HomeMy WebLinkAbout19-20740 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20740
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20740 Issued. 1/30/2019 Address: 35965 SADDLE PALM WAY
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 447,220.50 Total Fees: 16,255.19 Subdivision: SILVERADO
Amount Paid: 16,255.19 Date Paid: 1/30/2019 Parcel Number: 04-26-21-0080-00500-0170
CONTRACTOR INFORMATION -OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,970 SQ FT
APPLICATION FEES
BUILDING FEE 2,400.60 ELECTRICAL FEE 513.00 PLUMBING FEE 342.00
MECHANICAL FEE 239.40 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00
SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
Inspections Required
F OTER 2 D ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPEC77ON FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance'
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
ONTRAC RS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
PASCO COUNTY, FLORIDA
Permit No. Z d 1 1I6
Date Permitted -2 -l
Builder Name/Owner Name 4/t/4— 'e<f Control#' l
County Pap:el No. 0 ~7_1`D09p._b&T0d-617d SubDIV:
Address/Location •359 5 Sahll 16)
ClassificatioNType of Use 61 e 3 ?70 s
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: ,97a
Exempt ❑Yes [] No How Determined
Impact Fee Amount $. 3/631Z Zone No. TAZ:
SCHOOL IMPACT FEE -71605, 2-8
Account (0561 Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes Q No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
*� a
Zone TOTAL AMOUNT $ /0 9(j6
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility.Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By ` Checked By
i-
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Lennar Homes-35965 saddle palm way 3970 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 3,970 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER:
VALUATION $ 447,220.50
FEE SHEET $ 2,280.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 2,400.60
ELECTRICAL: $ 513.00
PLUMBING: $ 342.00
MECHANICAL: $ 239.40
SUB-TOTALI $ 3,495.00
TOTAL $ 3,495.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: na
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ , 553.35
SUB-TOTAL $ 4,048.35
PARK IMPACT FEES $ 769.56 I'
SIF'S: $ 7,728.00
100.0% $ 7,728.00
1.0% $ 77.28
TOTAL: $ 7,805.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 16,255.19
Lennar Homes 35965 Saddle Palm Way 3,970 Sqft
i
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 3,970 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 447,220.50
FEE SHEET $ 2,280.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 2,405.60
ELECTRICAL: $ 513.00
PLUMBING: $ 342.00
MECHANICAL: $ 239.40
SUB-TOTAL $ 3,500.00
Public Fee 1%
TOTAL $ 3,500.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
1 TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 4,053.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 15,654.19
PI,p HIGH �
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: eA 04,r 4�Y-yv
Date Received: A- 1 ) -e
Site: s3401,o �
Permit Type: Imo. , mil, ! � S �
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
i
This comment sheet shall be kept with the permit and/or plans.
Kalvin S zer—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
Single Family Dwelling
Plan Review.Comments
1. F.F.E. shall be a minimum of8" above-the road elevation and an engineered site plan.
2. Lots shall be:graded to comply with R401.3 of the F.B.C:
3. Compaction test required if-24 or more of fill;dirt is brought in at any one place.
4, Tie in survey required before pouring.concrete.
5. Driveways require a R.O.W. use permit. All 4.sides of driveway thru-the sidewalk shall-have
expansion material.
6. All setbacks shall be met.
7. All.property.markers shall be uncovered and marked at time of first inspection.
8. All.A.D.A. requirements shall be met.
9. No electric,plumbing, mechanical; or framing shall be covered without an inspection and
approval first: .
10. All:Garages.shall comply with section R302.6 of the F.B.C.-(Fire-Separation).
I L Appliances shall not be installed in a location where subject to mechanical damage:unless
protected by approved barriers. M303.4.of the F.B.0
12. Water:heaters shall comply with section.P607.3 of the F.B.C.
13. Foundation supports_for A/C units shall be raised at least 3" above finished grade. M13.08.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be 'installed in accordance with R313.1 ofahe F.B.C.
16. All glazing requirements are to be'in accordance with R308:4.of the E.B.C.
17. All means-of egress are to be' in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4:2 F.B.C.
19. Combination-t
. .
ype AFCI breakers are.required at all locations requiring.an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil=burning heating.
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.-
21.All plumbing,mechanical, and electrical shall be-separate from unit to:unit. This includes all
underground plumbing and electric.
22. All 2016 N.E.Q. Codes will be enforced.
23. Tahiper= Resistant Receptacles' in accordance with 406.11;of the 2016 N.E:C
24. In accordance with.the Land Development Code, Lois shall be sodded before final.at least 10. j
feet around the structure:
25. Blower door test shall be provided before.C.O.
26.. A cony of the energy cads shall be with permit at all times
27. Cbi of rind[insulation report shall be.:Provided with:Permit before:rinaL
28:No fence;.poo[or screen enclosure is issued with-this permik
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code Oh Edition
R.O:W. .-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016)
\ / Fax-813-780-0021
sl3aso-ao2a City Of Zephyrhills Permit Application
Building Department
_k(n
Date Received Phone Contact for Permitting _ 813 363 __ 2891
1 1 1 1 ! I I 1 1 1 1 1- -1
Owner's Name Lennar Homes,LLC Owner Phone Number 13.574.5700
$......
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number �—
Fee Simple Titleholder Name N/A Owner Phone Number
Fee SimpW,Titleholder Address N/A
JOB ADDRESS 35965 Saddle Palm Way I LOT# 0170
SUBDIVISION Siiverado Ranch Subdivision Ph 6,8,9A PARCEL ID# 04-26-21-0080-00500-0170
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED lI✓II NEW CONSTR 8 ADD/ALT SIGN Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR 0 COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME, STEEL 0
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 4093 1 SQ FOOTAGE 3255 HEIGHT 2 Story
"rrl'r-t-r'ra—r-r'
BUILDING e2 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ AMP SERVICE ® PROGRESS ENERGY W.R.E.C.
� • r � ,
OPLUMBiNG 1$ �
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
[ GAS ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS � FLOOD ZONE AREA DYES DO
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4600 W.Cypress St.Ste,20 , ampa,FL 336 CGC1518166
License#
ELECTRICIANF COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN L=N
Address 1034 Skipper Road,Tampa, FL 33913 License# I EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating & AC, InC
SIGNATURE REGISTERED Y/ N FEE CURREN Ly/N
Address P.O. Box 5308, Bayone , FL 34674-53 License# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc
SIGNATURE REGI TERED Y/ N FEE CURREN Y/N
or
Address P.O. Box 5308, Bayonet,K 34674- License# I CAC058062
OTHER COMPANY C Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4211 Shoal Line Blvd, SpriqVHill, FL 34607 License# 1 CCC057991
IIIIIIIIItllllllilllllllllll.IIIIIItllllllllllllllllillllllitlllllll
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
�� I l l 1 1 1 :.■ I 1... .••:
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation.of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to'-exceed ninety (90) days and will demonstrate
justifiable cause for the extension. if work ceases for ninety(90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S. 117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)be me this Subscribed and savor ffirmed)before me this
I-JeP-10 by Ashlee Callahan »say re b ee Callahan
Who is/are personally known tr Who is/are p ally known to me or o o
identification. entification.
Notary Public Notary Public
11<
Commission No. FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
frPlB39�i't1r1'rrryrrla'r,4�1!tNOi}�]�Ft1�11
r
`A' _.
00.
•�'4�r, •• I _ - _ - ` fig' g��t 93: !'
10S.50
-:fit LC?T.26 ' 0 : 71'pt, B.
r 5 ` t
s y ppf04:$. ` .��4 -, 00.0 �j"� 0 { ?C9sas'. ,~ss:n p(3. 0
e0 Ef w 10120
�`gy�qp 00' .",• ar `' °� y'• ?C4�4f ;
9g?xr3t '¢ 131 L1 99,• 21
000 ` - *NO
� 6 ) 4) ,. .
�\ 1aLOrOryy�B` t�o� ,r TYPE g" +,
t ' pAD:zNO
fD6.� drryy�`((Tykpp' ;i ti i 0`� •; o .D.• + n , • `, `; {j,
20
fi
h (oo AC �,,�� ' S ti . `� F�sfo.r•3a•'` ,�$� � ` `'�,,. :., a ,, t,� � �
r'.
gQ �.. PAD�f ; a vu
IN
0Q� ` �Oi. 4 6�j
Ado: s„3' PF_1 D f:30 .9�60• ` 0 ' LVI 1.8;t g' ,g1 ;l , ;• �
r !
\ � \ �, (S :.K" _ .O tt{�.1 .\� •i��� ��t'V ,,•,+ IVV�.A�'7',\ ,}, f � �7 '��'tv 1 �r�'�+
y. •D .fir f {,,, \',,� 3��`, 4 ' lop -';; " Ft11:8Q �9+1` `g ',pq ` ni 7• �s9 �•,, 'I�9
.//��.���. t� �..• ` ' \�,.y��;{'." V�,�,,t �j � ` \ � ,/ ['/♦�� A -._r� � ,t. - � `>• 4�1�1 , � G�, -
-.(. ��+• •y.l'S\f \� l^'- 64,a\ ``\� .7\ ` `t �• ( • � '-.,1 '. ��V� ��, ,i° l � li, `` ( � i�"� `s` +M
'♦ tF/ t �. V` , _ ���n, ,gyp
FF Y Lul g
cf , ! tiC� �\���`, ,.� �\ " t�\ `, •�' �2 L�f42:Q ', g��g `',s t � R t�
t s t0 ` � •, ADS 10 i
.t//t `.+j: t/ f' t, `?,r* \ ` \'+ 't,1a- ,;,,,'\ `• \ \ k J PAS}, 0.1 �` '. , ,�,� �` .0', n.�(jE+ (y t .� .`
_ �' ' J ` 1 `, 1t\S�Ci•�'\l4 �,, i \ ` , 1}l'UpC.'`, ` 1 f � 10(�W� ❑ i /'1� `
A Lnl' 80
�` PAD—,100,4. .
0 85'lip . f0o 9 ', F�D102.1'0 Itt � 1� � t00. L0�90.80 �.
rA
i so\ t , •tot' •a fi� -//
\ , Is ` +/
St 7 h I tr
0
PASCO COUNTY
CONSTRUCTION SERVICES
PASC BUILDING 8731'Citizeri.s Drive Date:4/30/2019
COUNTY F�t�Ri A Suite 230
Oi,EN SN%crs.VIBMNTPLACUS. New Port Richey, FL 34654
.727-847-8126
NOT A PERMF
Rec6ipt#: 1852441
FEE DESCRIPTION ACCOUNT bblit UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-32901 0 1.00 1453453 $45.00. $415.0.0 '18.52447 4/30/19
Waste Sindle Family
TOTALS: s4s.00 $46.00
Receipt# Paid By Check i CC Auth# Cashier ID Workstation Receipt Date All Paid
1-852447 Check 61212946 MLARNOLD BCQCP59W 04/8Ci/2019 $45.00
Total.Payments: $46.00
Pa or Address Phone
Lennar Homes,LLC
Comments:
35965 Saddle Palm Way
,While you will be paying your bill with Pasco 666tV Building construction Services,the full amount of the credit caM or e-check fees,'NOT shown ab6v6,Is
coficted by First Billing payment services:
MyR6pqrts/repoits//`PASbOPR-OD/PAS.O,O/ReceiptM_V7.rpt 4/30/2019 Page 1 of
}
CITY OF / / / / BUILDING
ZEPHYRHILLS DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT REMOVE
ADDRESS n TE PERMIT f
The following odditio s or corrections shall be made before the job
THIS JOB HAS NOT BEEN COMPLETED. will be accepte .
14
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample time to approve _
the installation:
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0517
Street: 35965 Saddle Palm Way Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,'AH: 1st Floor 6 376
a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.30
b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.58 40.00 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.355 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090
Total Proposed Modified Loads: 98.94 PASS
Total Baseline Loads: 98.98
hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this Q . Grp
Code. calculation indicates compliancew
/. with the Florida Energy Code. +.'
PREPARED BY: �aVe ,�lol�rGG� Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908 *< °•-.. *.
hereby certify that this building,as designed, is in complian a Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL: i
DATE: OCT 16 MilliDATE:
- Compliance requires certification by the air handler nit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
7/25/2018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5
i
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0517
Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes
Street: 35965 Saddle Palm Way Permit office: City of ZephyrhillS
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 376
a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.58 40.00 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.355 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090
Total Proposed Modified Loads: 98.94 PASS
Total Baseline Loads: 98.98
I hereby certify that the plans and specifications covered by Review of the plans and kxElST�
this calculation are in compliance with the Florida Energy specifications covered b this r
P 9Y P Y
Code. calculation indicates compliance
with the Florida Energy Code. `rrrrr ''"Ada"1
PREPARED BY: _ / /
Dave >���G Before construction is completed 'r� U
DATE: this building will be inspected for
compliance with Section 553.908 * =- �_•;< *.
hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code. C'Q
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5
i
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
I
Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0517
Street: 35965 Saddle Palm Way Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes ,jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul, Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH: 1st Floor 6 376
a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.30
b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl, U=0.58 40.00 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.355 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 98.94
Glass/Floor Area: 0.090 PASS
Total Baseline Loads: 98.98
I hereby certify that the plans and specifications covered by Review of the plans and .Tk1E S, ? '"..
this calculation are in compliance with the Florida Energy specifications covered b this
P 9Y P Y
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Dave Aloltich Before construction is completed :
DATE: this building will be inspected for j" - v
compliance with Section 553.908
hereby certify that this building,as designed, is in compliance Florida Statutes. : "
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-201-7 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 3246A sf ADS Carrier Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 3255 Lot#
Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 90 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
.CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1880 16168
2 Block2 1375 11000
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor 1880 16168 Yes 2 1 1 Yes Yes Yes
2 2nd Floor 1375 11000 No 4 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 71 ft 0 1880 ft2 0.3 0 0.7
2 Floor over Garage 2nd Floor ____ 679 ftz 11 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2772 ftZ 0 ftZ Medium 0.85 No- 0.9 No 0 22.6
ATTIC
I
I
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC �
I
1 Full attic Vented 300 2559 ft' N N
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 5
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1375 ft2 0.11 Wood
2 Under Attic(Vented) 1 st Floor 30 Blown 1184 ft2 0.11 Wood
3 Knee Wall(Vented) 2nd Floor 30 Batt 84 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below()rnt To Wall T-vpe
R-Vahle Ft In Ft In Area R-\/,qf,le Fraction Ahnr Grade%
1 N=>E Exterior Concrete Block-Int Insul 1 st Floor 4.0999 20 9 8 8 179.8 ft2 0 0.600000 0
2 E=>S Exterior Concrete Block-Int Insul 1 st Floor 4.0999 56 8 8 485.3 ft2 0 0.600000 0
3 S=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 43 8 8 372.7 ft2 0 0.600000 0
4 S=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 7 8 8 60.7 ft2 0 0.600000 0
5 W=>N Exterior Concrete Block-Int Insul 1 st Floor 4.0999 27 10 8 8 241.2 ft2 0 0.600000 0
_6 N=>E Garage Frame-Wood 1st Floor 11 28 8 8 8 248.4 ft2 0.23 0.01 0
7 W=>N Garage Frame-Wood 1st Floor 11 25 8 8 8 222.4 ft2 0.23 0.01 0
8 N=>E Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft2 0.23 0.600000 0
9 S=>W Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft2 0.23 0.600000 0
10 E=>S Exterior Frame-Wood 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0
11 W=>N Exterior Frame-Wood 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In i
1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2
2 N=>E Wood 1 st Floor None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp , Area Depth Separation Int Shade Screening
1 N=>E 1 Metal Low-E Double Yes 0.56 0.3 N 32.0 ft2 3 ft 0 in 0 ft 6 in Drapes/blinds None
2 E=>S 2 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
3 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
4 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
5 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 9.3 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
6 S=>W 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 2 ft 0 in 1 ft 3 in Drapes/blinds None
7 N=>E 8 Metal Law-E Double Yes 0.56 0.3 N 32.0 ft2 1 ft 0 in 3 ft 5 in Drapes/blinds None
8 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
9 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 21.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
10 E=>S 10 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
11 W=>N 11 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
I
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-201.7 INPUT SUMMARY CHECKLIST REPORT
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 679 ft2 679 ft2 56 ft 8.6 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA E LA ACH ACH 50
P 4
1 Wholehouse Proposed ACH(50) .000318 2716.8 149.15 280.5 .2954 6
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 1 sys#1
2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1
2 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 376 ft2 1 st Floor 94 ft2 Proposed Qn 1st Floor —cfm 56.4 cfm 0.03 0.50 1 1
2 Attic 6 275 ft2 2nd Floor 68.75 ft Proposed Qn 2nd Floor --cfm 41.3 cfm 0.03 0.50 2 2
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5
1
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb [ ]Mar A r j
Ma rl
Jun rl
Jul rl
Au rl
Se Oct [ ]Nov Dec
Heatin f X Jan Feb [X]Mar E Apr f May Jun Jul AuSep f Oct [X]Nov H
Dec
Ventin [ Jan Feb X Mar [X A r [ May Jun Jul Aug Se [X Oct ki Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
`MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftZ 0 ft 0.3 1 st Floor
Default 8 Ibs/s .ft. 0 ftZ 0 ft 0.3 2nd Floor
Name: Signature:
Rating Compant: Date:
i
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 5
1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts,location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b)Return ducts R 6.0
c)AHU location varies
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 5 13. Cooling system: Capacity 48.0
a)Split system SEER 15.5
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 3255 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.555
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.315 14. Heating system: Capacity 48.0
c)Area 7c. 292.6 a)Split system heat pump' HSPF 9.0
b)Single package heat pump HSPF
8. Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised (R-value) 9b. 11.0 15.Water heating system
c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g) Other
1.Wood frame(Insulation R-value) 10131. 11.0
2.Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. 30.0 d) Multizone cooling credit j
d) Radiant barrier installed 11 d. No e)Multizone heating credit
f) Programmable thermostat Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or ex Ided) in this home before final inspection. Otherwise,a new EPL
display card will be completed based on i tailed code compliant features.
Builder Signature: Date: 09/18/18
Address of New Home: /65 Saddle Palm Wa City/FL Zip: . FL ZeFhyrhiRs,FL 33541
7/25/2018 1:10:50 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Job: 3246A sf ADS Carrier
Building Analysis Date: 9/18/2018
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
i
Project • •
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa Intl AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 38 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9
Dry bulb(°F) 32 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
FEW. LW
Component Btuh/ft2 Btuh % of load
Walls 4.8 8609 33.5 uas
Glazing 27.4 4320 16.8 nfiltration
Doors 22.7 450 1.7 wall
Ceilings 1.3 1524 5.9
Floors 3.1 5885 22.9
Infiltration 1.5 2914 11.3
Ducts 2029 7.9 FI°ors
Piping 0 0
Humidification 0 0 Glazing
Ventilation 0 0 Ceilings
otner
Adjustments 0
Total 25732 100.0
• •
Component Btuh/ft2 Btuh % of load
Walls 2.8 5010 24.9 Internal Gains
Glazing 51.8 8168 40.5 Walls Ducts
Doors 18.6 368 1.8
Ceilings 1.8 2190 10.9 Infiltration
Floors 0 0 0
Infiltration 0.3 656 3.3
Ducts 2068 10.3 Ceilings
Ventilation 0 0
Internal gains 1700 8.4 other
Blower 0 0
Adjustments 0
Total 20159 100.0 Glazing
Latent Cooling Load= 1748 Btuh
Overall U-value= 0.109 Btuh/ftz-°F
Data entries checked.
wrightsoft- 2018-Sep-18 07:14:10
•M*� ww - Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACCK ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
Job: 3246A sf ADS Carrier
Building Analysis Date: 911 812 01 8
i
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa Intl AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (OF) 38 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9
Dry bulb(°F) 32 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh % of load
Walls 3.7 4116 31.0 Ducts
Glazing 29.2 3867 29.2 Wall
Doors 0 0 01
Ceilings 1.2 1667 12.6 nriltration
Floors 2.0 9 0.1
Infiltration 1.5 1858 14.0 other
Ducts 1737 13.1
Piping 0 0 Ceilings
Humidification 0 0
Ventilation 0 0 Glazing
Adjustments 0
Total 13255 100.0
Component Btuh/ftz Btuh % of load
Walls 2.8 3100 17.6 Walls Intemal Gains
Glazing 50.1 6634 37.7
Doors 0 0 0
Ceilings 1.7 2395 13.6
Floors 0.8 4 0.0 ucts
Infiltration 0.3 418 2.4
Ducts 1789 10.2
Ventilation 0 0 Infiltration
Internal gains 3258 18.5 other
Blower 0 0 Glazing Ceilings
Adjustments 0
Total 1 1175981 100.0
Latent Cooling Load= 3263 Btuh
Overall U-value= 0.097 Btuh/ftz-°F
Data entries checked.
-F- wr1ghtsoft- 2018-Sep-18 07:14:10
.�- •�•h -w���• Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
'� ...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
Project Summary Job: 3246A sf ADS Carrier
J Date: 9/1812018
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Notes:
Design Information
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23703 Btuh Structure 18091 Btuh
Ducts 2029 Btuh Ducts 2068 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 25732 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 20159 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 1332 Btuh
Ducts 416 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 1880 1880 Equipment latent load 1748 Btuh
Volume(ft') 16486 16486
Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 21907 Btuh
Equiv.AVF(cfm) 70 36 Req. total capacity at 0.85 SHR 2.0 ton
Heating Equipment Summary I Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil F134CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47'F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.031 cfm/Btuh Air flow factor 0.040 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O j
Space thermostat Load sensible heat ratio 0.92
Capacity balance point= 35 OF
Backup:
Input= 7 kW, Output= 24093 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-tW- wrightsoft- 2018-Sep-18 07:14:10
Right-Suite®Universal 2018 18.0.16 RSU05714 Pagel
ACCK ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
,
Project Summary Job: 3246A sf ADS Carrier
1 •y Date: 9/18/2018
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
I
Project • •
For: Lennar Homes
Notes:
Design In • •
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11517 Btuh Structure 15809 Btuh
Ducts 1737 Btuh Ducts 1789 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 13255 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17598 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2899 Btuh
Ducts 364 Btuh
Central vent (0 cfm) 0 Btuh
Heating Coolingg (none)
Area(ft2) 1375 1315 Equipment latent load 3263 Btuh
Volume(ft3) 10998 10998
Air changes/hour 0.24 0.13 Equipment Total Load (Sen+Lat) 20861 Btuh
Equiv.AVF (cfm) 45 23 Req. total capacity at 0.85 SHR 1.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor, 0.060 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point= 18 OF
Backup:
Input=4 kW, Output= 13485 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Pk- wrightsoft- 2018-Sep-18 07:14:10
�� r^•• •w -*� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
Manual S Compliance Report Job: 3246A sf ADS CarrierDate: 9118/2018
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
i
Project • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 20159 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77.2°F Latent gain: 1748 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21907 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 101% of load
Latent capacity: 3600 Btuh 206% of load
Total capacity: 24000 Btuh 110% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 32.1 OF Heat loss: 25732 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 18859 Btuh 73% of load Capacity balance: 35 OF
Supplemental heat required: 6873 Btuh Economic balance: -99 OF
i
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 7.1 kW 94% of load Temp. rise: 50 OF
Meets all requirements of ACCA Manual S.
- wrightsoft- 2018-Sep-18 07:14:10
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACCK ...pment\3246 sf ADS template 2,2 ton Carrier.rup Cale=MJ8 Front Door faces:SW
Manual S Compliance Report Job: 3246A sf ADS Carrier
Date: 9/18/2018
upperfloor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 17598 Btuh Entering coil DB: 75.5°F
Outdoor design WB: 77.2°F Latent gain: 3263 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 20861 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 116% of load
Latent capacity: 3600 Btuh 110% of load
Total capacity: 24000 Btuh 115% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 32.1 OF Heat loss: 13255 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 18852 Btuh 142% of load Capacity balance: 18 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 4.0 kW 102% of load Temp. rise: 50 OF
Meets all requirements of ACCA Manual S.
t -Fk wrightsoft® 2018-Sep-18 07:14:10
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW