HomeMy WebLinkAbout19-20739 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20739
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
,PERMIT INFORMATION LOCATION INFORMATION '
pPermit#:20739 Issued: 1/30/2019 Address: 35933 SADDLE PALM WAY
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 383,685.90 Total Fees: 15,775.19 Subdivision: SILVERADO
Amount Paid: 15,775.19 Date Paid: 1/30/2019 Parcel Number: 05-26-21-0080-00500-0210 �I
CONTRACTOR INFORMATION OWNER INFORMATION I
Name: LENNAR HOMES LLC Name: LENNAR HOMES
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,406 SQ FT
APPLICATION FEES
BUILDING EE 2,074.20 ELECTRICAL FEE 441.00 PLUMBING FEE 294.00
MECHANICAL FEE 205.80 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,728.00
SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
W ,/ C11
i
i
Inspections Re uired
FO TER 2 D ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC. i
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC. !
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the�
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or i
first renspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordancei
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATUR PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
PASCO COUNTY, FLORIDA
Permit No.
Date Permitted
Builder Name/Owner Name knAer Control
County Parcel No. SubDiv:
cfliLrada
Address/Location 3V33 SYA�w )4'1'0�
ClassificationlType of Use 54/
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit J*1-
Exempt []Yes [] No How Determined
Impact Fee Amount $, chi 632_.,60 Zone No. TAZ-
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ 7i 1910s�
(057) Mobile Home
(058) Other Residential
23) Collection Fee
Exempt �Yes n No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit -Recreation Total
Zone TOTAL AMOUNT $ 7
Exempt F1 Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility,Account Facility Credit Facility Total
Exempt F1 Yes ❑ No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By A�� Checked By
U
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID.AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICS OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
tvl 6-1 tsU-UUZU City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
.Date Received Phone Contact for Permitting813 363 2891
Owner's Name Lennar Homes,LLC I[L11 I I I
Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
35933 Saddle Palm Way
JOB ADDRESS F LOT# [0210
SUBDIVISION Silverado Ranch Subdivision Ph 6,8,9A PARCEL ID# 05-26-21-0080-00500-0210
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR ADDIALT SIGN DEMOLISH
P INSTALL H REPAIR
PROPOSED USE 0 SFR COMM OTHER,
TYPE OF CONSTRUCTION 10 BLOCK Q FRAME STEEL
DESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure Pence
BUILDING SIZE I U/R SF 3406 SO FOOTAGE2576 HEIGHT 1 Story
. . . . . . . . . . . .
VjBUILDING VALUATION OF TOTAL CONSTRUCTION
0 ELECTRICAL 1$ PROGRESS ENERGY W.R.E.C.
F*X_�AMP SERVICE
LIO PLUMBING
MECHANICAL VALUATION OF MECHANICAL INSTALLATION
"I F r-
�f I
=GAS 14 ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA CIYES Do
. . . . . . . . . . .. . . . . . .
[L�Homes,LLC
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
T Address 001P
4600 W.Cypress St.Ste.200, a,FL 336 License# GC1518166
1 I
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE Z REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Skipper Road,Tampa, FL 33613 License# i EC1 3005408
PLUMBER COMPANY 1Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN L_Y2 N_J
0
Address P.O. Box 5308, Bayonet,A 34674-522!�— License# [CFC042998
XY AN
MECHANICAL C: I Bayonet Plumbing, Heating & AC, Inc
OM
r'
SIGNATURE R .rST E R IE D N FEE CURREN
Address P.O. Box 5308, Bayonet,$1L 34674-53,W License# FCXC0758062
OTHER COMPANY I.0 Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 14211 Shoal Line Blvd,SprikHffl, FL 34607 License# I CCCO57991
IIIIIIIIIIIIIIIIIIlIII IIIIIIIlI111lIIIIIIlIlIIIIIIIIIIIIIIIIIIlII:I
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . . . . . . . . . . . . . - - - - - - - - - - -- -
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2600,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RE�T�C� � undersigned�� Th� und� �and that this oann�may be subject to"deed" restrictions,"
�� n� � mo� �rictive than County regulations. The undersignedassumes responsibility for compliance' with any
applicable deed restrictions.
UNLICENSEDNTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors ho undertake work, they may
' be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as requirmd by- law, both the owner and contractor may be cited for 'a misdemeanor violation
under state law. If the owner. or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at,727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign an the
contraotor, tkotnnaybean |ndioetipnthotheienotpnopmdyUcenmadandianotentiUedtopenn|tbngphvi|eQmeinPesco
County.
TRANSPORTAJ'I0N |88PACT7UT[LQ[ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned undenobands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing bui|dingo, or expansion of existing bui|dingo, as specified in Pasco County Ordinance number89-O7 and
SO-O7. 00amended. The undersigned also understands,'that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving o ''oarbfinateof occupancy" or final power release. |f the project doasnot |nvo|maeoerUfioatmofoncupmncy
final power re|aoae, the fees must be paid '`or to permit issuance. Furthermore, ifPamon County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco Countyordinances.
CONSTRUCTION LIEN LAW(Chapter 713` Florida Statutes,as amended): |f valuation of work is$2.5OO.00o[more, |
certify that |, the app|inant, have been provided with a copy of the "Florida Construction Lion Law—Ho0eQwne/o
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. |f the applicant issomeone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver|tto the"mwne(' prior tocommencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application ie accurate and that all work
will be done in' compliance with all applicable laws regulating conotruction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. | certify that no vvodv or installation has
commenced prior to issuance of permit and that.all work will be performed to ma*i standards of all |avva regulating
construction, County and City codes, zoning nagu|n1ionn. and land development regulations |nthe jurisdiction. | also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my.responsibility ho identify what actions | must take tobe |ncompliance. Such agencies include but are not limited to�
' Department ofEnvironmental Pndeoton'Cvpnaoo Boyheadn, Wetland Areas and Environmentally Senoitkxa
Lands, VV6ten/WaotevvaberTreatment.
' Southwest Florida Water K8onogarnent Oiathct-VVaUo, Cypress Bayheods. \8AaMand /\muao' Altering
Watercourses.
' Army Corps ofEnQinmmrs-8aovvaUo' Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks. |
- US Environmental Protection Ag bmstooabatement.
- Federal Aviation Authority-Runvvayo.
| understand that the following restrictions apply to the use offill:
- Use of fill io not allowed in Flood Zone Wp unless expressly permitted.
_ - |f the fill nnsde[ia| in to be used in Hood Zone "A". it is understood that drainage plan addressing a
�
"compensating volume" will be submitted at time of permitting which is prepared by o professional engineer
licensed by the State ofFlorida.
- If the fill material is to be used in Flood Zone "Af in connection with o permitted building using stern vvaU
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill nnobaha! is to be used in any area, \ omrUfv that use of such fill will not adversely affect adjacent
- properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for.violating
` the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated byfill, on engineered,drainage plan isrequired. .
If | am the AGENT FOR THE OWNER. | promise in good faith to inform the owner ofthe permitting conditions set forth in
this affidavit prior to commencing oonstnucdon. | understand that separate permit may be required for electrical vvork,
p\UmbiDg, oigDo, vve||o, poo|n, air coOditioniOQ, g@s, or other installations not specifically |no|Udod in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
Un|aao the vvod«authorized by such permit is commenced within six months of permit isauonoe, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be roqueatad, in wMUng, from the Building Official fora period not to exceed n| (SO) days and will demonstrate
justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY'RESULT /N YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU.INTEND TQ OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
OWNER OR AGENT CONTRACTOR - - '
Subscribed and-sworn to(or-affirmed)before me this Subscribed d
Who lslareijers�nally known to me or hasihave PFGdU Who is/are personally known to me or has/bave pFeElue
as identification, -as identification.
Notary Public NotaryPubnv
Commission No. FF98537 Commission No. FF98537
EDosyM.Holleran ZJisxuM.I{oDeruo
i
i
-,T - AMILTON
ENGINEERING & SURVEYING. INC.
February 23rd 2018
Mr.Bill Burgess
City of Zephyrhills
5335 8th Street
Zephyrhills,FL 33542
Phone:913.780.0006
Fax: 813.780.0005
RE: LOMR-F Sllverado-Phase 6,8,&9A(Plat Book 75,Pages 75-80)
Lots 17-26 Block 6 and.Lots.1-3&19-27 Block 5
Dear Mr.Burgess:
Enclosed is a copy of the application and associated data necessary for the review and signing of the
Community Acknowledgement Form that accompanies the LOMR application to FEMA.Please return one.
of the copies of the Community Acknowledgement Form signed for submittal to FEMA.
Enclosed are the folio-wing items for the above project:
1. Property Information Form
2. .. Elevation Form
3. Recorded NO
4. Current Effective FIRM with Lots plotted
5. Signed/sealed metes&bounds descriptions for Lots 24-26,Block 5&Lots 18,19125;26 Block 6
6. 2 Copies of the Community Acknowledgement Form(Please return one)
If you'have anyquestions or need additional information please:contact me at one of the contact
numbers below.
Sincer
Ric ack;P.
Vice President
Hamilton Engineering&Surveying,Inc
Office Phone_:813-250-3535 extension 111
TAMPA OFFICE
Fax:813-250-3636 3409 W.Lemon Street
Tompa FL 33609-1433
Email:RichB@hamiltonerigineering.us p..813.250.3535
f.813.250.3636
ORLANDO.OFFICE
775 warner Lone
Orlando.FL 32803
p.813-250-3535
W W W.HAIATONENGINEERINGM
PLOT PLAN SKETCH ONLY SEC. 05 TWP. 26 S, RNG. 21 E.
NOT A BOUNDARY SURVEY
LOT 21, BLOCK 5 BEARING BASIS:
SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E
PASCO COUNTY, FLORIDA. T
1\�L THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
PRELIMINARY DRAWING: EASEMENTS AND RESTRICTIONS OF RECORD.
THIS PLAN IS FOR PERMITTING PURPOSES n0 )
ONLY, NOT FOR CONSTRUCTION. VERIFY UNDERGROUND FOOTER, STEM WALL, AND
II UNDERGROUND UTILITIES ARE NOT LOCATED OR
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SHOWN.
LEGEND: DO NOT SCALE THIS PRINT. DIMENSIONS AND
-AAA,— = PROPOSED DRAINAGE FLOW v NOTES TAKE PREFERENCE.
(00.00) = PROPOSED GRADE �^
E-00.00 EXISTING GRADE DESCRIPTION NOT CONTAINING PLAT BOOK AND
PAGE INDICATES THAT PLAT IS IN
PRELIMINARY STAGE AND IS SUBJECT TO
NOTES: CHANGE AND/OR REVISION.
LOT GRADING TYPE = B
PROPOSED PAD ELEVATION = 100.3' `�OJ CERTAIN DATA SHOWN HEREON BASED ON
FRONT SETBACK = 20' TRACT E ENGINEERING PLANS PROVIDED BY CLIENT.
SIDE SETBACK = 7.5' DRAINAGE AREA
STRUCTURE TIES SHOWN HEREON DENOTES
REAR SETBACK = 15' / MEASUREMENT FROM FORM BOARDS/FOUNDATION
/ TO PROPERTY LINE.
3• /
n�q / CJ • = 10' UTILITY EASEMENT
Q:sf St7 +i = 10' DRAINAGE EASEMENT
4.
LOT 22
BLOCK 5 (98.50')
F /
J * /
�
011
CO / o� p js•. \
N� / lb^0l\ Cq sOpOs�p A Se
2 i Rq eF44,,qlv
% R/phpq �O
LOT
/ BOCK 15 �.' ON LOT AREA CALCULATIONS
(100.00') LOT = 9325.55 —SQ. FT.
Q'\ LIVING AREA = 2576 SQ. FT,
ENTRY = 57 SO. FT.
LOT 20 GARAGE = 674 �SQ. FT.
O BLOCK 5 COVERED LANAI N A SQ. FT.
'-b PATIO = N A SQ. FT.
�;N •��\ g'' d °o POOL AREA =_N A__SQ. FT.
CONC. DRIVE = 581 SQ. FT.
° ^ a pp'° r� A/C & CONC PAD = 12 SQ. FT.
—fib—
�� l ss• FLOOD PRIVATE SIDEWALK = SQ. FT.
FLOOD ZONE IMPERVIOUS =42
ZONE Cr. ..� ° A = 3930
—_SQ. FT.
�` •�.• :: � s b :ry;� ._.._.._.._.._.._.._.._.._ S� = 5396__SQ. FT.
OFF LOT AREA CALCULATIONS
FLOOD RIGHT OF WAY = 1114.82 _SQ, FT.
�.
ZONE DRIVE APRON = 350 SQ. FT.
FLOOD "x" PUBLIC SIDEWALK =_315__Sq. FT.
ZONE SOD TOTALS sQ
"x" �Q\
Opi�j AREA =_10440.37_SQ. FT.
CDRIVEWAY = 931 SQ. FT.
rs'�jy d\• SIDEWALK =_345__SQ. FT.
SOD = 5846 SQ. FT.
DESCRIPTION:
b PROPOSED:
LOT 21, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION LOWEST FLOOR ELEVATIONS:
PHASES 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 LIVING AREA: 101.00'
THROUGH 080, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA:
ELEVATIONS REFERENCED TO
CURVE RADIUS ARC CHORD BEARING DELTA NORTH AMERICAN VERTICAL
C136 225.00' 63.56' 63.35' N 62'07'32" W 16'11%6" DATUM OF 1988. MEAN SEA
C137 225.00 49.64 49.54 N 47'4247 W 12'3825" LEVEL= 00.00 FT.
C141 350.00 66.12 85.91 S 56'2918 E 14'05 55
APPARENT FLOOD HAZARD ZONE: "X&A" COMMUNITY PANEL NO. 12101C 0288 F EFFECTIVE DATE: 9/26/14
Project Number: Square Feet: 9325.55 t LENNAR HOMES
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE W F= WOOD FENCE
JOHN R.BEACH&ASSOCIATES,INC. Drawn y.
y SMS
_h SURVEYORS AND MAPPERS Checked By.
911 WEST ST. PETERSBURG DRIVE JRB
ONE OLDSMAR, FLORIDA 34677
WAY (813) 854-1276 FAX (813) 855-8370 Scale:
1 30'
NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 10/8/18 JBS
THE ORIGINAL RAISED SEAL OF A FLORIDA S AT DA E
LICENSED SURVEYOR AND MAPPER JOHN R. BEA
Revlslons: FLORIDA REG. L D SURVEYOR No. 2984 LB 4493
JEFF M. HARTLE
P 0 RVEYOR & MAPPER No.71
Nfy
`' l 'V�}' f `t f'3Y yVI
K1 + n •
4 PAD:LOT 2
h" L 26:_gg 1' :10
PaD1Q3.5 gg _gP SOT
jai � �o� rYP�.� r �� ' _ TrP� s•'� '`; �`.,. �.� �,. ,;'y°.> t �;� � t'*i ,,y��.
,.
p 1 5 •44 ; �xaa s+ :aa` _ d� --- w, ,.,.`..<. $ p�2'+ '.g�° . • 1; �f'
t �fl1 LO 0 QD:6 �`.,,• ♦ , .. ,14,p
PAD 26 ', ob t ', TYP,� g. , ,. :.f,.." -, + ', 6: t "•. ,
TYP6a4:8 g� ,ioo' 3 b . . e.�s' $• �
at. x40 47 '�. '`fix -300.05 1 �b ++ g. cd� NIAlorl. ( t;' "� $7 S ka 4 42
{(�
f '
' ..
,,1 0 V,&
27,
PAD
v"1 Q6.iG � (�. xs $6 t r\ }`. i,.'a 't �ry ,1 w, `�\
Ptbt 4 .rr' '' L1 ,.... g �A . t ..'{{ 7 `* ;.��. , ,t q
tt
20
.so. �?ADct00.4 � . .g1• `` ' g`�
,/��r
V J 9 6 , ♦ � -�`i �C�'� I1Y�) i w'w• '``ti ��`- ''t4' ��ry�v
LLL {VY �S
Q7 ACC � 1�� 5 't '� FF=10 1.30 `' �9 '• + ♦`
--T�'�.�0 � � COT 19 . g8.5 , f1 �• ;, .. �Fp(} 4 9D '� 1' PAD�100.6 b
2 t 2 ;� N,9
37 i ': T?'P g Og' .', 0 ', 1 t ~;'�►
AU"104.2 ,�q0 ♦♦ '/)
L
FF_ Q `.gyp t � � � �� ga �.�2 ., , `♦ ''
Q 3 LOT �,0ry �`` ��� 1 +s`, ` r {s
1 s ` PAD 108,3 :{ FF=f U 1; 0 9�s0 4 �' LOT 18 gg.0 g�' • '', �'� �'
� A PLOT ;� `4 '7 '/PAS?_AA. Sti 7 5 .} s♦�.�N ♦; -Cot- -. ADa 101.1 6 � TYPEgv t �'� ', 4
'TYPE �{ `� ,, 2 `;s 's gg 4 ,
2 . ��y �, ' top` ' ' F• g4 ��' 4'`. 7Q'' �•.: t, ♦+w
'+,PA OT.77 oil,,
01.0
t3 '.60
1' a [/h�� �y/� S
t
• 98 0`
i
PLOT PLAN SKETCH ONLY SEC. 05 TWP. 26 S, RNG. 21 E.
NOT A BOUNDARY SURVEY
LOT 21, BLOCK 5 BEARING BASIS:
SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E
PASCO COUNTY, FLORIDA. T
1 THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
PRELIMINARY DRAWING: EASEMENTS AND RESTRICTIONS OF RECORD.
THIS PLAN IS FOR PERMITTING PURPOSES M UNDERGROUND FOOTER, STEM WALL, AND
ONLY, NOT FOR CONSTRUCTION. VERIFY II UNDERGROUND UTILITIES ARE NOT LOCATED OR
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SHOWN.
LEGEND: DO NOT SCALE THIS PRINT. DIMENSIONS AND
—um.— = PROPOSED DRAINAGE FLOW v NOTES TAKE PREFERENCE.
(00.00) = PROPOSED GRADE
E-00.00 EXISTING GRADE DESCRIPTION NOT CONTAINING PLAT BOOK AND
PAGE INDICATES THAT PLAT IS IN
PRELIMINARY STAGE AND IS SUBJECT TO
NOTES: r CHANGE AND/OR REVISION.
LOT GRADING TYPE = B
PROPOSED PAD ELEVATION = 100.3' \' of CERTAIN DATA SHOWN HEREON BASED ON
FRONT SETBACK = 20' TRACT E ENGINEERING PLANS PROVIDED BY CLIENT.
SIDE SETBACK = 7.5' DRAINAGE AREA
STRUCTURE TIES SHOWN HEREON DENOTES
REAR SETBACK = 15' / MEASUREMENT FROM FORM BOARDS/FOUNDATION
/ TO PROPERTY LINE.
3• /
/ C • = 10' UTILITY EASEMENT
>' o/ : Sty •+ = 10' DRAINAGE EASEMENT
/
4.
LOT 22
BLOCK 5 / gin,: (98.50')
J * /
4(/
N / gyp•. \.
cgRgpFF�FI'�qN
• � R/�yTq•• �O
LOT 21
BLOCK 5 �rV ON LOT AREA CALCULATIONS
(100.00') LOT = 9325.55 —SQ. FT.
LIVING AREA = 3576 SQ. FT,
ENTRY =_57 _SQ. FT.
LOT 20 GARAGE = 674 r- t; � SQ. FT.
°v �� t'ti O BLOCK 5 COVERED LANAI = N �SQ. FT.
. TPATIO = N SQ. FT.
�'N � \\ o<: d POOL AREA = N SQ. FT.
.i s * o: 26 �j CONC. DRIVE = 5B1 SQ. FT.
d ry ��. �. 00, > A/C & CONC PAD = 12 SQ. FT.
�� a° '•s6• FLOOD PRIVATE SIDEWALK =-3�-- SQ. FT.
FLOOD ° A Z�� ONE IMPERVIOUS = 42 %
ZONE ,. . ° � . A'
� = 3930__SQ, FT.
,.A. ... 36
SOD =_3396 —_SQ. FT.
v q :"rye
OFF LOT AREA CALCULATIONS
FLOOD RIGHT OF WAY = 1114.82 SQ, FT,
�.•
ZONE DRIVE APRON = 350 SQ. FT.
FLOOD \ ' X. PUBLIC SIDEWALK =_315__Sq. FT.
ZONE SOD450
TOTALS sq. FT.
17 O p��j AREA =_10440^37 SQ. FT.
C DRIVEWAY = 931 SQ. FT.
SIDEWALK =_34_5 SQ. FT.
Vq /O� ;\ SOD = 5846 SO. FT.
cr
\ACArAJ 'Sr O
\ 5 +
DESCRIPTION:
b PROPOSED:
LOT 21, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION LOWEST FLOOR ELEVATIONS:
PHASES 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 LIVING AREA: 101.00'
THROUGH 080, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA:
ELEVATIONS REFERENCED TO
CURVE RADIUS ARC CHORD BEARING DELTA NORTH AMERICAN VERTICAL
C13s 225.00' 63.56' 1 63.35' 1 N 62.07.32" w 1 16.11.06" DATUM OF 1988. MEAN SEA
C137 1 225.00 49.64 49.54 N 47'42 47 W 12'38 25 LEVEL= 00.00 FT.
C141 350.00 86.12 85.91 S 56'2918 E 1 14.05 55
APPARENT FLOOD HAZARD ZONE: "X&A" COMMUNITY PANEL NO. 12101C 0288 F EFFECTIVE DATE: 9/26/14
Project Number: Square Feet: 9325.55 t LENNAR HOMES
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE W F= WOOD FENCE
JOHN R.BEACH&ASSOCIATES,INC. Drawn By.
y SMS
_I_ SURVEYORS AND MAPPERS Checked By.
911 WEST ST. PETERSBURG DRIVE JRB
ONE OLDSMAR, FLORIDA 34677
WAY (813) 554-1276 FAX (813) 855-8370 Scale:1 30'
NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 10/8 18 JBS
THE ORIGINAL RAISED SEAL OF A FLORIDA AT DA E
LICENSED SURVEYOR AND MAPPER JOHN R. BEA
Revlslons: FLORIDA REG. L D SURVEYOR No. 2984 LB 4493
JEFF M. HARR
P URVEYOR & MAPPER No.71
Single Family Dwelling
Plan Review Comments
1: F.F.E. shall be a minimum of.8" above the road elevation and an engineered site plan.
.2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.-O.M. use permit. All 4 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8: All A.D.A. requirements shall be met.
9. No electric,plumbing,mechanical, or framing shall be covered without an.inspection and
approval first:
10. All Garages shall comply with section R302.6 of the F.B.C..(Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4:of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished_ grade. M13:08.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be 'installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R.308A of the F.B.C:
17. All means of egress are to.be-in accordance with R311 of the F.B.C.
18. "Green gypsum board"shall not be used as a backer in showers or tubs, R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker:
20. Carbon monoxide alarms will be required in new construction that uses fossil;burning heating
or appliances or an attached garage: They shall be,installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric:
22. All 2016 N.E.C: Codes will be enforced.
23. Tamper= Resistant keceptacles in accordance with 406.11 of the 2016 ME
.
24: In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure:
25. Blower door test and blown in insulation card shall be provided before C.O.
26 A copy of the Merky eacls shall be with permit at all titnes
2 Z Copy.of findl insulation-report shall be:proWded with permit before. !!4
28. No fence,.pool 6r screen enclosure is.issued with this permit.
F.F.E.-Finished Floor.Elevation
F.B.C-Florida Building Code 6a'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016)
Lennar Homes 35933 Saddle Palm Way 3,406 Sqft
ou
SQ. FEET PRICE
MAIN OR LIVING: 3,406 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 383,685.90
FEE SHEET $ 1,960.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 2,079.20
ELECTRICAL: $ 441.00
PLUMBING: $ 294.00
MECHANICAL: $ 205.80
SUB-TOTAL $ 3,020.00
Public Fee 1%
` TOTAL $ 3,020.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
I
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 3,573.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,628.00
100.0% $ 7,628.00
1.0% $ 76.28
TOTAL: $ 7,704.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 15,6-79.19