Loading...
HomeMy WebLinkAbout19-20857 r CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20857 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20857 Address: 37422 LAUREL HAMMOCK DR Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Square Feet: Subdivision: OAK RUN Est.Value: Parcel Number: 34-25-21-0130-00000-0410 Improv. Cost: 5,263.67 OWNER INFORMATION Date Issued: 3/05/2019 Name: BISHOP, ROB & STACY Total Fees: 105.00 Address: 37422 LAUREL HAMMOCK DR Amount Paid: 105.00 ZEPHYRHILLS, FL. 33541 Date Paid: 3/05/2019 Phone: 727-470-1337 Work Desc: REPLACE 4 WINDOWS S/S CONTRACTORS APPLICATION FEES POWER HOME REMODELING GROUP LLC BUILDING FEE 105.00 P I i Ins ections Required FOOT ER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. ' CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit,there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. COnIRA&OR SIGNATURE PERMIT OFFICZR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20857 BUILDING PERMI PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20857 Addr ss: 37422 LAUREL HAMMOCK DR Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Tow hip: Range: Book: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s). Block: Sec ' Square Feet: Subdivi ' n: OAK RUN Est. Value: Parcel Num - 0-00000-0410 Improv. Cost: 7 1 OWNER INFORMATION Date Issue Name: BISHOP, ROB & STACY Total s: 105.00 Address: 37422 LAUREL HAMMOCK DR (Amofftid: ZEPHYRHILLS, FL. 33541 Daid: Phone: 727-470-1337 Desc: REPLACE 4 WINDOWS S/ CONTRACTORS APPLICATION-FEES POWER HOME REMODELING GROUP BUILDING FEE 105.00 kd 2 �� Ins ections Required FOOTER 2 D ROUGH PLUMB MISC INSULATION EI I FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC, DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first rinspection,whichever is greater,for each such subsequent reinspection. , NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. &_, k,4 CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permittln 813 546 _ 4496 DTI-rrrrr . . . Owner's Name Stacy and Rob Bishop Owner Phone Number (727)470-1337 Owner's Address 37422 Laurel Hammock Dr Owner Phone Number Fee Simple Titleholder Name Owner Phone Number . Fee Simple Titleholder Address JOB ADDRESS 37422 Laurel Hammock Dr,Zephyrhills FL 33541 LOT# SUBDIVISION PARCEL ID# County Employee, Not available (OBTAINED FROM PROPERTY TAX NOTICE) /� A$ U WORK PROPOSED B NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH V INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Remove and replace 4 windows-size for size BUILDING SIZE SO FOOTAGE HEIGHT ®BUILDING $ 5263.67 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY 0 W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION �� =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# OTHER V COMPANY Dan Price-Power Home Remodeling SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address 4135 Crescent Park Dr Riverview 33578 License# I CRC1331654 IIIIIIIIIIIIIIIIIIIII1111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)PIGI Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwaler Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal dale. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.Al commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel, alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) /��/ // fin/_ OWNER OR AGENT CONTRACTOR JCt� 1 l i L`e- Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who is/are personally known to me or has1have produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No.(11b1�7 7 V(J Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Edward Gilbert COMMISSION#MUM DI NHS;August 9,2M IondldtlMi11Y1011 Mohry City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 94 Y1 f r i u JOLA)tr V o ykt �e mad)) Date Received: Site: 3 -yob 02 LA y ' Ph m YhoG r Permit Type: N1 �, /tip Approved w/no comments:❑ Approved w/the below.comments: Denied w/the below comments: ❑ C-e P This comment sheet shall dkept with the permit and/or plans. FEB 2 0 2019 Kalvin Switz Plans Examiner Date Contra or d/or Homeowner (Req ' ed when comments are present) ivauonai rieaaquariers oiduy dnu ouu 01w1up 2501 Seaport Drive,Chester, PA 19013 33-57303 ' 888-736-6335 December 05, 2018 WWW.POWERHRG.COM CRC1331654 pD�f- PRODUCT SPECIFICATIONS pf YODiLIpD Buyer(s)'Information and Description of the Property: Project Number: 33-57303 December 05,2018 Stacy Bishop Date of Agreement Bob Bishop (863)529-9983(Stacys Cell) LADYTAY01 @GMAIL.COM 37422 Laurel Hammock Drive E-Mail Address i Zephyrhills, FL,33541 County:Pasco Township: Buyer(s) listed above hereby jointly and severally agrees to purchase the goods and/or services listed on the accompanying specification sheets, in accordance with the prices and terms described in the Custom Remodeling and Improvement and the Product Specifications (collectively,this"Agreement"). Pre Installation Inspection Date: Your pre installation inspection is tentatively scheduled for Tue 12/11 between 11:00a and 12:00p. Windows-WinForce Duraglass Inclusions:All windows meet Florida State product approval.This includes reinforcement, nighttime safety locks (on Double Hung windows only), double locks(on Double Hung and Slider windows only), welded corners, Heatshield 70, Duraglass, installation, clean up and haul away of all job-related debris. It is agreed and understood by and between the parties that the Product Specifications, along with the Custom Remodeling and Improvement Agreement, constitutes the entire understanding between the parties, and replace any and all prior negotiations, representations, or agreements, either written or oral. The Product Specifications may not be changed, modified, or varied in any way unless such changes are in writing and signed by both Buyer(s) and Contractor. Buyer(s) hereby acknowledge that Buyer(s) has read the Product Specifications. I have read and received each page of this 2 page agreement. Power Home Remodeling Group Buyer(s) Buyer(s) /12/05/18 /12/05/18 /12/05/18 Signature of Remodeling Consultant Signature Signature Brandon Rose Stacy Bishop Bob Bishop YOU,THE BUYER(S), MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION.SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. December 05, 2018 20:44 ivanonai rieaaquariers aiaoy anu Duu oitinuN 2501 Seaport Drive,Chester, PA 19013 33-57303 888-736-6335 December 05, 2018 ® WWW.POWERHRG.COM g CRC1331654 PEIIODELINO Project Specifications Windows: Dining Room-UR 1 17.0"x61.5" WINDOWS: Models WinForce Duraglass Styles Double Hung Types None Configs None 4 OPTIONS: Color White/White: Grid Pattern : None I Removal Block I Additional Details None r Windows: Dining Room-UR 1 17.0"x61.5" WINDOWS: Models WinForce Duraglass Styles Double Hung Types None Configs None OPTIONS: Color White/White: Grid Pattern : None 1 Removal Block 1 Additional Details None 4 t ffi Windows: Dining Room-M 1 51.25"x61.5" WINDOWS: Models WinForce Duraglass Styles Double Hung Types None Configs None OPTIONS: Color White/White: Grid Pattern : None 1 Removal Block 1 Additional Details None J Windows: Master Bedroom 1 73.0"x61.5" WINDOWS: Models WinForce Duraglass Styles Slider Types 2-Lite Configs None ~---~ ~—y OPTIONS: Color White/White: Grid Pattern : Colonial : Standard I Removal Block I Additional Details I J ? None r j December 05, 2018 20:44 Ivauonai heaaquarters OLUL;y dllU DUD DIJIIUI.1 2501 Seaport Drive,Chester, PA 19013 33-57303 888-736-6335 December 05, 2018 ® WWW.POWERHRG.COM CRC1331654 „DM CUSTOM REMODELING AND IMPROVEMENT AGREEMENT P[4ODELIM3 Buyer(s)'Information and Description of the Property: Project Number: 33-57303 December 05,2018 Stacy Bishop Date of Agreement Bob Bishop (863)529-9983(Stacys Cell) LADYTAY01 @GMAIL.COM 37422 Laurel Hammock Drive E-Mail Address 1 Zephyrhills, FL,33541 County:Pasco Township: Buyer(s) listed above hereby jointly and severally agrees to purchase the goods and/or services of Power Home Remodeling Group and its vendors ("Contractor") in accordance with the prices and terms described in this 6 page document and the Product Specifications, which are incorporated as part of the Agreement(collectively, this"Agreement"). This Agreement represents a cash sale of goods and services. Buyer(s) agrees to pay the cost of the goods and services purchased as described herein, regardless of timing or approval of any financing Buyer(s) may seek for their purchase. Purchase Price: $5,262.67 Pre Installation Inspection Dates: Down Payment: $0.00 Tue 12/11 between 11:00a and 12:00p Balance Due on $5,262.67 Estimated Project Start: 8 to 10 weeks Substantial Completion: Estimated Project Completion: 1 to 2 days Method of Payment: Other Buyer(s)acknowledge that a definite start and completion dates are NOT of the essence. Delays beyond! Contractor's control not included in calculating time frames. See Delay/Unknown Conditions. Buyer(s) hereby acknowledges receipt of a copy of the pamphlet, "The Lead-Safe Certified Guide to Renovate Right", informing Buyer(s) of the potential risk of lead hazard exposure from renovation activity to be performed in or at Buyer(s)' Property, at the address written above. Buyer(s) received this pamphlet on the date of this Agreement, before commencement of work. Buyer(s)' Initials. This Agreement constitutes the entire agreement and understanding between the parties, and this Agreement replaces any and all prior negotiations, representations, or agreements, either written or oral. No amendment, modification or waiver of this Agreement shall be valid or effective unless in writing and signed by both parties. Buyer(s) hereby acknowledges that Buyer(s) 1) has read the entire Agreement and has received a completed, signed, and dated copy of this Agreement, including the two accompanying Notice of Cancellation forms,on the date first written above and 2) was orally informed of his/her right to cancel this transaction. Notice To Owner a. Do not sign this home improvement contract in blank. b. You are entitled to a copy of the contract at the time you sign. Keep it to protect your legal rights. c.This home improvement contract may contain a mortgage or otherwise create a lien on your property that could be foreclosed on if you do not pay. Be sure you understand all provisions of the contract before you sign. Buyer(s) also agrees and understands that if Buyer(s)finances the work with a third-party, the terms of that financing will be contained on separate documents, including any finance charge. Future promotions not applicable. I have read and received each page of this 6 page agreement. Power Home Remodeling Group Buyer(s) Buyer(s) /12/05/18 /12/05/18 /12/05/18 Signature of Remodeling Consultant Signature Signature Brandon Rose Stacy Bishop Bob Bishop YOU,THE BUYER(S), MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. December 05, 2018 20:44 Ivanonai meaaquarters OLEAL;y d11U DUU DIJIIUP 2501 Seaport Drive,Chester, PA 19013 33-57303 888-736-6335 December 05, 2018 WWW.POWERHRG.COM w CRC1331654 NNE- CUSTOM REMODELING AND IMPROVEMENT AGREEMENT PFYDDEIIN'v Additional Terms & Conditions (continued) Additional Terms & Conditions ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW(SECTIONS 713.001-713.37, FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS KNOWN AS A CONSTRUCTION LIEN.IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS,SUB-SUBCONTRACTORS, OR MATERIAL SUPPLIERS,THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL.IF YOU FAIL TO PAY YOUR CONTRACTOR,YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY.THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF,YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE,YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX,AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND PAYMENT, UP TO A LIMITED AMOUNT, MAY BE AVAILABLE FROM THE FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND IF YOU LOSE MONEY ON A PROJECT PERFORMED UNDER CONTRACT,WHERE THE LOSS RESULTS FROM SPECIFIED VIOLATIONS OF FLORIDA LAW BY A LICENSED CONTRACTOR. FOR INFORMATION ABOUT THE RECOVERY FUND AND FILING A CLAIM,CONTACT THE FLORIDA CONSTRUCTION INDUSTRY LICENSING BOARD AT THE FOLLOWING TELEPHONE NUMBER AND ADDRESS: Construction Industry Licensing Board 2601 Blairstone Road Tallahassee, FL 32399-10, Phone 850.487.1395 ANY CLAIMS FOR CONSTRUCTION DEFECTS ARE SUBJECT TO THE NOTICE AND CURE PROVISIONS OF CHAPTER 558, FLORIDA STATUTES. Delay/Unknown Conditions: Contractor's failure to perform any term or condition of this Agreement as a result of conditions beyond its control such as, but not limited to strikes, fires, floods, acts of God, manufacturer's delay, material shortages, Buyer(s)' inability to qualify for or obtain financing, delays by local government authorities in issuing or otherwise approving inspections, permitting, or other required authorizations do not constitute abandonment and are not included in calculating time frames for performance by Contractor. Contractor and Buyer(s) have determined that a definite start and completion date are not material terms of this Agreement.The Buyer(s) understand that the start date and completion date are approximate and are subject to change. Late Payment/Late Cancellation of this Agreement: Buyer(s) agrees to pay a late fee of 1 1/2% per month on all amounts due and owing from Buyer(s)to Contractor accruing from the date due and running to the date the payment is made. In the event that Buyer(s) breaches any of the terms and/or conditions of this Agreement, Contractor may recover any damages for the breach thereof and all remedies in its favor existing at law. A Late Cancellation after midnight of the cancellation date, specified in this agreement, is a breach of this Agreement. The Buyer(s) shall reimburse Contractor for all of Contractor's out-of-pocket expenses, including, but not limited to, costs incurred by the Contractor for measuring, ordering, manufacturing, purchasing and administrating the procurement of the goods and services identified in this Agreement, and all other damages available under the law. Contractor's Right to Cancel: In the event that Contractor determines that this Agreement cannot be performed as intended by the parties due,for example, to incorrect pricing, unforeseen structural defects, or pre-existing conditions to Buyer(s)' Property, Contractor may cancel this Agreement within forty-five (45) days of its execution, notify Buyer(s) of such cancellation in writing and return all monies paid by Buyer(s). No Set-Offs or Retentions: Upon Substantial Completion of Contractor's work under this Agreement, Buyer(s) shall pay all amounts due under this Agreement without any right of set-off or retention. Substantial Completion is defined as the stage in the progress of the work where the work is sufficiently complete in accordance with this Agreement so that Buyer(s) can occupy or utilize the work for its intended use. If after paying all amounts due under this Agreement, Buyer(s) alleges that Contractor's work is defective in any respect, Contractor, without waiving any of its rights, shall cause an inspection of the work and perform any remedial work to the extent the Buyer(s) is entitled to under this Agreement or Contractor's warranty at no cost to Buyer(s). Buyer(s)' Representations and Responsibilities: In addition to making timely payment to Contractor according to the terms and conditions of this Agreement, Buyer(s) represents and warrants that(a) Buyer(s) owns the premises where the products and/or December 05, 2018 20:44 ivauonai rieaaquariers Otuuy anu Duu DranuN ' ,2501 Seaport Drive Chester, PA 19013 33-57303 888-736-6335 December 05, 2018 s WWW.POWERHRG.COM k' CRC1331654 ppME-- CUSTOM REMODELING AND IMPROVEMENT AGREEMENT pf NOOE LIYe Additional Terms & Conditions (continued) services are being provided by Contractor; (b) Buyer(s) will control, secure, and otherwise keep all pets away from the Contractor and the work areas; (c) Buyer(s) will not allow unattended minors at the Property while the work is being performed; (d) Buyer(s)will provide Contractor with unrestricted access to the premises at all reasonable times for the purposes of taking measurements, performing the work, and for any subsequent remedial work, if required, including access to electrical outlets as may be.required by Contractor; (e) Buyer(s) will remove, secure, or otherwise protect all items of value or concern to avoid any accidental mistakes or slippages as the Contractor will not be liable for replacing or repairing other household items in the work areas; (f) Buyer(s) shall be responsible for the preparation, moving, and reinstalling of all wiring, water lines, power lines, plumbing, and the moving of any shrubs, plants, or other items as required by Contractor under this Agreement; and (g) if Contractor's work requires consent and/or approval from any Homeowner's Association or any other legal entity or voluntary association that enforces covenants, conditions, and restrictions on property(including designated historic sites), Buyer(s) is responsible to submit any required forms and obtain approval for the work to be done and to keep Contractor informed as to the approval status. Contractor's Responsibility: Contractor shall obtain any necessary permits and provide the Buyer(s) with a certificate of occupancy, if required. Contractor accepts no responsibility for any damage resulting from structural or other defects in the Property at which work is performed under this Agreement. Contractor is not responsible for remedying structural defects and other pre- existing conditions in or at Buyer(s)' Property. Buyer(s) acknowledges that Contractor's products do not correct or cure pre-existing problems such as leaks, lead, mold, asbestos, dry rot, decay, fungi, termites, and/or other structural and/or environmental problems. Contractor shall not be responsible for(a) any damages arising in whole or in part from strikes, fires, accidents, floods, governmental actions, or any other causes beyond control of Contractor; (b) any damages including without limitation, lost profits, or reduction in value of the premises, arising from Contractor's delay in performing under this Agreement or due to its breach of this Agreement; (c) unintentional damage to window treatments, shutters, blinds, alarm systems, household items, landscaping, satellite dish, gas lines, condensation pipes, electrical wiring, plumbing, and telephone installations, it being understood that Buyer(s) is responsible at its own cost for all preparations, protection and/or moving of such items prior to Contractor's commencement of the work; (d) collateral or incidental damage to interior walls (including wall tiles) and personal property, including damage occurring as a result of Contractor installing products on or in Buyer(s)' Property, it also being understood that Buyer(s) is responsible at its own cost for all preparations, protection and/or moving of such items prior to Contractor's commencement of the work; and (e) removing and/or refitting/reconnecting Buyer(s)' home security system or the costs associated with removing and/or refitting/reconnecting Buyer(s)' home security system, it being understood that Contractor will attempt to work around any home security system on the premises. Mold and Related Matters: Buyer(s) agrees to defend, indemnify and hold Contractor and its employees, agents, and vendors harmless from any claims as to the identification, detection, abatement, encapsulation, or removal of mold, asbestos, lead-based products, or other hazardous substances inside or outside of the Property at which work is performed. Contractor does not provide mold testing or remediation services. Excessive humidity, lack of ventilation and/or extreme temperature differences may result in excessive condensation to appear on or around windows, in walls, or in attics. Products that Contractor is installing do not create moisture or excessive humidity;thus, Contractor is not responsible for condensation. Warranties: Buyer(s) understands that Contractor will make available to Buyer(s) all product and labor warranties offered in connection with this Agreement. Buyer(s) understands that Buyer(s) should read all warranties for complete details of coverage. Complete copies of applicable product warranties are available for review by Buyer(s) at any time by visiting https:Hpowerwarranties.com. Buyer(s) acknowledges that the labor warranty was presented at the time this Agreement was signed and a copy of the warranty was given to Buyer(s). Buyer(s) understands that no warranty will be effective while a balance due remains on this Agreement. Lien Rights: In the event that Buyer(s)does not pay Contractor any of the money owed when it is due, Contractor may have a claim against Buyer(s)that may be enforced against Buyer(s)' Property in accordance with applicable lien laws. Buyer(s) also understands that if Buyer(s)finances the work with a third party, Buyer's separately provided other documents may include a security interest. Buyer(s) understands that Buyer(s) should read those documents closely. Miscellaneous: No waiver of any breach of this Agreement shall be construed as a waiver of any prior, concurrent, or subsequent breach hereof. The section headings contained in this Agreement are inserted for convenience only and shall not affect in any way the meaning or interpretation of this Agreement. In construing this Agreement,the gender and number of words used may be changed to meet the context. No alteration to or deviation from this Agreement, including those that change the cost, materials, work to be performed, or estimated completion date, will be valid without the signed, written consent of both Buyer(s) and Contractor. This Agreement is to be governed by the laws of the state in which it is performed, except as may be preempted by federal law.Any part of this Agreement contrary to the law of this state shall not invalidate other parts of this Agreement. If a provision of this Agreement is held December 05, 2018 20:44 111111111111 IIH IIIIIIIII IIIIII 111111111111111111111111111 rvauonai r1eaaquariers Macy anu ovu oisnuN 2501 Seaport Drive,Chester, PA 19013 33-57303 888-736-6335 December 05, 2018 WWW.POWERHRG.COM CRC1331654 pDp=- CUSTOM REMODELING AND IMPROVEMENT AGREEMENT pEp0D6llpa Additional Terms & Conditions (continued) to be invalid or unenforceable,this Agreement shall continue in full force and effect and shall be construed as if the invalid or unenforceable provision was omitted. December-05, 2018 20:44 National rleaaquarters XOLUUy 411U DUU DI511Up m 2501 Seaport Drive,Chester, PA 19013 33-57303 888-736-6335 December 05, 2018 M WWW.POWERHRG.COM CRC1331654 IIOYf------ CUSTOM REMODELING AND IMPROVEMENT AGREEMENT Pf YO DF LI X,. Notice of Cancellation NOTICE OF CANCELLATION C�,� NOTICE OF CANCELLATION DATE OF TRANSACTION: December 05, 2018 DATE OF TRANSACTION: December 05, 2018 YOU MAY CANCEL THIS TRANSACTION, WITHOUT YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE ANY PENALTY OR OBLIGATION,WITHIN THREE BUSINESS DAYS FROM THE ABOVE DATE. IF YOU BUSINESS DAYS FROM THE ABOVE DATE. IF YOU CANCEL, ANY PROPERTY TRADED IN, ANY CANCEL, ANY PROPERTY TRADED IN, ANY PAYMENTS MADE BY YOU UNDER THE CONTRACT PAYMENTS MADE BY YOU UNDER THE CONTRACT OR SALE, AND ANY NEGOTIABLE INSTRUMENT OR SALE, AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN 10 EXECUTED BY YOU WILL BE RETURNED WITHIN 10 DAYS FOLLOWING RECEIPT BY THE SELLER OF DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELED. IF YOU CANCEL, YOU MUST MAKE BE CANCELED. IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE, IN AVAILABLE TO THE SELLER AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE; OR YOU MAY, IF YOU THIS CONTRACT OR SALE; OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLERS EXPENSE AND RISK. THE GOODS AT THE SELLERS EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN 20 DAYS OF THE DATE OF YOUR NOTICE OF WITHIN 20 DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. THE GOODS WITHOUT ANY FURTHER OBLIGATION. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM, POWER HOME NOTICE, OR SEND A TELEGRAM, POWER HOME REMODELING GROUP, 2501 SEAPORT DRIVE, REMODELING GROUP, 2501 SEAPORT DRIVE, CHESTER PA 19013, NOT LATER THAN MIDNIGHT OF CHESTER PA 19013, NOT LATER THAN MIDNIGHT OF December 10, 2018. December 10, 2018. 1 HEREBY CANCEL THIS TRANSACTION 33-57303 1 HEREBY CANCEL THIS TRANSACTION 33-57303 1 Bishop,Stacy Bishop,Stacy Date Date December 05, 2018 20:44 ***Please mail Certified Copy to contractor's address*** Illllll}Il}}ll}I}Ill4lllllll11111111i11111111111111illlllll} NOTICE OF COMMENCEMENT 2019003415 (,l Permit Number Tax Folio# / `u The undersigned hereby gives notice that improvement will be made to Rep{,;2018740 Rec: 10,00 certain Real Property, and in accordance with Chapter 713,Florida IT: 0.10 Statutes,the following information is provided in this Notice of Commencement. D5: 0.00 Clerk 01/08/2019 C. F. , Dpty 1. DESCRIPTION OF PROPERTY: (Legal description ilable). PRULR S.O'VEIL,Ph.D.PRSCO CLERK & COMPTROLLER te L� , WS 01/08/2019 10:52am 1 of 1 3_sC/ OR BK gg4� Pj 3759 2. GENERAL DESCRIPTION OF IMPROVEMENT: Remove and replace </4,z--_du4,f>5—Z,at ZR This space reserved for recording 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LE7 SEE CONTRACTED FOR THE IMPROVEMENT: Name&Address: e� l�>�ZoD p4,Y(s Interest in Property: Remove and re lace yws,.�u-riS Fee Simple Title Holder(if different from owner listed above): 4. CONTRACTOR: Name: Dan Price-Power Home Remodeling Phone Number: 610-874-5000 x4037 Contractors Address: 4135 Crescent Park Dr Riverview FL 33578 S. SURETY(if applicable,a copy of the payment bond is attached):Amount of bond: $ Name: Phone Number: Address: 6, LENDER'S NAME: Phone Number: Lender's address: 7. Person's within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713,13(1)(a)7., Florida Statutes. Name: Phone Number: Address: 8. In addition, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number of person or entity designated by Owner: 9. Expiration of notice commencement (the expiration date will be 1 year from date of recording unless a different date is specified. 20, WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. i.._.-,..,. RAJ, :N _� SC rV i hf ( ig ure of Owner ssee,or Ow see's rint Name d Provide Signatory's ntl /Office) A ho r hector/Partner/Manager) State of Florida County of C-,� Township: GlS The foregoin instrument as acknowledged before me this day o 20./0 by t' forr,2 rt o Qrz (type of authority,...e. .offcer,trust orney in fact) (name of party on be/half of v Aom�nstrument was executed) Personally Kno r Produced Identification (Signature o is—State of Florida) Commission f GGISM18 .j.,• Expires:November 8,2021 Prepared by: Michael George , Bonded thmAam tlotary Plan Review Windows & Doors 1) Need manufacturing installation specifications: 2) Must meet sections R308 and R612 of the 2017 F:B.C. 3). If windows are to be installed inside the historical district,they will need to be-approved by th6 historicaI committee: 4) No other work shall be permitted (framing, plumbing, and mechanical) unless otherwise specified.: 5) This is for replacement (glass for glass) only. If you wish to change from screen or vinyl windows to glass-,then additional information is required. 6) All windows to wall connections shall be left visible for. inspection: 7) All labeling.and stickers shall remain on windows until final inspection. 8.) No work shall start without permit first. Application #: Pasco County Product Approval Specification Cover Sheet -' As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. NOTE: It is the responsibility of the permit holder to have the printed installation instructions on the 'obsite -- �- p Y p p J for the inspector's verification. Florida approved products are listed online at www.florid abuilding.o[g or.can be obtained from local product supplier. WINDOWS AND DOORS Symbol Number Product Product Manufacturer, Series or Fl or Miami Width Height Positive Negative. on Plan of Units, Category Subcategory Model# ! Approval# Pressure Pressure. PP Example: j I O 3 Window D ble Hung NBP i 22300.2 O 1 Windowr NBP � � 22293.2 O ! ! _._:_._W .. .......... . - ._..._.............._...- ----- ...__........_................--- -......_..-... -.._...................__. _...................._..._.__._..._..... ���0 ! - - -._..._ . �.-_ 3 .�- -------=-----._._.�__ =- --._..._-....._T . -- --- --- ----_...--- - _._..... - y �n A. Y 2 i ( d P ! OTHER(ROOFING,SIDING,.SOFFIT,.FASCIA, ETC.) USE ADDITIONAL SHEETS AS NEEDED SUBMIT TWO (2)COPIES WITH PERMIT APPLICATION E 12 VV3 4 UGP=271 PAS=816 S24 324 N24 E12 VV18 E34 FOP=72 Window S4 N4 A E18 This is a acceptable Site plan submittal, to be included with the product approval cover sheet for windows; and can be obtained from the Pasco County Properly Appraiser web site 8/10/2018 Florida Building Code Online BCIS Home I Login I User Registration Hot Topics ! Submit Surcharge Stats&Facts I Publications Contact Us E BCIS Site Map f Links Search db r Product Approval P 1;: USER:Public User Product Aooroval Menu>Product or Apoilcanon Search>Agnlicatlon List>Application Detail «gym YM FL# FL22293-R2 n ? Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments public comment:Ext.Ann.Lite does not comply w/2411.1.11.05/18/18 Archived Product Manufacturer Northeast Building Products Inc. Address/Phone/Email 4280 Aramingo Ave Philadelphia,PA 19124 (215)535-7110 L.Knowles@nbpmail.com Authorized Signature Lucas Turner Luke@TurnerEC.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Scott Wolters,PE : ; Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E 1886 2005 ASTM E 1996 2009 TAS 201/202/203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 03/13/2018 Date Validated 04/05/2018 littps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquYPIHVagbgMSirRyI l4oTUDmOyUStI%2bG6u0wkbORXKLw%3d%3d 112 8/1 0120 1 8 Florida Building Code Online Date Pending FBC Approval Date Approved 04/11/2018 Summary of Products FL# Model,Number or Name Description _.._._--_......._............_..--..-......-.._.. 22293.1 WinForce Horizontal Slider Impact WinForce PVC Horizontal Slider XX and XOX Window,Large Missile Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes ; FL22293 R2 C CAC 86-155 .AR.pdf Approved for use outside HVHZ:Yes I FL22293 R2 C CAC 86-163CAR.pdf Impact Resistant:Yes ( FL22293 R2 C CAC 86-199CAR.pdf Design Pressure:N/A Fl 27 R CAC 86- 0-3 AR pdf Other:Please see Certifications,Installation Instructions,and FL22293 R2 C CAC 86-210CAR.pdf Evaluation Report for additional Information,design pressures, FL22293 R2 C CAC 86-212CAR.pdf and configurations that are approved for the HVHZ. FL22293 R2 C CAC 86-213CAR pdf FL22293 R2 C A . 86- 7 AR.Of FL22293 R2 C CAC86 O .AR.pdf FL22293 R2 C CAC 86-401CAR.pdf FL22293 R2 C CAC 86-406CAR.pdf EL22293 R C CAC 86-408 .AR.pdf FL22293 R2 C CAC 86-416CAR.pdf FL22293 R2 C CAC86-418 AR.pdf FL22293 R2 C' CAC 86-4 4 AR.pdf F I 7 93 R2 C CAC 86-435CAR.pff Quality Assurance Contract Expiration Date 01/31/2021 Installation Instructions FI77793 RZ Ii FPA-WinFor -S -1 M-B.pdf Verified By: Lucas A.Turner PE#58201 Created by Independent Third Party:Yes Eva Iuation,Reports FL2 93 R2 AF FvalRepnrt-WlnForcP-1,1-I M-B.pdf - -- — -- Created by Independent Third Party:Yes ___-[ 22293.2 WinForce Horizontal Slider Non- WinForce PVC Horizontal Slider XX and XOX Window,Non- Impact Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22293 R2 C CAC 86-154CAR.pdf Approved for use outside HVHZ:Yes FL22293 R2 C CAC 86-168CAR.pdf Impact Resistant:No FL22293 R2 C CAC 86-400 AR.pdf Design Pressure:N/A FL22293 R2 C CAC 86-402CAR.pdf Other:Please see Certifications,Installation Instructions,and F 7 3 R CAC 86-405 .AR.pdf Evaluation Report for additional information,design pressures, FL22293 R2 C CAC 86-407 AR.pdf and configurations that are approved for the HVHZ. FI 27293 R2 C CAC 86-420CAR.pdf FL22293 R2 C CAC 86-4 3 AR.pdf FL22293 R2 C CAC86-433 .AR.pdf FL22293 R2 C CAC 86-436 AR.pdf Quality Assurance Contract Expiration Date j 01/31/2021 Installation Instructions FL22293 R2 II FPA-WinForce-SL-NI-B.pdf Verified By: Lucas A.Turner PE#58201 Created by Independent Third Party:Yes Evaluation Reports FL22293 R2 AE EvaIR port-WinForce-SL-NI-B.pdf Created by Independent Third Party:Yes Back Next Contact Us;;2601 elalr Slone Road,Tallahassee FL 32399 Phone;850-487-1824 The State of Florida is an AA/EEO employer.CQpy119ht 2007-2013 Stale of Florida.;;Privacy Statement::Access!b!!IN Statement;;Refund Statement Under Florida law,email addresses are public records,If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click leery_. Product Approval Accepts: `,t�.t" �il tCF.gtA 0 Credit Card Safe https://www.floridabuilding.org/pr/pr-app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bgMSirRyl14oTUDmOyUStI%2bG6uOwkbORXKLw%3d%3d 2/2 GENERALNOTES WINFORCE HORIZONTAL SLIDER WINDOW 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMANVDMA/CSA NON-IMPACT 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA APPROVED CONFIGURATIONS BUILDING CODE,6TH EDITION(2017). CONFIGURATIONS NOTED AS HVHZ DESIGN APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE ACCEPTABLE REQUIRED HVHZ IMPACT FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. CONFIGURATION GLAZING' APPROVED PRESSURE RATING 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT RATING PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 74"x63"XX 2SL TYPE A YES +50/-50 PSF 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING AREAS LIMITED 84"x66"XX 2SL TYPE B YES +50/-50 PSF BY ASTM E-1300 GLASS TABLES,AND TESTED WATER AND STRUCTURAL 104"x66"XOX EQUAL LITE TYPE A YES +50/-50 PSF PRESSURES. 4.THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE THE 93"x66"XOX 1/4-1/2-1/4 TYPE ASASH YES +55/-55PSF NONE INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE TYPE B FIXED CONFIGURATIONS SHOWN IN THE ELEVATIONS. 'X'INDICATES OPERABLE 104"x66"XX 2SL TYPE B NO +40/40 PSF PANEL,'O'INDICATES FIXED PANEL. INSTALL PRODUCTS WITH MAXIMUM SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT,AND WITH FASTENER TYPE AS SHOWN IN THE DETAILS AND AS INDICATED IN TABLE 1. 104"x66"XOX 1/4-1/2-1/4 TYPE B NO +40/-40 PSF FOR FULL PRODUCT CONSTRUCTION DETAILS SEE NCTL TEST REPORTS 210-4067-01/01A/01B/01C,AND 210-4081-01B/01C/02B/03B/04A/04C 'SEE GLAZING DETAILS,SHEET 2 5.APPROVED MINIMUM GLAZING IS AS SHOWN IN GLAZING DETAILS ON SHEET 2 AND AS SPECIFIED IN ALLOWABLE CONFIGURATIONS TABLE ON INSTALLATION 74"MAX.WINDOW WIDTH THIS SHEET. FASTENER 6"MAX. 10-1/2"MAX. 6.THE 413 ALLOWABLE STRESS INCREASE FACTOR(SHORT-TERM INCREASE LOCATION,TYP. ON CENTER, FROM FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS FOR THIS � CORNER, SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF ANCHORAGE NP TYP. INTO WOOD SUBSTRATE. 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS)AND ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND SHALL 32-5/8"MAX. _ BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR AS DLO,TYP. C9 APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). BUCKING, }a} w OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY DESIGNED& 0~ v = LUCKS INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO TRANSFER u;of X _ X 3 Turner SUPERIMPOSED LOADS TO THE STRUCTURE. WITH MASONRY OPENINGS, z p 2018-03-13 WOOD BUCKS ARE OPTIONAL. :E O ;'-! z 21:43+20:00 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE COATED OR OTHERWISE PROTECTED TO PREVENT GALVANIC REACTIONS. WOOD U IL BUCKS,IF USED,SHALL BE PRESSURE TREATED,WITH EITHER W TREATMENT OR COATING COMPATIBLE WITH THIS PRODUCT. U F- �`5•.�c£ s..L��.,,� 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING z SILL ANCHOR SPACING � Ito 5e2atT :�s COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL OTHER SAME AS HEAD WINDOW MATERIALS. 74"x63"XX 2SL ELEVATION 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH THESE %o'• 'L; DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BYA FLORIDA o ai..... `�n REGISTERED PROFESSIONAL ENGINEER ON ASITE-SPECIFIC BASIS. TABLE OF CONTENTS , ,U„,A;11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER SHEET DESCRIPTION NORTHEAST BUILDING PRODUCTS INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE 1 NOTES,ELEV., 4280 Aramingo Ave.,Philadelphia,PA 19124 i� RESPONSIBILITY OF OTHERS AND ARE NOTADDRESSED BY THIS CONFIG.TABLE Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 DOCUMENT. 2 ELEV.,GLAZING SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 3 XOX ELEV. NOTES,ELEVATION 4/13/2017 FL PE#58201 SHEET 5. 4 VERTICAL SECT. 1239 Jabara Ave. 5 HORIZ.SECTIONS SCALE: NTS REV:B_ North Port,FL 34288 6 BOM,PART DWGS DRAWING:FPA-WINFORCE-SL-NI SHEET: 1 OF Ph.941-380-1574 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT 84"MAX.WINDOW WIDTH 104"MAX.WINDOW WIDTH 8-1/4"MAX.O.C.,TYP. 12"MAX.O.C.,TYP. INSTALLATION CENTER OF INSTALLATION CENTER OF FASTENER INTERLOCK 6"MAX. FASTENER INTERLOCK 6"MAX. LOCATION,TYP. FROM LOCATION,TYP. FROM 3"3„ CORNER0 0 0 , 3"3„ CORNER, TYP. � TYP. <C� ON 0ON 0 000 0 0 0 0. 37-5/8"MAX. ::' 47-12"MAX. f- I i— DLO,TYP. C9 a0 DLO,TYP. c�7 0 � X X 3 U7� X X �� w �o z LL �o z o z_ �w C z � o za-� � " ED0 z0a `- w rul p SILL ANCHOR SPACING p SILL ANCHOR SPACING SAME AS HEAD SAME AS HEAD 84"x66"XX 2SL ELEVATION 104"x66"XX 2SL ELEVATION GED GED STAINLESS STEEL STAINLESS STEEL INTERCEPT SPACER 1/8"ANNEALED INTERCEPT SPACER 3/16"AN 1/8"ANNEALED GLASS 3/16"ANNEALED GLASS GLASS GE SCS2801 GLASS GE SCS2801 EXT SILICONE EXT. SILICONE �% roo 58201 'P 17 D 17 D 'p'. sr�re OF i4 <.O'FBC.SECT.2411.3.3.1 FBC.SECT.2411.3.3.1 COMPLIANT SETTING Cn w COMPLIANT SETTING w NORTHEAST BUILDING PRODUCTS BLOCKS i` F-? BLOCKS N I- ? z� �m� ��m g 4280 Aramingo Ave.,'Philadelphia,PA 19124 Ph.(215)535-7110 www.camelotwindows.com 311 212 01 8 SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. ELEVATIONS,GLAZING DETAILS 4/13/2017 FL PE#58201 TYPICAL GLAZING TYPICAL GLAZING 1239 Jabara Ave. DETAIL,TYPE A DETAIL,TYPE B SCALE: NTS REV:B North Port,FL 34288 DRAWING:FPA-WINFORCESL-NI SHEET. 2OF6 Ph.941-380-1574 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT 104"MAX.WINDOW WIDTH 104"MAX.WINDOW WIDTH INSTALLATION 9"MAX.O.C.,TYP. INSTALLATION 9"MAX.O.C.,TYP. FASTENER CENTER OF CENTER OF 6"MAX FASTENER CENTER OF CENT.OF 6"MAX. LOCATION,TYP. INTERLOCK INTERLOCK FROM LOCATION,TYP. INTERLOCK INTLO- 3" C�K{ FROM " "3" CORNER, 3„ I�3"g^ I CORNER, TYP. TYP. 31"MAX. �- 23"MAX.SASH DLO,TYP. _ o a DLO,TYP. .2 2 a "/ x = O � � X O X �� � � X O X � 3 W coo XW ' m0 p w i/ p W 47"MAX. / 3 fO U N U � CO U N U FIXED DLO p SILL ANCHOR SPACING SAME AS HEAD -p SILL ANCHOR SPACING SAME AS HEAD 104"x66"XOX EQUAL LITE ELEVATION 104"x66"XOX 1/4-1/2-1/4 ELEVATION 93"MAX.WINDOW WIDTH INSTALLATION 9"MAX.O.C.,TYP. FASTENER CENTER OF CENT.OF 6"MAX LOCATION,TYP. INTERLOCK IN3 LOCK FROM �—3" l—3� CORNER, I TYP. 20-1/2"MAX.SASH DLO,TYP. r No 58201 trP" 0 n . w X ^�y ' X O X ¢� Aso: srre OFLLJ ;mow Q Z 0 Z ��rveuttutN co o � w 41-1/2"MAX. 3 NORTHEAST BUILDING PRODUCTS N W FIXED DLO 4280 Aramingo Ave.,Philadelphia,PA 19124 �2 U Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 p SILL ANCHOR SPACING SAME AS HEAD SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. XOX ELEVATIONS 4/1 312 01 7 FL PE#58201 93"x66"XOX 1/4-1/2-1/4 ELEVATION 1239 Jabara Ave. SCALE: NTS REV:B North Port,FL 34288 DRAWING:FPA-WINFORCE-SL-NI SHEET: 3OF6 1 Ph.941-380-1574 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT SEE GENERAL ANCHOR NOTES,SHEET5. SEE TYPICAL GLAZING MIN.EDGE DIST., DETAIL,SHEET 2 SUBSTRATE APPLIES TO BOTH - EXT. INT. CLEARANCE EXT.AND INT.SIDES, z_w w_j 26 HOLE AND PLUG BY OTHERS, SEE TABLE 1 g a SEE TABLE 1 w H 6 D D INSTALLATION SEALANT BY 14 FASTENER,SEE INSTALLER TABLE 1,SEE 4 o O O LOCATIONS 1 SHEETS 1-3 3 11 _< 3 =c� 11 ` �a - `- n `-�cna 1 `n zwww cc w 14 INSTALLATION FASTENER,SEE SEALANT BY 6 TABLE 1,SEE INSTALLER 26 LOCATIONS SHEETS 1-3 a EXT SUBSTRATE CLEARANCE MIN.EDGE DIST., INT.D D - HOLE AND PLUG BY OTHERS, APPLIES TO BOTH SEE TYP.GLAZING SEE TABLE 1 EXT.AND INT.SIDES, SEE TABLE 1 DETAIL SHEET 2 TYPICAL HEAD VERTICAL SECTION TYPICAL SILL VERTICAL SECTION Pia 5B2Q7 :;n: TABLE 1:EQUAL LEG/FLANGE FRAME INSTALLATION ANCHOR REQUIREMENTS TABLE NOTE: ALL ANCHORS ARE PAN HEAD OR HEX WASHER HEAD9a SUBSTRATETYPE ANCHOR TYPE MIN.EMBED. MIN.EDGE DIST. Q�p�`�� f A CONCRETE(2.0 KSI MIN) 3/16"ITW TAPCON 1" 1 1/8" NORTHEAST BUILDING PRODUCTS HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" Z. 4280 Aramingo Ave.,Philadelphia,PA 19124 �Z CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 2X MIN.SOUTHERN PINE WOOD(G=0.55) #10 GRADE 5 WOOD SCREW 1-3/8" 1" SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. HEAD/SILL INSTALLATION 411 312 01 7 FL PE#58201 16 GAUGE(0.060")MIN.STEEL STUD,33KSI #10-16 HILT]KWIK-FLEX OR ITW 1/2" 1239-abara Ave. YIELD MIN.,OR 1/8"ALUM.6063-T5 MIN. TEKS SELF-DRILLING SCREW FULL SCALE: NTS REV:B North Port,FL 3428E DRAWING:FPA-WINFORCESL-NI SHEET: 4OF6 Ph.941-380-1574 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT 1/4"MAX. 1/4"MAX. SHIM SPACE SHIM SPACE MIN.EMBED., SEE TYPICAL MIN.EMBED., SEE TYPICAL SEE TABLE 1 1 13 25 6 GLAZING DETAIL, SEE TABLE 1 1 13 25 6 GLAZING DETAIL, SHEET 2 SHEET 2 m Uj !IW w �2 W pa_8 ❑ = a INT. W D_0 ca C� ❑ = o INT. ¢ m C m Wm Z_ :O pp ❑ IMP ❑ . ern ~W� � rA W� ❑ a o ❑ EXT. a Ems. 0 0 ° CLEARANCE CLEARANCE HOLE AND PLUG ° HOLE AND PLUG ❑ ❑ INSTALLATION _ ❑ ❑ INSTALLATION FASTENER,SEE FASTENER,SEE o TABLE 1,SEE o TABLE 1,SEE SUBSTRATE LOCATIONS SUBSTRATE LOCATIONS SHEETS 1-3 BY OTHERS, 2$ SHEETS 1-3 BY OTHERS, SEALANT BY SEALANT BY SEE TABLE 1 SEE TABLE 1 INSTALLER INSTALLER TYPICAL JAMB HORIZONTAL SECTION TYPICAL OPTIONAL ADD-ON FLANGE SECTION, JAMB SHOWN, MAY ALSO BE USED HEAD/SILL GENERAL ANCHOR NOTES: 1.INSTALL ONE ANCHOR AS INDICATED IN DETAILS ON SHEETS 4 AND 5 AT EACH LOCATION ' �+o sa2cT ��_ SHOWN IN THE ELEVATIONS ON SHEETS 1 THROUGH 3. 2.INSTALL SHIMS AT EACH ANCHOR LOCATION WHERE A GAP OF 1/16"OR GREATER EXISTS A' srATE OF '<v: BETWEEN PRODUCT FRAME AND SUBSTRATE. '.,0T1 3.SHIMS SHALL BE LOAD-BEARING(PLASTIC OR METALLIC)AND CAPABLE OF SSt . •• TRANSFERRING LOADS TO SUBSTRATE. ��``���ii.�ri+t``•� 4.SPECIFIED ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL FINISH OR NORTHEAST BUILDING PRODUCTS y STUCCO,BY OTHERS. FOR ATTACHMENT TO METAL SUBSTRATES ENSURE FULL THREAD 4280 Aramingo Ave.,Philadelphia,PA 19124 ENGAGEMENT THROUGH METAL WALL WITH MIN.3 THREADS BEYOND. Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 5.FOR MASONRY WITH WOOD BUCKS LESS THAN 1-1/2"THICK,EMBEDMENT SHALL BE SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. BEYOND WOOD BUCKS AND INTO MASONRY. WOOD BUCKS ARE OPTIONAL WITH MASONRY JAMB INSTALLATION/ALT.FLANGE - 4/13/2017 FL PE#58201 INSTALLATIONS WHERE MASONRY EDGE DISTANCE CONDITIONS ARE MET WITH NO BUCKS. 1239 Jabara Ave. WOOD BUCKS 1-1/2"THICK OR GREATER SHALL HAVE EMBEDMENT INTO THE WOOD BUCKS. SCALE: NTS REV:B North Port,FL 34288 6. ENSURE 3"MIN.ON-CENTER SPACING BETWEEN ANY TWO INSTALLATION ANCHORS. DRAWING:FPA-WINFORCESL-NI SHEET. 5 OF 6 Ph.941-380-1574 BILL OF MATERIALS WINFORCE HORIZONTAL SLIDER WINDOW, ITEM DESCRIPTION PART NO. SOURCE MATERIAL NON-IMPACT 1 HEAD/SILL/JAMB 10005163 DECEUNINCK PVC 2 3 HEAD/SILL TRACK INSERT 10300127 ASTRO SHAPES 6005-T5 ALUM. 411 4 HEAD/SILL TRACK INSERT COVER 10008469 DECEUNINCK PVC 32 5 6 CENTER FIN WEATHERSTRIPPING .187 BK.x.290 HT. ULTRA FAB FIN PILE rFnl 1� - 7 WSTRIP 1"STRIP @KEEPER INT'LCK .270 BK.x.270 HT.ADHESIVE ULTRAFAB FIN PILE O 31„ 8 CENTER FIN WEATHERSTRIPPING .187 BK.x.220 HT. ULTRAFAB FIN PILE 32 9 WEEP COVERS 900-003 LAWRENCE PLASTIC 10 11 HEAD/SILL TRACK SCREWS #8 x 5/8"PPH TEK MERCHANTS STEEL Cl) O OPF� min12 O 13 PULL STILE 10005541 DECEUNINCK PVC 1 14 TOPBOTTOM RAIL 10005539 DECEUNINCK PVC 15 KEEPER STILE 10005543 DECEUNINCK PVC 16 LOCK STILE 10005542 DECEUNINCK PVC 17 GLAZING BEAD-3/4"IG 10005456 DECEUNINCK PVC 18 19 ROLLER 1146 VISION POLYPROPJ BRASS 20 LOCK-DUAL TECH PASSIVE D2100AL-XX ASHLAND NYLON 21 LOCK SCREW #8 X 1"PAINTED PFH MERCHANTS STEEL 22 KEEPER 13999-999-XX ASHLAND TIN-ZINC 23 KEEPER SCREW #6 X 3/4"PAINTED PFH MERCHANTS STEEL 7. 1 24 I_L-L c%V 25 REINF.PULL&KEEPER STILE 10300159 ASTRO SHAPES 6005-T5 ALUM. 26 REINF.LOCK STILE&TOP/BOT.RAIL 10300266 ASTRO SHAPES 6005-T5 ALUM. 27 FIXED LITE FLANKER STOPS 29918 VISION NYLON 14 O O 28 ADD ON FLANGE 10008341 DECEUNINCK PVC SEE TYPICAL 16 26 21 20 22 12. 12"--{ GLAZING DETAIL ao �� CAN -N T.. �m `�9 0E"I L• MN NIA 25 ;van,�, sF,�-, 15 16 23. *` # *z 32 90: Srare of :1 . mow NORTHEAST BUILDING PRODUCTS 25 a 8 I 4280 Aramingo Ave.,Philadelphia,PA 19124 E Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 15 26 NAM 28 SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. BOM,PART DRAWINGS 4/13/2017 FL PE#58201 LOCK/KEEPER STILES DETAIL —� 23. 1239 Jabara Ave. 32 SCALE: NTS REV:B Ncri 1 Port,FL 34288 DRAWING:FPA-WINFORCE-SL-NI SHEET: 6 OF 6 Ph.941-380-1574 1/1 6120 1 8 Florida Building Code Online {{ °'+";„%N°Ca.{';v�alin„�°s�"RNs"?^'✓• (q'L�;1`�s'�•`" .�y�9��' �t„' �7'Y4 �,� Ott [..K.`"�>' w „. *t-'£ 3>;,��. T•k:Y' ,';(%�a s,tf 'a>I,-'� r'yx 6.,;^+'�. a a"'#€ , pp �`'` ' ,y;-'t`«3 s�'. ;;,:tis„�•"• { per'c.,,. !',';,,,,,�t�}"x...s„�,...£.: ... ....,."�': ry I.'_' .�._.v....,...,..�.,,�'��:...,._,...����.,.....,.,.. .,_.,....in.;.,r"'"s.��'......,.,.._ _.'zz;;�;;,. € �P 'y'v.fas>ria ` ,:J�'i<,��";,;� ,�rt�."'p't`�•``�:�";�,•�."� BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff ••BCIS Site Map Links t Search Product Approval (Zpr @USER:Public User Product Aooroval Menu>product or Aoolication Search>Application List>Application Detail f' i v •'.'- FL# FL22300-R1 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Northeast Building Products Inc. Address/Phone/Email 4280 Aramingo Ave Philadelphia,PA 19124 (215)535-7110 L.Knowles@nbpmail.com Authorized Signature Lucas Turner Luke@TurnerEC.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Double Hung Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Scott Wolters,PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E 1886 2005 ASTM E 1996 2009 TAS 201/202/203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 12/28/2017 Date Validated 01/07/2018 https://www.floridabuilding.org/pr/pr_app_dd.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPIxi6IKILNaUwjFbYC3vEIF7geadJ3C6vg%p3d%3d 1/2 J 1/16/2018 Florida Building Code Online Date Pending FBC Approval Date Approved 01/10/2018 Summary of Products FL# Model,Number or Name Description ................. _..._ _..........----._.._..__.........._....... ........._...._......__.... � _._..._.._._.._ .._ _�_�... 122300.1 u _ WinForce Double Hung Impact WinForce PVC Double Hung Window,Large Missile Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22300 Rl C CAC 86-157CAR.odf Approved for use outside HVHZ:Yes FL22300 R1_C CAC 86-164CAR.odf Impact Resistant:Yes FL22300 R1 C CAC 86-204CAR.odf Design Pressure:N/A FL22300 R1 C GAG 86-211CAR.odf Other:Please see Certifications,Installation Instructions,and FL223nn R1 C CAC 86-214CAR.Ddf Evaluation Report for additional information,design pressures, FL22300 Rl C CAC 86-215CAR.odf and configurations that are approved for the HVHZ. FL22300 R1 C CAC86 16 AR.odf FL22300 RI C CAC 86-403CAR.Ddf FL22300 R1 C CAC 86-412CAR.Odf FL22300 R1 C CAC 86-413 .AR.ndf FL22300 R1 C CAC 86-414CAR.12df FL22300 R1 C CAC 86-415CAR.odf F122300 R1 C CAC: 86-414 AR.pdf FL22300 R1 CCAC 86-424CAR.odf Quality Assurance Contract Expiration Date 02/16/2021 Installation Instructions FL22300 Rl II FPA-WinForce-DH-LM-A.odf Verified By: Lucas A.Turner PE#58201 Created by Independent Third Party:Yes Evaluation Reports i FL22300 RI AE EvalReport-WinForce-DH-LM-A.pdf Created by Independent Third Party:Yes 22300.2 WinForce Double Hung Non-Impact WinForce PVC Double Hung Window,Non-Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22300 Rl C CAC 86-156CAR.Odf Approved for use outside HVHZ:Yes FL22300 Rl C CAC 86-169CAR.12df Impact Resistant:No FL22300 R1 C CAC 86-404CAR.12df Design Pressure:N/A FL22300 RI C CAC 86-409CAR.odf Other:Please see Certifications,Installation Instructions,and FL22300 00 R1 C CAC 86-410 .AR.Ddf Evaluation Report for additional Information,design pressures, FL22300 Bl_ C CAC 86-411CAR.odf and configurations that are approved for the HVHZ. FL22300 R1 C CAC 86-417CAR.odf FL22300 R1 C CAC 86-4 AR.ndf FL22300 R1 CCAC 86-422CAR.odf Quality Assurance Contract Expiration Date' 02/16/2021 Installation Instructions F1 2231710 R1 II FPA-WinForce-DH-NI-A.odf Verified By: Lucas A.Turner PE#58201 Created by Independent Third Party:Yes Evaluation Reports FL22300 Rl AE Eva lReport-WinForce-DH-NI-A.odf Created by Inde endent Third Party:Yes 4iac4< Hk:xt Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.;;Privacy Statement;;Accessibility Statement:;Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here.. Product Approval Accepts: Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fKgXPIxi6IKILNaUwjFbYC3vEIF7geadJ3C6vg%3d%aid 2/2 GENERAL NOTES FL#223oo WINFORCE DOUBLE HUNG WINDOW 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMA/WDMA/CSA APPROVED CONFIGURATIONS NON-IMPACT 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA DESIGN BUILDING CODE,6TH EDITION(2017). CONFIGURATIONS NOTED AS HVHZ HVHZ IMPACT CONFIGURATION PRESSURE APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE APPROVED RATING ACCEPTABLE FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. RATING LOCK NOTE: 1 LOCK ASSEMBLY 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT 54"x77"EQUAL LITE YES +50/-50 PSF (ITEMS 23-25)ALLOWED FOR PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 24"x77"EQUAL LITE YES +50/-50 PSF 24"X77"MAX.SIZE ONLY. ALL 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING ARE AS 45"x86"EQUAL LITE YES +50/-50 PSF OTHER CONFIGURATIONS LIMITED BY ASTM E-1300 GLASS TABLES,AND TESTED WATER AND REQUIRE 2 LOCK ASSEMBLIES STRUCTURAL PRESSURES. 53"x86"EQUAL LINE NO +40/-50 PSF NONE 4.THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE Wl FULL SCREEN INSECT SCREEN NOTE: ALL THE INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE 53"x86"EQUAL LITE NO +50/-50 PSF SIZES EXCEPT 53"X86"MAY USE CONFIGURATIONS SHOWN IN THE ELEVATIONS. INSTALL PRODUCTS W/HALF SCREEN FULL SCREEN OR HALF SCREEN WITH MAXIMUM SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT, 42"X82"ORIEL NO +50/-50 PSF AT FULL DESIGN PRESSURE AND WITH FASTENER TYPE AS SHOWN IN THE DETAILS AND AS INDICATED IN TABLE 1. FOR FULL PRODUCT CONSTRUCTION DETAILS 54"MAX. SEE NCTL TEST REPORTS 210-4067-02/02At03/03A,AND WINDOW WIDTH 6"MAX 11"MAX'ON 24"MAX.WINDOW WIDTH 210-4083-03/04/05A/05C/06B/06C. 14"MAX.ON FROM CENTER, 5.MINIMUM GLAZING IS INSULATING GLASS 118 ANNEALED+1/2"GED CENTER,TYP. CORNER, NP' 6"MAX.FROM STAINLESS STEEL INTERCEPT SPACER+1/8"ANNEALED,GLAZED WITH J� .� �,P CORNER,TYP. GE SCS2801 SILICONE BACKBEDDING W/1/2"GLASS BITE. 6.THE 4/3 ALLOWABLE STRESS INCREASE FACTOR(SHORT-TERM INCREASE FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS FOR THIS SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF - �� O p ANCHORAGE INTO WOOD SUBSTRATE. a 00 a 04 p 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS) p?- ti. 0 M AND ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND U_t— tcy r u_ co Q 2 SHALL BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR W Lu AS APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). z Lucas � BUCKING,OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY O Z CyL- p z p_ Turner DESIGNED&INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO ;D U p I: ^p co U O ti O 2017-12-28 TRANSFER SUPERIMPOSED LOADS TO THE STRUCTURE. WITH 41I % � 01 t— � 16:26+19:00 MASONRY OPENINGS,WOOD BUCKS ARE OPTIONAL. w I w n 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE _ z r xx COATED OR OTHERWISE PROTECTED TO PREVENT GALVANIC uJ v W m Q REACTIONS. WOOD BUCKS,IF USED,SHALL BE PRESSURE TREATED, U m U ° ��oRsw r+,� WITH EITHER A TREATMENT OR COATING COMPATIBLE WITH THIS SILL ANCHOR 5 " SILL ANCHOR ..^`mow r raa 5820t ;� PRODUCT. SPACING SPACING = 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING SAME AS HEAD SAME AS HEAD COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL SrAle OF iw� OTHER WINDOW MATERIALS. 54„X77��EQUAL LITE ELEVATION 24��x77��EQ.LITE ELEV. '•,Fs� tiA �.`'U 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH THESE DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BY `'u»teasut'` FLORIDA REGISTERED PROFESSIONAL ENGINEER ON A SITE-SPECIFIC TABLE OF CONTENTS NORTHEAST BUILDING PRODUCTS �Z BASIS. SHEET DESCRIPTION 4280 Ararningo Ave.,Philadelphia,PA 19124 11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER 1 NOTES,ELEV., Ph.{215}535-7110 www.camelotwindows.cam 1 A.Tu Lucas A. ner INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE CONFIG.TABLE SHEET DESCRIPTION: DATE DRAWN: Luc # 82 5 P.E. RESPONSIBILITY OF OTHERS AND ARE NOT ADDRESSED BY THIS 2 ELEV.,GLAZING NOTES,ELEVATION 4/13/2017 FL PE DOCUMENT. 3 VERTICAL SECT. 1239 Jabara Ave.A SCALE: NTS REV:A North Port FL 34288 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 4 HORIZ.SECTIONS SHEET 4. 5 BOM,PART DWGS DRAWING:FPA-WINFORCE-DH-NI SHEET. 1 OF 5 1 Ph.941-380-1574 WINFORCE DOUBLE HUNG WINDOW, NON-IMPACT 45"MAX. 53"MAX. WINDOW WINDOW 42"MAX I I"MAX. WIDTH 6"MAX. 12"MAX. WIDTH 6"MAX. WINDOW ON CENTER,-j FROM ON CENTER, FROM 14"MAX. WIDTH 6"hM. TYP. CORNER, TYP. CORNER, ON CENTER, FROM —I TYP. TYP. TYP. CORNER, 0 0 0 0 0 -0 0 0 0 0 TYP. f 0 0 0 0 0 � a axxo ten: No 0 0 0 CO 0 LL cr) 21! LU m w LL 0 z z LLI 0 0 Z EL Lu z m 0 Z (L LLI 0: Z LU CO 0 0 0 b L) <> 0 L11 Co C) w Ey N 0 '.I " LU M F-- Co 0 CD CI <— z 0 z .IE1--z 0 Z C) LLI -i w -j LLI 0 C) co m (3) SILL ANCHOR SILL ANCHOR SILL ANCHOR SPACING SPACING 4- 1 1 SPACING SAME AS HEAD 0 0 0 0 SAME AS HEAD () Q Q Q 0 SAME AS HEAD 45"x86" EQUAL LITE ELEVATION 53"x86"EQUAL LITE ELEVATION 42"X82"ORIEL ELEVATION SEE TYPICAL 1/2"GED 1/8"ANNEALED GLAZING 20 22 SEE LOCK STAINLESS STEEL GLASS NOTE, DETAIL INTERCEPT SPACER SHEET GE SCS2801 No SS201 1/8"ANNEALED SILICONE 16 D - GLASS srATE OF `ft 17 z- . ........ .k. 36 34 17 0 NORTHEAST BUILDING PRODUCTS 4280 Aramingo Ave.,Philadelphia,PA 19124 -57 EXT. Ph.(215)535-7110 www.camelotWmdows.com . L 8 9 1 12(27/2017 EXT. INT. 25-2 SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. ca N! ELEVATIONS,GLAZING DETAIL 4/13/2017 FL PE#58201 MEETING RAILS DETAIL TYPICAL GLAZING — 1239 Jabara Ave. DETAIL SCALE: NTS REV:A North Port,FL 34288 DRAWING:FPA-WINF0RCE-DH-NI SHEET. 2 OF 5 Ph.941-380-1574 WINFORCE DOUBLE HUNG WINDOW, NON-IMPACT SEE GENERAL ANCHOR NOTES,SHEET4. MIN.EDGE DIST., SEE TYP.GLAZING DETAIL SHEET 2 9 APPLIES TO BOTH SUBSTRATE EXT.AND INT.SIDES, z w w_ 4 BY OTHERS, m w m SEE TABLE 1 SEE TABLE 1 ;E U)Q 15 w F- EXT. INT. CLEARANCE SEALANT BY 36 HOLE AND PLUG INSTALLER 10 D O- INSTALLATION FASTENER,SEE 1 1 TABLE 1, v SEE � ❑ LOCATIONS ���wU 15 �axQ 00 SHEETS 1-2 Baia g m o SEALANT BY ID 8 O rn INSTALLER 0 35 STRUCTURAL SILICONE DINSTALLATION - FASTENER,SEE MIN.EDGE DIST., o w SUBSTRATE TABLE 1,SEE z_w w_j APPLIES TO BOTH EXT. INT. m w m BY OTHERS, LOCATIONS w m SEE TABLE 1 EXT.AND INT.SIDES, SHEETS 1-2 SEE TABLE 1 SEE TYP.GLAZING DETAIL SHEET 2 CLEARANCE HOLE AND PLUG TYPICAL HEAD VERTICAL SECTION TYPICAL SILL VERTICAL SECTION T.' TABLE 1:EQUAL LEG/FLANGE FRAME INSTALLATION ANCHOR REQUIREMENTS TABLE `4i NOTE: ALL ANCHORS ARE PAN HEAD OR HEX WASHER HEADS i srars oc i SUBSTRATE TYPE - ANCHOR TYPE MIN.EMBED. MIN.EDGEDIST. Fs <,o...... CONCRETE(2.0 KSI MIN) 3/16"ITW TAPCON 1" 1 1/8" ' NORTHEAST BUILDING PRODUCTS MM HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" 4280 Aramingo Ave.,Philadelphia,PA 19124 `Z CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" Ph.(215)535-7110 www.camelotwindows.com 12/27/2017 2X MIN.SOUTHERN PINE WOOD(G=0.55) #10 GRADE 5 WOOD SCREW 1-3/8" 1" SHEET DESCRIPTION: DATE DRAWN: Lucas A.Turner,P.E. HEAD/SILL INSTALLATION 4/1 312 0 1 7 FL PE#58201 16 GAUGE(0.060")MIN.STEEL STUD,33KSI #10-16 HILTI KWIK-FLEX OR ITW 1/2" 1239 Jabara Ave. YIELD MIN.,OR 1/8"ALUM.6063-T5 MIN. TEKS SELF-DRILLING SCREW FULL SCALE: NTS REV:A North Port,FL 34288 DRAWING:FPA-WINFORCE-DH-NI SHEET. 3 OF 5 Ph.941-380-1574 WINFORCE DOUBLE HUNG WINDOW, NON-IMPACT 1/4"MAX. 1/4"MAX. INSTALLATION FASTENER, SHIM SPACE _INSTALLATION FASTENER, SHIM SPACE SEE TABLE 1,SEE SEE TABLE 1,SEE LOCATIONS SHEETS 1-2 MIN.EMBED., LOCATIONS SHEETS 1-2 MIN.EMBED., SEE TABLE 1 SEE TABLE 1 CLEARANCE CO CLEARANCE w=z w r HOLE AND PLUG a zui r HOLE AND PLUG aE- _cn p w ❑ ap w wQmxsc6m wQ °o °dm00 INT. Z :'0 — Uj ° INT. z -p w ° � U~ LUfq ~ oo � �_~ w (A ~ ao 0 � n a SEE TYPICAL o a GLAZING DETAIL,El o SHEET 2 0 SUBSTRATE EXT. SUBSTRATE EXT. BY OTHERS, BY OTHERS, 5 SEALANT BY SEE TABLE 1 SEE TABLE 1 INSTALLER SEALANT BY 3 18 9 37 INSTALLER TYPICAL JAMB HORIZONTAL SECTION TYPICAL OPTIONAL ADD-ON FLANGE SECTION, - JAMB SHOWN, MAY ALSO BE USED HEAD/SILL GENERAL ANCHOR NOTES: :GrS cxusfi�R�..� 1.INSTALL ONE ANCHOR AS INDICATED IN DETAILS ON SHEETS 3 AND 4 AT EACH LOCATION SHOWN IN THE ELEVATIONS ON SHEETS 1 AND 2. =*: 2.INSTALL SHIMS AT EACH ANCHOR LOCATION WHERE A GAP OF 1/16"OR GREATER EXISTS BETWEEN PRODUCT FRAME AND SUBSTRATE. 3.SHIMS SHALL BE LOAD-BEARING(PLASTIC OR METALLIC)AND CAPABLE OF '.,�3S,�hA1 Eta��`• TRANSFERRING LOADS TO SUBSTRATE. NORTHEAST BUILDING PRODUCTS 4.SPECIFIED ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL FINISH OR ZZ STUCCO,BY OTHERS. FOR ATTACHMENT TO METAL SUBSTRATES ENSURE FULL THREAD 4280 Aramingo Ave.,Philadelphia,PA 19124 ENGAGEMENT THROUGH METAL WALL WITH MIN.3 THREADS BEYOND. Ph.(215)535-7110 www.camelotwindows.com 1 212 7/2 01 7 5.FOR MASONRY WITH WOOD BUCKS LESS THAN 1-1/2"THICK,EMBEDMENT SHALL BE SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. BEYOND WOOD BUCKS AND INTO MASONRY. WOOD BUCKS ARE OPTIONAL WITH MASONRY JAMB INSTALLATION/ALT.FLANGE 4/1 312 0 1 7 FL PE#58201 INSTALLATIONS WHERE MASONRY EDGE DISTANCE CONDITIONS ARE MET WITH NO BUCKS. 1239 Jabara Ave. WOOD BUCKS 1-1/2"THICK OR GREATER SHALL HAVE EMBEDMENT INTO THE WOOD BUCKS. SCALE: NTS REV:A North Port,FL 34288 6. ENSURE 3"MIN.ON-CENTER SPACING BETWEEN ANY TWO INSTALLATION ANCHORS. DRAWING:FPA-WINFORCE-DH-NI SHEET. 4 OF 5 Ph.941-380-1574 BILL OF MATERIALS WINFORCE DOUBLE HUNG WINDOW, ITEM DESCRIPTION PART NO. SOURCE MATERIAL NON-IMPACT 1 HEAD 10005160 DECEUNINCK PVC 2 SILL 10005161 DECEUNINCK PVC 432'�I 15 3 JAMB 10005162 DECEUNINCK PVC ❑ ❑ 432 4 SILL EXTENSION 10001 DECEUNINCK PVC �� O 5 ADD-ON FLANGE 10008348341 DECEUNINCK PVC 6 SASH STOP 10008483 DECEUNINCK PVC r;la 7 N �O O r'M 8 WEATHER STRIPPING .187 BK X.220 HT ULTRA FAB FIN PILE U w 9 WEATHER STRIPPING .187 BK X.290 HT ULTRA FAB FIN PILE 10 WEATHER SEAL-SILL FOAM FILLED BULB AMESBURY FOAM/POLYETH. O ❑ ❑ 11 BALANCE CLIP ROLLER TILT-RT562 CALDWELL O 12 FRAME SCREWS-SILL TO JAMB #8 X 1/2"PPH-SS MERCHANTS ST.STEEL 13 BALANCE SCREWS #8X7/8"PFH -SS MERCHANTS ST.STEEL 14 �` 232' 15 TOP/BOT.LIFT RAIL 10005541 DECEUNINCK PVC 16 KEEPER RAIL 10005543 DECEUNINCK PVC 17 LOCK RAIL 10006542 DECEUNINCK PVC --{ 1 32' 12" 18 TOP/BOT.STILE 10005540 DECEUNINCK PVC JJ_ 19 BULB SEAL 10008206 DECEUNINCK PVC 20 GLA7JNG BEAD-3/4"IG NON-IMP. 10005456 DECEUNINCK PVC NIA SIN u 21 PIVOT BAR 16Y513 STAINLESS STEEL CALDWELL ST.STEEL ❑ n 22 PIVOT BAR SCREW #6 x 5/8"PPH TEK-SS MERCHANTS ST.STEEL D� �CQ 23 LOCK D2100AL-XX ASHLAND TIN-ZINC 35 36 15 24 LOCK SCREW #8 X 1"PAINTED PFH MERCHANTS STEEL 25 IKEEPER 13999-999-XX ASHLAND TIN-ZINC ❑ 26 KEEPER SCREW #6 X 3/4"PAINTED PFH MERCHANTS STEEL 27 VENTSTOP 1760 VISION VINYL O 28 TILT LATCH-UPPER SASH 7397 FC-R/7397 FC-L VISION VINYL 29 TILT LATCH-LOWER SASH 2OF0041 LH /20F0042 RH CALDWELL VINYL 1" 30 TILT LATCH SCREW-LOWER SASH #8 X 3/8"PPH TEK MERCHANTS STEEL 120� 11" 31 TILT LATCH THUMB BUTTON 20F000501/502 CALDWELL VINYL T 16 32 CENTER FIN WEATI ERSTRIPPING .270 BK.x.270 HT.Adhesive ULTRA FAB FIN PILE T 34 LOCK RAIL REINFORCEMENT 10300266 ASTRO SHAPES 6005-T5 ALUM. -AC'I �p•�`�PtSDRE4Y�T 35 TOP LIFT RAIL REINFORCEMENT 10300159 ASTRO SHAPES 6005-T5 ALUM. �T� � `;-Lies cy% 36 KEEPER/BOTTOM LIFT RAIL REINF. 10300159 ASTRO SHAPES 6005-T5 ALUM. 37 STILE REINFORCEMENT 10300166 ASTRO SHAPES 6005-T5 ALUM. �9: S'rrsTE s3F :Sri. N 132" 123" ......... O 32 NORTHEAST BUILDING PRODUCTS l _ ❑ 4280 Aramingc Ave.,Philadelphia,PA 19124 u� _IN rile Ph.(215)535 7110 www.camelotwindows.com 12/27/2017 23" SIN Nc� Lucas A.Tumer,P.E. 32 ❑ SHEET DESCRIPTION: DATE DRAWN: O 17 �� 34 BILL OF MATERIALS,PART DWGS 4/13/2017 FL PE#58201 SCALE: NTS REV:A 1239 Jabara Ave. 16 North Port,FL 34288 DRAWING:FPA-WINFORCE-DH-NI SHEET. 5OF5 Ph.941-380-1574