Loading...
HomeMy WebLinkAbout19-21494 CITY OF ZEPHYRHILLS S335-8TH STREET (813)780-0020 21494 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:21494 Issued: 7/12/2019 Address: 7018 SILVERADO RANCH BLVD Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): ' Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 266,079.30 Total Fees: 14,897.69 Subdivision: SILVERADO Amount Paid: 14,897.69 Date Paid: 7/12/2019 Parcel Number: 05-26-21-0100-00700-0130 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: D.R HORTON Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TAMPA, FL 33637 Phone: Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 2,362 SQ FT APPLICATION FEES PLUMBING FEE 206.25 ELECTRICAL FEE 309.38 MECHANICAL FEE 144.38 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,477.49 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 � C Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. l CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER D.R. Horton-7018 Silverado Ranch Blvd:2,362 sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 1,375.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,477.50 ELECTRICAL: $ 309.38 PLUMBING: $ 206.25 MECHANICAL: $ 144.38 SUB-TOTAL $ 2,137.50 TOTAL $ 2,137.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,690.85 PARK IMPACT FEES $ 769.56 SIPS: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 141897.69 INSTR#2019112808OR BK9933 PG2376 Page 1 of 1 07/03/2019 02:30 PM Rcpt:2069388 Rec:10.00 DS:0.00 IT:0.00 • Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller,ad Interim Permit No. Parcel ID Nov's-a(p-Cal-Q Im- 00700 01-6c) NOTICE OF COMMENCEMENT state of Florida County of- Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement I Description of Property: Parcel Identification No.___ 7!t' 1-6 Street Address: 'S I I_wakio-Raxy_r\ Blvd-Ze btm ch 11s EL Z65±* _335 2. General Description of Improvement New Singige Family Residence- 3. Owner Information or Lessee iriformation If the Lessee contracted for the improvement D.R. Horton, Inc Name 12R02 Tt-lt-rnm Drive Tampa 33637 Address city State Interest in Property: Fee Simple Name of Fee Simple Titleholder: (if different from Owner listed above) Address city State 4. Contractor. D.R. Horton, Inc Name 12602 Telpcom Drive JaMPA 33637 FL Address city state Contractor's Telephone No-: S. surety: N/A Name Address city State Amount ofEl6nd: s, N/A Telephone No.: 6. Lender N/A Name Address city State Lendefs Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713,13(1)(a)(7),Florida Statutes: David Gude Name 126Q2 Telecom Drive Tampa 33937 - FL Address i City State Telephone Number of Designated Person; 813-740-9720 8. in addition to himself,the owner designates NIA of toreceive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner 9. Expiration date of Notice of Commencement Me expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signature of Owner or Lessee,or Owner's or Lessee?s Authorized Officer/Director/PartneriManager Assistant Secretary/D.R. Horton, Inc Signatory's Titte/Office The foregoing instrument was acknowledged before me thisW( day 0fZLU%;iF_ 20'0 by "TO d as.Assistant Searatm)t (type of authority,e.g.,officer,trustee,attorney In fact)for D.R. Horton, Inc (name of party on behalf of whom instrument was executed). Personally Known 5&1X Produced Identification 0 Notary Signature Type of Identification Produced Name(Print) DANA kNNE NAGHTM p'btic.state Of Floridallolaty �i,,# G13 010660 rommis 0 MY cc)JIM.Expires Jul 12.202 1 wpdatalbcs/noficecommencemenLpc053048 ti E PASCO COUNTY, FLORIDA Permit No. 2— 1 Date Permitted _2—/2-/'7 Builder Name/Owner Name � T�t � � Control#' pp County Parcel No. f? "- O/OD 00 �0�<30 SubDiv: fee Address/Location 70 th Is, UL' 149114 4 ll/D 1 Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 24c3� Exempt ❑Yes [} No How Determined Impact Fee Amount $. r &3 Zone No. TAz: I SCHOOL IMPACT FEE I t Account (056) Single-Family Detached House Amount $ 7� 90,.2.6 (057) Mobile Home x (058) Other Residential 123) Collection Fee Exempt �Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How oetermined r LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount _ I RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE i . BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply rece! t of a co of this form placing 9 PY P PY P PY �P 9 the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY K y. D Q t �J- Single Family Dwelling Plan Review Comments 1. F.F.E; shall be a minimum of 8" above the road elevation and an engineered site plan. I Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides_ of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered_and marked at time of first inspection. 8: All A.D.A. requirements shall be met: 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical.damage unless protected by approved barriers. M303.4 of the RB.0 12. Water heaters shall comply with section P607.3 of the F.B.C.. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308:1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. `-`Green gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. It accordance with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure. 25: R403.5.3Hot water pipe insulation Insulation for hot water'pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping 31, inch (19.1 mm) and larger in. nominal diameter. Piping serving more than one dwelling unit. Piping located outside the conditioned space:, Piping from the water heater to a distribution manifold: Piping located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower door test shall be provided before C.O: 26.A copy ofthe enerzy cacls shall be with permit at all times. 27. CoPV.of final insulation report shall be provided ivith permit before fnaL 28 No knee, pool or screen enclosure .is issued with-this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) v L„ City of Zephyrhills Permit Application Fax=813-780-0021 Building Department Rate Received � �,'�t,�h�,,�€,:.��_^ `7�'r_d�'><"� f�-,^ P-•"�G�" ���'. � Phone Contact for Permitting -- Owner's Name i ;- cs r-, Owner Phone Number I Owner's Address "52ow' ner Phone Number Fee Simple Titleholder Name ,v i. Owner Phone Number Fee Simple Titieholder Address f JOB ADDRESS [�12> 7SPJ'Vemdo2COC19u iQ r LOT# t 3 SUBDIVISION PARCEL iD# (OBTAINED FROM PROPERTY TAX NOTICE) ' W014K PROPOSED NEW CONSTR ADD/ALT SIGN 0 DEMOLISH 'INSTALL. 8 REPAIR PROPOSED USE SFR 0 COMM OTHER TYPE OF CONSTRUCTION . ��'' BLOCK CJ •FRAME STEEL C]p^ DESCRIPTION OFWORK �n�L Jal!� �cvL� � 5m� e.' .7c� BUILDING SIZE SQ FOOTAGE +�_ZVR i HEIGHT 'rr-rl�-r"rrr-rr r--rrs"r'rrP-rnrr-In"r-rTc-ra-r-i--rr'It-rrr-r'Y-r'rQ-ri-t"i-r-r-P-r'rrt-Ili-r-a a I a~Q-r- BUILDING $ afl 1ow VALUATION OF TOTAL CONSTRUCTION DELECTRiCAL $. �! wo AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBiNG $ '� a MECHANICAL $ CW VALUATION OF MECHANICAL INSTALLATION f =GAS [ ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS , FLOOD ZONE AREA [ YES NO .p..1...I-1-�•-o...a-;.-g..�_�p-p-.r.-.p..•;-�1--F-c� 1a--1--I�(�i�-o..l..,l-:-�.y-p..:-1-i..;-:-�.,�.-1-G-:•.4-1-a-a-E-a�•l•-a•-Fr-:-1,•�..�➢a.;�,-°.�-1-1-.p..�.� BUILDER "�f _ �� COMPANY ' SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address /c�li[3,? ,rr y License# ' � 7� ' I ELECTRICIAN s .r �' - COMP ANY 31GNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# Q� SLUMBER COMPANY 31GNATURE REGISTERED Y I N FEE CURREN Y/N Address � r ! �i� 'iJ� y - License# l AECHANICAL COMPANY > ' SIGNATURE 1 Ems' rG�� ". .'_'_'REGISTERED YF/ N FEE CURREN Y/N Address ✓ `e�'r� A �'.. /� "� a jr�srul1`ee License# )THER _ .•>- - .-.. COMPANY 61 e' /4A11 d1? x .— ? 41 HGNATURE a" REGISTERED Y/ N FEE CURREN Y/N Address C'� License# F lillli �' iiilliliiii11i111i11i111111111111illlilllli111811 IESiDENTiAL Attach(2)Plot Piar.,.; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten (10)v.,orking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt.Fence installed, Sanitary Facilities& t dumpster;Site Work'Permit for subdivisions/large projects :OMMERCiAL Attach (2)complet( 3efs of Building Plans plus a Life Safety Page; (1)set of Energy Farms. R-O-W Permit for new construction. Minimum ten (10) )rking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities• 1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance ;IGN PERMIT Attach(2)sets of E:igineered Plans. ""PROPERTY'SP.-IVEY required for all NEW construction. 1-.f..1-�1-4-0-1••-➢-1-4-1-.8-1-1-i�.. .-i-8-d-.'�-i-f-�-�-i-i..tS.-�-.E-i-6-•Q-1-9-8-I-1�-�-•!-1.�.-1-L..�-d-.H-I�-k-{�.-i-6..1...�-6�A-1-.I�b-4.-6 '�.�d-.&.•a. lirections: Fill out application completely. Owner 4 Contractor sign back of. )placation,notarized If over$2500,a Notice of Commvneemerit is required. (A/C upgrades over$7500) Agent(for the-contractor)or Pow(.-•of Attorney(for the owner)would be someone with notarized letter from owner authorizing same 1VER THE COUNTER PERMITTING (copy of contract required) eroofs•if shingles - Sewers :service Upgrades A/C Fences (Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW . . NOTICE 0F DEED RESTRICTIONS: The undersigned understands that this permit may besub]kttu"deed" restrictions". which may be more restrictive than County regulations. The undersigned aaaurneorespnnnibUityfornunnpUencevvithany applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they rnoy be required to be licensed in accordance with state and local regulations. [ythe contractor is not-licensed as required by |avv, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intendad�oontraotor are uncertain as to what licensing requirements may apply for the intended vvork, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at727-847- ` OUDQ. Furthermo[e, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you,*as the owner sign as the oontn8[tor, that may be an indication that he is not properly licensed and is not entitled to perm|tt|ng privileges.in Pasco County. ' TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation Impa:ct Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing bui|dings, as specified in Pasco County Ordinance number8A'O7 and 90'07' as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving e "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pa000�County Water/Sewer Impact fees are due,they must be paid prior tb permit issuance |n accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chmptor713. Florida Statutes, as amended): If valuation of Work is$2.500.00 or more, | certify that |, the applicant, have been provided with a copy of the "Florida Construction- Lien Law—Homeowners Protection Guide" prepared by the Florida Department of Agriculture-andConsumer Affairs, If the applicant is aonnaona ctherthantha °ovvner". \ perbfvthot | haveobta|nedaoopyoftheabovodesoribeddoounnantandpromiseingoodfaithto deliver itto the ^ovvner' prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and. land development. Application is hereby made to obtain e permit to do.work and installation as indicated. } certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating oonotruntion. County and City codes, zoning regulations, and land development regulations. in the jurisdiction. | also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to*: ' Department of Environmental Protection-Cypress Bayheada' Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. ' Southwest Florida Water Management Dintr\ut-We||a, Cypress Buyheada` Wetland Areas, Altering Watercourses. . ' Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' - Department of Health 8k Rehabilitative Sen/ines/Envinonnnenta\ Health UnU-NaUa. Wastewater Treatment,.. Septic Tanks. ' US-Environmental Protection Aganuy-Aobe8toaabatement. - Federal Aviation Authorhl+Runvvayo. | understand that the following restrictions apply kzthe use of fill: - Use of fill is not allowed in Flood Zone"V~ unless expressly permitted. - If the fill material is to be used in F|ood Zone "A'. it is understood that a drainage plan addressing a "oonopanaeting volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State ofFlorida. � - If the fill material is to be used in Flood Zone "A" in connection vvith a permitted building using stem wall construction, Ico�Uv that�U\�iUbe used only toh||the area vv�hinthe stem wall. ' If fill material is to be used in any araa. | certify that use of such f||| will not adversely affect adjacent . properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one /1\ enro which are elevated by fill, an engineered drainage plan is reqUinad. 'if I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that a separate permit may be. required for electrical vvork, p}umbing, signn, vve||a' pools, air conditioning, gas. orothorinataUaUnno not specifically included in the application. A permit issued �haU be construed to be a license to proceed with-the work and not as authority to violate, oanna|, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter - requiringaconeodonofennnainp\ana. construut(onorvioia1{onoufanyoodaa. Every permit issued shall become invalid unless the work authorized by such permit is commenced within mix months of permit issuance, or ifwbrk authorized by the permit is suspended or abandoned for a period,of six (6) months after the time the Work is commenced. An extension may be requeutad, in writ|ng,from the Building Official for a period not to exceed ninety (90) days and will demonstrate ` justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE 0 .F COMMENCEMENT MAY RESULT IN YQOB� PAYING TWICE FOR IMPROVEMENTS T0 YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANK�NG, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.' - --_�- OWNER OR AGENT CONTRACTOR Subscribed an*d sw to(or affirmed)before,me thi`Z__ s Subscribed and sworn to(or affirmed)before me this _95 by Who is/are personally known mmevrxa*ouvvproouoeo Who is/are ppmonal/y known nomep,has/have produced as identification, as identification. ' Notary PublicNotary Public ` ` ' Commissmn No. Commission No. Nam _- of Notary typed,_ '-_--_ stamped _--N-_r,typed,printed or stamped PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 13, BLOCK 7, SILVERADO RANCH SUBDIVISION PHASES 7, 913, 11A AND 11B AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 6,402 SQ. FT. Curve Table LIVING AREA = 1.828 SQ. FT. Curve/} Length Radius Delta I Chord Bearing Chard GARAGE = 430 SQ. FT. ENTRY = 16 SQ. FT. C1 52B2' 2060.00' 128'09' NO2'56'57'W 5Y.82' LANAI = 88 SQ. FT. C2 49.62' 1935.00' 128*09" S0256'57'E 49.62' PATIO = 0 SQ. FT. DRIVEWAY = 497 SQ. FT. C3 508.34' 2100.00' 13'52'09' SO420'33'E 507.10' A/C PAD = 12 SQ. FT. C4 176.17' 2100.00' 4.48'24' SOo11'20•W 176.12 WALKWAY = 28 SQ. FT. IMPERVIOUS = 45% C5 33217' 2100.00' 9'03'45' SOB-44'45-E 331.82' = 2899 SQ. FT. SOD = 3,503 SQ. FT. i OFF LOT CALCULATIONS RIGHT OF WAY = 1382 SQ. FT. 1" = 30' DRIVE APRON = 200 SQ. FT. GRAPHIC SCALEmm PG PUBLIC S/W = 256 SQ. FT. 0 15 30 SOD = 916 SQ. FT. TOTALS AREA = 7,784 SQ. FT. DRIVEWAY = 697 SQ. FT. I SIDEWALK = 294 SQ. FT. SOD = 4.419 SQ. FT. I I� I LOT 14 BLOCK 7 I 'z I ---(RADIAL)(NON—RADIAL)-- b 90 0� (REFERENCE BEARING) 1�0 1 25.00f --- N87.47'o6'E N N87.47 08 E 40_00' — 5' D&AE N I,, — ;a CO D :�.� ::. �2Z of " '. -' �':::::1 t� N Z--I O ,1_.;:,:'.•J" 4.7'� Zem00 .°i �I� cep yy� c ''38i.i uoo�o 8.0' mmµJ.W a �I v I 4.7' wz o . 0Z I D = Co I 51.7' ---- — '� O 20.5' ---- C --, -- 5' D&AE m I r,W ,3 125.00 S86'18 59 o I I ,2942 (RADIAL) (NON—RADIAL)-- ' I I LOT 12 I I BLOCK 7 I I I PREPARED FOR: I LiG�NLCGii gC[d Pit BUILDING SETBACKS FRONT: 20' REAR: 15' SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) SIDE STREET: 15' NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING LEGEND: PLANS PROVIDED BY THE CLIENT. 2. ELEVATIONS ARE BASED ON NAVD 1988 — BUILDING SETBACK UNE PI POINT OF INTERSECTION DATUM. _ PC POINT OF CURVATURE 3. FOR ALL LOTS WHERE SIDE—YARD CENTERLINE PT POINT OF TANGENCY RIGHT OF WAY LINE RP RADIUS POINT SETBACKS ARE LESS THAN 7.50 FEET, A PRC POINT OF REVERSE CURVATURE MINIMUM 5.00 FOOT WIDE DRAINAGE AND PROPOSED ELEVATION FCC POINT OF COMPOUND CURVATURE ACCESS EASEMENT IS REQUIRED PER PASCO TYP TYPICAL COUNTY LAND DEVELOPMENT CODE. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB PER PLAT THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES 0 CONCRETE (C� CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER PB PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND PGS PAGES g/W SIDEWALK OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK Fr. SQUARE FEET D&AE DRAINAGE&ACCESS EASEMENT F.E F.E.M.A FEDERAL EMERGENCY MANAGEMENT AGENCY LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.I.R.M. FLOOD INSURANCE RATE MAP AND IS FOR INFORMATIONAL PURPOSES ONLY. NAVD NORTH AMERICAN VERTICAL DATUM NGVD NATIONAL GEODETIC VERTICAL DATUM THIS IS NOT A SURVEY D&UE DRAINAGE&UTILITY EASEMENT POE PRIVATE DRAINAGE EASEMENT THIS IS A PLOT PLAN ONLY PUE PUBLIC UTIUTY EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M.MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26. 2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE'X',AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION.PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE NORTHERLY LINE OF AShA 3. NOT VALID WITHOUT THE AUTHENTIC LOT 13, BLOCK 7 BEING N87'47'08'E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M E FR I C A N ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED• SURVEYOR AND MAPPER. (FIELD DATE:) �N:mnmimtta! "Digitally signed by James W.Boleman U R V E Y I N G ,LLIAY SCALE: 1"=30 FEET a$ �....A,e ,I DN:cn=James W.Boleman, o=American Sueying&Mapping, A P P I N G INC. Inc., ry ou=HB, APPROVED BY: J9 ;" ---�—email=Jboleman@azmcorporate.com, CERTIFICATION OF AUTHORIZATION NUMBER LBg6393 ^' a _,i=us= _ FOR 180820 LOT 13, 3191 MAGUIRE BOULEVARD, SUITE 200 'k °;A� JOB NO. BLOCK 7 ORLANDO, FLORIDA 32803 �A�roinwuonmw� Date:2019.03.1316:28:26-04'00' FIRM DRAWN BY: DSB WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE PLOT PLAN 03-12-19 KJW 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cali 1828 Elev D 1 ;. Builder Name: DRH Express Homes / Street: pl SI Ve r(p/I(� hG� es VC� Permit Office: Cc, (60 22�J1��f i-lt•rlLs City,State,Zip: Zephyrhil�ts,,PPCC �t( C Permit Number: Owner: ?1 Jurisdiction: - (pll4G Design Location: FL,Tampa 15�-1 County: Pasco(Florida Climate Zone -2)• 1. New construction or existing New(From Plans) 9,-Wall Types(1710.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 t b.Frame-Wood,Adjacent R=11.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A . R= 2 ft 4. Number of Bedrooms 4. d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1828.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned floor area above grade(ft2) 1828 b:N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.NIA R= ft2 11.Ducts R ft2 7. Windows(i 66.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 [� a. U-Factor: Dbl,U=0.34 126.50 ft2 (' SHGC: SHGC=0.31 b. U-Factor: Dbi,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13,Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 fL Area Weighted Average SHGC: 0.317 14.Hot water systems 8. Floor Types (1828.0 sqft.) Insulation Area a.Electric' Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat 1 Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.57 PASS Total Baseline Loads: '61.29 1"" �7 I hereby certify that the plans and specifications covered by Review of the plans andESR' this calculation are in compliance with the Florida Energy specifications'covered by this Code. calculation indicates compliance err, :�, _ ;?��•�� with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: a-t4-w this building will be inspected for compliance with.Section 553.908 i' I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. QD WE 1 . OWNER/AGENT: Q' Wit'`-' BUILDING 16FfIC .DATE: DATE:. s_- - Contpllance requires certification by the air handier unit manufacturer that the air h dler enclosure qualifies as. certified factory-sealecijnaccordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(IT402.4.1.2). - Compliance with a proposed duct leakage Qn r'equires a Duct Leakage Test Report confirming duct leakage�to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for Whole house. 3/14/2019 11:16 AM EnergyGauge®USA Section R405.4.1 Compliant-Software Page 1 of 4 FORM R405-2017 FLO141DA ENERGY EFFICIENCY CODE-FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cali 1828 Elev D• Builder Name: DRH Express'Homes Street: 7iDI� �'I V_ (?�1 VC[ Permit O#fice: City,State,Zip: Zephyrhi s,,- 2 `` Permit Number: Owner: 3354' LV Jurisdiction: Design Location: FL,Tampa- I �j)� County: Pasco(Florida Climate Zone 2}• 1. New construction or existing New(From Plans) ! 9:-Wall Types(1710.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.'Concrete Block-Int lnsul,Exterior R=4.1 1404:00 ft2 b.Frame-Wood,Adjacent R=11.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A = R= ft2 4. Number of Bedrooms 4'. d.N/A R= ft2 5. is this a worst case? No 10.Ceiling Types (1828:0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned.floor.area above grade(ft2) 1828 b:N/A R= f#? Conditioned floor area below grade(ft2) 0 ; c.N/A R= ft2 11.Ducts R ft2 ' N 7. Windows(166.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 p a. U-Factor: Dbl,U=0.34 126.50 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,0=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A W SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump • 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: .0.317 14.Hot water systems 8. Floor Types (1828.0 sgft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b.•Conservation features b.N/A R= ft2 None c.NIA R= ft2 15.Credits Pstat Total Proposed Modified Loads: •60.57 Giass/Float Area: 0.091 p }) Total Baseline Loads: �61.29 _ SS I hereby certify that the plans and specifications covered by Review of the plans and 40 this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance r� ' -: ^,,�t ylk with the Florida Energy Code. nrrf: trr, r;,.= -`''w," 4L C3 PREPARED BY: sPcompleted ;f.. ,,,�.k Before construction is � 1 Cr DATE: 3-N-19 this building will be inspected for compliance With.Section 553.908 . Florida.� 1 hereby certify that this building, as designed,is in compliance Flor Statutes. - •rj.� ,fig ..;. with the Florida Energy Code. Q� OWNER/AGENT: • Q-' '' BUILDING OFFICIAL:' 'DATL: , DATE:. Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as. certified factory-sealed 16accordance with R403.3.2.1. -Compliance requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires art envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).. . - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct teakage�to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for Whole house. 3/14/2019 11:16 AM EnergyGaugeO USA Section.R405.4.1 Compliant Software Page i of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title; Cali 1828 Elev D Bedrooms: 4• Address Type: Lot Information Building Type: User Conditioned Area: 1828 Lot# '1317 Owner Name: Total Stories:-" 1 Block/Subdivislon: Silverado #of Units: 1 Worst Case: No PlatBook: Phase 9 Builder Name: DRH Express Homes Rotate Angle; 270 Street: Permit Office: Cross Ventilation: County:. Pasco Jurisdiction: Whole House Fan: City,State;Zip: Zephyrhilis, Family Type: Single-family FL',, New/Existing: New(From Plans) Comment: Garage L Face W CLIMATE Design Temp Int Design Temp Heating Design Daily Temp J - Design Location ' TMY Site 97.5% 2.5% Winter Summer .Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1828 15848.8 SPACES Number• Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1828 15848.8 Yes 5 4. 1 Yes Yes Yes FLOORS ' # FlocrType Space Perimeter R-Value' Area Tile Wood Carpet i Slab-On-Grade Edge Insulatio Main, 198.6 ft 0 1828 ft2 ---- 0 0.25 0.75 ROOF ; / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type' Materials Area Area' Color Absor. Tested Tested Insul. (deg) 1. Hip Composition shingles 2044 ft2 0 ft2 Dark 0.92 No 0.9 No 0 26.6 ATTIC J # • Type Ventilation Vent Ratio(1 in) , Area RBS IRCC 1 Full attic Vented 300 1828 ft2 Y N CEILING . . # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1828 ft2 0.11 Wood 3/14/2019 11:16 AM EnergyGauge®USA Sectiori R405.4.1 Compliant Software Page 2 of 4 f FORM R405-2017 INPUT.SUMMARY CHECKLIST REPORT WALLS FA Qmf Adjacent Space Cavity Width" Height Sheathing Framing Solar Below WaLTypp 0 1 N=>W Exterior Concrete Block-Int Insul Main 4.0999 19 - 8 8 164.7 ft2 0 0.6 0 _2 E=>N Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 378.4 112 0 0.6 0 _3 S=>E Exterior Concrete Block-Int Insul Main 4.0999 •39 8 8 8 :343.8 f12 0 0.6 0 _4 W=>S Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ft2 0 0.6 0 5 . N=>W Garage Frame-Wood Main- 11 20 0 8 8 - 173.3 ft2 0.23 0.01 0 6 E=>N Garage Frame-Wood Main 11 15 4 8 8 132.9 ft2 0.23 0.01 0 .DOORS '# Omt Door Type Space Storms U-Value Width Height Area Ft 1n Ft In 1 N=>W Insulated Main None .4 3 6 8 20 ft2 ' 2 -N=>W Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). j Wall Overhang . V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>W i Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 i It 0 in 4 ft i in None Exterior 5 2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 3 ft 8 in 0 ft 0 in None Exterior 5 3 E=>N 2 Vinyl Low-E Double Yes 0.34 0.3l N 15.5 ft2 1 ft.0 in 0 ft 9 in None Exterior 5 4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 1 ft 0.1h 0 ft 9 in None Exterior 5 5 S=>E 3 Metal Low-E Double Yes .0.55 0.34 N 40.0 ft2 8 ft 0 in 0 ft 8 in None Exterior 5 6 W=>S 4 Vinyl Low-E Double Yes 0.34 0.31 N 15.5 ft2 1 Ito in. 0 ft 9 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 430.0128 ft2 430.0128 ft2 46.6 ft 8.67 ft 0 INFILTRATION, # Scope Method SLA CFM 50 ELA EgLA, ACH ACH 50 1.. Wholehouse Proposed ACH(50) ,000386 1849 101.51 190.9 .2941 7 HEATINGSYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 28.6 kBtu/hr 1 sys#1 3/14/2019 11:16 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency. Capacity Air Flow SHR, Block Ducts 1 Central Unit/ None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER`SYSTEM # System Type SubType Location. EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None - SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS' / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# �f # Location R-Value Area Location Area Leakage Type Handier ;TOT OUT QN RLF Heat Cool I . 1 Attic 6 356 ft2 Main 40 ft2 Proposed Qn Main cfm 109.7 cfm. 0.06 0.60 1 1• TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolingr Jan Feb r 1 Mar Apr Ma X�Jun Jul Au Se Oct Nov Dec He (?C�Jan EX Feb [X]Mar _ Apr _ E May ]Jun Jul i Aug Sep W Oct Nov �X}Dec Ventin [[[ ]]Jan L[ Feb [[[[XXX]]]Mar Apr [ Ma ]Jun Jul [ Au So Oct HX Nov. 3 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 .12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 .78.. 78 78 Cooling(WEN) AM 78 78 78 78' 78 78 78 78 78 78 _ 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 . 68 68 68 68 68 68 PM'. 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 i) PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS 1• Mass Type Area Thickness Furniture Fraction Space L Default(8 Ibs/s .ft. 0 ft2 oft 0.3 Main Name: Test Rater Signature: Rating Compant: Test Rater Date: 3/14/2019 11:16 AM EnergyGauge@)USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) '12. Ducts, location &insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family . 2. Single-family - b) Return ducts R 6.0 " c)AHU location. Attic/Main 3.No.of units(if multiple-family) 3. 1 4.Number of bedrooms 4. 4 13.Cooling system: Capacity 28.6 a) Split.system SEER 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 1828 d) Room unit/PTAC EER e)Other. 14.0 7.Windows,type and area a) U-f actor:(weighted average) 7a. 0.390 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.317 14.Heating system: Capacity 28.6 c)Area - 7c. 16&5- a)Split system heat pump HSPF b) Single package heat pump.HSPF ; 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace,natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.20 9. Floor type,insulation level- a)Slab-on-grade(R--Value) 9a. 0.0 b}Wood,raised(R-value) 9b.. 15.Water heating system c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10:Wall type and insulation: c)Gas fired, LPG EF A.Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 1.OA2. 4.1 0 Heat recovery.•unit HeatRec% B.Adjacent: g)Other 1.Wood frame(insulation R-value) 1081. 11.0 .2.Masonry(Insulation R-value) 10132. 16.HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fan's a) Under attic 11 a.' 30.0 b)Cross ventilation No b)Single assembly 11b. c)Whole house fan No c)Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier,installed 11 d. Yes e)Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code,Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code,Energy Conservation,through the above energy - saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: =J�J.Att� It Date: �J �� 1� Address of New Home: St lyeyYAc, Rzwl' t)IVC�, City/FL Zip: Zephyrhills, FL 3/14/2019 11:16:27 AM EnergyGaugeO USA 6.0.02-RaRes2017 FBC 6th Edition(2017)Compliant Software Page i of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive-and ERi Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. . SECTION R401 GENERAL . R401.3 Energy Performance Level(EPL)display card(Mandatory).'The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law . (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display,card contains information indicating the energy performance level and efficiencies of components " installed in a dwelling unit.The building official shall Verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building-.A copy of the EPL display card can be found in Appendix RD.' rj R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage In accordance with the requirements of Sections R402:4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4,1 Building thermal enveto-pbe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as appiicabie'to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones i and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSIIRESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).-Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as'set forth in Section 489.105(3)(f),(g)or(i)or. an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope.of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers.shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test;shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. 0 R402.4.2 Fireplaces. 'New wood-buming fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors.on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors ridmore than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400,or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed'and labeled by the manufacturer. - Exception: Site-built windows,skylights and doors. •1 r,Ann EnerovGaune0 USA -FSC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel-burning appliances. in Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel.burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed•and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls;floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and-any water-fines and ducts in the room insulated in accordance with Section R403'.The combustion air duct shall-be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1008 of the Florida Building Code',Residential. ❑R402.4.5'Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283,at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ' SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric4esistanee heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,'filter boxes and building cavities that form the primary air containment passageways for air*distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.- Duct tightness shall be verified by testing in accordance with ANSIMESNEVICG 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(1),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3..' ❑ R403.3.2.1 Sealed air handler. Air handlersshall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturers air handler enclosure.Registers shall be taped or otherwise seated during the test. Exceptions: 1: A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. . A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑R403.3.5 Building cavities(Mandatory): Building framing cavities shall not be used as ducts.or plenums. ❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55'F(13°C)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping Insulation. Piping insulation exposed to weather shall be protected from damage,including that . caused by sunlight,moisture',equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted, ❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall'be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return -' ❑ pipe shall be a dedicate.d'retum pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot-water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no'demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or uL 515.Controls for such systems - shall automatically adjust the energy input to the heat tracing to maintain the.desired water temperature in the piping iri accbrdance With the times when heated water is used in the occupancy. ' �n .�r a:a mni 7�t mm�tiant Gnftware Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank.. R403.5.6 Water heater efficiencies(Mandatory). R403.5:6.1.1 Automatic.controls. Service water-heating-systems shall be equipped with automatic temperature controls capable . of adjustment,from the lowest-to the highest acceptable temperature settings for.the intended use-The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60*C). Fi R403.5.6.1.2 Shut down. A separate switch or,a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burners)of combustion types of service water-heating systems to be turned off., R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy.Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water heating systems.. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy denier Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems.should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true_south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the,. Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,.Infiltration or Mechanical means.Outdoor air intakes and exhausts.'shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole=house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, v" crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3• If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,of R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment'sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a._ AIRFLOW RATE MAXIMU (CFM) (CFM/WATT) (CFM) Range hoods _ Any. 2.8 cfm/watt Any In-line fan Any', 2.8 cfm/watt Any Bathroom,utility room . 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 L/mIn. a. When tested in accordance with HVI Standard 916 3/14/2019 11:16 AM EnergyGaugeO USA -'FBC 6th-Edition(2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product fines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load.. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded.performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),"the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted far return side gains if the return duci(s)is installed in an unconditioned space.' Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80,percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice, R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design, requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space coaling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide coaling or heatirig to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50'F(10°C),and no. precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2.: Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. ❑ R403.i0.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped-with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce.heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat"pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-'and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum.thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when.tested in accordance with ANSI Z 21.56:Pool - heaters fired by natural or LP gas shall not have continuously burning pilot lights. -•• . -- ,,-,r ••._ _ . .,r ., n ac n _r-P(..Rth Priifnn(9n17) Compliant Software Page 4 of 6 ❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance" with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatory)he energy consumption of electric-powered portable spas shall be controlled by the requirements"of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems-shall not have continuously burning pilot lights. " ^ia++^^+^ +•a^ ARa Cn^.n,it o,natwt[LQA _FRC'.Rth Friitinn t?n171 C:omnliant Software Page 5 of 5 2017- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA' TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: W Owner: Jurisdiction: • x Design Location: :FL,Tampa c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. . not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation*and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed.. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be, shall be insulated by completely filling the cavity sealed, with a material having a thermal resistance of R-3 'Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,-skylights The space between window/door jambs and framing;and and doors. skylights and framing shall be sealed. . Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall_be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side. floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class 1 vapor retarder with overlapping joints taped. , shall be permanently attached to the crawlspace Shafts,penetrations. Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in.narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 9s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures4ristalled in the building shall be sealed.to the drywall. thermal envelope shall be airtight.and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on Installation readily conforms to available space shall extend behind pipina and wiring. Shower/tub. The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not.be used to fill voids a.In addition,inspection of log walls shall be in accordance with the provisions of iCC 400, 3/14/2019 11:16 AM EnergyGaugeO USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 l Envelope.' nvelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 ,Florida Building Code, Energy Conservation, 6th..Edition - Jurisdiction: Permit#: Y tw — d: „i •:Ja o at Pill, - - Builder: DRH Express Homes Community: Lot:- 13/7 Address: City: Zephyrhills State: .FL %-Zip: ' "r:• <..., 1 e k eS 'Resu :5` .. assrn Yrr.`esu is? iusf.rriee ether'-th !rs. 0, e rmaice ;P escri"fi%e"or,`ERJMetho PRE CR12 E METHtOD=T~`build`' o 'd ''iny unit'sfiall "e e'ted''lrid erified a h ui n 'irle It 'e:r Elio'ezce diri`_7 S V he, m wail t b t s .a s a `a ,a a s ate;o t. a ',3. _ _ .9:. ..;2.,,>.9s,;..C." .-:.p': "';.Y=•- is>.. 9�' ; g_.`....J.- g Bch a r,`.ltouf':at:a-'r ure,.of;027nch�w:' '.'50 ,ascal n,- Im t 1.. ,,"_�'� - _ _ _ •2 _ _ xE E-.iir: E : b `ild`' i al[.E'ested,and:ver5ei9 as 'v` r'I"`'`"e"r'`q_ _--* ,exce di '' "P RFORMANC EIRI�M Tt10 �The`kiu in oi:clwelln :unit=sh b .t I ha ig �an`ai eaka at of n ' °fherselected AEH 50':vatiie as:showri on Form;R4i)5=2i11:7'Peiformance:or,R406-201:7:'ERt >s_ecfidn_'Iabele `irrfiI_tratior_i'suf�=secUori.`AGH50 . r, c;> :o a,oE fi-2:' GH 0 s yec''ed;o 'Form`-`0520 lie Cal Perf rmaiic r R40 017E 7.000 A 5 �fr n LR4 i•7:E RI': i.: et' x 60 15849 — Method for calculating building volume: CFM(50) Building Volume ACH(50) - Q Retrieved from architectural plans PASS i Code software calculated, When ACH(50) is less than 3, Mechanical Ventilation installation O Field-measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or.an approved third party.A written report of the results of the test shall be signed by the partyconducting the test and provided to thecode official..Testing shall be performed,at any time after creation of all penetrations of the building thermal envelope.. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and.sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. nth"- - t.• yt:` - :'„1::":, Testm' Company; - - s Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. .'- Signature of Tester: Date of Test: Printed Name of Tester; License/Certification#: . Issuing Authority: 3/14/2019 11:16:43 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Duct.Leakage.Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida.Building Code; Energy Conservation, 6th Edition' Jurisdiction: Permit#: j C..i5'�liifo ET'!�•'1IOt3<.' - r„ , , Builder: DRH Express Homes. Community: Lot: 13/7 Address: City: Zephyrhills State: FL Zip:. C_''' !1'—'�Y' h: =:Performance%ERI Met. od. , D"uctt:eaka <;e`Tes#>Resalt�s;;-�� PrescrlE�tive-,Nlet od:;� ��' _ 6 s� •L:t t: rr�4'i•"��' System 1 cfm25 , �,"Q Prescrtptzve Method `tcfm25.(Total),. •s V t T`''•"alif"�:s`"sukistan ial( 'leak;free"Qn`7etal mcast;b'e?less;t[ian'off,, ' System 2 cfm25 :.oaq� ..X;a ;y-,,..: - _:..,.:-• . e tialto_`0:04sf air_fiarteflr:ciiit;is Installeci:lf:a�rtiantller;uriit'=is rift=.- ; =i `lied`S+nTof lmustaeTess}than or-°e'<ual;to0:03:This•testiri System 3 cfm25 nsta ,sQ. a - ,•, :q,. ',iiaefto'd ii�ieets`;thereY'tiiTerri.ents��m,a'ccordance�with Section:R;4.03�3:3�'��� ,�, ""i'ti� ntlerunitins�altecJ^^�iirin�`�festiil' �.l'ES �<of;+� Sum of any cfm25' f 1 cfm25 -Total o a I C re `nce`ERIMetho'd `Perfo. mfa_ / 4-. - E ter than the` :.�-T:o��ua(i "•,usin '�ttii�imetFiod�:Qnmust�not`beg ea "ct l' 'ka e'Qrrs ecifiFedson Foftn 05'2Q1;7 or.-R406:=201r7 1828 = Qn ,prr%poseti::dp ea -,g, .p4_ ., _.,.. ,r.. "'P. ' "T... _.... fall 'Total Conditioned Total 0 Square Footage - - - _ _-systems squ e F g "= q� ecifred=on:For- R4(1 =2t717 :Ceakage sType'.selectetl'on<Forrrr :' G?_ ,sp.. a1c=or-R406=,2017=::?Ener Calc ar R4Q6�201_?;' 6, PASS FAIL ' Proposed On4 r;^`0.06 >, Duct tightness shall be verified by testing in accordance with ANSURESNET/ICC380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes. tail: 9 �kf.. 3re� hr, Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above,either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority. 3/14/2019.11:16:49 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Manual S Com "liance'Re ort Job' - wrightsoft® p • Date:. Entire House By: Progressive Air Systems, Inc Plan: laze Call 5907'Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399"• License:CA'C033669 PrQjectJhf6fmafion For: DR Horton Lot 13 Blk 7 Silverado, Zephyrhills, FL PilJolin. fulpMelit Design Conditions - Outdoor design DB: 91.2°F Sensible gain:, 20971 Btuh Entering coil DB: 75.8°F Outdoor.design WB: 77.1 OF Latent gain: 3647 Btuh Entering coil WB: 62.90F Indoor design DB: 75.0°F Total gain:_... 24618 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP -Manufacturer: Carrier Model: CH14NB030+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity:. 23045. Btuh 1100%of load Latent capacity: 4228 Btuh 116%of load Total capacity:, 27273 Btuh 111%of load SHR: '84% . • • • Design Conditions. Outdoor design DB:' 40.0°F Heat loss: 21992 Btuh Ertering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions' Equipment type: ..Split ASHP Manufacturer: Carrier Model: CH14NB030+FB4CNP030 Actual airflow: 1000 cfm Output capacity: 25616 Btuh 116%of load Capacity balance: 33 OF. Supplemental heat required:: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: .6.6 kW 1020%of load Temp. rise: .20 OF Meets are all requirements of ACCA Manual S." 1 Wrl hlkSoft' 2019-Mar-1411:16:56' 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 House Front.faces: W Load Short Form "Job: ; wlrightsoft - . Date:' Entire House By: Progressive Air Systems, Inc Plan: ysascar 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669. Project • • For: DR Horton Lot 13 8I0 Silverado, 2ephyrhills, FL Desi• • • Htg Clg Infiltration Outside db(OF) 40 91 . Method Simplified Inside db(OF) 70 75 Construction quality Semi-tight Design TD (°F) 30 16" Fireplaces . 0 Daily range - L Inside.humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER. Model CH14NBO30 Cond CH14NBO30 AHRI ref Cail FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling .22500 Btuh Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.045 -cfm/Btuh Air flow.factor 0.048 cfm/Btuh Static pressure 0.45 in H2O Static pressure 0.45 in H2O Space thermostat Load sensible heat ratio. 0.85 Capacity balance point=33 OF Backup: Input=7 kW, —Output=22477 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load' Htg AVF Clg AVF (ft2) (Btuh) (Btuh) '(cfm) (cfm) m.bed 194 3361 3343 153 159 living 252 3018 3872 137 - 185 kitchen/dining 367 4532 4197 206 200 bed 3 149 1484 1162 67 55 bath 2 55 634 298 29 14 bed 2 158 3573 3517 162 168- wc 21 0 0 0 0 m bath 114 1350 712 61 34 wic 66 87 129 4 6 laundry. 39 45 681 2 32 bed 4 -169 1976 1407' 90 67 a/c 18 0 0 0 0 .foyer : 218 _ 1934 1654 88. 79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrl fE 20i9-Mar-14 I� �htso � Right-Soite�Universal 2017 17.0.21 RSU25554 - '. Page 1 ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Cala=MJ8 House Front faces: W Entire House d' 1820 21992 20071 1000 1000 Other equip loads 0. 0. Equip- 1.00 RSM 20971 Latent cooling 3647 TOTALS 1820 21992 24618 1000 10Q0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed-. wri htsoftF 2019-Mar-1411:16:56 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc MJB. House Front faces: W ProjectSummary Job:: - - wrightsoft® Entire House by:. Progressive Air Systems; Inc Plan: 1828Ca1i 5907 Dasher Of,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Prooect Information For: DR-Horton Lot 13 Blk 7 Silverado, Zephyrhills, FL Notes: Didsign Information Weather: Tampa Intl AP, FL, US Winter. Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF. Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb. Heating Summary Sensible Cooling Equipment Load Sizing Structure . 17435 Btuh Structure 15417 Btuh Ducts 4558 Btuh Ducts 5554 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm). 0 Btuh, none Humidification 0 Btuh - Blower. ) 0 Bfuh Piping 0 Btuh Equipment load 21992 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load . 20971 Btdh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2347 Btuh Ducts 1300 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1820 1820 Equipment latent load 3647. Btuh Volume (ft3) 15855 15855 Air changes/hour 0.26 0.14 Equipment total load 24618 Btuh Equiv.AVF(cfm) 69 37 Req.total capacity at 0.75 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO30 Cond CH14NBO30 AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling .22500 Btuh' Heating output. 29600 Btuh @ 47OF Latent cooling 7500 Btuh Temperature rise . 271 OF Total cooling . 30000 -Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.045-.cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.45 in H20, Static pressure 0.45 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=33 OF Backup: Input=7 kW, Output:=22477 Btuh, 100-AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htSOft" 2019-Mar-1411:16:56 g Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 -House Front faces: W FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative-(Performance) Method. Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the . residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report.that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include.a summary page indicating home address a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page)and an input summary checklist that can be used for field verification (usually four pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual S'or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO for,the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) L ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage, then a completed Form R405 Duct Leakage Test Report(usually one page) 3/14/2019 11:16:15 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 PASCO COUNTY ReoelptDatw. 4/1112016 112:191 aim CONSTRUCTION SERVICES Receipt Number 111902106 PASC O BUILDING 8731 Citizens Drive COUNTY FLORIDA. y Suite 230 OPEN SPAM.!LIMANI'PUM. New Port Richey,FL 34654 727-847-8126 NOT A PERMIT Paid By Check# CC Auth# Cashier ID Worhstation, Check 992065 SLEBLANC BCCCP06W Fee Descriptign Arnt Paid impact Fee Residential Solid Waste Single Family 12.74 Total Payments: 12.74 Pavor Address PhonR DR Horton, Inc. 1341 Horton Circle Arlington TX 76011 Comments; City of Zephyrhiils Solid Waste 7018 Silverado Ranch Blvd. 1 05 26 210100 00700 0130 while yovwm be paylax your blit with Pasco County OulldInGDrutructlan services,the full amount of the credit carder e-checkfass.NoT shown above,Is collected by First SlIllng payment services. mymport,-,#epcdslIPASCOPRODIPASCOICustomer Receipt vld.fpt Print Date: 10/21/2019 Page 1 of 1