HomeMy WebLinkAbout19-20741 J CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20741
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION- LOCATION INFORMATION
Permit#:20741 Issued: 1/30/2019 Address: 35949 SADDLE PALM WAY
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 461,076.45 Total Fees: 16,360.19 Subdivision: SILVERADO
Amount Paid: 16,360.19 Date Paid: 1/30/2019 Parcel Number: 05-26-21-0080-00500-0190
'CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 15550 LIGHTWAVE DR#210
TAMPA, FL. 33607 CLEARWATER, FL. 33760
Phone: (813)574-5743 Lic: Phone: (727)479-1700
Work Desc: CONSTRUCT SINGLE FAMILY 4,093 SQ FT
APPLICATION FEES
BUILDING FEE 2,472.00 ELECTRICAL FEE 528.75 PLUMBING FEE 35150
MECHANICAL FEE 246.75 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,728.00
SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
Ins ections . e wired
FO TER 2ND ROUGH PLUMB IS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental'
entities such as water management, state agencies or federal agencies.
"Warning-to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements.to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance,
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O. I,
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO r
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i
Single Family Dwelling
Plan Review Comments
1: F.F.E. shall be a minimum of.8" above the-road elevation and an engineered site plan.
I Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test_required if 24" or more of fill dirt is brought in at any one place.
4, Tie in survey required before pouring.concrete.
5. Driveways require a.R.O,.W. use permit. All 4 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7.. All.property markers shall be uncovered and marked at time of first inspectio_n.
8. All A.D.A. requirements shall be met.
9. No:electric, plumbing,mechanical, or framing shall b,e covered without an.inspection-and
approval first.
10. All.Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage finless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.R.Q.
11 Foundation supports-for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return-air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with.R313..1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means:of egress are to be m accordance with R3 l l of the F.B.C.
- 18. "Green gypsum board"shall not be used 'ass-a backer.in.showers ortubs. R702.4:2:F.B,C.
19. Combination-type AFCI breakers are required of all locations requiring an AFCI.typ:e breaker: .
20. Carbon monoxide alarms will be required in new construction that uses fossil=burning heating.
or appliances or an attached garage. They shall-be installed in accordance with the F.H.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to:unit. This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced.
23. Taiiiper=Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 .
24. In accordance with the' Land Development Code, lots shall be sodded before final at-least 10
feet around the structure:
25. Blower door test shall be provided before C.O.
26.. A cony of the energy edels shall be with permit at all times.
27. Coyy of rndl insulation report shall beyrovided with:permit before. ina�
28:No fence,.pool:or screen enclosure is:issued with this permit
F.F.E.-Finished Floor Elevation .
F.B.C- Florida Building Code 6 h Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
City of Zephyrhills Permit Application Fax-0
Building Department
Date Received Phone Contact for Permitting 813 363 2891
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
|
JOB ADDRESS LOT# [0��90
SUBDIVISION Silverado Ranch Subdivision Ph 6,8,9A PAmCEL|o# 05-26-21-0080-00500-0190
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED mowoomom AOox\LT [---1 o}GN F—� F--1 DEMOLISH
P INSTALL R
REPAIR �
PROPOSED USE 0SFR [—� COMM F---1 CTHER
TYPE mFCONSTRUCTION D�U BLOCK �—1 FRAME F---1 OTEEL
��
DESCRIPTION OFWORK I Single Family Residence Pool/Screen Enclosure/Fence
BUILDING SIZE SQ FOOTAGE HEIGHT 12 Story �
U°� ABUiLo|w6
��_� VALUAT0NOF TOTAL CONSTRUCTION
�wy UELECTRICAL F?�—| PROGRE�GsNE�GY F--1 VV.R.E.C.
AMP SERVICE ---' ^--'
J—��
��P0�|NG
���
�_n
J,, ;MECHANICAL VALUATION OF MECHANICAL INSTALLATION
F--1 ��
G/�/ �� 3 ROOFING F—1 SPECIALTY F---1 OTHER
=� ___
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA � O
0U | �
�� ��F—�L
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED
14600
fOO
Address Licenuo#
ELECTRICIAN COMPANY n Electric, Inc.
SIGNATURE
REGISTERED _—___--- FEE CURREN
���� Ucense#
PLUMBERKayonet
m|G0ArumE
Address Lionnae# FCFC042998 �
MECHANICAL COMPANY Bayonet PlUmbincl, Heating & AC, Inc
SIGNATURE
Address Licenno#
OTHER COMPANY C Sterling Quality Roofing, Inc
SIGNATURE
Address 14211 Shoal Line Blvd, Sprineffl, FL 34607 Lioenao#
n n x x x u m x x m x o m n u x u x x N m u x mvn u u o x n m u x m o u n m u o m n n m w o n m u o m n n u m n x m x n n m n n m o n .
RESIDENTIAL Attach Sg Plot P|ens.;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(1O)working days after oubm.itto|date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed,
Sanitary Facilities&I clumpster,Site Work Permit for subdivisions/large projects
oD08MERC\N- Attach(2)complete sets of Building Plans plus a Life Safety-Page;(I-)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1clumpster.Site Work Permit for all new projects.All commercial requirements must meet-compliance
SIGN PERMIT Attach(4 sets n[Engineered P|anu
—°° �
PROPERTYSURVEYnaquinadforoUNEWoonutruction.
Fill out application completely.
Owner&Contractor sign back nf application,notarized
|f over$26Oo.a Notice of Commencement iorequired. (A/C upgrades over$7ann)
^^ Agent(for the contractor)or Power of Attorney(for the owner)would ba someone with notarized letter from owner amWoridngsame
'
OVER THE COUNTER PERMITTING (copy vfcontract required)
Remofs if shingles Gommno Service Upgrades A/C Fennoa(p}nV3umay/Footago)
Driveways-Not over Counter ifun public modwaya..needmROW
FNOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions. I
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONS IBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be,required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor BlocW' of this application for which they will be responsible, ' If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned underoteDda
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, changoof
use in existing buildings, or expansion of existing bui|dingo, as speodied|O Pasco County (][dinoDCg number 89-07 and
90-07. as onnended. The undersigned also underatanda, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving o "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power na|aooe, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ond|nannee.
CONSTRUCTION LIEN LAW(Chapter 713, Fyorida Statutes, smammended): |f valuation nf work ie$2.5DO.DDor more, |
certify that |, the appUnaUt, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. /f the applicant iosomeone
other than the "owner", | certify that | have obtained a copy of the above described document and promise in good faith to
deliver iito the"owDer' prior tocommencement.
CONTFACTOR'S/OWNER'SAFFYDAVUlF: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating constrVCtion, zoning' "and land development. Application is
honabv made to obtain a permit to do work and installation as indicated. | certify that no work or installation has
commenced prior to issuance of permit and that all work will be performed to meet standards of all |emvn regulating
construction, Countvand City codes, zoning regulations, and land development regulations in the jurisdiction. | also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
nly responsibility to identify what actions | must take tobeincompliance. Such agencies include but are not limited to:
- Department ofEnvironmental Protection-Cypress 8myheado, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management Diotdot-/VeUe' Cypress Bayheada' Wetland Areas, Altering
Watercourses.
- Army Corps ofEngineem-GeavmaUo. Docks, Navigable Waterways.
- Department of Health & Rehabilitative Gmrv|nee/Env|nonnnenta| Health Unit-WeUa, VVaatavvatmr Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authohtv-Runvvays.
| understand that the following restrictions apply bo the use offill:
- Use of fill io not-allowed in Flood Zone"Vp unless expressly permitted.
- If the fill nnoteha| is to be used in Hood Zone "A', it is understood that a drainage plan addressing a
"nonnpanneting volume" will be submitted at time of permitting which is prepared by o professional engineer
' licensed by the State ofFlorida.
- |f-thefiU material is to be used in Flood Zone "A" in connection with e permitted building using stem wall
construction, | certify that fill will be used only to f||| the area within the stem wall.
' If fill nngboho| in to be used in any area, | madjfv that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent propartige, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for |ohe |egS than one (1)
acre which are elevated by fill, an engineered drainage plan !orequired.
|f | om the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit phor.ho commencing construction. | understand that a separate permit may basequinad for electrical vvork,
p|Unnb|Og, ai8Ae, vveUa, pVoie, air conditioning, goo, or other installations not specifically included in the application. A
permit issued shall be construed to be o license to proceed with the work and not as*authority to violate, manom|, o|tar, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in p|aOs, construction or violations of any codes. Every permit issued shall become invalid
VO|ema the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work.is commenced. An extension
may be naquesbad, in writing, from the Building Dfhoio| fore period not to exceed n|nmb/ (00) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned.
WARNING TO OWNER YOUR FAILURE TO RECORD ANOTICE OF COMMENCEMENT
PAYING TWICE FOKIMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE CW'COMMENCEMENT.
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed me this Subscribed-and swppno(or affirmed)before me this
Who is/are personally known to moror ihave pFeduGed Who is/are personally known to me or'a........
as identification.- -as identification.
C\, Notary Public Notary Public
Commission No. FF98537 Commission No. PF98537
I%ismuM.Holleran Eho aM.Hn8eruo
Name of Notary tvped,printed or stamped Name of Notary typed,printed or stamped
MW
__
PASCO COUNTY, FLORIDA
Permit No. T�
Date Permitted �Z
Builder Name/Owner Name i f An!Gr Control#` .
County Panel No.
Address/Location 3 al a
Classhlcation/ ype of Use d? fe rZt
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 6 U _
Exempt ❑Yes [] No How Determined
Impact Fee Amount $.IS/ �J?2 Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ 7�BOA• `�
(057) Mobile Home
(056) Other Residential
123) Collection Fee
Exempt �Yes Q No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT
Exempt []Yes ' No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility.Account Facility Credit Facility Total
Exempt ❑Yes ❑ No How Determined Total Amoun "--
RESOURCE FEE , ERU
TOTAL AMOUNT
r
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for some.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Lennar Homes-35949 saddle palm way 4093 sq ft
Column
p SQ. FEET PRICE
MAIN OR LIVING: 4,093 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 461,076.45
FEE SHEET $ 2,350.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 2,472.00
ELECTRICAL: $ 528.75
PLUMBING: $ 352.50
MECHANICAL: $ 246.75
SUB-TOTAL $ 3,600.00
TOTAL $ 3,600.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: na
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
1 FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 4,153.35
PARK IMPACT FEES $ 769.56
1 SIPS: $ 7,728.00
100.0% $ 7,728.00
1.0% $ 77.28
TOTAL: $ 7,805.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
1 TOTAL: $ 16,360.19
1
Lennar Homes 35949 Saddle Palm Way 4,093 Sgft it
Column
SQ. FEET PRICE
MAIN OR LIVING: 4,093 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 461,076.45
FEE SHEET $ 2,350.00
ADDRESS $ 40.00
DRIVEWAYJ $ 40.00
BUILDING: $ 2,477.00
ELECTRICAL: $ 528.75
PLUMBING: $ 352.50
MECHANICAL: $ 246.75
SUB-TOTAL $ 3,605.00
Public Fee 1%
TOTAL $ 3,605.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
I
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
I
SUB-TOTAL $ 4,158.35
PARK IMPACT FEES $ 769.56
I
SIF'S: $ 7,628.00
100.0% $ 7,628.00
1.0% $ 76.28
TOTAL: $ 7,704.28
T 1 F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 16,264.19
AMILTON
ENGINEERING 6 SURVEYING. INC.
i
February Brd 2018
Mr.Bill Burgess
City of Zephyrhills
5335 8th Street
Zephyrhilis,FL 33542
Phone:813.780.0006
Fax: 813.780.0005
RE: LOMR-F Silverado-:Phase 6,8,-&9A(Plat Book 75,Pages 75-80)
Lots 17-16 Block 6 and Lots 14&19-17 Block 5
Dear Mr.Burgess:
Enclosed is a copy of the application and associated data necessary for the review and signing of the
Community Acknowledgement Form that accompanies the LOMR application to FEMA.Please return one
of the copies of the Community Acknowledgement Form signed for submittal to FEMA.
Enclosed•are the following items for the above project:
1. Property Information Form
2. Elevation Form .
3. Recorded Plat
4. Current Effective FIRM with Lots plotted.
S. Signed./sealed metes&bounds descriptions for Lots 24-26,Block 5&Lots 28,19,25;26 Block 6
6. 2 Coples of the Community Acknowledgement Form(Please return one)
if you have any questions or need additional information please:contact me at one of the contact
numbers below.
Sincer
i
i
Ric ack,P. c
Vice President
Hamilton Engineering&Surveying,Inc
Office Phone:813-250-3535 extension 111
Fax:813-250-3636 TAmo OFFICE
3A09 W:Lee mon Sheet
Tampa FL 33dW-1433.
Email:RichB@hamiltonengineering.us p•813.250.3535
f.8.13.250.3636
ORLANDO,OFFICE
775 Womer l.we
Orlando.FL 32803
p.813-25D-3535
W W WMAMILTONENGINEERING:US
Y
10
Y
a1 p LOT z � ,S
„� Pq '�.., tU.
rri
;Xx.,
' 4
t"., ./. ` gg�' F�7 ifJ` , J J _ li`` a ,` � Q `` •.. •. 9 `, ..'�'., i t
J, r' - - `• ` g�LOT $1 `• . �1t�S. •. ♦ `tc$• ~y
1. PF-10.5 '44 ` 'rX99 r '- ; �'pq .,w ` ,it' :, +, 'g�"J• ` • `, ``.
LOT 2s 0 2f �s �-- r00:8 ♦ -,.,`7'. .� • . `, 1� • .
tot. f h'p g '•r10 (3. 1� �, ti C94` 9g.t9 87
xtQ� o' {. ��p.05 o FF�ial.00
t ` ' - t
r'9 .4299'` 21
OF 10 •6Q 6 .9 - p A�0=1�3a3 l
Ll7T �- ,x Q PE
PA
TrP /,
41 , . ; � � rah ` 'tit,. �'` �►
,- V
DOT2o O `., • l .* ''`' +`5,t 4 . g2�*
(j_
J.
.r 4�p g. ' 0,07
..5 �,+"� v �+',:� s` a'wj,�; - 1,,♦j� • , ''. ♦ st ♦+9�`
...... _1 F� 104.9Q \,'. '' ,"''7 ` J 1�g*.;., '"`� '° ,`' o fj
c ;
mt:rO7.8
1 yQi �.: ♦♦
�a 3 LOT r ti< '` FF $ ' $
2
lb z' Pqp_ FF_' 0 �.t -'✓ LO g .0 • . `. ,
9 te as"3 ° o so ?� q�
Lo 0-1 01.
o� ] ` g'
a1,
to
om , , ` F "tt1.80 PA QT �7 csolg
�+
'LOT ', 101.0 ' .,,� ,'� , • . 4 .
c1y r• l i , 4
' Py. g i
fA.6 ,g `1
0 00' % �
pAD�1 t
.� +. ♦,+
Tw
SKETCH .ONLY SEC. 05 TWP. 26 S, RNG. 21 E.
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 19, BLO�K 5 BEARING BASIS:
SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02*35'32" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
ON LOT AREA CALCULATIONS N MAY BE DISCLOSED BY A FULL AND ACCURATE
TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
PRSrUMINARY DFZAWING*. LOT _15_q3_-91_SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
LIVING AREA =_AQ_cL__SQ. FT.
THIS PLAN IS FOR PERMITTING PURPOSES ENTRY = 159--SQ. FT. tn UNDERGROUND FOOTER, STEM WALL, AND
ONLY, NOT FOR CONSTRUCTION. VERIFY GARAGE = 679 —SQ. FT. 11 UNDERGROUND UTILITIES ARE NOT LOCATED OR
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. COVERED LANAI =_3Z&_::_SQ. FT. SHOWN.
PA110 =-.N4A SO. FT.
LEGEND: POOL AREA = NL&--SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
PROPOSED DRAINAGE FLOW CONC. DRIVE = 873—SQ. FT. NOTES TAKE PREFERENCE.
(00.00) PROPOSED GRADE A/C & CONC PAD = 25 SQ FT
E-00.00 EXISTING GRADE PRIVATE SIDEWALK ===§Q: FT: DESCRIPTION NOT CONTAINING PLAT BOOK AND
IMPERVIOUS = 48___% PAGE INDICATES THAT PLAT IS IN
= 3643 _SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO
NOTES: SOD = 3911 $0. FT. CHANGE AND/OR REVISION.
LOT GRADING TYPE = B OFF LOT AREA CALCULATIONS
PROPOSED PAD ELEVATION 100.6' RIGHT OF WAY = 1169.64 So. FT. CERTAIN DATA SHOWN HEREON BASED ON
FRONT SETBACK = 20' DRIVE APRON = 356:::�_ §Q� FT. ENGINEERING PLANS PROVIDED BY CLIENT.
SIDE SETBACK 7.5' PUBLIC SIDEWALK FT. STRUCTURE TIES SHOWN HEREON DENOTES
REAR SETBACK 15' SOD = 495 -SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
TOTALS TO PROPERTY LINE.
AREA =-912-3.57-SQ. FT.
DRIVEWAY = 1223 SQ. FT. 10' UTILITY EASEMENT
SIDEWALK = 352L_SQ. FT.
L
SOD =_Ai0_5SQ. FT. FLOOD
ZONE
A'
TRACT E
FLOOD DRAINAGE AREA
LOT 20 ZONE
BLOCK 5 "A'
FLOOD
ZONE
C) �X.
9 0
FLOOD CL 5r 19
ZONE <1
�X. 11
41
04
06, 0
_N
10
LOT 19
BLOCK 5
N' ro A
b
(100,30
LOT 18
41.
6 C.) BLOCK 5
rp:\
099.71)
PROPOSED:
LOWEST FLOOR ELEVATIONS:
LIVING AREA: 101.30'
DESCRIPTION: GARAGE AREA:
ELEVATIONS REFERENCED TO
LOT 19, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION NORTH AMERICAN VERTICAL
PHASES 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 DATUM OF 1988. MEAN SEA
THROUGH 080, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
rAPPARENT FLOOD HAZARD ZONE: "X&A" COMMUNITY PANEL NO, 12101C 0288 F EFFECTIVE DATE: 09/26Z14
Project Number. ISquare Feet: 7553.93 LENNAR HOMES
LEGEND:
CC)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK. PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U/P= UTILIL( POLE, W/F= WOOD FENCE
Drown By.
JOHN R. BEACH&ASSOCIATES,INC. SMS
SURVEYORS AND MAPPERS Checked By.
t 911 WEST ST. PETERSBURG DRIVE JRB
ONE OLDSMAR, FLORIDA 34677 Scale:
WAY (813) 854-1276 FAX (813) 555-8370 1 V=30' It
NOT VALID WITHOUT THE SIGNATURE AND 10/12/18 JBS
THE ORIGINAL RAISED SEAL OF A FLORIDA eGNA E
) DATE
LICENSED SURVEYOR AND MAPPER
HN R.
JOO;17 EB H
I'D
Revisions: SKETCH 10/10/18 JBS FLORIDXA RIG. ILAND SURVEYOR No. 2984 fJ3
L
aJOEFF M. ,HAWLEY
__IONAL SURVEYOR & MAPPER No.7123
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3246B sf ADS Carrier VW Builder Name: Lennar Homes 0519
Street: 35949 Saddle Palm Way Permit Office: Q of Zephyrhills
- City,State,Zip: FL, Permit Number:'Lb 1
Owner: Lennar Homes Jurisdiction: 611 �
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 11.Du cctt c.N R= ft2
s R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 376
a. U-Factor: Dbl,U=0.33 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.21
b. U-Factor: Dbl,U=0.33 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.23 a.Central Unit 24.0 SEER:15.50
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.58 40.00 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.684 ft.
Area Weighted Average SHGC: 0.233 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090
Total Proposed Modified Loads: 96.66 PASS
Total Baseline Loads: 98.98
I hereby certify that the plans and specifications covered by Review of the plans and a Ck .S 'q
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. �rra .!% •.;.a- �f' ";, O. `.i
PREPARED BY: Dave Aulic ` Before construction is completed ' ';t.
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed,is in com once Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: qq DATE:
- Compliance requires certificatio�ll� h it n ler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
1/8/2019 3:11 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R40k017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3246B sf ADS Carrier VW Builder Name: Lennar Homes 0519
Street: 35949 Saddle Palm Way Permit office: City of ZephyrhillS
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c. R= ft2
11.Duct
s R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH: 1st Floor 6 376
a. U-Factor: Dbl,U=0.33 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.21
b. U-Factor: Dbl, U=0.33 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.23 a.Central Unit 24.0 SEER:15.50
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl, U=0.58 40.00 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr, Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.684 ft.
Area Weighted Average SHGC: 0.233 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 96.66 PASS
Total Baseline Loads: 98.98
hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Dave Aupich Before construction is completed
DATE: this building will be inspected for compliance with Section 553.908 '>;
I herebycertify that this building,as designed, is in compliance Florida Statutes. s fi
fY 9� 9 P - �-
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICI L
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
1/8/2019 3:11 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3246B sf ADS Carrier VW Builder Name: Lennar Homes 0519
Street: 35949 Saddle Palm Way Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
10.Ceiling Types (2643.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 376
a. U-Factor: Dbl,U=0.33 133.33 ft2 , b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.21
b. U-Factor: Dbl,U=0.33 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.23 a.Central Unit 24.0 SEER:15.50
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl, U=0.58 40.00 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.684 ft.
Area Weighted Average SHGC: 0.233 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation,features
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 96.66 PASS
Total Baseline Loads: 98.98
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: DaVe AktiCh Before construction is completed .
DATE: this building will be inspected for p
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. oD`yyi~?fl
OWNER/AGENT: BUILDING Off I :�
DATE: DATE: JAW
- Compliance requires certification by the air handler unit manufacturer that the air handler closure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance wi h R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
1/8/2019 3:11 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5
r �
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 3246B sf ADS Carrier VW Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 3255 Lot#
Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Vinyl windows
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1880 16168
2 Block2 1375 11000
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor 1880 16168 Yes 2 1 1 Yes Yes Yes
I
2 2nd Floor 1375 11000 No 4 4 1 Yes 'Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 71 ft 0 1880 ft2 _-- 0.3 0 0.7
2 Floor over Garage 2nd Floor ---- ---- 679 ft2 11 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2772 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 2559 ft2 N N
1/8/2019 3:11 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1375 ft2 0.11 Wood
2 Under Attic(Vented) 1st Floor 30 Blown 1184 ft2 0.11 Wood
3 Knee Wall(Vented) 2nd Floor 30 Batt 84 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
R-Nlalue Ft In Ft In ArAn RA/able Fraction Ah,;nr Grade%,
1 N=>NE Exterior Concrete Block-Int Insul 1st Floor 4.0999 20 9 8 8 179.8 ft2 0 0.600000 0
2 E=>SE Exterior Concrete Block-Int Insul 1st Floor 4.0999 56 8 8 485.3 ft2 0 0.600000 0
3 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 43 8 8 372.7 ft2 0 0.600000 0
4 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 7 8 8 60.7 ft2 0 0.600000 0
5 W=>NW Exterior Concrete Block-Int Insul 1st Floor 4.0999 27 10 8 8 241.2 ft2 0 0.600000 0
6 N=>NE Garage Frame-Wood 1st Floor 11 28 8 8 8 248.4 ft2 0.23 0.01 0
_ 7 W=>NW Garage Frame-Wood 1 st Floor 11 25 8 8 8 222.4 ft2 0.23 0.01 0
8 N=>NE Exterior Frame-Woad 2nd Floor 11 50 8 400.0 ft2 0.23 0.600000 0
9 S=>SW Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft2 0.23 0.600000 0
10 E=>SE Exterior Frame-Woad 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0
11 W=>NW Exterior Frame-Woad 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ft2
2 N=>NE Wood 1st Floor None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 32.0 ft2 6 ft 0 in 0 ft 10 in Drapes/blinds None
2 E=>SE 2 Vinyl Law-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
3 S=>SW 3 Vinyl Law-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
4 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
5 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.3 ft2 1 ft 0 in 1 ft 3 in Drapesiblinds None
6 S=>SW 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 2 ft 0 in 1 ft 3 in Drapes/blinds None
7 N=>NE 8 Vinyl Low-E Double Yes 0.33 0.21 N 32.0 ft2 1 ft 0 in 3 ft 5 in Drapes/blinds None
8 N=>NE 8 Vinyl Low-E Double Yes 0.33 0.21 N 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
9 N=>NE 8 Vinyl Low-E Double Yes 0.33 0.21 N 21.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
10 E=>SE 10 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
11 W=>NW 11 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
I
1/8/2019 3:11 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 • INPUT SUMMARY CHECKLIST REPORT I.
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 679 ft2 679 ft2 56 ft 8.6 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000371 3169.6 174.01 327.25 .3446 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 1 sys#1
2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1
2 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
I
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 376 ft2 1st Floor 94 ft2 Proposed Qn 1st Floor —cfm 56.4 cfm 0.03 0.50 1 1
2 Attic 6 275 ft2 2nd Floor 68.75 ft Proposed Qn 2nd Floor —cfm 41.3 cfm 0.03 0.50 2 2
i
i
I
1/8/2019 3:11 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
I
Programable Thermostat:Y Ceiling Fans:
Cooling Jan Feb Mar A r May X Jun X Jul rj Au Se Oct HX
Nov Dec
Heating Jan Feb X1 Mar f Apr May Jun 4 Jul Au �Xj
Sep f Oct Nov H
Dec
Ventin Jan Feb X Mar [X A r [ Ma Jun [ Jul Aug Se [X Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 2nd Floor
Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 1st Floor
Name: Signature:
Rating Compant: Date:
i
1/8/2019 3:11 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location varies
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 5 13.Cooling system: Capacity 48.0
a)Split system SEER 15.5
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 3255 d) Room unit/PTAC EER
e)Other '
7.Windows,type and area .
a) U-factor:(weighted average) 7a. 0.364
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.233 14. Heating system: Capacity 48.0
c)Area 7c. 292.6 a)Split system heat pump HSPF 9.0
b)Single package heat pump HSPF
8. Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised(R-value) 9b. 11.0 15.Water heating system
c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. 11.0 e)Dedicated heat pump with tank EF
2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10B1. 11.0
2.Masonry(Insulation R-value) 10B2.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b) Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. 30.0 d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
i
I certify that this home has complied with the FloridaRoilding Code, Energy Conservation,through the above energy
saving features which will be installed(or exceedg<in this home before final inspection.Otherwise,a new EPL
display card will be completed based on instal code compliant features.
i
i
Builder Signature: Date: 01/15/19
Address of New Home: 449 Saddle Palm Way City/FL Zip: FL Ze12hyrhi11s.FL 33541
1/8/2019 3:12:09 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
I
Building Analysis Job: 3246B sf ADS CarrierVWI
g Y Date: 1/1512019
lower floor By: Dave Aldrich !
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa Intl AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 38 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9
Dry bulb(OF) 32 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh % of load
Walls 4.6 10317 39.7 Ducts
Glazing 18.9 2976 11.4 nfiltration
Doors 19.1 702 2.7
Ceilings 1.3 1524 5.9 wall
Floors 3.1 5885 22.6
Infiltration 1.7 2587 9.9
Ducts 2025 7.8 Floors
Piping 0 0
Humidification 0 0
Ventilation 0- 0 Glazing Do°Ceilings
Adjustments 0
Total 26017 100.0
Component Btuh/ftz Btuh % of load
Walls 2.4 5342 27.1 Internal Gains
Glazing 44.4 7014 35.6 Wall
Doors 15.6 573 2.9 Ducts
Ceilings 1.8 2190 11.1
Floors 0 0 0 Infiltration
Infiltration 0.4 582 3.0 j
Ducts 2069 10.5
Ventilation 0 0 Ceilings
Internal gains 1930 9.8
Blower 0 0 Doors
Adjustments 0
Total 19700 100.0 Glazing
!
Latent Cooling Load= 1801 Btuh
Overall U-value= 0.102 Btuh/ftz-OF
Data entries checked.
wrightsoft- 2019-Jan-15 12:47:04
^�*-• w - ^�� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...nt\3246 at ADS vw template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
I
BuildingAnalysis Job: 3246B sf ADS CarrierVW
Y Date: 1/1512019
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
I
Design Conditions
Location: Indoor: Heating Cooling
Tampa Intl AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 38 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9
Dry bulb(OF) 32 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh % of load
Walls 3.7 4116 32.0 Ducts
Glazing 17.8 2361 18.4
Doors 0 0 0 Wail
Ceilings 1.2 1667 13.0 nfiltration
Floors 1.1 785 6.1
Infiltration 1.7 2185 17.0
Ducts 1740 13.5
Piping 0 0 Floors
Humidification 0 0 Glazing
Ventilation 0 0 Ceilings
Adjustments 0
Total 12853 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.8 3100 17.4 Walls
Glazing 40.5 5367 30.2 Internal Gains
Doors 0 0 0
Ceilings 1.7 2395 13.5
Floors 0.4 300 1.7
Infiltration 0.4 492 2.8
Ducts 1787 10.1
Ventilation 0 0 Ducts
Internal gains 4330 24.4 Glazing
Blower 0 0 Infiltration
Adjustments 0
Total 17771 100.0 Ceilings
Latent Cooling Load= 3559 Btuh
Overall U-value= 0.071 Btuh/ft2-°F
Data entries checked.
-Fk-wrightsoft- 2019-Jan-15 12:47:04
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...nt\3246 sf ADS VW template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
r '
Project Summary Job: 3246B sf ADS Carrier VW
J ry Date: 111512019
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
i
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Notes: Vinyl windows
Design In • •
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23992 Btuh Structure 17631 Btuh
Ducts 2025 Btuh Ducts 2069 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 26017 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19700 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 1382 Btuh
Ducts 419 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1880 1880 Equipment latent load 1801 Btuh
Volume(ft') 16486 16486
Air changes/hour 0.23 0.12 Equipment Total Load (Sen+Lat) 21501 Btuh
Equiv.AVF(cfm) 62 32 Req. total capacity at 0.85 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 470F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.031 cfm/Btuh Air flow factor 0.041 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.92
Capacity balance point= 35 OF
Backup:
Input=7 kW, Output=24093 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsott� 2019-Jan-1512:47:04
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..nt\3246 sf ADS VW template 2,2 ton Carrienrup Calc=MJ8 Front Door faces:SW
I
Project Summary Job: 3246E sf ADS CaTervW
J ry Date: 1/15/2019
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
I
For: Lennar Homes
Notes: Vinyl windows
Design In • •
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11113 Btuh Structure 15984 Btuh
Ducts 1740 Btuh Ducts 1787 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12853 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17771 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3199 Btuh
Ducts 361 Btuh
Central vent(0 cfm) 0 Btuh
Heating Coolingg (none)
Area(ft') 1375 1375 Equipment latent load 3559 Btuh
Volume(ft') 10998 10998
Air changes/hour 0.29 0.15 Equipment Total Load (Sen+Lat) 21330 Btuh
Equiv.AVF(cfm) 52 27 Req. total capacity at 0.85 SHR 1.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 470F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.062 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.83
Capacity balance point= 17 OF
Backup:
Input=4 kW, Output= 13485 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
1 -F�11- wrightsoft 2019-Jan-15 12:47:04
_tt_ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
ACC ...nt\3246 sf ADS VW template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
i
Manual S Compliance Report Job: 3246B sf ADS Carrier VW
p p Date: 1/1512019
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 19700 Btuh _ Entering coil DB: 75.6°F
Outdoor design WB: 77.2°F Latent gain: 1801 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21501 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 104% of load
Latent capacity: 3600 Btuh 200% of load
Total capacity: 24000 Btuh 112% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 32.1°F Heat loss: 26017 ' Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASH
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L j
Actual airflow: 800 cfm
Output capacity: 18859 Btuh 72% of load Capacity balance: 35 °F I'
Supplemental heat required: 7158 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 7.1 kW 93% of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
t wrightsoft- 2019-Jan-1512:47:04
�� •w• ��ww--,�� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
-4CC ...nt\3246 sf ADS VW template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW
Manual S Compliance Report Job: 3246B sf ADSCarrierVW'
Date: 111512019
upperfloor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 17771 Btuh Entering coil DB: 75.5°F
Outdoor design WB: 77.2°F Latent gain: 3559 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21330 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturers Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 115% of load
Latent capacity: 3600 Btuh 101% of load
Total capacity: 24000 Btuh 113% of load SHR: 85%
i
Heating Equipment
Design Conditions
Outdoor design DB: 32.1°F Heat loss: 12853 Btuh Entering coil DB: 69.7'F
Indoor design DB: 70.0°F
Manufacturers Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 18852 Btuh 147% of load Capacity balance: 17 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 4.0 kW 105% of load Temp. rise: 50 'F
Meets all requirements of ACCA Manual S.
- wrightsoft® 2019-Jan-1512:47:04
�� <r•N ame ww Right-Suite®Universal 2018 18.0.16 RSU05714
Page 2
ACCK ...nt\3246 sf ADS VW template 2,2 ton Carrierrup Calc=MJ8 Front Door faces:SW