HomeMy WebLinkAbout19-21626 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21626 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 21626 Address: 39250 8TH AVE Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SUNSET ESTATES #2 Est.Value: Parcel Number: 12-26-21-0310-00000-0960 Improv. Cost: 800.00 OWNER INFORMATION Date Issued: 8/12/2019 Name: WOOSLEY, AARON & SMITH,DIRACE Total Fees: 67.50 Address: 39250 8TH AVE Amount Paid: 67.50 ZEPHYRHILLS, FL 33542 Date Paid: 8/12/2019 Phone: (813)479-3537 Work Desc: TRUSS REPAIR TREE DAMAGE INSIDE THROUGH DRYWALL CONTRACTOR(S) APPLICATION FEES COMMERICAL INTERIOR SOLUTIONS IN BUILDING FEE 67.50 Ins Dectio s Required FOOTER 2ND RO­U PLU VB MI SC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER misc. ROUGH ELECTRIC LINTEL misc misc. IST ROUGH PLUMB PRE-METER INSULATION WALL misc. DUCTS INSTALLED WATER misc DRIVEWAY PRE-SLAB SHEATHING misc. misc. CONSTRUCTION POLE-, FRAME misc. I misc. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 4#0 CONTRACTOR SIGNATURE PERMIT OFFIOR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting ...... I.. Owner's Name I Act 1^6 L, voos 1A, Owner Phone Number I ?/3 — (/7? Owner's Address ,14 uivril F633h2 Owner Phone Number F_ Owner Phone Number JOB ADDRESS 4,1/s LOT# C�� SUBDIVISION PARCEL ID# 00 0 0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR[a,,,-'ADD/ALT 0 SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME u STEEL DESCRIPTION OF WORK t-uss L(_)�t�a4px _ U BUILDING SIZE SQ'FOOTAGE HEIGHTF [:OBUILDING VALUATION OF TOTAL CONSTRUCTION "0' 00 =ELECTRICAL 1$ AMP SERVICE DUKE ENERGY 0 W.R.E.C. =PLUMBING 1$ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS Q ROOFING Q SPECIALTY 0 OTHER V FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO 7�1 jl u Hli 1 1 1 1 1+4 BUILDER COMPANY SO A A0 h- SIGNATURE REGISTERED I(V N FEE CURREN Y/N -7 1-3 Address ori im e, License# I (, 6C, 02 763 ,�zb 3 3 7M ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N_J FEE CURREN LY/N Address _7 License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN L_y LN__J Address License# F__ RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsfiarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions. Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) i\Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED The undersigned understands that this permit may be subject to"deed" which may bo more restrictive than County ' u|aUmno. The undersigned assumes responsibility for compliance vvithron*y applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired o contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not |ioonaad as required by |ovv both the owner and contractor may be cited for a misdemeanor violation under state |avu If the mxvnmr or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Li6ensing Section at 727-847- 8009. Furthermona, if the owner has hired a contractor orcontractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, om the owner sign mothe contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understando that Transportation Impact Fees and Recourse Recovery Fees may apply bo the construction mfnew buildings, change cf use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 9O-O7. 00amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" mr final power release. If the project doennot |nvo|vamcertURcateofmouupmnnyor final power release, the fees must be paid prior ho permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must ba paid prior bz permit issuance in accordance with applicable PmeooCounb/ordimanoee. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,-as smmended): |f valuation of work io $2.5OO.00or more, | certify that |, the applicant, have been provided with a copy of the"'Florida Construction Lien Lsmm�-Honnecmmne/s Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the opp|k:oni is someone other than the"mmmer". | certify that ! have obtained e copy of the above described document and promise in good faith tV deliver itto the"ownmr"prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land develo Ipment. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has .commenced prior to iamomnma of permit and that all work will be performed to meet stondomdmofaU laws regulating construction, County and City codes, zoning regulations, and land development regulations i jurisdiction. | also ced�vthat | understand that the regulations of other govamnrnmntagencies nmayapply bo the inbnndadwork, and that itim my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: � -� Department ofEnvironmental Protection-Cypress Qayhmodo, Wetland Areas and EnvironmontaUy8eneiUve Lendm,VVaW*c8Waohawxaber Tmwebnerd. - Southwest Florida VVabar Management District-Wells, {�ypr�m� B��he�do Wetland Areas, Altering � . . '- rmy C6ros of.Engineers-Seawalls, Docks, Navigable Waterways. DepMmeht,,.,0f Health & Rehabilitative Services/Environmental Health Unit-WmUo. VVastevmxbar Treatment, Environmental Protection Agency-Asbestos abatement. S-.-�.,,_''FederalAviation Authority-Runways. | u thitthm following restrictions apply the of fill- Use pf fill ianot allowed in Flood Zone^V"'bh|esaaxpneo' |ypemmdted. - If the � mohyhg is hm'ba used in Flood -Zone ^A"' � is understood that a drainage plan addressing m "compensating volume" will be submitted at time of permitting which is prepared by professional engineer licensed by' ` - If the fill material is to be used in Flood Zone ^A^ in omnnmoUom with.a permitted building using item vvaU construction, |certify that fill will be used only to fill the area within th b6:lxxaU. - If fill material is to be used in any area, | certify that use of m0ok0i viUio6t advanae|y affect md|omard properties. If use of fill is found to adversely affect adjacent no ��i . tho owner may be cited for violating the conditions of the building permit issued under the edbanhed+pernmit.application, for lots less than one (1) acre which are elevated by fill, oh engineered drainage plan iarequired. If| monthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that o separate permit may be required for electrical xvVrk' plumbing, migns, vvmUs' pon}a, air conditioning, gom, or other installations not opmoUicaUy included in the application. 8 permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit imouonoe, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for m period not tmexceed ninety (SO) dayo and will dmmomotnsba justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job.is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this_ Subscribed and sworn to(or affirmed)_before--this Who is/ar6 personally known to me or has/have produced Who is/are personally known to me or hasihave produced identification. as monnnoaovn. Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped STRUCTURAL NOTES Q ELECTRONIC VERSIONS OF STRUCTURAL DRAWINGS ARE THE SOLE, COPYRIGHTED PROPERTY OF KWA ENGINEERS LLC. ELECTRONIC VERSIONS SHALL NOT BE TRANSFERRED OR SHARED WITHOUT THE EXPRESS, WRITTEN PERMISSION OF KARINS ENGINEERING GROUP INC. SITE LOCATION STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL ;°: il;. :< :s:;L`,I: ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. DIMENSIONS AND EXISTING CONDITIONS THROUGHOUT THE PROJECT SHALL BE FIELD VERIFIED. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE o CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE REPAIR PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING REPAIR. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,TEMPORARY BRACING, «" .r GUYS OR TIEDOWNS. UNLESS CLEARLY SHOWN ON THE STRUCTURAL DRAWINGS, NO PENETRATIONS/CONDUITS SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT A PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO IDENTIFY SUCH PENETRATIONS/CONDUITS BASED ON INFORMATION PROVIDED BY ALL SUBCONTRACTORS AND TO SUBMIT DETAILED AND DIMENSIONED FLOOR PLANS TO THE STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL PRIOR TO IMPLEMENTATION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY LABOR AND MATERIALS ASSOCIATED WITH ADDITIONAL REINFORCEMENT OF STRUCTURAL MEMBERS RESULTING FROM INTRODUCTION OF SUCH PENETRATIONS/CONDUITS. DESIGN LOADS: 1 SITE LOCATION S—Q SCALE: N.T.S. THE STRUCTURAL SYSTEM FOR BUILDING DEPICTED HEREIN HAS BEEN DESIGNED ACCORDING TO THE FLORIDA BUILDING CODE 2017 (6TH. ED)" EXISTING BUILDING - CHAPTER 5 - REPAIRS. THE STRUCTURE HAS BEEN DESIGNED TO RESIST THE FOLLOWING SUPERIMPOSED LOADS: (!) . 1. ROOF LIVE LOAD ........ 20 psf = Q 2. ROOF DEAD LOAD'...... 10 psf - CL 3. CEILING DEAD LOAD ... 5 psf } W 4. WIND PRESSURE......... +16 psf/-28 psf (FACTORED) a; � i CL S N V) WOOD: c � STRUCTURAL WOOD COMPONENTS (TRUSS BRACING) SHALL BE CONSTRUCTED OF MINIMUM NO. 2 GRADE SOUTHERN PINE m ACCORDING TO AF&PA NDS. WOOD IN CONTACT WITH CONCRETE OR MASONRY,AND AT OTHER LOCATIONS AS SHOWN ON THE � DRAWINGS, SHALL BE PROTECTED OR PRESERVATIVE TREATED. MEMBER SIZES SHOWN ARE NOMINAL UNLESS NOTED OTHERWISE. PLYWOOD SHEATHING SHALL BE APA RATED 1/2 PERFORMANCE CATEGORY STRUCTURAL 1 EXPOSURE 1 AND COMPLY WITH APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE. MANUFACTURED PRODUCTS: ALL MANUFACTURED PRODUCTS INCLUDING BUT NOT LIMITED TO CONNECTORS, ADHESIVES, ENGINEERED LUMBER AND ACCESSORIES SHALL BE INSTALLED AND CURED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 8 CONNECTORS: S d CONNECTOR MODEL NUMBERS SHOWN ARE STRONG-TIE CONNECTORS AS MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, 2 SITE MAP U.N.O.,AND SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S DIRECTIONS TO RESIST THE SPECIFIED LOADS. S-0 SCALE: N.T.S. E UNLESS NOTED OTHERWISE FOR EACH CONDITION, ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL HAVE MINIMUM CORROSION RESISTANCE OF Z-MAX (OR EQUIVALENT) OR HOT DIP GALVANIZATION'WITH HOT.DIP GALVANIZED loco 11 FASTENERS. ALL EXPOSED CONNECTORS AND FASTENERS SHALL HAVE MINIMUM CORROSION RESISTANCE OF STAINLESS STEEL TYPE 316. t 0 z cf) SUGGESTED SEQU REh NG AS ac SHORING AS tSfLo4NIMPE '�P 0 v"I' � AGED TRUSSCObum I t4p-'T%O0pLo—t DOD GUSSET'. X14uor- j;' A SH —4K ADHESIVE CURED. AFTER EPDXY folwls ISORING DAMAGED SECTION: 0 TRUSS REPAIR LOCATION. SCALE:, N.T.S. iview F%F- Fee%& C11-y of: Z. Pt4vy I IE I k- HRS8 STRAP TIE AT TOP (2) CUT TO FIT SINGLE SHEET APA RATED OF TRUSS w/ (10) 10d TYP U.N.O. PLYWOOD ONE GUSSET TO EACH FACE OF NAILS AT EACH SPLICE TRUSS WITH (2) ROWS OF 6d COMMON -j NAILS 03" D.C. STAGGERED THROUGHOUT < ALL MEMBERS WITHOUT SPLITTING LUMBER, CL APPLY SIKADUR 32 EPDXY ADHESIVE AT Od Ld ALL CONTACT SURFACE r CL Lli DAMAGED SECTION TO BE REPLACED WITH NEW 2"X4" EXTERIOR WALL r. 7 EXISTING GIRDER TRUSS SAWCUT TO REMOVE SECT ION OF REPLACE EXING DAMAGED SECTION N.O. TO BE SnTI U ADDED 9 HANGER WITH SHORING I-0. SHORING a,-o. 91-0" HUS26 ±26'-O" NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN COMPLIANCE W/ ALL APPLICABLE CODE REQUIREMENTS �2 TRUSS REPAIR SCALE: N.T.S. S-21 I ULIUS z� October 17, 2019 Building Official City of Zephyrhills Building Department 5335 8th St, Zephyrhills, FL 3354 RE: Description of Emergency Repair Work Property Address: 39250 8th Ave, Zephyrhills, FL 33542 Owner: WOOSLEY AARON &SMITH DIRACE Dear Applicable Building Official, I have visually observed the truss repair work outlined on the attached sketch. It is our understanding due to the emergency nature of the repair the truss work was covered up prior to inspections. In my professional opinion the truss repair framing, sheathing, nails and adhesive were done as outlined in the approved truss repair sketch, and is compliant with the Florida Building Code-2017- Building, 6th Edition. Please allow this letter to serve as a record of work completed to mitigate storm damage. If you require additional information, please contact me at the number below. Thank you for your time. Julius Keblinskas, Sr. attachment: sketch from KWA Engineering, LLC Manager, Julius the Architect, LLC Architect AR 91486 PO Box 10177 juliusthearchitect@gmail.com St. Petersburg, FL 33733 727-543-6061 ' U � i ! •� CO 2' PROOV p D' SHfgTHING AS co N B4CED SECTION NEEDEp. TEMPpJy l� 3. CUT AND SHORING AS wr 11.. SECTION; REPLACE DA 'C 4' INSTAL(,pOEO 1RUSS m V E SRECp ET. k acu 1 CURED. FOXY i '• -C S"1 SCAR UN 7SR AIR LO YJ � (2)�3'cUT To EP CATION AT .t PLYWOOD pNi'TT'SINGLE S '•� TRUSS WIT?GUSSEt TOHEf:7 APA RA a'`' •� EMO"O.C.(2)ROWS EACH FACE p� HRSB APPLY SKAOUR DUT SPEUMN DUGHOUT N'VS AT /H(10) I'd quEPDXy ADNESN BER. EACH SAUCE do OAMAG CONTACT SUR ACE TO B�SECTION KrTH NREPLACED /1 2-X4-TYp U.M.O. W 2 X4" / l GIRDENG R TRUSS / *5--0. REPLACEHANGER SAWCUT TO J EMOVE _ HUS26 SHORING DAMAGED SECTION 0, 'Q --� 9'-.0• SHORING SECT ON La U.N.O. TO gE ADDEO N 0) 8•_0" EXTERIOR WALL, t~n � *26'-0 9 1-0" a CONTRACTO _ Au APPUC 6LE VERIFY ALL DIM `�I ._ n"S 1 r{ CODE REOUIREMENjs NS IN COMPLIANCEn�" 2 M R �Fas. ? S—] scARUN TSREPAI LL aCL ~�;