Loading...
HomeMy WebLinkAbout19-20752 CITY OF ZEPHYRHILLS ' 5335-8TH STREET (813)780-0020 20752 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20752 Issued: 1/30/2019 Address: 3306 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,656.40 Total Fees: 18,478.97 Subdivision: HIDDEN RIVER Amount Paid: - (I Date Paid: ,- Parcel Number: 24-26-21-0100-00000-0950 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT APPLICATION FEES BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00 MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections a uired FOOTER 2ND ROUGH PLUMB MISC INSULA I N EILIN FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Rennspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. n1fluA 6w-, CONTRACTORS SIGNATURE PERMIT OFFIjFA PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Building Department Date Received Phone Contact for Permittin 813 363 I —A I .- - - =q_Z I I a [4�00W.Cypress St.Ste.200,Tampa,FL 3 Owner Phone Number Ownees Address Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS [--nOlS Moulden Hollow Drive LOT# SUBDIVISION F,+Idden River Phase One B PARCEL ID#[2 _�6 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRR ADDIALT SIGN DEM012i, INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION, BLOCK FRAME STEEL" DESCRIPTION OF WORK,. Single Family Residence Pool/Screen Enclosure Fence BUILDING SIZE [T�R SF 2376 SQ FOOTAGE HEIGHT I story BUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRCAL F"Xrl pROGREGGENERGY �—1 NiRE.C. ' AMP SERVICE r^7h | VPLUMB|NG. ! MGCMAN\CAL VALUATION OF MECHANICAL INSTALLATION =Q8S ROOFING �—1 SPECIALTY [--� OTHER --- . FINISHED FLOOR ELEV/Tm DYES p�OoDooNE�R�x U UYsG | �O ��� ��� BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ Nl FEE CURREN LIl�� Address 4600 FL 67 Linenao# ' ELECTRICIAN COMPANY =Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N _] psEounns^ ' Address 1034 Skipper Road, Tampa, FL 33613,,-- L�nnon# PLUMBER Z COMPANY [Bayonet Plumbing, Heating &AC,Tn77] SIGNATURE REGISTERED Y\,N_J pEeconnsx L-YINLj ' Address Lkcenoe# MECHAN|CAL /COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE ZJ REGISTERED Y/_N_J psEconesx L_I/NL_J Address % � OTHER COMPANY Eterling Quality Roofing, Inc SIGNATURE nea/msnEo LY/_N_ pssounmE^ Address 14211 Shoal Line Blvd, Spring Hill, FL 34607 Uuonoo# 1 CCC057991 ' xxxmxmnxVxUxNxnmnmoxonmxmnUUnmnnnoxxnxnnumnnooxnmoxuxmxxvovnnxxmnwv RESIDENTIAL Attaoh(2)Plot P la set of Energy Forms;R-OAW Permit for new construction, Minimum ten(1V)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&.1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1C)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance / SIGN PERMIT Attach(2)gets nf Engineered Plans. /| °^**pROPERTY SURVEY required for all NEW construction. �| . [ Fill out application completely. Owner&Contractor sign back of application,notarized If over$260V,allotice of Commencement is required. (AICuporades over$7500) °^ Agent(for the contractor)or Power of Attorney(for the owner)would bo someone wit�notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy ofcontract required) Ramofsifshingles Sewers Service Upgrades A/C Fonuaa(P|oV8ummy/Fnoaago) Driveways-Not over Counter ifon public modwoyo..naudoROW .'D RESTRICTIONS: The undersigned understands that this permit may be subject to;deed" restrictions" More restrictive than County regulations. The undersigned assumes responsibility for compliance with any NO'Ci restrictions. wV1 CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or a undertake work, they may be required to be licensed in accordance with state and local regulations. If the not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the /ork, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- jrthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign ,of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the or, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco PORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands ransportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of n existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 7, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of mitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to ceiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or al power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact ees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: -- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is. to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a.separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICES COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT _ CONTRACTOR Subscribed and sworn to(or affirmed)before this Subscribed and s r o(or affirmed)before me this uo-pan-i y by Ashlee Callahan 08Jan-19 Ashlee Callahan Who islare personally known to me orhasihaae predused- Who is/are pe sonally known to me or has/have pfedue- as identification. as identification. Notary Public Notary Public Commission No. FF98537 ommission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped tl� 1d.�I�JI$ N P1� 11�.EK�il1J�ill�hl E4.", y� e�m� entM��a�All? ijC�rrnl�.�pp6�6@� iF p41~,ial�urrr�'��� i6,pMa�Jtinva'�4�d � �I - ��'�JT,rr�Filalwot�i1G341Y9,�R11- fl�ndMl�ha'r�ryealu�a�.�q�lDt.ai�Jpll - . --=_ FORM R465-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B1 sf ADS Carrier VW Builder Name: Lennar Homes 0095 Street: 3306 Moulden Hollow Drive Permit office: Citv of Zephyrhills City,State,Zip: FL, Permit Number: 15,z- Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2, 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Duct c. R= ft2 s R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.33 101.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.246 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 ' a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 58.79 PASS Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans and 'Ck sxq this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �Q(/e Wl/JAG/w with the Florida Energy Code. '' PREPARED BY: Yl Before construction is completed " . DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this building,as designed, is in compliance Florida Statutes. = with the Florida Energy Code. OWNER/AGENT: BUILDING OFFI�j DATE: DATE: I� L -�`l f - Compliance uires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified fac ory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 1/15/2019 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B1 sf ADS Carrier VW Builder Name: Lennar Homes 0095 Street: 3306 Moulden Hollow Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Duct c. R= ft2 s R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.33 101.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.246 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 58.79 PASS Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans and T -- this calculation are in compliance with the Florida Energy specifications covered b this P 9Y P Y Code. calculation indicates compliance Dave A/w/ C/w with the Florida Energy Code. F+:' itrir `"= ';;?• '�ti 0. tiWl YC PREPARED BY: Before construction is completed , DATE: this building will be inspected for compliance with Section 553.908 ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. Orj i OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as j certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 1/15/2019 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B1 sf ADS Carrier VW Builder Name: Lennar Homes 0095 Street: 3306 Moulden Hollow Drive Permit Office: City of ZephyrhiIls City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 11.Duct 0 c. R= ft2 s R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.33 101.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.246 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 58.79 PASS Glass/Floor Area: 0.081 Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans and 0 :'CXfST.gr this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance /, with the Florida Energy Code. PREPARED BY: Dave AupicGt Before construction is completed 'w DATE: this building will be inspected for 1, - compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. , with the Florida Energy Code. CQDiS' ' OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/15/2019 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM,R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1941 B1 sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Vinyl windows CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated; 1 master 210 1680 No 2 1 1 Yes Yes Yes i 2 family rm 341 3171.3 No 0 1 Yes Yes Yes 3 cafe 161 1288 No 0 1 Yes Yes Yes 4 kit 182 1692.6 Yes 0 1 Yes Yes Yes 5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes 6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes 7 bath2 61 488 No 0 1 Yes Yes Yes 8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes 9 o wic 104 832 No 0 1 Yes Yes Yes 10 privy 24 192 No 0 1 Yes Yes Yes 11 o bath 117 936 No 0 1 Yes Yes Yes 12 laundry rm 100 800 No 0 1 Yes Yes Yes 13 foyer 148 1376.4 No 0 1 Yes Yes Yes 14 hall 43 344 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 ___ 0 0 1 2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 ___ 0 0 1 3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 0 0 1 4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft2 e_ 1 0 0 1/1 5/201 9 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 e__ _ 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 ____ 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 -__ 1 0 0 8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 -__ 0 0 1 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 -__ 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 ___ 1 0 0 11Slab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0 12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I 1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood 3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood 6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood 7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood 8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood i 9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood 11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood 12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood i 13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood 14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood i 1/15/2019 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width , Height Sheathing Framing Solar Belo w R-Mahle Et In Ft In Area RA/Alle Fraction Ah�,or Grade% 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 13 N=>NE Garage Frame-Wood o wic 11 12 0 8 0 96.0 ft2 0 0.23 0.01 0 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 16 N=>NE Garage Frame-Wood laundry rm 11 7 5 8 0 59.3 ft2 0 0.23 0.01 0 _17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 _18 W=>NW Garage Frame-Wood foyer 11 16 4 9 4 152.4 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 i WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None 2 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 5 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in None None 4 E=>SE 7 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 5 E=>SE 8 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 6 N=>NE 10 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation j 1 416ft2 416ft2 43.7ft 8ft 1 1/15/2019 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6 FORM,R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000376 1908.7 104.79 197.06 .2844 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency ' Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1050 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm --cfm 58.1 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma ri Jun X Jul X Au X Se Oct Nov Dec Heatin f X Jan Feb f Xj Mar f Apr f May Jun Jul 4 Au4 Sep E Oct H Nov X Dec Ventin [ Jan Feb X Mar [X A r [ Ma Jun Jul [ Aug [ Se [X Oct Nov [ Dec I f I I' i iI I 1/15/2019 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(1ND) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM - 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 -68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 1st Floor Default 8 Ibs/s .ft. 0 ftz Oft 0.3 2nd Floor Name: Signature: Rating Compant: Date: . I i i I 1/15/2019 9:48 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/family rm 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1936 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.383 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.246 14. Heating system: Capacity 34.6 c)Area 7c. 157.3 a)Split system heat pump HSPF 8.5 b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 15.Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11c. d)Multizone cooling credit d) Radiant barrier installed 11 d. No e)Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signatureeome: Date: 01/15/19 Address of Ne 3306 Moulden Hollow Drive City/FL Zip: . FL Zephyrhills, FL 33540 1/15/2019 9:49:06 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Anal Job: 1941B1sf ADS carrier VW g YSIS Date: 1/15/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design C• • s Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 5.2 8173 29.7 Ducts Glazing 20.7 3472 12.6 Wall Doors 23.5 466 1.7 Infiltration Ceilings 1.3 2429 8.8 Floors 3.5 6726 24.4 Infiltration 1.7 3056 11.1 Ducts 3221 11.7 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 D�Ceilings Adjustments 0 Total 27543 100.0 Me IT • Component Btuh/ft2 Btuh % of load Walls 2.8 4336 16.5 Wall Glazing 47.2 7907 30.1 Internal Gains Doors 18.4 365 1.4 Ceilings 1.7 3358 12.8 Floors 0 0 0 Infiltration 0.4 684 2.6 Ducts 3628 13.8 Ventilation 0 0 Ducts Internal gains 6030 22.9 Glazing Blower 0 0 Infiltration Adjustments 0 Total 26308 100.0 other Ceilings Latent Cooling Load=4280 Btuh Overall U-value= 0.097 Btuh/ft2-°F i Data entries checked. -Fk =ightsoft- 2019-Jan-15 09:45:24 ^�^•� ww--w••pw Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..ipment%1941 sf ADS template VW 3ton Carrier.rup Calc=MJ8 Front Door faces: W Project Summary Job: 1941B1sf ADS Carrier VW 1 ry Date: 1/15/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Proiect Information For: Lennar Homes Notes: vinyl windows I Desicin Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24322 Btuh Structure 22679 Btuh Ducts 3221 Btuh Ducts 3628 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27543 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26308 Btuh Method Simplified p Latent Cooling Equipment Load Sizing, Construction quality Semi-tight Fireplaces 0 Structure 3619 Btuh Ducts 660 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ftz) 1936 19A Equipment latent load 4280 Btuh Volume(ft3) 16360 16360 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30587 Btuh Equiv.AVF (cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade PERFORMANCE 15 HP Trade PERFORMANCE 15 HP Model 25HBC537AO030 Cond 25HBC537AO030 AHRI ref 10487322 Coil FX4DNF037L AHRI ref 10487322 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 29750 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5250 Btuh Temperature rise 26 OF Total cooling 35000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 .in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point= 27 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -4- wrightsoft- 2019-Jan-15 09:45:24 �� •a.. w^•� M Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..ipmenW941 sf ADS template VW Stan Carrier.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: 1941B1sf ADS Carrier VW Date: 1/15/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26308 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 4280 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 30587 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29750 Btuh 113% of load Latent capacity: 5250 Btuh 123% of load Total capacity: 35000 Btuh 114% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 27543 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26710 Btuh 97% of load Capacity balance: 27 OF Supplemental heat required: 833 Btuh Economic balance: -99 OF Backup equipment type: Elec strip �. Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. 1 wright3Oft® 2019-Jan-15 09:45:24 arR:N��owe � m Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCk ..ipment11941 sf ADS template VW 3ton Carrier.rup Cale=MJ8 Front Door faces: W Jacqueline Boges From: Jordon Davis (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com> Sent: Wednesday, February 6, 2019 4:03 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3306 Moulden Hollow dr by#20752 ##- Please type your reply above this line -## Your request (#262050) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/262050 ....................................................................................................................................................................................................................................................................................................................................................................................... 'ff Jordon Davis (City of Zephyrhills Support ) Feb 6, 2:02 PM MST WO#765426 created to install new meter to the property. Best Regards, Jordon I FATHOM Support ............................................................................................................................................................................................................................................................................................................................................................................ Jordon Davis (City of Zephyrhills Support ) Feb 5, 4:01 PM MST Account has been added and services are being mapped. Account number 0000889145- 003124204 Best Regards, Jordon I FATHOM Support ..................................................................................................................................................................................................................................................................................................................................................................................... ,> Jacqueline Boges i �- -- Feb 5, 2:1 8 PM MST I service oulden hollo dr`�bp 2-0T752 I This email is a service from City of Zephyrhills Support . 1 ' Lennar Homes-3306 Moulden hollow dr-2,376 sq ft s Column SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - -� I VALUATION $ 267,656.40 I FEE SHEET $ 1,380.00 ADDRESS $ 30.00 DRIVEWAY1 $ 45.00 BUILDING: $ 1,482.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,145.00 TOTAL $ 2,145.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES i. POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 i SUB-TOTAL $ 6,272.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,478.97 PASCO COUNTY, FLORIDA Permit No. ZO 7 vr'Z Date Permitted —3o-49 Builder Name/Owner Name o,in h 40o-,'e_ Control#' County Papoel No. 2�{�2�0- Z/-OIUt�p^DOL��-a4So SubDiv: PK Address/Location c33 0(o Wl.�GL� en Uh((&,R) le- Classificatlon/Type of Use &i 14 Lryv'& 2/ 37G TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2t;W Exempt ❑Yes [] No How Determined Impact Fee Amount $ . 3r Zone No. TAZ: SCHOOL IMPACT FEED S� Account (056) Single-Family Detached House Amount $ 7_ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes ❑No How Determined PARKS AND'RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total i Zone TOTAL AMOUNT $ 7(4p Exempt ❑Yes ❑ No How Determined j. LIBRARY FEE _ — Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By d Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY I Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes 3306 Moulden Hollow Dr.2,376 Sqft Column SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 I FEE SHEET $ 1,380.00 i ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,487.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,150.00 Public Fee 10 TOTAL $ 2,150.00 I SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,277.13 I PARK IMPACT FEES $ 769.56 I' I SIF'S: $ 7,628.00 100.0% $ 7,628.00 1.0% $ 76.28 TOTAL: $ 7,704.28 T I F'S : $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,382.97 PASCO COUNTY �,j f�/C/�Q D0�j so PAO IA I) BUILDING CONSTRUCTION SERVICES 8731 Citizens Drive Date:4/30/2019 COUNTY FLORID�A Suite 230 OPEN SPACES.I aura,r PIACOS. New Port Richey; FL 34654 727-847-8126 NOT PERMIT '�� Receipt#: 1852389 FEE DESCRIPTION ACCOUNT CODE LIN-ITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.0.0 1453390 $45.00 $45.00 1852389 4/30/19 Waste Single Family TOTALS: .$45.00 $45.06 Receipt# Paid.Bv. Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1852389 Check 01212933 MLARNOLD BCCCP59W 04/30/2019 $45.00 Total Payments: $46.06 Pavor Address Phone Lennar Homes, LLC Comments: � 3306 Moulden Hollow DR While you will be paying your bill with Pasco County.Building Constructlon Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. I i I I MyReports/reports//PASCOPROD/PASCO/ReceiptAA V7.rpt 4/30/2019 Page 1 of 1 K41 -I Wa t. .._.......... '+._ ...................... I co I t 1 tit c'' ~sue; = I' "€• ' ! IL • ,U19 MESTER13ROOKE LANE jp- DIN co to -__ nf_e.,.,,�..°•,9wM1Y �i __-FM Y.I� �+T�.���•_ _ +_�i5 Ie+ „�a�a.aaaav�+�+� • 6� lit ICa Pi I I Dob , ".30.n111P r LYHOONN:HALL DRIVE,... P SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 9 5 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT 1� MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = s607.20_SQ- FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =_15_56 _SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY =_ 40 _SQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND GARAGE = 407 _SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI = N/A SQ. FT. SHOWN_ PROPOSED DRAINAGE FLOW PATIO =�23 SQ. FT. = DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE CONC. DRIVE = 475 __SQ. FT. NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE A/C & CONC PAD =--9 SQ. FT. PRIVATE SIDEWALK =__29__SQ. FT. In DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: IMPERVIOUS = 38 q PAGE INDICATES THAT PLAT IS IN 2539 SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = A _ SOD =�4068 S0. FT. CHANGE PROPOSED PAD ELEVATION = AND/OR REVISION. FRONT SETBACK =1' _OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK = 1 RIGHT OF WAY = 720.07 SQ, FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 0' DRIVE APRON =_144 _SQ. FT, PUBLIC SIDEWALK =_240 SQ, FT. STRUCTURE TIES SHOWN HEREON DENOTES SOD =_336 _SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. TOTALS * = 10' DRAINAGE/UTILITY EASEMENT AREA =_7327.27 SQ. FT. '• = 5' DRAINAGE/UTILITY EASEMENT DRIVEWAY = 619 —SQ. FT. SIDEWALK = 269 _—SQ. FT. SOD = 4404 SQ. FT. PLAT / / BOUNDARY 25.00' LOT 94 Ljj > r' o I LOT 131 S 89'40'43" E 110.00' ,�3 s Oho •: 7?I ESQ-F �o —�� 3 O ... O 50' __ :: - S 89'36'S8"'E � V..2.4..5Q 65,-0 Oa ..0.' ...I.... 0 rp N w>^ 20I50' , ... O 3 0_Y W .. ...t........ + w �w z z :m¢=c� m om o a I LOT 130 W ' aofzp5 0d-''J of O 0o * N a- W I O O _ I O Z .........29.67�.......... .......24:50�... ** - - - - -o- - - L 2 . o' r�J ^'• r—'�" N 89'36'58" W 110.00' A — S2j l " , —PRM(P) PLAT (NP) BOUNDARY �I PLAT BOUNDARY' LOT 96 LOT 129 HIDDEN RIVER PHASE ONE A en (PLAT BOOK 74, PAGES 101-121) v m u7 I� 00 O PROPOSED: LOWEST FLOOR ELEVATIONS: 3 LIVING AREA: 74.10' DESCRIPTION: E EVAT ONSER•EFERENCED TO m LOT 95, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA w OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. a a APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 12101 C 0458 F EFFECTIVE DATE: 9�26�2014 Project Number: Square Feet: 6607.20 t LENNAR HOMES Z LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= o CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, 2 F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED m PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT,CONTRGL POINT, PRM= PERMANENT a, REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBI�I TEMPORARY BENCHMARK, o U P= UTILITY POLE W F= WOOD FENCECL _ -- JOHN R.BEACH&ASSOCIATES,INC. Drawn 5M5 By. ` SURVEYORS AND MAPPERS Checked B z 911 WEST ST. PETERSBURG DRIVE Y: v ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 11/9/18 ACS 3 THE ORIGINAL RAISED SEAL OF A FLORIDA GN URE DATE LICENSED SURVEYOR AND MAPPER JOHN BEACH n Revisions: FLORIDA G. LAND SURVEYOR No. 2984 LB 4493 JEFF M. HA TLEY i LL AL SURVEYOR & MAPPER No.7123