Loading...
HomeMy WebLinkAbout19-21669 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21669 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL `PERMIT-INFORMATION LOCATION INF.ORMATIOW- Permit#:21669 Issued: 8/22/2019 Address: 39684 DAWSON CHASE DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 225,863.25 Total Fees: 18,163.97 Subdivision: HIDDEN RIVER Amount Paid: 18,163.97 Date Paid: 8/22/2019 Parcel Number: 24-26-21-0110-00000-3230 '. ".CONTRACTOR.INFORMATION z -OWNERINFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607-5995 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,005 SQ FT -. APPLICATION.FEES' PLUMBING FEE 175.50 SEWER CONNECTION RESIDEW 2,090.00 ELECTRICAL FEE 263.25 WATER CONNECTION RESIDENT 1,010.00 MECHANICAL FEE 122.85 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,268.40 WATER METER RES 3/4" 473.78 PARK FEES SF 769.56 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 V Inspections Re' uired, FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. TRAC I NATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOtt CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I , Jacqueline Boges From: City of Zephyrhills Support <support@zephyrhilisfl.zendesk.com> Sent: Tuesday,August 27, 2019 12:06 PM To: Jacqueline Boges Subject: [Request received] 39684 Dawson Chase dr by#21669 EXTERNAL EMAIL ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/288837 ...................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Aug 27, 9:06 AM MST services for 39684 dawson chase dr by#21669 This email is a service from City of Zephyrhills Support . 1 Lennar Homes -39684 Dawson Chase Dr-2,005 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 2,005 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 225,863.25 FEE SHEET $ 1,170.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,268.40 ELECTRICAL: $ 263.25 PLUMBING: $ 175.50 MECHANICAL: $ 12222.8585 SUB-TOTAL $ 1,830.00 I TOTAL $ 1,830.00 SEWER: $ 2,090.00 1 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,957.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,163.97 PASCO COUNTY, FLORIDA Permit No. /6 Date Permitted Builder Name/Owner Name �g u n ew e Control#' County Par..cel No. Zq-Z4 L(-- 0tll 0-6060 SubDiv: )*da40,7 Address/Location 3 9 b 9V cba S Classiflcation/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z, Exempt [] Yes ❑ No How Determined Impact Fee Amount $. ,�7 ��Z.(1� Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7, 605. 2-8 (057) Moblle Home (058) Other Residential 23) Collection Fee Exempt d Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 76q. 6/i Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount - / _ RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 813-786-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received I I Phone Contact for Permitting 813 363 _ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A. Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 39684 Dawson Chase Drive LOT# 3230 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-3230 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR H ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION BLOCK FRAME = STEEL DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE LT/R SF 2009SQ FOOTAGE 1555 HEIGHT 1 Story Trl"1"1"'ITTrITI"1'T'1"TTI1T1"1"7�IT1"ITITrr'rITT'1"TT'ITITrI"1"T�IT�ITI"1"I� BUILDING $ n VALUATION OF TOTAL CONSTRUCTION ELECTRICAL re oC ® PROGRESS ENERGY Q W.R.E.C. AMP SERVICE PLUMBING $ q 9 MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION (LQ =GAS ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES I o -a- -N-1-��F-1-a•-F*F-1�--E-H-1-&4- F-H-1--1-1 1 1-1- -1-14-1--�1-H-I•-1-�1�-:-1-�Fu1�F-f-i-1-a-�1-CHI-I`-1--��1- BUILDER COMPANY I Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Address 4600 W.Cypress Ste.200 ampa,FL 33607 License# I CGC1518166 ELECTRICIAN COMPANY I Edmonson Electric, Inc. SIGNATURE F REGISTERED Y/ N I FEE CURREN Y/N Address 1034 Skipper Wad,T pa, FL 33613 License# I EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308,kfayoVf, FL 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 530 ayon , FL 34674-5308 License# I CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE F REGISTERED Y/ N FEE CURREN I Y/N Address 4211 Shoal Lin Ivd, Spring Hill, FL 34607 License# 1 CCC057991 1111111111111111 1111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets:of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. �Is4.4.1�1��1-d-1�1�1-r�1-.1-1•.I�i�4�--4.{�1���1-�1-1�1..4.1���1--{�1�1..4�4.1�4a��1-�4-E.L.1��1-P:�-1�-i�l..�a..��4.4.4.1� Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers ' Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I, certify,that.no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FI ANCING, CONSULT WITH YOUR LENDER OR AN ATT RNEY BEFORE RECORDING YOUR NOTICE OF CO CEMENT. FLORIDA JURAT(F.S. 117,03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affir )before me this Subscribed and sworn to(or a ed)before me this ca-Jul-i y by Ashlee Calla 2e-Jui-19 by Ashlee an Who is/are personally known t e or Who is/are personally known to me or has/have PFedue identification. entification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary tvped,printed or stamped Name of Notary typed,printed or stamped In, ----l�u'�N --- -- ' ,� ER,I(1,`>'lJI►1,tI01At:`�hW El, .tlol.tE',g1YW [`% � 4i�'�rcn°�P7fll�pf�tll�D77 - SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 323 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00'23'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE. PRELIMINARY DRAWING: ALL DATA SHOWN HEREON BASED ON THE l � THIS PLAN IS FOR PERMITTING PURPOSES ENGINEERING PLANS OF KIMLEY—HORN AND ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. o LEGEND: __�= PROPOSED DRAINAGE FLOW ,II = 10' UTILITY EASEMENT (00.00) = PROPOSED GRADE E-00.00 = EXISTING GRADE U NOTES: V) LOT GRADING TYPE = A PROPOSED PAD ELEVATION = FRONT SETBACK = 20' `GV SIDE SETBACK = 10' REAR SETBACK = 10' r PLAT O� L QG 72.75') BOUNDARY TRACT A HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) 2s. t N A ro�� SA�04 PLAT C 3: bra• QO 2 ya:' BOUNDARY !n ...........N.837o56,w JP(ttP,) \\ r ° LOT 323 \GO 38.64' �i Of Q' 3•. ON LOT AREA CALCULATIONS •_'0, LOT = 7310.69 SQ. FT. ��, •�4j LIVING AREA = 1556 ENTRY =_40 SQ. FT. GARAGE = 406__$q, FT. a pc`1 pc� COVERED LANAI = N/A—SQ. FT. C9 SQ. FT.PATIO = 23 CONC. DRIVE = 535 SQ. FT. LOT 322 00 q�9 A/C & CONC PAD = 9 SQ. FT. PRIVATE SIDEWALK = 28 _SQ. FT. IMPERVIOUS =_36 2597 __SQ — .S FT. 'fro TRACT A = SOD =_471_4___SQ. FT. G� HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) OFF LOT AREA CALCULATIONS RIGHT OF WAY 626.88 SQ. FT. ' DRIVE APRON _144 SQ. FT. �. PUBLIC SIDEWALK = 214—SQ. FT. SOD = 2§9 —SQ. FT. PLAT TOTALS BOUNDARY AREA =_Z _V_SQ. FT. DRIVEWAY 679 SQ. FT. SIDEWALK �2 SQ. FT. SOD =_4983 SQ. FT. CURVE RADIUS 1 ARC 1 CHORD BEARING I DELTA PROPOSED: C9 100.00' 33.44 33.29 N 52'20'36" E 19'09'43" C276 310.00 31.93 31.91 S 45'42 4s W 05'54 03 LOWEST FLOOR ELEVATIONS: C280 200.00' 1 20.60 20.59 N 464246" E 05'5403" 1 LIVING AREA: 74.16' DESCRIPTION: GARAGE AREA: LOT 323, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", ELEVATIONS REFERENCED TO AS RECORDED IN PLAT BOOK 079, PAGES 110 THROUGH NATIONAL GEODETIC VERTICAL 082, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. DATUM OF 1929. MEAN SEA LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101 C 0458 F EFFECTIVE DATE: 9 26 2014 Square Feet: 7310.69 t LENNAR HOMES LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POE W F= WOOD FENCE JOHN R.BEACH&ASSOCIATES,INC. yawn By: SMS SURVEYORS AND MAPPERS 911 WEST ST• PETERSBURG DRIVE Checked By: ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: aI: NOT VALID WITHOUT ORIGINAL SIGNATURE Data: PLOT PLAN 7 24/19 JBS KoD. /N AND THE RAISED SEAL OF A FLORIDA GN R DATE LICENSED SURVEYOR AND MAPPER JOHN R. EACH Revisions: FLORIDA R G. LAND SURVEYOR No. 2984 LB 4493 JEFF M. RTLEY _BBOFESSZONAL SURVEYOR & MAPPER No.7123 D Q' r Single Family Dwelling Plan Review Comments 1. REE; shall be a minimum of 8-' above the road elevation-and an engineered site plan. 2. Lots shall be-graded to comply with R401.3 'of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. .Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered.and.marked at time of first inspection. & All N.D.A.requirements shall be met: 9-. .No electric',plumbing mechanical, or framing shall be covered without an inspection_ .and_ approval first. 10: All Garages,shall comply with section R302.6 of the F.B.C. (Fire Separation).. 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by:approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1. 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313-.1 of the.F.B.C. 16:All glazing requirements are to be in accordance.with R30&.4 of the RB:C. 17. All means of egress are.to be in accordance with R311 of the F.B.C.. 18. ``Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 2-1. All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all underground:plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 21 Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10 feet around the structure. 25. R403.5.3Hot water pipe insulation Insulation-for lint water pipe with a.minimum thermal resistance-(R-value) of R-3 shall be applied to the following: Piping 31, inch (19.1 mm)and larger in nominal.diameter.. Piping serving more than one dwelling unit. Piping located outside the conditioned space: Piping from the water heater to.a distribution manifold. Piping located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems: 25. Blower door test shall be provided before C.O: 26.A cony of the energy cacls shall be with-permit at all times: 27 Conn of finqtihsqhgdoh rep6it-shall be provided with Permit before fnab 28.No fence, Pool or screen enclosure .is issued with ahis pern:i F.F.E:-Finished Floor Elevation F.B.C- Florida Building Code 6a'Edition R.O.W:-Right of Way A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551 B1 sf ADS Carrier VW Builder Name: Lennar Homes 0323 Street: 39684 Dawson Chase Drive Permit office: City of Zephyrhills City,State,Zip: ,FL, Permit Number: rjj 0 Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (1555.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.33 55.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.55 33.33 ft2 12.Cooling systems kBtu/hr., Efficiency -SHGC: SHGC=0.34 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 16.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.262 14.Hot water systems- 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 EF:0.950 9 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 49.77 PASS Total Baseline Loads: 50.85 1 hereby certify that the plans and specifications covered by Review of the plans and 041 S ?� this calculation are in compliance with the Florida Energy specifications covered by this 1+ Off, Code. calculation indicates compliance with the Florida Energy Code. rfr,lr; ,'o;; PREPARED BY: DayP Before construction is completed DATE: this building will be inspected for a compliance with Section 553.908 I hereby certify that this building,as d s' ned, is in compliance Florida Statutes. 1 �� with the Florida Energy Code. COD OWNER/AGENT: JUL 3 1 20 BUILDING OFF'`�I DATE: DATE: �lJt7 L o L . - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct.leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 4/1 21201 9 2:46 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551 B1 sf ADS Carrier VW Builder Name: Lennar Homes 0323 Street: 39684 Dawson Chase Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.33 55.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.55 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 16.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.262 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 49.77 PASS Total Baseline Loads: 50.85 I hereby certify that the plans and specifications covered by Review of the plans and lt-tSE STAT this calculation are in compliance with the Florida Energy specifications covered by this ti0' gz Code. calculation indicates compliance ��.,, ''} AV with the Florida Energy Code. nIt's PREPARED BY: Before construction is completed t, DATE: this building will be inspected for - compliance with Section 553.908 hereby certify that this building,as de ' ned, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: �8 � 20.19 BUILDING I I tr," DATE: DATE: �� - Compliance requires certif' ation by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation.Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 4/12/2019 2:46 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1551 B1 sf ADS Carrier VW Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1555 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Vinyl windows CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1555 12440 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1555 12440 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R.-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 134 ft 0 1555 ftz ---- 0.3 0 0.7 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1684 ftz 0 ftz Medium N 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1555 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1555 ft' 0.11 Wood 4/12/2019 2:46 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 8 160.0 ft' 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 432.0 ft' 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft' 0 0.600000 0 5 N=>NE Garage Frame-Wood Main 11 19 8 8 157.3 ft' 0.23 0.01 0 6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ft' 0.23 0.01 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft' 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ftZ 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft' WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 16.0 ft' 1 ft 0 in 4 ft 2 in Drapes/blinds None 2 E=>SE 2 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft' 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft' 1 ft 0 in Oft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.55 0.34 N 33.3 ft' 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft' 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 408 ft' 408 ft' 40 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 . 1 Wholehouse Proposed ACH(50) .000356 1451.3 79.68 149.84 .1303 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 4/12/2019 2:46 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS —Supply-- —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 311 ftz Main 77.8 ftZ Proposed Qn Main —cfm 62.2 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr Ma X Jun X Jul Au Se Oct Nov Dec Heating lX Jan Feb �MarAprfiMayr lJun 4 Jul Aug �Xj SepfOct NNov X Dec Ventin [ Jan Feb X Mar [X A r [ Ma Jun [ Jul Au Se [X Oct Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftZ Oft 0.3 1st Floor Default 8 Ibs/s .ft. 0 ftZ Oft 0.3 2nd Floor 4/12/2019 2:46 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 1555 d)Room unit/PTAC EER e) Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.400 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.262 14. Heating system: Capacity 24.0 c)Area 7c. 104.3 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c)Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f)Other 9.00 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 15.Water heating system c) Concrete,raised(R-value) 9c. a)Electric resistance EF 0.95 b)Gas fired,natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a)Ceiling fans a)Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c)Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11 d. No e)Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. I certify that this home has complied with the Florida Bu'ding Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)' this home before final inspection.Otherwise, a new EPL display card will be completed based on installed de compliant features. Builder Signature: Date: 08/01/19 Address of New Home: 39684 Dawson Chase Drive City/FL Zip: FL Zephyrhi11s, FL 33540 4/12/2019 2:47:21 PM EnergyGauge®USA 6.0.03(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Analysis Job: 1551B1sf ADS CarrierV W rightsofts 9 w Date: 7/30/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For. Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa IntemationalAP,FL,US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD(°F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(grAb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Sem�tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh %of load Walls 5.0 8281 34.7 acts Glazing 21.5 2813 11.8 nfiltration Doors 19.8 740 3.1 Ceilings 1.3 1950 8.2 Walls Floors 3.7 5815 24.4 Infiltration 1.9 2372 9.9 Duds 1901 8.0 Piping 0 0 , Floors Humidification 0 0 Ventilation 0 0 Adjustments 0 Glaang Total 23873 100.0 Doors Ceilings Component Btuh/ftz Btuh %of load Walls 2.4 4025 20.5 Glazing 46.6 6101 31.0 Wall Internal Gains Doors 15.5 580 3.0 Ceilings 1.7 2697 13.7 Floors 0 0 0 Infiltration 0.4 531 2.7 ucts Duds 2200 11.2 Ventilation 0 0 Infiltration Internal gains 3520 17.9 Blower 0 0 Glazing Adjustments 0 Ceilings Total 1 1 19654 100.0 Doors i Latent Cooling Load=2292 Btuh Overall U-value=0.101 Btuh/f?--°F Data entries checked. wrightsoft^ 2019-Jul-30 07A6:56 Right-Suite®Universal 201919.0.07 RSUD5714 page 1 ...equipment\1551sfADSVW Tampa 2tonCarrierrup Calc=MJ6 Front Door faces:NW Project Summary W Job: 1551B,sfADSCarrierV wrightsoft@ Entire House Bye: DaVe2o,s Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: Vinyl windows Design Information Weather: Tampa IntemationalAP,FL,US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70, °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21972 Btuh Structure 17454 Btuh Ducts 1901 Btuh Ducts 2200 Btuh Central vent(0 ctm) 0 Btuh Central vent(0 ctm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23873 Btuh Use manufacturers data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19654 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality SemHtight Fireplaces 0 Structure 1902 Btuh Ducts Central vent(0 cfm) 390 Btuh Heatingg Cool'ngg (none) Area(ft� 1555 1555 Equipment latent load 2292 Btuh Volume(fn 12700 12700 Air changesmour 0.26 0.14 Equipment Total Load(Sen+Lat) 21946 Btuh Equiv AVF(cfm) 55 30 Req.total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER,15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47-F Latent cooling 3600 Btuh Temperature rise 27 °F Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 Cfm Air flow factor. 0.034 dmBtuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point=32°F Backup:n/a n/a Input=0 kW, Output=0 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk wrightsoft^ Rght-Suite®Universal201919.0.07RSU05714 2019-Ju13007:age 1 ` Page 1 ACCA ...equipmenfl1551sfADSWV Tampa 2tonCarrierrup Calc=MJ8 Front Door faces:NW Manual S Compliance Report Job: 1551B1 sfADS Carrier VW +�- wrightsoft' Date: 7/30/2019 Entire House By: Dave Bayonet Plumbing Heating and Air Project • e For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91 XF Sensible gain: 19654 Btuh Entering coil DB: 75.7°F Outdoor designWB: 77.3°F Latent gain: 2292 Btuh Entering coilWB: 62.8°F Indoor design DB: 75.0°F Total gain: 21946 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 104%of load Latent capacity: 3600 Btuh 157%of load Total capacity: 24000 Btuh 109%of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 23873 Btuh Entering coil DB: 69.6°F Indoor design.DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18304 Btuh 77%of load Capacity balance: 32 °F Supplemental heat required: 5569 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 800 crm Output capacity: 0 kW 0%of load Temp.rise: 0 °F Meets a0 requirements of ACCA Manual S. wr.ightsoft- 2019-Jul-30 07A6:56 Right-Suite®Universal 201919.0.07 RSU05714 e1 Pa J+C ...e ui ment11551 sfADS WVTa g q p Tampa 2ton Carriecrup Calc=MJS Front Door faces:NW PLOT PLAN SKETCH ONLY SEC. 24 , TWP. 26 S, RNG.21 E. NOT A BOUNDARY SURVEY LOT 323 HEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00'23'02"E PASCO COUNTY, FLORIDA. Do NOT SCALE THIS PRINT.DIMENSIONS AND NOTES TAKE PREFERENCE. PRELIMINARY DRAWING: THIS PLAN IS FOR PERMITTING PURPOSES N ALL DATA SHOWN HEREON BASED ON THE ONLY,NOT FOR CONSTRUCTION,VERIFY ENGINEERING PLANS 01 KIMLEY-HORN AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ASSOCIATES,INC.,PROVIDED BY LENNAR HOMES. LEGEND: __—-PROPOSED DRAINAGE FLOW 10*UTILITY EASEMENT (00.00)=PROPOSED GRADE E-00.00=EXISTING GRADE NOTES: LOT GRADING TYPE-A PROPOSED PAD ELEVATION FRONT SMACK-20' SIDE SETBACK= 10' REAR SETBACK=107 LAT 7275') BOUNDARY c; TRACT A 71DDEN RIVER PHASE ONE A, T BOOK 74,PAGES 101-121) 70 0 n PLAT BOUNDARY 41 V RM(P) ...... .......... LOT 323 ON LOT AREA CALCULATIONS 10 LOT -_2110-6-9-SCL FT. LIVING AREA = 1556 SQ.FT. 4:, ENTRY 40 —SQ.FL n.. GARAGE = 406 Q.FT. COVERED LANAI = N A Q.FT. - C-7 LOT 322 PATIO - 23 0,FT. 0 CONC.DRIVE .0 FT. 0. A/C&CONC PAD 9 sQ.FT. PRIVATE SIDEWALK = 28 Q.FT. IMPERVIOUS —1597 --SQ.Ft TRACT A SOD 4714 SQ•FT. HIDDEN RIVER PHASE ONE A (PLAT BOOK 74.PAGES 101-121) OFF LOT AREA CALCULATIONS RIGHT OF WAY -__626.5A_SO.FT. DRIVE APRON ---144 SQ.FT. PUBLIC SIDEWALK 214 SQ. FT, SOD , = 269 SQ. FT. PLAT TOTALS BOUNDARY AREA - ZUl§LSQ.FT. DRIVEWAY 679 c0.FT. SIDEWALK = 242 S0.FT. SOD = 4983 cq,Fr. CURVE 1 B O%S 1 MC I CHORD I OWING I DELTA IL - PROPOSED: Do OD. 33,44' 133.29- 1 N 5720- E I 19'G9-43- r27r I 31moa 1 31.93 1 31.91 1 5 iYE42-46.W I W5403- LOWEST FLOOR ELEVATIONS- - C2SD 2moo* 1 2MST 1 2"9' 1 N 45'42.46-E I 05'54'n3' LIVING AREA: 74.16' DESCRIPTION: GARAGE AREA: TO LOT 323, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", ELEVATIONS REFERENCED NATIONAL GEODETIC VERTICAL AS RECORDED IN PLAT BOOK 079. PAGES 110 THROUGH DATUM OF 1929. MEAN SEA 082, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: X' COMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 9/26/2014 Sq..ro Feet: 7310.69 :h LENNAR HOMES LEGEND: (C)-CALCULATED DATA,(D)-DEED DATA,(M)-MEASURED DATA, (P)- PLAT DATA, -E- CENTERLINE,A/C-AIR CONDITIONER,B/C- BACK OF CURB,C/S- CONCRETE SLAB,CH-CHORD.CHB-CHORD BEARING,CLF-CHAIN LINK FENCE,CONC=CONCRETE,COY.- COVERED,E/P-EDGE OF PAVEMENT,ESM'T= EASEMENT, F/C- FENCE CORNER, FCM= FOUND CONCRETE MONUMENT,FIP-FOUND IRON PIPE,FIR-FOUND IRON ROD,FN&D= FOUND NAIL&DISK.FPP-FOUND PINCHED PPE.LFE-LOWEST FLOOR ELEVATION,MAS­ MASONRY,OR- OFFICIAL RECORD BOOK, PB= PLAT BOOK,PCP-PERMANENT CONTROL POINT,PRM-PERMANENT REFERENCE MONUMENT,R/W-RIGHT OF WAY,R-RADIUS,SIR-SET 1/2"IRON ROD&CAP No. 4493, SN&D=SET NAIL&DISK, TBM- TEMPORARY BENCHMARK, UTILITY POLE.W/F=WOOD FENCE Drown By. JOHN R.BEACH&ASSOCIATES,INC. OSMS t SURVEYORS AND MAPPERS Ch..k.d Br. 911 WEST ST.PETERSBURG DRIVE JRS ONE OLDSMAR,FLORIDA 34677 WAY (513)854-1276 FAX(.13)855-8370 scoi.: NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 7/24/19 JBS AND THE RAISED SEAL OF A FLORIDA XG R. EACH DATE LICENSED SURVEYOR AND MAPPER . EA )�N R EACH R Revisions: ---- 74 JA I%MA 0 SURVEYOR No.2984 LB#4493 [=&WTLEY ZONAL SU RVEYOR& MAPPER No.7123 Jacqueline Boges From: Jordon Davis (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com> Sent: Tuesday,August 27,2019 6:33 PM To: Jacqueline Boges Subject: [FATHOM] Re:39684 Dawson Chase dr bp#21669 EXTERNAL EMAIL ##- Please type your reply above this line -## Your request (#288837) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephyrhillsfl.zendesk.com/hclrequests/288837 ................ ............-.1-1...........--...............--...............--............ ............... ............-1-................-...................................-..................................--..............---................................................................ .................. Jordon Davis (City of Zephyrhills Support Aug 27, 3:3 2 PM MST The account has been added and services are currently being mapped. The account number is 0000889145-003133979 Best Regards, Jordon I FATHOM Support ..................................-...............-..................................-............. .......................................................... .............................. ................................................................................. ............................. Jacqueline Boges Aug 27, 9:06 AM MST services for 39684 clawson chase dr bp#21 669 This email is a service from City of Zephyrhills Support INSTR#2019142633 OR BK 9960 PG 2042 Page 1 of 1 08/22/2019 01:10 PM Rcpt:2083790 Rec:10.00 OS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Permit No. V �L Parcel ID No 24-26-21-0110-00000S230 NOTICE OF COMMENCEMENT state ar Florida county of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,. the following Information is provided in this Notice of Commencement 1. Description of Property. Legal HIDDEN RIVER PHASE 2 PB 79 PGS 102-110 LOT 323 . SbeetAddress: 39684 Dawson Chase Drive Zephryhiils FL 33541 2. General Description of Improvement Single Family Residence!Pool/Screen Enclosure/Fence 3. owner information: Lennar Homes,LLC. Name 4600 W Cypress I.Ste 200 Tampa FL.33607 Address City State Interest In Property. Name of Fee Simple Titleholder. NIA Of other than owner) _ Address City / State 4. Contrerdor. Lennar Homes,LLC Name 4600 W Cypress St,Ste 200 Tampa FL 33607 Address City state Cantractors Telephone No.: 813.574.5700 5. Surely.` N/A Name Address City State Amount of Bond:$ Telephone No.: 6. Lender. N/A . Name Address city State Lender's Telephone No,: ' 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served ai provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes.LLC Name 4600 W Cypress St,Ste 200 Tampa FL 33607 Address City State Telephone Nrmrber of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of_ to receive a copy of the Uenoes Notice as provided In Section 713.13(1)(b),Flodda Stehrtes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement is one yearfrom the date of recording unless a different date Is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MAST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owners Authorized Ofliaer/Director/PartnedManager Vice President ? Signatory's Title/Office The foregoing Instrument was admaMedged before me thin 25 day of July ,by leA'2- ' Steve Robert Smith as Vice President (type of authod r,busies,attorney in fads for Lennar Homes.LLC (name of party on ohs rpm insbmrrentwas executed). Personalty Known N QH Produced Identification❑ Notary Sign re Type of Identification Produced Name(Prhd) lissa Holleran Verificationretrue t pursuant to Section n ledge,and bell Statutes. Under penalties of pert Ldecla eve read the foregoing and fhnt the facts stated ur - - It are tree to Me best of my knowledge and ballet ELIEMAKHOLl.EM _. Signature of Natural Person Signing Above - Gtemllr>dmtfFF7 ---- -wpdata/bdbrs form ,O iTM11ryFYhrgrrw100J�7gu gili ';DA,COUNTY OF PASCO "ki E OF FLOr6 PPS IS 1*0 CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT r.)N PILE OR OF PUBLIC RECORD IN THIS OFFICE WITNESS MY HAND AND OFFICIAL SEAL THIS DAY OF e2,L,—,9 2 Ot"A CLEF. MPTROLLER BY DEPUTY CLERK i � . Y Building and Construction Services(BCS)JL I XS C - * JI COUNTY FLORIDA , Blower or Test Report Form- ��"}I't.ht St>.nc_��_�,. 1'itst��,:�'r 1't_.3{_t.�. Property Address: Unit#: 6 Permit#: Testin an N e: Test Date: Te r Name: &3 r Tester Cert Cont t ne: h 76 402.4.1.2 Testing.Building envelope airtightness shall be demonstrated by Section 402.4.1.2 } The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes k per hour. Testing shall be conducted with a blower door at:a pressure of 0.2 inches w:g. (50 Pascals).As required by the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test r shall be signed by the party conducting the test(including Agency Name) and provided to the Building Official prior j. to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled y penetrations of the building thermal envelope. During testing:(check to verify condition met) Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended p Y G weather-stripping or other I: t' ®Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond f {. intended infiltration I Interior doors,if installed at the time of the test,shall be open Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed Heating and cooling systems,if installed at the time of the test,shall be turned off J Supply and return registers,if installed at the time of the test,shall be fully open I } Va Building volume(ft3) _ Q50 Airflow at 50 Pascal(CFM) - l ACH5o Air changes per hour at 50 Pascal Qsa x 60_Vb J . ACHso (3.0ACH minimum) ( Pass I Fail ❑ ❑Outside Air mechanically introduced to space(less than 3.0 ACH) I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Ener . Code requirements in accordance with Section R402.4.1.2. atu f Tester Date i l ir Jet Stream° Ultra Mowing Wool Insulation kNAO Attic and Cavity Wall Card 66�6 we energy ' Batts and Blankets -Equipment Required When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a camfgated hose with a minimum W internal comigathm,a minimum length recommendations,Knauf insulation baits and blankets will of 151Y.Coils in the hose should not be less than 3V in diameter.Acceptable material feed late is 5-35 Ibstaimute.Recommended feed' provide the foil R-vakd rate Is 15.25 ibstminuie. * _Minimum Thickness Thermal Performance'(Sidewall and Attic Application) ` insulation te5i5ta0G0 Installedi u The stated thermal resistance(R-Value)is provided by installing In accordance with the manufacturer's instructions.Failure to install the - a ue _ _ To obt10 on Insulation,than: of d required number of tags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label (R-Valuo)of: not be less than: will result in lower installed R-values.Field blending of the product with other loose fill insu_(atiom is not recommended by the manufacturer. R-49 1335" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. R-38HD _ 10.25" R=38 12.00" R-Vaiue* gags per 1000 SF Maximum Net Minimum To obtain an The number of bags Coverage per Bag Weight per SF R 3QHD $•25"' insulation per 1,000 square feet Contents of this The weight per square R-30 10.00, cavity resistance of net area should not bag should not teat of installed insulation I R-26 9.00" Framing Depth_ of: Density be less than: cover more than: should not he less than: I R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft.. 16A bags 61.0 sq.ft. 0.525 lbs. { R-21HD 5.50" 2"k 6" 6.60" R-23 1.8 lbs,/cu.ft. 25:8 bags 38.8 sq.ft. 0.825 lbs. R-19 6.25"** R-15HD 3.60" 2"x 8" 7.25" R-31 1.8 Ibs:/cu.ft. 34.0 bags 29.4 sq.ft. 1,088 lbs. R-13 3.50" 2"x 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft 1.388 lbs. R-11 3.50" R means resistance to heat flow The higherthe R-value,the grealerthe insulating pourer.To get the marked R-value,it is essential that ibis insulation be Installed proraly. R-8 2.50" R-10 in a UT cavity.ConConns to ASTM C 655 and federal Open Attic Application Bag Net Weight-Nominal 32 lbs_.,Minimum 31 lbs. Specification HH-"21F, Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** To compensate for framing members,the number of bags per The number of bags! Contents of this The weighuSP Thickness Contents of this 1,000 sq.ft of area to be insulated should be as SheWt}below. R-Va ve* 1,000 SF of net area bag should not of installed Installed insulation bag should i To obtain an insulation should not be less cover insulation should not should not be less not cover more Bags/MSF BagslMSF resistance(R-Value)of: 'than: more than: be less than them, than: j Joist 169 O.C. 24"O.C. R SQ 29.7 33.6 SF 9521bs. 19. " 19. R-Value Dimensions Framing Framing 750 750" I 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16375" 16.375" R-60 M 28.9 .29.1 R-44 20.9 47.8SF .670lbs. 14.875" 14.875" 2x8 28:6 :28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" 2x4 .23.0 • 23.2 R-30, 13.6 73.3 SF A37.Ibs: 10.375" 10:375" R=40 2x6 22.7 22.9 R-26 11.8 85.0 SF 377 lbs. 9.125" 9.125" 2x8 22.4 22.7 2x4 20.4 20.6 R-22 9.8 102.2 SF .313 lbs. 7.750" 7.750" R-44 26 20.1 20.3 R-19 8A 119.3 SF' .268 his. 6.750" 6.750" ; - i .2x8 19.8 20.1 R-13 5.7 175.3 SF .1$31bs. 4.750" 4.750" 2x4 17.3 17.4 R-11 4.7 210.8SF .152lbs. 4.600" 4.00Q" 1148 2x6 17.0 17.2 &y Netweigtd-RcuriM 320s.,Hrior=31 ets. 2x8 16.7 17.0 Coma,eaidirWalla5anda3vM1e&'. dWnl;avo ncbrmgnadrineminird9ear4iIrg�etpe*,2.0p &pressueadISTd3nematy<oRuga nose ThB product mnlanu to Im pe br.00 requ-aemenls 0ASTN C 767,Type Lad raxeCed Federal 5pedficaBon HH+1030B,Type 1.Class S.R-values are determined in eawdsnce w1h C 687 and C 518, i 2x4 13.2 13.3 '*Wmaa mdsta�mneatkxThet meR-va;e:ftgreaterme:mtarkrgpm�TcgalNamrWR.vote.abemmUeW+tvs'orb"onbeinstaSaa ty.xyadoayo,isett•gettnitrd. R-30 26 12.9 13.1 tiaras end beau Them oarefuty.lastmctions do not coma wM this paclmge. _ "eased onTNrd Pady2yease0fmgsNdy,lietseddedseek�nefdovera 24•yeatpeyiodwwl4 be iowssitorless.ws amoantoiseengisttaes:n�y izs7 sfexrd.Te�sataie,tteiatared and tolled 2x8 12.6 12.9 05doessesaee0ectvelyhesame i 2x4 11.3 11.4 vdu•ttaSeu"aregsaredta�matotuniscot R-26 2x6 11.0 11:2 Builder's Insulation Statement j 2x8 10:8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness 1142 2x6 9.1 9:3 Attic Area R- 56 at_ / Inches l 2x8 8.8 9•1 Sloped,Ceilings R- at Inches 2x4 7.9 8.1 Walls R- at Inches R-19 2x6 7.7 7.9 Floors(over en unheated craw]space) R- at Inches 2x8 7.4 7.7 2x4 5.3 5A Crawl Space Perimeter R- at Inches R-13 26 5.0 5.2 Date installed/2"ZO f? 2x8 4.8 5.0 Blown insulation has tieen installed in conformance with the above recommendations to provide an R-value of 2x4 a.3 4.4 R- Jo using /(„ .bags of this insulation to cover�,[(1 _square feet of area R-11 2,6 1 4.1 4.3 at a minimum thic o 2x8 3.8, 4.1 j I{ 1 CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRE �., DATE' PERMIT# cL 1,2 ar-) 2 /� THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or othermaterial,until the proper Inspector has had ample time to approve 780ZOOOR RE-INS- ECTION the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR