Loading...
HomeMy WebLinkAbout19-20889 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20889 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20889 Issued: 2/27/2019 Address: 39631 DAWSON CHASE DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 18,396.47 Subdivision: HIDDEN RIVER Amount Paid: 18,396.47 Date Paid: 2/28/2019 Parcel Number: 24-26-21-0100-00000-0140 CONTRACTOR INFORMATION OWNER INFORMATION - Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc:, CONSTRUCT SINGLE FAMILY 2,276 SQ FT APPLICATION FEES BUILDING FEE 1,426.49 ELECTRICAL FEE- 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 7,728.00 SCHOOL IMPACT FEE-sfr/1% 77.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 4_ Ins 'ecti Required FOOTER 2 D ROUGH PLUMB Misc INSULATION CEILING_ FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance' with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. NTRA TOR SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills permit Application pm+813-7e0-0021 ' ^ Building Department Date Received uwnxooxo umn � m ownoeumamw Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 ress FL 33607 Owner Phone Number / Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LoT# ouBoxxS|Om Hidden River Phase One B PAmosL|m* 24-26-21-0100-00000-0140 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED wcwcoworx F7 Aoo6A[T F--� SIGN �—� �—� DEMOLISH P INSTALL [_] REPAIR PROPOSED USE aFR [—� Comm [---� o7*En TYPE orCONSTRUCTION auocK F—1 pR�m� F--� aT�s� F—1 DESCRIPTION opWORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING Sxcs U/R SF SQ FOOTAGE y=��/ ] HEIGHT i Story � �� uU|Lo|NG ��-] VALUATION Or TOTAL CONSTRUCTION FLecT8|CAL ^ —1�� peo�nsa��wsR�r [—� vv.R.E.c. AMP SERVICE � �-� PLUMBING �MECHANICAL VALUATION OF MECHANICAL INSTALLATION F--lGAa ROOFING F—1 SPECIALTY [--� OTHER J--� �—I FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA U �YE8 | NO ���^ ��� ` BUILDER COMPANY I I SIGNATURE F REGISTERED Y/ N FEE CURREN Address License ELECTRICIAN COMPANY Edmonson Electric, Inc. Address 11034 Skipper Road,Ttmpa, FL PLUMBER COMPANY t Plumbing, Heating &AC, MEcn/wmcxL COMPANY [��ayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED �� L�4_N_] pssounnsx L���_� Address License# cnnEn COMPANY C Sterling Quality Roofing, Inc SIGNATURE pssounns^ Address Ummoa# � . xmxxxxxxwxxumxxouxxwxxumxxmxxxmxxmxnnmxxuuxnmxxuxxxwxxumxnmxxxmxxun . RESIDENTIAL Attach pV Plot Plans;Cg sets of Building plano;(1}wetm[EnnrgyFonna;R'O4VPonnKhxnewuonotruuion. Minimum ten(1O)working days after submittal data. Required onsite,Construction Plans,Stormwater Plans w/sift Fence installed, Sanitary Facilities m1dumpotecSite Work Permit for subdivisions/large projects cO0MsRnUw' Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1u)working days after submittal date. Required onsite,Construction Plans,-Stormwater Plans w/Silt Fence installed, Sanitary Facilities u1dumpvmc Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Fill out application completely. Owner&Contractor sign back of application,notarized n over$oenu.a Notice c«Commencement Is required. VVo upgrades over$r5om °^ Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy uf contract required) ` nommfs if shingles Sewers Service Upgrades AK: Fenxeo(P|oVavrvay/routa8a) Driveways-Not over Counter ifun public mouwmya..nendvROW -_- ' NOTICE OF DEED RESTRICTIONS: The undersigned underotandnthsdthispennitrestrictions" Which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by |ew, both the owner and contractor may be cited fora misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at727-847- 8OOQ. Furthennona, if the owner has hired e contractor or oontnsctoro, he is advised to have the contnaoior(a) aign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign am the oontnactor, that may be on indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IKHPAClRN'MLVT|ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing bui|dingo, as specified in Pasco County Ordinance number 89-07 and 90'07. as amended. The undersigned also understands, that such hseu, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" or final power release. |f the project does not involve m certificate nf occupancy nr final power re|eaae, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713. Florida Statutes, aommnendmd): |f valuation of work io $2.5UD.00or more, | certify that |, the opp|icmnt, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. |f the applicant insomeone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver ithz the"mwner"prior tocommencement. C[)NTR\CTOR'88OWNER'SAFF|DAV|T: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating oonotruotion, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. \ certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all |mwn regulating conntmunbon. County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government eganoiao may apply to the intended work, and that it is my responsibility identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department cfEnvironmental Protection-Cypress Boyheadu, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management Diothot4AAeUn. Cypress Bayheedo' VVat|ond Aneoo, Altering VVotorcounoee. - Army Corps nf-Engineane-Ga*wvoUm. Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVaUu, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authority Runwa | understand that the following restrictions apply to the use offill: ' Use of fill io not allowed |n Flood-Zone Wp unless expressly permitted. ' If the fill material is to be used in Flood Zone "A., it is understood that o drainage | addressing a "compensating volume" will be submitted at time of permitting which is prepared by a pnnhaaoiona| engineer licensed by the State ofF|or|do. ' If the fill rnataho| is to be used in Flood Zone "A" in connection with a permitted building using stem vvoU construction, I certify that fill will be used only to fill the area within the stem wall. ' If fill mohe,io| is to be used in any area. | certify that use of such @| will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent ppopartiem, the owner may be cited for violating the conditions of the building permit issued under the attached pann|t application, for lots |eoe than one (1) acre which are elevated by fill, on engineered drainage plan |orequired. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that separate permit may be required for electrical work, p|umb|ng, eigna, vveUo, poo|a, air uonditioning, gas, or other installations not npeoUiomUy included in the application. A ` permit issued shall b d to be license to proceed with the vvorkand not as authority to vio|ate, oanoa\, a}ter, or set aside any provisions ufthe technical codes, nor shall issuance ofa permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid un|aou the work authorized by such permit is commenced within nix months of permit issuance, or if work authorized by the permit io suspended or abandoned for a periodof six(G) months after the time the work iocommenced. An extension may be naqueoted, in writing, from the Building Official for o period not to exceed ninety (QO) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TORECORD A NOTICE OF COMMENCEMENT MAY RESULT lNYOUR PAYINGO IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN A�IORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR - Subscribed u Subscribed - - IV VqFo-is/are personally known to m r#asA4ave­pFedyGed Who is/are onallv kr own to me or hasihave pfedue as identification. Notary Public Notary Public Commission NO. ,,""^'' �- ovmm/o���o ,,""^3' ElisoaM.BoDozuo ElisouM.HoDeruo Name of Notary twed.Printed or stamned Name of Notary typed,printed or stamped D .` Single Family Dwelling Plan Review Comments 1. F.F.E.shall be a minimum of 8" above the road elevation and an engineered site plan. 2: .Lots shall be graded to cori- ly with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. .Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk.shall have expansion material.. 6. All setbacks shall be:'et. 7. All propertv.markers shall be uncovered and marked at time:of first inspection. 8: All A:D.A."requirements shall be met. 9. 'No electric, plumbing,. mechanical, or framing shall.be covered without an inspection.and approval first. l06 Alt Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11.Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M3014 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for AX-units.shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308:4-of the F.B.C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum,board" shall riot be used as a backer in showers or tubs. R702.4.2 F B.C. 19: Com'binatiori-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all un,dergrbund plumbing and electric. 21 All 2016 NME.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure. 25. Blower door test shall be provided before C,O. 26.A cony of the energy caelsshall be with permit at all.tifnes. 27 Copy of final insulation report-shall'be provided with Permit before rinaL 28. Na knee,pool or screen enclosure is issued with this permit F.F.E.-Finished Floor Elevation F.B.C= Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) T FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0014 Street: 39631 Dawson Chase Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: j��Q Owner: Lennar Homes Jurisdiction: 611600 / Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.33 87.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.248 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and 'CS$T,;` this calculation are in compliance with the Florida Energy specifications covered by this p•. Code. calculation indicates compliance with the Florida Energy Code. �-+' rirji ,: �' ;:•�.. „ O PREPARED BY: Lave Aupich Before construction is completed ,M DATE: this building will be inspected for compliance with Section 553.908 ;= I hereby certify that this building,as designed, is in compliance Florida Statutes. fif: with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL DATE: DATE: - Compliance requires certification by the handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0014 Street: 39631 Dawson Chase Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Duct s R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.33 87.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.248 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and ?,gr.. this calculation are in compliance with the Florida Energy specifications covered by this � _- p••_ `. Code. calculation indicates compliance with the Florida Energy Code. F+:' /i�ii ••; n O PREPARED BY: Dave Aupich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. �D::yyj: ,. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0014 Street: 39631 Dawson Chase Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes .jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftz b.Frame-Wood,Adjacent R=11.0 331.33 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Duct c. R= ft2 s R ft2 7. Windows(143.3 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.33 87.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.248 14.Hot water systems 8. Floor Types (1817.0 sgft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and 'Ck .ST.q` �. 21, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: �QVe ACdgch Before construction is completed DATE: this building will be inspected for �a�r compliance with Section 553.908 < I hereby certify that this building,as designed, is in compliance Florida Statutes. > with the Florida Energy Code. Ojj:y1 . OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 , INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1791A1 sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: 3540 vinyl windows CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InflID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood t 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w# Ornt To Wall Type R-Value Ft In Pt In Area R-Vallle Fraction Absor CrqrJP% 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0.23 0.01 0 _ 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0.23 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms. U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS - Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 'N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 2 E=>SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Vinyl Law-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION J # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2649 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 , INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed On Main —cfm 54.5 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma X Jun [X]Jul rj Au jXj Se Oct Nov Dec Heatin Jan Feb Xj Mar Apr I i May r l Jun E ]Jul Aug Sep Oct Nov Dec Oct Nov Dec Venting Jan Feb X Mar Jun ]Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 .78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 -66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 i 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 28.4 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1817 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.388 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.248 14. Heating system: Capacity 28.2 c)Area 7c. 143.3 a)Split system heat pump HSPF b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 15.Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(Insulation R-value) 10B1. 11.0 2. Masonry(Insulation R-value) 1062. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c)Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11 d. No e)Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise, a new EPL display card will be completed based on installed code c pliant features. Builder Signature: Date: 01/23/19 Address of New Home: 3963 awson Chase Drive City/FL Zip:_ , FL Zephyrhills,FL 33540 1/8/2019 6:53:36 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Analysis Job: 1791A1sf ADS CarrierVW g Y Date: 11/28/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh % of load Walls 5.2 7664 29.6 Ducts Glazing 21.6 3908 15.1 wall Infiltration Doors 23.5 466 1.8 Ceilings 1.3 2271 8.8 Floors 3.4 6125 23.6 Infiltration 1.7 2882 11.1 Ducts 2616 10.1 Piping 0 0 Floors Humidification 0 0 Glazng Ventilation 0 0 Omer Ceilings Adjustments 0 Total 25932 100.0 • • Component Btuh/ftZ Btuh % of load Walls 2.8 4096 18.3 Glazing 40.6 7352 32.9 Wall Internal Gains Doors 18.4 365 1.6 Ceilings 1.7 3140 14.1 Floors 0 0 0 Infiltration 0.4 645 2.9 Ducts Ducts 2982 13.4 Ventilation 0 0 Internal gains 3750 16.8 Infiltration Blower 0 0 Glazing Adjustments 0 Ceilings Total 22330 100.0 other Latent Cooling Load= 2873 Btuh Overall U-value= 0.098 Btuh/ftZ-°F Data entries checked. -Fk- wriightsoft- 2018-Nov-28 15:56:05 ^�*•���=^w�- Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCN ..ment%1791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: S Project Summary Job: 1791A1 sf ADS CarrierVW, 1 ry Date: 11/2812018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: vinyl windows Desian Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23316 Btuh Structure 19348 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfrri) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25932 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22330 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2339 Btuh Ducts 534 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cdolingg (none) Area(ft2) 1817 1817 Equipment latent load 2873 Btuh Volume(ft') 15431 15431 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 25203 Btuh Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC53OA00300 Cond 25HBC53OA00300 AHRI ref 9154945 Coil FX4DNF031L AHRI ref 9154945 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24140 Btuh Heating output 28200 Btuh @ 47°F Latent cooling 4260 Btuh Temperature rise 26 OF Total cooling 28400 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 30 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4k— 2018-Nov-28 15:56:05 ^�^•� - ^• Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ment\1791 sf ADS template VW 2.5ton Carrierrup Calc=MJ8 Front Door faces: S Job: 1791A1 sf ADS Carrier VW Manual S Compliance Report Date: 11/28/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling-Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 22330 Btuh Entering coil DB: 75XF Outdoor design WB: 77.3°F Latent gain: 2873 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 25203 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Sensible capacity: 24140 Btuh 108% of load Latent capacity: 4260 Btuh 148% of load Total capacity: 28400 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 25932 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Output capacity: 22528 Btuh 87% of load Capacity balance: 30 °F Supplemental heat required: 3404 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. t wrightsoft` 2018-Nov-28 15:56:05 •�.���w� ,�w, Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCK ..ment11791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: S r i PASCO COUNTY, FLORIDA I Permit No. ��// Date Permitted2—z7-1. Builder Name/Owner Name A"CA Control#' County Parcel No. `f-Z -Z(.(�l 0�b 0(�D-(�� � SubDiv: 14f0(dfA Address/Location 3 Classiflcatlonrrype of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z76 Exempt ❑Yes [:] No How Determined Impact Fee Amount $. 6 3�, tfb Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7606, 2,6 (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt � Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ _7(erg. 66 Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt ❑ Yes [] No How Determined Total Amount - RESOURCE FEE , ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes 39631 Dawson Chase Dr.2,276 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 40.00 BUILDING: $ 1,421.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,057.50 Public Fee 1% TOTAL $ 2,057.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,184.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,391.47 —____— XmaTn# �NY�N����� en �O�� ps ��1� &��������& ���� 6u�w 02/25/201.9 02:36pm Page I of I ' . Rcp«: 2031348 nec: 10.00 oa: 0.00 IT: 0.00 Paula S. O'Neil ' Ph.D. ' Pasco County Clerk & Comptroller Permit No. Parcel mNo 24-26-21-0100-00000-0140 NOTICE OF COMMENCEMENT state of Florida County of Pasco THE UNDERSIGNED hereby gives notice that Improvement will Ue made h/certain real property,and in accordance with Chapter 713.Florida Statutes, the following information is provided in this Notice m[Commencement: I. Description v,Property: uvge| eo �� Adumoo: 39631 Dawson Chase Drive Zephryhills FL 53541 / / c. monrm|ooaonpVvnvv|mpmvnmom Single Family Pooi/8cn�o Enclosure Fence LennmrHomea LLC o. Owner Information: . Name Address city State Interest InProperty: Name m Fee Simple Titleholder* N/A (if other than owner) Address city State 4. Contractor: Lennar Homes, LI-C Name Address city State Contractor's Telephone No.: 813.574.5700 *. Surety: Name Auunao city State Amount ovBond: Telephone No.: o. Lender: / Name Address City State Lender's Telephone wv.: 7. Persons within the State of Florida designated by the owner upon whom uo8mao or Nhn, documents may be served as provided by Section/1»'1»(1)V$6D.Florida Statutes: Name Address city State Telephone Number of Designated Person: 813.574.5700 m� � In addition mh�n��mevwn�d��n�e to receive ocopy of the Llenor's Notice as provided m Section nm�)(b),Florida Statutes. Telephone Number of Person m Entity Designated byOwner: 0. Expiration date of Notice of Commencement Is one year from the date of recording unless a different date is specified: WARNING NOTICE OF C MMEmCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE oFFLORIDA COUNTY Opp|wELL\G Signature m Owner or Owner's Authorized mnoexu/motunrartnevMmnogr, Vice President ' mignamry'oTmexOffico ' 23 m[ January »y Steve Robert Smith fa, for Lennar Homes, LI-C (name of p y on of whom instrument was executed). Personally Known N OR Produced Identification El Notary Sig ' Type v*memm000unpmuu*au ' Name(pm� ��//��� / /v//�/o// Verificatioo pursuant0u Section 9l625.Florida Statutes. Under penalties of perjury,|declare that\have read the-foregoing and that the facts stated in it are true m the best nfmy knowledge and belief. ' Signature m Natural Person Signing Auvvo` Expires June 0,2020 vpuutamcs1bo form., ' — STATE OF FLORIDA,COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGO11"G IS A TRUE AND CORRECT COPY OF THE DOCUMENT. o✓� ON FILE OR OF PUBLIC RECORD IN THIS OFFICE .' WITNESS MY HAND OICIAL SEAL_THlIS ��7ES DAYOF � 2PA L IS0' � �, °" In�°d�e�r�t • L CLERK&C0MPTROOLL R ~ � o � BY DEPUTY CLERK g887� i,\•�'4 �'�t 4' :Y•M ..l.rM• «Yl•. .,� •N. .a f.�,• ,•I,Y -:.i.._.....,. ..r•., '._.n t ..T„. ...«.•e.. ''_Ya' .•—e.a_ •.—._ .••.K • ,aa ,Yre,. a . .•a» ....n,.v -•,rr� ..M1•—na -. »,♦ ...` i•`• v a—n ,. '.)N r . u .l ,t,r ."• Yam} �y1 .�.�;�yy+�• �k � . . :. J Y!' .r.j.y..♦•r...._�i.a ...a. �4� •i•r •! . • �r ,IWYIIir' �,Y�Ar '11 •�`,•:�.,�-.• i+ ..», —,' k � • .r. .'♦Y.�. .a...'�.•a��•W Wi'Ynwr' f .• .. - .,' /' �• {}{'rl •• �r J,....••.` ._•l.. ak .. a. •..• f• F '• .. t . -�r�•••••- I I I I 1 i I l l i i I I # _ I ,►� - 2I—A0M a m-.. 4$ 18A �- I ! fir'�' ! i t �- I ! FF fit. ,! ! �F !. ! FF E� # ! FF©. i I ! Fi. E i $. ��V 13- .CFO I I 7 ? Tawl 1 ?'ATM # -"� # ! lT• # 1 7 E E ...•—. .. ............ ............ .. ,....• .•... ._..w ......Y.a..:. •_...........•s•.•a.a........ ..»• eJr, q xw :.r.Mv..r, •• ♦aa...• .,•_..vwe.,»..a.•....�..,._...«....._.. rY -. • •—•_. Y . ... I --........ ..........a....... Na•a ' • , fY /} ..... + � �1 -DRIVE""' N._.._,.. ..•_---� . .• '• ... . .S.L•. 1.•, • 1... 1 .YL.n1._•.»_...._....._._... •• - F e. k I eel Jh &FE a. i 1 ! F El. 1 I i I �► I ti i 3 '� I , A , :,� : 317 313 1131 9 3 0•f W .•_...1..n•..�..—,.•..,+s�.�.IIIr Yam. lb .vw TIM 92 .,,r��• +rf+�. .�•war i��!��,+++}I�waf+wxw. " � l I ` i � � �• l_� � I - � � l SKETCH ONLY SEC. 24 TWP. 26 S. RNG. 21 E. PLAT PLAN NOT A BOUNDARY SURVEY LOT 14 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY j ALL DIMENSIONS BEFORE ANY CONSTRUCTION. UNDERGROUND FOOTER, STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: SHOWN. --AA,— = PROPOSED DRAINAGE FLOW 11 DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE o NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: a PAGE INDICATES THAT PLAT IS IN LOT GRADING TYPE = A vvi PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION = N/A CHANGE AND/OR REVISION. FRONT SET BACK = 20' CERTAIN DATA SHOWN HEREON BASED ON SIDE SET BACK = 10' ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 10' STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. THE EMERALD POINTE TRACT "H" RV RESORT PHASE THREE . = 10 DRAINAGE UTILITY EASEMENT LANDSCAPE & (FIAT BOOK 3B, PAGES 7-11) '�; - / - 5' DRAINAGE EASEMENT BUFER EASEMENT HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) S 89'40'43" E 60,00' r�s ----- 1� osJ i - PLAT BOUNDARY ON LOT AREA CALCULATIONS t :ci LOT 14 o i - n LOT = 6600.00 S0. FT. LIVING AREA 1838 SQ. FT. I I ENTRY = 32 Q. FT. I I GARAGE 406 Q. FT. I atn A/C 0 I COVERED LANAI =_ / SQ. FT. �0.00 10.00, PATIO = 23 SQ. FT. I I o I I 0 CONC. DRIVE = 339 SQ. FT. o I .0-,Or i O A/C & CONC PAD = 9 Q. FT. I I o PRIVATE SIDEWALK = 72 SQ. FT. I I IMPERVIOUS = 41 _% PROPOSED I * = 2719 Q. FT. w * PLAN * SOD _ 3801 _SQ. FT. LOT 15 * 1791 i ELEV "Al" v LOT 13 DFF LOT AREA CALCULATIONS GARAGE v°i I RIGHT OF WAY = 720.00 SQ. FT. I LEFT I DRIVE APRON =--14-4 —SQ. FT. b 1000' ( PUBLIC SIDEWALK = 240 Q. FT. o •-••I•••• I a SOD =�336 Q. FT. Z 11 I V) TOTALS AREA = 7320.00 Q. FT. I. 10.00, DRIVEWAY =_ 483 SQ. FT. 16.00p j... SIDEWALK =_ 312 -SQ. FT. I n " , ° ( SOD _ 4217 SQ. FT. R i •p Y * a0 6.00. L " N 89'4043 W 60.00 :6.15 BOUNDARY o: 20.00 PRM(P) N .N DAWSON� CHASE DRIVE HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) (50'R/W) PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 75.80' DESCRIPTION: GARAGE AREA: 75.26' LOT 14, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", ELEVATIONS REFERENCED TO AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, NATIONAL GEODETIC VERTICAL OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. DATUM OF 1929. MEAN SEA LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 Project Number. Square Feet: 6600.00 t LENNAR HOMES LEGEND: {C}= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE-OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&0= FOUND�NAt'DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.- MASONRY, OR- OFFICIAL RECORD BOOK, PB- PLAT BOOK, PCP- PERMANENT-CON'ROL:POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAZI.+&,�3+sk; _TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE F= WOOD FENCE JOHN R.BEACH&ASSOCIATES,INC. Drawn By: -SMS - SURVEYORS AND MAPPERS 911 WEST ST. PETERSBURG DRIVE Checked By: ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 554-1276 FAX (813) 855-8370 Scale: ! NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 12/21 2018 RTM ' THE ORIGINAL RAISED SEAL 4F A FLORIDA GNA E LICENSED SURVEYOR AND MAPPER JOHN R, CH Revisions: FLORIDA'NW.CH LAND SURVEYOR,No. 2984 LB 4493 JEFF M. LEY L SURVEYOR & MAPPER No.7123 CITY OF / / / / BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION-� OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT# :5q&; ( ?�0e)F) THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. IV ar It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780_0020 F R1 E-INS TION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR Jacqueline Boges From: City of Zephyrhills Support <support@zephyrhillsfl.zendesk.com> Sent: Monday, March 4, 2019 11:36 AM To: Jacqueline Boges Subject: [Request received] 39631 dawson chase dr by#20889 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/265466 ............................................................................. .................... ............................... ....................................................................................................................................................................................................... Jacqueline Boges `- - Mar 4, 9:35 AM MST service 39631 dawson chase dr by#20889 This email is a service from City of Zephyrhills Support . 1