HomeMy WebLinkAbout19-20749 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20749
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
=. PERMIT INFORMATION LOCATION INFORMATION
Permit#:20749 _ Issued: 1/30/2019 Address: 2988 MOULDEN HOLLOW DR
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 256,391.40 Total Fees: 18,396.47 Subdivision: HIDDEN RIVER
Amount Paid: 18,396.47 Date Paid: 1/30/2019 Parcel Number: 25-26-21-0100-00000-0660
CONTRACTOR INFORMATION. OWNER INFORMATION
Name:' LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT
APPLICATION FEES .
BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75
MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28
TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FE °° 36.32 PARK FEES SF 769.56
� I
CJ
Inspections ed
FOOT 2 D ROUGH PLUMB M INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
i
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
t51;5_/t5U_UU2U City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received" Phone Contact for Permitting 813 363 2891
. . . . - - - - - -
rennar Homes,LLC 813.574*.52700
Owner's Name Owner Phone Number
Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
I Fee Simple Titleholder Name N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS [2988 Moulden Hollow Drive LOT# 0660
SUBDIVISION Hidden River Phase One B PARCEL ID# 25-26-21-0100-60000-0660
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONITRR ADDIALT 0 SIGN Q DEMOLISH
P INSTALL REPAIR
PROPOSED USE 0 SFR Q COMM OTHER
TYPE OF CONSTRUCTION 10 BLOCK Q FRAME STEEL
DESCRIPTION OF WORK Single Family Residence Pool Screen Enclosure/Pence
BUILDING SIZE U/R SF 2276 s,FOOTAGE1817 HEIGHT 1 Story
a I F-1r-ff—r-T--r-ff—F—F— X�.a . a . . . . . . IT
U_/ BUILDING VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL is --- AMP SERVICE FX_1 PROGRESS ENERGY W.R.E.C.
J 7
PLUMBING
MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING 0 SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA. OYES Do
. . . . . .. . .. .. .. . . . . . . . .
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 14600 W.Cypress St.Ste,200,TfAa,FL 33607 1 License#. [TGC1518166
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN LZI N_J
E
Address 11034 Skipper Road, Tamp/, FL 3361 �� License# FC13005408
'PLUMBE.R COMPANY Bayonet Plumbing, Heating & AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN
Address P.O. Box 5308, Bayonet, FLA4674X- 08 License# FcFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N J FEE CURREN L_y LN_j
Address P.O. Box 5308, Bayonet, FL64671-5308 License# I CAC058062
OTHER COMPANY C Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
AddressI 14211 Shoal Line Blvd, Sprinf Hill, FL 34607 License#
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&i dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&I dumpster..Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction.
94—i II II I I I I V V a a 9 , V . . . 0 a a 1 1 a I I 1 9 1 4-3-4.
Directions.
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2600,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE O und that this permit may be subject to"deed restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibilityfor compliance with any
applicable deed restrictions. 1. '
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: if the owner has hired a contractor or
contractors to undertake work, they may be required to,be licensed in accord oncevvith state and local regulations. If the
contractor is not licensed as required by |aw, boththe owner and contractor may be cited fora misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasc6 County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contnantoro, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly Uoanmad and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT ANDRESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing bVi|dingo, or expansion of existing buildings, as specified in Pasco County C>njinoDca number 89-07 and
80-07. as amended. The undersigned also'understands, that such feeo, as may be dua, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" Vr final power release. |f the project doeonctinvolveomarbfioeb* ofocouponcyor
final power re|aaoa, the fees must be paid priorto permit issuance. Furthermore, if Pasco County \8habar/Gevver Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances,
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,as amended): |f valuation of work\e$2.5OO.ODormore, |
certify that |, the app|inaOt, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. |f the applicant \asomeone
other than the"owner", | certify that | have obtained a copy of the above described document and p[onnimo in good faith to
deliver itto the"owDer' prior tocommencement.
CONTRACTOR'S/OWNEWS ^4FFYDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable |ovYs regulating connt[Votion, zoning and land development. Application is
hereby made to obtain a pannii to do xxo[h and installation on indicated. | certify that no work or iDetaUadion has
commenced prior to issuance of permit and that all work will be performed to meet standards of ail laws regulating
construction, County and City codes, zoning nagu|oUona. and land development regulations in the jurisdiction. | also
certify that | understand that the regulations of other government agencies may apply to the intended xvork, and thdt it is
my responsibility to identify what actions | must take tnbeincompliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Boyheado, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
' Southwest Florida VVahar Management District-Wells, Cypress Bayheodo, Wetland Anaaa, Altering
VVate[cnUnoeo.
- Army Corps ofEnginenro-GmcuwoKa' Docks, Navigable Waterways.
- Department of Hoa|Ml @ Rehabilitative 8arV|oao/EnvinJOrnanta| Health UOit-We||o, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation AUthority-RunvVaye.
\ understand that the following restrictions apply to the use offill:
- Use of fill io-not allowed in Flood Zone Wr unless expressly permitted.
- if the fill material is to be used in Flood Zone "/Y'. it is understood that drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State ofFlorida.
- If the fill rnoteha| is to be used in Flood 20De "N' in connection with a permitted building using ata[n vvmU
construction, | certify that fill will be used only tofill the area within the stem wall.
' If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent propmrtiea, the owner may be cited for violating '
the conditions of the building permit issued under the attached permit application, for lots |eoe than one (1)
acre which are elevated by fill, on engineered drainage plan is required.
|f( am the AGENT FOR TBE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. | understand that separate permit may be required for electrical work,
p|Unnbing, aigno, vve||o, poo|a, air ooDdiUoning, gas, or other installations not specifically included in the application. A
penn� issued shall beconn�umdbobea license-to proceed with the xvorkand not ao authority hz violate, cancel, alter, o,
set ae!daany provisions of the technical codes, nor shall issuance ofm permit prevent the Building Official from thereafter
requiring a correction of errors'in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of*six(6) months after the time the work iacommenced, An extension
may be requested, in vvhtng, from the Building Official for a period not to exceed ninety (BO) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOURLENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
OWNER"mAGENT ~~...~~C.^~.
Subscribed and swom-to.(or affirmed)h re me this Subscribed and s to(or affirmed)before me this
a�n-19 As
as identification. as identification.
ma�Pumm Notary Public
��98537 Commission N FF98537
Commission No. mm nn o
ElisoaM.Holleran EhsoaM.Holleran
Lennar Homes-2988 Moulden hollow dr-2,376 sq ft
Column ts
SO. FEET: PRICE
MAIN OR LIVING: 2,276 $ 112.65
y OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 30.00
DRIVEWAY1 $ 45.00
BUILDING: $ 1,426.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,062.50
TOTAL $ 2,062.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
-FIRE DEPARTMENT FEES
PLANS TOTAL: na
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35 li
TOTAL: $ 553.35
i
SUB-TOTAL $ 6,189.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,728.00
100.0% $ 7,728.00
1.0% $ 77.28
TOTAL: $ 7,805.28
T I F'S : $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL:' $ 18,396.47
Jacqueline Boges
From: Jordon Davis (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, February 6, 2019 3:23 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 2988 Moulden hollow' r by#20749
##- Please type your reply above this line -##
Your request (#262058) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/262058
.......................................................................................................................................................................................................................................................................................................................................................................................
Jordon Davis (City of Zephyrhills Support )
Feb 6, 1 :22 PM MST
WO#765397 created to install new meter to the property.
Best Regards,
Jordon I FATHOM Support
...................................................................................................................................................................................................................................................... ...............................................................................................................
�( 4 Jordon Davis (City of Zephyrhills Support )
`-- Feb 5, 4:23 PM MST
Account has been added and is being mapped account number is 0000889145-003124224
Best Regards,
Jordon I FATHOM Support
........................................................................................................................................................................................................................................................................................................................... ..........................................
t_ i Jacqueline Boges
i
- ' Feb 5, 2:38 PM MST
s e r v i c wW?8 S.R1 1ourcIZW rd-W
i
This email is a service from City of Zephyrhills Support .
1
Jacqueline Boges
From: Jordon Davis (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, February 6, 2019 3:23 PM
To: Jacqueline Boges
Subject: [FATHOM] Re:2988 Moulden hollow dr by#20749
##- Please type your reply above this line -##
Your request (#262058) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/262058
............................................................................................................................................-.........................................................................................................................................................................................................................................
Jordon Davis (City of Zephyrhills Support )
Feb 6, 1:22 PM MST
WO#765397 created to install new meter to the property.
Best Regards,
Jordon I FATHOM Support
.................................................................................................................................................................................................................................................................................................................................................................................
Jordon Davis (City of Zephyrhills Support )
—; Feb 5, 4:23 PM MST
Account has been added and is being mapped account number is 0000889145-003124224
Best Regards,
Jordon I FATHOM Support
...................................................................................................................................................................................................................................................................................................................................................................................
I .F: Jacqueline Boges
--- Feb 5, 2:38 PM MST
service 2988 Moulden hol]ow drfbp,#-2OrZ:49
This email is a service from City of Zephyrhills Support .
1 �;
PASCO COUNTY, FLORIDA
Permit No. 7—QU
Date Permitted
Builder Name/Owner Name ,�I/lQv-� Control#
County Parcel No. ZS`Zb-Z,l— '�!�(�D(�-!)(v�Oa SubDiv:
Address/Location 94 619 /VL de17 u 0) I2-
ClassiflcationlType of Use 6/ [ 2, Z-
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
Exempt ❑Yes [] No How Determined
Impact Fee Amount 3.2 Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ `7
(057) Mobile Home
(058) Other Residential
23) Collection Fee
Exempt d Yes ❑No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
I ,
Zone TOTAL AMOUNT $
Exempt ❑Yes No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility.Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID,AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of•a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for some.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Lennar Homes 2988 Moulden Hollow Dr.2,276 Sqft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,431.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,067.50
Public Fee 1%
TOTAL $ 2,067.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,194.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,628.00
100.0% $ 7,628.00
1.0% $ 76.28
TOTAL: $ 7,704.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,300.47
Single Family Dwelling
Plan Review Comments
1: F.F.E:.shall be a minimum of 8 above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3-of the F.B.C.
I Compaction test required if.24"or more of fill dirt.is brought in at any one place.
4. Tie in survey required before pouring.concrete.
5. Driveways require a R:O:W. use permit. A11.4 sides of driveway thru the sidewalk shall-Have
expansion material.
6. All setbacks shall be met:
7. All.property markers shall be uncovered and marked.at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric,plumbing,mechanical; or fratriirig shall be covered without an inspection and
approval first:
10. All Garages shall comply with.section R3016 of the F.B.C..(Fire Separation).
11. Appliances shall not be installed in a locationwhere subject to mechanical damage unless
protected by approved barriers. M303.4:of the F.B.0
12. Wate'r.heaters shall comply with section P607,3 of the F.R.C.
13.Foundation supports for A/C units shall be raised at least 3" above finished grade. M130.8.1
14. Return air.in all bedrooms. F.B.C. M.1620.4
15. Smoke detectors are to be installed in accordance with R31-3.1 of the F.B.C.
16, All.glazing requirements are to be in accordance'with R308:4-of the F.B.C.
17.All means of egress are,to,be in accordance with R311 of the F.B.C.
18. "Green gypsum board shall riot be used-as a backer in:showers or tubs. R702.4:2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring'an AFCI type breaker.
20. Carbon monoxide alarms will be required in.riew.construction that uses fossil-burning heating
or appliances or an attached garage; They shall be installed in accordance with the F.B.C;
21. All plumbing, mechanical, and.electrical shall be separate from unit.to.unit: This includes all.
underground plumbing and electric.
22.. A112016 N.E.Q. Codes will be enforced:
23. Tairiper= Resistant Receptacles in accordance with 406.11 of the 2016 NEC
24: In accordance with the Land Development.Code,-lots shall be sodded before final.at least 10
feet around the structure:
`25.Blower door test shall be provided before.C.O.
26.A cotes Of ever y eacls shall be with-Hermit at-all times.
27 Cotiy of final insulation,report shall be.:provided with:permit before:r1naL
28:No fence,:Hoo[6r screen enclosaie is:issued with-this permit
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 6fl'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
1
Single Family Dwelling
Plan Review Comments
1: F.F.E. shall be a min imum.of 8 above the road-elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F:B.C:
3. Compaction:test required if 24"or more of fill_dirt is brought in at any one place.
4. Tie in-survey required before pouring concrete.
5. Driveways require a R:O:.W.use permit. All_4.sides of driveway.thru-the sidewalk shall have
expansion material.
6. All setbacks.shall be met:
7. All property markers shall be.uncovered and marked at time of first.hispeclion.
8. All A.D.A. requirements shall be met.
9-. No electric, plumbing,mechanical; or framing shall be.covered without an inspection and
approval first.
10. All. Garages shall comply with section R302,6 of the F.B.C..(Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical_damage unless
protected by approved barriers. M3014.of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at lea9t.3" above finished grade. M13.08.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are-to be 'installed in accordance with R313..1 of_theT.B.C.
16, All glazing requirements are to be in accordance with R.308.4 of the F.B.C.
17. All means:of egress are to.be in accordance with R311 of the F.B.C. . .
18: "Green gypsum board" shall notbe used as a backer in-showers or tubs, R702.4.2 F.B.C.
19. Combination-type AFCI breakers are-required at all locations requiring an AFCI type breaker.
20. Carbon-monoxide alarms will be required in new construction that uses fossil=burning heating
or appliances or an attached garage: They shall be installed in accordance with the F.B.C:
21. All plumbing,mechanical, and electrical-shall be separate from unit to unit: This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced.
23.-Tamper=Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 .
24. In accordance with the Land Development Code, lots shall be sodded before final:at least 10
feet around the structure.
25.Blower door test shall be provided before:C..O-.
26.. A cony ofthe enerky edcls shall be with permit at all times
27.foyy.of rndl insulation report"shall be.:pioWded with:permit before.rinaL
.28:No fence::pool or screen enclosure is:issued with this permit- .
,i
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 6a'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
-�•�ii •'i••.•'•Wit. ..�.} ... - a-^ >ti:,�� tJ`' .. �� ..�••
+:�'•• .•., "••/ ^ fy/� /ice' �
r ,iN +"
w ..
co
Not
Mddw
4Ltyyy •:• - -�
° ,,••' i
CITY OF " NOTICE / / BUILDING
ZEPHYRHILL•S DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT REMOVE
Ap R AT PERMIT
THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job
will be accepted.
1A, 2! A
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,_lath,earth 780-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample time to approve
the installation. e'
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR
PASCO COUNTY
P/A SC( BUILDING CONSTRUCTION SERVICES
l -1 ✓ 8731 Citizens Drive Date:4/30/2019
COUNTY FLORID Suite 230
Oi,m.4 Smc«.Yinwvr Pukes. New Port Richey, FL 34654
727-847-8126
�cak IMUT A PEIRMT
Receipt M 1852374
FEE DESCRIPTION ACCOUNT CODE. UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 1.00 1453365 $45.00 $45.00 1852374 4/30/19
Waste Single Family
TOTALS:- $45.00 $45.00
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1852374 Check 01212929 MLARNOLD BCCCP59W 04/30/2019 $45.00
Total Payments: $45.00.
Pavor Address Phone
Lennar Homes, LLC
Comments:
2988 Moulden Hollow DR 1
While you will be paying your bill with Pasco County Building Construction Services,the-full amount of the credit card or a-check fees,NOT shown above,Is
collected by First Billing payment servires.
I
MyReports/reports//PASCOPROD/PASCO/ReceiptAA_V7.rpt 4/30/2019 Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0066
Street: 2988 Moulden Hollow Drive Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number: V7 Y9
Owner: Lennar Homes Jurisdiction:- 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1817.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.33 87.00 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.33 23.00 ft2
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
i
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.248 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1817.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS
Total Baseline Loads: 58.15
hereby certify that the plans and specifications covered by Review of the plans and `CST.q
this calculation are in compliance with the Florida Energy specifications covered by this O r r ,.
' % �_
Code. calculation indicates compliance '��i}i � -- �.?, s+. ...,
with the Florida Energy Code. '�- rtrii: `�.-•;:.• ;��`�'
PREPARED BY: gave Aupich Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification b he air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accorda a with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0066
Street: 2988 Moulden Hollow Drive Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ftz
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c. R= ft2
11.Duct
s R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.33 87.00 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.33 23.00 ft2
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.248 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 EF:0.950
b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079
Total Proposed Modified Loads: 56.95 PASS
Total Baseline Loads: 58.15
i
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this APQ r=_
Code. calculation indicates compliance
with the Florida Energy Code. ti'' rmr`, ,:;: ;;•� 1`O`
PREPARED BY: Dave Aupich Before construction is completed W .
DATE: this building will be inspected for
compliance with Section 553.908
Florida Statutes.
I hereby certify that this building,as designed, is in compliance
c�.
with the Florida Energy Code.
-OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as j
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
r , i
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION i!
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0066
Street: 2988 Moulden Hollow Drive Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.33 87.00 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.33 23.00 ft2
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft. !
Area Weighted Average SHGC: 0.248 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1817.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS
Total Baseline Loads: 58.15
i
hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
f{ ti,�ii�i" .�, . � •`��ti O.
PREPARED BY: Dave l.G�pich Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I herebycertify that this building,as designed,is in compliance Florida Statutes. . -
fY 9� 9 P
with the Florida Energy Code. OD;W>r �3
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). %
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house.
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
_ I
FORM R405-2017. INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 1791A1 sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1817 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: 3540 vinyl windows
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1817 14536
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes 1
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 ___ 0.3 0 0.7
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
i
1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
I
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1817 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4
II
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0
2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0.23 0.01 0
3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0.23 0.01 0 !
4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0
5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0
6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0
7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
2 E=>SE 4 Vinyl Law-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
3 S=>SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None
5 W=>NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 427 ft2 427 ft2 42 ft 8 ft 1
INFILTRATION
# Scope Method SIA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2649 7
i
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1
I
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4
r '
FORM R405-2017. INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Feat Cool
1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
i
CoolingJan Feb Mar [ ]A r I jMa rl Jun X Jul rl
Au rj
Se [ Oct H
Nov Dec
Heatin Jan Feb f X�Mar [ ]APr MaY Jun r i Jul AuSep [ Oct Nov X Dec
Ventin Jan Feb X Mar [X]A r May Jun Jul Aug Se [[[XXX Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
I
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main
Name: Signature:
Rating Compant: Date:
k
I
1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4
2017.EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Attic/Main
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13.Cooling system: Capacity 28.4
a)Split system SEER 15.0
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1817 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.388
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.248 14. Heating system: Capacity 28.2
c)Area 7c. 143.3 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8.Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other 8.50
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood,raised(R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10B1. 11.0
2. Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit I'
d) Radiant barrier installed 11 d. No e) Multizone heating credit j
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed c de compliant features.
Builder Signature: Date: 01/15/19
Address of New Home: 2/8Moulden Hollow Drive City/FL Zip: , FL Zephyrhills,FL 33540
1/8/2019 6:53:36 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Building Anal Job: 1791A1sf ADS canner vWl
g Y$I$ Date: 1/15/2019
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%)' 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range ff) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft2 Btuh % of load
Walls 5.0 9004 33.2 °�
Glazing 22.1 3488 12.9 nfiltration
Doors 19.7 726 2.7 Wail
Ceilings 1.3 2271 8.4
Floors 3.4 6125 22.6
Infiltration 2.1 2882 10.6
Ducts 2616 9.6
Piping 0 0 Floors
Humidification 0 0 Glazing
Ventilation 0 0 Doors Ceilings
Adjustments 0
Total 27113 100.0
• • •
Component Btuh/ft2 Btuh % of load
Walls 2.4 4378 19.9 Internal Gains
Glazing 43.1 6822 30.9 wall
Doors 15.4 569 2.6
Ceilings 1.7 3140 14.2
Floors 0 0 0 i . Ducts
Infiltration 0.5 645 2.9
Ducts 2982 13.5
Ventilation 0 0
Internal gains 3520 16.0 Infiltration
Blower 0 0 Glazing
Adjustments 0 ceilings
Total 22056 100.0 Doors
I
Latent Cooling Load= 2673 Btuh
Overall U-value= 0.098 Btuh/ft2-°F
Data entries checked.
- wrightsoft- 2019-Jan-15 10:43:57
r Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..ment11791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SW
r
I'
Project Sl1rY11�17a Job: 1791A1 sf ADS CarriervW1'
J •J Date: 1/15/2019
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project I • •
For: Lennar Homes
Notes: vinyl windows
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24497 Btuh Structure 19074 Btuh
Ducts 2616' Btuh Ducts 2982 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 27113 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 22056 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2139 Btuh
Ducts 534 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ftZ 1817 1817 Equipment latent load 2673 Btuh
Volume (ft') 15431 15431
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 24729 Btuh
Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC53OA00300 Cond 25HBC53OA00300
AHRI ref 9154945 Coil FX4DNF031L
AHRI ref 9154945
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 24140 Btuh
Heating output 28200 Btuh @ 470F Latent cooling 4260 Btuh
Temperature rise 26 OF Total cooling 28400 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point= 31 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Fk- wrightsoft- 2019-Jan-1510:43:57
- Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACCk ..ment\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SW
Manual S Compliance Report Job: 1791A1sf ADS Carrier VW,
Date: 1/15/2019
Entire House By: Dave
Bayonet Plumbing Heating and Air
--Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 22056 Btuh Entering coil DB: 75XF
Outdoor design WB: 77.3°F Latent gain: 2673 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 24729 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Sensible capacity: 24140 Btuh 109% of load
Latent capacity: 4260 Btuh 159% of load
Total capacity: 28400 Btuh 115% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 27113 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Output capacity: 22528 Btuh 83% of load Capacity balance: 31 °F
Supplemental heat required: 4585 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1000 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
-F- wrightsoft® 2019-Jan-15 10:43:57
AW*•�aaww -,�-, Right-Suite®Universal 2018 18.0.16 RSU05714
Page 1
ACC ...merit\1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SW