HomeMy WebLinkAbout19-21614 CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813) 780-0020 21614
EMERGENCY GENERATOR PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 21614 Address: 6136 RIDGEWAY DR
Permit Type: FIRE EMERG GENERATOR<30K ZEPHYRHILLS, FL.
Class of Work: FIRE-EMERGENCY GENERATOR Township: Range: Book:
Proposed Use: MOBILE HOME SUBDIVISION Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 03-26-21-0130-00000-0380
Improv. Cost: 2,100.00 OWNER INFORMATION
Date Issued: 8/07/2019 Name: PIERCE, JOHN & BETTY
Total Fees: 100.00 Address: 6136 RIDGEWAY DR
Amount Paid: 100.00 ZEPHYRHILLS, FL. 33542
Date Paid: 8/07/2019 Phone: (813)788-5756
Work Desc: INSTALLATION EMERGENCY GENERATOR
CONTRACTORS APPLICATION FEES
PATTIE ELE REFRIGERATION FIRE PERMIT FEES 100.00
Ins ections Re uired
FIRE INSTALLATION-Final
ELECTRICAL FINAL
FINAL
Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire
prevention and protection related activities such as inspections, plan review,administrative fees,and other
costs related to the aforementioned.
Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of
the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final
inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All
work shall be performed in accordance with City Codes and Ordinances.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMME MENT."
CONTRACTOR STbNATURE PERMIT OFFIC
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
ZEPHYRHILLS FIRE RESCUE - 813-780-0041
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received �� 7�� __ ��j O
Phone Contact for Permitting
Owner's Name v G{_// Owner Phone Number
l,7- Zff
Owner's Address 4/ e fq✓(/1 Owner Phone Number
2e Al; s ,3f r Owner Phone Number
JOB ADDRESS O I.✓ LOT#
SUBDIVISION PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR 0 COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL =
DESCRIPTION OF WORK l f��A C'US ompr- l0 V.Wei eftrf A,-
BUILDING SIZE SQ FOOTAGE HEIGHT
144-4
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION
®ELECTRICAL $ 02 (/�✓
/ 0 ` D D AMP SERVICE 0 DUKE ENERGY ®/W.R.E.C.
=PLUMBING $
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS = ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE ��- REGISTERED Y/ N FEE CURREN Y/N
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address I License#
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN F Y/N
Address I License#
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address L License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County na-u|otiono. The undersigned assumes responsibility for compliance with any
applicable deed restrictions. ~ .
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state |ovv. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furtharmore, if the owner has hired m contractor orcontractors, he is advised to have the contractor(s) sign
portions of the "contractor B|ooh. of this application for which they will be responsible. If you, as the owner sign as the
controctVr, that may bean indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION UK0PAClJUTIL0[;ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buUdinga, change of
use in existing bui|dingo, or expansion of existing bui|dings, as specified in Pasco County Ordinance number 89-07 and
90-07. as amended. The undersigned also undemtandn, that such fees, as may bedue, will be identified at the time cf
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power na|eone. If the project does not involve a certificate of occupancy or
final pnvmar na|eome, the faoo must be paid prior to permit issuance. Furthermore, if Pasco Counb/VVoher/Sevvar Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): |f valuation of work ia $2.60D.ODmrmore, |
certify that |, the app|icant, have been provided with e copy nfthe "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant in someone
other than the "owner", | certify that | have obtained a copy ofthe above described document and promise in good faith to
deliver itto the^mwner^prior bocommencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has
commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | o|no
ne�ih/that | understand that the regu|aUonoof other government agencies mnayapply to the intended
�work, and that itim
my responsibility to identify what actions | must take tobeincompliance. Such agencies include but are not limited to:
- Department ofEnvironmental Protection-Cypress Bayheado, VVed|ond Areas and Environmentally Sensitive
Lands,VVaterMaatavvaterTnaatmont.
- Southwest Florida VVotar Management Dintrint40aUa, Cypress Boyhmode, Wetland Anaoa, Altering
Watercourses.
' Army Corps ofEng(neero'GeavvoUs. Oocha. Navigable Waterways.
' Department of Health & Rehabilitative Services/Environmental Health Unit-WeUs, VVamtevvobar Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authohb+Runmmys.
| understand that the following restrictions apply to the use mffill: '
- Use of fill is not allowed in Flood Zone^V''unless expressly permitted.
- |fthe � material is 0o'be used /n Flood Zone ^A", it is understood that o drainage plan addressing a
^ fill
volume" will be submitted at time of permitting which is prepared by professional engineer
licensed by the State ofFlorida.
- If the fill material is to be used in Flood Zone 'A" in connection with o permitted building using stem vva||
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, | certify that use of such 0l will not adversely affect adjacent
properties. |f use of fill ie found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit )onuod under the attached permit application, for lots )aoe than one U>
acre which are elevated by fill, an engineered drainage plan |orequired.
|[| amthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction, | understand that a separate permit may be required for electrical vvork,
p|urnbinQ, aiQnm, vveUs, poo|s, air condihnninQ, gos, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of permit prevent the Building Official from thereafter
requiring correction of errors in plans, construction or violations oy any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within mix months of permit iosusnce, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be nequented, in writing, from the Building C}ff|nie/ for o period not to arcaad ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IFYOU INTEND 77O OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
)
OWNER PR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before-me this
by -by
Who isTa—r6—personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
Notary Public Notary Public
8/2/2019 03-26-21-0130-00000-0380 1 Pasco County Property Appraiser
Parcel ID 03-26-21-0130-00000-0380 (Card: 1 of 1)
Classification 00200-Mobile Home
Mailing Address Property Value
PIERCE JOHN S & BETTY M Ag Land $0
6136 RIDGEWAY DR Land $22,200
ZEPHYRHILLS, FL 33542-7998 Building $55,794
Extra Features $1,264
Physical Address
6136 RIDGEWAY DRIVE,
ZEPHYRHILLS, FL 33542 .lust Value $79,258
Assessed (Non-School Amendment 1) $54,610
Legal Description (First 200 characters) Homestead -$25,000
See Plat for this Subdivision Additional Homestead -$4,610
ZEPHYR RIDGE PB 26 PG 78-80 LOT 38
OR 3936 PG 1001 Non-School Taxable Value $25,000
Jurisdiction School District Taxable Value $29,610
CITY OF ZEPHYRHILLS Warning: A significant taxable value increase may occur when sold.
Click here for details and info. regarding the posting of exemptions.
Land Detail (Card: 1 of 1)
Line jUse Code Description Zoning'Units ;Type ;Price 'Condition ?Value
1 0200M LP1-1 Mobile Home Sub OOM1 6,000.00 SF $3.70 1.00 $22,200
Additional Land Information
Acres Tax Area FEMA Code Res Code Com Code I Condo Code
0.14 i 30ZH X ZIDE ZIDE € ZIDE
View Sketch Building Information - Use 0200-Mobile Home (Card: 1 of 1)
Year Built 1998 Stories 1.0
Exterior Wall 1 Above Average Exterior Wall 2 None
Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle
Interior Wall 1 Drywall Interior Wall 2 None
Flooring 1 Sheet Vinyl Flooring 2 Carpet
Fuel Electric Heat Forced Air - Ducted
A/C None Baths 2.0
Line Code ;Description Sq. Feet :Value
_ _ . _ ._ .. i ......_. . _...... __.. ._ ._.... __... ....
NG AREA 1 BAS01 LIVING 1,080 $45,928
2 FGR01 FINISHED GARAGE 400 $6,804
3 FSA01 FINISHED SCREENED ALUM PORCH F 160 $3,062
Extra Features (Card: 1 of 1)
Line 'Code Description Year Units Value
1 ' RDWSWC DRVWAY/SIDEWALK CONC 1998 372 $718
2 RCAC-4 CENTRAL A/C 1998 1 $546
Sales History
Previous Owner: CHASE BERT
Month/Year Book/Page ;Type DOR Code Condition Amount
05/1998 3936 / 1001 Warranty Deed mmVacant $13,000
t
05/1997 3756 / 1689 Quit Claim Deed Vacant $0__.__.
. . ..................._..-.._.__............. ...__..... ....__..._....__.....:..._..... ......_.._.._.........__.._. .......:. . ..
01/1995 3 3388 / 0287 Warranty Deed Vacant i $0
05/1994 _3294../...0902.... Warranty Deed... ..... Vacant ._..........__....$o....._.__........
08/1987 1633 / 0186 Quit Claim Deed Vacant 1 $0
https://search.pascopa.com/parcel.aspx?parcel=2126030130000000380 1/1
Ra tia
E I eea'`L�;. r a
o Heating cd, ting
39111 Pattie Road
Zephyrhills,FL 33540
813-782-3319
sales@pattieelectric.com
Work, rd e
3648-101 7/31/2019 LELAND A 24603
0 13 :
Betty Pierce Betty Pierce
6136 Ridgeway Drive 6136 Ridgeway Drive
Zephyrhills, FL 33542 Zephyrhills, FL 33542
813-788-5756
Item Code Description Hrs/Qty Price Amou
> 7/9/2019 TUE 10: 15 AM> Called in by: Betty
Customer would like a quote for a home generator installation.
> 7/10/2019 WED 11: 10 AM> LELAND A:
Pattie Electric will install a 16 kw Generac stand by generator with whole house
transfer switch. Customer will be purchasing her own generator and we will just be
installing it.
The generator will be located in the back yard adjacent to the undergroud post
mounted electrical service. The generator conductors and control wires will be
routed underground to the location of the service.
The transfer switch will be mounted to the existing wood service post.
Pattie Electric will submit a load calculation for an electrical permit, schedule a
disconnect with Withlacoochee River Electric, and schedule an inspection with the
building department for the generator installation. Once the final inspection is
passed, it is the responsibility of the building department to release a
reconnection order to Withlacoochee River Electric to reconnect the electrical
Page 1 of 2
service.
The customer's electrical service will be disconnected for approximately 6 hours to
complete the installation.
The generator will be programed for bi-monthly test cycles to ensure proper
operation.
The customer will be responsible for arranging the installation of a LP tank, LP
regulator, and plumbing to the generator location.
This generator has an hourly fuel consumption of 2.03 gallons of LP at 500 load
which equates to 194 .88 gallons over the course of 4 days of continuous use. This
is the recommended length of run time for this installation.
All work performed by 'Pattie Electric will be subject to an electrical inspection
by the building department and be carried out in a workmanlike manner to ensure
compliance with national and local electrical codes.
> 7/26/2019 FRI 12:33 PM> LELAND A:
Needs disconnect scheduled for 8/6/19 by the utility provider.
Needs permit and inspection scheduled for 8/6/19
City of Zephyrhills may require a load calculation for the permit. Request
direction from DP if necessary for the load calc.
Generator and transfer switch need to be placed and underground conductors
installed on 8/5/2019. Remainder of wiring to tie into service to be completed on
8/6/2019 following the disconnect.
> 8/2/2019 FRI 11:39 AM> LELAND A:
Tech will need help unloading and placing the generator on 8/5/19
Price is Per Stated Quote 1.00 2100.00 2100.00
Subtotal
2100.00
All material is guaranteed to be as specified. All work to be completed in a professional manner according to standard practices. Any alteration or
deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above
the estimate. All agreements contingent upon delays beyond our control. Purchaser agrees to pay all costs of collection,including attorney's fees.
Signature Date
a
r.
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: h I C�r 1,G d- �e �YJ'�e y 41 Q �1
Date Received:- �l
Site: oz
Permit:Type: r)sr �'�iu ��0
Approved w/no comments:�Approved w/the below comments: ElDenied w/the below comments: El
This comment sheet shall be kept with the permit and/or plans.
1 �40 R"lAwss—Building Official Date Contractor and/or Homeowner
(Required when comments are present).
�L°LjM
ALL WORK SHALL COMPLY WITH GENERACo
NFFA CODES AND STANDARDS
�„IEWDA �� GUARDIAN° SERIES
CrrYmm of zEPHY s I&0/22 kW s'dential Standby Generators
Air-Cooled Gas Engine
INCLUDES:
• True Power- Electrical Technology Standby Power Rating
F4cdei..00 703t ^.ui)t $7-t ':1.;nir:!!ni-Eiis:fi ;i-16 kvb 60 i-iz
• Two Line LCD Multilingual Digital h;i;;d;:GO a{iS: :; I;rninum-t3isclu-t)-16 k,'0-c0 Hr..
Evolution'"Controller(English/Spanish/ tviocels .007039 i,i Ov'I(i38-; iAl,n unum Bisque)-^G Kr'!6,iiz
French/Portuguese) �_
f• odels 0007043-2.C 0.I042-2(Nuirdn;rrn-Eii:;y_si-22 J.,.,11".
• Two Transfer Switch Options Available:
100 Amp,16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 5 for Details. ®- N ;�j�7
• Electronic Governor '`'
• Standard Wi-Fi' Remote Monitoring
4
• System Status&Maintenance Interval LED Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector GENERAC'
• Direct-To-Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty• Listed and Labeled by the Southwest Research Institute allowing OOUS
as close as 18"(457 mm)to a structure.* LISTED QUIET-TEST-
installation
*Must be located away from doors, windows, and fresh air Note:CUL certification only applies to unbundled units and units packaged with
intakes and in accordance with local codes. limited circuit switches.Units packaged with the Smart Switch are UL certified in
https:/lassets.swri.org/IibraiylDirectoiyOtLi'stedProducts! the USA only.
Constructionlndustry/973_DOC._204__13204-01-01_Rev9.pdf
FEATURES
n INNOVATIVE EfJGINE DESIGN&RIGOROUS TESIING are at the heart of Generac's G SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION:
success in providing the most reliable generators possible.Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard on
lineup offers added peace of mind and reliability for when you need it the most.The all Generac models.It provides optimized FAST RESPONSE to changing
G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
extended run limes in high temperatures and extreme operating conditions. electronically torque-matching the surge loads to the engine. Digital
voltage regulation at±1%.
Q TRUE POWERY' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave C, S114GLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
form produce less than 5%Total Harmonic Distortion for utility quality power.This allows network provides parts and service know-how for the entire unit,from the
confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component.
such as variable speed HVAC systems.
0 TEST CRITERIA: 0 GENERAC TRANSFER SWITCHES: Long life and reliability are
PROTOTYPE TESTED NEMA M137-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
c MOBILE LINK" REIAOTE 11,401,411ORING: FREE with every Guardian Series Home w GENERAC _
standby generator.Allows you to monitor the status of your generator from anywhere in the
world using a smariphone,tablet,or PC. Easily access information such as the current ,= PROMISE
operating status and maintenance alerts.Connect your account to your authorized service
dealer for fast,friendly and proactive service.With Mobile Link,you are taken care of before
the next power outage.