Loading...
HomeMy WebLinkAbout19-20746 ' CITY OF ZEPHYRHILLS 5335-STH STREET (813)780-0020 20746 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20746 Issued: 1/30/2019 Address: 3305 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 18,396.47 Subdivision: HIDDEN RIVER Amount Paid: 18,396.47 Date Paid: 1/30/2019 Parcel Number: 24-26-21-0100-00000-1300 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY HOME.2,276 SQ FT APPLICATION FEES BUILDING FEE 1,426.49 -ELECTRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEN- 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28 Inspection Inspectioni Required F OTER 2ND ROUGH PLUMB Misc INSULATION CEILI G FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or! first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that, may be found in the public records of this county, and there may be additional permits required from other governmental! entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. IfONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. .ZO IV/ // - Date Permitted (- — Builder Name/Owner Na/mew C!��l �tDYvre Control#' County Parcel No. �Y °��/ ��d yy�"��DO SubDiv: GTGfPfI�Cl f�Y' Address/Location 330S � �- Classification/Type of Use S1� L,, 2,L7� TRANSPORTATION IMPACT FEE Rate: Sq-R Unit: 2-, z7�i Exempt ❑ Yes ❑ No ! How Determined Impact Fee Amount $. 3 32, Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 723) Collection Fee Exempt [ Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 76 9- 56 Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amou RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By U . NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placirig the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY PASCO COUNTY pis C Y` BUILDING CONSTRUCTION SERVICES f 8731_Citizens Drive Date:4/30/2019 COUNTY FLORIDA111110r- Suite 230 OPEN SPncrS.h'rnm-vT Pvccs. New Port.Richey,FL 34654 727-847-8126 T A PERMIT Receipt#: 1852402 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE:# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1453412 $45.00 $45.00 1852402 4/30/19 Waste Single Family TOTALS: $45.00 $45.00 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1852402 Check 01212938 MLARNOLD BCCCP59W 04/30/2019 $45.00 Total Payments: $45.06 Payor Address Phone Lennar Homes, LLC Comments:. 3305 Kresterbrooke LN -7 4 While you will he paying your bill with Pasco County Building Construction services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptAA_V7.rpt 4/30/2019 Page 1 of 1 i Jacqueline Boges From: Jordon Davis (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com> Sent: Wednesday, February 6, 2019 2:48 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3305 krestrbrooke lane by#20746 ##- Please type your reply above this line -## Your request (#262075) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/262075 ....................................................................................................................................................................................................................................................................................................................................................................................... .0 1 Jordon Davis (City of Zephyrhills Support ) --� Feb 6, 1 2:48 PM MST WO#765370 created to install new meter to the property Best Regards, Jordon I FATHOM Support ............................................... ......................................................................................................................................................................................... ..... ............................................................................ ............................... Jordon Davis (City of Zephyrhills Support ) Feb 5, 4:47 PM MST Account has been added and is being mapped. Account number is 0000889145-003124244 Best Regards, Jordon I FATHOM Support ................................................................................................................................. .................................................................................................................................................................................................................................. [ Jacqueline Boges --- Feb 5, 3:10 PM MST i service 30 kresterbroo�e�lane fW4jP207-46- This email is a service from City of Zephyrhills Support . 1 / n`»''uv-U»zu City of Zephyrhills Permit Application Fox-813-780-0021 Building Department J�" ' �, ' Owner'sDate Received Phone Contact for Permittin 1( 813 363 2891 r813— Name 5700 33607 Omme/sAddn*m, Owner Phone-Number Fee Simple Titleholder Name I Owner Phone Number Foe Simple Titleholder Address JOB ADDRESS' LOT# SVBDNua|om Hidden River Phase OnepARCEL|D# 24-26-21-0100-00000-1300(OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED mowcomsm ADD�J][ �---1 S|oN F--� [--1 DEMOLISH INSTALL �_] REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION oFWORK mily Residence Pool/Screen Enclosure/FenceU/R IF 276 BUILDING SIZE SQ FOOTAGE i,'�. ] HEIGHT 1 Story UV/ BUILDING $ 2,67b) VALUATION OF TOTAL CONSTRU'CTION 0 �kELECTRICAL V� ��| PROGRESS F—� \��EC p �� � �--� W.R.E.C. �—� AMP SERVICE U»r ����pLUMB|No � YMECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAG ROOFING F—� SPECIALTY = OTHER --- �--� �--1 FINISHED FLOOR ELEVADONS FLOOD ZONE AREA DYES ) NO �� �� BUILDER COMPANY �ar LHomes,LLC SIGNATURE �� �Fss Cunmsk� Address' Liconuo# i CGC1518166 ' ELECTRICIAN COMPANY =Edmonson Electric, Inc. SIGNATURE REGISTERED Y/,IN pssnunnsx . Address 110,34 Skipper Road,Tampa6FL 33613 License# PLUMBER [�� . SIGNATURE REGISTERED _Y/_N_] FssooeRsx //lN_� Address Lioonso# MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED _Y/ N�l Address License# OTHER COMPANY C Sterling Quality Roofing, Inc . SIGNATURE REGISTERED _y/ N ] pssnunnsx [�YlN�1 | ' Address 14211 Shoal Line Blvd, Spring Hrill, FL 346 License# mxuuxmxunnuxmxnunmnmumxnuonnumomonxxmnoxxouxoxuxmnmxnxxmmxooxnmnxmo RESIDENTIAL Attach(2)Plot Plans;(D sets of Building Plans; (1)set of Energy Forms;R,O4m Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,ConstructionPlans,Gtomnwaher Plans w/Silt Fence installed, Sanitary Facilities-&11-dumpster;Site Work Permit for subdivislons/large-projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance ' / SIGN PERMIT Attach Vq sets of Engineered Plans. ****PROPEFTY SURVEY required for all NEW construction. | ~^^~~~'~' ' Fill out application completely. Owner&Contractor sign back of application,notarized If over$2600,a Notice of Commencement is required. (A/C upgrades over$7500) � Agent(for the contractor)or Power uf Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy nf contract required) Romofsifshingles Gowam Service Upgrades A/C Fenoen(P|nt/Sumey/Fontage) |� Driveways-Not over Counter ifon public muUwayu..needs ROW NOTICE OF DEED understands that this permit may ba subject to^deedrestrictions" which may be more restrictive than County regulations. The undersigned aseUrnesreoponsibUhxfOrconlD|iaDoevvithaOy � applicable deed restrictions. ` ^ UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not ||menomd as required by |suw, both the owner and contractor may be cited for o misdemeanor violation under state |ovv. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contnaotoro, he in advised to have the contractor(s) sign portions of the"contractor 8|ooh" of this application for which they will be responsible. If you, an the owner sign as the contractor, that may bean indication that he is not properly licensed and in not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buUdingo, or expansion of existing bui|dinga, as specified in Pasco County Ordinance nurnber88-07 and 90-07. as o,nenUad. The undersigned also understonda, that such feeo, as may be dUe, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. |f the project doeono{ invo}veecerU5natmofocouponcyor final power re|eaoe, the fees must be paid prior to permit issuance. Furthermore, if Pasco County VVobar/8evver Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, mmammemded): |f valuation of work is$2.5OO.00or more, | certify that |, the app/icaDt, have been provided with G copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is eomnoVna other than the"owOer"' | certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the"cwvne/' prior tncommencement. CONTRACTOR'S/OWNER!S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |emvs regulating conotrUotion, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | oerbh/ that no work or installation has onnlmenuod prior to issuance of permit and that all work will be performed to meet standards of all |avvn regulating construction, County and City codes, zoning regulations, and land development regulations |n the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended vvork, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress Boyheoda, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management Diothot-WeUs, Cypress Bayheedo, Wetland Aneon, Altering Watercourses. ' Army Corps ofEnginean*SeavveUs. Docks, Navigable Waterways. - [Jepod0ant of Health & Rehabilitative Services/Environmental Health Unit-WeUa, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement, - Federal Aviation Authority-Runways. | understand that the following restrictions apply bo the use offill: - Use nf fill io not allowed iO Flood Zone"\y' unless expressly permitted. - If the fill rnotehal is to be used in Rood Zone "A", it is understood that drainage plan addressing a ''compensating volume" will be submitted at time of permitting which is prepared by m professional engineer licensed by the State ofFlorida. - If the fill rnoteho| is to be used in Flood Zone "N' in connection with a permitted building using stem vva|\ construction, I certify that fill will be used only to fill the area within the stem wall. - If fill nlahyha| is to be used in any area, \ certify that use of such fi|| will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent propertieo, the owner may be cited for violating the conditions of-the building permit issued under the attached permit application, for lots |ege than one (1) acre which are elevated by fill, aD engineered drainage plan |orequired. |f| ann the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that separate permit may be required for electrical xvOdk, p/VmbiOg, signs, vVe||n, p#o|o, air coOditioniUg, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, o[ if work authorized by the permit ia suspended or abandoned for m periodof six(8) months after the time the work |s commenced. An extension may be naquemted, in vvhting, from the Building C)f5c|a| for period not to exceed ninety (QO) days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR*FAILURE TO RECORD A NOTICE OF COMMENCEME MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OpT, IN �INANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OKCOMMENCEMENT OWNER OR AGENT CONTRACTOR— Subscribed and sworn to(or affirmed)beforyre this Subscribed and vtlWn to(or affirmed)before me this ' Who is/are personally known to me 0 is/areor .FlAntofication. —as identification. 77; Notary Public Notary Public Commission No. BF98537 Commission No. BF98537 ElissaM.Holleran ElissaM.Holleran CX TV bL k t ►' �► env CD ' -%p. is a"' - a �• � I :. �'-" 6�. �.�- .. . • I. . .�, • ... .,:_..is 1"'" �'; �.- � � .: �' ._: ,,, .• 1, B ;: 1 D ;> . may, I. I All NAW not f � is t: � �; t � :. '�, i �; _� E � ,,� � .1 � � 1: ,I,-•,na r� �� � , �^T YfY•�I.t •IIYhY4e. 1/q� ..._ , -. �"..._._-.�h I 1B r ' B II 1i i' t II ._rI•- .i+wI w,7�� •rr►�r.�..ad .aw.val�u� ... ._. .�...�� t �.r,.�.d pl �n-..tea.,re.res:�" .� �. •---_ua_.r�, �d ut. ,� —w, i_� .R Y•..s 1—..M.+ .rR ar�., j .�.'��� ssY � � m ~'" _ � 4 Irma to . scar E f , B .t I CI 'M-. - ts'�, .++t Ff•�MV�`+sR� - J�tn.s. -4i a.11 .Y� .•..����- s•er•sier��>r'.sF �. YYei fuu•`�+1 Via,. •1. ..-`-,L 9� rm WON - - .r i Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of.8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Co* action test required if_24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R:O.W. use permit. All 4.sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical; or framing shall be covered without an:inspection and approval first. 10. All Garages shall comply with section R302.,6 of the F.B.C. (Fire Separation). I I, Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved_barriers. M303.4.of the F.B:C 12. Water heaters shall comply with section P607.3 of the F:B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms: F.B.C. M.1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C., 18. "Green gypsum board" shall not b' used ' a backer.in-showers or tubs. R702.4:2 F.B.C. . . . . 19. Combindtion-type AFCI breakers are required at all locations requiring an AFCI:type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil=burning heating or appliances or an attached pp garage: They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit_to:unit. This includes all underground_plumbing and electric. 22. All 2016 N.E.C; Codes will be enforced. -23. Tamper- Resistant Rec septacle m accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code, lots shall_ be sodded before final-at.least 10 feet around the structure. f 25. Blower door test and blown in insulation card shall be provided before C.O. 26.. A copy of the energy cacls shall be with permit at.all times j 27.. Copy,of findl insulation report shall he.:proyided with:permit before:tinaL 28.No fence: pool-or screen_enelosure is issued with this oermirk. F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 60'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) r Lennar Homes 3305 Kresterbrooke Ln.2,276 Sgft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,275 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,278.75 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 Public Fee 1% TOTAL $ 2,067.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,194.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,628.00 100.0% $ 7,628.00 1.0% $ .76.28 TOTAL: $ 7,704.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,300.47 i FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION i Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0130i Street: 3305 Kresterbrooke Lane Permit Office: City of 7�ephyrhills City,State,Zip: ,FL, Permit Number:Z� Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ftZ b.Frame-Wood,Adjacent R=11.0 331.33 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ftZ 6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl, U=0.33 87.00 ftZ SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.58 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 I c. U-Factor: Dbl, U=0.33 23.00 ftZ SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.248 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and :Sx4 r � .,.. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance n with the Florida Energy Code. + PREPARED BY: Before construction is completed r . DATE: this building will be inspected for (�F 7--+ compliance with Section 553.908 I herebycertify that this building,as n is Florida Statutes. fY g g d6i 2819mpliance with the Florida Energy Code. alj' OWNER/AGENT: JAN BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification b e air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accords a with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.030 Gin for whole house. 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 r j I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0130 Street: 3305 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) I 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 . 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl, U=0.33 87.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.248 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and TiESx ; this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance "� //, with the Florida Energy Code. PREPARED BY: Dave A>,Ul''ich Before construction is completed -, DATE: this building will be inspected for _ d compliance with Section 553.908 hereby certify that this building,as designed, is in compliance Florida Statutes. ' with the Florida Energy Code. 'd%�j'y : OWNER/AGENT: BUILDING OFFICIAL: i DATE: DATE. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 t I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0130 Street: 3305 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.33 87.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.248 14.Hot water systems 8. Floor Types (1817.0 sgft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat i Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and 0 . this calculation are in compliance with the Florida Energy specifications covered by this , Code. calculation indicates compliance ,j�;'' with the Florida Energy Code. : PREPARED BY: pave AUHM Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 *<, =- :I•"I' hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. oti'.y OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as j certified factory�sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 1 �FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT I Title: 1791A1 sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# i Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: 3540 vinyl windows CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1968 ftZ 0 ft2 Medium 0.85 No 0.9 No 0 22.6 I' ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall Type R-\/,ql,lp Ft In Et In Area R-Mahle Fraction Ahqnr rcafip% 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0.23 0.01 0 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0.23 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior.- Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 2 E=>SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION I # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 j 1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2649 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1 i i i 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name .System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area - Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma X Jun X Jul X Aug �Xj Se Oct Nov Dec Heatin Jan Feb Mar Apr May Jun Jul Au Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .ft. 0 ft2 Oft 0.3 Main Name: Signature: Rating Compant: Date: I' I 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 28.4 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned-floor area(sq.ft.) 6. 1817 d) Room unit/PTAC EER e) Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.388 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.248 14. Heating system: Capacity 28.2 c)Area 7c. 143.3 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 01/15/19 Address of New Home: 3305 Kresterbrooke Lane City/FL Zip: . FL Zephyrhills,FL 33540 1/8/2019 6:53:36 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Buildin Anal $IS Job: 1791A1sf ADS Carrier VW g y Date: 1/1 512 01 9 Entire House , By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 i Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb (°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 I. Component Btuh/ftz Btuh % of load Walls 5.0 9004 33.2 °°ts Glazing 22.1 3488 12.9 nfiltratlon Doors 19.7 726 2.7 wan Ceilings 1.3 2271 8.4 Floors 3.4 6125 22.6 Infiltration 2.1 2882 10.6 Ducts 2616 9.6 Floors Piping 0 0 Humidification 0 0 Glazing Ventilation 0 0 Doors Ceilings Adjustments 0 Total 27113 100.0 Component Btuh/ft2 Btuh % of load Walls 2.4 4378 19.6 Internal Gains Glazing 43.1 6822 30.6 walls Doors 15.4 569 2.6 Ceilings 1.7 3140 14.1 Floors 0 0 0 Ducts Infiltration 0.5 645 2.9 Ducts 2982 13.4 Ventilation 0 0 Internal gains 3750 16.8 Infiltration Blower 0 0 Glazing Adjustments 0 Ceilings Total 22286 100.0 Doors I Latent Cooling Load=2873 Btuh Overall U-value= 0.098 Btuh/ftz-OF Data entries checked. =Ightsc ft- 201&Jan-1510:42:56 ^�^•� w ^� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ment\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: E i Project Summary Job: 1791A1 sf ADS CarrierVW 1 Date: 1/15/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Notes: vinyl windows Design In • • Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24497 Btuh Structure 19304 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27113 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22286 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2339 Btuh Ducts 534 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft2) 1817 1817 Equipment latent load 2873 Btuh Volume(ft') 15431 15431 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 25159 Btuh Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC53OA00300 Cond 25HBC53OA00300 AHRI ref 9154945 Coil FX4DNF031L AHRI ref 9154945 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24140 Btuh Heating output 28200 Btuh @ 47'F Latent cooling 4260 Btuh Temperature rise 26 OF Total cooling 28400 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 31 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigt�tsof[® 2019-Jan-1510:42:56 .-� •-^� ^��-wm Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 �� ...ment\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 1791A1sf ADS Carrier= Date: 1/15/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 22286 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 2873 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 25159 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Sensible capacity: 24140 Btuh 108% of load Latent capacity: 4260 Btuh 148% of load Total capacity: 28400 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 27113 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Output capacity: 22528 Btuh 83% of load Capacity balance: 31 °F Supplemental heat required: 4585 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. wrightsoft® 2019-Jan-1510:42:56 �. •w.Nf��ow�.o�-m Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCK ...ment\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: E