Loading...
HomeMy WebLinkAbout19-20750 CITY OF ZEPHYRHILLS 5335-STH STREET (813)780-0020 20750 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20750 Issued: 1/30/2019 Address: 3317 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,205.80 Total Fees: 18,478.97 Subdivision: HIDDEN RIVER Amount Paid: 18,478.97 Date Paid: 1/30/2019 Parcel Number: 24-26-21-0100-00000-1310 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,312 SQ FT APPLICATION FEES -BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PEU-M—BING FEE 207.00 MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI '1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 r� Inspections Redu re FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney ' before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 'CONTRACTORS SI RE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes 3317 Kresterbrooke Lane-2,372 sq ft e o umn ts SQ. FEET PRICE MAIN OR LIVING: 2,372 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 i OTHER: - $ - VALUATION $ 267,205.80 FEE SHEET $ 1,380.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,482.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,145.00 TOTAL $ 2,145.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:j $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,272.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,478.97 Jacqueline Boges From: Jordon Davis (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com> Sent: Wednesday, February 6, 2019 2.49 PM To: Jacqueline Boges Subject: [FATHOM] Re:3317 kresterbrooke lane bp#20750 ##- Please type your reply above this line -## Your request (#262072) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/­reciuests/262072 ........... .......... .......... ................ .............................................................. ............. ......................... ..................................... 1 Jordon Davis (City of Zephyrhills Support ) Feb 6, 12:49 PM MST WO#765371 created to install new meter to the property. Best Regards, Jordon I FATHOM Support ................. ........................... .............. .......... .....................- ......................... �-D ,- Jordon Davis (City of Zephyrhills Support Feb 5, 4:42 PM MST Account has been added and is currently being mapped. Account number is 0000889145- 003124239 Best Regards, Jordon I FATHOM Support ............ ........... .......... .............. ........... ............................ T Jacqueline Boges Feb S, 3:07 PM MST servicSI& L,1 are, r,@C11l<!1-ii 1 Xgpl#-2-07:50 t1lar This email is a service from City of Zephyrhills Support FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Carrier VW Builder Name: Lennar Homes 013 i Street: 3317 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: 'Zo-7STD Owner. Lennar Homes ,jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.33 101.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.246 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: `58.83 PASS Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans and Ork1E STgr I, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: 'Dave Aupich Before construction is completed DATE: this buildingwill be inspected for p compliance with Section 553.908 herebycertify that this building,as designed, is in c liance Florida Statutes. fY Energy 9 9 P with the Florida Ener Code. OWNER/AGENT: JAN 1 2649 BUILDING OFFICIAL: DATE: DATE: I - Compliance requires certification by thegir handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. j -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-201 7 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Carrier VW Builder Name: Lennar Homes 0131 Street: 3317 Kresterbrooke Lane Permit Office: City of ZephyrhjIls City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.33 101.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.246 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.NIA R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 58.83 PASS Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ,/ with the Florida Energy Code. PREPARED BY: Dave AGE ch Before construction is completed , DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. r with the Florida Energy Code. Q1j' OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R1405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Carrier VW Builder Name: Lennar Homes 0131. Street: 3317 Kresterbrooke Lane Permit Office: City of ZephyrhiUs City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.33 101.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEERA5.50 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.246 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 58.83 PASS Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans and k '41 I this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: gave AGGIpich 'Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 *<. ,�. I herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9 95 with the Florida Energy Code. aD W6: OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1941A1 sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Vinyl windows CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 master 210 1680 No 2 1 1 Yes Yes Yes 2 family rm 341 3171.3 No 0 1 Yes Yes Yes 3 cafe 161 1288 No 0 1 Yes Yes Yes 4 kit 182 1692.6 Yes 0 1 Yes Yes Yes 5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes 6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes 7 bath2 61 488 No 0 1 Yes Yes Yes 8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes - 9 o wic 104 832 No 0 1 Yes Yes Yes 10 privy 24 192 No 0 1 Yes Yes Yes 11 o bath 117 936 No 0 1 Yes Yes Yes 12 laundry rm 100 800 No 0 1 Yes Yes Yes 13 foyer 148 1376.4 No 0 1 Yes Yes Yes 14 hall 43 344 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 0 0 1 1 I 2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 0 0 1 3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 0 0 1 4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft2 1 0 0 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS i # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 ___ 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 1 0 0 8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 0 0 1 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 1 0 0 11SIab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0 12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 It 0 147.5 ft2 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood 3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood 6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood 7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood 8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood 9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood I, 11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood 12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood 13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood 14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood 111 5/201 9 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS ve Ornt Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 13 N=>NE Garage Frame-Wood o wic 11 12 0 8 0 96.0 ft2 0 0.23 0.01 0 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 _16 N=>NE Garage Frame-Wood laundry rm 11 7 5 8 0 59.3 ft2 0 0.23 0.01 0 17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 18 W=>NW Garage Frame-Wood foyer 11 16 4 9 4 152.4 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None i 2 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 5 Metal Low-E Double Yes 0.58 0.32: N 33.3 ft2 2 ft 0 in 0 ft 6 in None None 4 E=>SE 7 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 5 E=>SE 8 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 6 N=>NE 10 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 4 ft 2 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 416ft2 416ft2 43.7ft 8ft 1 I 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6 ! i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION I # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000376 1908.7 104.79 197.06 .2844 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1050 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1 TEMPERATURES i Programable Thermostat:Y Ceiling Fans: CoolingJan Feb [[ ]]Mar [ ]A r [ j May rl Jun rl Jul X]Aug Se [ ]Oct [[ ]]Nov [[ ]]Dec Heatin Jan Feb [X]Mar [ ]Apr [ May Jun Jul ]Au Sep [ ]Oct [X]Nov [X]Dec Ventin Jan Feb X Mar [X]A r [ May Jun Jul [ ]Aug Se [X]Oct [X]Nov [ ]Dec I i 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 1 st Floor Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 2nd Floor Name: Signature: Rating Compant: Date: i I 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 6 of 6 i I I r 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/family rm 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1936 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.383 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.246 14. Heating system: Capacity 34.6 c)Area 7c. 157.3 a)Split system heat pump HSPF 8.5 b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise,a new EPL display card will be completed based on instal code compliant features. Builder Signature: Date: 01/15/19 Address of New Home: 3317 Kresterbrooke Lane City/FL Zip: FL. FL ZeJ2hyrhills, FL 33540 1/15/2019 9:53:56 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 T I Building Anal Job: 1941A1sf ADS CarrierVW g YSIS Date: 1/15/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftz Btuh % of load Walls 5.2 8237 30.1 acts Glazing 20.9 3262 11.9 wall Doors 23.5 466 1.7 Infiltration Ceilings 1.3 2429 8.9 Floors 3.5 6726 24.6 Infiltration 1.7 3056 11.2 Ducts 3221 11.8 Hlumidification 0 0 Glazing Floors Other., Ventilation 0 0 Ceilings Adjustments 0 Total 27396 100.0 Component Btuh/ftz Btuh % of load Walls 2.8 4367 16.8 wall Glazing 49.0 7639 29.3 Internal Gains Doors 18.4 365 1.4 Ceilings 1.7 3358 12.9 Floors 0 0 0 Infiltration 0.4 684 2.6 Ducts 3628 13.9 Ventilation 0 0 Ducts Internal gains 6030 23.1 Glazing Blower 0 0 Infiltration Adjustments 0 Total 126071 100.0 other Ceilings i Latent Cooling Load=4280 Btuh Overall U-value= 0.096 Btuh/ftz-°F Data entries checked. wrightsoft- 2019-Jan-15 09:46:57 ^��•� wu-+�^rw Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ipment\1941 sf ADS template VW 3ton Carrier.rup Cale=MJ8 Front Door faces: E i ' Project Summary Job: 1941A1 sf ADS Carrier VW J •J Date: 1/15/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Notes: vinyl windows Design Inf• • Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24176 Btuh Structure 22443 Btuh Ducts 3221 Btuh Ducts 3628 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) � Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27396 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26071 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3619 Btuh Ducts 660 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1936 1936 Equipment latent load 4280 Btuh Volume(ft3) 16360 16360 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30351 Btuh Equiv.AVF(cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade PERFORMANCE 15 HP Trade PERFORMANCE 15 HP Model 25HBC537AO030 Cond 25HBC537AO030 AHRI ref 10487322 Coil FX4DNF037L AHRI ref 10487322 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 29750 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5250 Btuh Temperature rise 26 °F Total cooling 35000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm I Air flow factor 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point=27°F Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2019-Jan-15 09:46:57 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..ipment11941 sf ADS template VW 3ton Carrier.fup Cale=MJ8 Front Door faces: E i Job: 1941A1 sf ADS Carriervw' Manual S Compliance Report Date: 1/111 512 0 1 9 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26071 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 4280 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 30351 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29750 Btuh 114% of load Latent capacity: 5250 Btuh 123% of load Total capacity: 35000 Btuh 115% of load SHR: 85% Heating Equipment i Design Conditions Outdoor design DB: 30.8°F Heat loss: 27396 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26710 Btuh 97%'of load Capacity balance: 27 °F Supplemental heat required: 686 Btuh Economic balance: -99 °F i I Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. t Wrightsofta 2019-Jan-15 09:46:57 �, •rrt•H he,w•w-,� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ipment\1941 sf ADS template VW 3ton Cartrer.rup Calc=MJ8 Front Door faces: E PASCO COUNTY, FLORIDA PermltNo. .20'760 Date Permitted Builder Name/Owner Name Control W County Par..cel No. SubDIV: Address/Location kves" ke- ClassiflcatlonlType of Use cam. 2-, 3?Z TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2t 3 7 Z Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. 3��e 3 2 Zone No. TAM SCHOOL IMPACT FEE Z� Account (056) Single-Family Detached House Amount $ D 9 .(057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ '7(05• � Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount, RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY i Lennar Homes 3317 Kresterbrooke Ln.2,372 Sqft I Column SQ. FEET PRICE MAIN OR LIVING: 2,372 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,205.80 FEE SHEET $ 1,380.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,487.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,150.00 Public Fee 1% TOTAL $ 2,150.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 j IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 I' SUB-TOTAL $ 6,277.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,628.00 100.0% $ 7,628.00 1.0% $ 76.28 TOTAL: $ 7,704.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,382.97 i Single Family Dwelling Plan Review Comments 1: F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. 2. Lots shall-be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.b..W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A.requirements shall be met. 9: No electric,plumbing, mechanical; or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11.. Appliances shall not be installed in a location where subject to mechanical damage unless protected by' approved barriers. M303.4.of the F.B.0 12:Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports.for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be 'installed in accordance with R313.1 of the F.B.C. 16.. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means,of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall riot-be used as a backer.in showers' or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker: 20. Carbon monoxide,alarms will be required in new construction that uses fossil=burning heating or appliances or an attached garage: They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C:. Codes will be enforced. 23. Tamper= Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with.the Land Development Code, lots shall be sodded before final at least 10 feet around the structure: 25. Blower door test and blown in insulation card shall be provided before C.O. 26 A cony of the energy cacls shall be with permit at all times. i 27 Copy of final insulation report shall be.-prMded with permit before:final 28:No fence,pool or screen.Mclosaie -is.issued with this'pern:ft. i F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 6"'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) t5'I;5-1bu-UU2U City of Zephyrhills Permit Application F�813-780-0021 Building Department r | Date Received Phone Contact for Permittin, 813 363 2891 \ Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner Phone Number Foe Simple Titleholder Name Owner Phone Number . Fee Simp|o Titleholder Address N/A JOB ADDRESS F3317 Kresterbrooke LaneL T# ' Hidden River PhasePARnEL|D# 24-26-21-0100-00000-1310 (OBTAINED FROM PROPERTY TAX NOTICE) �UBo|V|G|oN WORK PROPOSED mmvcomsm 8DCKA�' [---� S|GN F--1 �—� DEMOLISH |NSlALL �_] REPAIR PROP' snUSE GFR F--1 COMM [---1 OTHER TYPE bFComSTRVnTiO0 BLOCK [—� FRAME �---1 �T�EL F--} �—� �---� `--� DESCRIPTION OF WORK ily Residence Pool Screen Enclosure Fence BUILDING SIZE I U/R SF 237.4 1 so.FOOTAGE HEIGHT 1 Story . ~ ' U|�D|NG OB. VALUATION OF TOTAL CONSTRUCTION ELECTRICAL ��PG�RV|oE F�'� ` PROGRESS F--1 Ni��E.C� �~—' ^--� ' �my UPLUMBING | ~--' U»� �MECHANICAL VALUATION OF MECHANICAL INSTALLATION / [—�l �--l6AS �� � ROOFING SPECIALTY aP��h�LTYF--� OTHER ^---' ��� --- ----' | ' �—� F--1 . ` FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA V UYEG / NO �� �� | BUILDERCOMPANY SIGNATURE REGISTERED L_12�LNL_| FEEcunnsN Address14600 FL 3E= L�onoe# =Ed ELECTRICIAN / SIGNATURE o ! x�Jdmso 11034 Skipper Road,Tampa, FL 33613 Lic,nsm# PLUMBER COMPANY =BaYOnet Plumbing, Heating &AC, Inc SIGNATURE LY2 N_ pescunneN Address Linnnue# MECMAN|oAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE L_I/ NL_J pssCunnsN L_YLNL—J Address License OTHER COMPANY C Sterling Quality Roofing, Inc 0GN/TUIR,E REGISTERED L_Y/ N_ I FEEo»n»sx L_YlN_J Address 14211 Shoal Line Blvd, Spring Hill, FL 34607 License# Fc cCO57991 ! � xuvmwwxxmxuowuuonmxw0000xxnunmnouomoonnxuuomxxmummxnxmowuxoxwxxunmx RESIDENTIAL Attach(2) of Building Plans;(1)set n[Energy Forms;R-O4wponnit for new construction, Minimum ten(1O)working days after submittal date. Required onsita.Construction Plans.0onnvater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.. Minimum ten(1U)working days after submittal date. Requi,edunaiva. Construction Plans,Goonnwoter Plans v/Silt Fence installed, � Sanitary Facilities&I dump§ter.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. °^**PROPERTY SURVEY required for all NEW construction. Fill out application completely. Owner&Contractor sign back of application,notarized |,over$o6Vo.a Notice of Commencement inrequired. (VC upgrades over$7moo) � Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy mf contract required) Ramof�ifshingles Sewers Service Upgrades A/C Fennos(P|ot/8um*y/Footogo Driveways-Not over Counter if on public roadways-needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR, RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements.may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated: I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes; zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterPvVastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: -Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood ,Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area; I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall-become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)bAfore me this Subscribed and swot o(or affirmed)before me this yo-Jan-i� by Ashlee Callahan 08-Jon-19 by shlee Callahan Who is/are personally known to me o hasihave predased Who is/are ersonaify known to me or has/have PFedwee# s identification. as identification. Notary Public Notary Public Commission No. FF98537 4o: mmission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary tvped,printed or stamped Name of Notary typed,printed or stamped " :m4 ICAM7�IUOVPDISO ;7 B2oI 4 L -W&ON L-WO.0 .r.F•.%A ELJ r•,-. _, „ "�" 'a _---_—_mTib�,.m,�.., --- ' A. r13 do k . ���.. L_ MIT FAI I 3, ' Filk �V r 1,WA 28 1 �6 LAD_ _ ___ 283 G- m__ Fz+�' •-.� ev m. Pii!iP+P - _ - (••liew� � ®..®'rrP u!W �..s:«.wa.._. .rr..e•c—maa. +-...+� �!., FF EL 27 T+�y{ " : st + 10 A` - .rr®r�� ;`a �� �y;s s;:ra•+�r��—�� ��"�•� re�i�+e s�! �. —. �,�, TI�T3i.• �' . : a ! FFELPL 116 .rye- ...�:..r i+e wriLAAJ _..-..•b "'"4���^^^ : _ YM urt' eie11�►etfls ——.M-w- - cu,v.4Y 'XL•33+e®aveY .'cmw.�!`GiKY M®F!4R•!!!r - ,���_.x .��w�A•i�!!`.m. . 28 . .� �' �. �►" F — �•.•- 'i r ., � ..._ .'4a .. +ems "-�.� "�t ' - : :' j.�y � ,: :- '. . . . -'`!'3 W€ .- pi"!' .:. ar'Ic Ji' ..._. :- VA An; PASCO COUNTY BUILDING CONSTRUCTION SERVICES PLSG'�-` 8731 Citizens Drive Date:4M0/2019 COUNTY FLORIDAK- Spite 230 New Port Richey,FL 84654 727;.847-8126 NOT A PERMT Receipt#: 1852404 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1453415 -$45.00 $45.00 1852404 4/30/19 Waste Singe Family TOTALS:. $46.00 $46.60 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt.Date Amt Paid! 1852404 Check 01212939 MLARNOLD 9CCCP59W 04/30/2019 -$4,5,00 Total Payments: $46.00- LaM Address- Phone Lennar Homes, LLC Comments: 0 3317 krestetbrooke LN JL/ " FJ While you will be paying your bill with Pasco County Building Construction Services,the full amount of-the credit card or e-check fees,NOT shown above,Is collected by First Billing payment services; MyReport'streports//PASCOPROD/PASCO/ReceiptAkV7.rpt 4/30/2019 Page 1 of 1