HomeMy WebLinkAbout19-20746 ' CITY OF ZEPHYRHILLS
5335-STH STREET
(813)780-0020 20746
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20746 Issued: 1/30/2019 Address: 3305 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 256,391.40 Total Fees: 18,396.47 Subdivision: HIDDEN RIVER
Amount Paid: 18,396.47 Date Paid: 1/30/2019 Parcel Number: 24-26-21-0100-00000-1300
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY HOME.2,276 SQ FT
APPLICATION FEES
BUILDING FEE 1,426.49 -ELECTRICAL FEE 298.13 PLUMBING FEE 198.75
MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEN- 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28
Inspection Inspectioni Required
F OTER 2ND ROUGH PLUMB Misc INSULATION CEILI G
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or!
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that,
may be found in the public records of this county, and there may be additional permits required from other governmental!
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
IfONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
PASCO COUNTY, FLORIDA
Permit No. .ZO IV/
// - Date Permitted (- —
Builder Name/Owner Na/mew C!��l �tDYvre Control#'
County Parcel No. �Y °��/ ��d yy�"��DO SubDiv: GTGfPfI�Cl f�Y'
Address/Location 330S � �-
Classification/Type of Use S1� L,, 2,L7�
TRANSPORTATION IMPACT FEE Rate: Sq-R Unit: 2-, z7�i
Exempt ❑ Yes ❑ No ! How Determined
Impact Fee Amount $. 3 32, Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
723) Collection Fee
Exempt [ Yes ❑No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 76 9- 56
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility.Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amou
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
U .
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placirig
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
PASCO COUNTY
pis C
Y` BUILDING CONSTRUCTION SERVICES f
8731_Citizens Drive Date:4/30/2019
COUNTY FLORIDA111110r- Suite 230
OPEN SPncrS.h'rnm-vT Pvccs. New Port.Richey,FL 34654
727-847-8126
T A PERMIT
Receipt#: 1852402
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE:# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 1.00 1453412 $45.00 $45.00 1852402 4/30/19
Waste Single Family
TOTALS: $45.00 $45.00
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1852402 Check 01212938 MLARNOLD BCCCP59W 04/30/2019 $45.00
Total Payments: $45.06
Payor Address Phone
Lennar Homes, LLC
Comments:.
3305 Kresterbrooke LN -7 4
While you will he paying your bill with Pasco County Building Construction services,the full amount of the credit card or a-check fees,NOT shown above,Is
collected by First Billing payment services.
MyReports/reports//PASCOPROD/PASCO/ReceiptAA_V7.rpt 4/30/2019 Page 1 of 1
i
Jacqueline Boges
From: Jordon Davis (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, February 6, 2019 2:48 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3305 krestrbrooke lane by#20746
##- Please type your reply above this line -##
Your request (#262075) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/262075
.......................................................................................................................................................................................................................................................................................................................................................................................
.0 1 Jordon Davis (City of Zephyrhills Support )
--� Feb 6, 1 2:48 PM MST
WO#765370 created to install new meter to the property
Best Regards,
Jordon I FATHOM Support
............................................... ......................................................................................................................................................................................... ..... ............................................................................ ...............................
Jordon Davis (City of Zephyrhills Support )
Feb 5, 4:47 PM MST
Account has been added and is being mapped. Account number is 0000889145-003124244
Best Regards,
Jordon I FATHOM Support
................................................................................................................................. ..................................................................................................................................................................................................................................
[ Jacqueline Boges
--- Feb 5, 3:10 PM MST
i
service 30 kresterbroo�e�lane fW4jP207-46-
This email is a service from City of Zephyrhills Support .
1
/
n`»''uv-U»zu City of Zephyrhills Permit Application Fox-813-780-0021
Building Department
J�" ' �, '
Owner'sDate Received Phone Contact for Permittin 1( 813 363 2891
r813— Name 5700
33607
Omme/sAddn*m, Owner Phone-Number
Fee Simple Titleholder Name I Owner Phone Number
Foe Simple Titleholder Address
JOB ADDRESS'
LOT#
SVBDNua|om Hidden River Phase OnepARCEL|D# 24-26-21-0100-00000-1300(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED mowcomsm ADD�J][ �---1 S|oN F--� [--1 DEMOLISH
INSTALL �_] REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION oFWORK mily Residence Pool/Screen Enclosure/FenceU/R IF
276
BUILDING SIZE SQ FOOTAGE i,'�. ] HEIGHT 1 Story
UV/ BUILDING $ 2,67b) VALUATION OF TOTAL CONSTRU'CTION
0 �kELECTRICAL V� ��| PROGRESS F—� \��EC p �� � �--� W.R.E.C.
�—� AMP SERVICE
U»r
����pLUMB|No �
YMECHANICAL VALUATION OF MECHANICAL INSTALLATION
=GAG ROOFING F—� SPECIALTY = OTHER
--- �--� �--1
FINISHED FLOOR ELEVADONS FLOOD ZONE AREA DYES ) NO
�� ��
BUILDER COMPANY
�ar LHomes,LLC
SIGNATURE �� �Fss Cunmsk�
Address' Liconuo# i CGC1518166 '
ELECTRICIAN COMPANY =Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/,IN pssnunnsx
.
Address 110,34 Skipper Road,Tampa6FL 33613 License#
PLUMBER [�� .
SIGNATURE REGISTERED _Y/_N_] FssooeRsx //lN_�
Address Lioonso#
MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc
SIGNATURE REGISTERED _Y/ N�l
Address License#
OTHER COMPANY C Sterling Quality Roofing, Inc .
SIGNATURE REGISTERED _y/ N ] pssnunnsx [�YlN�1 |
' Address 14211 Shoal Line Blvd, Spring Hrill, FL 346 License#
mxuuxmxunnuxmxnunmnmumxnuonnumomonxxmnoxxouxoxuxmnmxnxxmmxooxnmnxmo
RESIDENTIAL Attach(2)Plot Plans;(D sets of Building Plans; (1)set of Energy Forms;R,O4m Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,ConstructionPlans,Gtomnwaher Plans w/Silt Fence installed,
Sanitary Facilities-&11-dumpster;Site Work Permit for subdivislons/large-projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance '
/
SIGN PERMIT Attach Vq sets of Engineered Plans.
****PROPEFTY SURVEY required for all NEW construction. |
~^^~~~'~' '
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2600,a Notice of Commencement is required. (A/C upgrades over$7500)
� Agent(for the contractor)or Power uf Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy nf contract required)
Romofsifshingles Gowam Service Upgrades A/C Fenoen(P|nt/Sumey/Fontage)
|�
Driveways-Not over Counter ifon public muUwayu..needs ROW
NOTICE OF DEED understands that this permit may ba subject to^deedrestrictions"
which may be more restrictive than County regulations. The undersigned aseUrnesreoponsibUhxfOrconlD|iaDoevvithaOy �
applicable deed restrictions. ` ^
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not ||menomd as required by |suw, both the owner and contractor may be cited for o misdemeanor violation
under state |ovv. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contnaotoro, he in advised to have the contractor(s) sign
portions of the"contractor 8|ooh" of this application for which they will be responsible. If you, an the owner sign as the
contractor, that may bean indication that he is not properly licensed and in not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buUdingo, or expansion of existing bui|dinga, as specified in Pasco County Ordinance nurnber88-07 and
90-07. as o,nenUad. The undersigned also understonda, that such feeo, as may be dUe, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. |f the project doeono{ invo}veecerU5natmofocouponcyor
final power re|eaoe, the fees must be paid prior to permit issuance. Furthermore, if Pasco County VVobar/8evver Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, mmammemded): |f valuation of work is$2.5OO.00or more, |
certify that |, the app/icaDt, have been provided with G copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is eomnoVna
other than the"owOer"' | certify that I have obtained a copy of the above described document and promise in good faith to
deliver itto the"cwvne/' prior tncommencement.
CONTRACTOR'S/OWNER!S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable |emvs regulating conotrUotion, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. | oerbh/ that no work or installation has
onnlmenuod prior to issuance of permit and that all work will be performed to meet standards of all |avvn regulating
construction, County and City codes, zoning regulations, and land development regulations |n the jurisdiction. | also
certify that | understand that the regulations of other government agencies may apply to the intended vvork, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department ofEnvironmental Protection-Cypress Boyheoda, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management Diothot-WeUs, Cypress Bayheedo, Wetland Aneon, Altering
Watercourses.
' Army Corps ofEnginean*SeavveUs. Docks, Navigable Waterways.
- [Jepod0ant of Health & Rehabilitative Services/Environmental Health Unit-WeUa, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement,
- Federal Aviation Authority-Runways.
| understand that the following restrictions apply bo the use offill:
- Use nf fill io not allowed iO Flood Zone"\y' unless expressly permitted.
- If the fill rnotehal is to be used in Rood Zone "A", it is understood that drainage plan addressing a
''compensating volume" will be submitted at time of permitting which is prepared by m professional engineer
licensed by the State ofFlorida.
- If the fill rnoteho| is to be used in Flood Zone "N' in connection with a permitted building using stem vva|\
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill nlahyha| is to be used in any area, \ certify that use of such fi|| will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent propertieo, the owner may be cited for violating
the conditions of-the building permit issued under the attached permit application, for lots |ege than one (1)
acre which are elevated by fill, aD engineered drainage plan |orequired.
|f| ann the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. | understand that separate permit may be required for electrical xvOdk,
p/VmbiOg, signs, vVe||n, p#o|o, air coOditioniUg, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, o[ if work authorized by
the permit ia suspended or abandoned for m periodof six(8) months after the time the work |s commenced. An extension
may be naquemted, in vvhting, from the Building C)f5c|a| for period not to exceed ninety (QO) days and will demonstrate
justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR*FAILURE TO RECORD A NOTICE OF COMMENCEME MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OpT, IN �INANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OKCOMMENCEMENT
OWNER OR AGENT CONTRACTOR—
Subscribed and sworn to(or affirmed)beforyre this Subscribed and vtlWn to(or affirmed)before me this
' Who is/are personally known to me 0 is/areor
.FlAntofication. —as identification.
77;
Notary Public
Notary Public
Commission No. BF98537 Commission No. BF98537
ElissaM.Holleran ElissaM.Holleran
CX
TV bL
k t ►'
�►
env CD
' -%p. is a"' - a
�• � I :. �'-" 6�. �.�- .. . • I. . .�, • ... .,:_..is 1"'" �'; �.- � � .: �' ._:
,,, .• 1, B ;: 1 D ;> . may,
I. I
All
NAW
not
f � is t: � �; t � :. '�, i �; _� E � ,,� � .1 � � 1: ,I,-•,na r� �� � ,
�^T YfY•�I.t •IIYhY4e. 1/q� ..._ , -. �"..._._-.�h
I 1B r ' B II 1i i' t II
._rI•- .i+wI w,7�� •rr►�r.�..ad .aw.val�u� ... ._. .�...�� t �.r,.�.d pl �n-..tea.,re.res:�" .� �.
•---_ua_.r�, �d ut. ,� —w, i_� .R Y•..s 1—..M.+ .rR ar�., j .�.'��� ssY � � m ~'" _ �
4 Irma
to
. scar E f , B .t I
CI
'M-. - ts'�, .++t Ff•�MV�`+sR� - J�tn.s. -4i a.11 .Y� .•..����- s•er•sier��>r'.sF �. YYei fuu•`�+1 Via,. •1. ..-`-,L 9�
rm WON
- - .r
i
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of.8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Co* action test required if_24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R:O.W. use permit. All 4.sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric, plumbing, mechanical; or framing shall be covered without an:inspection and
approval first.
10. All Garages shall comply with section R302.,6 of the F.B.C. (Fire Separation).
I I, Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved_barriers. M303.4.of the F.B:C
12. Water heaters shall comply with section P607.3 of the F:B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms: F.B.C. M.1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.,
18. "Green gypsum board" shall not b' used ' a backer.in-showers or tubs. R702.4:2 F.B.C.
. . . .
19. Combindtion-type AFCI breakers are required at all locations requiring an AFCI:type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil=burning heating
or appliances or an attached pp garage: They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shall be separate from unit_to:unit. This includes all
underground_plumbing and electric.
22. All 2016 N.E.C; Codes will be enforced.
-23. Tamper- Resistant Rec septacle m accordance with 406.11 of the 2016 N.E.0
24. In accordance with the Land Development Code, lots shall_ be sodded before final-at.least 10
feet around the structure. f
25. Blower door test and blown in insulation card shall be provided before C.O.
26.. A copy of the energy cacls shall be with permit at.all times j
27.. Copy,of findl insulation report shall he.:proyided with:permit before:tinaL
28.No fence: pool-or screen_enelosure is issued with this oermirk.
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 60'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
r
Lennar Homes 3305 Kresterbrooke Ln.2,276 Sgft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 2,275 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,278.75
FEE SHEET $ 1,325.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,431.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,067.50
Public Fee 1%
TOTAL $ 2,067.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,194.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,628.00
100.0% $ 7,628.00
1.0% $ .76.28
TOTAL: $ 7,704.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,300.47
i
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION i
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0130i
Street: 3305 Kresterbrooke Lane Permit Office: City of 7�ephyrhills
City,State,Zip: ,FL, Permit Number:Z�
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ftZ
b.Frame-Wood,Adjacent R=11.0 331.33 ftZ
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1817.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ftZ
6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ftZ
Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ
11.Ducts R ftZ
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl, U=0.33 87.00 ftZ
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.58 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
I
c. U-Factor: Dbl, U=0.33 23.00 ftZ
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftZ a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.248 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features
b.N/A R= ftZ None
c.N/A R= ftZ 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS
Total Baseline Loads: 58.15
I hereby certify that the plans and specifications covered by Review of the plans and :Sx4
r � .,..
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
n with the Florida Energy Code. +
PREPARED BY: Before construction is completed r .
DATE: this building will be inspected for (�F 7--+
compliance with Section 553.908
I herebycertify that this building,as n is Florida Statutes.
fY g g d6i 2819mpliance
with the Florida Energy Code. alj'
OWNER/AGENT: JAN BUILDING OFFICIAL:
DATE: DATE:
i
- Compliance requires certification b e air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accords a with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.030 Gin for whole house.
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
r j I
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0130
Street: 3305 Kresterbrooke Lane Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
I
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 . 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl, U=0.33 87.00 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl, U=0.33 23.00 ft2
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.248 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS
Total Baseline Loads: 58.15
I hereby certify that the plans and specifications covered by Review of the plans and TiESx ;
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
"� //, with the Florida Energy Code.
PREPARED BY: Dave A>,Ul''ich Before construction is completed -,
DATE: this building will be inspected for _ d
compliance with Section 553.908
hereby certify that this building,as designed, is in compliance Florida Statutes. '
with the Florida Energy Code. 'd%�j'y :
OWNER/AGENT: BUILDING OFFICIAL: i
DATE: DATE.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.030 Qn for whole house.
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
t I
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0130
Street: 3305 Kresterbrooke Lane Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1817.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.33 87.00 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl, U=0.33 23.00 ft2
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.248 14.Hot water systems
8. Floor Types (1817.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
i
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS
Total Baseline Loads: 58.15
I hereby certify that the plans and specifications covered by Review of the plans and
0 .
this calculation are in compliance with the Florida Energy specifications covered by this ,
Code. calculation indicates compliance ,j�;''
with the Florida Energy Code. :
PREPARED BY: pave AUHM Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908 *<, =- :I•"I'
hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. oti'.y
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as j
certified factory�sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
1 �FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
I
Title: 1791A1 sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1817 Lot# i
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: 3540 vinyl windows
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1817 14536
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1968 ftZ 0 ft2 Medium 0.85 No 0.9 No 0 22.6 I'
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1817 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall Type
R-\/,ql,lp Ft In Et In Area R-Mahle Fraction Ahqnr rcafip%
1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0
2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0.23 0.01 0
3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0.23 0.01 0
4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0
5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0
6 W=>NW Exterior.- Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0
7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
2 E=>SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
3 S=>SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None
5 W=>NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 427 ft2 427 ft2 42 ft 8 ft 1
INFILTRATION
I
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 j
1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2649 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1
i
i
i
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name .System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area - Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar A r Ma X Jun X Jul X Aug �Xj Se Oct Nov Dec
Heatin Jan Feb Mar Apr May Jun Jul Au Sep Oct Nov Dec
Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/s .ft. 0 ft2 Oft 0.3 Main
Name: Signature:
Rating Compant: Date:
I'
I
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Attic/Main
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13. Cooling system: Capacity 28.4
a)Split system SEER 15.0
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned-floor area(sq.ft.) 6. 1817 d) Room unit/PTAC EER
e) Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.388
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.248 14. Heating system: Capacity 28.2
c)Area 7c. 143.3 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8.Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other 8.50
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised (R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g) Other
1.Wood frame(Insulation R-value) 10131. 11.0
2. Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: 01/15/19
Address of New Home: 3305 Kresterbrooke Lane City/FL Zip: . FL Zephyrhills,FL 33540
1/8/2019 6:53:36 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Buildin Anal $IS Job: 1791A1sf ADS Carrier VW
g y Date: 1/1 512 01 9
Entire House , By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 i
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb (°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
I.
Component Btuh/ftz Btuh % of load
Walls 5.0 9004 33.2 °°ts
Glazing 22.1 3488 12.9 nfiltratlon
Doors 19.7 726 2.7 wan
Ceilings 1.3 2271 8.4
Floors 3.4 6125 22.6
Infiltration 2.1 2882 10.6
Ducts 2616 9.6 Floors
Piping 0 0
Humidification 0 0 Glazing
Ventilation 0 0 Doors Ceilings
Adjustments 0
Total 27113 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.4 4378 19.6 Internal Gains
Glazing 43.1 6822 30.6 walls
Doors 15.4 569 2.6
Ceilings 1.7 3140 14.1
Floors 0 0 0 Ducts
Infiltration 0.5 645 2.9
Ducts 2982 13.4
Ventilation 0 0
Internal gains 3750 16.8 Infiltration
Blower 0 0 Glazing
Adjustments 0 Ceilings
Total 22286 100.0 Doors
I
Latent Cooling Load=2873 Btuh
Overall U-value= 0.098 Btuh/ftz-OF
Data entries checked.
=Ightsc ft- 201&Jan-1510:42:56
^�^•� w ^� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...ment\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: E
i
Project Summary Job: 1791A1 sf ADS CarrierVW
1 Date: 1/15/2019
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project I • •
For: Lennar Homes
Notes: vinyl windows
Design In • •
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24497 Btuh Structure 19304 Btuh
Ducts 2616 Btuh Ducts 2982 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 27113 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 22286 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2339 Btuh
Ducts 534 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ft2) 1817 1817 Equipment latent load 2873 Btuh
Volume(ft') 15431 15431
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 25159 Btuh
Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC53OA00300 Cond 25HBC53OA00300
AHRI ref 9154945 Coil FX4DNF031L
AHRI ref 9154945
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 24140 Btuh
Heating output 28200 Btuh @ 47'F Latent cooling 4260 Btuh
Temperature rise 26 OF Total cooling 28400 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point= 31 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrigt�tsof[® 2019-Jan-1510:42:56
.-� •-^� ^��-wm Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
�� ...ment\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: E
Manual S Compliance Report Job: 1791A1sf ADS Carrier=
Date: 1/15/2019
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 22286 Btuh Entering coil DB: 75.7°F
Outdoor design WB: 77.3°F Latent gain: 2873 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 25159 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Sensible capacity: 24140 Btuh 108% of load
Latent capacity: 4260 Btuh 148% of load
Total capacity: 28400 Btuh 113% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 27113 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Output capacity: 22528 Btuh 83% of load Capacity balance: 31 °F
Supplemental heat required: 4585 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1000 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
wrightsoft® 2019-Jan-1510:42:56
�. •w.Nf��ow�.o�-m Right-Suite®Universal 2018 18.0.16 RSU05714
Page 1
ACCK ...ment\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: E