Loading...
HomeMy WebLinkAbout19-20744 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20744 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION " Permit#:20744 Issued: 1/30/2019 Address: 35941 SADDLE PALM WAY Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: . 364,873.35 Total Fees: 15,632.69 Subdivision: SILVERADO Amount Paid: 15,632.69 Date Paid: 1/30/2019 Parcel Number: 05-26-21-0080-00500-0200 CONTRACTOR INFORMATION OWNER.INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,239 SQ FT APPLICATION FEES BUILDING FEE 1,977.29 ELECTRICAL FEE 419.63 PLUMBING FEE 279.75 MECHANICAL FEE 195.83 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 1r . inspections Required FOOTER 2 D ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)WIth respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental. entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. I CONTRA ORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 0 10-t OU-UU/-V uity ot zephyrhills Permit.App'lica IOn Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting L 813 363 I- a I it it a a I 1 2 a a a [ M.5 709 Owner's Name Lennar Homes,LLC :Owner.Phone Number 81 .5 Owner's Address 1 4600 W.Cypress St.-Ste,200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 35941 Saddle Palm Way LOT# [0��OO SUBDIVISION Silverado Ranch Subdivision Ph 6,8,9A PARCEL ID# 05-26-21-0080-00500-0200 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR8 P ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR Q COMM OTHER TYPE OF CONSTRUCTION 10 BLOCK 0 FRAME 0 STEEL DESCRIPTION OF WORK I Single Family Residence I Pool/Screen Enclosure I Fence BUILDING SIZE I UIR'SF 3239 SQ FOOTAGE2443 HEIGHT 1 Story .............T I BUILDING V/ $I I Zqo VALUATION OF TOTAL CONSTRUCTION ZELECTRICAL 1$ AMP SERVICE FX_1 PROGRESS ENERGY W.R.E.C. OPLUMBING $ ZMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS PIr ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA E]YES Do BUILDER COMPANY Lenn Homes,LLC SIGNATURE A REGISTERED Y/ N FEE CURREN L_X._/N J Address 14600 W.Cypress St.Ste.200,Taijfa,FL 33607 1 License# I CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. CO SIGNATURE REGISTERED LYI_N FEE CURREN Address 11034 Skipper Road,Tampa''IfL 33613 License# FC1370705408 PLUMBER COMPANY Bayonet Plumbing, Heating & AC SIGNATURE REGISTERED Y/ N FEE CURREN LILN J Address P.O. Box 5308, Bayonet, FL 54674-5308 License# FCFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN L_yl N J Address P.O. Box 5308, Bayonet, FL 4674-5AB License# [CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N _J FEE CURREN I Y/N Address 14211 Shoal Line Blvd, Spring' Hill, FL 34607-7 License# I CCCO57991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. **"PROPERTY SURVEY required for all NEW construction. . . . . . . . . . .. . . . . . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2600,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned gsmunleereaponn|bi|hxformonnp|ianoeVYithany applicable ^ UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors bJ undertake work, they may ba required . be licensed in accordance with state and local regulations. If the contractor is not licensed as required by |aw, both the owner and contractor be cited for misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Lioensing Section at 727-847- 8009. Fudhg[nnons. if the owner has hired m contractor or oontnaotono, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that heia not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION I08PAC37OT{LlTlESIMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of Use in existing bUUdingo, or expansion of existing bui|diDga, as specified in Pasco County-Ordinance number8S-O7 and SO-07. aeamended. The undersigned also understands, that such fees, an may ba due, will be identified st the time of permitting. It is further understood that Transportation*Impact Fees and Resource Raonwary Fees must be paid prior to receiving a "certificate of occupancy" or final power release. !f the project doeenotinvo|veeoorbfivatecfom:upanoyor final power release, the fees must be paid prior to permit issuance. Furthennore, if Pasco County Water/Sewer Impact fees are due, they must bepaid / to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, FKmnida Statutes,asmmnemded): |f valuation of work|s$2.5DO.DOor more, | certify that |, the app|ioant, have been provided, with a copy of the "Florida Construction Lion Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. |f the applicant iosomeone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the"mmne/' prior bocommencement. CONTRACTOR'SNOWNERISAFFUDAVIT: | certify that all the information in this application io accurate and that all work will be done in compliance with all applicable laws regulating conmtrUct|on, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior.to issuance of permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning na0u\aUono. and land development regulations inthe jurisdiction. | also certify that i understand that the regulations of othergovernment agencies may apply to the intended work, and that it is' my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Env inonnnenta| Protection-Cypress Boyheodn, Wetland Areas and Environmentally Sensitive Lands, VVateo�Vmot�waherTreatment. - Southwest Florida VVohar Management D|otr|ct48eUn, Cypress Boyheada, Wetland Anoao` /\|bahng Watercourses. - Army Corps ofEngineero-GeaxvaUo. Docks, Navigable Waterways. - Department of Health & Rehabilitative 8arVinao/Env|nJO[nenta! Health Unit48AeUe, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authority-Runways. | understand that the following restrictions apply hz the use offill: - Use of fill io not allowed in Flood Zone Wr unless expressly permitted. - |f the fill material is to be used in Flood Zone "A', it is understood that o drainage plan addressing o ^mznnpanaaUnO volume" will be submitted at time of permitting which is prepared by a pnzhaesiVna| engineer |ioonood by the State ofFlorida. - If the fill material is to be used in Flood Zone "A° in connection with e permitted building using stem vvoU construction, | certify that fill will be used only to fill the area within the stem wall. - If fill nlatehol is to be used in any area. | uarUfv that use of such fill will not 'adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan iorequired. If| am the AGENT FOR THE OWNER, I promise in good faith t6inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. ( understand that o separate permit may be required for electrical vxork, p|UnnbiOg, signs, vve||o, pnV|e, air conditioniDg, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work d not as authorityto violate, cancel, alter, set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF, COMMENCEMENT MAY RESULT.IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND T B IN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEI BEFORE RECORDING YOUR NOTIC F COMMENCEMENT. OWNER OR AGENT �z CONTRACTOR Subscribed and sworn to(or affirmeoYbefore me this Subscribed and swopffo(or affirmed)before me this Who islare personally known to me or e4 Who is/are personally known to me or hasMay.ped., as identification. as identificaiion. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 ZDisouM.Holleran 8lissaM.Holleran ' �!r"•.._._�j----0�4- Sao j ry ___, p °1 Cad ••�� 2 Vv •,' '''l,e.nEr 24'0$ SDyw9 4 4 PAD; •S`' 0 .6 .. 0 2�' Tj`Pj g 7 g �� �,�. ,• rn Ob Q )Oce r. , r i' j ~` `� 7t90 OT '-' fV j •• `., �91 � , `+ , 1 `t�S• 9 b �D5.SQ a ' ;rx� aa,2, a0 -"r PAD-)00:6 �' $2''{g ' ` v PAD 12$ ;, ©� �s t� IN ? ,g YPF D 9 L 7• .. , 2p •,. ,4 ►,`r> 048 TY�P 2�jQ ��0PGFi FF*�5 `g9.17 ` ` 7 • t *""30 !' Y i �.DQ F x6d. x� 7.42 �p1 9 g „ - , -q PAD_f 21 1 27 0 - 1 fa? • `r: ry� TYPE PAD 106•Y + x9�:y ,� `' r `tiz� 1 �• '` •#'Or._. 'I'`•:",k ,` , 1 ,t `'1 t f ', •fir; .i.. � , , 1t 1a ok T �007 ACFF=�Of.30 ` �g ! f - g8 , �U�a . 006 rADaio4z ,ova sT TYPE a °T . • .� ag . F`107.0 L Apr ©�`� 1 � g�p ,6 .•y ,+ '� y'' Q 3 LOT t � `., > 9 at FF� f• ;c > PAD— 06-3 �` �= or. o sA s� o .G� LOT O T 18 AD:10 t PEg�J TYPE A Mbr ,tip � gp 70`, � el P61•80 g9,7` i D:381`�,PAQ LOT T 4 �g k4•'. t JO LPADx101.1 19 Yp01•Q � g' , ` ••.4,, ' ` / Ti"P��A � � '_ ,, p�t0 ',, 'i qo � g p '•.� `, F• Epp. FF; 6'•6 + , '`� � PAD Tw 6 ' FF�iQico , , PLOT PLAN SKETCH ONLY SEC. 05 TWP. 26 S, RNG. 21 E. NOT A BOUNDARY SURVEY LOT 20, BLOCK 5 BEARING BASIS: SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E PASCO COUNTY, FLORIDA. T 1 THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, PRELIMINARY DRAWING: EASEMENTS AND RESTRICTIONS OF RECORD. THIS PLAN IS FOR PERMITTING PURPOSES M ONLY, NOT FOR CONSTRUCTION. VERIFY UNDERGROUND FOOTER, STEM WALL, AND II UNDERGROUND UTILITIES ARE NOT LOCATED OR ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SHOWN. LEGEND: DO NOT SCALE THIS PRINT. DIMENSIONS AND -vnnr- = PROPOSED DRAINAGE FLOW Q NOTES TAKE PREFERENCE. (00.00) = PROPOSED GRADE E-00.00 = EXISTING GRADE DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO NOTES:LOT GRADING TYPE = B CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = 100.4' CERTAIN DATA SHOWN HEREON BASED ON FRONT SETBACK = 20' ENGINEERING PLANS PROVIDED BY CLIENT. SIDE SETBACK = 7.5' REAR SETBACK = 15' STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. ON LOT AREA CALCULATIONS LOT = 8607.75 _SO. FT. \ \ 10' UTILITY EASEMENT LIVING AREA = 2443_--SQ. FT. ENTRY =�141--SQ. FT. GARAGE = 655 _SQ. FT. COVERED LANAI =_NZ^—__SQ. FT. PATIO = 32 SQ. FT. POOL AREA =_NZA _SQ. FT. 3: C TRACT E CONC. DRIVE =_597 ---SQ. FT. a ; ,R� DRAINAGE AREA A/C & CONC PAD = 12 —SQ. FT, n:ry PRIVATE SIDEWALK --SQ. FT. IMPERVIOUS = 45 = 3909 ---SQ. FT. a SOD = 4699 -SQ. FT. LOT 21 O �S..• OFF LOT AREA CALCULATIONS BLOCK 5 RIGHT OF WAY =_1042.25 _SQ. FT. DRIVE APRON = 350 SQ. FT, o U+ PUBLIC SIDEWALK =_296 S0. FT. SOD = 39_6 SQ. FT. �� '�sr•, TOTALS <c. AREA =_96_50.00-SQ. FT. O S DRIVEWAY = 947 __SQ. FT. �� O. 90' SIDEWALK = 325 _-SQ, FT. h ��A i� A \�' q� ry�' (98.50') FLOOD SOD = 50095 —SQ. FT. 5 �`� c ZONE CABS AO Q•.. ,,NJ .\ A" FLOOD 9•Q `rc�� 1" i"\ ZONE 9CC(C� oC ��•.• ��!\ '•o LOT 20 0yTe•. _ BLOCK 5 _.._.. . ............................ FLOOD FLOOD —••—•• ZONE ZONE ° \. •w :'p X" X" \✓ y�h .��0 000. 2Sb �ro LOT 19 BLOCK 5 rA qg 0 a \� PROPOSED: DESCRIPTION: LOWEST FLOOR ELEVATIONS: LOT 20, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES LIVING AREA: 101.10' 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE GARAGE AREA: PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO NORTH AMERICAN VERTICAL CURVE RADIUS I ARC 1 CHORD BEARING I DELTA DATUM OF 1988. MEAN SEA C137 1 225.00 49.64 49.54 N 47'42 47 W 12'38 25 LEVEL= 00.00 FT.C142 350.00' 49.15' 49.11' S 45'24'57" E 08'02'46" APPARENT FLOOD HAZARD ZONE: "X&A" COMMUNITY PANEL NO. 12101C 0288 F EFFECTIVE DATE: 9/26/14 Project Number: Square Feet: 8607.75 t LENNAR HOMES LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINbHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE W F= WOOD FENCE JOHN R.®EACH&ASSOCIATES,INC. Drawn SMS By. SURVEYORS AND MAPPERS Checked By. 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 S1al: NOT VALID WITHOUT THE SIGNATURE AND Dote: PLOT PLAN 10/8/18 JBS /VZiw"✓ THE ORIGINAL RAISED SEAL OF A FLORIDA S AT ATE EA LICENSED SURVEYOR AND MAPPER JOHN R. I Revisions: FLORIDA REG. LA SURVEYOR No. 2984 LB 4493 JEFF M. HARTLEY RVEYOR & MAPPER No.7123 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2485B sf ADS Carrier VW Builder Name: Lennar Homes 0520 Street: 35941 Saddle Palm Way Permit office: City of ephyrhills City,State,Zip: ,FL, Permit Number: •2.,a-74 Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: .Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ft2 b.Frame-Wood,Adjacent R=11.0 312.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ft2 6. Conditioned floor area above grade(ft2) 2443 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(207.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390 a. U-Factor: Dbl,U=0.33 135.25 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 32.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.016 ft. Area Weighted Average SHGC: 0.244 14.Hot water systems 8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2443.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.085 Total Proposed Modified Loads: 68.64 PASS Total Baseline Loads: 69.68 I hereby certify that the plans and specifications covered by Review of the plans and .grA this calculation are in compliance with the Florida Energy specifications covered b this r P 9Y P Y Code. calculation indicates compliance '��/} ''' _'�•�, s+ Dave lol�tGl� with the Florida Energy Code. ` iini •� ;+.0. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in com 'once Florida Statutes. __ with the Florida Energy Code. OWNER/AGENT: BUILDING OFFJAIAL DATE: DATE: - Compliance requires certification by t air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 1/15/2019 12:55 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 ? 7 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2485B sf ADS Carrier VW Builder Name: Lennar Homes 0520 Street: 35941 Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit:Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ft' b.Frame-Wood,Adjacent R=11.0 312.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ft' 6. Conditioned floor area above grade(ft') 2443 b.N/A R= ft' Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(207.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390 a. U-Factor: Dbl,U=0.33 135.25 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 40.00 ft' 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 32.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.016 ft. Area Weighted Average SHGC: 0.244 14.Hot water systems 8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2443.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft' None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.085 Total Proposed Modified Loads: 68.64 PASS Total Baseline Loads: 69.68 I hereby certify that the plans and specifications covered by Review of the plans andk1E$Tr1` "... this calculation are in compliance with the Florida Energy specifications covered by this f. Code. calculation indicates compliance with the Florida Energy Code. Dave up cl� <� PREPARED BY: � Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. :: with the Florida Energy Code. Gpbt , OWNER/AGENT: BUILDING OFFICIA DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/15/2019 12:55 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2485B sf ADS Carrier VW Builder Name: Lennar Homes 0520 Street: 35941 Saddle Palm Way Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Flbrida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ftZ b.Frame-Wood,Adjacent R=11.0 312.00 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ftZ 6. Conditioned floor area above grade(ftZ) 2443 b.N/A R= ftZ Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(207.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390 a. U-Factor: Dbl, U=0.33 135.25 ftZ SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 40.00 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEERA5.50 c. U-Factor: Dbl,U=0.33 32.00 ftZ SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.016 ft. Area Weighted Average SHGC: 0.244 14.Hot water systems 8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2443.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.085 Total Proposed Modified Loads: 68.64 PASS Total Baseline Loads: 69.68 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered b this ' P 9Y P Y Code. calculation indicates compliance ;W with the Florida Energy Code. PREPARED BY: Dave Aulich Before construction is completed DATE: this building will be inspected for . compliance with Section 553.908 I hereby certify that this building, as designed,is in compliance Florida Statutes. k° with the Florida Energy Code. OWNER/AGENT: BUILDING OFFIC A DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 1/15/2019 12:55 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 24856 sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2443 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 315 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Vinyl windows CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 2443 19544 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2443 19544 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 144 ft 0 2443 ft2 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2646 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC' 1 Full attic Vented 300 2443 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type j 1 Under Attic(Vented) Main 30 Blown 2443 ft2 0.11 Wood I' 1/15/2019 12:55 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below RAlaille Ft In Et In Area R-Nlahle Fraction Absor 1 N=>NW Exterior Concrete Block-Int Insul Main 4.0999 20 ;8 160.0 ft2 0 0.6 0 2 E=>NE Exterior Concrete Block-Int Insul Main 4.0999 58 8 8 469.3 ft2 0 0.6 0 3 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 42 8 336.0 ft2 0 0.6 0 4 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 8 8 64.0 ft2 0 0.6 0 5 W=>SW Exterior Concrete Block-Int Insul Main 4.0999 47 4 8 378.7 ft2 0 0.6 0 6 N=>NW Garage Frame-Wood Main 11 29 8 232.0 ft2 0.23 0.01 0 7 W=>SW Garage Frame-Wood Main 11 10 8 80.0 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NW Insulated Main None .2 3 6 8 20 ft2 2 N=>NW Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NW 1 Vinyl Low-E Double Yes 0.33 0.21 N 32.0 ft2 6 ft 4 in 0 ft 6 in None None 2 E=>NE 2 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None 4 S=>SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in None None 5 S=>SE 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 2 ft 0 in 0 ft 6 in None None 6 W=>SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.0 ft2 1 ft 0 in 0 ft 10 in None None 7 S=>SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.3 ft2 1 ft 0 in 0 ft 10 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 655 ft2 655 ft2 60 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 2280.1 125.18 235.41 .2649 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1 1/15/2019 12:55 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1050 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 390 ft2 Attic 97 ft2 Proposed Qn Main —cfm 73.3 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma X Jun Jul rj Au �Xj Se [ ]Oct Nov ]Dec Heatin HJan Feb f Xj Mar f Apr I MaY Jun Jul Au Sep [ ]Oct H Nov X]Dec Ventin Jan Feb X Mar [X A r May Jun Jul Aug Se [X]Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(V11EH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS i Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 1 st Floor Default(8 Ibs/s .ft. 0 ft2 0 ft 0.3 2nd Floor Name: Signature: Rating Compant: Date: I 1/15/2019 12:55 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12.Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Attic 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 35.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2443 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.378 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.244 14. Heating system: Capacity 34.6 c)Area 7c. 207.3 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other - 8.50 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 I I. 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11 d. No e)Multizone heating credit f)Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise,a new EPL display card will be completed based on installed code compliant features. i I Builder Signature: Date: 01/15/19 Address of New Home: 35941 Saddle Palm Way City/FL Zip: , FL Zephyrhills,FL 33541 1/15/2019 12:56:10 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Buildin Anal SIS Job: 2485B sf ADS Carrier VW g Y Date: 1/15/2019 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes i Design Conditions Location: Indoor: Heating Cooling Tampa Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 38 16 Latitude: 280N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 Dry bulb(°F) 32 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces, 0 Component Btuh/ftZ Btuh % of load Walls 4.8 10056 31.2 Dui Glazing 19.7 4846 15.0 Wall Doors 19.0 721 2.2 nfilVat on Ceilings 1.2 2963 9.2 Floors 2.7 6616 20.5 Infiltration 2.1 3498 10.9 Ducts 3517 10.9 Floors Piping 0 0 Humidification 0 0 Glazing Ventilation 0 0 Doors Ceilings Adjustments 0 Total 32218 100.0 i Component Btuh/ftZ Btuh % of load Walls 2.5 5135 18.2 Walls Internal Gains Glazing 41.5 10218 36.2 Doors 15.5 589 2.1 Ceilings 1.7 4257 15.1 Ducts Floors 0 0 0 Infiltration 0.5 757 2.7 Ducts 3519 12.5 Infiltration 0 Ventilation 0 0 Internal gains 3750 13.3 Blower 0 0 Glazing Ceilings Adjustments 0 Doors j Total 28224 100.0 Latent Cooling Load= 3267 Btuh Overall U-value= 0.092 Btuh/ftZ-°F i Data entries checked. wr1ohtsoft- 2019-Jan-15 12:54:17 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..ipment%2485 sf ADS VW template 3ton Canier.rup Calc=MJ8 Front Door faces:SW Project Summary Job: 2485B sf ADS Carrier VW J Date: 1/15/2019 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Notes: Vinyl windows Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 38 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible.Cooling Equipment Load Sizing Structure 28700 Btuh Structure 24706 Btuh Ducts 3517 Btuh Ducts 3519 Btuh Central vent(0 dfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) '(none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32218 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28224`Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2537 Btuh Ducts 730 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2443 2443 Equipment latent load 3267. Btuh Volume(ft3) 22893 22893 Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 31491 Btuh Equiv.AVF (cfm) 84 42 Req. total capacity at 0.85 SHR 2.8 ton Heating Equipment Summary Cooling Equipment'Summary Make Carrier Make Carrier Trade PERFORMANCE 15 HP Trade PERFORMANCE 15 HP Model 25HBC537AO030 Cond 25HBC537AO030 AHRI ref 10487322 Coil FX4DNF037L AHRI ref 10487322 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 29750 Btuh Heating output 34600 Btuh @ 470F Latent cooling 5250 Btuh Temperature rise 26 OF Total cooling • 35000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 32 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft 2019-Jan-15 12:54:18 .� ^�^• ^w—��^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 �� ...ipment%2485 sf ADS VW template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW Job: 2485B sf ADS Carrier VW Manual S Compliance Report Date: 1/1512019 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.4°F Sensible gain: 28224 Btuh Entering coil DB: 75.5°F Outdoor design WB: 77.2°F Latent gain: 3267 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 31491 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29750 Btuh 105% of load Latent capacity: 5250 Btuh 161% of load Total capacity: 35000 Btuh 111% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 32.1 OF Heat loss: 32218 Btuh Entering coil DB:- 69.7°F Indoor design DB: 70.0°F i, Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 27314 Btuh 85% of load Capacity balance: 32 OF Supplemental heat required: 4904 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. -F- wrightsoft- 2019-Jan-15 12:54:18 �_ •w•���o•�-� -, Right-Suite®Universal 2018 18.0.16 RSU05714 �CA Page 1 ...ipment\2485 sf ADS VW template 3ton Carrier.rup Cale=MJ8 Front Door faces:SW /5z yS'72 o SZo. PASCO COUNTY cC BUILDING CONSTRUCTION SERVICES JlV �' y 8731 Citizens Drive Date:4/30/2019 COUNTY RoRin Suite 230 Qm:N Srncrs.1�inr to r ht u 45. New Port Richey, FL 34654 727-847-8126 N Receipt M 1852452 I� FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid .24503100-320010 1.00 1453462 $45.00 $45.00 1852452 4/30/19 Waste Single Family TOTALS: $46.00 $45.00 Receipt# Paid By Check# CC.Auth# Cashier ID Workstation Receipt Date Amt Paid 1852452 'Check 01212§49 MLARNOLD 9CCCP59W 04/30/2019 $45.00 Total Payments: $45.00 Payor Address Phone L'ennar Homes, LLC Commants: ^ ,A kA '35941 Saddle Palm Way `/v� While you will be paying your bill with Pasco County Building Construction Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptAA_V7.rpt 4/30/2019 Page 1 of 1 RASCO COUNTY, FLORIDA Permit No. 7 Date Permitted — Builder Name/Owner Name 1,�at t�c�►- l'CaY�t� Control#' r County Parcel No. v" b2AQ) SubDiv: 81 l Address/Location u24 rn Classfflcationrrype of Usp C� TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: , Exempt ❑Yes ❑ No How Determined I Impact Fee Amount Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7 ` (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt a Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total e Zone TOTAL AMOUNT $ ' Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total i Facility.Account Facility Credit Facility Total I� Exempt ❑ Yes [] No How Determined Total Amount I RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND- RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY !I Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment tot same. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes-35941 saddle palm way 3,239 sq ft Column ts ,y SQ. FEET PRICE MAIN OR LIVING: 3,239 $ 112.65 • OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - I VALUATION $ 364,873.35 i- FEE SHEET $ 1,865.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,977.30 ELECTRICAL: $ 419.63 PLUMBING: $ 279.75 MECHANICAL: $ 195.83 SUB-TOTAL $ 2,872.50 TOTAL $ 2,872.50 SEWER: WATER: IRRIGATION: $ TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 j FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,425.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,632.69 • Lennar Homes 35941 Saddle Palm Way 3,239 Sqft Column SQ. FEET PRICE MAIN OR LIVING: 3,239 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - I VALUATION $ 364,873.35 FEE SHEET $ 1,865.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,982.30 ELECTRICAL: $ 419.63 PLUMBING: $ 279.75 MECHANICAL: $ 195.83 SUB-TOTAL $ 2,877.50 Public Fee 1% TOTAL $ 2,877.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,430.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,628.00 100.0% $ 7,628.00 1.0% $ 76.28 TOTAL: $ 7,704.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 i ra TOTAL: $ 159536.69 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8 above the road elevation and an engineered site plan. fl 2. Lots shall be.graded to comply with R401.3 of the F.B.C. 3. Compaction test required:if 24"'or more of fill dirt.is brought in at any one place. 4-. Tie in survey required before pouring,concrete. 5. Driveways require a R.O.W. use permit. All 4:sides of driveway thru the sidewalk shall have expansion material: 6. All.setbacks shall be met.. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9.. No:electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first.. 10. All Garages shall comply with section R302.6 of the F.B.C.. (Fire Separation). II. Appliances shall not be installed in a location where subject to mechanical_damage unless protected by approved barriers. M303.4:of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units-shall be raised at least 3" above finished grade. M13.08.1: 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the.F.B.C. 16. All glazing requirements are to be in accordance with R308.4.of the F.B.C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board shall not be used as a backer in showers or tubs. R702.4:2 F.B.G. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker: . 20. Carbon:monoxide.alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage: They shall be installed in accordance with the F.B:C: 21. All plumbing,mechanical, and electrical shall be separate from unit to.unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C: Codes will be enforced. 23. Tamper=Resistant Receptacles in accordance with 406:11 of the 201-6 N:E:C 24. In accordance with the Land Development Code, lots shall be sodded before final:at least 10 feet around the structure. 25. Blower door test shall be provided before C.O. 26 A copy of the enerffy eacls shall be with permitt at dll times 27.. Copy of final insulation report shall be..provided with.permit before:fnaL 28: No Miice;:pool or screen enclosure is:issued with this permit F.F.E.-Finished Floor Elevation F.B.C­Florida Building Code 6a'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)