HomeMy WebLinkAbout19-21512 CITY OF ZEPHYRHILLS •` 5335-8TH STREET (813)780-0020 21512 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 21512 Address: 6336 SILVER OAKS DR Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVER OAKS Est. Value: Parcel Number: 03-26-21-0120-00000-0180 Improv. Cost: 1,257.00 OWNER INFORMATION Date Issued: 7/18/2019 Name: BAINTER ELIZABETH Total Fees: 75.00 Address: 6336 SILVER OAKS DR Amount Paid: 75.00 ZEPHYRHILLS FL 33542-4812 Date Paid: 7/18/2019 Phone: 309-338-0232 Work Desc: REPLACE 2 WINDOWS S/S CONTRACTORS APPLICATION FEES WINDOW WORLD OF TAMPA BAY LLC BUILDING FEE 75.00 Ins ections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ' O Z `> SIGNATURE PERMIT OFFI R IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION ALL FOR INSPECTION B HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting / 7X. Owner's Riame. /y,i %A/ -i Owner Phone Number �` � t, V Far—i Owner`s Address 3 :'�.,9Ig9�l�J�SPh�jjiJ!'S I~/3��" Owner Phone Number Fee Simple Titleholder.Name �.. Owner Phone Number �— Fee Simple Titleholder Address p l08 ADDRESS'' �:ftp� A9 :t iC3 .i33✓5+�.� '}a_ GGS LOT# 0 ' SUBDIVISION S PARCEL ID# lJ - - %2rt�o•o�r�i3O==d! gp =:== =� (OBTAINED"FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT, C-� SIGN 0 Q DEMOLISH INSTALL 8 REPAIR PROPOSED USE SFR 0 COMM „, � _ OTHER'. TYPE OF CONSTRUCTION ' 0 BLOCK' 0 FRAME STEEL 0. DESCRIPTION OF WORK. ,. G -j' �� f'�iL:Ii2 2 !_ �-�_''v!- A ? •: ...... BUILDING SIZE SO FOOTAGE C� HEIGHT ®BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE Q "'' PROGRESS ENERGY Q W.R.E.C. [PLUMBING, $ Z IS =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION: " =GAS Q ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS, FLOOD ZONE AREA DYES NO BUILDER COMPANY SIGNATURE REGISTERED I Y! N FEE CURREh Y/N �ar�� Azrbvd� a� Address License ELECTRICIAN. COMPANY SIGNATURE REGISTERED Y/ N 'FEE CURRE+ Y J N Address License# F I PLUMBER COMPANY ' SIGNATURE REGISTERED Y/ N FEE CURREN Y l N Address License# 77 MECHANICAL x COMPANY" SIGNATURE ." REGISTERED,, Y/ N I FEE CURREh Address License# ! OTHER., COMPANY SIGNATURE REGISTERED Y/-N FEE CURREit Address License# l•-1 1 1 ! 1 CPI"! 1 1•I i I i 1 1 l i i ! 1 t ! l i i l ! 1 1 ! 1'! 1 i 1 1 1 1 !' 1':1'.. RESIDENTIAL— Attach(2)�Plot Plans;-(2),sets of Building-Plans;(1).set-of.Energy Forms;.R-O-W Permit'for-new_r_,onstriiction, Minimum ten'(10)working days after submittal date.-Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,. Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects _ COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.-Required ansite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpste'r.Site Work Permit for'all new"ptofects.All commercial requirements must meet,compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ' PROPERTY SURVEY required for all NEW construction. ■"■ r ■ ■ ■.■-■ . . ■ ■ . ■ ■ Directions; Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ' Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING . (copy of contract required) Reroofs if shingles Sewers Service:Upgrades A/C Fences(Plat/Survey/Footage)- Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with,any applicable deed restrictions. - UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,-they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required,by law,_both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the.Pasco County Building Inspection Division—Licensing Section at 727-847- 8009.- -Furthermore,- if the owner has hired a contractor or contractors, he is advised to have the contractor(s)-sign portions of the "contractor Block"-of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is_not properly licensed and is not entitled to permitting privileges,in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, 'as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release; the fees must be paid prior,-to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in-accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide prepared by the-Florida.Department of Agriculture and.Consumer Affairs., If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement.' CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application-is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and.that all work will be performed to meet standards of all laws, regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction:" I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such`agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland`Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment: Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - _ US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of:fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is 'to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill 'material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill,material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent-properties, the owner may be cited for violating the conditions.of the building permit issued under the attached permit application, for lots less than one.(1) acre which:are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the-owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate-permit maybe required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or.other installations not specifically included in the-application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every-permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit is -or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from-the Building Official•for.a.period not to exceed ninety (90) days and will demonstrate. justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER:, YOUR-FAILURE TO RECORD_A_NOTICE OF COMMENCEMENT MAY RESULT IN YOUR _ PAYING TWICE FOR IMPROVEMENTS TO YOUR-PROPERTY. IF YOU INTEND TO-OBTAIN FINANCING, CONSULT— _• WITH•YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT: FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CON_TRACTORt-----•— Subscribed and sworn to(or affirmed)before.me this Subscribed and,sworri to=(or affirmed)_before_me,this: =� by — by Who is/are personally known to me or has/have produced Who is/are personally known to me or'tias/tiave produced - as identification. as Wen fification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name,of Notary typed,printed or stamped j I - Window and Sliding TM -' le'"o I - v�� °,Tempo �� Patio Door Contract SCcstf of age veae Showroom 10741-C Endeavour Way FL Contracor's License#SCC131151663 Location., Pinellas Park, FL 33777 j 1.866.WIND.189 866-946-3189 1 E-MAIL: _Units Completed- Windows,_Doors Remainin ! Name _2 r Home Phone .G� Address G Customer ID#: 3 [7 Work Phone City/St/Zip _ FL Cell Phone Windows Options ! I Series Model# Z Half Screen $10 E P Double Hung - IUp To 114 U11 Full Screen $22 11 1 6000 DH WeldlWeld 0501 HP $285 �_Double Locks(>30"wide) $9 P 8000 DH WeldirWeld 8401 $250 _�Argon Gas $21 E SP 'L— 7700 DH WelclMeld 7701 $200 V&c> Foam Insulation Wrap $12 ESP 6000&8000 Series DH>114 UI Add $35 DP Rated Glass N/C I C. Other Styles Model 0 Beige or Tan or Clay Vinyl Color $37 ! Picture Window $329 Wood Grain-Inside Surface $90 ! 2 Lite Slider-(Up To 114 U.I.) $329 Exterior Color w/Full Screen $175 i 2 Lite Slider-(115 To 138 U.1.) $389 Z Low-E Elite Glass(App-.21) $65 ESP 2 Lite Slider-(�13e U.I.) $479 Tempered Glass Per Sq Ft ONE Side $8 Casement/Awning $329 Obscure Glass Sq.Ft $6 3 Lite Slider-(Up To 114 W.) $520 Tinted-Grey or Bronze Sq.Ft $6 3 Lite Slider-(115 To 13e U.I.) $580 Colonial/Contoured Grids $47 j 3 Lite Slider-(>13e U.I.) $670 Odel/Cottage Style 60/40 $26 3100/6000 Series Add $40 Scaffolding-Per Day $400 I Specialty Windows Boom Lift-Per Day $800 $ $ I $ L Energy Star Pack-ESP $79 J $ Additional Labor Charges $ 2-Lite Slider Inst. >114U.1.Add $40 _ Remove Steel Window $40 Window World continues to maintain the GoodrAli Housekeeping seal of approval,and all our . 3-Lite Slider Inst.Add $60 windows are Gold label certified, ensuring Installation-Standard $150 g our window systems are of the highest quality. All of our 'oL01 -4 Recess Opening $50 A windows have Double Strength Glass and DP rated glass. LCBEt.. Install Custom Int/Ext Trim $40 PRE 1978 BUILT HOMES(Federal Lead Containment La ) Additional Story Charge-Per Floor $10 ! My Home Was Built In The Year Initials: Install Exterior Capping $125 j DOORS Bay Window Finish&Trim $300 j 51 i Series Patio Door 5'-51 i5.6'8" $950 Header Flashing(Req.for Siding) $12 51 i Series Patio Door 6'-51i6-6'8" $1,011 Repair Sill OR Jamb Per Ft. $15 51i Series Patio Door 8'-51 i8-6'8" $1,195 Structural Mullion for multi-unit $90 Low-E Elite Glass w/Argon Per panel $90 Replace Interior Marble Sill $110 i Grids-Patio Door Per Panel $60 Replace Exterior Concrete Sill $335 Beige-Patio Doors Per Panel $75 Install Pocket Door $800 Sliding Door Frame Installation $250 Maintenance Agreement - #of Windows Panel Installation Add-PP $85 $ 8'Tail Panel Installation Add-PP $25 $_ $ $ i The buyer Is responsible for: Window World agrees to install windows and doors You the buyer may cancel this •Securing,identifying,and completing all HOA and Sub as noted above and on the attached order form and to transaction at any time prior to division rules,requirements,and applications. perform other services as specified above for the price midnight of the third business day •Removal and re-Installation of any existing security quoted on this form.No other promises, expressed or after the date of this transaction. system,burglar bars,A/C units,window coverings,and/or implied,are made except those expressed in writing Notice of cancellation must be in obstructions prior to installation. on this agreement. writing postmarked no later than j Additional charges for removing Items are at the following rates:A/C unit-$50;Curtains/Blinds-$25/Window;Fumiture- If Window World seeks legal counsel to enforce midnight of the following third $1o/Item;shutters-$50 each. obligations under this contract,Customer agrees to business day. pay reasonable attorneys fees and costs. INITIA2:w INITIALS: No extra Vyork if not in wri6nul Customer Agrees to the terms of payment as follows:_ Total List Price $ �f i Trip Charge and Administrative/Site Setup Fee-$100 $ 10 .00 I 1 Site Specific Engineering)Fee$200 $ j Fire Marshall Plan Review(St.Pete Only)$125 $ i $ I,i'-O Permit+$149 Acquisition Fee$ 2- Total Amount $ CK# Custom Order Deposit 50% $ Z Balance Paid to Installer upon Completion $ vNnoow woo Amount Financed $ iN Mr v ■tea.. Loan Approval# -\ Round Up&Contribute to St Jude$ o G a 3 6 03 Os=2_2_ C la'KN VISA MEX DISC Exp.Date c Code, Emp.# Estimator Date Owner Dat KM1rtlo.e WOM1fdTanpo aaY.LLC Nde Wuamv Woda,Woddd W4da» l ' vmuacaey-odomar Yela„c,ff.C Me' (Tuner Dat i ! ii 6, Florida Building Code®mine Page 1 of 3 7701 Business & Professional Regulation: 11F I BCIS Home Log In User Registration Hot Topics 1 Submit Surcharge Stats&Facts ! Publications j Contact Us ! BCIS Site Map'j Links Search . FI nda �D� Product Approval ' ra USER:Public User; n YL� WAR n ' OD— S�t�iCL QiV1Fa,1 {,i, Product Approval Menu>Product or Application Search>Application List>Application Detail NATIONAL ll: r��111 EJ R�I t��®tI U y'7H L9R�+ry��' g VA ��``99 ;J 1 11 V tAl ALE d6 c®® trjV� FL# FLIS819-R10 ��®'SHE CITY OF ��H D�' � Application Type Revision CEO Rd-IldL,9 Code Version 2017 Application Status Approved REVIEW D;gTdUL 12 2019 Comments TM Archived ❑ p OP ZEPHyLANRHIL p t (/�//� Product Manufacturer Wincore Window Company,LLC E �/III�IERe_..11 Address/Phone/Email 250 Staunton Avenue Parkersburg,WV 26104 (304)485-7460 Ext228 mreed@wincorewindows.com i Authorized Signature Vivian Wright rickw@rwbldgconsultdnts.com Technical Representative Mike Reed Address/Phone/Email 250 Staunton Turnpike Parkersburg,WV 26104 (304)485-7460 Ext228 mreed@wincorewindows.com I Quality Assurance Representative Mike Reed Address/Phone/Email 250 Staunton Turnpike Parkersburg,WV 26104 (304)485-7460 Ext228 mreed@wincorewindows.com Category Windows Subcategory Double Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Li Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report i Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J.King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15819 RSO COI (b)Certificate of Independence ocif I I Referenced Standard and Year(of Standard) Standard Year AAMA/W DMA/CSA 101/I.S.2/A440 2008 AAMA/W DMA/CSA101/I.S.2/A440 2005 'ASTM E 1300 2004 ' ASTM E1886 2005 ASTM E1996 2006 TAS 201,202,203 1994 Equivalence of Product Standards Certified By https://floriddbuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDqueci 1%2bT''71%2fF1... 5/18/2019 Florida Building Code Online Page 2 of 3 Sections from the,Code Product Approval Method Method 1 Option D Date Submitted 02/20/2019 Date Validated 02/20/2019 Date Pending FBC,Approval 03/01/2019 Date Approved 04/16/2019 Summary of Products FL.#A Model,.Number or Name Description 15819.1 a.8400 Series Vinyl Double Hung Extruded PVC Double Hung Window with"Non-Impact" Window Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 R10 II (b)Inst 15819.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent.7hird Party:Yes Design Pressure:N/A Evaluation.Reports Other:See INST 15819.1 for Design Pressure Ratings,any FL15819 RIO AE (a)Eval 15819.1.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. i 15819.2 " b.8800 Series Vinyl Double Hung Extruded PVC Double Hung Window with"Impact"Insulated Window Glass I Limits of Use Installation Instructions Approved.for use in HVHZ:No FLIS819 RIO II (b)Inst 15819.2.odf Approved for use outside HVHZ:Yes Verified By:.Lyndon F.Schmidt,P.E.43409 I Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A.. Evaluation Reports_ Other:See INST 15819.2 for Design Pressure Ratings,any FL15819 RIO AE (b)Eva[ 15819.2.odf additional use limitations,-installation instructions and product Created by Independent Third Party:Yes particulars. i 15819.3 c.8800 Series"HVHZ"Vinyl Double Extruded PVC Double Hung Window with"Impact"Insulated "Hung Window Glass Limits of Use : Installation Instructions Approved for use.in HVHZ:Yes FL15819 RIO II (c)Inst 15819.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation'Reports Other:See INST 15819.3 for Design Pressure Ratings,any FL15819 R10 AE (b)Eval 15819.3.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. ' 11I 15819.4 d.400 Series Vinyl Double Hung Extruded PVC Double Hung Window with Nailing Fin-"Non- I Window Impact"Insulated Glass I Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 RIO II (a)Inst 15819.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409. Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports j Other:See INST 15819.4,for Design Pressure Ratings,any FL15619 RIO AE (a)Eva]15819.4.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes j particulars. 15819.5 e. 500 Series Vinyl Double Hung Extruded PVC Double Hung Window with Nailing Fin and Window Integral"Y'Channel-"Non-Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in.HVHZ:No FL15819 RIO II (a)Inst 15819.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409. Impact Resistant:No' Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.5 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.5.odf additional use limitations,installation instructions and product Created by.IndependentThird Party-Yes. . particulars. I 158.19.6 f.5400/54005 Series Vinyl Double Extruded PVC Double Hung Window with"Non-Impact" Hung Window Insulated Glass(Double Strength Glass with Reinforced Sash) I Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 RIO II (a)Inst 15819.6.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409. https://floridabuilding.org/pr/pr ap-P dtl.aspx?param=wGEVXOwtDciuea1%2bT71%2fF'1.:. 5/18/2019 i Florida Building_Code Online Page 3 of 3 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.6 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.6.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.7 g.5400/5400S Series Vinyl Double Extruded PVC Double Hung Window with"Non-Impact" Hung Window Insulated Glass(Single,Strength Glass with non-reinforced . Sash) Limits of Use Installation Instructions' Approved:for use in HVHZ:No FL15819 R10 II (a)Inst 15819.7.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.7 for Design Pressure Ratings,any FL15819 R10.AE (a)Eva] 15819.7.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.8 h.7700/9000 Series Vinyl Double Extruded PVC Double Hung Window with"Non-Impact" Hung Window Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 R10 II (a)Inst 15819.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes. Design Pressure:N/A Evaluation Reports Other:See INST 15819.8 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.8.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.9 i.7700/9000 Series Vinyl Double Extruded PVC Double Hung Window(Reinforced Sash)with Hung Window "Non-Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 R10 II (a)Inst 15819.9.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819,9 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.9.odf additional use limitations,installation instructions and product Created.by Independent Third Party:Yes particulars. . Bacl< Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement 7 Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please - clicic here. Product Approval Accepts: Credit Card Safe i I I i 1 i I 1 j i i httns://floridabuildinL.oriz/i)r/nr abn dtl.asbx?baram=wGEVXOwtDouea1%2bT71%2fF1:.. 5/18/2019 i R W R W Building Consultants,.Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 819.8 Product Evaluation Report Repori No..- FL-15 l 017 Product Sub Category Manufacturer Product Name Category Wincore Window Company,LLC. 7700 19000 Series Windows Double Hung 250 Staunton Turnpike Vinyl Double Hung Parkersburg,WV 26104 Window "Non-Impact" scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID# .1998)for Wincore Window Company, LLC. based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing:or distributing the product or in any other entity involved in the approval process of the product named herein. . Limitations: 1. This product has beeneyaluated and is in compliance with the 6th Edition (2017) Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing orstucco. 3. When,used in areas requiring wind.borne debris protection this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609A.2&R301.2.1.2. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. .. 5. Site conditions that deviate from the details of drawing.FL-15819.8 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15819.8•for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02801070. AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab,,lnc. V.K.Wright j TEL 02801071 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright j 2.'Drawing No. Prepared by Signed&Sealed by No.FL-15819.8 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. 3. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#98'13) Lyndon F.Schmidt, P.E. ASTM.E1300 Glass Load Lyndon F. Schmidt, P.E. 4. Quality Assurance. . Certificate of Participation issued by National Accreditation and Management Institute,certifying that Wincore Window Company, LLC.is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide.53. No " •rPtr ��L f , 3' 0 Z-u_ i �'r�G9P�Of1.L'Joc�� Lyndon F.Schmidt,P.E. FL PE No.43409 7/19/20.17 Sheet 1 of 1 i i 52"MAX FRAME WIDTH. ���� ............ 4 1 I rr ru 45"MAX D.L.O.WIDTH , O CS 250 Staunton Turnpike,Parkersburg,WV 26104 1 o M z oM•: m a cg xz,1 7700 / 9900 Series � isCOA D d c ¢ ° md0. My! Double Hung � � � "XVTI / E oZ Window "NON-IMPACT" w �3 q¢ c oz �x 8(D s 48 GENERAL MOTES m O \o N W v CY Oq ¢ ¢Of 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements /Jl g > a excluding the"High Velocity Hurricane Zone"(HVHZ). a a 2. Product anchors shall be as listed and spaced as shown on details. j Anchor embedment to base material shall be beyond wall dressing .MAX. Max. r;c4ss,, DESIGN PRESSURE tPsr MAx.. MAX. GLASS DESIGN PRESSURE(PSI) 4 or stucco. FRAME 'D.LO, .. FRAME D:LO. DIMENSIGCt., DIMENSION.... POSITIVE FIE.AIE DIMENSION- DIMENSION - 'TYPE i. POStrNE NEGA'DVE:. 1z ^ 3. When used in areas requiring wind borne debris protection this 32.0°x SB.D" 25.0"X 24.75' G1,G2 +55.0 -55.0 36.0"x 64.0" 29.0"x 27.75" G1,G2 +40.0 -40.0 N N product is required to be protected with an impact resistant covering z a that complies with FBC Sections 1609.1.2&R301.2.1.2. 52.9"x 40.0" 45.0^x 15.75^ 'GI,G2 +45.0 45.0 32.a"x 70.o 2&W X 30.76' G1;G2 +40.0 -ao in 48.0"X 42.0° at.0"x 16.75" G1,G2 +q5.0 -q5.0 52.0"x SO.o" A5.0"x 20.75" G1,Ga +35.0 -35.0 W 4. For 2x stud framing construction,anchoring of these units shall be the o a W x some as that shown for 2x buck masonry construction. 44.0"x46.o" 37,0^X 18.75° Gt,G2 +45.0 45.0 4B.a"X s4.0" 41.0"xz2.7s G1,G2 +35.0 -35.0 ?W 5. Site conditions that deviate from the details of this drawing require 40.0°x 52.0" 33.0"X 21.75' G1,G2 +45.0 -45.0 44.0"X 60.0" 37.0"X 25.75" G1,G2 +35.0 -35.0 a 6 15 a further engineering analysis by a licensed engineer or registered 36.o"x56.0^ 29.D"x23.75° Gi;G2 +45.0 -45.0 a0.0^x66.W 33.0^x2B.75° GI,G2 +35.0 -35.0 3 architect. o , W a -a 32.0"X64.0" 25.0"X27.75"' GI,G2 +45.0 •45.0 36.0"X72.0° 29.0"X31.75° G1,G2 .+35.0 -35.0 TABLE OF CONTENTS z 52A"X 44.0" 45-V X 17.75' G1,G2 +40.0 •40.0 52.0"X 60.a^ 45.W x 25.75^ G1,G2 +30.0 -30.0 .t M N•-z a° SHEEW DESCRIPRON 1 Typical elevations,design pressures and general notes 40.0"X 48.0" 41.0"X 19.75" G1,G2 +40.0 •40.0 48.WX 64.0° 41.0"x 27.76' G1,G2 +30.0 .-30,0 °ATE 6123114 =. z 2 Horizontal cross sections scuE N.T.S.fli ° 3 Vertical cross sections - 44.0"X 520" 37.0"X 21.75°, G1,G2 - +40.0 -40.0 44.0"X 70.0^.- 370 X 30.75" G1,G2 +30.0 -30.0 Dyye,$y; ,1K m' 4 Buck and frame anchoring cHK.ar: LFS 3 5 Bill or materials,components 8,glazing detoils A0.0"X 58.0" 33.0" "X 2Q.75 G1,G2 k40.0 •40.0 40.0"X 72.0" 33.0^X 3L75' G7,G2 +30.0 -30.0 Dw,vmac No.: � t 52.0"X 72.0" 45.0"X 31.79 G1.G2 +25.0 -25.0 FL-15819.8 a SHEET 1 OF 5 N i _ 0 d R:\OientAWincore PERMANENT\A-Florida Product Approvals\FL-15819 Double Hung\C-Drawings\Current\FL-156199.dwg,2.5 Z V Q Xo 2 n a; I° N to 08 � 0 0 sz N o. a X® rn D e n r I0 W Al lV m rn mac. m m� C 2 o D CDF" �o r n �� O D Z O T ate.: 0. 0 pa z ayil 0 $ IL—A- .• eWn en O 0 O Z G No.43409 xy PRODUCT: Document. Proparod 7700/9900 SERIES,I� Lyndon_V. Schmidt w �i�`Q�• OniDP•.������� I .m 4 6 01 17 UPDATE TO 6TH ED.' 2017 FBC LFS Vinyl Double Hung Window P.E. No. 43409 �� 6'1®®..�� ,``���o Z 3 5 10 16 REVISE INSTALLATION SCREWS LFS ///Pfl'1 lltll 2 1/27 15 UPDATE TO 5TH ED. 2014 FBC LFS PART OR ASSEMBLY: GZ� BUILDING CONSULTANTS,,IN�. Icp Tri in 1 8/25 14 REVISE SERIES N0. JK �L P.O. Box 230, Valrico, FL 33595 � i' NO DATE BY HORIZONTAL pho D No.: 813.659.9197 REVISIONS CROSS SECTIONS FSPE C.A. No. 9813 ®2014 R.W.BUILDINO CON-1—NTS INC. ' . R:\Cffents%Wjnccre PERMANENT\+-Florida Product Approvals\FL-15819 Double Hung\C-Drawings\Current\FL-15B19.B.dwg,35 .. 'D lV 09 M .. 41S m a � 0 0 .. n � ® .. �' I-1/4°MIN. EMB.RYP.) O Ca9 W off - g� 00 t� a� ty 1-11,4"MEN. jj EMB,(fYP.) Ip sia � x +.t " . o .. .. b p a„ �a No.43409 PRODUCT: Documonto'Prap-md sy i�• SfATEOR ,, x 7700/ 9900 SERIES Lyndon,P.,Schmidt rr'�.°. .6R10,�,+a•'���`'••' z" 3 5/40.17 UPDATE tNSTALLATION SCREtYSF'SC L S Vinyl Double Hung Window P.E. No. r3-009 o o '• y W 2 1/27 15 UPDATE TO 5, ED. 2014 FBC LF•S PART OR ASSEMBLY: BUILDING CONSULTANTS, cif in 1 e/25/14 REVISE SERIES NO, JK P.O.Box 230, Valrico, FL 33503 (c" co �' NO,, DATE BY VERTICAL phono No.: 8t3.sSs.91s7 REVISIONS CROSS SECTIONS F`BPE OA. No. sa13 0 2O14-RM.BUILDING CONSULTANTs IND.. W MAX.O.C. %• ,°�Gp�a¢°m ro do. o 2 o 0 oz 9mU ° °- m 0:0 n 2X F !✓ 1X p 1XBUCK >✓ (\ E oz BUCK BUCK BUCK DIRECTTO _ a d r - TYP.MASdNRY n FRAME----, - �( FRAME-- , MASONRY —a Q MASONRY w OPENING a OPENING a MASONRY w z^x OPENINGx i H m(� cn�sr BUCICANCHORING FRAMEANCHORING FRAME ANCHORING �J m 2X Buck I Buck Direct to masonry m a CONCRETE ANCHOR NOTES. ° 1.Concrete anchor locations at the comers may be adjusted to maintain the min o a edge distance to mortarjoints. w w 2. Concrete anchor locattons noted as'MAX.ON CENTER"must be adjusted to ¢�' a maintain the min.edge distance to mortarjoints,additional concrete anchors i a may be required to ensure the"MAXON CENTER"dimensions M are not exceeded. 2 3.Concrete anchor fable: z AIVCkORa; :.NCWOa;; M... CLEAE' ............ n m c ::. :::::: IOIufASONRy TOADJACEtVT i ?YPE SJZ ... . .BEDhf1ENF z a �::a:'<Et2GE:::;:•tr::•::::::::;•:;:�:::AAICHOR'::::�::�:: - tl.'1 N�-� u :::.:`tiW:t;:•;::: : 6123114 i a TAPCON® 1%4" 1;- onrE 10-- 2" 4" D&TE . .N.T.S. ° ELCo ows.Br. . JI< m . ULTRACONtl° 4" cWL By, LFS 3. WOOD SCREW INSTALLATION NOTES: otuvnea rta `r 31.Maintain a minimum 5l8"edge distance,I"end distance,&f"o.c.spacing of 'r=L-15819.8 wood screws to prevent the spliffing at wood. ° SHEET 4 OF 5 ®. BILL OF MATERIALS REM 0 DESCRIPTION MATERIAL A 1XBUCKSG>=0.42 WOOD a =��,.' ¢:►�=ci n. B 2XBUCKSG>=0.42 WOOD �� `r a�) m C IN MAX.SHIM SPACE N (� Q N zv �',yt� o o' D 1/4'X 2v'14"PFH NCO OR TTW CONCRETE SCREW STEEL " r—1.4" ••. y�j e ti o MASONRY-3,000 PSI MIN,CONCRETE CONFORMING TO ACI �i ..........�6�� �>M m E 301 OR HOLLO BLOCK CONFORMING TO ASTM 90 CONCRETE �a n D o �t/ttT ��� o d m z fill%F #8 X 2"PAN HEAD/TRUSS HEAD WOOD SCREW(1-3/9'MIN.EMBEDMENT) STEEL 0.07, �II 0 V.o G T/4"X 2-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL o - 9 z o z chi 1 FRAME JAMB*(DH 7701) PVCE. 6 e 9 Q o a 2.6^ I�La.7t° 2 SILL!(DH 7703) PVC 325 a w m a a(a 3.. FRAME HEiAT3'(DH 7701) PVC 4 UPPER SASH STILL (SE 3035) PVC' 3 1 FRAME HEAD&JAMB 2 SILL Topes STILE o v; 5 LOWER SASH STILE'(SE 3045) PVC a 'mod 6 GLAZING BEAD' PVC 7 KEEPER RAIL UPPER SASH'(SE 3034) PVC 9 LOCK RAIL LOWER SASH"(SE3046) PVC o o 11 TOP RAIL UPPER SASH-(SE 3037) PVC G.3 (� ti ci 12 BOTTOM RAIL LOWER SASH*(SE 3047) PVC 16 WEATHERSTRIP ULTRA FAB.270 PILE-270-1875Bui 3 17 WEATHERSTRIP SILLBULB(AMESBURY 32690) - 0.051 °'° m a1 19 HEAD ADAPTER'(DH 3005) PVC 20 LOCK 8513/8845 LAWRENCE PVC r. SASH STILE ITNG�BEAD., KEEPER,RAIL 21 KEEPER 2700-214LAWRENCE PVC Bottom 7 UPPerSash ` 22 #8 X i"PFH(VINYL LOCK SCREWS) STEEL a� 23 #6X1-1/2'PFH(VINYL LOCK SCREWS) STEEL 204„ 24 TOP SASH TILT LATCH-ASHLAND PVC 1.66' `� 205f bo, m 28 PIVOT BAR-CALDWELL P t:,, (� 0 29 48 X 1/2"SELF TAPPING PPH SMS STEEL o cs Ll m 0.07, THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY � _ OAT' N —0.07 EXTRUDERS LICENSEES IN AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". I N N N 1.42' d z d z Z O m LOCK RAIL TOP RAIL BOTTOM RAIL w Q 9 Lower Sash UPPers.11 �2 Lower Sash x r oz�E0 w M ¢N¢1n a 1/2"GLASS BITE 1/2"GLASS BITE zo j lilb"X112' Vlb"X1/2".. o GLAZINGTAPE- 7/8'THICKGLASS GLAZING TAPE 7/86'THICK GLASS }I p,ql�� I �"� o ww¢ p 1/8"ANNEALED 1/8"ANNEALED 1.31 _ m uT 0.030"Saflexo PVB INTERLAYER z �. AIR SPACE 1/8"ANNEALED 'H c°s a GATE: 6/23/14 " 1/8"ANNEALED 1/8"ANNEALED 10 0 110 0 SCALE N.T.S. INTERCEPTSPACER 1NTERCEPTSPACER o OS" 1" c a JK m GLAZING DETAIL GLAZING DETAIL "I cxk.sr: LFS 3 Cv1 (See GeneralNote3,Sheet.l) �'a (See General Note3,Sheet1) Y9 NEADADAPTER � PIVOTBAR owniUc Ha.: a FL-15819.8 N SHEEP S OF S 0 C m a • Plan Review Windows & Doors 1) Need manufacturing installation specifications. 2) Must meet sections R308 and R6.12 of the.2017 F.B.C. 3) If windows are to be installed inside the historical district,they will need to be approved by-the historical committee. 4.) No other work shall be permitted (framing, plumbing, and mechanical) unless otherwise specified.. 5) This is for replacement (glass for glass) only.. If you wish to change from screen or vinyl windows to glass,then additional information is required. 6:) All windows to wall connectioons shall be left visible for inspection-. 7) All labeling and stickers shall remain on windows until final inspection. 8) No work shall start without permit first. 0 F�wfltuu City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: C/o co Woo C Cl Date Received: 7b, hq Site: 3 3 Si Ve- K� Permit Type: '"A .0ti u ?,.?- ), u, douvy-M014 - Zf'n f&7` Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sh shall be kept with the permit and/or plans. JUL 12 2019 X j Kalvin t4 r -Plans Examiner Date //#1"redwhen o meowner comments are present)