Loading...
HomeMy WebLinkAbout19-20789 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20789 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20789 Issued: 2/08/2019 Address: 6865 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 365,185.45 Total Fees: 15,565.19 Subdivision: SILVERADO Amount Paid: 15,565.19 Date Paid: 2/08/2019 Parcel Number: 05-26-21-0100-01200-0090 CONTRACTOR INFORMATION. OWNER INFORMATION " Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DRIVE TAMPA, FL. 33637 TAMPA FL 33637 Phone: Lic: Phone: 813-574-1968 Work Desc: CONSTRUCT SINGLE FAMILY 3,153 SQ FT APPLICATION FEES BUILDING FEE 1,931.40 ELECTRICAL FEE 409.50 PLUMBING FEE 273.00 MECHANICAL FEE 191.10 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 PARK FEES SF 769.56 / I Ins ections,Re uired FOOTER 2 D ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Rennspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. (F) &__ 6"4997 CONrRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD'FROM WEATHER INSTR#2019021547 OR BK 9855 PG 3791 Page 1 of 1 Paula,S. O' eta Ph..D, Pasco County Clerk&ComptrotTerr4 Permit No. ��� . Parcel ID No 05-^crirJ NOTICE OF COMMENCEMENT :'State pf FiOrida County of Pasco L Y:TH2 UNDERSIGNED be-by gives notice that improvement.will be made to certain real property.,and in accordance with Chapter 713.-Florida Statutes,- !ne-foI[owing imforrnailon is provided in this Notlee of Commencement: /�� Des Aption of Property.'Parci:l Ide�n�tifiication No. 1.cAn c9 -GDCAf—_ 1c�. '•�i+'VC�7t[�J �b ��I1d S2 Street Address: W t'a c.c t .f�h,t kit i EL T3 354{ 2. GendralDescriptionofImprovement'New$in(3ie Family•Rgsiden-Ce 3. Owner information or Lessee information if the Lessee contracted for the Improvement: EI R• H-ortOn fnc ' Name 12609 Ttslenom Oilue Tamna .336,` Z _ _EI 'Address' ' City 'State interest in Property: -.ae sim.ple Name of Fee Simple.Titlehoida r (If different from Owner listed above) Address City State , 4.. Coniractor. Q.R. Hbrton, InQ 12602 Telecom Drina Tim .. 3362 FL` Address City State - Contractors Telephone No.: 5. Surety: .NtA Name Address City State Amount of Bond: y NIA' Telephone No.: s. Lender: NIA Name. Address City State Lendees Telephone No.: Persons within the State of Florida designated by,the owner upon whom,notices or other documents may be served as provided by, Section 713:13(1)(a)(7),Florida-Statutes: David G• de -----= lei City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: ff6 S v1040�i tX0OF Permit Type: l2 3 S aj S �- Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be-kept with the permit and/or plans. FEB Kalvin it Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) Single Family Dwelling Plan Review Comments 1: F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall.. graded to comply with R401.3 of the F.B.C. 3. Compaction test required.if 24" or more of fill dirt.is brought in at any one place. 4. Tie in survey required before-pouring concrete. 5. Driveways require a R.O.W. use-permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met.: . 7. All property markers sha1.1 be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages :shall comply with section R302.6 of the F.B.C.-(Fire Separation). . 11. Appliances shall not be installed in a location where subject to mechanical damage unles's. protected by approved barriers. M303.4:of the F.B.0 12. Water.heaters shall comply with section P607.3 of the,F.B.C. 13. Foundation supports for A/C units-shall be raised at least 3" above finished grade. M13:08.1. 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be 'installed in accordance with R313.1 of the F.B.C. 16. All glazing :requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to.be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in' showers or tubs. R702.4:2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms:will be required in new construction that uses fossil.=burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to:unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24: In accordance with the Land Development Code, lots shall_ be sodded before final at least 10 feet around the structure: 25. Blower door test and blown iri insulation card shall be provided before C:O. 26. A copy of the enemy eacls shall be with permit at all-times 27.. Cony of final ths'Oad6 report shall be.-provided with:permit before.rinal 28.No fence:.pool or screen enclosure is.issued with this permix ERE.-Finished Floor Elevation F.B.C­Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) City of Zephyrhills Permit Application Fax-813-780-0021 f Building Department Date Received lw 10 l`-a �,t-•' G Phone Contact for permitting -r�r-r'r-r-rr-r p Owner's Name i a r-. Owner Phone Number =_ 5 iL fI Owner's Address +nioST 1 c`` ' �'' t C!b�j�c�� _'5vow*ner Phone Number �^ Fee Simple Titleholder.Name r Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 1p J l Qii LOT# Z SUBDIVISION PARCEL iD# � ,�7 G'`�a ' Q" 1 �' Oil (OBTAINED FROM PROPERTY TAX NOTICE) ; WORK PROPOSED NEW CONSTR R ADD/ALT � SIGN � [� DEMOLISH -INSTALL REPAIR PROPOSED USE ®— SFR COMM OTHER TYPE OF CONSTRUCTION • �� 13LOCK FRAME STEEL 0 DESCRIPTION OF WORK Or1G't-Y� J`�/Yf 1�" �c^Y�� ! t{ �' d� e_^ ,C BUILDING SIZE SQ FOOTAGE too 3i6 HEIGHT RTI I I •I T ItTT 1'T'rr'9"Ir rYi'1"T T I�1Ti"r't�l"t"r`r�l'•tr'�'7'T d T" =BUILDING $ l DT f VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $. AMP SERVICE PROGRESS ENERGY W.R.E,C. =PLUMBING MECHANICAL $ r o VALUATION OF MECHANICAL INSTALLATION =GAS 0 ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS i 3 ` FLOOD ZONE AREA DYES NO -6-1-F-1--1- •-i--i-a-4-4-a-C-•F-G-F-a-✓E-1 i-1-i•-F-:•-GAF- --1-F-F-i-C-:a,1-i-I�C-;r-i-i-1-,t-1-1-0-1�v-1-4-:-1-0-�-1--lei-y-°r•i-i-Q-i-t'-f-1- BUILDER �� COMPANY - �`�c) a),c SIGNATURE REGISTERED LY j N J FEE CURREN Y I N Address /crrl �� j� <e .r"h i— License# &BygL s—7,o 6 ELECTRiCiAN � c•. ,� COMPANY c SIGNATURE.. REGISTERED Y/ N FEE CURREN Y/N Address License# 8 4 r � PLUMBER COMPANY SIGNATURE /�,r� "� �.�.� REGISTERED Y/ N FEE CURREN Y/N,/ I Address [ �"'��� License# a tot MECHANICAL COMPANY p"�;Ii� .f,, �dY,� SIGNATURE "s�,^r "" '"'-REGISTERED Y// N FEE CURREN Y/N Address ` x9a.,11_11.0, e5V License# t t OTHER COMPANY ( �^` SIGNATURE REGISTERED Y/ N Y/N Address .�f !�'F s° A E � �� License# i11ii11iTlliliillillllllllllllllilllliilllillllillllil• 0111i18l1l11 RESIDENTIAL. Attach(2)Plot Plan+_; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required on site,Construction Plans,Stormwater Plans w/Silt.Fence installed, Sanitary Facilities 14 1 dumpster;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach (2)completa: }efs of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10)%.,)rking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities 1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Plans. "PROPERTY'SURVEY required for all NEW construction. •i-1-1-.f-i.-1-l-1-l.-l-4-l-i-i.�f-i.:#..;:- ?l,-l-G--l-.i-E-I-l--l..l->R-i-l-l..l-b-i-.l-•i-F-0-a-l-i-l-d-b-�I.-l-l•-3-.i--i.�..i-! 7irections: Fill out application completely. Owner�Contractor sign back of i)piication,notarized If over$2500,a Notice of Comnwricemertt is required. (A/C upgrades over$7500) Agent(for the contractor)or Pownr of Attorney(for the owner)would be someone with notarized letter from owner authorizing same JVER THE COUNTER PERMITTING (copy of contract required) :Ieroofs•if shingles Sewers `3ervice Upgrades A/C Fences (Plot/Survey/Footage) Driveways-Not Over Counter if on public roadways..heeds F40W ' . . NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions", which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors tounde�okevvork. they may benoqu�mdiubo licensed in accordance with nte1e and-local regulations. |�the contractor is not-licensed on required by |aw, both the owner and contractor may be cited for a misdemeanor violation under state law, If the owner or intended-contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Lice'hsing Section at 727-847- ' 8009. FurthBrmore, if the owner has hired 8 contractor or oontraotors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign a th� contractor, that may bean indication that he is not properly {ivanoad and is not entitled to permitting phvi|egeain Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation |mpe:ct Fees and Recourse Recovery Fees may apply tothe construction of new buUdinQa, change of use in existing buildings, or expansion of existing buildings, am specified in Pasco County Ordinance number 8Q'O7and 9U'07. as amended. The undersigned also understands, that such feas, as may be due, will be identified at the time of permitting. it is further understood that Transportation Impact Fees and Resource Recovery Fees nnuaT be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power ra|e8sa, the fees must be paid prior to permit issuance. Furthermore, if Pasco-County Water/Sewer Impact fees are due,they must be paid prior to permit issuance |O accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, asommonded): |f valuation of Work ie$2.SOO.0Uormore, | certify that l, the app||oent, have been provided with a copy of the "Florida Construction- Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAgdoiu|tUr9.and Consumer Affairs. If the applicant is someone ` other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver|tto the''owner" prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |avvn regulating construction, zoning and land development. Application is hereby made to obtain a permit to do,work and installation as indicated. | uarUfv that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating nonatnuCdOO' County and City codes; zoning regulations, and land development regulations. in the jurisdiction. | also certify that I understand that the regulations of'othe'r government agencies may apply to the intended work, and that it is my responsibility to identify what actions [ must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental P,otect|op'Cypraon Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress. Bayhaeda, Wetland Areas' Altering Watercourses. . ' Army Corps of Engineers-Seawalls, Oooho^ Navigable Waterways. ` - Department of Health 8 Rehabilitative Gan/icoo/Envinonrnonta} Health UnU-VVe\|n, Wastewater Treatment, Septic Tanks. ' US-Environmental Protection Agenov-Asbe8toeabatement. - Federal Aviation Authohty-Runvvays. | understand that the following restrictions apply to the use offill: - Use of fill ia not allowed in Flood Zone"V" unless expressly permitted. - If the fill me¢ariu| is to be used in Flood Zone "A', it is understood that a drainage plan addressing a ^compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State ofFlorida. - If the fill material is to be used in Flood Zone ^A. in connection with e permitted building using stem vva\\ construction, \ certify that fill\�U\ bo used only to fill the area within the stem wall. - If fill rna1eha| is to be used in any area, ! certify that use of such fill will not adversely affect adjacent . properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for |oLo |eoa than one (1) acre which are elevated-by fill, an engineered drainage plan is [equ|r'aU. |f | ann the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to oonnrnanuing construction., \ understand that a separate permit may be.required for electrical vvork, plumbing, aiQns, vva||s, poo|s, air condd1oninQ, gas,'or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed wbh-thexvorkand not as authority toviolate, canne|, aber, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors-in plans, construction or violations of any codes. Every permit issued shall become invalid un|aoo the work authorized by such permit is commenced within six months of permit issuaooe, or if work authorized by the permit issuspended or abandoned for a period,of six (6) months after the time the Work is commenced. An extension may be requeatad, in writing, from the Building Official for a period not to exceed ninety (AU) days' and will demonstrate � justifiable causefortheeXtenaion. If work ce ases WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FlNANCjNG, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA xu**/ (RyJ1/ou OWNER OR AGENT CONTRACTOR Subs r! e dsw to(or—affirm-ed)before me this Subscribed and sworn to(or affirmed)before me this . ... is /e personally known momm m � vn naso"�pou000 � o is/are personally known to me or xoemoxn identification. Identification. ' �_�\Notary Public Notary Public ` ~~ L-� -----^ ` Commission No. Commission ' Name onNotary typed,printed vrstampeu .jo,COUELINE MA Al001 commission 0 . es commission Expir 2022 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 9, BLOCK 12, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11 A & 11 B NOT YET RECORDED IN PLAT BOOK ----, PAGE(S) ----, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 8,106 SO. FT. LIVING AREA = 1.104 SO. FT. GARAGE = 437 SQ. FT. ENTRY = 111 SO. FT. LANAI m 0 SO. FT. PATIO = 80 SO. FT. Curve Table DRIVEWAY = 394 SQ. FT. A/C PAD = 12 SQ. FT. Cu^1e+ Length Radius I Delta I Chord Bearing I Chord WALKWAY = 29 SQ. FT. Cl 33.8Y 200.00' 9-41.51' S02-11.06-W 33.81' IMPERVIOUS = 27% = 2167 SO. FT. a SOD = 5,939 SO. FT. Una Table OFF LOT CALCULATIONS Una / Direction Length cpC RIGHT OF WAY = 793 SO. FT. z DRIVE APRON - 211 SO. FT. L1 S0239.49'E 16.55• 1" = 30' PUBLIC S/W = 254 SO. FT. L2 N3073'32•E 6.02' GR IC SC SOD = 328 SO. FT. II TOTALS 0 15 30 AREA = 8.899 SQ. FT. DRIVEWAY - 605 SO. FT. SIDEWALK = 283 SQ. FT. SOD = 6.267 SO. FT. � r PT . / I A LOT 10 BLOCK 12 I N �V _Y •y W �m 82 o? ___ S 57'5889 I w D&AE S8257'Sn 4D,7' 22.5' -_30.44•_ I FA V O'l 8 � ^�W N N _3a "� m op I nib ...:.:. ,�... _�z �' o o'a o'.Ti I I W 3 N82 toe.. ---_- •s.0•' 42.Br 4,•''m I I a W 6 / 57 58 0 (NON-RADIAL) t r 1 5' SON'°6S• � &AE ui 8.0'. 1 N� F- TRACT ' 1 L� •1 ci 2v 25.5:_ rRAC1 "Dn .O O� 1 7V.13. W ��I PRIVATE COMMON Q AREA 0+a L�' IL-1 j LOT 8 ��'' I Z a PREPARED FOR: BLOCK 12 �3 1 3 1 . ll•R•H1lE�I1lN �� BUILDING SETBACKS / FRONT: 22' REAR: 15' �� SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) SIDE STREET: 15' NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING PLANS PROVIDED BY THE CLIENT. LEGEND: 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. - —•—•— BUILDING SETBACK LINE PI POINT OF INTERSECTION 3. 3. FOR ALL LOTS WHERE SIDE SETBACKS PC POINT OF CURVATURE ARE LESS THAN 7.5', A MINIMUM 5' WIDE —-— CENTERUNE PT POINT OF TANGENCY DRAINAGE AND ACCESS EASEMENT WILL BE —- — RIGHT OF WAY LINE RP RADIUS POINT PRC POINT OF REVERSE CURVATURE LOCATED ON ALL SIDE LOT LINES PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ;,• CONCRETE (P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB CALCULATED PLAT BOOK . THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER POS PAGES OPT10N LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. FT, SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT WCASB WETLAND CONSERVATION F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. AREA SETBACK LINE F.I.R.M. FLOOD INSURANCE RATE MAP D&AE DRAINAGE&ACCESS EASEMENT NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT.A SURVEY- DN&UE DRNNAGE&UIWTCY EASEMENT THISTHIS IS A PLOT PLAN ONLY PUE PUBLIC UTTILITYAEAASEMENTENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SPTEMBER 26, 20 4. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE"X•, AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2X ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF.THE LAND. I GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING NO2s9'4,VW, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M E R 1 CA N ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: SURVEYOR AND MAPPER. 1• 30 FEET S U RV EY I N G �mmn wom�y� Digitally Mgned by J.—W SCALE: �`t"�" 8c MAPPING INC. ''' DN:cn=JamesWBoleman, APPROVED BY: `B f" - € =American Surveying&Mapping, ,cs,.0 �--•�— CERTIFICATION OF AUTHORIZATION NUMBER L8#6393 t ou,emali=)boleman@asmcarparate.co FOR 180620 LOT 9, 3191 MAGUIRE BOULEVARD, SUITE 200 s%';;••• m,c=us THE JOB NO. BLOCK 12 ORLANDO, FLORIDA 32803 Daee:aota.n.zt ta:as:as-os-oo- FIRM (407) 426-7979 DRAWN BY: DSB PLOT PLAN 11 20 2018 JL WWWAMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE D.R. Horton-6865 Wagon Trail St:3,153 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,820.00 ADDRESS $ 30.00 DRIVEWAYJ $ 40.00 BUILDING: $ 1,926.40 ELECTRICAL: $ 409.50 PLUMBING: $ 273.00 MECHANICAL: $ 191.10 SUB-TOTAL $ 2,800.00 Public Fee 1% TOTAL $ 2,800.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 " SUB-TOTAL $ 3,353.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,560.19 DR Horton Homes-6865 Wagon Trail St-3,153 sq ft lColumn Es SO. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,820.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,931.40 ELECTRICAL: $ 409.50 PLUMBING: $ 273.00 MECHANICAL: $ 191.10 SUB-TOTAL $ 2,805.00 TOTAL $ 2,805.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,358.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 , TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,565.19 PASCO COUNTY, FLORIDA Permit No. 2-0 7 6? Date Permitted r. Builder Name/Owner Name cb�- f16--6 L(,e— Control#' - County Parcel No. QS-n- -4 -0 1 ZQQ- 010 SubDiv: -4AD 100 Address/Location (ObGs wcoum Classification/Type of Use 1 it, 4M.- S, TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit Exempt []Yes No How Determined Impact Fee Amount 3t 32, Zone No. TAZ- SCHOOL IMPACT FEE Account (056) Single-Famlly Detached House Amount $ Z (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt �Yes n No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ 49 Sb Exempt n Yes F1 No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt C]Yes E] No How Determined Total Amounf=:: — RESOURCE FEE ERU TOTAL AMOUNT Prepared By k Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY ILA DR Horton Homes-6865 Wagon Trail St-3,153 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,820.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,931.40 ELECTRICAL: $ 409.50 PLUMBING: $ 273.00 MECHANICAL: $ 191.10 SUB-TOTAL $ 2,805.00 TOTAL $ 2,805.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,358.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,565.19 J Check Number 0873715 CITY OF ZEPHYRHILLS-PERMITTING Date 02/07/19 ' 5335 8TH STREET �, J DRH Inc: Controlled Disb Stub 1 of 1 2149668 PO Numb Invoice Number (Subdv Lot# Lot Address Cost Cde Legal Desc Gross Deductions Amount Paid -------- --------------- ------ ---- -------------_I—------------- -------- ---------- ------------- ------------- ------------- 391630085PERM 39163 0085 6865 WAGON TRAIL STREET 77/79 15,656.19 15,656.19 ----------- ----------- ----------- 15,656.19 15,656.19 / ti �•• YYYY . — Ya W a • —47— ••• 0210712019 2 PM Paula S. o1Nei p � G Ph..D, Pasco County CCerrk&ComptroGCer Permit-No. Parcel ID No 1)55 @b.ar..� "19too""•�/a.(�. d�V _ NOTICE OF COMMENC3EMENT= " State of:` Flodda County of Pasdo ..'THE UNDERSIGNED hereby gives notice-that improvement.will be made to certain real property,and in accordance with Chapter 713,•Fiorlda Statutes.- - the1otlowing Information is provided in this Notide of Commencement: p 1.`>. - . Description of Property: Parcel Identification No.r+p-r- G[.. i.� Se I Vt tdU 1—,h4se. • ." .. Street Address: EL ' 2. GendraiDescriptionofimprovement New Sinale Family'Residen.Ce 3. Owner Information or Lessee information if the Lessee contracted for the Improvement: Rbrt= Inc Name 1? C37 TaC .0 rive Tampa _ 336,37 El__: Address '. City 9 'State " Interest in Property: _Fee Simple Narne of Fie Slmpie.Titieholder. (if different from Owner listed above) Address City State , 4.. Contractor: D R Horton„ Inc Name" FL 12602 Telecom Drive Tampa 33637 Address city State . Contractor's Telephone No.: s: Surety: NIA Name . Address City State" Amount of Bond: N/A' Telephone No.: 8. Lender HIA Name, Address City State Lenders Telephone No.: FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev H Builder Name: DRH ExpresspHooMes Street: �(�Y� t 41 S} Permit Office: �` City,State,Zip: Zephyrhil s,FL, 335 LA I Permit Number: 7i0`7(�) Owner: 5- L V Jurisdiction: Design Location: FL,Tampa C, I I County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2389.10 ftz b.Frame-Wood,Adjacent R=11.0 314.89 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 5 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ftz 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11. Ducts R ftz 7. Windows(252.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 212.67 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.966 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features b.Raised Floor R=19.0 437.00 ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.097 Total Proposed Modified Loads: 85.18 PASS SS Total Baseline Loads: 86.22 /'�'��7�7 I hereby certify that the plans and specifications covered by Review of the plans and 0 tfiE ST.��� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance y. ip '� - ZZ �Y1♦ with the Florida Energy Code. F+ trn,, °•• ;;�";, .O PREPARED BY: Before construction is completed DATE: 11-24-11 this building will be inspected for compliance with Section 553.908 herebycertify that this building, as designed, is in compliance Florida Statutes. fY 9, 9 P with the Florida Ene`r�Code. OD WE'D OWNER/AGENT: `�-'c`^'`''- Q ` ^ BUILDING OFFICIAL: Y DATE: I a . 3 • 1 DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 On for whole house. 11/29/2018 10:26 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev H Builder Name: DRH Express Homes Street: eptC Permit Office: City,State,Zip: Z�hyr 111 Ls,FL, Permit Number: Owner: L-V Jurisdiction: Design Location: FL,Tampa I I - County: Pasco(Florida Climate Zone 2 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 scift.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2389.10 ft2 b.Frame-Wood,Adjacent R=1 1.0 314.89 ft2 3. Number of units,if multiple family I c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(252.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 212.67 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1,966 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 scift.) Insulation Area a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features EF:0.950 b.Raised Floor R=19.0 437.00 ft2 None c.NIA R= ft2 15.Credits Pstat Glass/Floor Area: 0.097 Total Proposed Modified Loads: 85.18 PASS Total Baseline Loads: 86.22 I hereby certify that the plans and specifications covered by Review of the plans and %EST. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: LA Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Enemy Code. Q OWNER/AGENT. BUILDING OFFICIAL: DATE:- 3 1 -'6 DATE: 2019 - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to 'outdoors, tested In accordance with ANSI/RESNETIICC 380,is not greater than 0.060 On for whole house. 11/29/2018 10:26 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 5 / . ' , 11/29/20 o1o:2sAN EnergyGauOo@ USA Section R4om�.1 Compliant Gn#vam Page cofs FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood WALLS - Adjacent y w Space Cavity Width Height Sheathing Framing Solar Belo# nrnt Tn Wall TVpp BA/Allip Pf In Pt In A r,-,q Mahe Erartinn Ah,;nr ('rqrfp% I N=>E Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0 2 W=>N Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0 3 S=>W Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft? 0 0.6 0 4 E=>S Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0 5 N=>E Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0 6 W=>N Garage Frame-Wood Main 11 16 0 8 8 138.7 ft2 0.23 0.01 0 7 N=>E Exterior Concrete Block-Int Insul2nd Floor 4.1 39 a 8 8 343.8 ft2 0 0.6 0 -8 W=>N Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 9 S=>W Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 10 E=>S Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated Main None .4 3 6 8 20 ft2 2 N=>E Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 90 degrees), Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>E 1 Vinyl 'Low-E Double Yes 0.34 0.31 N 31.0 ft2 6 ft 2 in oft 1 In None None 2 N=>E 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 6 ft 2 in Oft 1 in None None 3 S=>W 3 Vinyl Low-E Double Yes 0.34 0.31 N 46.5 ft2 1 ftOin 10ft10In None None 4 S=>W 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 5 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 2 ft 0 in 0 ft 5 in None None 6 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 N 8.7 ft2 1 ft 0 in 0 ft 10 in None None 7 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft? I ft 0 in 0 ft 10 in None None 8 S=>W 9 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 1 ft 0 in 0 ft 10 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0 11/29/2018 10:26 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 2640.2 144.94 272.59 .363 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 41 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts I Central Unit/ None SEER:14 40 kBtu/hr 1200 elm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap- Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 261 ft2 2nd Floor 45 ft2 Proposed Qn 2nd Floor ---cfm 156.3 cfm 0.06 0.60 1 1 TEMPERATURES Prograrnable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr Ma Jun 14 Jun J1 Jul Aug Sep Oct Nov Dec Heating Jan Feb Mar Apr M Jun Jul Aug Sep Oct Nov Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec - 11/29/2018 10:26 AM EnergyGauge@ USA Section R405A.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 Main Default 8 Ibs/s .ft. 0 ftz Oft 0.3 2nd Floor Name: Test Rater Signature: Rating Compant: Test Rater Date: 1 1/29/2018 1 0:26 AM EnergyGaugeOO USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/2nd Floor 3. No.of units(if multiple-family) 3. 1 4.Number of bedrooms 4. 5 13.Cooling system: Capacity 40.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 2605 d) Room unit/PTAC EER e)Other 14.0 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.373 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.315 14. Heating system: Capacity 41.0 c)Area 7c. 252.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8.Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f) Other 8.20 9. Floor type,insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 19.0 15.Water heating system c) Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10B2. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. Yes e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will-be installed(or exceeded) in this home before final inspection. Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: ��`^ -�� �`"- Date: I o�• �-I p Address of New Home: [0 �S ��1QGOV1�rLl�` S� City/FL Zip: Zephyrhills, FL 1 1/29/2018 1 0:26:27 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 ' ' ^ Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods Permit Number: F77 Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. / V SECTION R401 GENERAL �7 R4V1.o Energy Performance Level<sp4 display card VNonuaton0' The building official shall require that an energy performance level(EP4 display card be completed and'certified by the builder to be accurate and correct before final approval of the building for occupancy, Florida law (Section 553.9085,Florida Statutes)requires the EPL display card mbn included as on addendum to each sales contract for both preuo!dand nonpresoldmeidomVo|buUdingo The EpL display uarduontainainnonnabnnindioatingUho energy performance|ovo and efficiencies mr components installed ma dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted oodemonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. �] n4O2.4 Air leakage(MondmoqA. The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of GnmionaR^om4.1 thmugbR^Q2.4u. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C4ou.s. nouu.4.1 Building thermal onxe|npw building thermal envelope shall comply With Sections R4uu.4.1.1 and R4mz.4.1.2. -- The sealing methods between dissimilar materials shall allow for differential expansion and contraction. �7 R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed inaccordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code pffiuia|,an approved third party shall inspect all onmFmnomm and verify compliance. �l 8402.4.1.2Temting' The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones I and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANo|/RE8NB7|oC38O and reported ato pressure ofU.2 inch vxg.(5opaeodo).Testing shall bo conducted bYeither individuals as defined>n Section ns 8g8 (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(o)n,(1)or an approved third party.Awhtten report o,the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,a|tenatiuno,nnnovationo,or repairs,of the building thermal envelope mexisting buildings inwhich the new construction|oless than us percent m the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not seated,beyond the intended weatherstripping or other infiltration control measures. u including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures.. o.Interior doors,if installed at the time of the test,shall boopen. 4.Exterior doom for continuous ventilation systems and heat recovery venb|omm shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. a Supply and ngum regiomm.J installed at the time of the test,shall be fully open. R402.4'2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors factory-built fireplaces listed and labeled in accordance with uL 127.the doors shall ua tested and listed for the Omp|ono Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. �l R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cim per square foot 2),and swinging doors no more than 0.5 cfm per squarefoot(2.6 Unhn2),when tested according to NFRc4ouur AAMAI WDMA/CSA 101/I.S.21A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: aito'bum*indowm.skylights and doom. , 11/29/201810:26 AN snnrgyoauge0UnA FoC 6th Edition(2n14 Compliant Software Page 1pf5 ' MANDATORY REQUIREMENTS ~ /Co[tiOU8r8 ��2.4.4 Rooms containing fuel-burning appliances. |nClimate Zones nthrough 8,where open combustion air ducts provide combustion air to uopen combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope,Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. a. Fireplaces and stoves complying with Section R402.4.2 and Section R 1006 of the Florida Building Code,Residential. | |Fmou�.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than o.00fn(oo44 Us)when tested in accordance with AGTM E28oata1.57psf(7nPa)pressure differential.All recessed luminaires shall be sealed with a gasket ur caulk between the housing and the interior wall o,ceiling covering. SECTION R403 SYSTEMS F403.1 Controls. �] n4U3.1.1 Thermostat provision y0mnuatoqA. At least one thermostat shall be provided for each separate heating and cooling system. n403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. Fl 8o03.o.o Sealing(Moodomg) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(1),Florida Statutes,to be"substantially leak free"in accordance with Section n4oa.o.n. Fl n4ou.3.c.1 Sealed air hunmer. Air hand|emshall have amonufomum/edeoignadvnmran air leakage ofno more than upomont �� o[the design airflow rate when tested in accordance with ASHnAE1Vo. r-1 R403.3.3ouct testing(Mandatory). Ducts shall ba pressure reste m le akage � 1. Rough-in test:Total leakage measured with u pressure differential ufo.1 (nohw.g.(25P including the, manufacturer's air handier enclosure if installed sk the time of the test.All registers shall bo taped ur otherwise sealed during the test. o. Poomonohnuivntovt:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handier enclosure.Registers shall be taped or otherwise sealed during the teat. sucnpunnm: /. A duct air leakage test shall not uorequired where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 4osof this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ElR000.o.5 Building cavities(Mandatnq0. Building framing cavities shall not be used as ducts orplenums. 8«ou'4 Mechanical system piping insulation<MonuomqA. Mechanical system piping capable of carrying fluids above 1os"F(^1^[) o,below 5s^F(1n^o)shall bo insulated ma minimum of R-3. �� R4ox/�1Pmmmivonf piping insulation. Piping insulation vwpm�odm weather shall bepm�o�dhnm damage,inmudingthat �� caused by sunlight,moisture, | enimaintenonceand*ind.onduhaUpmvidovhidd|nghnmon)orradiationthatoanouuoa degradation of the material.Adhesive tape shall not bepermitted. �� n4no�./ *em�uwo� ci rculation Ho�odwa�,�mu|aUunsy�emonh�|buin �� accordance with Section n^ou.o.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R«O3o1.1Qouu|nmiun�mvsma Ho�odw�orcimu|�iunsystems shall bm provided with circulation Them return F7 pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. ' Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water m the circulation loop mat the desired temperature and when there iono demand for hot water. �� n4V3.s1.n Heat trace�summu. Ba�hohc�tmoeoyommoahoUcomply`�thIEEE 51n.1nrULo15.00ntm|am,such systems | �� shall automatically adjust the energy input ooVhohmatoauinVmmuinxainthedeviredwato,mmpommmiothepipingina000rdamm with the times when heated water is used in the occupancy. 11/29/201810:26xM snvrgyoauoe@)uoA reCath Edition(2n17)Compliant Software Page onf5 ^ , MANDATORY REQUUREMENTS ~ (Continued) [] with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank, n403.5. Water heater efficiencies(wanuato,y). �� n�n��.1.14u�m^�cvo�ro|� se�co��phe�nU�o�mmnmd|bao��od����m���mom�m mm| capable �� nh adjustment from the lowest m the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall bo from 1oo^Fto1^u~F(3n^Ctono^c). R403�.6'1.2 Shutdown' A separate switch mm clearly marked circuit breaker shall be provided m permit the power supplied uo electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types ox service water-heating systems vubv turned off. �l nou3.s.s.0 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. FJ 84ou.5'6.eu Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and o. oe installed atan orientation within 45 degrees oY true south. F] R000.n Mechanical ventilation yNandatuq0. The building shall bo provided with ventilation that 'meets the requirements ofthe Florida Building Code,Residential,nr Florida Building Code,Mechanical,as applicable,ur with other approved means ofventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system iv not operating. �l Rouu.s.|Whole-house mechanical ventilation system fan efficacy. When installed m function oso whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered byun electronically commutated motor. R400.6.o Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: I. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall bo the maximum rates allowed for residential applications. o. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-1 I and the ceiling shall be insulated to a minimum of R-1 9,space permitting,or R-1 0 otherwise. R4o3.7 Heating and cooling equipment(Mnnuom0). B4m3.c1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based onthe equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section RoVo.1.This Code does not allow designer safety factors,provisions for future expansion o,other factors that affect equipment aizing.System sizingoa|cu|atiunoahaUnotinu|udo|oadsvmatndby|oua|intonnioontmoohonioa|vonU|o1ionvuch as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipmentohal!hmmaoeffimen rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. T&BLER403'6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACy a AIRFLOW RATE MAXIMUIV Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 90 2.8 cfm/watt Any For a|:1 cfn~uo.3Umin. u. When tested in accordance with HV|Standard o10 iViANDATORY REQUIREMENTS - (Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: i. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florlda-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.80C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 11/29/2018 10:26 AM EnergyGaugeOO USA -FBC 6th Edition(2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(MandatorSohe energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 11/29/2018 10:26 AM EnergyGauge@ USA FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605 Elev H Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Jurisdiction: uJ r Design Location: FL,Tampa COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa c 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and Wring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and w t ring. Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between ire * J I "Pb" a.In addition,inspection of log walls shall e,4nWgftffthfhae"Si��gg���oitICC-400. 11/29/2018 10:26 AM EnergyGauge@ USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: 'JAI pn Builder: DRH Express Homes Community: Lot: 9/12 Address: City: Zephyrhills State: FL Zip: Alt c9ire4critIvo, -Qd p- i)+T hit:§h�il-i,tbe'..'teEitdd,i�dd.vedfied ia-s''h irl 6r9kage,rat (b)�0.ebdI'q9.7 air X00. — .— d psiodrihout zit-aipr.ossure df'O..2,;Iflch,,w.g.!,(Sb A -'N%'dr,440 -0'unii!gtiEill'be tdgted-dr-t'd-,,Vbrified-as havingof rf t' x, I- -rate d 6 be6d n -,theseiected,AdH valpej 'W"' 'Form F1405�'apl,7"(,P.�bfforMkfi�cE,A-5 p own,,qn, ,JR4 64 0417 x 60 — 22630 Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans FPASS I*Code software calculated When ACH(50)is less than 3,Mechanical Ventilation installation 0 Field measured and calculated L must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(D,(g),or(1)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Tes ting pmpqny, Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 11/29/2018 10:26.43 AM EnergyGauge(D USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 Of 1 Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 .Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: _4,!Ihfbrrn.6fion Builder: DRH Express Homes Community: Lot: 9/12 Address: City: Zephyrhills State: FL Zip: ive Othod h 0 �O :P-,-r,'fdrffi AnCe/ER1;Method System I cfm25 'd WthOd Offi'28 9 I(T-Ot-0) 'T I .System 2 cfm25 t o(qgaiify,,As"'subgtanti'Allyilijft free":Qn T fi_k. �,,Otal rn"u� :be 1ha, bf System 3 cfm25 iih§t8[IIdd,:Qn'TOtaI'rnustIbe less:than oriel udl to'0.'03.'This testing eot4,.thq:rb,-Qj-jirdmt en s.in,4060r4ance,whi -'% h, R itOtio403:8 3..Sum of any cfm25 #s1thea ,hohdl6r?ohit-ihstal[6d,OVrih Y Total of all cfm25 P-0 Of 0 f,f 111 h b- 8 KI M t ;dfh-25'(Q'Ut qr Tot al) 0 -u Uisihgjt' -..Ot 10q,,Qmffiu tn'Ot lbe;gfroater1h,a h---the rify hit!M h A - A I&A Form iF `7 2605 Qn ;pff,,000$, 0',d-01, -41<490"96 O%ifiOd on Fbt -14'05=201� r Total of all Total Conditioned systems Square Footage !U?Akag6 Ty Q4?! P619616t-:M-Mb h-FOrtn-, Qnd�g--p—qp-ffiie d�o--n- Form ;-.406-2OT 7 PASS FAI L Proposed Qn 0.06 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/iCO380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i), Florida Statutes. 'Te;;sting;Company Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above,either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification Issuing Authority: 11/29/2018 10:26.49 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Manual S Compliance Report Job: wrightsoft® Date: Entire House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Cl,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 license:CAG033669 Project Information For.- DR Horton Lot 9 Blk 12 Silverado, Zephyrhills, FL Cooling- Equipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 32540 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 36683 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmerittype: SplitASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 100%of load Latent capacity: 6269 Btuh 151%of load Total capacity: 387*14 Btuh 106%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 40.0°F Heat loss: 28704 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmerittype: SpIjtASHP Manufacturer: Carrier Model: CHI 4NBO42'**A+FB4CN P042 Actual airflow: 1367 cfm Output capacity: 37299 Btuh 130%of load Capacity balance: 33 IF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 102%of load Temp. rise: 18 OF Meets are all requirements of ACCA Manual S. 2018-Nov-29 10:27:09 +wrightSoft' Right-SulteO Universal 201717.0.21 RSU25554 Page I ...press hornes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: E ^ � «�����0 Job: —~-- -----' - - —'-- Date: . � Entire House By: �un' Mmvuon�aus Progressive Air Systems, Inc ' a90r Dasher o'.Pod Richey,FLy*mm Phone:re7-o47-3nuuFax:727-815-3399 ucnn,o:cx0000aoy Project Information For: DR Horton Lot 8B|k 12 Si|vorado.ZephyrhiUx. FL Design Information Htg Ci0 Infiltration Outoidodb 40 01 Method Simplified Inside db(O 70 75 Construction quality Semi-tight Design TD (OF) OU 18 Fireplaces U Daily range ' L Inside 50 50 Moisture difference(Or/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carder Trade CARRIER Trade CARRIER Model OH14NB042*°**A Cond CH14NBO42*°°°A /\HD| rof Coil FB4CNP842 AHR| ref Efficiency 8HSPF Efficiency 11.3EER. 13.7SEER Heating input Sensible cooling 30750 8tuh Heating 38500 BtuhCD47"F Latent cooling 10250 Ehuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 ufm ' Actual air flow 1367 cfm Air flow factor 0.048 ofn/Btuh Air flow factor 0.042 otn/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=93"F Backup: ROOM NAME Area Htg load Clg load Htg AVF Clg AVF bed 154 2906 2160 138 91 ' powder 59 950 304 45 15 flex 156 3048 2720 145 114 foyer 75 1416 840 07 35 stairs 44 U O U D bed4 181 1973 2381 94 99 bud3 184 2272 2862 iOO 120 wio SO 141 176 7 7 wio2 92 849 783 40 33 msuitn 277 2889 3587 138 150 bath 135 891 353 19 15 upstairs living | 284 | 1451 | 3068 | 89 | 129 stairs | 50 | O | U | O | 0 Calculations approved bvACCA1omeet all requirements of Manual J8thEd. -p�- m��' Kn����� n�m�u *mun*°=�un,r�zo� nooe�s � uoIew�xy1u.croy '�� ' — '' . ~~ paoo� bed5 175 1925 2318 92 97 laundry 41 468 913 22 38 a/c 19 0 0 0 0 bath 3 96 791 558 38 23 hall 63 0 0 0 0 Entire House d 2651 28704 32540 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM 32540 Latent cooling 4144 TOTALS 2651 28704 36683 1367 1367 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Nov-29 10:27:09 I-S=_ wrightsofts Right-Suite@ Universal 2017 17.0.21 RSU25554 Page 2 ACCK ...press hornes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: E wrightsoft® DateProject Summary Job: : Entire House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project Information For: DR Horton Lot 9 Blk 12 Silverado, Zephyrhills, FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22114 Btuh Structure 23550 Btuh Ducts 6590 Btuh Ducts 8990 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh PIPT9 0 Btuh Equipment load 28704 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 32540 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central vent (0 cfm) 0 Btuh Heating Coolin (none) Area(ft2) 26N 2651 Equipment latent load 4144 Btuh Volume(ft3) 22094 22094 Air changes/hour 0.22 0.11 Equipment total load 36683 Btuh Equiv.AVF(cfm) 81 41 Req.total capacity at 0.75 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47OF Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=33 OF Backup: Input=9 kW, Output=29290 Btuh, 100 AFU E Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right-Suite®Universal 2017 17.0.21 RSU25554 2018-Nov-29 10:27:09 leuk press homes\Hayden 4EHB 2805-2nd fl block.rup Cale=MJ8 House Front faces: E Page i ... FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page)and an input summary checklist that can be used for field verification (usually four pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 11/29/2018 10:26:10 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 PASCO COUNTY BUILDING CONSTRUCTION SERVICESPASC "WE 8731 Citizens Drive Date:6/26/2019 CO-uNt' YFLORIDA11P� .8pi,te­23 0 Opnq S11ACES, kt!�[B NT PLACIRS. New Port Richey,FL 34654 727-8474126' R A NOT A PERMIT Receipt#: 11869477' FEE DESCRIPTION ACCOUNT CODE MMI4 INVOICE# FEE AMOUNT- PAID RECEIPT.# DATE Impact'Fee Residential Solid 24503100-3200.10 11.06 1473425 $32.11 $32.11 1869417 6/26/19 Waste Single,Family TOTALS: $32.11 $32.11, Receipt'# Paid By Check CC Auth# Cashier ID Workstation' Receipt Date Amt Paid 1869477 Check 936231 SLIEBLANC BCCCP06W 06/26/2019 Total Payments: $32.11 ERM Address Phone DR Horton, Inc. 1341'Horton Circle Arlington TX 76011 Comments: City of Zqphyrhills.Solid Waste: Address:6865 Wagon Trail Street LA Parcel ID:05 26 21 0100 01200 0090 White you will be paying your bill with Paico County Building construction Services,the full amount of the credit card or e­check fees,NOT shown above,is collected by First Sitting payment services. Myreports/reports//PASCOPROD/PASCOIRer,elotAAk V7.rpt 6126/2019 Page 1 of 1