Loading...
HomeMy WebLinkAbout19-20745 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20745 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL -.PERMIT INFORMATION LOCATION INFORMATION , Permit#:20745 Issued: 1/30/2019 Address: 35957 SADDLE PALM WAY Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est.Value: Book: Page: Cost: 453,979.50 Total Fees: 16,300.19 Subdivision: SILVERADO Amount Paid: 16,300.19 Date Paid: 1/30/2019 Parcel Number: 05-26-21-0080-00500-0180 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 4,030 SQ FT APPLICATION_ FEES BUILDING FEE 2,431.20 ELECTRICAL FEE 519.75 PLUMBING FEE 346.50 MECHANICAL FEE 242.55 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections Required F OTER 2ND RO PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental, entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance' with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. �b(dNtRAifToF5,s-s-k5RATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ' ! ` Fox-83-780-002 Building Department Date Re&e'ived Phone Contact for Permitting 813 363 289-1 17771 Owner's Name Lennar Homes,LLC owner Phdne Number 813.574.5700 Ownees Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee_Simple Titleholder Na E_�_�� �� � Fee Simple Titleholder Address 35957 / JOB ADDRESS LOT# guBoK/ISKOm Silverado Ranch Subdivision Ph 6,8,9APARCELUl# 05-26-21-0080-00500-0180(OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED mawoomITn ADD0A�' �---1 G|8N �--1 F--1 DEMOLISHP[--~ INSTALL R REPAIR PROPOSED USE GFR �—1 COMM F---� OTHER ' TYPE OFCONSTRUCTION BLOCK [—1 FRAME �---1 STEEL � DESCRIPTION OF WORK [�in�Ie Family Residence Pool/Screen Enclosure Fence RSF � _=_ 1*0 BUILDING SIZE eoFPOTAGEE�E_] HEIGHT 0 BUILDING 1$ VALUATION",TOTAL CONSTRUCTION � �s�nK�L FX� PRO�REa sNsR�Y �—| \��E�y PROGRESS ENERGY�--^ AMP SERVICE �wy UPLUMBING MECHANICAL VALUATION OF MECHANICAL INSTALLATION [--] V\G88 �� U R�OP\�� [-� SPECIALTY OTHER OTHER ��` �--� [--�. FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA U UYE8 | pO � �� �� BUILDER SIGNATURE REGISTERED Y/_N_ rss»unma Address 4600 ress FL 33607 License# ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED _Y/ N_J pssuuxnsx Address Um,non# PLUMBER COMPANY 113ayonet PIUMbing, Heating &AC, Inc SIGNATURE REGISTERED Y7_N_J psEuunnsN xdd,oeo Lioonoo# MsCVAN|CAL —COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N rcsconwsx Address Licenoo# OTHER All COMPANY Lter�rin:g Quality Roofing, Inc SIGNATURE REGISTERED Y!N psscoRREN L_ILN_j 4ddmmo License# ICCC057991 . munuxmnnxxUxonnxnmKnuomxmxxmxxoxnnuonxo8xUxuKo8xwnx0xxuxuxmu * xnmxmn RESIDENTIAL Attach(2)Plot Plans;pg sets of Building Plans;(1)set x[Energy Forms; R-}4m Permit for new construction, Minimum ten(1V)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities&1 clumpotec Site Work Permit for subdivisions/large projects COMMERCIAL Attach;Z>complete sets nf Building Plans plus aLife Safety Page;(1)set uf Energy Fnnno.�-O4mPermit for new construction. Minimum ten(1D)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I clumpster,Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. . -PROPERTY SURVEY required for all NEW construction. \ u/mct/vno: . Fill out application completely. | Owner&Contractor sign back of application,notarized If over$oaOo`a Notice nf Commencement isrequired. (VC upgrades over$T6Dn) ' � Agent(for the contractor)or Power of Attorney(for the owner)would bo someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy s[contract required) Rommfs if shingles Sewers Service Upgrades A/C Fenuom(P|oVGumey/Footage) | | Driveways-Not over Counter Ifon public mudvnaya'neodoROW , NOTICE OF DEED RESTRICTIONS: The undersigned ondanabandnthatUlhypennitnleybeaubeottz ^deod^ naathctiona" which may be more restrictive than County regulations. The undersigned Goounleonsspomsibi|hvforoonlp|hanoevvithany applicable deed restrictions. " ` QNL ICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by /suw, both the owner and contractor may be cited for misdemeanor violation under state law. If the owner or intended contractor are uncertain as to vvho1 licensing naquimarnenha may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired m contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor B|noh" of this application for which they will be responsible.' If you, as the owner sign as the oontocbor, that may bean indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of Use in existing buUdinga, or expansion of existing bu||d|Mga, as specified in P000V County Ordinance nurnber8Q-D7 and SO-O7. eoamended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "oarUfiooha of occupancy" or final power na|maae. If the project does not involve a certificate of occupancy or final power na|aooa, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, asmmemded): |f valuation of work iG$2.5OO.00ormore, | certify that |, the app|io@nt, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared bv the Florida Department of Agriculture ond`��onnuma[Affairs. |f the uppUnentiosomeone �other than the"mwOe . ice�ifv that | have obtained a copy oY the above describaddocument and promise in good faith to deliver itho the"ownor" prior hocommencement. CONTRACTOKS/OMKyNEWS AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |avvg regulating conot[Vction, zoning and land development. Application in hereby mode to obtain e permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating conctruotion. County and City codes, zoning regulations, and land development regulations |n the jurisdiction. | also certify that I understand that the regulations of other government agencies may apply to the intended-work, and that it is nny responsibility to identify what actions | must take tobeincompliance. Such agencies include but are not limited to: ' Department ofEnvironmental Protection-Cypress Bayheodo. Wetland Areas and Environmentally Sensitive Lando. VVotec88haotewatarTneatnnant. - Southwest Florida VVobsr Management D|nthot-WeUs, Cypress Boyheadn. Wetland Anaao. Altering \8atarnnureeo. - Army Corps ofEnginears-SaoxvaUe. Docks, Navigable Waterways. - Department of Health & Rehabilitative 8an/iuem/Env|nnnrnanta| Health Unh'VVaUm, VVeetevvedar Treatment, Septic Tanks. - USEnvironmerita| Protection Agency-Asbestos abatement. - Federal Aviation Authohty-Runvva . | understand that the following restrictions apply bz the use nf-OU: - Use of fill |o not allowed in Flood Zone"\y' unless expressly permitted. '- If the fill material is to be used in Flood Zone 'YY', it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using mtarn vvaU construction, | certify that fill will.be used only tO fill the area within the stem wall. - If fill rnederio| is to be used in any area, | oorbfx that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent proparbee, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for |Ctn |eSg than one (1) acre which are elevated bv fill, an engineered drainage plan |nrequired. If am the AGENT FOR THE OWNER, | promise in good faith to inform the owner ofthe permitting conditions set forth in this affidavit prior to commencing construction. | understand that separate permit may be required for electrical vvork, p|unnbing, signs, vveUa, poo|a, air conditioning, gas, or other installations not specifically included in the application. 8 permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, after, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permitissued shall become invalid unless the vvod« authorized by such permit is commenced within six months of permit ismuonoe, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced, An extension may be requentmd, in writing, from the Building (]Oiuio| fora period not to exceed n|nab/ /90\ days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT yYWYOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO TAIN FINANCING, LT WITH YOUR LENDER OR AN ATTOR.NEY BEFORE RECORDING YOUR NOTI F COMMENCEMENT. OWNER OR AGENT /Z. CONTRACTOR Subscribed and sworn Subscribed°''"=,Who is/are pe;;nally known to me or hasihave pi;eduee4 Who is/are personally known to me or ham4ave pfedueeel identification. as identification. Notary Public Notary Public Commission No. BB98537 Commission No. Ff98557 IDi muM.lIoDozao ElimaM.Holleran PASCO COUNTY, FLORIDA Permit No. ZD 17 Date Permitted k--,96—t Builder Name/Owner Name /jevlil,A),2 a L&P control* ' County Par..cel No. Address/Location —1J q5 add A" Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes [] No How Determined Impact Fee Amount $. 31 b 3 Zone No. TAZ: SCHOOL IMPACT FEE p� Account (056) Single-Family Detached House Amount $ 7A0Jam• 28 (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt dyes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ 76 7. SL Exempt ❑Yes ❑ No How Determined LIBRARY FEE i Land Account Land Credit Land Total i Facility.Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amounk:; � RESOURCE FEE , ERU TOTAL AMOUNT Prepared By � Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY i Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes-35957 saddle palm way 4030 sq ft o umn ts • SQ. FEET PRICE MAIN OR LIVING: 4,030 $ 112.65 i OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 453,979.50 FEE SHEET $ 2,310.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 2,431.20 ELECTRICAL: $ 519.75 PLUMBING: $ 346.50 MECHANICAL: $ 242.55 SUB-TOTAL $ 3,540.00 TOTAL $ 3,540.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,093.35 PARK IMPACT FEES $ 769.56 i SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 16,300.19 Lennar Homes 35957 Saddle Palm Way 4,030 Sqft Column i SQ. FEET PRICE MAIN OR LIVING: 4,030 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 453,979.50 FEE SHEET $ 2,310.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 2,436.20 ELECTRICAL: $ 519.75 PLUMBING: $ 346.50 MECHANICAL: $ 242.55 SUB-TOTAL $ 3,545.00 Public Fee 1% TOTAL $ 3,545.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,098.35 PARK IMPACT FEES $ 769.56 SIF'S: $ - 7,628.00 100.0% $ 7,628.00 1.0% $ 76.28 TOTAL: $ 7,704.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 16,204.19 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of8 above the road,elevation and an engineered site plan. 2'. Lots shall be.graded to comply with R401.3 of the RB.C. 3. Compaction test required:if 24" or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring.concrete. 5. Driveways require a R.O.M. use permit. All 4 sides of driveway thiu the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All.property.markers shall be uncovered and marked at time of first inspection. 8. .All A.D.A. requirements shall be met. 9. No electric,plumbing,mechanical, or framing shall be covered without an:inspection and approval first.. 10. All Garages:shall comply with section R302.6 of the F.B.C. (Fire separation). I L.Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water;heaters shall comply.with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4.of the F.B.C-. 17. All means of egress are to be in accordance with R311 of the F.A.C. 18. "Green gypsum board shall not be 'used as a backer in.'show' or tubs. R702.4:2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil.-burning heating- or appliances or an attached garage.' They shall be installed in accordance with the F.B:C: 21. All plumbing,mechanical,.and electrical shall be separate from-unit to.unit. This includes all underground plumbing and electric. 22. All. 2016 N.-E.C. Codes will-be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C 24. In accordance with the Land Development Code, lots shall be,sodded before final:at least 10 feet around the structure, 25.BloWer door test shall be provided before.:C:O. 26.. A copy of the enemy cdcls shall be with permit at dll times 27.' Copy of final insulation report shall be..provided with:permit before:Ling 28:No fence:,pool or screen enclosure is:issued with this permit.- F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6"'Edition R.O.W.-Right of-Way- A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) - ----------- - N -103 LOT FAD W4---------- - 011 ..- -I I : 20 0 CD PA J.5 C31) TYPr a 0�7 n fftf W.J.au 44 PADz:l ro 00.'6 LUT 26 I TPjE i U4 8 I rp 1 0 1 �10 0 4 -00 41 6e I 42 PAD=' 2 60 7 Q,3 a1, I.Vi 27 -6 "1- PAD:�,106.� TyPt U. 4 9 ----------- VM:101 0 0 .90 LOT 26 X46 AUz1oo I/ �, -4 W'N 'fo 4o' \%'110 11%,, (U. Acl FF, ou LVI 19 FFz104-9D -Au�=Joo - 2 6 bc IrPE �Ap A It 4 y, FF=107. LOT I J rAU—106.3 FF -.ou 3 YAu— rAUzIol I 'a FAN A .71 —101.7o' A g Y- LOT 17 IV �cu r 4 IV � IV. 11AUZ:101 I -PY I V I IV 60 V "It PAD�--100:9 V,ml\ T ypu� I SKETCH ONLY SEC. 04,05 , TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS; LOT 18, BLOCK 5 SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT N MAY BE DISCLOSED BY A FULL AND ACCURATE TIR i E SEARCH ALSO SUBJECT TO SETBACKS, ON LOT AREA CALCULATIONS EASEMENTS AND RESTRICTIONS OF RECORD. LOT = 7556.25SO. FT_ LIVING AREA = 1358 SO. FT_ M UNDERGROUND FOOTER, STEM WALL, AND ENTRY =_1Z___SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED PR GARAGE = 644 —SQ. FT. SHOWN. COVERED LANAI =—N/A SO. FT. PATIO _ !2_/A_SQ. FT_ w DO NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE =—A44—SQ. FT. Ja NOTES TAKE PREFERENCE. A/C & CONC PAD = 25 --SO, FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND PRIVATE SIDEWALK = 28 --SQ. FT. IMPERVIOUS = 37 PAGE INDICATES THAT PLAT IS IN =— 2771 —SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO SOD = A7_fL5_SQ. FT. CHANGE AND/OR REVISION. CERTAIN DATA SHOWN HEREON BASED ON OFF LOT AREA CALCULATIONS ENGINEERING PLANS PROVIDED BY CLIENT. RIGHT OF WAY = U_70-D9_SQ. FT. DRIVE APRON =__1!i0__SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK =--12-5SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD = !LQ_5__SQ. FT. TO PROPERTY LINE. TOTALS 10' UTILITY EASEMENT AREA =_!Z2-6-25—SQ. FT. DRIVEWAY (L 34 --SO. FT. SIDEWALK =__.10_SQ. FT. SOD =_AZ4DSQ. FT. PRELIMINARY DRAWING: TRACT E DRAINAGE AREA THIS PLAN IS FOR PERMITTING PURPOSES ONLY, NOT FOR CONSTRUCTION. VERIFY . LOT 19 BLOCK 5 ALL DIMENSIONS BEFORE ANY CONSTRUCTION. -LEGEND: 05, -AA&--= PROPOSED DRAINAGE FLOW (00.00) = PROPOSED GRADE E-00.00 = EXISTING GRADE lb LIO U11 00 0 IGI �� \ Tk zo -000.50) 5r fro 7 BLWk b a o 1p 6i o C ZO .0 NOTES: LOT GRADING TYPE = B PROPOSED PAD ELEVATION = 100.8' FRONT SETBACK = 20' SIDE SETBACK = 75 PC(P) REAR SETBACK = 15' M PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 101.50' 9- X GARAGE AREA: DESCRIPTION: GARAGE REFERENCED TO LOT 18, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION NORTH AMERICAN VERTICAL 0PHASES 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 DATUM OF 1988. MEAN SEA lit THROUGH 080, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. Project LEGEND: APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 0913011992 Project Number: Square Fee 7556.25 LENNAR' HOMES (C)_ C C (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q-- CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= F/CEASEMENT, /C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED _9E PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT'CONTROL POINT, PRM= PERMANENT CL REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, WIF= WOOD FENCE z 9 JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SMS 0 SURVEYORS AND MAPPERS t 911 WEST ST. PETERSBURG DRIVE Checked By. ONE JRB OLDSMAR, FLORIDA 34677 >, WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' NOT VALID WITHOUT THE SIGNATURE AND JDate: PLOT PLAN 9/20/18 AGS 09 &D - 2 THE ORIGINAL RAISED SEAL OF A FLORIDA SI TURE DATE i f I LICENSED SURVEYOR AND MAPPER > HN R. EACH Revisions: FLORIDA R LAND SURVEYOR No. 2984 4493 JEFF M. HARTLEY L PRO AL SURVEYOR & MAPPER No.7123 i 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3341A sf ADS Carrier VW Builder Name: Lennar Homes 0518 Street: 35957 Saddle Palm Wa Permit office: y City o eph�hills City,State,Zip: ,FL, Permit Number: �. Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3074.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1493.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1141.10 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 439.83 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1996.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1996.00 ft2 6. Conditioned floor area above grade(ft2) 3354 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(302.8 sqft.) Description Area a.Sup:1st Floor,Ret:1st Floor,AH: 1st Floor 6 271.6 a. U-Factor: Dbl,U=0.33 142.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 399.2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 120.85 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 18.0 SEER:15.00 b.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.58 40.00 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.234 14.Hot water systems 8. Floor Types (2002.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1358.00 ft2 EF:0.950 b. Conservation features b.Floor over Garage R=11.0 644.00 ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 91.22 Glass/Floor Area: 0.090 PASS Total Baseline Loads: 96.43 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance aVe �G with the Florida Energy Code. D PREPARED BY: h Before construction is completed DATE: this building will be inspected for4 compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the j4handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. 1/15/2019 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 i 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3341A sf ADS Carrier VW Builder Name: Lennar Homes 0518 Street: 35957 Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3074.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1493.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1141.10 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 439.83 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1996.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1996.00 ft2 6. Conditioned floor area above grade(ft2) 3354 b.N/A R= -- ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(302.8 sqft.) Description Area a.Sup:1st Floor,Ret:1st Floor,AH:1st Floor 6 271.6 a. Q-Factor: Dbl,U=0.33 142.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 399.2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 120.85 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.58 40.00 ft2 b.Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.234 14.Hot water systems 8. Floor Types (2002.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1358.00 ft2 b. Conservation features EF:0.950 b.Floor over Garage R=11.0 644.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 91.22 PASS Total Baseline Loads: 96.43 i hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Q r`_ p Code. calculation indicates compliance + with the Florida Energy Code. PREPARED BY: Dave Aupch Before construction is completed DATE: this building will be inspected for , i compliance with Section 553.908 hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida-Energy Code. 'Op iNE` •. OWNER/AGENT: BUILDING OFFICIAL jA ff DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. 1/15/2019 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 f ' i FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3341A sf ADS Carrier VW Builder Name: Lennar Homes 0518' Street: 35957 Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) i 1. New construction or existing New(From Plans) 9. Wall Types(3074.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1493.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1141.10 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 439.83 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1996.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1996.00 ft2 6. Conditioned floor area above grade(ft2) 3354 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(302.8 sgft.) Description Area a.Sup: 1st Floor,Ret:1st Floor,AH:1st Floor 6 271.6 a. U-Factor: Dbl,U=0.33 142.00 ft2 b.Sup: Attic,Ref:2nd Floor,AH:2nd Floor 6 399.2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 120.85 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 18.0 SEER:15.00 b.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.58 40.00 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.234 14.Hot water systems 8. Floor Types (2002.0 sg a.Electric Cap:40 gallonsft.) Insulation Area EF:0.950 j a.Slab-On-Grade Edge Insulation R=0.0 1358.00 ft2 b. Conservation features b.Floor over Garage R=11.0 644.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 91.22 PASS Total Baseline Loads: 96.43 I I hereby certify that the plans and specifications covered by Review of the plans and Tk `ST.g; this calculation are in compliance with the Florida Energy s ecifications covered b thls Off` P 9Y P Y t Code. calculation indicates compliance with the Florida Energy Code. ' PREPARED BY: Dave Aupich Before construction is completed DATE: this building will be inspected for _C7 compliance with Section 553.908 hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIN DATE: DATE: i - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as j certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. 1/15/2019 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-7017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 3341A sf ADS Carrier VW Bedrooms: 5 Address Type: Street Address . Building Type: User Conditioned Area: 3354 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Vinyl windows CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1358 11678.8 2 Block2 1996 15968 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1358 11678.8 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1996 15968 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 97 ft 0 1358 ft2 0.3 0 0.7 2 Floor over Garage 2nd Floor ---- 644 ft2 11 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2162 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC i 1 Full attic Vented 300 1996 ft2 N N 1/15/2019 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1996 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w # Ornt Tn MIA Type RA/Alle Ft In Et In Area R-\Iqllfp Fraction Ahqnr Ccarfp% 1 N=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 20 8 8 8 179.1 ft2 0 0.600000 0 2 E=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 41 4 8 8 358.2 ft2 0 0.600000 0 3 S=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 7 4 8 8 63.6 ft2 0 0.600000 0 4 S=>E Exterior Concrete Block-Int Insul 1 st Floor 4.0999 43 4 8 8 375.6 ft2 0 0.600000 0 5 W=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 6 N=>W Garage Frame-Wood 1 st Floor 11 29 3 8 8 253.5 ft2 0.23 0.01 0 7 S=>E Garage Frame-Wood 1 st Floor 11 21 6 8 8 186.3 ft2 0.23 0.01 0 8 N=>W Exterior Frame-Wood 2nd Floor 11 50 8 0 400.0 ft2 0.23 0.06 0 9 S=>E Exterior Frame-Wood 2nd Floor 11 50 8 0 400.0 ft2 0.23 0.06 0 10 E=>N Exterior Frame-Wood 2nd Floor 11 43 4 8 0 346.7 ft2 0.23 0.06 0 11 W=>S Exterior Frame-Wood 2nd Floor 11 43 4 8 0 346.7 ft2 0.23 0.06 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1 st Floor None .2 3 6 8 20 ft2 2 N=>W Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.33 0.21 N 32.0 ft2 1 ft 0 in 10 ft 5 in Drapes/blinds None 2 S=>E 3 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 1 ft 0 in 11 ft 0 in Drapes/blinds None 3 S=>E 4 Vinyl Low-E Double Yes 0.33 0.23 N 69.0 ft2 1 ft 0 in 10 ft 5 in Drapes/blinds None 4 N=>W 8 Vinyl Low-E Double Yes 0.33 0.21 N 80.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N=>W 8 Vinyl Low-E Double Yes 0.33 0.21 N 8.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 S=>E 9 Vinyl Low-E Double Yes 0.33 0.23 N 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 S=>E 9 Vinyl Low-E Double Yes 0.33 0.23 N 9.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 W=>S 11 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 644 ft2 644 ft2 64 ft 8.6 ft 1 I 1/15/2019 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000367 3225.5 177.07 333.01 .339 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 17.7 kBtu/hr 1 sys#1 2 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 15 28.4 kBtu/hr 852 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1 st Floor 6 271.6 ft 1st Floor 67.9 ft2 Proposed Qn 1st Floor —cfm 81.5 cfm 0.06 0.50 1 1 2 Attic 6 399.2 ft 2nd Floor 99.8 ft2 Proposed Qn 2nd Floor —cfm 119.8 cfm 0.06 0.50 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb [ Mar A r [ j Ma rl Jun rl Jul X Au ri Se Oct Nov Dec Heating Jan Feb [ ]Mar f APr [ May Jun Jul AuSep Oct XNov X Dec Ventin Jan Feb X Mar [X A r [ May Jun Jul [ Aug Se [X Oct X Nov [ Dec I I 1/1 5/201 9 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 1 st Floor Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 2nd Floor Name: Signature: Rating Compant: Date: i i 1/15/2019 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 5 2'017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location varies 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 5 13. Cooling system: Capacity 46.4 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 3354 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.363 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.234 14. Heating system: Capacity 45.9 c)Area 7c. 302.8 a)Split system heat pump HSPF b)Single package heat pump HSPF 8. Skylights c)Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type,insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 11.0 15.Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10B1. 11.0 2.Masonry(Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11.Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded)in this home before final inspection. Otherwise,a new EPL display card will be completed based on i alled code compliant features. I Builder Signature: Date: 01/15/19 Address of New Home: 35957 Saddle Palm Way City/FL Zip: FL Zephyrhills,FL 33541 1/15/2019 12:37:07 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Analysis Job: 3341Asf ADS Carrier VW g Y Date: 111512019 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling i 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (OF) 38 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 Dry bulb(OF) 32 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 4.6 8477 42.4 Ducts Glazing 19.0 2655 13.3 nfiltration Doors 19.1 702 3.5 Ceilings 1.9 113 0.6 Wall Floors 3.6 4925 24.7 Infiltration 1.4 1591 8.0 Floors Ducts 1515 7.6 Piping 0 0 Humidification 0 0 Omer Ventilation 0 0 Glazing Doors Adjustments 0 Total 19979 100.0 i Component Btuh/ft2 Btuh % of load Walls 2.3 4281 29.3 Internal Gains Glazing 44.3 6193 42.4 Doors 15.6 573 3.9 Walls Ducts Ceilings 2.7 162 1.1 Floors 0.0 7 0.0 Infiltration Infiltration 0.3 362 2.5 other Ducts 1581 10.8 Daors Ventilation 0 0 Internal gains 1430 9.8 Blower 0 0 Adjustments 0 Total 14590 100.0 Glazing Latent Cooling Load= 1260 Btuh Overall U-value= 0.129 Btuh/ft2-°F Data entries checked. wrightsoft® 2019-Jan-15 12:39:14 ^�^• pew^•P� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..3341 sf ADS vW template 1.5-2.5tons Canierrup Calc=MJ8 Front Door faces:SW BuildingAnalysis Job: 3341Asf ADS CarrierVW Y Date: 111512019 upper floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa Intl AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 38 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 Dry bulb(OF) 32 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 o • Component Btuh/ftz Btuh /° of load Walls 3.7 4909 31.3 Ducts Glazing 17.8 2864 18.3 Wall Doors 0 0 0 Ceilings 1.2 2420 15.4 Floors 1.0 689 4.4 nfiltration Infiltration 1.4 2113 13.5 Ducts 2691 17.2 Piping 0 0 Floors Humidification 0 0 Glazing Ceilings Ventilation 0 0 Adjustments 0 Total 15686 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 3698 17.3 Glazing 45.2 7269 34.0 wall Internal Gains Doors 0 0 0 Ceilings 1.7 3477 16.2 Floors 0.4 273 1.3 j Ducts Infiltration 0.3 481 2.2 Ducts 2731 12.8 Ventilation 0 0 infiltration Internal gains 3470 16.2 they Blower 0 0 Glazing Adjustments 0 Ceilings Total 21399 100.0 i Latent Cooling Load= 3350 Btuh Overall U-value= 0.071 Btuh/ft2-°F Data entries checked. -Fp- =i-gh tsc t- 2019-Jan-15 12:39:14 •�° Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..3341 sf ADS VW template 1.5-2.5tons Carrier.rup Calc=MJ8 Front Door faces:SW Project Summary Job: 3341A sf ADS CarrierVW J ry Date: 1/1512019 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Notes: Vinyl windows Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 38 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18464 Btuh Structure 13009 Btuh Ducts 1515 Btuh Ducts 1581 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19979 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 14590 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 936 Btuh Ducts 324 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1358 1358 Equipment latent load 1260 Btuh Volume(ft') 12105 12105 Air changes/hour 0.19 0.10 Equipment Total Load (Sen+Lat) 15851 Btuh Equiv.AVF (cfm) 38 20 Req. total capacity at 0.85 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC518A00300 Cond 25HBC518A00300 AHRI ref 9154643 Coil FB4CNP025L AHRI ref 9154643 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 15300 Btuh Heating output 17700 Btuh @ 47'F Latent cooling 2700 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.030 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Capacity balance point= 36 OF Backup: Input= 5 kW, Output= 18553 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fp- wrightsoft- 2019-Jan-15 12:39:14 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 'CC` ...3341 sf ADS VW template 1.5-2.5tons Carrierrup Calc=MJ8 Front Door faces:SW Project Summary Job: 3341A sf ADS Carrier VW 1 •J Date: 1/15/2019 upperfloor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Notes: Vinyl windows Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 38 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12995 Btuh Structure 18668 Btuh Ducts 2691 Btuh Ducts . 2731 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15686 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21399 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2777 Btuh Ducts 573 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1996 1996 Equipment latent load 3350 Btuh Volume(ft3) 15966 15966 Air changes/hour 0.19 0.10 Equipment Total Load (Sen+Lat) 24750 Btuh Equiv.AVF(cfm) 51 27 Req. total capacity at 0.85 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC53OA00300 Cond 25HBC53OA00300 AHRI ref 9154945 Coil FX4DNF031L AHRI ref 9154945 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24140 Btuh Heating output 28200 Btuh @ 47°F Latent cooling 4260 Btuh Temperature rise 26 OF Total cooling 28400 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.064 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point= 18 OF Backup: Input= 5 kW, Output= 17428 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -117�&- wrightsoft- 2019-Jan-15 12:39:14 .�. '^ -• Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ACC` ...3341 sf ADS VW template 1.5-2.5tons Carrier.rup Calc=MJ8 Front Door faces:SW Manual S Compliance Report Job: 3341Asf ADS Carrier VW Date: 1/1 51201 9 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.4°F Sensible gain: 14590 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.2°F Latent gain: 1260 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 15851 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 105% of load Latent capacity: 2700 Btuh 214% of load Total capacity: 18000 Btuh 114% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 32.1 OF Heat loss: 19979 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Output capacity: 17700 Btuh 89% of load Capacity balance: 36 OF Supplemental heat required: 2279 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 5.4 kW 93% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. 1 Wrightsoft` 2019-Jan-1512:39:14 •r•�re- uowM ,�N, Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...3341 sf ADS VW template 1.5-2.5tons Carrier.rup Cale=MJ8 Front Door faces:SW Manual S Compliance Report Job: 3341A sf ADS CarrierVW Date: 1/15/2019 upperfloor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.4°F Sensible gain: 21399 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.2°F Latent gain: 3350 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 24750 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Sensible capacity: 24140 Btuh 113% of load Latent capacity: 4260 Btuh 127% of load Total capacity: 28400 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 32.1 OF Heat loss: 15686 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Output capacity: 28200 Btuh 180% of load Capacity balance: 18 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip i Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 5.1 kW 111% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. wrightsofta 2019•Jan-15 12:39:14 �, •d•H��.o Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 A'(:;k ...3341 sf ADS VW template 1.5.2.5tons Carrierrup Calc=MJ8 Front Door faces:SW /s2 VN0,5 /4 PASCO COUNTY PASCBUILDING CONSTRUCTION SERVICES a' 8731 Citizens Drive Date:4/30/2019 COUNTY FLORIDA Suite 230 Oriel SvAcr4,1"M14NT Plncrs. New Port Richey,FL 34654 NOT =847=8126 NOT A F"ERMIT Receipt#: 1852507 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1453454 $45.00 $45.00 1852507 4/30/19 Waste-Single Family TOTALS: $45.00 $45.00 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1852507 Check 01212947 MLARNOLD BCCCP59W 04/30/2019 $45.00 Total Payments: $45A0 Payor Address Phone L'ennar Homes, LLC Comments: '35957 Saddle Palm Way. While you Will be paying your bill with Pasco County Building Construction Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by Fltst Bllling payment services. i I i I I MyReports/reports//PASCOPROD/PASCO/ReceiptAA V7.rpt 4/30/2019 Page 1 of 1 Jet Stream° Ultra Slowing Wool Insuldtion Attic and Cavity Wall Card i dime h lave,evter�t Batts and Blankets Equipment Required When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum'YV internal corrugation,a minimum length recommendations,Knauf Insulation baits and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5-35lbs/minute.Recommended feed provide the full R-value. rate Is 15-25 Its/minute. R.value* _Minimum Thickness Thermal Performance(Sidewall and Attic Application) Installed The stated thermal resistance R value is provided b installing in accordance with the manufacturer's instructions.Failure to install the To obtain st insulation should ( ) y g Insulation resistance not be less than: required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label (R-Value)of: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. R49 13,75' Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. R-38HD 10.25" R-38 12.00' R-Value* Bags per 1000 SF Maximum Net Minimum R-30HD 8.25' To obtain an The number of bags Coverage per Bag Weight per SF Insulation per 1,000 square feet Contents of this The weight per square R-30 10.00, Cavity resistance of net area should not bag should not feet of installed insulation R-26 9.00, Framing Depth' of: Density be less than: cover more than: should not be less than: R-22 6.50" 2'x 4" 3.50" R-15 1.8 IbsJcu,ft. 16.4 bags 61.0 sq.ft. 0.525lbs. R-21 HD 5.50" 2"x 6" 5.50' R-23 1.8 lbsJcu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. R-19 6.25... R-15HD 3.50" 2"x 8" 7.25' R-31 1.8lbsJcu.ft 34.0 bags 29.4 sq.ft. 1,088 lbs. R-13 3.50" 2"x 10" 9.25' R49 1.8 lbs./cu,ft. 43A bags 23.1 sq.ft. 1.388 lbs. R-11 3,50' R means resistance to heat flow.The higher the R-ratue,0te greater the insulating power.-to get the marW R-value,d is essential that this insulation be installed properly. R-8 2,50" "R-18ina5.5'cavity.Conforms bASTM C665 and Federal Open Attic Application Bag Net Weight-Nominal 321bs.,Minimum 31 lbs. speaficatbn t��Hs21F. a.f: Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** To compensate for framing members.the number of bags per The number of weight/SF ba sl contents of this The wei Thickness 1,000 sq.ft.of area to be insulated should be as shown below, R-Value* D D contents of this 1,OD0 SF of net area bag should not of installed Installed insulation bag should Bags/MSF Bags/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more resistance(R-Value)of: than: more than: be less than than: than: Joist 16'Framing framing ming Fra O.C. ming O.C. R-Value Dimensions R-60 29.7 33.6 SF .9521bs. 19.750" 19.750' � fra 2x4 J 29.2 29.4 R-49 23.5 42.5 SF .753 tbs. 16.375" 16.375' R-60 2e6 11 28.9 29.1 R-44 20.9 47.8 SF .670 lbs. 14.875" 14.875' i 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 tbs. 13.000" 13.000' 2x= 23.0 23.2 R-30 13.6 73.3 SF .437lbs. 10.375' 10.375' R-49 ' 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 tbs. 9,125' 9A25' 2x8 2Z.4 22.7 R-22 9.8 102.2 SF .313 lbs. 7.750" 7.750" 2x4 20.4 20.6 R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 tbs. 6.750" 6.750" 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750" 2x4 17.3 17.4 R-11 4.7 210.8 SF .1521bs, 4.000" 4.000" R-38 2x6 17.0 17.2 6agMetwe9M nannet320s GTidnum310s 2x8 16.7 17.0 Coverage andinsfdiarpr dalayme demmiriedusing aVdMafie Ittla•.ing machine In nard gearNh 3 niemaCy-cormgefedhose. 20 13.2 13.3 lids pM&4 cantams to the pednrmance mquiremenb olASTM C 764,Type 1.and cancelled Federal Spedr vion HH•61e36a.Type 1,noes B.R-valuds are determined in ecsardanee wo c a87 and c sl6. -R'means resistance to heat lbw.The higher the R- Me,the greater the6lsulagng parser.To gel the marked R•value,it is essential OW ft imuldion be installed pro".it you do 4 yoursu.get hstn* R-30 2x6 12.9 13.1 done and t them x.In:tmvensdo not ones 041hfpaatagd., 'Based onWe Fair 2-yearsedni;A4.she predicted sebtd erdam a2aiaerpariod emuldbe f perzmtorlam This amount of WMVis tMmc!/imignificant Themlare,theistatied and set6ef 2x8 12.6 12.9 Mmeraeaametfectiverymdseme. 2x4 11.3 11.4 VdVA35ar41 is a registered bademak of unisut R-26 2x6 11.0 11.2 Builder's insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 2x6 9.1 9.3 Attic Area R- at Inches 2x8. 8.8 9.1 Sloped Ceilings R- at Inches 2x4 7.9 8.1 Malls R- at Inches R-19 2x6 7.7 7.9 2x8 7.4 7.7 Floors(over an unheated crawl space) R- at Inches 2x4 5.3 5.4 Crawl Space P ter R- at inches R-13 2x6 5.0 5.2 Date Installed �" #�o 2x8 4.8 5.0 Slowsu tion has been' in conformance with the above taco r �rovide an R-value of: 2x4 4.3 4.4 R_ ; using bag 2x8 s of this insulation to cover square feet of area LR-1 2x6 4,1 4.3 at a minimum thickness of inches. 3.8 4.i u6rnvtrwnment Insulation contractor(sicnatu ) GRI1110U fID Geld- x�atm"mmn5am"sr",urdd.nedae a company /c` urs>ri GRa:raGuaRo Gaao"a r, �e.,,� �g° ul En6"rm-m Udm.d.b.rem:eM-6yae 6. PmW-�GuaRD Home Builder(signature) Certfftudi- Fed hortru4Sad b Ul E.riro-i GRrst+ra ARDdQ dn,dst-It dwmiwl comparry Date Foon 4A.W-e6 dWV p od,.1...Ra r mere mramm ee,„m"t.c.m/Re. The coverage information on this Attic/Sidewall card applies to the entire United States(including Minnesota). ;.._...,.f,...,;_ - rlNwwsk auf= ..: k . Knauf Insulation Inc. 0 Shelbyville, - el � .4434 ext,8300 FAX:(317)398-3675 ,,., .....:•s...,...,-. •:���•r .nsu a:��:�'>�;�..,:,. -•.?��r,�:- .._,.......,._._...._..�..._ ..._ne Knauf Drive, ...,.....m_4 1......... TehJ(800)825 .._. ..-.,_--__.___..._.__ ...._...----M..•. :w= ,..z.»�•a.� :,�.-- _ m. s ,,,,,,;;�:��,,�..�>�:,.. e.Shelb Ile,IN 6 76 A 9t115 Knauf Insidatinn Inc bi.ldld '-­ an.0 ser"ices ;B", Ft.oizfl'�A Don-ny Test Report Foreyl Property Address-, Unit M 35q57 &-c1d[,e.?91M 2elp Ai(A Fl, 53 5,q Permit#: -4Vl�6 V Testing Company Name: S Test Date: 05 Tester Name: 'ic"I 01-f-", A Tester Cert M &WIAOI Contact Phone: qC4- 112-9- q000 Email: a+,_lops iltlp+e,r_ coov, 402.4.1.2 Testing. Building envelope air tightness shall be demonstrated by Section 402.4.1.2 The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). As required by the Building Official,testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test( including Agency Name)and provided to the Building Official prior to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled penetrations of the building thermal envelope. During testing:(check to verify condition met) dExterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended Bather-stripping or other d/Dampers including exhaust, intake,makeup air, backdraft and flue dampers shall be closed,but not sealed beyond tended infiltration Interior doors,if installed at the time of the test,shail be open dExterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed &eating and cooling systems,if installed at the time of the test,shall be turned off d5upply and return registers,if Installed at the time of the test,shall be fully open Vb Building volume(W) (A re Qso Airflow at 50 Pascal(CFM) 7_117— ACH5o Air changes per hour at 50 Pascal Q5o x 60—Vb = 14. 6cl ACH50 (3.OACHminimum) Pass 2f Fail F-1 ❑Outside Air mechanically introduced to space(less than 3.0 ACH) ;f t t e aboy velope leakage performance results demonstrate compliance I hereby cerntify w F E 5n with a Code e u' ments in accordance with Section R402.4.1.2. Signa,d, e of Tester Date