06 LEGALS FT TH N45DEG12'52"E 91.27 FT (D `' LEGAL6 TH S44DEG47'08"E 5.44 FT TH , r" LEGAL7 SOODEG07 25 E 133.01 FT TO POB LEGAL8 TOGETHER WITH AN ESAEMENT PER Ll LEGAL9 OR 412 PG 731 LEGALIO OR 9679 PG 2653 R• SALEYRI 18 - I SALEMN1 02 P� SALEBKI 9679 SALEPGI 2653 SALEM WD rAI rr-rl 2 From: Jacqueline Boges [mailto:jboges(abci.zephyrhills.fl.us] Sent: Friday, February 01, 2019 8:14 AM To: Pamela M. Walton Subject: RE: Pizza Hut- 5897 Gall - Zephyrhills Address Hey pam one more thing what is the parcel id # From: Pamela M.Walton<pwalton@pascocountvfl.net> Sent:Thursday,January 31, 2019 1:25 PM To: Blake Crossno<blake.crossno@npcinternational.com>;Jacqueline Boges<Iboges@ci.zephvrhills.fl.us> Subject: RE: Pizza Hut-5897 Gall-Zephyrhills Address Jackie, The correct address for the new Pizza Hut in Zephyrhills is 5897 Gall Blvd. The one that you have (5915 Gall Blvd.) is being used by the existing business next door. From: Blake Crossno [ma i Ito:blake.crossno(cbnpcinternational.com] Sent:Thursday, January 31, 2019 11:08 AM To: Pamela M. Walton Subject: Pizza Hut- 5897 Gall -Zephyrhills Address Hello Pam, How long do you think it will take for our verified address to be registered with the city?We have city water guys lined up to install our water meter today but cannot do so until the address is recognized. Thanks, Blake Crossno I Real Estate Analyst 4200 W 115'h Street I Leawood, KS 166211 Direct:913-327-3124 1 Mobile:913-403-6742 � I ktll+=�i�R� •.v.v�nn-:r:',rnuLnr.srccm NOTICE:This electronic mail message and any attached files are confidential.The Information is exclusively for the use of the individual or entity intended as the recipient.If you are not the intended recipient,any use,copying,printing,reviewing,retention,disclosure,distribution or forwarding of the message or any attached file Is not authorized and is strictly prohibited.If you have received this electronic mail message In error,please advise the sender by reply electronic mail Immediately and permanently delete the original transmission,any attachments and any copies of this message from your computer system. { f "Bringing Opportunities Home" 3 CITY OF / / / BUILDING ZEPHYRHILLS D EPARTMENT OF ADDITION OR CORRECTION D • NOT REMOViE ADDRESS DATE PERMIT f `' i566x,L ( 6 n . � 5 THIS JOB HAS NOT BEEN COMPLETED, The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with Flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR CITY OF " NOTICE " / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS � DATE PERMIT� 5 THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the;job will be accepted. Uv t tt�f 6A---Yc3 14 p u4t - t AJ It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR�_ dj Jacqueline Boges From; ` City of Zephyrhills Support <so Usf.zendesk.corn> Sent: ` Monday, December 17' 2O1O3l9PK4 .� To: ]acqmelineBooem ' Subject: [Request received] S915 Gall blvdbo#2OS81 ##- Please type your reply above this line -## Hello Jacqueline Buges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, , FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: ------'' ..........- .............................---............ ------------�................ - --.------- ................................................. --'---.............-................................ ------- - Jacqueline Boges ` — Dec 17. 1 :08 PM MST service for 5915 gall blvd bo#30581 This email iya service from City ofZephyrhU|s Support . 1 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20821 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20821 Address: 5897 GALL BLVD Permit Type: SIGN ZEPHYRHILLS, FL. Class of Work: WALL SIGN Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 10-26-21-0020-00000-0090 Improv. Cost: 2,295.00 OWNER INFORMATION Date Issued: 2/18/2019 Name: ZEPHYR II LLC Total Fees: 150.00 Address: 7162 READING RD STE 730 Amount,Paid: 150.00 CINCINNATI OH 45237-3845 Date Paid: 2/18/2019 Phone: Work Desc: INSTALL WALL SIGN FRONTAGE W/ ELECTRIC PIZZA HUT CONTRACTORS APPLICATION FEES COX ELECTRIC SIGN 82.50 COX ELECTRIC ELECTRICAL FEE 67.50 Ins ections Required F OTER ELECTRICAL ROUGH FINAL REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with, City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORVIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780.0020 City of Zephyrhills Permit Application Y 7Fax-81021 Building Department dd Date Received L, phone Contact for P mIttl. 1 o 00 T Owner s Name �7 (} +�? Owner Phone Number Owner's Address (� (� J I / l o Owner Phone Number f Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address y�JOB ADDRESS (` Or k/ 6,&1 n LOT# SUBDIVISION PARCEL ID# T 6 s (/ ZI— 00 ze — 0 0 i00O-a0 j 0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT = SI_ GN Q DEMOLISH INSTALL REPAIR PROPOSED USE = SFR = COMM OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME STEEL = DESCRIPTION OF WORK S I d r u�t 0 I ! a Qn3 BUILDING SIZE —� SQ FOOTAGE G��3 HEIGHT 1 PI . 1 1 1 1 1 11 1 1 1 11. IT7T1"ITI1T7" --- NBUILDING $ J C VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ So AMP SERVICE = PROGRESS ENERGY = W.R.E�C. , =PLUMBING $ ��� 1 =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 1� 1 � U =GAS = ' ROOFING Q SPECIALTY = OTHER l FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY •60• .I'I e. .rI L SIGNATURE �C-- REGISTERED c Y/ N FEE CURREA I Y/N Address V v� 5ti Q.sy �/I License#I ce,000 0 ELECTRICIAN COMPANY Fi eG f/,!/ SIGNATURE �1.. REGISTERED I Y/ N FEE CURREN I Y/N Address g S fz d / License# 1 &-D(6710.� PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURRE< I Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREA Y/N Address LlcensQ# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURRET I Y/N Address License# IIIIIIAIIIIiII111J111111 lilt III II III IIIIaIIIIIIIII1I11111111111111.1-1 RESIDENTIAL Attach(2)Plot,Plans;(2)sets of Building,Plans;(1)set of,Energy Fonns;R-O-W Permit for new construction, Minimum ten(10)wbrking-days after submittal date. Required onsite,Construction Plans.Slormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionsllarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Slonnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) •' Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhilis Permit Application Fax-e1 021 Building Department — i" Date Received) 3 '' +�f o' 00 0 Phone Contact for P milting T` Ti i'1 Owner's Name Lb c r 7 Owner Phone Number Owner's Address V Z )n S 1} , 7/o' Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address �q JOB ADDRESS '+I ocv 6vo I Iv it LOT# SUBDIVISION PARCEL ID# I() ZI' 0 0 Z7 0 0000 00 jC (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR = COMM t&j OTHER TYPE OF CONSTRUCTION = BLOC(Ka = FRAME = STEEL = DESCRIPTION OF WORK AS `d— 1 vn C '��w W I S pr�'1� BUILDING SIZE SQ FOOTAGE Lg , HEIGHT r l r l l r rl r r . I l r r�Trr.r BUILDING $ '7 �. C VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ �(�/ J AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER / COMPANY SIGNATURE no REGISTERED `/ Y/ N FEE CURREN Y/N Address VvS dSd✓ Q,fl f/I - License# 66 000 O ELECTRICIAN COMPANY �ileG lllr SIGNATURE �ry p�ti/, { REGISTERED Y/ N FEE CURREN Y/N Address 0 J eS-L fT S 1 Lt n l� /I License# 1 &12OD,7, �7 PLUMBER COMPANY SIGNATURE F REGISTERED Y/ N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Address License,# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA Y/N Address License# IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. - - - - - - - - - - - - - - - - - - - - Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required., (A/C upgrades over$7500) '• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ' • NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. if the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,1 certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",1 certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in Connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise In good faith to Inform the owner of the permitting conditions set forth In this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENTj� CONTRACTOR_/` Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who is/are personally known to me or hasihave produced Who is/are personally known to me or hasfhave produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Copy on Installer's Letterhead Date: 01/07/2019 To Whom It May Concern: License Holder: LAWRENCE T COX State License: EC0002106 Firm Address: 6845 MAPLE LANE TAMPA FL 3310 Telephone Number: 813-621-1161 1 hereby authorize the following individuals to act as my agent in all areas of permitting and licensing procedure with the municipality to which this is presented. This authorization is for sign permits at various locations and to register the contractor X This authorization is for the following location: 5897 GALL BLVD,ZEPHYRHILLS FLORIDA Stephanie Arce Cindy Gould Ed Krauss Theresa Krauss Charlie Buff Amanda Barnum Date 01/07/2019 Signed.- n I /A Contractor CONTRACTORS SIGNATURE NOTARIZED: State of Florida County of Subscribed before me on this -11�1 day of �cJ1n . 249+&by E LCtiwrwcp ( C6x who is erso Ily known to me. Notary Signatur t �.►� Notary Public State of Florida Kathy Leon a My Commission GG 116030 Commission Number 1AV %OF a Expires 06/20/20121 My Commission Expires: INSTR# Z0j$ Zbbb t BK %bo PG � 02/18/2019 09:36am Page i of 1 Rapt: 2029264 Rec: 10,00 DS: 0.00 IT: 0.00 Paula S. O'Neil , Ph.D. � i Pasco County Clerk & Comptroller Permitf7o: - wParai;I6* If 0 C I NOT{G CCINI T31+ ARENCWEN - iHE UhJDER51GNE6'ttetebY gives no8ce tha;imptovemeniwUi' made.ta certain reat'propeity;and:in accordance;with Chaplet 713,Fiorida'Statutes, ttve totlowing mfotmakon rs provded iridhis Notice of Commanceman i i- 1. ...DescripUoo of P,rope`rty Mid tM lion No.. yy�� ! Z' 1 S 7 �.cv. Ctf7L -'ryi8 gam' :P PJ. Stiersl Address:; y� i.p 2, Gerterat`Oescripiion of linprovement 3. Owner Informd"O f Lessee information if the Lessee contracted for the improvement 6. A dross;`: Gi�y, State Interest=in`Pr6pnrty: ®ta)4�1_49/0. Nagle of Fee Siinple Titleholder. (if different from Owner listed above) ' Address City State 4. Coniracior ;.. Address ( City. State Cdhhactoes Telephone No.: t 001 11 5; Surety C_ Name. -Address''. City State Amount'of Bond:.5. Telephone;No - 6. Lender,:... - Address:; City State Lerider's Telephmie No.: 7. Persons'Ahin the Stata of Florida,dasignated.by the=oWnei'upon whorn notices or other documents maybe served.as provided by, Section 713,13(i)(a}(7}:Fforfda statutes;. : - . Name AdBrass:. City State Telephone Number of Designated Person: 81 in addition tohimself,tho' 'own'or of ,1b receive a copy of the Lfeno6 Node, provided Sedi6n T 13.13(1.}(oI;Florida Statutes.- Telephone Numb;srof PetSortor txittty Des"Ic4aited Z y 9. E)pkation date of Notice of Cornmencernent(the.exoiration'date may not be before the completion of mnstruction and anal P"Plit to the contnictor,butvAl b i brin;y-ear•from.the date of recording unless a diffeianf data is speGfled): WARNING TO 6WNER:`AN1f PAYMENTS MADE BY.7HE',OW,NER'AFTER THE-E,XPIRATION'OF THE NOTICE OF COMMENCEMENT,- I ARE CONSIDERED:IMPftOP.ER:.PAYMENTS::UNDER"CHAPTERM.'PARTA;"SECTION713A3,'FLORIDA"STATtffES,;AND CAN RESULT•IN'YOUR'PAYING.TWICE FOR'IMPROVEMENTS;:TO.YOUR PROPERTY.,,A-NOTICE OFF COMMENCEtrtEtJT,MUST, BE RECORDED,AND POSTED,ON THE'JOB SITE BEFORE THEFIRST,INSPECTION::.iF YOU INTEND TO;OBTAIN FlNl1NCtNG;:CONSULT -WITH YOUR LENDER OR'AN ATTORNEY BEFORE COMMENCING,WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty cif,perjuiy,l declare that I have read the foreg6ing''AWC6 of conimericement and that the fads stated fherefn are true to the.best of my knovifedge and belfer. STATE.OF 14 G►f,&:t o . COUNTYOF P4fRSC0 J {'j♦7yrv►lc►C"tf 1�,� ' Signature of Owner or lessee;or Owner's or Lessoe's Authorized OtticerlDiractorlPertnerlManager.' - : -Slgnatory's:TittalOfflco _ �:. , _ • ; is - The fore9.1nstrumentvyas acicriov+iedged Bofors me,thls I� .day'of 20 d.t?y, r.. - ' go'In , s .... ... e :- (type of aui'ty�:g.;o cot:irusi��amey in fact)for., insirumenfwas"'executed). Personally Known.0 9R,Produced tdenGflca36n Notary Signature Type of Identification Pro%duced V r►' r/[� Name(Print} Pak z 'In tlllA ft dim. ' 03 Malt 2023 - wpdata(basJnoUcecommaricement_pc05304f3 �• , Owner consent for sign Installation and permits I %A prt R. 0. r , being the owner, manager of the business/property (individual's Name) known as Pizza Hut and located at 5900 Block Gall Blvd do (name of business) (street address) hereby certify that I am allowing Everbrite, LLC. (and/or Cox Electric) to obtain permits and install signage at the below mentioned address. Everbrite, LLC further agrees that all work will be done in compliance with all applicable laws, codes and ordinance, and any stipulations or-restrictions listed-on - the permits. Site address: Pizza Hut 5900 Block Gall Blvd Zephyrhills, FL 33542 Signature —� Name AA/}(2t,,. p A� 11,4- yyl� 2 Date J o gkon on. i City"of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 0,06 6 "- Date Received: I 2-3/� t-0 Site: Permit Type: ;,S AARC Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: CO) ©ivq�-,fs This comment sheet shall be kept with the permit and/or plans. &JIL /-7 Examiner Date Contractor and/or Homeowner (Required when comments are present) Jacqueline Boges From: Gail Hamilton Sent: Thursday, February 14, 2019 11:17 AM To: Jacqueline Boges Cc: Cindy Gould Subject: FW: PF56258-111 PH4678-1 11 ZEPHYRHILLS, FL Permit/Permit Procurement Attachments: Pizza Hut Zephyrhills Sign 1.pdf Good Morning Jackie Attached is the only approved sign for the Pizza Hut located at Zephyr Plaza, logo and sign at primary frontage only. No signage located on secondary side location. As discussed, signs are field inspected. Thanks! Gail From:Cindy Gould<wcfpermits.cindy@gmail.com> Sent:Thursday, February 14, 2019 10:59 AM To:Gail Hamilton<G Ham ilton@ci.zephyrhills.fl.us> Subject: Re: PF56258-11 1 PH4678-1 11 ZEPHYRHILLS, FL Permit/Permit Procurement We will only being Sign 1, attached, thanks. On Thu, Feb 14, 2019 at 10:56 AM Gail Hamilton<GHamilton@a,ci.zephyrhills.fl.us>wrote: Cindy jPlease send the plans for the sign, without the logo included. i Thanks! Gail i From:Cindy Gould<wcfpermits.cindy@gmail.com> Sent:Thursday, February 14, 2019 9:53 AM To:Gail Hamilton<GHamilton@ci.zephvrhills.fl.us> - Subject: Re: PF56258-1 1 1 PH4678-1 11 ZEPHYRHILLS, FL Permit/Permit Procurement Hi Gail, I We are going to drop the logo sign from the package at this time. Can you please just approve the 1 sign for now so we can get this permitted, thanks. i On Tue, Feb 12, 2019 at 12:30 PM Gail Hamilton<GHamilton@a,ci.zephyrhills.fl.us>wrote: Okay, as soon as I get the new drawing and verify signage, I will sign off on plans. I � Will get this moving again! I am taking web class and cannot use phone but will be checking emails so if you have question,just send email. f Thanks again! Gail From:Cindy Gould<wcfpermits.cindv@gmail.com> Sent:Tuesday, February 12, 2019 12:24 PM To:Gail Hamilton<GHamilton@ci.zephvrhills.fl.us> Subject: Re: PF56258-1 1 1 PH4678-1 11 ZEPHYRHILLS, FL Permit/Permit Procurement Hi Gail, I know this has been weeks ago but I am just getting them now from the building department. ' I The frontage is 29'-10" I am waiting on the new drawing and engineering but the logo will be reduced to 3'or less I i I On Tue, Feb 12, 2019 at 12:20 PM Gail Hamilton<GHamilton@c;i.zephyrhills.fl.us>wrote: i Good Morning Cindy, i On my goodness....comments were sent back several weeks ago. SO let's get this completed ASAP! j Just have couple of questions....can't see on plan....what is the footage of the primary frontage? jPlease confirm you have reduce logo in size to 3" feet or less. I Thanks so much! Gail 2 From:Cindy Gould<wcfpermits.cindy@gmail.com> Sent: Monday, February 11, 2019 2:58 PM To: Gail Hamilton<GHamilton@ci.zephvrhills.fl.us> Subject: Fwd: PF56258-11 1 PH4678-1 11 ZEPHYRHILLS, FL I I Permit/Permit Procurement Hi Gail, i I am just receiving your comments in regards to signage for the Pizza Hut in Zephyr Plaza. The signs we ' submitted for are on a raceway, they are not cabinet or box signs. I understand that the logo sign is too high. Please advise. I Thanks so much!! I I Cindy Gould Director of Permit Procurement West Central Florida Permits 12319 Forest Highlands Drive Dade City, FL 33525 I Office: 813-907-8000 Fax* 813-907-8088 www.wcfpermits.com ill 3 ' A it2 t [�1 2 14 O - \ t \ 4S \� t 4. V, 4 s t - - A Q `'` 2 v 15 �I 2 2 11'-6 1/8" Backer 7-61/2' — — W-10" i �- --—7-4 1/8"---� 8'-6 7/8' 77L/8' 51 2'-4 7/ 2'-01/4' AO 2,4 1'-9' White- LED 3M 3630-33 RED VINYL L BLACK RETURNS&BACK PLATE BLACK RETURNS&BACK PLATE t j'Customer.:Pizza Out i::Description:'; :. '1,Ca'storn&Appr6vab Graphics and,colors on fild will be used-unless otherwise spedried'by,I j,oustomer;Please revi8w.,drawing;garefully.By si nir►g below,ypu agree to graphics as• „ 1?rgject Na:.,384456 . V'.Scale: LHB21`Channel',Letter:SeC . shown above•and to location of si ri as,shown. lease retum.s tl ca ba 9 ne ckto:Everbnte ' 19 py Brawn "Date:6141 S Y- , GUSTO W - MERSGNATUf4E': .DATE .. ,.. Location&Site.Na:590q-Block Gall•Blvd"s.'� ReVised::�� - -� Zepli ills;FL'''`Site:PH4678: ,I - ,. .. - DATE, LANALORD.StGNfCfUq,. :...1''. . � Gail Hamilton From: Gail Hamilton Sent: Friday,January 04,2019 2:51 PK To: Bill Burgess;Jacqueline Boges Subject: Zephyr Plaza - Pizza Hut Good Afternoon In reviewing the signage plans for the new Pizza Hut: Sign 1: • Internally illuminated cabinet signs or box signs are not permitted. Channel Letters,graphics or artistic elements incorporated as part of the signage composition maybe internally or back-lit. • Sign height and length are within the max range. Sign 2: • Internally illuminated cabinet signs or box signs are not allowed.Graphics or artistic elements incorporated as part of the signage may be internally or back-lit. • Sign exceeds max height limit at 4'3 7/16,the max height is 3'. • Sign length is well within max range. Thank you l Gail Gail K Hamilton Director Community Redevelopment Agency City of Zephyrhills 5335 8th Street Zephyrhills, Florida 33542 Direct 813-780-0202 ghamiltonCcbci.zephyrhills.fl.us • mil i Encon Services, Inc. Sign Design Calculations . Job Description PREPARED BY: Encon Services, Inc. PIZZA HUT(NPC) P.O. Box 3613 5897 GALL BOULEVARD Apollo Beach, FL 33572. ZEPHYRHILLS, FL 33542 813-655-3373 21"Word Cloud F 813-655-9814 Design per Florida Building Code,6th Edition(2017)Section 16 Wind Load ASCE 7-10, Load Case: D+0.6W Aaron Biedenbach, P.E. Design Specifications FL PE#52949, FL EB 9394 Risk Category II OH PE 60756, OC#01893 Kzt 1 KY PE #20281, P#2463 Exposure Factor C IN PE#PE 19600332 Kd 0.85 FL CBC#060535,QB#22527 Kz V 0150 (mph) O�.98 Q ��ED�N • GCp-GCpi 1.4 Zone 5, H<60 Feet Wind Pressure 67.2 (psf) �' L I C E N S E �y #52949 Sign Information Height 2.00 ft Width 8.83 ft ,0� STATE OF Thickness 0.75 (ft) QR�QQ'` Distance grade to top 30 (ft) FS'S� NG Wind Shear Force 60.46 (lb) Weight of Sign 177 (lb) DATE SIGNED: Total Shear Force = 186.72 (lb) 12/20/2018 Total Tension Force = 712.04 (lb) Required Provided Fastener size(Nominal) 3/8 3/8 Minimum number of fasteners 6 6 Shear Force per fastener(lb) 31.1 280 Tension Force per fastener(lb) 118.7 352 Combination Tension and 0.45 <1 O.K. Sheer ratio THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. WALL STRUCTURE ANCHOR TYPE WOOD BLOCKING LAG BOLT(3-EMBEDMENT)THROUGH BLOCKING EIFS OVER 51W PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-112°EMBEDMENT) SOLID CONCRETE WEDGE ANCHOR(2-1/2°EMBEDMENT) CMU,SOLID CONCRETE,BRICK IHILTI HIT ROD WIHY-20 ADHESIVE(31/2°EMBEDMENT) ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS 12/20/2018 Pizza Hut Zephyrhills 21 in Letters and Logo SCLH82IH_IN c /51Y 2- T.O PLATE 4 - I , I ' 13'-4' 12-0' __ I TRUSS BEAR f TRUSS BEARING 2 • 15 17 ' 8 0 2 2 2 15 3 15 16 � • 4'-6 15/16" 4'-3 3/16" Backer 5 5 —{ 4'-3 7/16" 3M 3630-33 RED VINYL BLACK RETURNS&BACK PLATE ' 4' white LED C)ISCLAIMER.-Renderings are for graphic purposes only and not intended for actual construction dimensions,For windload recludrements.ac'tual dimensions and mountingdetall,please refer to engineering specificati. prohibited.These drawings and designs are the exclusive property of Everbrite LLC Use of,or duplication in any manner without express written permission of Everbrite LLC is Customer: Pizza Hut Description: Customer Approval:Graphics and colors on file will be used unless otherwise specified by Project No: 384456 scale: CSB-48 Channel Logo Sign customer.Please review drawing carefully.By signing below,you agree to graphics as shown above,and to location of sign as shown.Please return signed copy back to Everbrite. Date:6/418 Drawn By: RB Location&Site No:5900 Block Gall Blvd. Revised: CUSTOMER SIGNATURE DATE Zephyrhilis, FL Site:PH4678 RevlSed: LANDLORD SIGNATURE DATE f • ' Encon Services, Inc. Sign Design Calculations Job Description PREPARED BY: Encon Services, Inc. PIZZA HUT(NPC) P.O. Box 3613 5897 GALL BOULEVARD Apollo Beach, FL 33572 ZEPHYRHILLS, FL 33542 813-655-3373 48"Logo F 813-655-9814 Design per Florida Building Code, 6th Edition(2017)Section 16 Wind Load ASCE 7-10, Load Case: D+0.6W Aaron Biedenbach, P.E. Design Specifications FL PE#52949, FL EB 9394 Risk Category II OH PE 60756, OC#01893 Kzt 1 KY PE #20281, P#2463 Exposure Factor C IN PE#PE 19600332 Kd 0.85 FL CBC#060536,QB#22527 Kz .98 V 0150 (mph) O�Q• �,�®�y� GCp-GCpi 1.4 Zone 5, H<60 Feet Wind Pressure 67.2 (psf) LICENSE 9�y #52949 Sign Information Height 4.00 (ft) Width 4.25 ft ,off STATE OF Thickness 0.75 (ft) �,C FCQR��P` Distance grade to top 30 (ft) Wind Shear Force 120.91 (lb) Weight of Sign 170 (lb) DATE SIGNED: Total Shear Force = 208.61 (lb) 12/20/2018 Total Tension Force = 685.17 (lb) Required Provided Fastener size(Nominal) 3/8 3/8 Minimum number of fasteners 6 6 Shear Force per fastener(lb) 34.8 280 Tension Force per fastener(lb) 114.2 352 Combination Tension and 0.45 <1 O.K. Sheer ratio THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. WALL STRUCTURE ANCHOR TYPE WOOD BLOCKING LAG BOLT(3"EMBEDMENT)THROUGH BLOCKING EIFS OVER 5/8"PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-112"EMBEDMENT) SOLID CONCRETE WEDGE ANCHOR(2-1/2°EMBEDMENT) CMU,SOLID CONCRETE,BRICK HILTI HIT ROD WIHY-20 ADHESIVE(3112-EMBEDMENT) ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS 12/20/2018 Pizza Hut Zephyrhills 48IN Logo C5848Channell-ogo_IN c INSTR#2619026867 OR BK 986O PG 95 Page.1 of 1 02/18/2019 09:36 AM Rcpt:2029264 Rec:10.00 DS:.0.00 IT:0.00 PauCa S. O'Nei4 Ph.D., Pasco County Clerk&Comptroller Pb J,, ?tea I -Q.)Y _ aMsamid Q (� Tw o�t�it - �h5�tiiFl0it0r�PpEs�lc�Isb4�hYUMipep�(9,ordlniCaardngt�CIrPIK'113.Ftgf4l�St�1. 1 owl r„er ► (>,ro�a. Pb. Z !S clft- n S C L t3roifN`I)weeldYngv,ti�flHl a ohn.rrda�flM�onait�w•�16foee.eotiri�inw►ltiorr�lnp�w�i�n.t Ul MY . u�a�lh:�op.ro,:. 0 c.�n•l�arz 1 str. It�me�BYt�pA?li�dp�rt �m,anoArT-1410 »wl�lc M�➢aritdtlptdi! . : Tompbwr-Ho Aft= LredrkTa pk .-No,. �. 1ir�n�MQb th.t;dll► Edo l..gripordd dntlN o.ar patbpttyu a tilis►.dopt my be.i,wW U pv/dW by . •��tdgi`tit�t+j(RT(A:Fio�lldC,us: TNgbm.N+mb1�MO�wi�Iq�Y�On: A .fitadAbrctobtmwH,fiorrtdglairlr ct .. .•_s•:._r---•--' .•-•:-.� ,.�:.�_-�Mi�o�fi�Yat�r-dflirt�ris _ Ft�bb�tifs`�.. .._ �.-• — ihhplltstlubb.rotPinoo.�P@yftYl>�C�'eb'Oeeifc — a. A, cggYnnefefefiiHon *AdPeY WOW . ooriNgot�Mt?IMAeapti�iiripatS6bbYle/Teau6kO.U�111F'1�d�ltt�io�idX ��,,yy�� T 1• P � �� � I �IPTt1:E,61F- !CE � {� 't+0 Q6TAt 1611ii1- , 1tiTtfutEY . ..•.. . .. . . tlndr 14ttt,w�twF45�faigdl�ti0tolkotao�Ia+oaw+lriQlOttlri�dast�dfMMe�iahstp.►�tii�t STytTQR ol+fr�m CAIti1�IQP C1?�rr1E0 N'n1Y+1��TH'� . 9�e!r .ar4�a+M"aa (iiti.a -s�,.on4r tiiwlw . Tyw �n�ard ' k, N�e.�(l31n1j • . • • - s��� �°,'MY-OonuwbMo�i Ems 03 May I023 a DIIC a STATE OF FLORIDA,COUNTY OF PASCO ��, � ��► THIS IS TO CERTIFY THAT THE FOREGOING IS A . G TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS.OFFICE ht IT t ; Ij MY HANDD',OFFICIAL SEAL THIS DAY OF4 bi-,gal ry 2 O( 7. PAULA S.O 188 'NEIL;CLERF�&CO PTROLLER • BY DEPUTY CLERK CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20811 COMM EXHAUST HOOD/DUCT PERMIT PERMIT INFORMATION �LOCATION INFORMATION Permit Number: 20811 Address: 5897 GALL BLVD Permit Type: FIRE COMM EXH HOOD/DUCT ZEPHYRHILLS, FL. Class of Work: FIRE-HOOD SUPPRESSION SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 10-26-21-0020-00000-0090 Improv. Cost: 1,600.00 OWNER INFORMATION Date Issued: 2/15/2019 Name: ZEPHYR II LLC Total Fees: 130.00 Address: 7162 READING RD STE 730 Amount Paid: 130.00 CINCINNATI OH 45237-3845 Date Paid: 2/15/2019 Phone: Work Desc: INSTALLATION HOOD-PIZZA HUT CONTRACTORS APPLICATION FEES UNITED SHEET METAL&AIR CONDITIFIRE PERMIT FEES 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 30.00 FIRE LIGHT TEST-Final Ins ections Required J Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME ENT " 4flL"6� rw— twl�� I ONTRACTOR SIGNATURE PERMIT OFFIC60 PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 818-780-0020 City of Zephyrhills Permit Application Fax-818-780-0021 'r Building Department Date Received I I( q Phone Contact for Permitting — Owners Name Z Gph .y Owner Phone Number Owner's Address t4oz �pd;� IZ4's1'�• 1,30 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Addres JOB ADDRESS LOT# SUBDIVISION PARCEL to# ID Z lm'2 1'Va a 17 •SCMD OD tt (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR B ADD/ALT = SIGN 0 0 DEMOLISH INSTALL REPAIR PROPOSED USE = SFR F71 COMM = OTHER TYPE OF CONSTRUCTIONQ BLOCK = FRAME = STEEL = DESCRIPTION OF WORK rktn1S OL'OYN" rS �%t � BUILDING SIZE I I SO FOOTAGE[ HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ MECHANICAL $I VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREr I Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREt Y/N Address I License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA I Y/N Address License# 1 l MECHANICAL COMPANY 1 Shw SIGNATURE REGISTERED I Un N I FEE CURREN I Y/N Address Y4CAA4 License# C C I�i 3q3 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# 1111111111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. DtrectI tns: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A(C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW j NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance With any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. if the applicant is someone other than the"owner ,I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work Will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel, alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT FLORIDA JURAT(F.S.117.03) 14, OWNER OR AGENT CONTRACTOR_ Subscribed and swom to(or affirmed)before me this Subscribed and swo to(or affirmed)bblore me this by .2 11 r 101 by O i& q L-c=cal a la. Who is/are personally known to me or hasihave produced Wh are erso known to me has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. HL OSBERG Name of Notary typed,printed or stamped Name of Notary typed,printed or stag fi1i Notary Public-State of Florida GOMMIsslon#FF 913582 My COMM.Expires Sep 25,2019 Bedded through National Notary Assn. 1'LOIiIOA\ „- City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: ant I B� v tfWCI ( e Permit Type: Approved w/no comments:2//Approved w/the below comments: ❑ Denied w/the below comments: ❑ �,p��:G vLr04 This comment sheet shall be kept with the permit and/or plans. Gene Brown—Fire Safety Officer Date Contractor and/or Homeowner (Required when comments are present) I ZEPHYRHILLS FIRE DEPARTMENT 38410 6th Ave Zephyrhills, FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy No.: Plan No.: Contractor: 0PJ1 Business Name:Name: ra2/4 Billing Address: Business Address: Business Phone No.: Billing Phone No.: Business Fax No.. Billing Fax.No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual- Education,healthcare,De tention&Correctional Public Assembly,Business, schools, Storage,Mercantile and Churches Site Plan N/C Industrial. no charge Sprinkler $50 Multi-Family/commercial .03 sf up to 800 sq ft $ 24.00 Standpipes $50 (Minimum Charge$24.00 801 -1,500 sq ft $ 34.52 Fire Pump $50 Plan Revisions DBL 1,501-2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 0-25 Heads $50 5,501-7,500 sq ft $ .187.52 Natural Gas $50 26 plus-Heads $100 7,501-10,000 sq ft $ 262.52 Fuel Tanks- pertank $50 STANDPIPE SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 Per Riser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recrea' ' $25 Per Pump $100 30,001-40,000 sq ft $ 1.050.02 C ntr61 ed Bum(15da: $100 FIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,500.02 Hood/Duct $50 1� 0-25 Devices $50 60,001-80,000 sq ft $ 2,100.02 Place of Assembly $50 Ann 80,001-($2,100.02)per 26 plus Devices $100 ea add 1,OOOsq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS Business closed until Flammable Application $50 Annual et $50 'otations corrected) Waste Tire Storage $50 Annual Dry SPRINKLER SYSTEMS ( Generator<KW $100 $50 Hydro Undergrounds $45, Generator>30 KW $100 Other $50 Hydrostatic Test $65 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Acceptance Test $45 persystem Fumigation Tenting $50 Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50 Annual LP installation per tank $50 FIRE ALARM SYSTEM Fuel Tank Installation $50 8 System Acceptance $50 (Per Tank) $50 Recall Acceptance $50 Natural Gas Installation $50 OTHER (Per System) Fire Wall/Smoke wan $15 perwall ❑ Spray Booth $50 LP Gas $25 per tank Natural Gas $25 per system Tent 10'x10'or greater $15 per tent Fire Pump $45 Fire Su $30 System Acce JaaGe xtraust Hood/Duct $30 e-ins ection DBL (other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS TOTAL ® INSPECTION TOTAL 7 0 PERMIT TOTAL GRAND TOTAL Comments: Date: Inspector: see back nlh FALSE ALARM FEE 1st Alarm N/C 2nd Alarm N/C 3rd Alarm -N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 Cont.Annual Inspection Fees 3-11 Units price per unit $ 5.36 12-25 Units price per unit $ 4.82 26-50 Units price per unit $ 4.29 51-100 Units price per unit $ 3.75 100 or more Units price per unit $ 2.68 Fire Safety re-inspection'types First Re-inspectloi N/C Second re-inspeci . $75 Third re-inspectior $ 125.00 Inspection scheduled but cancelled 24 hrs 50.00 TOTAL 111h tjMWEEM.P United Sheet Metal Air Conditioning Inc . 215 Contractors Way, Lakeland, FL 33801 Phone: 863-667-1322 Fax: 863-667-1140 License #CAC1819393 LETTER OF AUTHORIZATION I, Steven Lascola, Contractor/Qualifier of United Sheet Metal & A/C, on this qbvtkcL.� 0lc► , grant to, Sy; my authorization to sign MONTH-WAY-YEAR PRINT NAME OF AUTHORIZED PERSON for and obtain Permits and/or Development orders on my behalf. This authorization shall be valid until the Contractor sends a notarized letter requesting that this person be removed from this list. SIGNATURE OF CONTRACTOR STATE OF FLORIDA COUNTY OF POLK Subscribed and sworn to before me on this 1`6 day of�ebvv.ca 20 1°1 , who is personally known to me or presented Jas identification. NOTARY SIGNATURE My Commission Expires: n l n MONTH-DATE-YEAR �r rah Wowry Public State of Florida a s CommissEfin Marie jonfGG 012102 fi ues 71712020 io►io� PxP NOTARY SEAL CITY OF ZEPHYRHILLS ` 5335-8TH STREET (813)780-0020 20911 FIRE STANDPIPES PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20911 Address: 5897 GALL BLVD Permit Type: FIRE HOOD SUPPRESSION SYS ZEPHYRHILLS, FL. Class of Work: FIRE-HOOD SUPPRESSION SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 10-26-21-0020-00000-0090 Improv. Cost: 2,000.00 OWNER INFORMATION Date Issued: 3/04/2019 Name: ZEPHYR II LLC Total Fees: 160.00 Address: 7162 READING RD STE 730 Amount Paid: 160.00 CINCINNATI OH 45237-3845 Date Paid: 3/04/2019 Phone: Work Desc: INSTALLATION SUPPRESSION SYSTEM CONTRACTORS APPLICATION FEES FIRE F HER,INC. FIRE SUPPRESSION 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 30.00 CONTRACTOR CERTIFICATE 30.00 FIRE BALL ON TEST-Final Ins ections wired Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMM E%PM ENT " Ay in;w— zwj�� TRA TOR SIGNATURE PERMIT OFFIC60 PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 ZEPHYRHIL,fLS FIRE DEPARTMENT 38410 6th Ave Zephyrhills, FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy No.- Plan No.: Contractor: 7'y�{ mac. Business Name: 7 , Billing Address: &lo 616 Business Address: S- I l ,Lo 1_- —L ­5'yG 3 9 Business Phone No.: Billing Phone No.: g►3.9 y of Business Fax No.: Billing Fax Imo.: Contact: Contact: ? iti PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual- Education,healthcare,De tention&Correctional Public Assembly,Business, schools, Storage,Mercantile and Churches Site Plan N/C Industrial. no charge Sprinkler $50 Multi-Family/Commercial .03 sf up to 800 sq ft $ 24.00 Standpipes $50 (Minimum Charge$24.00 801 -1,500 sq ft $ 34.52 Fire Pump $50 Plan Revisions DBL 1,501 -2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 0-25 Heads $50 5,501-7,500 sq ft $ 187.52 Natural Gas $50 26 plus Heads $100 7,501-10,000 sq ft $ 262.52 Fuel Tanks- pertank $50 STANDPIPE SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 Per Riser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation' $25 ® Per Pump $100 30,001-40,000 sq ft $ 1,050.02 Pontrolled Bum(15da; $100 FIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,500.02 Hood/Duct $50 0-25 Devices $50 60,001-80,000 sq ft $ 2,100.02 Place of Assembly $50 Annual 80,001-($2,100.02)per 26 plus Devices $100 ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS (Business closed until Flammable Application $50 Annual Wet $50 violations corrected) Waste Tire Storage $50 Annual Dry $50 -SPRINKLER SYSTEMS Generator<KW $100 CO2 $50 Hydro Undergrounds $45 Generator>30 KW $100 Other $50 Hydrostatic Test $65 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Acceptance Test $45 persystem Fumigation Tenting $50 Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50 Annual 8 LP Installation per tank $50 FIRE ALARM SYSTEM Fuel Tank Installation $50 P System Acceptance $50 FALSE ALARM FEE 1st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 H6th Alarm $200 NON COMPLIANCE $150 Cont.Annual Inspection Fees 3-11 Units price per unit $ 5.36 12-25 Units price per unit $ 4.82 26-50 Units price per unit $ 4.29 51-100 Units price per unit $ 3.75 100 or more Units price per unit $ 2.68 Fire Safety re-inspection'types First Re-inspection N/C Second re-inspect $75 Third re-inspectior 125.00 -Inspection scheduled but cancelled 24 hrs $ 50.00 TOTAL Alh 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received v I Phone Contact for Permit ���1Y 2,7. 1 L L r Owner's Name Owner's Phone Number Owner's Address Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address^ � �/ � Lot# _. Sub Division Parcel# Bio-Hazard Waste Storage-ANNUAL Fumigation Tent FUI Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL inControlled Bum Hood Installation FjEmergency Generator<30 kw a LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale F7 Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL fUffyj emi [A7n ter Sprinkler ❑ ' ❑ ❑ Recreational Bum Fire Alarm ❑ ❑ ❑ Sparklers Hood Cleaning ❑ ❑ ❑ = Sprinkler System Installations Hood Suppression ❑ ❑ ❑ Standpipes,(Sprinkler Sys) Fire Alarm Installation Torch Roofing/Tar Kettle 0 Fire Pumps Waste Tire Storage ANNUAL Flammable Application-ANNUAL Valuation of Project Fuel Tanks 0 Other: Contractor I ZLpAa Company lit, P, y� Signature Registered /N Fee Iturrent Address I FOR" License# 10) 0 ELECTRICIAN Company Signature Registered I Y/N Fee Current Address License# PLUMBER Company Signature ' Registered Y/N Fee Current Address License# MECHANICAL Company Signature Registered Y/N I Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current Y/N Address License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be.licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,,as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws, regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions 1 , must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to;commencing construction. I understand that a separate permifmay be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued,shall be construed to be a license to proceed with the work and not as-autti6rity to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR J1J?11)`h Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(6r affi ed)before me this by by Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped t City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: J— 2— 54 9 Site: T Permit Type: cSl� r `s` Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ r This comment sheet shall be kept with the permit and/or plans. Gene Brown—Fire Safety Officer D"e ? Contractor and/or.Homeowner (Required when comments are present) _y Pizza Hut 5897 Gall Blvd. Zephyrhills, FL 33542 Fire Suppression System For Commercial Hood Fire Fighter Inc. P.O. Box 888 Land O'Lakes, FL 34639 813-996-6469 Gary F. Blair Lic. # 01350500011997 SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-1 7-1-09 REV.8 SYSTEM DESIGN GENERAL INFORMATION The ANSUL R-102 Restaurant Fire Suppression System may be 1.Nozzles must be located 2-8 in.(5-20 cm)into the center of the used on a number of different types of restaurant cooking appli- duct opening, discharging up.See Figure 1. ances and hood and duct configurations.The design information listed in this section deals with the limitations and parameters of this pre-engineered system.Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. 2—s Icm(5—20 ) 1 • Both systems must actuate simultaneously. T • Each system must be designed and installed per its appropri- FIGURE 1 ate manual. OW„3 • Adjacent appliances requiring protection must be protected 2.In installations where a UL listed damper assembly is with the same type of system, either R-102 or PIRANHA, employed, the duct nozzle can be Installed beyond the 8 in. unless the center-to-center spacing between the adjacent (20 cm) maximum,to a point just beyond the damper assem- ' R-102 and PIRANHA nozzles is no less than 36 in.(91.4 cm). bly that will not interfere with the damper.Exceeding the maxi- When appliances are protected with R-102 nozzles, the hood mum of 8 in. (20 cm) in this way will not void the UL listing of and connecting duct above those appliances cannot be pro- the system. tected with PIRANHA nozzles. 3.Previously listed 3 flow number and 5 flow number duct pro- Mixing systems in a common plenum is not allowed. tection detailed in earlier published manual, Part No.418087- One of the key elements for restaurant fire protection is a correct 06, can also still by utilized. system design.This section is divided into ten sub-sections:Noz- DUCT SIZES UP TO 50 IN.(127 cm) zle Placement Requirements,Tank Quantity Requirements,Actu- PERIMETER/16 IN.(41 cm) DIAMETER ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- One 1 W nozzle(Part No.419336)=one flow number tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements,and si Pressure Switch Requirements. Each of these sections must be 16 in.(41 cm) diameter maximum completed before attempting any installation. System design sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN.(254 cm) during installation. PERIMETER/32 IN.(81.3 cm) DIAMETER NOZZLE PLACEMENT REQUIREMENTS One 2W Nozzle(Part No.419337)=two flow numbers This section gives guidelines for nozzle type, positioning, and 100 in.(254 cm)perimeter maximum quantity for duct,plenum,and individual appliance protection.This . 32 in.(81.3 cm)diameter maximum section must be completed before determining tank quantity and piping requirements. The chart below shows the maximum protection available from each duct nozzle. Duct Protection—Single Nozzle Part 3.0 Gallon 1.5 Gallon All duct protection is UL listed without limitation of maximum duct Description No. System System length (unlimited length).This includes all varieties of ductworks 2W Nozzle 419337 Maximum Maximum both horizontal and vertical including ducts that run at angles to,. the horizontal and ducts with directional bends. 100 in.(254 cm) 100 in.(254 cm) Perimeter Perimeter The R-102 system uses different duct nozzles depending on the size of duct being protected. I Nozzle 419336 Maximum Maximum 50 in.(127 cm) 50 in.(127 cm) Perimeter Perimeter . . . . . . SECT|ON|V — SYSTEM DESIGN ' UL EX3470 ULCEX347 4-5 7-1-09 REV.s Plenum Protection The R,1 2 system uses the 1VV Nozzle (Part No.41833U) or the zle tip is stamped with I W and the 1 N nozzle tip is stamped with MAXIMUM 1 N, indicating they are one-f low nozzles and must be counted as one flow number each.When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. IN.(2.5 cm) MINIMUM VERT|CALPROTECTION—QENERAL ` 1VV NOZZLE — PART NO. 419336 — SINGLE AND"Y" BANK m) ^PROTECTION MAXIMUM One 1YY nozzle will protect 4 linear feet (12m) oi plenum.The maximum distance from the end d the hood to the first and last nozzle must beno more than cO(0.0n).After the first nozzle,any IN.(2.5,*) additional nozzles must be positioned o\a maximum o[4It(1.2m) Mm/wuw apart down the U length of the plenum.The plenum width must not exceed 4It(1.2m).(The VY nozzle can be used on single or V-honh filter armngomrn\nj See Figure O. FIGURE 000199 z~' MAXIMUM Option 2:The 1VY nozzle must be placed perpendicular, O'12in. (28'30on) from the face of the filter and angled to the center u/the filter.The nozzle tip must bo within 2in. MAXIMUM (5 the perpendicular center line of the hkec MAXIMUM e See Figure u MAXIMUM MINIMUM NOZZLE TIP MUST BE WITtIHIN THIS AREA FIGURE OW197 When protecting plenums with the 1VV nozzle,two options nfcov' omQo are available: FIGURE Option 1:The 1YV nozzle must b000 the center line nf the single or ''Y" bank filter and positioned within 1'20 in. HORIZONTAL PROTECTION—OPTION 1 ;2.5-51 onV above the top odQa of the 08»r. Ga» 1N NOZZLE—PART NO.41n83s—SINGLE BANK PROTECTION Figure 7' One 1N nozzle Will protect1D linear feet(].1m)of single filter bank plenum.The nozzle(s) must ho mounted in the plenum, 20u4in. (5 to 10om) from the face of the'8her, centered between the filter height dimension, and aimed down the length.The nozzle must ba positioned 0'O in.(0-15 cm)from the end cf the hood to the tip a(the nozzle.See Figure 9. ,4q(5-10 CM) MAXIMUM OCID20 FIGURE 9 SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-9 4-1-06 REV.8 Fryer—Single Nozzle Protection (Continued) Maximum Area Dimensions—Single Nozzle Fryer Protection (Continued) Max.Size Max.Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location 19.5 in.x 19 in. 19.5 in.x 25 3/8 in. 290 13 in.to 16 in. See Figure 17 (50 cm x 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in.x 19 in. 19.5 in.x 25 3/8 in. 3N See Figure See Figure 18 (50 cm x 48 cm) (50 cm x 65 cm) 18 ► 18 in.x 18 in. 18 in.x 27 3/4 in. 3N 25 in.to 35 in. See Figure 19 ►(46 cm x 46 cm) (46 cm x 70.5 cm) (64 cm to 89 cm) I I I I I I ,-- I TOP OF FRYER I I I FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA x 3 IN. (7.6 cm)FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND t 1 RIGHT-TO-LEFT 00000a IN.(2-5 cm)FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND oeoolu CENTERLINE AIMED AT THE MIDPOINT OF THE COOKING AREA. FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD FIGURE 17 NOTE;3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE CMOs AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 19 34 IN.(86 cm)MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA 21 In.(53 cm) 1`J ; MINIMUM VERTICAL ) �� I NOZZLE ) HEIGHT ! FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA FIGURE 18 002287 ' . . . . SECTKjNN — 'SYSTEM DESIGN ULEX3470 ULOEX347u Page4-22 REV.5 71'Oo Chain Broiler Protection The following listed protection guidelines can be applied N any Overhead Chain Broiler Protection manufacturer's chain broilers, U the chain broiler meets the»paoi- ,The R-1O2 system can use two 1VV Nozzles(Part No.4183O0)for Uedponomotes Chain hmUomoU|idcatalytic �emcan ' ''y ~~'`~ overhead chain broiler [xotoctiun The nozz�8p� stamped with be �c�dkommm/heodun�gmud�specific �oUon� 1 /ndioo§ngthat this ioanne-O''nozzle and must bocounted tifi--- in the "Specific Application^ ^ by '~~~~' section in ~/~^`''' au one flow number. Design. Or, they be.protected with standard IN nozzle hori- zontal chain broiler protection with the nozzles positioned at either Overhead protection is only mmi/ubh for chain broilers with end of the chain broiler openings. Refer to the Horizontal Chain exhaust opening dimensions that are not \oom than 60Y6 of the Broiler Protection section for specific design information. internal broiler length and not less than O0%cf the internal broiler width,Uoa minimum size n/12 in.x12 in.(3O.ox30.5om),Internal Horizontal Chain Broiler Protection broiler size can not be larger than 32 in.x34 in.(O1x8Vum). | The R 1O2 systemcan use two I Nozzles(Part No. When overhead protection isused, the nozzles must be oen0anod ,horizontal chain broiler protection.The nozzle tip iu stamped 1N. above the exhaust opening within 4to8 in.(1U\o2O cm)ofeach indicating that this is oon*'<lo* nozzle and must Uycounted as other and they must be located 10{o86 in.(25\oO8cm) above one flow number(total of two flow numbers for each chain broiler ~the top o/the broiler surface.See Figure 55. being protected). Two IN nozzles are always needed for chain broiler protection when the hazard area to be protected does not mon( the "Overhead Broiler Protection"requirements.The maximum inter- na|size of the broiler ia43x31 in.(1Ogomx78nozzles must bo positioned at each end n/the enclosed cooking chamber 1Uo3 in.(2.50u[5 cm)above the surface of the chain and a max- imum dietunoeuf4|n.(1Ucm)ewayhomdnobroi|nroponing.The nozzles may be mounted at either corner ao long as they at opposite ends of the chain broiler and positioned |odischarge MINIMUM^ diagonally across to p MINIMUM 4/ w«x/muu/wrenx^L N annuERSIZE UJ nexm/IN. m/"asCM) ' FIGURE 55 N ox'48 ^° The nozzles may vary in position as long as they are evenly spaced from the exhaust center and are always 18O"opposite o[ N ==s each other.If the opening is not square,the nozzles must be posi- tioned along the centerline,parallel to the longest side of the opon- ~ing.See Figure 5O. F|GuRE5o TOP VIEW TOP VIEW ~ FIGURE 58 C00249 Note: The CB Metal Blow-off Cap must be used when using chain broiler protection, MAXIMUM INTERIIAL ooyxmcm) N FIGURE 54 :1 ANsuL Bulletin by Tyco Fire Suppression&Building Products One Stanton Street Marinette, Wl 541432542 www.ansulcom Bulletin No. 5653 DATE: April 29, 2010 TO: All Authorized ANSUL R-102 System Distributors and OEMS's FROM: Product Management— Restaurant Systems SUBJECT: Non-UL-Listed Fire Protection for Conveyor Pizza Ovens The UL300 Standard: Fire Testing of Fire Extinguishing System for Protection of Commercial Cooking Equipment does not currently address a test protocol for conveyor pizza oven protection. However, in many jurisdictions, the Authority Having Jurisdiction has required fire protection for conveyor pizza ovens. In the past, appliances not addressed in the UL300 test standard have been protected by following listed protection options for other appliances with similar operating characteristics. Generally, these appliances presented a more severe hazard than the appliance in question. In the case of conveyor pizza ovens, chain broiler protection was utilized. To confirm recommended protection, we recently conducted a conveyor pizza oven fire test following the chain broiler test protocol outlined in UL 300, substituting fatty hamburgers with a grease coated pizza crust, to emulate the cooking process used by conveyor pizza ovens. Prior recommendations for conveyor pizza ovens larger than the two 1 N horizontal nozzle limitations for a chain broiler, suggested using four 1 N nozzles, each positioned at the end comers and aimed diagonally across the chain within the oven. Based on the actual fire testing, we now recommend two 245 nozzles per conveyor: one nozzle is positioned at the inlet and one nozzle is positioned at the outlet of the conveyor pizza oven on the same side of the oven and aimed at the opposite corners. Utilizing two 245 nozzles as recommended is suitable protection for conveyors larger than the limitations for a chain broiler but not exceeding 38 in.(96.5 cm) wide x 70 in (177.8 cm) long. If you should have questions pertaining to this bulletin, please contact your U.S. District Manager or International Area Manager; or call Technical Services as noted below. Main Telephone Numbers: 1-800-862-6785 or 1-715-735-7415 Customer Services:Press 2 - Technical Services: Press 4 - Training Services: Press 6 - Quality Assurance: Press 8 . . , . . . GECT|ONN — ' B0DBS|GN ULEX3470 ULCEX3470 Page 4-28 RB/O 7-1{9 Nozzle Application Chart The following chart has been developed to assist calculating quantity type o!nozzle required\o protect each duct,plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type ofhazard. Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping Hazard Dimensions Quantity Heights Part No. Flow No. Duct orTransition Leng\h—Un|imitod 1 — 430812 1VY (Single Nozzle) Perimeter—5o in.(127cm) Diameter—16 in.(40.6cm) Duct orTransition Length—Un|imitad 1 — 418337 2VV (Single Nozzle) Perimeter—1OO in.(254cm) Diameter—3170 in.(n1cm) Duct orTransition u — 419337 2YV (Dual Nozzle) Perimeter—15O in.(381cm) Diameter—48 in.(122 cm) Electrostatic Precipitator Individual Cell 1 — 413334 1/2N (At Base of Duct) Plenum Length—1Qft(3.1m) 1 — 418335 IN (Horizontal Protection) ' Plenum (1.8m) 1 — ' 430192 1VV (Horizontal Protection) Width—4M(1.2m) 1 — 419330 1VV Plenum 1.2n0 1 — 419338 1VV (Vertical Protection) Width—4M(1.2m) Fryer(Splitor Maximum Size Non-Split Vat) (without drip 15 in.(uucm) / 13-10in. 419042 280 Low Proximity (33-41cm) Fryer(Split or Maximum Size Non-Split Vat) (without drip board) 14m ;uo 1 1e-27in. 419342 290 Medium Proximity (41—V9cm) Fryer(Splitor Maximum Size Non-Split (without drip board) High Proximity 1 u7-47in. 419338 230 Medium Proximity 1 cU-27in. 413340 245 Fryer(Nun'3p|(t Vat Only) Maximum Size (without drip board) 1e1/oin.(4o.5 cm)x 19 in.(482cm) High Proximity 1 21 —84 in. 413338 3N Low Proximity 1 1O-1Oin. 419342 280 Maximum Size (without drip board) 1Oin. x18in.(457om) High Proximity 1 oa-85in. 419338 3N (64-88om) °' For="u*"nozu°protection v/single fryers,see detailed mmfm"*°=Pages^'m and w/. . .. . . . . SECTION N — SYSTEM DESIGN ' ULEX347o ULC EX3470 Pago4-23 7'1-09 RB(O Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nuzzle Stamping Hazard Dimens!Qns Quantity Heights Part No. Flow No, Fryer(Non-Split Maximum Size ' Vat Only)* (with drip board) (Fry Pot must not exceed 15 in.x 14in. (38 cmx88umD High Proximity 1 27-47in. 419339 280 Medium Proximity 1 c0-27in. 419340 245 Maximum Size (with drip board) (Fry pot side must not exceed 19 112 in. (4S.5 cm)x19 in. (4O.2um) High Proximity 1 21 -84in. 419338 5N Low Proximity 1 13-1Oin. 418342 290 Maximum Size (with drip board) 1O in.(45.7cm) x273/4 in.(7V.5cm) High Proximity 1 25—D5in. 413338 3N (O4-8g cm) Fryer(Split or Maximum Size Nmn'Op|itVa0 (with drip board) 21 in. ) 1 13-18in. 419342 290 Low Proximity (33-41cm) Fryer(Split or Maximum Size Non-Split Vat) (with drip board) 14 1/2in 07 x 281/2 in. 1 10-27in. 419342 280 Medium Proximity (41 —09 cm) ~Range Longest Side(High Proximity) 1 3O-40in. 419335 IN 32 in.(B| cm) (7O-1O2cm) Area—O84 sq.in. (2477aqcm) Longest Side(Low Proximity) 1 15-2Oin. 419335 IN 24 in.(G1cm) (38—S1cm) � Area—432in.0 � (2787omu Longest Side 40-48in� 419333 IF 28 in.(71cm) ) Area—336 sq in. (WithBookoho|V (218Ooqcm) Longest Side(High Proximity) 1 4O-5Oin. 418340 245 2O in.(7icm) (102-127cm) Area—O72sqin. (4385aqcm) Longest Side (Medium Proximity) 1 nO-4Oin. 419341 280 @2 in.(81 um} (7s-1Uzcm) Area—7OOoqin. (4S55sqcm) ~' For multiple nozzle n°*"tio"m single fryers,see detailed information=Pages 4-m and w/, SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-30 REV.4 7-1-09 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping— Hazard Dimensions Quantity HeightsPart No. Flow No. Range (Continued) Longest Side (Low Proximity) 2 15—20 in. 419342 290 36 in.(91 cm) (38—51 cm) Area—1008 sq in. (6503 sq cm) Griddle Longest Side(High Proximity) 1 30—50 in. 419341 260 48 in.(122 cm) (76—127 cm) Area—1440 sq in. (perimeter (9290 sq cm) located) Longest Side(High Proximity) 1 30—50 in. 419342 290 30 in.(76 cm) (76—127 cm) Area—720 sq in. (center located) (4645 sq cm) > Longest Side (High Proximity) 1 35 — 40 in. 419335/435672 1 N/1 NSS 36 in.(91 cm) (89—102 cm) Area—1080 sq in. (perimeter located) (6968 sq cm) Longest Side 1 20—30 in. 419342 290 (Medium Proximity) (51 —76 cm) 48 in.(122 cm) (perimeter Area—1440 sq in. located) (9290 sq cm) Longest Side (Low Proximity) 1 15—20 in. 4193336 1 W 26 in.(66 cm) (38—51 cm) Area—533 in.? (center located) (3439 cm2) Longest Side (Low Proximity) 1 10—20 in. 419337 2W 36 in.(91 cm) (25—51 cm) Area—1080 in? (perimeter located) (6968 cm2) Longest Side(Low Proximity) 1 10—20 in. 419343 2120 48 in.(122 cm) (25—51 cm) Area—1440 sq in. (perimeter (9290 sq cm) located) Chain Broiler' Longest Side—34 in.(86 cm) 2 10—26 in. 419336/432527 1 W/1 WSS (Overhead Protection) Area—1088 sq in. (25—66 cm) (7019 sq cm) Chain Broiler Length—43 in.(109 cm) 2 1 —3 in. 419335/435672 1 N/1 NSS (Horizontal Protection) Width—31 in.(79 cm) (3—8 cm) Gas-Radiant Char-Broiler Longest.Side—36 in.(91 cm) 1 15—40 in. 419335/435672 1 N/1 NSS Area—864 sq in. (38—102 cm) (5574 sq cm) >Electric Char-Broiler Longest Side—34 in.(86 cm) 1 20—50 in. 419335/435672 1 N/1 NSS Area—680 sq in. (51 —127 cm) (4388 sq cm) Lava-Rock Broiler Longest Side—24 in.(61 cm) 1 18—35 in. 419335/435672 1 N/1 NSS Area—312 sq in. (46—89 cm) (2013 sq cm) Natural Charcoal Broiler Longest Side—24 in.(61 cm) 1 18—40 in. 419335/435672 1 N/1 NSS Area—288 sq in. (46—102 cm) (1858 sq cm) . . ' GECTONN - SYSTEM DESIGN - ' ULEX347O ULCEX347n Pagmf31 7-1-09 REY7 ' Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping Hazard Dimensions Quantity Heights Part No. __ Flow No— LsxaBnokorNatural Longest Side-DU in.(7Ocm) 1 14-4Oin. 418338 DN Charcoal Char-Broiler Area-72Ooqin. C3O-1O2cm) (4045aqcm) Wood Fueled Char-Broiler Longest Side-8Oin.(76om) 1 14-4Oin. 41e338 8N Area-72Uaqin. (30-1n2cm) . (4645aqcm) Upright Broiler Length 32.s in.(82.ncm) c - 418834 1/2N Width-3O in.(7Ucm) S�uman�� Length 29|n.(74om) 1 - 419335 IN Broiler Width-1Oin.(41 cm) Length-31in 1 - 419833 IF Width-15 in.08cm) � � 1 - 419335 IN Width. .~.in.~.cm) Wok 14 in.-3O in.0G-7Ocm) 1 J5-45in. 419841 260 Diameter (OS-114cm) 3J5-8.0 in.p].5-2Ocm) Deep � 11 In.-24in.(28-61 cm) 3V-4Oin. 418335/435072 1N/1NS8 Diameter (70-102cm) 3.D-6.0 in.(8-15.2cm) Deep ' Minimum chain broiler exhaust opening-/u in.,o in.(3/u",mcm),and not less than 60%m internal broiler size, ^ . � ^ . . SECTION |V — SYSTEM DESIGN ° ULEX3470 ULCEX8470 Paga4-47 7'1{0 REV.5 TANK AND CARTRIDGE REQUIREMENTS For higher total flow numbers (23bo11o). multiple cartridges and Once the hazard analysis is completed and the total nozzle flow regulated actuators are required oo shown in the System Selection numbers are established,the quantity and size ofagent tanks and Guide in Section |X—Appendix. cartridges needed tn supply the nozzles with the proper volumes ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS uf agent a|the proper flow rates can bo determined,For cartridges used in the regulated release mochaniam. flow capacities, tank This section contains the guidelines for installing the actuation and quantities and sizes, and regulated release cartridge options are expellant gas lines between the regulated release mechanism rog' givaninthetab|ebelow. u|en»r, each regulated actuator regulator, and each agent tank. Total Quantity and Regulated Release These limitations should be considered when u*|*chng the com' ponen�mounUng locations. Flow Size of Cartridge Options . Nucnboero* Tank(s) Nbuocien Carbon Dioxide The actuation gas line in the length o/pipe and/orh that is run 1 — 5 <1) 1.5 Ga||on ��2OR 1U1 10 from »i\ha' the AUTOMAN Regulated Ro|oeee Assembly or the ' ' Remote Release AuaamU|y that directs high pmooum from the 0-11 (1)3.0Gallon LT-8O'R 101'20 cartridge in the m|ooao N actuate one or more additional 11 -18 (1) 1.5Gallon Double 101'30 Regulated Actuator Assemblies.The actuation gas line can consist (1)3DGallon o|1M in.Schedule 4U black iron,ohnomo'plateg.stainless steel,m 16-22 (2)3.OGallon Double 101'30^~ galvanized steel pipe and fittings,and/or factory supplied stainless o\oo|bnaidndoc�uotinnh000 10-22 (2)3.OGd�n Double — � (Manifold) The expellant gas line is the length of pipe that is run from the -22-33 (3) 3.0Gallon Double — regulator in either the AVTOMAN Regulated Release Assembly or a Regulated Actuator Assembly that directs regulated pressure ko When one or more mgu|ekod actuators are used, the following the agent storage tanks m pressurize the tank and discharge tho tank and cartridge combinations apply fo r for agent.The expellant gas line shall consist of1/4 in. Schedule 40 Regulated Actuato Regulated Actuator black iron,ohmmo'p|ubad.stainless steel,or galvanized steel pipe Tank Cartridge and fittings. (1) 1.5Gallon LT-20'Rur101'10 Actuation Gas Lioe'-6 toD°Tanks Maximum (1)8.OGallon LF30-Ror101'20 ^u Tank maximum reflects the utilization mo tank regulated actuators. ) 1.5Go||unand [T-A'101'30or101'30^^nr 1 Use 1/4 in Schedule 4O black iron, hot-dipped ga|va U)3OGuUon double � � ' - ' ' nized chrome-plated,orsksin|ooan(oo|�poamdQU (2)3.0Go||nn [F/-1O|'O0or1O1'3U^^or ' ' oyu� double tank 2.Tho actuation gas line piping is installed from the regulated ~(u)O.0 Gallon(/Wanib(d) [FA'1O1-3OorDouble e|eaao mechanism to each regulated actuator connected ~(8)O.OGa|/on LF8,1O1'3OorDouble within the system.The total length of the actuation gas line .,— hnmthe regulated release assembly m\h�regulated actuator For exceptions m maximum flow "pnnp�" n�" ° *m,/�nm aasenb�(i must not 2OK (O m) wben using on=mz"nmmx�m�=smmmm°mm LT-26R. an LT-30R nitrogen cartridge, or o 101'10 or a 'The 1moo cartridge can not be used when vv*°o.0 gallon tanks are m=ifommtogether. , 101£n carbon dioxide cartridge.See Figure 1NI REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS LINES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS REGULATED ACTUATOR ASSEM ACTUATION GAS LINE WITH AN LT-20-R, MAXIMUM LENGTH OF 20 FT(6 m), MAXIMUM NO.OF FITTINGS 9 REGULATED ACTUATOR ASSEMBLY REGULATED RELEASE ASSEMBLY F|GURE1u0 OW775 i Pre-Engineered Restaurant Fire Suppression Systems Report SERVICE COMPANY 1. All appliances properly coveredw/correct nozzles Fire Fighter Inc. 2• Duct and plenum covered w/correctnozzles _-- 3. Check positioning of all nozzles PO Box 888 4. System installed in accordance w/MFG UL listing c- Land O Lakes, FL 34639 5. Hood/duct penetrations sealed w/weld or UL device 4- 813-996-6469 6. Check if seals intact who evidence of tampering t-- Lic.#01350500011997 7. if system has been discharged,report same C U STD E R 8. Pressure gauge in proper range(if gauged) Name ~ZZ(J� 9. Check cartridge weight(if applicable) Address el 10. Hydrostatic test date 11. 6-year maintenance date Qom'- City >nk State Yj_ Zip 12. Inspect cylinder and mount Telephone I Store No. 13. Operate system from terminal link Owner or Manager 14. Test for proper operation from remote 15. Check operation of micro switch ANNUAL SEMI ANNUAL TIME IN A FM 16. Check operation of gas valve 17. Clean nozzles RECHARGE INSTAL AL TON RENOVATION 18. Proper nozzle covers in place 19. Check fuse links and clean LOCATION OF SYSTEM CYLINDERS p ] �A cJ y� A,(J, 20. Replaced fuse links MANUFACTUR R MODELNUMBER WETCHEMICAL DRYCHEMICAL 21. Check travel of cable nuts/5-hooks () 22. Piping and conduit securely bracketed CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE 23. Proper separation between fryers and flame i- 3 0 31 :::] 24. Proper clearance-flame to filters FUSE LINKS360 FUSELIL�(S45o� FUSE LINKS506 OTHER 25. Exhaust fan in operating order = MANUFACTURER'S MANUAL REFERENCE 26. All filters in place 27. Fuel shut-off in on position _ PAGE NUMBER: DRAWING NUMBER: DATE: 28. Manual and remote set/seals in place �-- LAST HYDRO TEST DATE LAST RECHARGE DATE SERIAL MBER 29. Replace system covers a x ry Fv--• '/a 76 l- FUELSHUT-OFF ELECTRIC GAS SIZE-L c 30. System operational and seal in place 31. Slave system operational 32. Clean cylinder and mount b . COOKING APPLIANCE LOCATIONS:LEFT TO RIGHT 33.' Fan warning sign on hood Dom_ 34. Personnel instructed in manual operation of system -- a �e 1-5 35. Proper hand portable extinguishers y" 36. Portable extinguishers properly serviced 37. Service and Certification tag on system NOTE DISCREPANCIES OR DEFICIENCIES BELOW On this date,the above system was:("No"answers require an explanation) 1.inspected and maintained in accordance with procedures of the presently adopted editions of NFPA 17,17A,and the fire protection system requirements of 96. Yes No 2.Inspected and maintained in accordance with the manufacturer's manual and the manufacturer's specifications. Yes No 3.UL 300 compliant. t Ye No 4.Connected to an alarm. Yes No 5.Hazards were unchanged from last inspection/maintenance. e o 6.Displayed proper signage for remote pull(s). Yes No 7.Displayed proper signage for Class K portable extinguisher. Yes No S.Tagged in accordance with Rule 69A-21.303,F.A.C. Yes No COMMENTS: S V C)V.. The setvicejecrnician certifi hat rsonaNy inspected and found conditions to be as Indicated on this report. SERV TECKMON E DA6 I TIMEOUT AM1 M 43 ER'S AUTHORIZED AGENT SIGNATURE PRINT SERVICE TECHNICIAN NAME PERMIT NO. PRINT CUSTOMER'S AUTHORIZED AGENT NAME WHITE-CUSTOMER COPY YELLOW-DISTRIBUTOR PUIK-AUTHORITY HAVINGIURISDICfION CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20822 LP/NATURAL GAS PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20822 Address: 5897 GALL BLVD Permit Type: LP/NATURAL GAS ZEPHYRHILLS, FL. Class of Work: FIRE-LP/NATURAL GAS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 10-26-21-0020-00000-0090 Improv. Cost: 2,000.00 OWN ER.INFORMATION Date Issued: 2/15/2019 Name: ZEPHYR II LLC Total Fees: 125.00 Address: 7162 READING RD STE 730 Amount Paid: 125.00 CINCINNATI OH 45237-3845 Date Paid: 2/15/2019 Phone: :Work Desc: INSTALLATION GAS LINE PIZZA HUT CONTRACTORS APPLICATION FEES GAS MASTERS,INC. GAS FEE 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 25.00 FIRE SITE INSPECTION-Final Ins ections Required Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FIN LACING, CONS LT WITH YOUR LENDER OR AN ATTORNEY BEFORE R COR ING YOUR NOTICE OF COMME ENT,; t�4 L� ino — twj�� CONT CT SIGNATUR PERMIT OFFIC60 PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application \\ Date Received Phone Contact for Permit Owner's Name l��I�fJ�le�'J Owner's Phone Number Owner's Address a(3 5 1" ( (SoR Y,S Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address' -3 Q 9 &ALL L 1/ID ZbP+ h k 's L 335 y�L Lot# Sub Division Parcel# Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum ood Installation Emergency Generator<30 kw LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL / ❑®y emi ®n ter ❑ Sprinkler ❑ ❑ ❑ Recreational Bum (/ Fire Alarm ❑ ❑ ❑ Sparklers Hood Cleaning 1:1 ❑ ❑ ❑ 1:1Sprinkler System Installations JvV l�C� Hood Suppression ❑ ❑ ❑ ❑ El Standpipes(Sprinkler Sys) Fire Alarm Installation Torch Roofingrrar Kettle 0 Fire Pumps Waste Tire Storage ANNUAL Flammable Application-ANNUAL �= Valuation of Project Fuel Tanks Q Other: Contractor Company Signature F Registered Y/N Fee Current Y/N Address I License# ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address License# PLUMBER Company , C Signature Registered Y/N Fee Current Y/N Address AJS1� (S(_ D License# FUZ -?= MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current Address-1 License# Directions: Fill out application completely. Owner&Contractor sign back-of application,.notarized(Or;`oopyof signed contract with owner) If over$2500,a,Notice of Commencement-is reGuired'.(Mechaoical work over$5000) Supply two(2)setstof drawingswijh applicaple.docu'riientation Allow 10-14 days for review iafter submittal-date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to='deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor-are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco _County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT\%] certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COM ENCEMENT Y RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INT TO OBTAIN INANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N CE F M NCEMENT. FLORIDA JURAT(F.S.117.03) ` OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and savor t ff d efpre this by t/7-1 uy. - L Who is/are personally knownrto me or has/have produced Who's/a personall Known to me or has/have produced as identification. as identification. Notary Public / Notary Public Commission No. Co 6miion No Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped JACQUEUNEBOGES Comm>ssion#GG 276457 .or Expires December 12,2022 �P.` Bonded Tfw Ymy Fain WNm 800.385.70'• ZEPHYRHILlLS FIRE DEPARTMENT 38410 6th Ave Zephyrhills; FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy No.- fie l9v Plan No.: Contractor: D Business Name: Billing Address: Business Address: Business'Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual- Education,healthcare,De tention&Correctional Public Assembly,Business, schools, Storage,Mercantile and Churches Site Plan N/C Industrial. no charge Sprinkler $50. Multi-Family/Commercial .03 sf up to 800 sq ft $ 24.00 Standpipes $50 (Minimum Charge$24.00 801-1,500 sq ft $ 34.52 Fire Pump $50 Plan Revisions DBL 1,501 -2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,50I-5,000 sq ft $ 127.52 LP $50 0-25 Heads $50 5,501-7,500 sq ft $ 187.52 Na:eakk s $50 26 plus Heads $100 7,501-10,000 sq ft $ 262.52 us- per tank $50 STANDPIPE.SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 Per Riser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation; $25 Per Pump $100 30,001-40,000 sq ft $ 1,050.02 Controlled Bum(15da: $100 FIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,500.02 Hood/Duct $50 0-25 Devices $50 60,001-80,000 sq ft $ 2,100.02 Place of Assembly $50 Annual 80,001-($2,100.02)per 26 plus Devices $100 ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS (Business closed until Flammable Application $50 Annual Wet $50 violations corrected) Waste Tire Storage $50 Annual Dry $50 SPRINKLER SYSTEMS Generator<KW $100 CO2 $50 Hydro Undergrounds $45 Generator>30 KW $100 Other $50 Hydrostatic Test $65 per system. Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Acceptance Test $45 persystem Fumigation Tenting $50 Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50 Annual FIRE ALARM SYSTEM t�uel Tank Installatt 0 System Acceptance $50 er Tank $50 Recall Acceptance $50 atu_m as Installation $ OTHER (Per System) Fire Wall/Smoke Wall $15 perwan Spray Booth $50 s per tank atural Gas $25 per system Tent 10'x10'or greater $15 per tent Fire Pump $45 Fire Suppression $30 System Acceptance Exhaust Hood/Duct $30 Re-inspection DBL (other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS TOTAL INSPECTION TOTAL PERMIT TOTAL GRAND TOTAL Comments: Date: Inspector: see back nm FALSE ALARM FEE 1st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 R6th Alarm $200 NON COMPLIANCE $150 Cont.Annual Inspection Fees 3-11 Units price per unit $ 5.36 12-25 Units price per unit $ 4.82 26-50 Units price per unit 4 4.29 61-100 Units price per unit $ 3.75 .100 or more Units price per unit $ 2.68 Fire Safety re-inspection types First Re-inspecdoi N/C Second re-inspect $75 Third re-inspectior $ *125.00 Inspection scheduled but cancelled 24 hrs $ 50.00 TOTAL fith CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20359 PLUMBING PERMIT,567 PERMIT INFORMATION LOCATION INFORMATION Permit#:20359 Issued: 10/22/2018 Address: OK GALL BLVD Permit Type: PLUMBING HYRHILLS, FL. Class of Work: PLUMBING/NEW Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 14,000.00 Total Fees: 110.00 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 110.00 Date Paid: 10/22/2018 Parcel Number: 10-26-21-0020-00000-0090 CONTRACTOR INFORMATION OWNER INFORMATION Name: J & S PLUMBING INC Name: ZEPHYR II LLC Addr: 10184 FISHER AVE STE A Address: 7162 READING RD STE 730 TAMPA, FL. 33619 CINCINNATI OH 45237-3845 Phone: (813)655-6677 Lic: Phone: Work Desc: INSTALL INTERCEPTOR (GREASE TRAP)- PIZZA HUT APPLICATION FEES PLUMBING FEE 110.00 INSPECTIONS REQUIRED 1ST ROUGH PLUMB 2ND ROUGH PLUMB SEWER WATER FINAL REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. C94,fRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER staasaoozo . City of Zephyrhills Permit Application �:�"8�3��80 0021 Building Department Date Received O 2 ' _ d rx _ Phone Contact for Permitting D Le Owner's Nam® ?j Owner Phone Number Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS - l �v D . LOT# SUBDIVISION 116 PARCEL ID# - !.t V ZO • 00000 DAD (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR = COMM OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ 000•oa =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING = SPECIALTY L J OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y Address I nose# PLUMBER C NY IAAf�•13114 CT I ! `" ` • SIGNATURE �E1GI TERED Y/ N FEE CURREN Y/N Address m a {-+ License# CFC, a' MECHANICAL COMPA SIGNATURE REGISTERED Y/ N n Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREn I Y/N NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to'deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he Is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which I*hey will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and Is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified In Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource-Recovery Fees must be paid prior to receiving a'certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work Is$2,600.00 or more,I certify that 1, the applicant, have been provided with a copy of the 'Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant Is someone other than the"owner".I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTORVOWNERIS AFFIDAVIT: I certify that all the Information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application Is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be In compliance, Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Welland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone'V"unless expressly permitted. - If the fill material is to be used In Flood Zone "N', it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone'A"In connection With a permitted building using stem wall construction,I certify that fill will be used only to fill the area Within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan Is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically Included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit Issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S,117.03) OWNER OR AGENT CONTRACTOR Subscribed and swom to(or affirmed)before me this Sub It It nd swo to 2g,rl—�e�� 0 7 _4W by by N,244 M_ Who is/are personally known to me or has/have produced 1 ge personally known to me or has/have produced asident1ficallon. :pk. as Identification. _Notary Public Notary Public Commission No. Commission N — 3XJ4WAt141t6 Name of Notary typed,printed or stamped Name of NotaQf typed,printed or stamped SKYLER M SUTTLES My COMMISSION 0 FF224747 EXPIRES April 27 2019 A �U r�aKrue City of Zephyrhills BUILDING PLAN REVIEW COMMENTS k Contractor/Homeowner: Date Received: /O Site: 9 Permit Type: ( Approved w/no comments:❑ Approved w/the below comments: - Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or pla lC Bill Burgess— "lding Official Date Contractor and,16r ftomeowner (Required when comments are present) ELECTRICAL SPECS. 5415/16'BACKER (1)LED 60W 12V POWER SUPPLY 0.9 AMPS EACH(INPUT) 51" TOTAL 0.9 AMPS 0 100-277 V A ALUM.BACKER SEAL ALL PENETRATIONSI "USE(1)20 AMP CIRCUIT ., „ PLASTIC TRIM CAP W/SCREW ~ LED MODULE(TYP.) (6)3/8"DIA.FASTENER w/BLOCKING(AS REQ'D) SEE CHART FOR ANCHORS BY WALL TYPE ® ® ® ® p7/8 DIA.ELECRICAL INLET IN BACK OF RATCEWAY(TYP.) USE PVC SLEEVE WALL FINISH(IF COMPRESSIBLE ) 7/16"DIA.MOUNT HOLE SEE ANCHOR CHART FOR MOUNTING OPTIONS III IN FLANGE OF RACEWAY(TYP.) I p ® p ® p • RACEWAY w/SERVICE COVER CONDUIT TO REMOTE POWER SOURCE (INSTALLER TO PROVIDE UL LISTED CONDUIT& 0- FITTINGS,AND MOUNTING HARDWARE) w p Tp ® p p p Q (1)7/S"DIA.ELECTRICAL ROUTE HOLE m POWER SUPPLY MOUNTED ;o I ° O INSIDE RACEWAY n p p ® Tp p - j h ' SIGN FACE LED MODULE p p [Ts1• p p p WALL STRUCTURE (T.B.D.BY INSTALLER ON-SITE) ALUM.BACKER ® p p p p p WEEP HOLES NOTE:DETAIL SHOWN MAY NOT REFLECT THE ACTUAL WALL CONSTRUCTION AS WALL TYPES VARY PER SITE.IT IS THE INSTALLER'S RESPONSIBILITY TO IDENTIFY THE ACTUAL A DRAIN HOLES(TYP.) 1T CONSTRUCTION AND ADAPT THE 44 RACEWAY 1INSTALLATION ACCORDINGLY,SEE CHART IJ{ FRONT VIEW (w/FACE) FRONT VIEW (w/o FACES) WALL SECTION"A-A" SCALE 1:16 SCALE 1:16 SCALE 1:8 . GENERAL NOTES INSTALLER TO PROVIDE COMPLETION PHOTOS OF MOUNTING/CONNECTION POINTS,WIRE ROUTING AND OVERALL ELEVATION. SIGN MOUNTING HEIGHT TO BE 30FT MAXIMUM THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ANCHOR TO BE THRU BOLTS IF POSSIBLE,ALTERNATE ANCHORS PER ARTICLE 600 OF THE NATIONAL ELECTRIC CODE AND/OR OTHER APPLICABLE LOCAL,CODES. WALL TYPE SHOWN BELOW FOR USE IF THRU BOLTING IS NOT POSSIBLE THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. ANCHOR SCHEDULE: 3/8"DIA.ANCHORS THIS DRAWING IS FOR INSTALLATION PURPOSES ONLY AND NOT TO BE USED FOR MANUFACTURING. INSTALLER TO VERIFY SIGN IS PROPERLY INSTALLED,CONNECTED AND GROUNDED. WALL STRUCTURE ANCHOR TYPE FLORIDA BUILDING CODE �Q• BI E�FjVA WOOD BLOCKING LAG BOLT(3'EMBEDMENT)THRU BLOCKING 6TH EDITION(2017) INSTALLATION INSTRUCTIONS 1. OPEN PACKAGING CAREFULLY AND INSPECT FOR DAMAGE.IF DAMAGE IS FOUND, EIFS OVER 5/8"PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT MEN SLEEVE SECTION 16 WIND LOAD Q �y CLAIM MUST BE FILED WITHIN 5-DAYS WITH SHIPPING AGENT. HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-12'EMBEDMENT) ASCE 7-10 Q LICENSE 2. DETERMINE SIGN LOCATION AND TAPE UP THE PROVIDED TEMPLATE ON THE SURFACE TO WHICH IT WILL BE INSTALLED,RECEIVE CONFIRMATION FROM CLIENT OR SOLID CONCRETE WEDGE ANCHOR(2-1/2'EMBEDMENT) 150 MPH WIND LOADII #52949 CONTRACTOR. CMU,SOLID CONCRETE,BRICK HILTI HET ROD W/HY-20 ADHESIVE(3'r4'EMBED6ENT) RISK CATEGORY II 3. LAYOUT AND PRE-DRILL ALL MOUNTING AND-ELECTRICAL HOLES REQUIRED FOR MOUNTING THE RACEWAY TO THE WALL. EXPOSURE C \ \4. FILL ALL HOLES WITH SILICONE PRIOR TO MOUNTING THE SIGN. STATE OF 5. ALIGN RACEWAY TO MATCHING PRE-DRILLED HOLES WHILE INSERTING FASTENERS ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE THROUGH RACEWAY,WALL AND BLOCKING(AS REQ'D).FASTEN WITH HARDWARE.USE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS Q� ���Q► PVC SLEEVES TO PROTECT WALL FINISH(IF REQ'D). ENCON SERVICES, INC. F 6. MAKE FINAL ELECTRICAL HOOK UP TO PRIMARY WIRING OF POWER SUPPLIES THROUGH P.O.BOX 3613 SS DRILLED ELECTRICAL HOLES. SIGN TO BE CONSTRUCTED 1O 2014 NEC 600 STANDARD 7. TEST LIGHT FOR PROPER FUNCTION AND ILLUMINATION. APOLLO BEACH,FL 33572 8. PERFORM TOUCH-UP AS REQUIRED SIGN TO BEAR UL LABEL ® 813-655-3373,FLEE#9394 AARON BIEDENBACH, PE 52949 9. DISC RD ANY MATTERIAL OR DEBRIISCLEAN INSTALLATION WORK SITE FINTO ON ALL SITE DDUUMPSTE AND DEBRIS.DO NOT SIGN TO HAVE ELECTRICAL DISCONNECT ON THE EXTERIOR ENCON@ME.COM DATE SIGNED: 12/20/2018 INSTALLATION DRAWN BY SAJ SITE TITLE o °o PIZZA HUT (NPC) PIZZA HUT 48"LED SWIRL LOGO (CSB48,w/BACKER) °°°°° °° DRAWING DATE 3-29-17 5897 GALL BOULEVARD °0° OQ° 4949 SO.11 OTH ST. THESE DRAWINGS ARE THE EXCLUSIVE 000 00o P.O.BOX 20020 PROPERTY OF EVERBRITE,LLC.USE OF, CHECKED BY RHB ZEPHYRH I LLS, FL 33542 PROJECT NO. DRAWING NO. REV °vo o0O0o o"° G WI 53220 OR DUPLICATION IN ANY MANNER WITH- 360396 IN360396D 3 6039 6 D A J)o 0 0 0 ® 414-529-3500 OUT EXPRESS WRITTEN PERMISSION OF A 3-29-17 SAJ RHB RELEASED FOR INSTALLATION DATE SCALE REF ° o EVERBRITE,LLC IS PROHIBITED. REV DATE BY CHK DESCRIPTION 3-29-17 AS SHOWN gA1gI11w�N.N/M �4101MMw4M �0�4/OO�p•wM4�MgWgtoMlNw�auyMwdodw�MpwwU 1•ggbw.l�WMplwpP�we0iL4AgN1iMMep/wW'wF�MMwgMY�w'gM�NM�wdMRAMCpgq�miNM�+•MW7gMeoiN► IftiNOtlWWN�IVlOU10llllm 313 K190 0113i�AIDv H3 N O ONIddOHS YZY d UAHd3Z MI xI yaMa aNcvy»w�rit'arwrw�o»�ms nI wOSA4R0 8iMi1110� Ubfd®IY 1 Yl'9L''Si `\11II 91t'la�t7tt11/NBI=IION9t10DtNM _ 3NML'>3ro1M AWAMO LlOOM SJN3�O'MO ff3i \\\\\'y"1VNO/84/>/ �. BODOM alwary DafwaaflHM `�.� 4°dplaoj�.�'p�//. VV $9NPINII5t 311 HAHd3Z JWtrk13 LAS cwmsrm slrelrtoo ma -AF sq 31v►s n N ygp 3111M 13" TwoO 3M0 ONOIO4l3N -ON — r • �p Z EEf5S'oN jA`4J I b t II !I ! I !! I ! ! loll Ullt0iL �5, _ !1It � I I IIII hI II! t 5!� � 1!� � wi R i b I!! I! 1 1! 1 h ; j ! !:i! Ii!I& !i 1 Ib o 5 bb� l iLR WiUIdii,liliiflilifflliiiliiiiHil $ Z C ! kuii iii ! / - - !�r I / 4 - ' _ 5 M . . r - -I---.—_______ ——______— - - ---------- I g & Iii I I I / ! �� !' t i t kE g I j r J_ .. Y l 1 I I ' 2 ' ' I ? JI' I V I' I da 1 ice.{` I / � • � I : • r• 1 w >r — 3A0.MAON I . *is e'f" . , ':" ------ ----- I4ti! I 1 �j ii r I I I f I em ` i di t j I j 1 I + RR aW I t ♦ a} s" i I i � r I - • __ I®1III 4- — ____ ____ ____— _________- ____- ____- V a� H-},tier... .:` "r+. '°., " T ". v�' -,-M.j+..� .„ 'e= i �.-3k..'"y.„ T `� c �• .sre `.s. �. Et -- ! t I i miw I I _ • ancau etas fog a wm»nw i _ f - 1 RVAD-GE4EALMOIE8: 1. THIS CONIAACTORSHMLL FUUSHALL LABOR KPBW'BION MATEIA&EQUPMB4L 2W TIE ORAWK6 ANEUBNERALYOIA0~ATICAND,EJUEFTWHERETME61T6ME 4a REFIGHiWTFP64SHW.BE TYPE K HAD OFAWNCCPPER VIOLATE ROTS,ETC.REQUIRED FCRACAAIPLETESYSTEL/CF HEATN({VENILATNDMIDAIR SFIOWH,NEPDTNTENOfDTDBFIUITIE EYACTICGTDN OF PPEB„OUC'IWCRIC tENADERANTRPEWITH W4'MiAWEXq.O9tD CHL NBUATgN CN a E 1 CCNDRMMA4DeSGM ONTIEORNOW.NCLUDNG ALL NECE38MMPARTS, OUTLETS,FOTUfES,CR EQIPIENT. THE SUCTDNLOEMAIRMMWD(CLCSEDC81N9UATDNON LI AGES,ETC,REOUTEDBYSTATECRLIX7IL0O ORTO&111BFAC'MY THEUQUDUYE. g COMPLETE THE NOTALLA10K m ANY OFFSETS N DUCTWORK OR PPNG ORCK%4M N LOCATION CF EQUIPMENT REAUNED OR NECES ARYTOAVON)Nf WITH STRUCTUE ORWRN THE 47. THEON3ROK150®ION PROFM IONALS CONTRACTSEACES DOES NOT a 411.31$110131 OTHERWISE ON THEORMNNOB.MLWOLKSHOWN 04THEKVAG WORK OF OTHERTRU7ESSNNL BE MADE Of THIS CONTRACTOR AT NO ADDITIONAL NCL111.7E CONSTRUCTION pNSESBNICE.THE41ECTiLDESIGN ORMWNOB SHALLBE FUNISHEDAHD INSTMlED BYTH IS CONTACTOR COSTTOTHEOWNER. PROF SSIONAL.MOCRTHE OWRERWILL PROVDE THE CONSTRUCTION a ALLWORK SHALES PURHASEDANDNSTALLM PERALLMPUGBLE INDUSTRY 31. REFER IO BUDMq MD STRUCTURALORMBRIBB FOR ALLONBNI0NS OF BULDING RCHITIF4CE0.ESIGNP&DIi1SOONTRACTORTHE ONEMMARE1TATfl1E STANDAF ,&ALLAPKICABIELOCK,STATED,&MATH LO00M SPACE& C® TFONMACT DOCUMENT NO OI6BFFORS O THE WO TATTN MN-15 OMTRLC DOTJI, INS 4. Mb CBS IRIUCT B OFAHE FTHISPD,E0l YDEIATIONROM THE 81W1TOA STANDADS.KITCHEN HOOD MD EQWJBTOUCTWOLKSHWI BE CMEON NTHE MANUFACTURE OFMFOVWiCAL EQUPMENTOF TYPE AND SIZES ID 1HETRACT DUCUMENTABE DNISIO PROECT.MH D@AUST FTDMIH4E SiEEi@0.051NTf MN NTFIGQ498).FABRICATED AD NSTALLEDIN 100 W74OSE RDDUCI81MV£BEEN NSA19FACTOM LIEN SIMILAR 83131: AUNTRAWDOTLBIRSBY BYTHE ARC ITECT ALDMUST BE AOCOMMICEWITHNFPA9/.SBCMOJMCL DUCYdVOPKSMBINOMNON FORNOTLESSTWNFWEYEMB AUTHOR"iALMO RP/E MOMISWOF ECEDELO11011 ORW4fK6ARE NIEIOR d►ENBI0N4. NCORPOR TEDNTOMSPRDJFOT.ONINCN-ISCONIRPC1OR68HMLLBE 2 3a 111.318 SPEOR ALLVPOCAMEDOTHEMISE 141NE81111 RGO1016CRON1HE HELDWHEWRALL OEWATIONS FROM THE CONTRACT DOCUMENTS, a DUCTWORK LOCATEDNSDEOF BUDNG.EXCEPT HOODEJOWST DUCT,SHN.LBE O 11I*0*,ALL EQUPMENT*0 MATERIAL SHAL BE ISTALLEDNACCORDANCE IECOfDEDOR 1NiECOROED.THHATHAVE NOT B®I AUTHM=NO ''^^ N13IWLYNSUATED,I8UATE ALLRECIANGULMOUT8OEAFL 8IFPLYAFL NO WITH 11€89TRECCM.E.DA110H6 OF THE MANUFACTURER OF THE EQWMENT. APPROVED BY THEARCHRECRIRAL D9KN PRCFTSSIONALANGORTHE V O RETURN M TICRWOKWITH L1.111C34 NATO,FL DENSITY DUCTLIHER EQUAL TO MDWtARYPPNG,ELECTRIC CONECTIONS,ETA.IECOMUU BY THE FBB[iV&A1 TS RUIERBE DUCTJOI &WL BEBE&EWTHMASRCOR MASTIC PLUS M0NUFKAUREHOR REOLWIM FOR PR PER OPHNTION B*4AU 8EFIRNISHED U Z LL TAPE ROUNDDJCTBHWLBE E)OEW44LYNKAATEDWRH2 IHOL 316Q FT.DENSITY MONS'TALLEDCOMFIETE ACOPVOF1FE MN&1131148NWTALLAIION 4S. THEDMMRUSMENTENDEDASOBOMOPLYMDNDDATETHE DIKEWRM EOU.T0FB6iaA8TYPEARCHDMEOWBTOUCTSWILLBEE7TEF WLY RSCO NOT WRMVAO WITH FIRBAA81Ei14lWA/ZION NOTOD8AWSE PROMOED)AS REQUIRE,N AND 81431.11 AVMABlE 1O THE ENGINEERS REP294TATh€AT4LL1DEN. Q01ETITJIE940P DRAWNGSM0940LXDNDTOE LOMASSUK DIVEIM OROERTOAffT"APPUCABLEOO M 15 Sc KJPEATNG MWNTEIAAOEA11o8EAA10E 0R%MNS8AFEGEEA LYDLt4PA MWLCMO,EXCEPTMNETE j a INBCOMTFVCTORSIWE AJRN3HMONSTKLALLSTMTTEPADM011 CT$41 J. ANALPAYLENLINBt10*OF11/WE DUCYWWOAC OJT1EIB,F I ORFOR T. CDITIHOIDEVICFBp1OTafl 8EPRWOEIFORALLNVAC.EQUIPMENT.SWIRKAI. CONTRAOOR8HW_CCWPWEANDCEJKRFOURNDE®,HARDOOVM THEMOSIECRIRN.DESINP ONES.THE OWNINANDTHE CONTRCTORWWL FLWHW&NSTALLALL POWERY 19 THB CONTRACTOR SWILL TRRE&FII10 BND�CON1TAININO: DMSICNN500N1RPCTORIS)ACKNOWtMGENOLNDERBTND THAT THE FURNISH&16TALLALLCCNTROLWRNG MsJ VIi1&W18EINSTALLEDN CONDUIT. L W1MES.ADDRESSES,MOIEEAONEMABERSOF1HISCONTRACTORMD CONTRACTOOQIWB4BPoR0NBD4-ISVX KNNYCONTAINERRCRB, 7. GEEFAL COHTRAC ORWWLPROHOEALLREQUIREDOPE INGS 1S, 4*0.A1CNCIWfl01FR N FLOWS NO EXTEIOR SE VIMCOWPA ES, 9YBfE.B NBTALUl10N 8UBCONTfWCTgB. � VAL BECORFECTEDWHE 4 3AILBFOR NSTMIAIONOF HVAQ Ef%1PMEJL PPNGMDHOROUCIWTR( X DRAWINGS VB'EI-T)YA7HITEAB OEIIIAE)8Y . a CONDENSATE ORHN PIPE SWWL BE8QU 40 P.V.C.NBUATEDWITH IY2411.WL 7L E MMANFACTLMRSD WnMUTEPoOURE,FNALAPPROVEDS"DRMWWA COMRAC1OOIXRBI18N)RRORTATONCEN1WRROTO1HE TENON. OR EO1AL.I SIATON.MN.S0.SHILLL BE 3H'. PEfFORMANCEDATA CURA9,RATNGS,pMaMM6,SPARE PMTS NO 1509ON PROFEIBIONALNNYDEIOE CM THECONTFVCTOR(O MAY 11311}EN4 101104.11 a UNOOCUIMAMBET NOISE LEVEL FOR NVAC.SYSTEM SHALL BE NO MORE THAN REPIJIOB.E4TPMBI$78,MANUALS ON AF00PERA7ING NBTXOT016, �TOLIK:VH7-iS�THE TXXMEN18AND REPORT ' 11RJ IV 4 ANDS6MCE MNAW$FOR 1404 311148 14145(110 014 M•A•WBWTED$OALE. A EACH ITEM OF EOUF%NW AT ONCE ANY DEC06SIM 1HET46I00-ISOONTRCTORO,) S.VALVES ANDSPEON.1ES SHALLRES L.VEMLIBORTEDDEFICENT�WTHTHE 1MSION•15 DESIGN 10. PFOVDE1FEilO6TAT-T40NEYWHL'N910N PROCOANF3RTAL 3181111$WITH ELONOA®R- C.OONiROLS 13113131 VL PRIOR 1OMYMDNNGAM'8UBDONIRHC18 OR8TARINOANY WRITE RODC$B G5PPIC. D.SPECALTEMS WOK WITH THE CONRPGTORS OWN E FLOYEBI.IFDEf1OB4CES CANNOT N.WH E E OOAG AM S ARETOOLARGE FOR TNESVGER MRANOE MNlA R0MXI41BI 11. CCMPIr 154TH LOCAL BESMCBRPLN6fEOlIBMFNIB FORALLH✓AC EQAPWIBNT. C31 MMVLFOFW WIEOA730K/6085KTWP GRAD IONMLLA.Ol1E ALLSBBMC SPACIGDEVICES SHALL BESUBMTTEDTOTHE STRUCTUAL ENGIN�i V.S1EP-Hl81EP PROCEDURES FORSIARRXSMOSTOPPI4G 1)1.5181151. ON IRRl5 18WRH40UESSX WND TEORAWTIOML F LL8O AHED FTR REVIEIY.THE W OP ORMWN36 8HN.L WAR THE SFN.OF A UCBiSE PROFESSONA ENGNEER WRHMI4 FIVE YEARS BPEA84CE NTHEDFSKN NCRIAL(X'@T47IONAND IIAIHIIBIANOE NN8IRRUCTION6. WVIBIOK1NITW071PROFEmPEFF-MOIHECTTRACTORSWILL8O PFOORT. WOTK RPEAMFF4 OE810R DFfiC♦EiVC� 3a OF CONTTRACIOAWINGS®04NC OAWNAN 41 FOR E DORON CHANGE CF9EMCBFW;RXR SY8T86.ALL SEISMIC IIIIRINLOIW WITH ALL APAICABLE&IlD11G�' OF CONIRC.T ORAYVMOB.POUTS,ND BFFLIFIGOIOt6 FOR fECCRDNG CHIW(N9 PROFR ro PEt9PTOF N8T8OTONI FRO811€3111044.l5184 D® SIENT WMDETO TIE CROOKSMOSECNXSATIONB DUNG THE CONSTRUCTION PHASE OF HDONEAti) THETRACT 0R�.DEBKitPRO�IONM.WLL 7700ANDPAR.KNE 11 INSTALL HVAC.EfXJPM@JTA8 H01EDONTE OHAWNGa PRONIOE A(%E88ro THBPRCIECL THESETAIMPOSSHALL BEAVAIMEATTEJOBSIIE FOR EDOTMBUL MOSTM1t44* weWNID1113 NMM EQUPWENTPER CODETEOUIRE1NT& EN1RroBACES. DsTRtOTLIW HXRAWI108 FCR DIAE61oR6 OF REVUEAINED14AT NTi.MTFNANDSAUCLEANBt OWNNG6&WLBE BUWLYNGSPACEa PNpHLpWlE7dei CFOWVLCO RWrDRNAVM 4DD8/WL0.10NS.SHOYVANYCHWKE•S FHiOM Ill LM>/71I74Nb 19 M DISTRIBUTION SHWL INICATEORORERMP CONSTUIE PROVIDE OPPOSE CRIGIyLCOMRPCTDRyyN0 N108PE(FIGOONB, BLADEOM.PEBVAETENOK)AIE.MLM.UMNUM CCNB1RUC110I. 49. R9TR00U FKXJIIESSFWLBEVEN71A7M A$NOICATM ON THE DRAYN163. ea THIS CONTCTORBHWL PREPARE,UPON COMLETON OF THE PROJECT,FIAL &PER CODE RA 14. CONTRACTOR 81HLBE 1910149881 FOR ALL WORK FTRIO PROPLACE NA RECORD DRAWINGS ON REPO0OCBLE DAFTNG MEDA 1071E SAME SCALE AS THE 50. CAIPUNEWTH ALLAPPLCABIE LOCAL STATE.MD NATIONAL 0001854 SATISFACTORY AN NEATWORIOMNIE MMWER N EVERY PMIICULARTO THE CONTACT DRAW=SHOANGTHE CHANGES WADE ro THE ORAWNM 0INOTHE SPECpGALLY MPFWALOFTHEFNGNEEL PNITF7POBEOUCTWOR4PE1MG1TEcT CONSTRUCTION PHA8EOFTHIS PROJECT.MOTHEDR*110S HW.LSHOWEXACT 1a CONTRACTORBNMLLCONFER WITH ALL OTHERCONIMCTQB REGRDIG THE I€TALLEDBDCAT PENC CONTRA84�S OFMIPPN[LOUCIWOR(SW1LBEDRAE NSTALED LOOM CONiMNS ACLU-OEF OJOI WO*N10LLBIPMENT ION® 51. FREER H40ODe11PPRESBONSY81d1 LOCATION 4110 818 OF PPM,EQUPMENT,FDL1T.EN COHDUUIT,DUCTS,OPEINGS, AF SU0HA8AWALLORCOLUMCBTERUF.1411401.8 SWITCES.MALE7$EEG,NOFEMTI*TTHHEMAYIENONIERFBB4CE P1118010014144401 ORNWMVI 1 NOTBEACCEPTEDVS 11444. X)M MANAFACTU MIKA.WORE ORAPPRO4C•DEQLAL. BEIWBN CbTK1A1KIN OR TIE PRROORf68OF1HEWOIK 014141(XNIFACITT DRAMYI/URa F NAM:WET GBACAL.FIRE EKIINCJUBHIING SYSTEM INCLDING 31. TBTO BE LI.EWI.Y UDERSTOODTHATTHE SYSTEMS 04RIJOE UNDER TMB 80311011. 4T10.)€80,P1ESSUIECYl8OEB.PUUSTATONB,MAIN to THE OWIERAAY CFNCODIT,LOCATION FEET IN Ep1PMETIO PIE FEETMOM7/ GAS SHUTOFF VALVE AND NOQn1S TOPROVOEACO.WLETEAUTOIAIO CO CHARGDUI%IVICRICSUCHCH ETC.,AR MADE RIOOIECIIONLARKIUTEXTRA TESTS HVEBEE81ECFK`i NIDE3IN ANDSINOC T8DUOWIS COMPLETE.AN FIRE ETI0U6FAN09YBTEMN CONFORMANCE WITH NFPA NAND U.L CNA4OE.PROVO IPMENT GWq,194 MADE RIOTroNBTAl1ATHO OF THE IN HAVE*14 MICE.FI EGNTNGMOBIWNNLlOWgRCBCOMRETE,MO 308.CONT:N.MLPPING DWEPTTHATWNTi HAS BEE49PEC 7L.Y MEQWK•AlEOUPWBT. 1HEI6TALlA110N6aPBV1TIXi PRCFFJi.Y' APPROVED BY THE OWNERS NOPECTOR. J 17. ALL REFE TOCONT ACORS N SPECIFICATIONS MO DRAWMO68HALL FIEFER 30. 7ONOF00013131108514411TESTS AANDAT0.NE�S NfSUFDT*E 48 IGNATE�•6 TO THE RESPECTIVE TRADE CONTRACTOR PERFORNGTHAT PORTION OF THE WOW ro ENGINERTHTIENBTNIATONPoRAPERODCESAEMr0F8GHT(W �E*101*OJDE Br1FECLOF EXTO0.THECONISTEMF BHIAL1.tE F�PON6BlE FOReUBMETK OF DCINpABF#NG SYSTEMFOR L� y to SHTXDMMOEANYD MOPBORAO.ffi7IDNOFN 198441)1.TBIT. ER1HE HHOURS.TJRNNIHISTIME,h6COHTACTOR3HML1 FULYNBiRUCTh WNE EO31 APPROWALSYL0GALAUMORT18. r ij 14911311010€ ATTERTOTHE ENGINEER FORAOMISON BEFOtEO1DEI10 ANY EQUIPMENT OR RFPiISEITATNEBN TIE WWPLETEOPERATON 40*81ME4T.AOM*I4TERANCE MATMW3 ORBEFOIEBTMTNOMIY 1131180 310314 01 10€EQIMPMEN/TN10 SYBTBAS. ARESIF0.OT NSYSIBM 900100 BELL®ro4.31.8 GAS FRI THE 19. 54.11€WOE CONECISro7HAT(F N40TH@i 144441 0010 P8743 OR EQUIPMENT EXNMBTOUCTAND-OFFVIOODPORTFEDOEFNMI)€VIBL OE �'A M. THIS CONTRACTOR SHALLGUAR NTEEALLWORK DOTE BY EI.IAGA►ST DEFECTS N GAS SOLE DSHUT-OFFVALVEN W8lFE3EiMNCi IH#APALVOE NAACE FIBD MEASUREMB4188HALLBEMADE TO MAKE COMECINOWORCCOME MATEMLS MOWORIOAN6F34 FORA PFAODOF ONEYF}44AFTEROAIEOF BENGSBNEBYTHEFRVIERHD 0.VALVE 8HWLBHUT-0R GASANO IS 1RLEAJ4D LEN UP WITH THE ITEM 19100011410131. ACCEPUNCEBYTHEOWNER THE EIARANTEESHALL1EPRESMED7O1HE EIFfARGAL7OTHEAPPUM4LEWHBN SIPPf IONSY87EMBACMATED ETA OWNER N WRNG ANDMW AND 4410111018 DEVELg74GWITIN THIS STATE PERIODSHIAU.E1111DTO THE FULLSATIBFACTION OF THE OWNER BYTHB 20. TOT EOD REIEN RONC8 E80SAEWTION ANB OPEPAI 014 N4 SYSTEM6AR7' CONTRACTORATNOADDITONALCOSTT0THEOWNER II roTHEQOMPIETEa1PRTgiNSTALIAT10 MID 18181 IOfJa:ANYS08PO SHALL BE AIOVOEDBYTHE CONTRACTOR FOR SUCH SYSTEM WHETHERORR NOT 40. THE ONE•YEM GUARNTEE FORITEMS OF EQUPMENT THAT THE OYINER ELECTSro TARE 9PE(XPIOV..LY CALLS FOR BI IHEBPETFX.A710N8(IR ORAINOa BEGIN U SNG FOR NS SENE RTBEFORETHECOWPIE110N OF TE 4011 110901 21. l'NIEFTNIY CFEMMDCOTONAIE7HE LOCATION NCLEVaOFALL PPEa OHWL BEDIiATTHEDATEOF'BENSFIC L16F BYIHEOANEL 1HBOAIEOF 0.018.ETC.RNP11.1*I YLEVEISMOQE0(WITH 4LOTEROON•FNCTORS 'BENEAd11L USE•sFW.L BE 1814541140J01 1141 BF TFE 0494 i,41911101. 80THATOTRJLTS N ALLLCCAIIONB MAY IEAVMM. TIB OONTRACTOR•AtOT)EONNER TIE 10IT ACTOR8HAILPNFPMEALETTE R $TATNG THATTHEOWNER WE REOUFSTE'BB4EATAI.UE'.THIS LETTERSHHALL ry 22. ALL MATBWS SHALL BE NEWNOOF TE 0IJA TYSPECFM APPARATUSMO BE3ONEDBYTECXVNBWINSCONTPACTOR NOTHEARC:ITECT. MA7EPJAL.1910 44 TIBWORKVO4CHIMEBUBJ01104 PRO#*.BY 41. TIE ONREA.NOIDEtIOMWTMITHEINDOORMOUJYBYFOR7HB FACt1TYN U4DBIVRIE S U.)BRILL BEA RTHE UNDE WRIBB IABELOFAPPROVK CDWPUAN(EWTH EJ.W90OODEB,940UD PROVOEACONINAIO MMNTE4MCE 2& MW.FACT(RERS TRADE NNAE80R CATALOG NA.BES IBM N THESE PROGRAM FOR THE IFATIR VE4RATNGANDM CONDITIONO 04.VAC.)SYSTEMS. Jb ePECFKYOIQ6 MID 11010A180 010 TIE ORAWIKBAAE 110110 BE CClIHIOB�AB THE HVAQ SYSTEMS FORTIS FMRITY WEREDESIGNE TO MEETOR EXCEEDTHE RO PPfETAR POS Y.TEN PU E B ro DEN PE,OTE TY 804QUAIT A D M IY, DESIGN OF NDOOR 41J17 RET11gE,B4T8 aFANRAE5RISB0. EQUIPWE T. a• 42 SHOULD SPACE 1SAM OR OTx1PMNCYGANC#N IHEFunJRF ITBTHE OWENS • • { 24. WHEEEQUPNEMBSPEC♦AEAS*ORBXJ*1,RSHALLMMEOLMLAS REBP0K*B&RYWMMITMNCOWPWVOEWTHAPP FVBTMIONMOAR APPRIOVED BY THE ENGINEER INDOORM QUALITY STANDARDS. 31, TE 001414440108 8*FREE ro OFFER FOR CONSDERTION SUBSTRTE"EMS OF 48. Gib PPE BHALLBE SCHMUE 40 BlACHK 8111.UOERORTIOGAS PPESHA. EQIIVALENTIYPE.HIGE,OOATY,AND PEFORAN(EAFTERTE CONIRCTS BECOATEANDWRAPPM.PRO4OECATIOTCPROTECTION AS REQUIRE.048 1118 a n 8DIIMHONEVBR.PESIWLBEPFEPMEDTO 1111854 3880119 MATEWBMC NOONCFNID8PATS.11140115 01P11.11$144IL31WiOPWE SO IPWEMVWERESUBSTIMIONS ARE 111.0131 00 H60RGN4.8URITTAL FJOg*M TO PRE9K1iE/MM1 AR 8EW1 BE*11410. 21L STOUTDANYPARTOFTEMANGORSPE00OATIT613EFOUOTOBEN ppD 84.849431'ON8F4EEfT1(TIRE814EEi)FORALLAPPLICAE.ECODER 9) 1034 TWITHAPPLICA&EKp09ORCR0IUNCEB THECONTRACTOR%W.LNOIFY 44. AHED FAIG/JE81 PILLOR 105188411140 H1 10 48. MINT SATE OE1EC(ORB N SLIPLYMAMFERIRIM DI.101W0K 1O8HUT 21. 1H46CONTFWL'M W*I L RIME MRLCAION TOME LDCJILBU01C COOS DOWN FMB N M CONDTONING EQUIPMENT UITS UPON OETECMON OG SMOKE BfdRCB.BTOFACW8TOOSTMNALLNSPECTON PEFANMFETIED.MOSHWL t1.1801011 814411311018844110111I11 BE 04ZAIM TYPE DETECTOR N RETURNMTJCT SHALL BE RAYALLNECESSARYFE9 FORSA E HESHALATT)ECONCUSICNOFTE MOUNTED UPSTREAM FROM OUISDE CONNECTION.HVAQ CONTRACTOR SWILL MOUNT NSTALLAIION.BECLIEA80134CATEOF NSPECIION PROPERLYSINEDBI TE THE 33141800 1801011 NTHE0001WORK.THE ELECTRIC CT41RC1QRSHAL CONTROLLNOBUILDNGCODE EFORCEENTDB+MRME4T,WHICH SKALLSTATET4AT 11 11€TETECTORSAS REQUINC. 41.11131111(1(1*BEEN COMP4EDWITHANO 1HNT1HE WORK ESATBFACTORY.AT PROJEW C0.pLE11k ITN COMRAGTORSHWLSl9ATK9RIFCATEOF NBPECTION FORDEUVEFIYTOIHEOWHBLL t.L A• �e•(,, 31 THEORAWIGS FOR THE WORK 479*1)8 ONINONOF THE SPECFICATONS AM*4189*488043140*8.1. H,VCENg4. `Yjy THE7HE WO 1.T7 NMTBHOP ORAVINGS.NO"FI"NOTOT BE 1940485104 f*• Ne.85798 • STATE(F 4y 1ST t Dena emm MNEdt M5 1 PVC SPACERS 1381/8 (10)3/8" A.FASTENER W/BLOCKING(AS REQ'D) 6" 3" SEE CHART FOR ANCHORS BY WALL TYPE 30 1/2" 106" USE PVC SLEEVES AT COMPRESSIBLE WALL FINISH IF REQ'D) SEAL ALL PENETRATIONS! 28 1/g, • 102 7/8" PLASTIC TRIM CAP W/SCREW RACEWAY SERVICE COVER LED MODULE CONDUIT TO REMOTE POWER SOURCE (INSTALLER TO PROVIDE UL LISTED CONDUIT&FITTINGS,AND I v MOUNTING HARDWARE) n N Q r (2)7/8" ELECTRICAL ROUTE HOLE RACEWAY DISCONNECT SWITCH POWER SUPPLY MOUNTED INSIDE RACEWAY { WEEP HOLES IN FRONT VIEW (w/FACES) BOTTOM OF RACEWAY SCALE 1:16 NOTE:WALL STRUCTURE VARIES PER SITE. IT IS THE INSTALLERS RESPONSIBILITY TO IDENTIFY CONDITIONS AND ADAPT TO THESE VARIATIONS AS NEEDED A SIGN FACE ACEWAY MODULE(TYP) 7/16"DIA.MOUNT HOLE 7/8"DIA.ELECTRICAL INLET(TYP.) BACKER WEEP HOLES IN RACEWAY(TYP.) I� ® ® ® ES I ! WALL FRAMING• • ® ® C+ ®®p® O (T.B.D.BY INSTALLER) O O • •H ® ® ELECTRICAL NPUT SPECS. lED C (3)POWER SUPPLY • • ® ® 8434 TOTAL 27 AM S EACH(EACH @ 100-27 USE(1)20 AMP CIRCUIT WALL SECTION"A-A" WEEP HOLES BACKER SCALE 1:8 17, 26"RACEWAY • 88"RACEWAY GENERAL NOTES FRONT VIEW (w/o FACES) SIGN TO BE CONSTRUCTED TO 2014 NEC 600 STANDARD INSTALLER TO PROVIDE COMPLETION PHOTOS OF MOUNTING/CONNECTION POINTS,WIRE ROUTING SCALE 1:16 AND OVERALL ELEVATION. SIGN TO BEAR UL LABEL THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE NTH THE REQUIREMENTS OF ARTICLE 600 SIGN MOUNTING HEIGHT TO BE 30FT MAXIMUM SIGN TO HAVE ELECTRICAL DISCONNECT ON THE EXTERIOR OF THE NATIONAL ELECTRIC CODE AND/OR OTHER APPLICABLE LOCAL CODES.THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. ANCHOR TO BE THRU BOLTS IF POSSIBLE,ALTERNATE ANCHORS PER WALL TYPE SHOWN BELOW FOR USE IF THRU BOLTING IS NOT POSSIBLE FLORIDA BUILDING CODE INSTALLER TO VERIFY SIGN IS PROPERLY INSTALLED,CONNECTED AND GROUNDED. THIS DRAWING IS FOR INSTALLATION PURPOSES ONLY AND NOT TO BE USED FOR MANUFACTURING. ANCHOR SCHEDULE: 3/8"DIA.ANCHORS 6TH EDITION(2017) INSTALLATION INSTRUCTIONS QUANTITY: (4)FOR RACEWAY IN PAIRS @ 48'OC,(4)FOR LOGO SECTION 16 WIND LOAD Q• 1. OPEN PACKAGING CAREFULLY AND INSPECT FOR DAMAGE.IF DAMAGE IS FOUND,CLAIM MUST ASCE 7-10 Q LICENSE BE FILED WITHIN 5-DAYS WITH SHIPPING AGENT. WALL STRUCTLRE ANCHOR TYPE ��� 150 MPH WIND LOAD 2. DETERMINE SIGN LOCATION AND TAPE UP THE PROVIDED TEMPLATE ON THE SURFACE TO WHICH WOOD BLOCKING LAG BOLT(3'EMBEDMENT)THRU BLOCKING IT WILL BE INSTALLED,RECEIVE CONFIRMATION FROM CLIENT OR CONTRACTOR. RISK CATEGORY II 3. LAYOUT AND PRE-DRILL ALL MOUNTING AND ELECTRICAL HOLES REQUIRED FOR MOUNTING THE EIFS OVER 518"PLYWOOD UBERTYTOGGLE BOLT OR THRU BOLT WITH SLEEVE EXPOSURE C LETTER CLOUDS TO THE WALL. HOLLOW CONCRETE BWCK BRICK SLEEVE ANCHOR(1-1/2'EMBEDMENT) 4. FILL ALL HOLES WITH SILICONE PRIOR TO MOUNTING THE LETTER CLOUD. STATE OF 5. ALIGN LETTERS TO MATCHING PRE-DRILLED HOLES WHILE INSERTING FASTENERS THROUGH LETTER SOLID CONCRETE WEDGE ANCHOR(2-112'EMBEDMENT) O CLOUD,WALL AND BLOCKING(AS REQ'D).FASTEN WITH HARDWARE.USE PVC SLEEVES TO CMU,SOLID CONCRETE,BRICK HILTI HITRODWIHY-2T)ADHESIVE(3'6'EMBEDIHT) ENCON SERVICES, INC. PROTECT BUILDING FINISH SYSTEM OVER SHEATHING(IF REQ'D).6. MAKE FINAL ELECTRICAL HOOK UP TO PRIMARY WIRING OF POWER SUPPLIES THROUGH DRILLED ® P.O.BOX 3613 SS ELECTRICAL HOLES. APOLLO BEACH,FL 33572 7. TEST LIGHT FOR PROPER FUNCTION AND ILLUMINATION. ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE ® 813-655-3373,FLEB#9394 AARON BIEDENBACH, PE 52949 8. PERFORM TOUCH-UP AS REQUIRED WITH MANUFACTUR€RS INSTALLATION INSTRUCTIONS 9. CLEAN INSTALLATION WORK SITE OF ALL EXCESS MATERIALS AND DEBRIS.DO NOT DISCARD ANY ENCON@ME.COM �+ MATERIAL OR DEBRIS INTO ON SITE DUMPSTERS. DATE SIGNED: 12/20/2018 INSTALLATION DRAWNBY CJB SITE TITLFpIZZA HUT 21" LED LETTER & LOGO ON RCWY • 8S a PIZZA HUT (NPC) Erbrffe DRAWING DATE 03-26-18 HALO w/ BACKER •oo OO 4949 SO.I IOTH ST. 5897 GALL BOULEVARD THESE DRAWINGS ARE THE IXCLUSIVE CHECKED BY PROJECT NO. DRAWING NO. RIV •°O O°• GRE NFIEP.O.BOX�I 53220 PROPERTY OF EVERBRITE,LLC.USE OF,OR RHB ZEPHYRHILLS, FL 33542 74 7 o 00 4a 414529-3500 DUPLICATION IN ANY MANNER WITHOUT 379766 I N / I / B A •q ® EXPRESS WRITTEN PERMISSION OF EVERBRITE, A 3i8 CJB RHB RELEASED FOR INSTALLATION DATE 03-26-18 SCALE AS SHOWN REF LLC IS STRICTLY PROHIBITED. REV DATE BY CHK DESCRIPTION UN TAG FAN UNIT MODEL N CFM ESP. RPM H.P. B.H.P. VOLT .P. 0 VT FL saNESA DISCHARGE WEIGHT FAN23' n VELOCITY (LOS.) 23' n 1 OVEN DIA35HFA 1210 1.590 1352 0.730 0.4890 1 115 8.8 383 FPM 97 15.5 n 2 FRYERJ DU33FR'A 600 0.850 1439 0.333 0.2030 1 115 4.4 297 FPM 74 ]09 FAN*1 OIRwTA-FI()ALHST FAN mVDD FEATURES, VENTED ClIlRB 'WA FAN INFORMATION — Job 3447095 -DIRECT DRIVE CON6TRUCT100 em BELTS/PU.LEYS) I SAN MIN DESIGN WEIGHT --m 7/B -ROOF MOUNTED FANS 20' UNIT TAG FAN UNIT MODEL M BLOWER HWSITG GFM CFM ESP. RPM H.P. B3NP. s VOLT FLA SONES -1LM ANND IIOOEL MR]. kF -UL701 Alm UL768 AND ULC-56413 AI-G10 G10D Al 0 930 0.300 832 ( 0 04400 I 115 (OR I% 16.8Iø -VARIABLE SPEED CONTROL 20GA10E "I'll E Z INTEONAL WRING CONSTRUCTION 8 S STEEL -WEATNE1iPR00F DISFLLVIECT FAN -THERMAL OVERLOAD PROTECTION(SIMIB.E PHASE) UNIT TAG OPTION(Qty,-Descr.l -HIGH NEAT OPERATOR 3007(149.0 /' 3'FLANGE GREASE CLASSIFICATION TESTING / ''I''' S I-Grease Box 30 1/2 NneHAH TEMHERALL ttST ''' I OVEN t-Wrpe Kit- Ships Loose for Curb Suppled by Others EXHAUST FAN NUST OVERATE CONTINUOUSLY ROOF OPENING '1 ' I-ECH Pack Exhaust-PWM S fro,,ECPM03 Preelre(NII(C Motor) WHILE EL FAATING AIR AT REA 049'0 22 1/2 DIMENSIONS � Virkp nge- 18na1 ONitL ALL FA(PMTS HAVE READIED / I-Grease Box THERMAL EQUILIBRIUM,AND WITHOUT ANT 22 I/2 J III' 2 FRYER 1- Hoge Kit-Ships Loose for Curb Supplied by Others DETERIGRATING EFFECTS TO THE FAN WHICH 1-ECM VIrIrHg Package-Exhaust-PVM Slgnst Pro..ECPM03 PreXIre(NIDEC Motor) GREASE DRAIN WOAD CAKE LMSAFE OPERATION 1' 3 1-ECM VA-log Package-Supply-PVM Slgrwl iron ECPlg3 Preeire(NIDEC Motor) }_ • lAl. i.w--i TroT PITCHED CURBS ARE AVAILABLE 0' I 2 £0104011 FAN lBRT OPERATE EDITH WSLY FOR PITCHED RCS. .^e eros14]JB WHOLE EXHAUSTING BWMING GREASE VAMHS 0' AT 60VF(316'C)FOR A PERIOD OF SPECIFY PITCH, EXHAUST SUPPLY I 15 MINUTES WITHOUT THE FAN SEC04M EXAMPLE 7/12 PITCH=30'SLOPE FAN 1 DAMAGED TO ANY EXTENT THAT COULD CAUSE • UNIT TAG - -- AN UNSAFE CONDITION }➢ 1 0411 GREASE GRAVITY WALL SIDE GRAVITY MOT13RIZED WALL ➢V87/ CLP HAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT 2e Ire �71mS 2 �RYER YES e4 y4 HINGE KIT-SNIPS LOOSE FOR CAR /\ /� ECKSIP WIRDING BY OTHERS .V/ SIG VRDIO PACKAGE-EXHAUST-PAN DEC ,, iDTOR FROM ECPIW PRCWIRE M[OEC +� ROTOR) NO. TAG WEIGHT ITEM SIZE Dl1CTVORK BETWEEN Mi1MB110W FAN EXHAUST RISER H,1 HOOD AND FAN(BY OTHERS) 1 M t E56370014 32 LBS Curb 23.W0'W x 23.000'L x 20.000'H Vented ,, ]BODW.t3BRRiIRBOT 2 I e 2i E56370026 I 30 LBS I Clrb 19.5W'V x 19.500'L x 22.000', Vented 011BIENO PAID(.KAlISAI 3 M 3 29 LBS Curb 2L000'W x 21.000'L x 20.000'N (ae MMOE'PRO EB]4m *0115 FAN 63 A-GIOD-SUPPLY FAN . PAIL•PIB)0B)1I I.DIRECT DRIVE DIRECT NAIVE IMTEMERED SUPPLY WIT WITH II'BLOWER IN SIZE 61 HOUSING WITH SPEED CONTROL. DISCOMECT SWITCH 2.INTAKE 41000 WITH EZ FILTERS-LOW CFM 19 1/2' T 4.CC IISCHARGE-PACKAGE SUPPLY HOTAIR FLOW RIQIT S WITH►IOM SIONL FROM ECP O3 PREWOE. FAIR - xuumT FAg MOTE'SUPPLY DUCT MUST BE INSTALLED TO MEET SNACNA STANDARDS.A MINDSM STRAIGHT DUCT LENGTH MUST BE MAIMTADE9 ' ➢OVNSTREAH O'DDT DISCHARGE 1MLES5 OTHERWISE SPECIFIED.W MOT RELY ON DOT TO SIPPORT MET IN NIT WAY, FEATURES, ^ C TED FAILINGOPS FT ED SISE DUCIZETWORK • RA U�EBSYSL EFFECTS AMR REDUCE PERFUNWAICE OF THE EQUIPMENT. DIRECT DRIVE CONSTRUCTION(MO BELTS/PUIEYS) 21 1/2 -'{ -ROOF MOANED FANS 22' GLOVER DISCHARGE -RESTARMT DWG. CURB M -ULM AND ULM AND U.C-56'/5 20 GAUGE -VARIABLE SPEED CONTROL STEEL I` -INTERNAL WIRING CONSTRUCTION 13/4' -WEATHERPROOF DISCONNECT -THERMAL OVERLOAD PROTECTION KSDGLE PHASE) WHOM NEAT OPERATION 3 F(N9'C) FLANGE GREASE CLASSIFICATION TESTING 25 1/4 FlEBAt1NEt f- 1B 1/2 EXHAUST FAN MUST OPERATE_NTIMOUSLY / ROW�ENING 111 cIII V)11 13 l/4' WHILE EXHAUSTING AR AT 30'F 149'C) ` DIMENSIONS 1ANIL ALL FAR PARTS HAVE REACHED I9 �., / 19 L THERMAL EQURIBRRM,AND WITHOUT ANY �/ 3 7/B' DETERIORATING EFFECTS TO THE FAN WHICH LH_ 4 GREASE BRAIN WOULD CAUSE UNSAFE OPERATION L *IRR L FLARE-1V TEST PITCHED CURBS ARE AVAILABLE II I/C Ji_ e EHWST FAN MART OPERATE CO TIN O)SLY FOR PITCHED ROOFS. U' WHILE CIQWKTIAB HUWDG OIEASE VNPDRS 0' FLEX CONDUIT AT 6007 Ut6'0 FOR A PERIOD OF SPECIFY FUR FIELD „E IS MINUTES HE WITHOUT T FAN BECOMING P DAMAG ED TO ANY EXTENT THAT 010-S CAUSE EXARXAML PITCH, IWI.E�7112 PITCH=30'SLOPE WIRING I._. AN UNSAFE CONDITION CS- 19 II I GREASE BOIL 22e��L NUPE SHI OR CU PS LOOSE FRB .� APPLIED BY 074105. .r El `. ECM WIRING PACKAZ-EXIMiKT-PVM (n bT StGRNM.FROM£04103 PREVIRE fMIOE[ -..� DUCTWORK BETWEEN �W). OB' •\ EXHAUST RISER ON HOOD J LL AND FAN(BY OTHERS) e7 3/8' 32 I/O" (.Y W ? E�fs LIFTING LUG ° N W AIRFLOW N 3 rSC CT AIRFLOW e9 3/4' SWITCH• OA7fB 6/18/2018 ACCESS• / � oe 24'SERVICE 3447095 3 3/4• DftA-T- DJL-45 161/4" MINIMUM 3/4" a 1_0= s, MA FOR ea•EQUIPMENT CURB REFERENCE �--0 DIET ONLY RWF OPENING 2'SMALLER THAN CURD DRPNSIW L1I. *W N . YIHi 2 [ M7 ] p i FAD MAX.1Q INFORMATION -_Jab1447O95 I __I EXHAUST ) TOTAL I,mDIWOCFffi NO TAG MODEL LENGTH C KlAG TOTAL SUPPLY CdiSHOOCTION END TO ROW TEMP. EXH.CFN WIDTH LEND. IGHT DIAL CFN VEL S.P. CFM END L53 SERIES E24 CANOPY LIGHT FIXTURE- HIGH TEMP AS$IT Y,NCLLmCI CLEAR THERMAL I ES637010./+(56370107 7230 11'0' 450 lab 0 II' it, 4' 1210 1440 -1.072' 930 430 SS ALONE ALONE AND SHOCK RESISTANT G.OEE ft55 FIXTURE) CND-2-252-F DeD Where Exposed ♦♦♦:��♦�AAlA�lll� 25 I 2 (56370105*(56370106 042 4'0' Deg, 600 7' 7' 4' 600 1763 -0293' 0 Whet.I 450 Exposed ALONE A C7 .fr / IIN OF WOO7MEETT$0�n211 Y MS7ALLED II REQUINEM 015 FOR CLEARA NE TO COMBUSTIBLE I TAG EFFICIENCY E 7 V[RE SYSiE SID 3r .D TYPE TY HEIGHT LENGTH TY TYPE L(SATIOM SIZE roan WRAPPER 2600'N1GN i MICRONS TYPE SIZE MODEL N QUANTITY PIPING WONT fSEE HImD OPTIONS TAME) �Sf 769 EXIYIUS1 RISER Nom. 1 (56370104*(56370107 Pizzo Oven HVC Filters 4 20 16' 4 L55 Series E26 NO YES LBS iI!!i:' 2 (56370105+(56370106 SS Baffle eith HAMDes 2 16' 20• 3OX 2 L55 Series E26 PO YES LBSHaRIiONTN. '' O r WRAPPER HANDLE OPTIONS I'LAYER OF EMULATIN FACTORY 16'SS BAFFLE VITA '' ''' a#�TAG OPTION W TALLED IN RACK REQUIREMENTS FOR I'LAYER!t INSU.ATIM FACTORY 14'NON 'If BACKSPLASH 111,00' High X 132.00' Long 430 SS Vertical CLEARANCE TO CONDu5TIDLE SURFACES. INSTALLED IN r 1NTERNAL STANBOFF. LEFT QUARTER END PANEL 23' Top Width, 0' Botto_Width, 23' High 430 SS CLEARNEETSICC TO NCH REX PIENCRLE FT s RIGHT QUARTER END PANEL 23' Top Width, O' Bottom Width, 23' H 430 SS 1 E56370I04+E56370107 INSULATION FOR TIP OF HOOD IT IS THE NESP/OWNER TO INSULATION FOR BACK OF H000 r OF TIE AROIITECTlpVHER TO 47' III FINISHED BACK-ISL/REV INSTALL 132.00' Long,(Filters to the front) T— ENSURE F10!THATT THRr B)S1€IWI �IITIBL[ 0tl. RISER SENSOR INSTALL 6M PLEN 7• AND COMMUSTIM.E MATERIALS IS INCOX RWNRE VITA 47,0'MAX FIELD WRAPPER 26,00' High Front,Left,Right 'r—I LOCAL CODE I.IN t VITA TA BACKSPLASH 111,00' I4gh X 8420' Long 430 SS Verticol �. "'I 7, RIGHT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 430 SS , X D4W Lpy111'�X7GH 2 E56370105*E56370106 LEFT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 430 SS UL.Listed L55 Series EN% fRIEASE➢RAIN i FINNCHYK Light Floture-MOh Tero M y li INSULATION FOR TIP OF HOOD (1 � WITH REMOVABLE,CUP ERSEINSULATION FOR BACK O6 HOtLI FIELD INSTALLED RISER SENSOR INSTALL 6M PLEA OIAT FIE END PNEES E4' RISERS) I HOOD, FORA7'ED SUPPLY EOUIPNENT 7SO0w.1TgMS1 TTAG PUS. LENGTH WIDTH HEIGHT TYPENKI. WIDTHLEND. D1A CFM S.P. 24 BY OTHERS ,fOAO6AH ►AM.RANBMMl1A 6' 1 463 0.141' 0@13MI016IR1iR3710RRB 1 (56370104*(56370307 Front 132' 9' 12' FAX:PI'8 RB7-01006' 2B' 465 0.141' 04 a 4'OAO'OD II PLAN VIEW — Hood Al2__(E56370105+(56370106) , 4'000 LOG 334780-2 11 - - - HOOD_-_*_rsss7 TE SERIES LY.CANOPY LIGHT 14200. MGH AND 64 AX RESIS DCLUOES CLEAN THERMAL NOTE' SHOCK RESISTANT CLOVE ass FIXTURE) ■R PE I HOOD�MFED FOR MSUL 8402 P LAYER 0'INSULATION FACTORY INSTALLED J LL W TOP Of HOOD.1221$0 14211RE5U�TS FOR CLEARANCE TO COMBUSTIBLE ^�e0B0 J 7D 00 10)1 V S AU WM SHALL COMPLY W1I _HNXDNG ANGLE /=-T U'VN-111'OAO'p0 PIFFACODES�STAND423.5%O VVN UME 04414(11 /IGOPLY STEEL PERFORATED PANEL 2 3� L` A L x NOL .... p����� ap N ze' B1GriG1T IT IS TIE RE T/DVN R TO v'VITA ___ L _p Q ff TAT TRCIHTEC7lLEAR CE IIj �������. e WEtWNE T1MT TIE IOOD CLEMANCE = FROM LIMITED•COIUUSTIB.E 0040■Of�R /�G 05 114 N LINNCE V[iN L) _f CODE HEOUNElENTA !L P3• - Z z -1-` Q Q GREASE DRAM _ ?— ;;r VI7H REMWABE CUP4&0,MAX IUL. <ed LSI Ser4e(706 Ce^ePYNI N LJ..ILipht Fixtw- T IN. erq MserMy li!' LEl'T AND RIGHT aNAR7ER END PAIELs Q. N RACA(SPLASH ILLW HIGH 0132 LONG B er YATfF 6/18/2018 DVAJI 3447095 s Ire EYOTicRs W s�'1�S r 3/4" - 1,-0" FOR F--- REFERENCE ONLY SEC _ _ — — SHUT NO. IIII�iONllOflt HOOD_—_*1_(E5637OIO4+E5. R7O1O7) 1 if M6 { { a /1E ASFOOMETO7HE WMX°'°4� ` 1 ARC?RECf18Y M LORNNNGCri"KSHOULONOTS(CE®TWORI VWX.OfYTH(MN R1DRJS4GOEGgM7LMMMD1EN(10)FEETN LENGTHCOWA LT 39.N 1DN01TUDRML I.NSf�VBYNAQ10N 8YSIBAWLLBE BY CONTiAC10R 04WST FACTOR SIDU 411SOX 4179 FOR DUGTWOAK THAT EXCEEDS OVENAPAT COLARSWILLBE PROVI ED BY CONTRACTOR HOODS DOLL SENSYALLmN SAfNETJONf ACCOFD.ANCEWIM NFPAA NDALL O7HE R APPLICABLE LOCAL,STATEN® LOJIS-NMI FAG4�LiEMUST BENODFW FOR S(IEADMPfAIM NNIUNAL 000F8.SPEQM.ATFENTION MUSTSECA81 T0000ES REGNOIING .POSITIONTHE FABNGTEDDUCIVVORX TO MATCH THE OIYETLO(YOICN huh CLEARANCE70ffi1RRDUIDNGCOMBUSIBLEMOLMT®0(11BlBiIBIE SACOHItA101BOOD.TH DUCrMDTr BE 39 AT XIWNBRION AfD TMEiPHi.E1131 (NFPA9B OON6rRLO110N lWALLB•C99NGa Ero} 2 CONTRACTORS F�PONSSLE FOR DFKUNG RETAtN680LTMOM NTOWALL DUCMWAYLAffTMYANDALLCODE REOLIRBMBM OVERLAPAT ATTOAANDBOTTOA OF HOODADPRWICING THE B.CONNECT THE DUCTWORK TO THE CURB TRM6RgN TBMA7NGAT BLAM(ETJONT 1FE TOP OFTHE YOMCU B EnENMONSBOWTHE FAN BASE DO 1W0 LAYBffi 1-1rPhq( a CEIL9q ENCLOBUE RJNISHED EIY HOOD M NUFACTU ER WLL BEATIACHED NOTTEIMATE RE DUMWORKATTHE ROOF JW DUCRMON(MUST FNBMBIERBLNITFOR MN ONE NTHEFELDBYCONIMCR7R BEW(3DED WITHAC0NRMOUS LDUDIUHOWELDATEXHASTFAN 1-7? HOURPRIERA1NG(STAGGERJCNB 4.DUCIWON(BE1WEENNOOD MDROOFTOPQ/61RVAIIIIONYYBLBE CRB1RANBIIION. 10.12 /TBETWEENJONTS) PRDIS®BYCONIRACIOR 7.ATTACH FACT SJP ORYPLIED NGE KR RD MD GRF4SEIJGHTO FAN (n CUB PE RNFPAISa M. J a ENCLOSE DUCT AS EDUREDOf LOCAL.STATEANNATIOALFIRE HoaD PROTECTION AD MECHANICAL CODES OBSENNON PATKXAAR THE HOW j C EN1ANCET0001B116T6lERKNSIDF4 i 1�APi SA L BLEPoRMFROPMFUNCTIONOFTHESYSTBACALIBED II 0.OCNIECTMO TEST THE HOODS WE SUPPRESSION SYSTEM.ONLY r 211V i BY CHANGES N THE SY3IBM STATC PRESSU/EOR OVER ALLNRROWVOLUME PROF�91diMLYOIWYEDPERBCFMSHOUDPELEC(NTH E 1M2' VELOCITY MNSTBE BEIW�419X1 AND 2MO FPMMBWHWELDED DUCT. FACTON(S1PR�SHROID 10. lOQ£IX @BIAS PROPER PLACEMENT OF THE GREASE FLTEJLR AHD NOTE: 2.BOWSTAIR FLOW MIST BE BALANCED WIIHOTHER ExFWSTA MAK6UPM SHIPPED LOOSE:ATTACHED BY GRFASEQF. 1, WRAP GREASE DUCTCONTNUOLS AS SHOWN BELOW FOR B41 LENGTH O SYSTEM AND THESTORE FNAD SYSTEMS UPONFBNJATIOL TESST&EAACE CONTACTOR 11.FBAOJE THE PRDIECINE PVC COATNG FROMALLOF THE METAL FROM KRGEN HOODOONECTIONTO EXHAUST FN ON ROOF. STMFEW NSMDYOFTHERWAUMOONiMCfCRFANOPEPATM FIBD DRLL FOR SURFACES PRIOR70 USE OF THE APPLIANCES. 2 RATING REOUIRBABAB:tSEs OSTPNLFSSSTEEO.FORMN ONE HIOIIR SPffD,BELTS AND PUUlEY88HOUD BERECE(:KEDAFTER 00 DAYS TO ENSURE M0LAVTNGIO 12 RUNCECK THE BNALWT FAN AND.FRYERNTERLOCK, MTNG > Ni0F6tPEFFCR AMSTATICP VALUES ARE Oo9N FOR THE HOOD S(RUCIIIFE Ia CERRT®TESTSBN/INDE CONTACTOR MJSTTAKEFPM HEADINGS a WTAPSRFORTFETHREA STBMITIONS NiLYWITH BAMETHI70E88 ONLYMO DO NOTNCLDE DUCTWON(MIDROOFTOPFANa ACROSS I/E PLLT6T BANKND CONFBM THAT SOVVST FANS FOREXTBd1At FaEMEATCON011ONS. 3.AIR FLOWS ARE NOTED N MIEO*4C4LSCF�UE CPSAINGATORABOVE THE SOiNST CFM1 DESiW4 POFNf.MNYAIR L OAPINEAIER THE ROWTO CHANGESPERIG(TIONS 10 TOODE FLONIEVEL 80.05 OPC5OTS NDTAOCEFTA&ED0 NOT NOT USED NT 18 oRJa1HEOL�HB>aNTs. 1a LEVEL& NCTHaNAL N3 ecrloNBAB�awED.FORFaT�AaFLaw HOOD EXHAUST DUCT SYSTEM DETAIL N.- 13 Io APPLY FABNCA1ED TFIl M(CONTRACTOR SUPPLED)10 148 CEM94GAND UL LISTED GLOBE LIGHTS soaps RFOLIFIEDFOCTORYSOR&IIE 1. 80x1 BE FASiCA1®N ACCORDANCE WITH NFPA BULETNNW6AND PANELS)FROM TOP OF HOOD TOCBEBU SCUD BESCREWW1O SO4RLL BEAR HE NSF SEAL OF FOR O OP VAL HOODS AL EM�FIEI IL -E AT TOP EDGE OF HOOD WITH 83RTAPPFD88 SCREWS. FRYBRFN000 EJGNALIBT FMI 14 OE NI THES RFACES OF TIE HOOD WITH AMID LET ERGENTUSI NG1 91 K"a4m ONE NOT ro&IRATC H ORDENTTHE SU FACE 17.CONTRICTORFM+ON98LE FOR 1al 1P10 FROW FROM MAC OSCHAROE tIBOF1T FSEEXIINIGUISlNG IBYSTEM DFFUSERS+MRN G FEET OF PRIER HOOD AWAYFROM HOODAND 1.FADTI MF6TALIID FiE SLRNGtJSFMO 9Y81E1PIPFO8i1PR!®IVD SKNFED ENDS WITH COVER 0904ARGEWITH PBEORATED PANEL NBTMIBINACOimmit E�WRNNHING.B YFaES DAND 81 FINISH ON BOTH 1a CONR4CTOR RESPONSIBLE FOR RLDFECRM3(NAC RERUNS BERN TENANT CSCCHIECT FACTOR/ 2 CAUTIOR FIRE S0►GUISHNGSYSTEM INSTALLED ON SIM MST BE DOWIN OUiERNONI$i 10.FEETOF ROM HOOD AWAY FOM HOOD WEEO NEC THROUGH 11 A RNCEINM AVIEC ro 80 THAT PIPE DOES NOTNIHEEREWITH 19.CONTRACTOR RESPONSIBLE FOR STORE TESTA BALANCE OF HVACMO DSCOINECf1HeOUGHTHE (000 PBibRM1ANCE WPROPBi FSTALUITON iMY W W UL LS11NCi ALLKIIGEN$64MJBTMOSUPPL CHED Nx.OFONG TO hE 9EA71ER YUBE II MSSMCHEN S'"T NCISUE80i®lAE ' YYrnatloHW 1 FNI CONIR018(EG.OWtlFFSMTOS.TH871NLOMRLOADPROTEC1IONMD LIOlAD1KiHTFIFJGSIECONDUT OVBLVOPNaLRNaAi MAW FOR FAN TORE FUN6HED BY OTFEFS. 2 ANSU..FAN AND FRYER IN MOCK SHALL BE YYN®BYOTHEISAOOOROFD FF6PROOF XIBULA710N Amom.8713377#a TOSCHBNI•CRRNWHEDVAHARCHnEMPAL DRAMMKS. REMOVABLE - VENTEDCURBIXIBISON PAX:a»A aIIwN FIELDOFILFOR BOTTOM SUE �H MOUNTNGTO SKpT8 MN 18 GA WELDED SGwlBT YJBEIALNSMLLAARKTH 6: STR ROOFSURFALE _ OCT.SC1B10 MIL OF 1E 1. ANDFER FBMPLA DOR THEDIEOFTHE IOCOON THE WALL IRE ro THEAaCNTWTB RAN FOR THE DIe+eHON)tHE ABOVE ROOF DECK PER PA TE SA ROOF DEC( 2 .&WALL.MOUNTING RANGES AT70PM08OTTOM OF WOOD TOA GREASE TRAP MNI MUM OFTWO(2)OR MOTE WALL STUDS. a ALA.MOUONGMND'ORBRAOWSWICOMELYWRHS98MCIDNE3 f Q NOT USED N.T.a 12 HOOD NOTES 017.8. 10 EXHAUST FAN NT.a 9 A i JmJJ J� _t9 I � JOSTW�A6dBBR rxoFPANLa 1N•MIX. tN'MAx i PoaNr 1 BTBD NNGIE BE,WEEN LOCK TYPE WASl1ER JOISTS,a MAX At- 8180.RATE (OF PANEL. —�— WASIBR ONNHL PONE____ \PA a0.OR BB UI-L L2-lMxi 1a><WIB J-- SURgRTSTRL1CTURAL iN ROD HANGERS®N NOTED: STEEL MEMBER 1 BOTTOM(%TORO 37L TYPE i R00F.E HUIDOF AB RECOM�O®BY NMN F.OFROOFJOBT M1f9WA1HERL RDOFJOBT of EOLMP.SIIRPLJRIBY.AS Roo HAN(EFI 1059001101418 97b.TYPE 3 NUT BESLPPOR EOQ Y�iMaFRBA ro I�rMFt �a MOLE 90809080I HhI i HANDER 1 0508 LEN THAW 80 POUNDS NOT USED Nrs 8 NOT USED Nlrs 7 EQUIPMENT SUPPORT FROM BAR JOIST* I N.ra. 8 SCHEMATIC ROD HANGER ATTACHMENT N.r.B 5 JOBrw®MEMIBFR fi PAEL g POW 31 31N' ' JOSTa EMAIL MAK RIE TOED OUr"AIR NTAE HIOOD A81M325.1YPE3 LSX3X3i8 • 8� PEALOAD9D RiTWASFER PNB 1N 1N OREOULL NUTM325.1YT'E3 ROOFTOP �� C3A4.1 MEASPBRLOADNG OSOER C� O0N0° TED - IMPORTANT NOTE: VV A. ALL SUPPORTS 81/OR BRACING OF EQUIPMENT,CEILING �AcrJv� OF ROOF JOIST 1e• 9r BOTTOM CHORD OF ROOF O GO,LIGHT FIXTURES,&ANY OTHER INSTALLED DEVICE ROD RDDHwN(ERROOF ( EXIBLE rP m ® FRAro(BDacoutnvLFu9HNG SHALT-BE COMPLIANTWTH LOCAL SEISMCZONE w INo.�es W v STATE OF ND REQUIREMENTS. �g W 114 0E NO EXCEPTHONSi e LSxsxaB EXISTING ROOF S � 1N Si16f MIII�[R R� C3XL1 95 &BO7HJJCIRI BUPPLYAIRDUCT BOTH ENDS OF CS a BOTH BOTT 10110 OM 0 018188P FOR0(010101ANN IX�CS�N M4 JOISTANG.ES OF ROOF JOST YQADC VOW THAN 2G0 POUNDS BU(I=III N400 P019DS NOT USED 011k 4 EQUIPMENT SUPPORT FROM BAR JOIST* 011.8 3 ROOFTOP UNIT Kra 2 NOTES NT•a 1 TL 71 d30-3Ndl Iona HONVUS ONF681VOI NOM!!31 Nnd i3na lb'OIdAl E 1 TiVM a31V!!3»IdidON ndHl NOLLVli13N3d lOna f siN a3Sn iON Fiit EwI tt3MfwA�fa O m _ TW-r im • $ "dow°Driss \ / wetx�t-txvt-t iS' p d M 331T/Jfao dMLM1of10 �r3W �Mi !D/IYJS Nip ledWA 80NNNU03�HLNO • wcw of • w13a dVU19te8imf y, ta1�3eNaT 331 tea BVSM3d09 h `,� awm NrNa%=331 &A3MSw13W V 1 PIOIL ti ISNOLLVNNOe1 IOANH MSOMUO TWMmLVH NOILVV7&ITV39 1Drw f Wdoa va1°i 9 81N a3sn ION g 8LN NOLL03NNOO lOna a3JNtfld OLLVW3H0S s 8.1N MO813 SnIGVa•lVOIdAi c •1N 13siao aNV NOLLISIWH.L 10na 1Vow' R�� 1SV3001LI1S bL 3DVd LL39ld0 Silt"m Mt urn x6.O VNO MMS VNOVWB'mu tId 01 SNOUJ3S tiOILYYfBNltfod GA=H)Bf00dU TIM '9¢DU 33S U3000N13VNV'Id1Df10341 `MwmloftO.VlDYYUA 33S a u�� d098swo 7m3ulom '803dS338'l9/L9D019t10u038 tl "' M3W133t9dOGMe 3tu19Vd MLift93txx69 OU.4%/M Qi30e Tf"NOt YVMM MMVtNH.40936" NoutsrreMl NO0V1faA-4llllIIIJIIIIIIVIIIIIIIIllllll -N (ztN dk%ow Lan NIM133t9 t�t9VD i�,�f�i 3DR.'W NOU-'aNPD i= NO1Mt Af ,••.�j F3=H3WlVSLTOB M 8 9'L1 lOna a3N11 AIlVNa31NI 1V JNISON lVi3W Ot •CLN OUVW3HOS NOLLVTMISNI H3Nf1Iona 3181X314 iii LOna a3Nf1 ATIVNN3INI nHH1 NOLL03S 1V3IdkL LI a1N a3Sn iON S MVOLD3d9338 TN•3N63OMR" NotLVYM4 WNt 3 M (MV003901837m �, 36leNNUL lwa' a IVNmnilDNO't 'C}3d633e•erfdvN 3N93gV tWM1of1O01 tetft 3te1M]V l3WSV3M4D3WV938O1 SS301mu d k�t0�IOM �SfTd U031�D/NBON M.T '60346338 CtYi 339NOILVYt9i8 ��ld"(3OO 960Dt ATddf190H W4VMVx•7MdQWf%nD IHMSLNOfTivim 17flItf NlRt'M�L MOId tN '63i01.3lVStOLL:?JSJof10 N3HM11f1B TtMA93Dm 'OL3'StlW'61ed1'M7 d0 �• NOUVft9N 1VH13Uf198 'L'7f10 dD 3189 ND M91197N00'ADWHOW �13M tw" L,x%10W�H! �tJe only =v Notmasac1 wise Hon9'AIDo'eA $LgAtl'SM3AS/Mlofxt T1YffB NDLLV1f198MR01NIZ teW1L'7f1O dDNOLLO3B dOt Hili7lfVtM dD 883IMNOW Umod QLSMSOH71I HCIILV 3d41teN3L8Vd ONWdD39 NMLVYM TN1r0N90NTVt3w 3N83tfOV io%W&KMiiI D0 tfDlOMUNVISSludO tfOieOe l.OflO _ Of1O B-ESM338 VNOWMW 1V13N193H8 '7V1d3lVW 3HLO1 Q9FBFIOVt9I1 pN0Vd3t9elS/d tt0du tewtlO(lO ,t-Jy ilt70rd'Mi Mxt m9�UdYiD00tWmddt %rfN/i SMNKI Qs NOUof1ULSStDOtoM VIJ7*%339't I� s3LDN £l 9'1N NOLL`1flSNI)103N ONnO8 RUM 83Sn la AlddMS P11 1UOddns)IMOMLOna 3181X314 911 B1N t13Snilla JNni30 NhAVI ac •91N a3sn ION I mnmtfo9sr i<D te9ftflODM80 i O i x131( 9mas33eno3du � W ' t �1 301W \\\\Ei//Il awe D OLL83W twMx39 Nourtrreie Wry.,3W.t r' AlMI90«DtMd NMYt WAL%'DCPMNO'LUi 1ran3%d QLGRLWd" drrtD JoflOMltelx3 ,1V1 lOf1DO31YToo aA A 3dU ONb= 3,SDCi1d 4aLYY19N31d 339NOILV8198 ONCT/dSJtlOddf16d0 1=-%MeIN !00!ted vt0VSTM7 3 � TY.]UtH�fu HOUISfdVULUOd l MO9B OUNf 3D9TY1d 3WDUd 'ddR7w11:Jf10 toM U3dV*VC"10(x1)ffWJDHI la' iI9DGHIImH)gO•t to fJNIR893dPJ39 NOLL03NN00YYgMl83/0M ONtedlYto 3iITtONHtl30MOHM IABf�aSU0i 1FAIVUISOtelx3OYtOH8JOf10• ATTVlR90e 4403)1(1 AOleW3B tAM ROOFTOP PACKAGE UNIT WIGAS HEAT SCHEDULE (OWFAB P,l81A8DDDNiMCT0it98TAUFO OOOLBGDATA FEATODOLTA t . COOLING R#1 CAA OCT. TOTAL 38824E B11*888 0411 DAB COW. 18012113 MNBL MN0FACTLW 11848243 CAPAt1Y SA OA 08.8 DOLING COOLING /*BAP FF41C83CY FANMOroR OMIT OUTPUT STAGE MD10R MG MIX;P V/PI$1O SILOS 110125 Al F � 88 (TONS) 841 8484 MBH 0.8JWB.. WI w MEN MBI NNA MM-1 YON( IIgM 4 7188 890 0.8 432 328 8888 14.6 1.5 24 86 2 119 24.3 3s 7840 AJ 84741-2 YORK •_ _ 4 18011 SID 09 308 33.7 8857 14 19 75 110.8 2 137 237 30 725 MI RII.3 YORK S 1880 824 08 Oh 4a{ 8857 14 tO 75 809 2 18 28.7 $ 775 MI A PROYIOELOWYOL1RIfE,PROMYfW/tE AUIOCtWiGloom TMBBAOSTATN80/CIEAR RAS77CCOYBi-W:SHEETAIS ITEM 710 8.18&2471024849l�IL1L$78RDitBA01LE0EifC10R 1iEOl.IRBABA8. 0.PROMOENi1HNMkF4G1U1�181TRO1CUN8M71HBURGIIA 848. 0.PNOMCEUNTMFRI Bl1ML881WLFY7VMBDONOVAZERV NB4AC1AER8Ci839₹MDCOMMMAKMAFPGE. .r E PROM*LDUNMUTWNB4F WOOONNBJMODUET. F.PWMDEI.MNIMFM.IOMYF84TN11*I88 AOCMRA1ELS O.MOON N PROJ�dS00N6CTSINtt51. Cl) H.PMO4DE UW4PANWT H RONTBNMCK LMSHNLSHUTOOM4LFONIIMM FROGI FlIMT*T01. �'.. J.PigNOELNTN1MMOWMYOB#9MIRCA7K8/ME+EATO08- U E)OMU1ST AIR FAN SCHEDULE (OYYTER ffiPPU®AIDDONIPPCIOR96WI8)) SP.N MIS MIS 881 TYPE CF4 8003 FAN FAN TIP 801ES FP11 VYBOHT MOTOR VWNH2 BA818 NOTE 548810 4584 8P® *882 84198. HP. 06104 LF-1 R7IAIOVB4HOODEM{FAN 1210 4* 122 183 OFIBCT 97 34 713.1(24 CAPTIVEAMEDUFFIFA MI 0.2 WMGWFMTFAY*HOWE LFAN 800 0* 1438 708- OPCt:T 74 1/3 11011 C/PINEAXEDW*fA AB 08-3 FESTR00MDGt FAN 24 029 881 19 OIIECT 18 88*818 11011/24 0704(07-144 C NOM. A ACC V6 INCLUD WENDED ROOFCUB1BGITASRC9LARED TO MEETCCOE-080/AROEOMM 40 ABOVE ROOFLL9@M8R NF08: COT STRUCTFDTOMEETKYA88&LL782 VAMLAL L$IVG RE0UPO. 8821088888 BFS 8iro74ECIRK241PROJECTOOI:UABIBFORAlLFACLM DMIBWLIL VBifYPROPEROPBNTKM GA ORFH0CLADBD:VENTEDRO1OABMMHBACKDRFFTDV84L 4 YWelll� MAKE-UP AIR UNIT SCHEDULE (O89ER84PPU®AIDCONI141CTORMSTAL1133 ' 5433 OCT. F4 48.8813. 104800 711x:pNF7Ina24 MAPK TYPE Qal FAN SP.M MRIT OUTPUT /8/1182424/ V48GYT MOTOR VAIMii BK180F OE81DN NOTES TOTAL ONVE MH2O MSH M13H PPM 84198. HP. 94.1 RL7EN®MM84PAF 9.888121F014 880 BELT 0.888' 892 796 7 11 CAPINEA9EA/.GM 1821 MOLES: A AOGti�OB2MCUA7®:2 ROOFCUB-843981111:NB4NS96F08:2•MMHIVBLE RLI*RF91FP8Y,IMMUL ISU88. B.REFER ro 13B'IR001 PROIBCT DOCUMENTS FOR ALLFE 54*B41*.00 B GRILLE,REGISTER AND DIFFUSER SCHEDULE (COMRIC70RroF18989HA8DF4BIM1) ��tipp F* 80441183 FATE8I* J MARK MtWFACRIRER MOOR TYPE 400#17011 1101E C8D1 11148 T88AA LOU.HiFD COG 941815 AS .0244. CSD2 111118 1M8?1A LOJ. CBL88 123.12 MI.D0.FAH 0800 11148 184544 l.OUYHEO WING 258@5 AH CRG 11112 3FatF ta4A LWLMO 2T117Y 2( 0 CBG TITLE 4*1. LW. 071145 12512 EP '_ _ 0185 A TEOK SIZE SHOVII1ON DR4891. S.4'88Y18 WPA11*4UN*SOMBNIBEBDNNCN*88W B. A8 C.BMIEOBBN88.FNBL BLACK 0 BN®BLYB RNIlH.VF4IE E PROVILE/6AFOROLDTCONECR014 F.BRNIOHOUCTSnIN MLBESMIEASNECK M EtM4OTH@eR8E SHOMONDIIN 84880 0.*8METMIETOMATO1407JNGCONSWCU5N,000ROBATMWMHAAO4IECNRFLFIF BOT6*8 LLRA L R NIMI&I4 1.TDON. J.FRONTSLAC63P/BMLL&TOLOWDIWE808T IOA�,$ - � K COMRMCOR PR.Y88NLFLTEAS-(7)285®5.1•THIXRBBKiABSFB.IERRE01AIBl. s _ y,. L RK7MOE8B10A24808AFKMABN®®TOMAICHAVWLOWONM.NB. 2; AIR BALANCE SCHEDULE • • .�,..7. EO UP884TU888 101/4 PB�iQ*A1® FR®N 2; & l10801 A9*LOW 08(0.244 O)1810P 580143.7 24213.045 80181089 ' .+ ' ,. P584247 AIRFLOW ARROW 417RFlDW PR18BAE mu-I ,800 7224 *8 - 300 RmU-2 1800 ,280 324 8A0 3 .,•3..Y ' mu-8 14M 324 600 ;•.. SF-1 OVB4 7210 - -1210 -7210 08.2 824 - - -60 4!088 li - - ff-8 W - 40 484 8F-7 240 824 824 1. R6U:7988 BU4DINBPRMUH0Al10N(OW) 210 _ 24. RE8UL1M0BUN31 UPRMURTATION-(+P4*4CR0EMLR.8 +(.818403.1018 R . :4 a NETMLRDWIS•+•CFM-1184.P0811NEPRF8BUE Y'A._a BETAMFLON•-0484-BLDO.NEOA1NR69KAE EP ..4C52447 $3.L' A 08.45785 • 9 STATE OF HI ROOF HOOD LLONTR400RroFUMBUeDMSTMy O 112 10}. MODEL CRJ 11840/1 PR6&AE NWHT MNK MINJPOCNY461 NMM 8431840E W CROP INLOS 88876 184 (84888 RH•1 aRWaEOc G78R8 81084231 24 8 008 7 PsB,C 492481 Nllwleu A Pf10VI0EYN1l7MN8FACRA68l0 OOFCLMWaHBIA2AR81 . 111ggs��4 .842 B.PROMOENMNBNESCIe t C.PROYDENMHBAOSRIFTDWVM. OPROVIDE WERNAILYINSUIX®147(17 MYBiP AIR DUCTFROMBF/LOCATED OS PROVIDE DEW THEIVA TATMOIMEDATMAFF TO SHEETlkq HJAC W ROOPTOKITCFIBIHCODWKHPNRODN/ECTIOH4,PROVIDE TRANSITIONS SPECgGTgIB FOR THERMOSTAT REOLM@IEWIS, t. BESUPP l BYTHE OM RNOINSTAUEAB THEMISTANICAl.P)8HN.1. t0. CWERALYREVNOTSHOWILIONTHEO6AINGS.fSfXFA PROJECT ASR . ESUPPIJID TS,ALL7HEPNERAIDISTAILIDBYIFELECIAIUL i[-0UIPBVBIi8 NOT8HDUMiW1MEOMWSXS. - OROOF Mmmer,PEMOTECONDESINOUNB FOR FREEMIVCOOUERSHOWN COHIRML170R.ALLTESAOBTATS,DUC RT1►i L iOi L6.ABOR HBR MkTER 1 SH1LL.BE FiMM&EIDNO INSTAUIDBITHEMEQQNCAL 11. ALLNDICTE)DUCT BM ARE YIEM ISM DNFSIONS. OONNgt INSET �MBR ANIONLOONTMMON,FBDVBFYMDUMNq FOR DAY. CONTRACTOR ASaAIJpFON OIDERTO ACHIEVE ODMFUElE 000E LOCATOR FBSi ro&IEETUS RJRADgRONAL NPORpNTON, 10 PROAWOEi$/4G MOLMT®F7NN.BT FAN IBWEN1�1F1001A BPUNCEPAN To GOAL~,AOPERABLENNMSYSTESASNgdTDNTTE PAW= 12 IIBANOMO BNANd110: F DOCy g SCHEDULED ORMADITBIOCI(OPEMTWWITH fEBTROOM LIGHTSW7TCi NJ.FNAC BW7E6 NSTALLED DUli1/67MBPROECTNE REOLIFEDiO 7YPEIBBMIISCOATPWAOl9S FIMStED BY ClNNHiAFONBFNI.ID BY Ni 2. CONTRACTORS ADSUBCONTRFCLORS NWLCREFULY IiEYEWTHE BE PROPER.YBALANCEDMANROFP9MN`I!.THIRD WTNM .,: M FG 1t PRD�AOE OMWAa DUCFFRCMCSUNDMOUNMOCI WEAN.T6i�f1ATE COMPLETE CONSTRUCTION DOCU IENTPACKAG?.NFORMATW BAAWCSIGABER.Y.1 TAB'CONIRA.'TORM_¢!T_BEAABCSrOR IfOBAAflOII W ITHWAIERPROMA00FOPW1TH18IDSCMEN ROOF HOODTOBELOCANED L A UAABSE OF tOL'FROM ALMEOMMCALARINWVELOCATpS. THROUHOUTTBOOPEOFTHE ET AWCANNTB® ROMPTO1F�WBESAPPROVA FOR 7FECHANIA ONTR O/ OOMECFAWELL>®SMELGREASEDUCFTO ATTE ROOFATINBCOLLAR 1H10UGHAnIOLEPROIe4CEM7WCDEKMPFO.EUTDOOL 47ar REC�TOFTNE OMW@LBAPPROIWL,THE IELYMtiOI1LCONIR•CIDR AIRVO 10NABFEDURM70MNFB !/>ROOFJC FIBOR is PROVIDE P-VC.Mi�WMA R IMLMM NCOOLER ADFREEZM oETNmwniOlrrR�llLBroTHE..C'd�FLEiEPROJEcrooaA¢�LF aNw.Le+avBETNEAPPFLOJEC�r81�(ILBTINaaeALML1+f� e�TO TNEmELF�LrneL EBwLBTNDOOAB BNiO1Wa Be. CONTRACTOR 7HEOLAT BHALLBEWWRAPPED¢1ACOgfiDMICEYMIH iH6� to NBTAU-HOOD MA&FAOMa8i FLIANISHED EMOTEKITC HN TEMPEMTUIRE ', ISiRIlICiIONS)WTi 1-t/1 TUCK FiEfiMBTHLLILICFW/RAP,AB ApNk1FAOTUIED SENSORATC9tq. A COOIDSLLiFWBMTHEWORKOFOaM*RANDVATHJIIPMBiTFLAlR(M OF TE&.R9EOUEMT481EPOR188NYLL BE OIBTF®U1FD BVaM CQ lOF10TN6iAPR10A�EOyM.lAS1�li�,NQ90CitFOAdtVE OYOIIES,FEOUPENEIONSOFIHEPROL,MDWIR FTERGANEFUL. YTOT£OYWERaSWIIL T�RCL/L®TINOLRiHT1E OgFUANCEWRHTE BODE RB01#EDOREWE DU0TL9K1OBURE WRAP 14 SBTML NEW RTUpgROOF qBg 000LONATEMM NPO CONSTRUCTION OFTEED441EPFJDAIFIDOMU}EPND.[C.FE00aiSM OI OOMNMCTgW SE F,7€paLRBFIOULD SH41 SCIEDFROM THE DUCTCCMECRONAT TEHOWTO TEOL1CT MANAGER AD STRUCTURAL DRAWINGS FOR EXM,TRTUNSTALLATK7N M UTE FVIEPRVIGIIOOGYDII1867FBiSEO a70CLMMENCIG D®IFEIO.PHFORM RTE-AFAI IXH N NfAMNICARXL0 PEETFN110lNWNILEMONATTEROOF/CUB COLLAR,COMPLETE LOCATOR MVNTMI ALVANLFACIURES CIEMMNOES FROMA0.MCSR WORK. TMWBIINL+1)oFANY aBCtBWNC�p�roLTOMAEicIKG O UGUNI TATION FFiFGX FRU MfKXX Off? EGMLB3174INFDUCT A W,AFEE RBOUN®.THE EdDFMENT. 1i0.7fW(. E mg>warALo NOFREMOLB PRDECIH T8e EERENT®BY TIE 94ALLB PRESENTRACIOR.IICINERF CORC3 MAMPAGTSEUB NSIRUCTIONB.1FE'ONNB18lPR�'ROOF CURB MALL BE 4. TEORAWNOBWR TIEHVACWORKNEMVME14REQUIFEDTHE17E OFT£IBN OUtEPORi8.SFMU.BEPfEWH1'IH)IOTEOWBERFCR AWAUFOFSPNHEIGHTWHEI UTL2BETHE8PECF�,TiWRBfSUPPLEC' DWMMN IODATION, LAIVUt.ADEOIiN@4TW,TIE HBREWaCALC 7RWFEVIfl11MPPROVN,Ri0CEB8.FTE EBiASTFANL THE OWNERSHAeU*IE THEHOODaLBABBOCAAT8LFM1 THEARC 88HLL BNWINGS FOR EOCTAE/BUIiE61T.RfFBRro MEd1AMCA.CONiAYCtOR DOES t�¢jPFID'VDEIFENECGABAfN (WWII OUIBI.THE AECHANOALCONIRACiORSHALNSTNITHEEQUIPMENT, V 1HEARCHiBCRB►1L FVWM108 FOF1A�OIENIBIOIB.RE@i 1O 11€ DOU.MBITATION,OR F THE PRESENTED DOCUMENTATION DCPB NN AS SHOWN,PROVIDING TECONN DUCTWORK 9P.DUCTWO WRAP.SUP PORTS,& MAIPACTIRESSNSTALAMON CRAYIIOBFCR�IIFABITOCNfSCLIONS 847ISFYTHEOWNER TE'RRiD PARTY'TIEAGEaYWn}BE - OTHER APR.FI9F2 MABMOUMFORACONRETEAOFBVBE9YS1BA AND 07MM NBTALATONFEOUIEFABRS.SAUTSHOP DRAWNGS FOR RECLIED. APWgAA., ECFCATON REOUIRENENTS. _ O IYPEIDDiALWHOODATFRYE6 R.RMBHEDBYOWNE ANDOSTALEDBY AJY'rWOOCUMEIFATDNREOLWMFMACEiTFOAMOF MEOWBGILCONIRACfOR REFEI1O8FffTW PORAO01110NML A ALWOTWUSNMLLOOWLYVMALLAPPUCEIACAL,SFATE,a WLTQLLL OOCIPAN(.YSHNL BE PRONDEDAS PAW OF TE SASESCOPE CF NcAM7 CORM.ASWELLASMUB YSFMD4DB.M FSMARD WAORKMADWRONALSEFMMFEES&ORC061SWLLBE OON57R)CIK*WaTALLAIIONPERLMSHWLBEPLFAIVMDMMEEOM. EIIEITANWFWOAEMim RHAAi4P4N4&AU.'T8B' a �IpELTAY/E1DEDeTE73 GfEA8E dlCf1D ATTIE ROOFAxIHB00LLAR UKEWMALL Lp�SMW48PBMKM*ALBESCMEDUED, O &TBi DOD► AMOK SHW.l8E DB7iBU1®ro7NEOWN81 y PERFOAAtD,aALPERNEifGMB"iECTALAPRiWABDBRF'ATES AFI =61APPROVA,F{ARN6LDB8B.RIA1pNOF THE&MCf= a7R4HLI0NASFEQLNEDMAIkr VVELD®SR�GFEA9EDUCFFOR OBTMJEDaPR�tl®ro7HE OWNER WiO TOAOiEINGSAWANMI DOGR€NTATON CN OCCUR E�CTION 10 THE TYPEIWMNGSIREEfFLNEREISLAST HOW AS CO.FE1 1. _ 87 &THE DUCTSH41 BE WRAPPED(NACOORDANCEWWM ENE REOUfE0 MEASI.N aIB0HN OU®: MYMPACR TIERS INSTRUCTIONS)WATN 1-12 TMd(RREMSTEi DUCT WRAP,AS a WIEN HVAC AR ROW B OVERD000FM PROVIDE BL40KE DUCT DETECTORS MANFACTUREDBYSM 00.108 OT1ERAPROW®EEIALI AS REDUPED,IN NSUPPLYAD REURN DUCTS OR AS REOI/i®BY APPLICABLE OOOEB. • AL DF-lAB6,REGISTERS,MORGRLLEB SVLLBEMEfrS& OFCMTOAOH#VECOMFLWiCEWRHTE000EFE0UIBUfEIEABEDUCF EOXOW 1E WRLW SHAL eCTMFROM TE DUCT WNIECRONATTE HOOD DUCT'JAOXEOETECTOReWILLBEBNRDLRDIOEECRS#200" BYIJTM@XGAHOODA16ALVlNEVECMEiEi� 1O11EDULTPBiELMTON00MECLIONATT#ROOFAC7UfBO0LLAR _ BRIECIOR MB FFLE#0II,M1.N000TOE(8P&FLNGTUBE#800606LB. COMRETETHR000HOLfrTiEENRE LENGTH F OUCTACCE88 DOMEAE SMRDUUTDOWRLA St1,£L SE99 tE(# M(kBEi0NAIA7. • IOTA.FL13 OFTERMINLY DBYPROTTUS:TR0WEARIN AIi REQUIRED,THE FIFEPROIECiNEWRM MAT BE NBTALLD1WA00FLUL PERTE HYICBHUTOOMLSHALL SFNLLBE*40DW IWITH 10.RREAARid 8Y8fEM68H1LLBE 0EIEMaNEDBY RTOf1UBE1MV13iBFO; MANLLFACTtF 9BBTFcnow T£'OMFABUPRJ�'ROOFCLXBBHWLLBE 00MROLPAE1. 7t ElIEPIFX P40Mit01 WITH RIO BIVPIEX a2Ai AMMAUMOFY2 i,2 N IBIi4T,WHB4 UBJDIGTESPA,1AF BATTERIESIPMAZN28YSTE SHALLBNUTDOWN LIRAS UPON • URUTERWALLWVCXU DAWM7DB4AOCENl.400542541. A BLFPUHY EBIAST FWA THE OTHER SHALL PROVIDE THE HOW&ITS ACMATWOFOUCTSMOKEOETECTORWfGiWLLSCLMWNBEI DEVICES PER THE PROECT DOMM911M RFAUf®AFOUAIRIES. ABBOCIATM FAWAT FAN IWTH QJRBU.TE MECWK9tL CONTRACTORSWLL NOAICTIIIE LIGHTLOCA7®N 811WOM FI EALMO PAIR FIE MAIN CONTROL PAt86 ONLY FOR MIONPORINGACTIVATIONOF OR • HOOD SHMWSYSIB48 SHA.LNOTBEAOMPTW,F THE - NSTALTHEEOUPMEIT,A88HOWNRROVID 7K ECONIECTN000CRVOR( TROUBLE WITH DUCTSMOKE DETECTORS.MECtANIC&OONI ACTOR SYSTEMISI CRMBEAWIMIDKDATEDFJSWIBTAIROUWITTY. WWAIRAIPPORiS.&OTIBt APPURIEAM ABRECUIEDFORACOMPLEIEA SWILL PROVDEAND NBTALLOEVIC@TW COMPLYWMM NF.PA BM 4-A UEMABE.THE HOOD FOWWBTBY87B€BHALWOTBE F / OF'8AAE SYSTEM BECI &CONIR4CIORSI4I4L7 PAELNDSMOHTEDETECPORS. 11E BYSE#ISWOE 1WW8%N ELC 88OF17€Pf A1® - MOOW.11MenN E76WATNROlANI11<8. O.NSTALL OWRERFUI B/�HOM PRO'DEANBUL(OROIHER AP OVMWD IN4AS EDUAL)FIRESIPPREB9ICN BTVIEA FOR PFEiFBU HOOD. IBIS IL>s I7Ks6 PAC SItSI W GENERAL NOTES f 3 KEYNOTES J 2 REL D VBW&AIIG1•NOIES: RE7BEEWCPNORX&i41M0TECSDeCNL&IGMANDSIALtMOfRE 1. CODE RBGHASIE]Mt11tMdBYAtIL$♦ IY�IARNWfEUGARTIONS,MD ^; fi ', = IIDWLffiMMAOL>NB[AmR. E7IW1•'t4RFLUE DBOfU7G3EU0OMIDliBFAU.LEPRd9lYJiWFAS . . AVOVWV PBMMA DWAO1B AA'BLIBPIg7'ANOPFELYNSTAt11DYWLL9E A1000E1E0llIr�OBI3A0NE11CN1tEYWSIdJtAPPURlEWIT SIWBL .• t@LArEDATCONFALTORN PJPBBI. -,.k,.., BEIEYEWBL VEFI�.ACOd�tLit®iLYTiENELYAPSOAL'£01IDMG�Ik A1Q'BBSFWWLBEDEi1FWTE.ONNERORONNES -SJ IFATNE NWN10N. THE CONIMBR F'B4TO • OONBfRUC1 $S€TAW1E GFEASEDUCT ALTERNATIVE 2. THE PROPOSDTFAXECTTFAM APPROVE)`LOCATIONS OFyL ROOFIAOIMIED EOMPMBITSKI LBE PRESENTED 70TiEAMANDL I AS AN AIE14MINS TO FEDFABHCATIDGREW 08WATOUCTAS SPBgFED. FOR TEIRAPPROVAL 0EOUBEOj. ro T'HE COMENOMIENTOF _ TION�DRaveiGPaR UEWITH TY EI KITMYRHOODST ATC MMT EFM013 BE OF FOR COHSflaICRONRBTALLA PROPOSED wAL. If UEWiH1YPEigiC4BIHDO081W1TC0lFOISAroTE RE0UI1E1BIf8OF Lotl11DNS.FRrDONQE MA'DBGRBANRT$, IL�BitYq TTE ` NPwFIe. PROP MLOCRIlOSI RAPPROVAL PRLSE I5SI-SILLEThLO tTINUO S ERNAL TE PERAT RE OFa IWLL EOAIAT 8 7 DUCL88HiALL8E PEPATU RA00202rF. NTEWYL IISVFEM7URE OflAOF A►D a VSI yTHEAVNABIENBOVE CEILINGCLEVi8PAOE'FORDUCTSISTALMION NIOOD NIEMi1ErtiEVFEA11I80F0D0'F. P�ro1HE COAEBJCE.BITOFMiYOUICTPABp01TRON.AICWS'ABOVE t . BABEOFDMMPMFACFWYBULTG%WDUCFSFALLBECAMMME IXF FOR'CII t I - MFBC8.F iHEDUOIW01Si8HW1DOFJDAB NODES OW4q OW48R ANDCW,OL PRCO=SHWLBESUSMRED FOR iEOIA� 71E BWJOSOCFROUINGOF THE OUCTN1 liiiTHE 1ST i MRRWAEFTEBDES,ROFRBCORDNA000RDAPICEWMPRDEf.T U �WNMIYlOC1111,THSBNUBTBEAPRiOVED BY 77€ 7x7 I I SPECFCJDIONB ANDRCQLAREBRB OM4M MWRTOPW&LA7DN.UMW Mi.FTW UMONEVMMAM M r �. E STALLAEfl.TE RBISIOMAIA00FCAT10NS MUBTBEA'RIOYED a liiiCSD7 I I ORroPWTAUIION we 4 Ill! 12'0 1 e - MI NAGERP R 110NOFSAME IHI YBNH UPC FA J> IIEOT ,2 ---- — II W'8 - A- VERFYAVMAEE ELECIHCALBYBTEAVOLAGM A000RO/LMEWIIHAJLTO CSD1 4 1MB 20 I BE&1PPI.EU'EECiWpi. $60LAPhB7f. i[CMi OVEN . 1a II \ t e to � Ceoo ;a I —_—I. eeo I 141 `Li: " e0 L — 400 S 1010 Lb01 `�°' Ji F ilUM OUrDOOR AR yY 300 800 t2 800 PBORE ORA191 CFMWEI ESWUR CODE 4 Na OJOS • AEA PBiImU PEMON 8Q FT FF:d/� NO E 'o aGtlE OF' 4ai ISO. Ba Fr Wa cao /o p1 n woe to►_ 1S0 iS0 90 _CM • d - ASKS W ,t . - SOFA 16 SFFBFTNUISLSBL PEI AR BAANLE Sd®UE IS00CFAOFOUTDOOR ARMIES PPU®ro BRACE. Ml H.VAC.FLOOR PLAN I +N'-i+e 1 FIRE SUPPRESSION SYSTEM estaurantr /- izza Hut Hood-11' 1 W 1N 1N Hood-5' 1W Zephyrhills,FL 33542 r � r r-- -- _- ------- ----- -- — —J 3N (4)245 ire Equipment Contractor: F ANSUL 6 Gal. FIRE FIGHTER Inc. P.O. Box 888 Remote Pull RENEW DA (c - °) 4330 Alpine Rd. Double Deck Pizza Oven 14"Fryer MY OF ZEPHYRHILLS Land O'Lakes, FL 34639 FIRE AND LIFE SAFETY EXAMI (813) 996-6469 la.St.Lic#: ALL WORK SHALL COMPLY WITH 01350500011997 NFFA CODES AND STANDARDS ali er: 4f Gary F. Blair £