HomeMy WebLinkAbout19-21411 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 21411
BUILDING PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 21411 Address: MIS SEE DESCRIPTION 5935 7TH ST
Permit Type: MISC ZEPHYRHILLS, FL.
Class of Work: RIGHT-OF-WAY Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 11-26-21-0010-00800-0260
Improv. Cost: OWNER INFORMATION
Date Issued: 6/20/2 Name: CHARTER COMMUNICATION
Total Fees: Address: 30432 SR 54
Amount Paid: vet_z_�Jl WESLEY CHAPEL FL 33543
Date Paid: Phone: 813-918-7935
Work Desc: MIS DESCRIPTION 5935 7TH ST-FEE WAIVED
CONTRACTORS APPLICATION FEES
CHARTER COMMUNICATION
i f
Ins ections Required
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
4glll d-z�� &-,
CONTRACTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
_ CITY OF ZEPHYRHILLS-BUILDING DEPARTMENT
DATE: RIGHT-OF-WAY USE PERMIT PERMIT#
No construction under ground or above ground of any facility shall be accomplished on any City Rights of Way without written approval from the
City Building Department.Any application for approval of construction operations on any City owned Rights of Way shall furnish a detailed drawing
showing the complete scope of the proposed work in triplicate to the office of the Building Official for approval prior to the commencement of any work.A
copy of this permit is to be kept readily available at the site of the work at all times.
PARCEL I.D.# 11-26-21-0010-00800-0260 CITY ROAD 7th Street
DATE 9
LOCATION(Legal Description): 5935 7th Street,See attached legal description
Permission is hereby granted to Charter Communications of 30432 SR-54 WESLEY CHAPEL,FL 33543
for the construction and maintenance of-
Installation 1458ft of new cats conduit&cable within road right of way
_subject to the following conditions:
1. The construction and maintenance of such utility shall not interfere with the property and rights of a prior occupant.
2. All work shall be done in keeping with the standards of the City Streets Department and under the supervision of the City Building Official,who
will be notified at least one day prior to commencement of construction.
3. All materials and equipment shall be subject to inspection by the City Building Official.
4. During construction all safety regulations of the Department of Transportation shall be observed and the City shall be relieved of all
responsibility from damage of any nature arising from this permit.Subject to the same terms and conditions,the permit holder may take such safety
measures,including placing and display of caution signs,as it may deem necessary in conduct of constriction and maintenance work hereunder. It is the
responsibility of the permittee to????
5. All private and all City properly shall be restored to its original condition as far as practical in the opinion of the City Building Official.
6. All underground crossing installations shall be laid at such depth as may be specified by the City Building Official.
7. The sketch covering the details of this installation shall be made a part of this permit.This permit is granted with the understanding that the
applicant has notified all other utility users in the area covered by the permit and takes full responsibility for any damage incurred by prior installations as a
result of his operations in order that they may safe guard their interests.
8. It is expressly stipulated that this permit is a license for permissive use only and that the placing of facilities upon public property pursuant to
this permit shall not operate to create or to vest any property right in said holder.
9. Whenever the City decides to further exploit the City Rights of Way,any or all said poles,wires,pipes,cables,or other facilities and
appurtenances authorized hereunder,shall be immediately removed from said Rights of Way,or reset or relocated thereon as required by the City Building
Official at the expense of the holder of this permit.
10.The holder shall save and keep the City harmless from any and all damages,claims,or injuries that may occur by reason of the construction,
maintenance,and operation of said facility.
11.The holder shall complete the requested work within days or this permit shall become null and void.In the event the work
requested is not completed upon the expiration date of this permit,the City shall have the right to complete such work and to charge the holder of the permit
for all costs incurred in completing said work.
12.The holder shall post a cash or surety bond with the City Manager in the sum of$ dollars to guarantee performance of the
obligations herein,and to guarantee maintenance of the right-of-way described herein for a period of one(1)year following completion of the requested
_ installation.In the event a surety bond is posted,the surety bond shall be made payable to the City and shall obligate the surety to hold the City harmless in
the event the holder of this permit should fail to meet any of its obligations hereunder.The bond shall also indemnify the City for all court casts and
reasonable attorneys fees in the event legal action is required to collect on said bond.
4 SUBMITTED BY:
(permittee)W f L k-•'d �Z c /1/l.
I.
Signature&Title&Vn
Address 6Y 3 2 1U .S k,., �/�a..0e/.>�` 3 3, /
APPROVED BY:
CITY OF ZEPHYRIIILLS '^
Building Official , ` l Ails
Date: �/0'� T
Utilities Supervisor
Date: LetDateicWork ` DOW 6—v`< ec_SCD ��
Date:
City Manager
Date:
.... .. ..... .... .......
JOB LOCATION 'MAP
q.
...... ... General Notes..
_..
%ElamatitaVoodiand
> ,E I,L A N ID P,A`R K -.:. i:J ry hoof`. .• 1.All Gaty Construction within the Public I loI of W shall be in conform
T O W N.H O'N4,E S /r „ SIC 0 l:i, _ with the local JurlsdlctioW "Minimum 5tandards"
.. . .. /.
TTSD.ALE''
Heartland of Zephyrhilis a ... f, and meet N.�.S.C„F.C.C..M I1,T.C,D,and F,D.0,1.standards.
G R E E N' 1i 1 L LS =.r:,,=ynp�,� '•'.. " i i' ""' 2.flee conracta shall notify'Call sunshine and otherudItIc5 prior to
6 PIARKIIHII LiL,
E S,T A.T,E,S - 'L i) a:_i commencement of construction.:
'Z E RHI Y..R R i.D.;GI E United States flan=` I :;t I=. 3.Use the.:Directlonal Pore Method' for Al Poadway.&driveway crossings,
(F ... � ....
1 Postal Service ., `:;O:A-K;.:P.A R Kt' no"accupunture missle bores pennitted.
- a`N E_.G R O V'.�s -j-- -;NnnA'Ave, __ q,No en as halt cuts will be ermined unless e-a roved
A'I7.D.I T'I,0 N r. "" W p p p Pp
4 ::; l 'rx `I-.' _ Must Peter to Pasco Canty Open Cut.Detall
+O'RE,Sf;)VILLAS: ¢.is ri_F- s: ,; , r '(, .
• ;f t "f asco Canty Englneerinq 5ermces Peslgi Standards,Index No,102"
WED G'E,W,0 0 D.. n ::wn.•,.r '�\.. a r, l'.r.l_
5.All side walk removal and replacement shall be restored to
K7:AN�OR .DOWN'g,;...,'.i:! .;,: ... ;.;' a` ,,I{'i li'1 .. p
A D D-1 TA 0 N.:j;1',:',Pank•of Arnedca:..R,', :..'4:`;,';,., t .'..::J_L ,1 I . . the local JurisdlAicn's and F,I7,O,T,Standard 5pecificabcn No,522
..TO Ci T Y.:'OX -'.'Financia,`Center. @y jtS Stewart' ,' I i;^'' j'' ,, _ _,_ _ 6.•:AI aerial construction-shall maintain a minimum of 15'clearance parallel to..
tl _
ZE'PH'YRHILCStcy ,_'s,:'c`q> ;; =
':
'I all F D 0 f C & I I al PI hts rocs a c of Way.
00',4!li 7.Nlust maintain an minimum 3 learance from all water&sewer hr�es:
Middle
S P '•' "'' ,, ., 'B Department cf Public Works;Htilitles InspectionDivision shall be notified
t.
castru',�:-. 'Mapdata'®2018;
Gom
.. ., _. c ...
- three(3)working days prior to canmencemerrt o f
..i 9 IJndergrand uttlitles have been plotted from avallble records and...
field obervatim5,but are not necessarily exact.fherefore.utillttl IocaLicns
... .. .. .. .. .. .... .. .. .. ..... :.:... ... ... ..... .. ...
will be verified IOOft In'advance of trenching;plowi rq and borlrij.
56 that cahanges can be made in event of conflict.
.... ..... s 10 P.e*ration shall 6egln within three(3)week after the Installatla
ee .
of cable/conduit.Full,craes by s d and,mulch or soddinq as approved
o open trenches to be eft open wemlght.Needs to be backflled .
or covered.'(Public 5afety Hazard.)
12.No excaJ4icn shall be permitted within 10'of'protected trees
" -- - -" UTILITY LEGEND : "" ':: :' ":' " ':: utility Instellation be;placed by dire ore
(20'for Grand;0aks) Al shall ctla al 6
R begininq akt ide.of protected.radiu9;
x PWR WOOD POLE l3.Erosion Control Measures must be used at all times.
EOP
® PWR.CONCRETE POLE --------- — CENTER LINE M.Nse drawings'a e;for pe m ttlnq purposes only.
5 All pr o5e utility'located within roadside drainacle ditches shall be a
IM PWR.STEEL POLE - - —- - . POWER minimum of 30"below the lowestpoint of the,ditch or tne invert of any
)K ST LITE :COMM s. culverts:withinricIR of..way.whicheverlslaver..'
....... .......
® JOINT USE,TRANS -' —" — TELEVISION 16.NI materials used for 6ackfill shall be free from lax-oe lumps,clay
® JOINT USE — — — — WATER. word or other exfraneaate s mrial;FDOf 55 5ectlon125 8
e' FIRE HYDRANT —- — —- — SEWER Packflllinq shall be redone according to FPOf 55:5ectio6 125-
®--® 'CULVERT ——— RECLAIM y raulem o on I Itoft?9cepta ctoac f-8
under wet conditions shall caform'to FDOf 5 Section 125-8
STORM DRAIN. GAS
PROJECT NAME:5935 7T '
"APPLICATION CITY OF ZEPHYRHILLS'PERMIT :"" ""' H.ST... :COUNTY:PASCO
-' ® LACE CONDUIT IN CI WAY
DATE:6-6-19 : : : SECTION:II TOWNSHIP:26 RANGE:2I
TO
C h a rte r,,,. o ,w E - P NEW COND .. ENGINEER BRAD LANG'_ DRAWN BY:K.L. '
U CABLE WITH CITY RIGHT OF
JOB DESCRIPTION;: PRISM NUMBER:1291627 "NTP#:469478 SCALE:NONE
"'CATV UNDERGROUND CONSTRUCTION "'"
""" ""' TYPE OF'PERMIT:CITY "TRACKING#•: DRAWING SHEET:I OF6 "'
''ROAD
WORK
END .AHEAD
ROAD WORK ��°
f A
A
B Taper Length=%L Work Area j *'
y9= y See Table(f Table 11
✓'ROAD —"# \ / RoaD woRK Taper Length Shoulder
a' WORK Device Spacing-Taper .j.,Device Spacing-Tangent s0O
\AHEAD \� See Table f See Table I Speed )3L 00
SPEEDING FINES (mph) 8' 10' 12' Notes
�`a DOUBLED
4 wrEN WORKERS \\ Shldr. Shldr. Shldr.
PRESENT
25 28 35 42
Table I 30 40 50 60 L=WS.
Device Spacing 35 55 68 82 60
Max.Distance Between Devices(ft.) 40 72 90 107
Speed Cones or Type f or Type fl 45 120 ISO ISO
Barricades or Vertical
DISTANCE BETWEEN SIGNS (mph) Tubular Markers Panels or Drums s0 133 167 200
Spacing(ft.) Taper Tangent Taper Tangent 55 147 183 220
Speed A B 25 25 50 25 50 60 160 200 240 L=WS
40 mph or less 200 200 30 to 45 25 50 30 50 65 773 217 260
45 mph 350 350 70 187 233 280
50 mph or greater Soo Soo 50 to 70 25 50 50 100
"Midway between signs. 8' minimum shoulder width
t/3L= Length of shoulder taper In feet
SYMBOLS GENERAL NOTES DURATION NOTES W= Width of total shoulder In feet
(combined paved and unpaved width)
OWork Area 1.When four or more work vehicles enter the through traffic lanes In a one hour 1.Signs and channelizing devices may be omitted If all of the
period or less(excluding establishing and terminating the work area),the advanced following conditions are met: 5= Posted speed limit(mph)
■ Channellzing Device(See Index 102-600) FLAGGER sign shall be substituted for the WORKERS sign.For location of flaggers a.Work operations are 60 minutes or less.
and FLAGGER signs,see Index 102-603. b.Vehicles In the work area have high-intensity,rotating,
flashing,oscillating,or strobe lights operating.
[]I Work Zone Sign 2.SHOULDER WORK sign may be used as an alternate to the WORKER symbol sign only
on the side where the shoulder work Is being performed.
Lane Identification+Direction of Traffic
3.When a side road Intersects the highway within the TTC zone,additional TTC
devices shall be placed In accordance with other applicable TCZ Indexes.
CONDITIONS
4.For general TCZ requirements and additional Information,refer to Index 102-600. WHERE ANY VEHICLE,EOUIPMENr,
WORKERS OR THEIR ACTIVITIES
ENCROACH THE AREA CLOSER
THAN 15'BUT NOT CLOSER THAN
2'TO THE EDGE OF TRAVEL WAY.
LAST1�',FDESCRIPTION: FY 2019-20 INDEX SHEET
REVISION FDOY� TWO—LANE, TWO-WAY, WORE ON SHOULDER
11101117 �— STANDARD PLANS 102-602 I of 1
o:
PLANVIEW OF CATV UNDERGROUND CONSTRUCTION
0
�5
....
Proposed 34ft Coty Cables & (1)•2'eHDPE Innerduct I 2� "
w w°
nt of18`
.. ..Proposed placement of - ' .... .: ..
... ... Directional Bore Minimum 48" depth:-:;:' :" I .. ... ...... ... .. ..
•a; 1019ft Catv Cables & (1) 2' HOPE Innerduct Refer Directional.Bore Profile D I V� Q Proposed placement of
r Open Trench"Minimum 36 depth _ ?`
...I ... �`�( 282 Caty Cables & (1) 2° HOPE Innerduct
�...
Refer 0 en Trench Profile C ft
P i i Open Trench Minimum 36" depth
shop" - ;: Refer Open Trench Profile E
End construction
. dw Pole.#441885 .. � 7.„. •,dw dw ." .I 7 dw
... ... .. .. Y .. .... .. 125..... ... ...
30'... 1,13:, 7` 7
bore .. .. .. .... bore 77'bor 'S' 13
oe
.. .,_.. grass �gra'ss"— i— _ grass -
16' 2 t6' 2 16" 2 �L 2 ,.
. -----=- ----`=-�--'--=`----- -_---_..... I ,.:. : I ------------------- -- — —'---
7TH ST b -
sw -- - - sw _ sw -
= -------------------- - ------------- ------ - -- --
dw - -
" grass :: <I grass grass'-
�.I. i.'. .. dw
NOTE: ALL EXISTING UTILITY DEPTHS& LOCATIONS BASED-ON'A
STANDARD, AVAILABLE RECORDS:AND FIELD OBSERVATIONS.
WILL REQUIRE UNDERGROUND LOCATES PRIOR TO CONSTRUCTION.
A MINIMUM OF 24" VERTICAL AND 24" HORIZONTAL SEPARATION
FROM EXISTING UTILITIES MUST BE OBSERVED. .. .. .... - .. ... .. .. .. ... ..
..
A MINIMUM OF 18'" VERTICAL AND 36" HORIZONTAL SEPARATIONFROM EXISTING GAS MAINS MUST BE OBSERVED. '" 'p' p - .
...... ... ... .. ... PROJECT NAME:5935 7T - COUNTY•PASCO
+ w APPLACE IT& E ITHIN CI WAy DATE: SECTION:II TOWNSHIP:26 RANGE:21
LIGATION CITY OF ZEPHYRHILLS�PERMIT _
Charter. s N TOP NEW CONDU CABL W TY RIGHT OF ENGINEER:BRAD LANG DRAWN BY:K.L.
JOB DESCRIPTION: PRISM NUMBER:1291627 NTP#:46947R SCALE:1"=50'
- CATV UNDERGROUND CONSTRUCTION w: w TYPE OF PERMIT:CITY -TRACKING#: DRAWING SHEET:3 OF 6 "
PROFILE E-.
TYPICAL CAN TRENCH/DIRECTIONAL BORE PARALLEL TO ROAD ROW,
7TH'ST LOOKING NORTH
Row :60' Row
TYPICAL CATV RISER DETAIL
.17': Eop 13' :C/L 13' Eop, 17' -
.... .:. .. .. ... .. ....... ... ... ,. .. ... .. .. ...: .. lines
ondaryopower lines
utility poleprimary
sw
grade "" '{�""'^' I grade- secondary power lines
.. .:24 -- — -----r----- --------=--i------==---- —=----`-------- ----24"' .. .. utility lines .40° min.
other ut
.• ... .:.
.. .. ... ...... ..... .. ." .. ., ... ... 12 min
....30 ---==----------------- ----------- ------------ ---------------- —=--30"., caty lines
.. ... •1, ..29* ...... ... ... ... 2".schedule 40 u— uard
/steel riser u— ua d
• 18' 9
36"---- ----0--gas--- ----------- — -----=-- -------------- _36�� 18' min-- .. '
--- —
own u
. ....... * ... .. .. ..i...' ... * ... .... .... ...
.. .. .. —.— -- -----.—.—.--- — . 1I — — — ----�I—42!--7— ------ -- -77. .. .. .. .. gra.d.e
O
swr60" - -- - ----------- '------------ ... ... _ _
---------------------60 36" Rein.
.. 72"---= -------------- -------- ----------- _72".... .... ... .. ...
Proposed placement of
'282ft Caty'Cables &(1) 2"'HOPE Innerduct
Open-Trench Minimum:36" depth
.'STANDARD TRENCH DETAIL '
.. .. .... .. .. .. .... .. MIN..
1RFN SNNL 6E a�W(Nla]iN
.urrs Nor ro en®u•.wo aauaxc
.nl.YWYIIY RN9tt aT BBL AS
3 �y b 36;MIN..,12. 7B' � Rt T tea
NOTE: ALL EXISTING UTILITY DEPTHS& LOCATIONS BASED'ON:A
'$• 2• 6• MOTOSm OPE/ewaXRE a Ca
STANDARD. AVAILABLE RECORDS AND FIELD OBSERVATIONS. SS
...:. .:.. ...... tl .tl: 2•
WILL REQUIRE UNDERGROUND LOCATES PRIOR TO:CONSTRUCTION.
A MINIMUM OF 24,' VERTICAL AND:24" HORIZONTAL'SEPARATION
FROM EXISTING UTILITIES MUST BE OBSERVED.
.. .. .. .... ..... _ .....: .... ..... a .. ..m m xo�-m:.—T
A MINIMUM OF 16" VERTICAL AND M'"'HORIZONTAL SEPARATION s
FROM:EXISTING GAS MAINS MUST-BE OBSERVED. - - :
... ... .. .. ...
APPLICATION CITY OF ZEPHYRHILLS PERMIT
E
N TO PLACE NEW CONDUIT&CABLE WITHIN CITY RIGHT OF WAY DATE:
4-6 9ME:5936 7TH ST COUNTY:PASCO
SECTION:11 TOWNSHIP:26 RANGE:21
Charter W®M " ENGINEER:BRAD LANG DRAWN BY:K.L.
�..,,.. ._JOB DESCRIPTION; . .....
9 PRISM NUMBER:1291627 - -NTP#:46947R SCALE:NONE
CATV UNDERGROUND CONSTRUCTION '
...:. TYPE OF.PERMIT:CITY .TRACKING#: . .DRAWING SHEET:6 OF 6
_ _ - .
PLANVIEW OF CATV UNDERGROUND CONSTRUCTION
Proposed placement of
80ft Catv,Cables & (1);2 HDPE Innerduct'' proposed placement of "• •• Proposed placement"of
.Open Trench Minimum 36" depth 1019ft Catv Cables & 1 2" HDPE Innerduct
Refer Open Trench Profile A. 43ft Caty Cables& in 2" HOPE Innerduct "" - i )
�' Directional'86re Minimum"48" depth � ����� � �; ""' Open c depth
'Trench Minimum 3fi"
3 3 Refer Directional Bore Profile B _ Refer Open Trench Profile
0 o:
.. ... 1— _ .......
.Begin construction at ::o o .. ::.... .. ..... o .. .. ..
Pale 043330 w 2.4.w i �/� ,/ r
Riser ... ..... .;18' ' .1 a.— ... .. ... .. {?a✓u!y .... .. ....... .. ..... /r .. .. ...
I � I Jrtd Gov.
y."Pale 4017444 .. r
dw dw dw dw dw _ dw ✓+
74' Pole'# 771169 Pole #2770792
28' 7' 13' T—r'2fi Pole 441�87
1 .. .. 30' 36' I ... 33 .. "32' .. .. ..
26'bor,
Ro 17 bore _ _ _ bare_ bole -
_� ,
Ea p ..16.. 2 r .' 16' 2 ' 16, .2
:6 2 CAL ----.. -- -----------...-L--- --rt---- ---�---.----��-- ---- --------------------'—'
�. .7TH ST I ... ,.
Ea _.._.__-----
I
s
.grass Q .: grass
jE
dw dw
.. .. .dw. ..:..dw ,dw .... ..
is
.. ... .. .. ... ...
NOTE: ALL EXISTING UTILITY DEPTHS & LOCATIONS BASE D-ON"A
STANDARD, AVAILABLE RECORDS AND FIELD OBSERVATIONS.
WILL REQUIRE UNDERGROUND LOCATES PRIOR TO CONSTRUCTION.
A MINIMUM OF 24' VERTICAL AND 24" HORIZONTAL SEPARATION.
FROM.EXISTING UTILITIES MUST BE OBSERVED. .. ... .. ....... ... .. .. .... ..
A MINIMUM OF 18",VERTICAL AND 36" HORIZONTAL SEPARATION
FROM:EXISTING GAS MAINS MUST BE OBSERVED.-
' �" _ PROJECT NAME•5935 7TH
. .. .. .. .. .. COUNTY PASCO. .. _ ..
- APPLICATION CITY OF ZEPHYRHIILS PERMIT
W TO PLACE NEW CONDUIT&CABLE WI THIN CITY RIGHTOF WAY DATE:6-6-19 ,SECTION:11 TOWNSHIP.:26 RANGE%21
Charter s S® ENGINEER':BRAD LANG 'DRAWN BY:K.L.
. N
.E JOB DESCRIPTION: PRISM NUMBER:1291fi27 NTPN:469478 ,SCALE:I" 5a'
CATV UNDERGROUND CONSTRUCTION .: :" :TRACKING#:: DRAWING SHEET:2 OF 6
"• TYPE OF PERMIT:
PROFILE C „ —PROFILE D
TYPICAL CATV TRENCH/DIRECTIONAL BORE-,PARALLEL TO.ROAD ROW TYPICAL::CATV DIRECTIONAL BORE CROSSING ROAD ROW
7TH ST LOOKING NORTH 15TH AVE LOOKING WEST
Row, 60 . Row Row .60': Row
p
Eo .. :13' C/L.. '13' Eo'p.:. 17' I ;18'; Eo .. 12' C/L 12' EOP:. 18': i ..
.. 5' sw:. rode ..... ... rode
grade ^�..r.{.w...... _ grade g _ g
.. 24"----�---------------------------.' .-1--------- - .:. ---�----_24" ---- ---------------- ----------- II------------ ---------------- ----24
30 I--------------------- -I-•------------ -=--------=-=-==I-----30". 30"---- -----------------------------I------------ -----------------
16' , 5' 5
36��---- ------ -----7----- -------- --- - ---36". 36 ---- - ----- ----- -r--------- ------------ ------- w-t7---- -36 ..
II
comO--O OwTr '1'-- OwFr------- -*- - *--- ..
gas
JA
.O
I60 ---C-- ---------------------------------------- --------------- 7--60" 60 ---- ----------------- --------- - ------------ --------------- ----60
I I.
72 t ..
.. :: Proposed placement .. ..
-_ e ement of
Proposed placement of 34ft:Caty Cables &'(1)•2"-HOPE Innerduct.
.. .. ..
1019ft Caty Cables & (1)�2" HOPE Innerduct� ' " :� : Directional Bore Minimum 48 depth
Open,Trench Minimum,36" depth
... .. .. ... ..... ..... .... .... .. .. .. .. ....
NOTE: ALL EXISTING UTILITY DEPTHS&LOCATIONS BASED:ON A -
STANDARD, AVAILABLE RECORDS AND FIELD OBSERVATIONS. -
WILL REQUIRE UNDERGROUND LOCATES PRIOR TO:CONSTRUCTION. .......
A MINIMUM OF 24" VERTICAL AND 24"HORIZONTAL SEPARATION
FROM EXISTING UTILITIES MUST BE OBSERVED.
A MINIMUM OF 18" VERTICAL AND 36"-HORIZONTAL SEPARATION -
FROM EXISTING GAS MAINS MUST BE OBSERVED.
APPLICATION CITY - .
� - .N • . ..A OFZEPHYRHILLS PERMIT � DATE:6-6-9PROJECTINAME.59357TH - SECTION:II TOWNSHIP:26 RANGE:21
Charter ` " yv®E TO PLACE NEW CONDUIT& ITHIN CITY OF WAY ENGINEER:BRAD LANG•• DRAWN BY:K.L.
N CABLE W Y RIGHT
r' f ' 70B DESCRIPTION:: "": : PRISM NUMBER:1291627 NTP#:469478 SCALE:NONE
"S CATV UNDERGROUND CONSTRUCT ION TYPE OF PERMIT:CITY :;TRACKING#: .DRAWING SHEET.5 OE 6
PROFILE:
A:' — .. " PROFILE B
TYPICAL CATV;TRENCH/DIRECTIONAL BORE PARALLEL TO ROAD ROW TYPICAL CATV DIRECTIONAL BORE CROSSING ROAD ROW
Pole 43330 7TH ST'LOOKING NORTH 12TH AVE LOOKING WEST
Riser .. .. .. .. .. .. _.
Row 60' Row Row 60, - Row
;13,_ C/L 13' EoP':..... 17' :: .. ..:... 18' Eo.:...12' C/L. .. 12' EoP .. 18':. :.. ..
.. ..5—sw 5' sw .
.grade grade': grade ., grade
24" --- ---- ----------- -----------y------------ -------.---------�--- 24" 24' ---- -------------7--- -----------1------------ ----------------
:,. .. .. .. .. ...... .. .. ..:.... ... .... .. ....
30"----A�— -------------- ---29r------'------------ ----------------v----30" :. 30.,---- ----------------- ---1 7r --- ----Zsr----- ---------------- ' ----30"
.. 16, .. .. 14' .
.. .. . � � � 36"
36" ——— 36" 36" -- ---- -----------��— — -------- --- _—_—_ ----
gas � -- pwFr -- - . .. ..
42" ___—____ _____----_—_____- _ 42 48" = —_--_—___ _ ________ ------ _ 48"
....
so
.....
-_-^
60 -----{-- ---------- ------- �-------=---- --- ---- r-----60". 60"--�------------------- -------- --�-- ------ -- ----------v----60".
... .. ..
i Proposed placement of Proposed placem_en,t of
:80ft Catv,Cables & (1) 2":HDP•E Innerduct' .. .: 43ft Catv.Cables & (1),2".HDPE Innerduct.
Open Trench Minimum 36" depth Directional Bore Minimum 48" depth -
TYPICAL UNDERGROUND CAN DRIVEWAY CROSSING '
....,.. .. .. varies. ...
conc./asphalt
.. ..,.,.� .. ..... ... 36" min. .. .- 5,.. .37rn, 5,• � � 36" min. ...... ....
NOTE: ALL EXISTING UTILITY DEPTHS &LOCATIONS BASED:ON A
STANDARD, AVAILABLE RECORDS�AND FIELD OBSERVATIONS. •
WILL REQUIRE UNDERGROUND LOCATES PRIOR TO CONSTRUCTION.
A MINIMUM OF 24" VERTICAL AND 24" HORIZONTAL SEPARATION '
FROM EXISTING UTILITIES MUST BE OBSERVED. ...... .. .. ... .. .... Casing size'varies
A MINIMUM OF 18" VERTICAL AND 36" HORIZONTAL SEPARATION Proposed Catv
FROM EXISTING GAS MAINS MUST.BE:OBSERVED.: :: .: '::.':' :':: :':' HDPE Innerduct ,
... .. .
i ® APPLICATION CITY COUNTY::IASCO
DATE•6 6 19 � SECTION:11
Charter i w E TO PLACE NEW CONDUIT& WITHIN CI F WAY ENGINEER:BRAD LANG DRAWN BY:K.L.TOWNSHIP:
OF ZEPHYRHILLS�PERMIT
CABLE CITY RIGHT 0
JOB DESCRIPTION::: PRISM NUMBER:1291627 NTP N:46947R SCALE:NONE
9 CATV UNDERGROUND CONSTRUCTION
... .. .. ....... .... .. .... ... ::. TYPE OF PERMIT:CITY :: ':TRACKING#::: :. .DRAWING SHEET.:4 OF 6 .. .