Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19-20676
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20676 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20676 Address: 7422 GALL BLVD Permit Type: RE-ROOF ZEPHYRHILLS, FL. Class of Work: ROOF REPLACEMENT Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-07200-0011 Improv. Cost: 348,450.00 OWNER INFORMATION Date Issued: 1/28/2019 Name: PROVEST TOWNVIEW LLC & MISSION H Total Fees: 2,677.50 Address: P.O. BOX 515 Amount Paid: 2,677.50 HUDSON NY 12534-0515 Date Paid: 1/22/2019 Phone: 518-719-0100 Work Desc: REROOF TPO CONTRACTORS APPLICATION FEES JOLLY ROOFING AND CONTRACTING CO REROOF COMMERCIAL 2,677.50 Al DRY IN ROOF IN P Ins ections Re uired TAPE JOINTS ROOF INSP FINAL REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. O TRAC OR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780.0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting -rrrrr _ rrn Owner's Name I �tQ�V CS 1 �O utJ;�\S(rC.Iu Owner Phone Number Owner 3 s Address es C' V S S. a��+V o 5pr( Owner Phone Number Fee Simple Titleholder Name cJA" 1".r A S f-,36-4 Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS A L y(r W N Q 1 LLS �L 3 J�(I LOT# SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/AL � SIGN = = DEMOLISH INSTALL EPAIR PROPOSED USE = SFR Q COMM F� OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK &0/Af akCJfi -�I/�lJ/O��° ,Q tpy7r/�L'xt STIr✓&-/=Dor lds AL-um; ow rJ,o fal Ir'(�a BuiLDINGSIZE I DOt7 S 1="' SQFOOTAGE C{I DO HEIGHT =BUILDING $3 q (�1 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ Lv" AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. =PLUMBING is =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION (D- =R00FIN6) co =GAS = SPECIALTY = OTHER nn U C + FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA AYES NO G/ C'{ BUILDER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREA LXIN Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN I Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREA Y/N Address License t) MECHANICAL COMPANY SIGNATURE REGISTE o I Y/ N FEE CURREn Y!N Address n� License# L©�Tr�►C.Tt2/ OTHER COMPANY Jo f�DO-IsIG +- r/�RAcYIa/EG �Dr�r SIGNATURE REGISTERED Y/ N FEECURREr Y/N Address 11 Ad VC Ia ) ;T 330i7 License# C— -131-11 6 111111111111 1111 tllllllltllllllllllllllllllllllllllllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans wl Slit Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/iarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stomlwater Plans w/Silt Fence installed, San"Facilities S 1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. ' IIitlJltt . . . tt ' Illllitili.iillltit.l ' Direetions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement IS required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Rercofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to'deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor-or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not Involve a certificate of occupancy or final power release,the fees must be paid prior to permit.issuance. Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT. I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addeessing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone"A in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools,air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.1y17.0_3)Q OWNER OR AGENT ^ CONTRACTOR Subecdb�d andvwom to(or afrymedLbefo me ti7(q beaand to(or re me is I'J �dG[Cful�+� Yr _ r1 ,111111l11!! Who is/are Personally known to me o d e I n m or hash produced ``�%:N, LE$�C�F C/ as i entification. UV'"� ` ' STATE otary bile Notary Pukllc OF TENNESSEE Cibmmission N M -Cq mission ireS Commissipn NOTARY Q , ° ber-1- ,-2021 0�� slop Expfres; PUBLIC N orNolerytype ,pnnedors"'HEW J.GRIESEML- erne of Notary typed,p nedcrsa 1 � �y�•. NOTARY PUBLIC-5TA"I E OF NEW PORK .1le NO.o2GR6132356 QUALIFIED iN r:OLUtv161A COUt'ITY a-p C0h4MISSI0N EXPIRES FEBRUARY 25,20_ Cr) T=A -ING ._4rl+aN . .. PROPOSAL PROPOSAL SUBMITTED: qoy eSi -T3w N Zx ;, L„L_ DATE:10/16/1a N Y % .X S 3 REVISED ATTN:HARRIS COHN RE:ZEPHYR HILLS CENTER--RURAL KING ROOF REPLACEMENT IWe Propose To Furnish And Install The Following Items:APPROX 91,0001 SF 1) REMOVE ALL THE BALLAST ROCK FROM ROOF AND DISPOSE OF OFFSITE 2) REMOVE AND HAUL AWAY ALL EPDM MEMBRANE AND FLASHINGS 3) PROVIDE/INSTALL NEW PRESSURE TREATED WOOD NAILERS TO MATCH NEW INSULATION HEIGHT 4) PROVIDE/INSTALL I"POLYISO INSULATION MECHANICALLY ATTACHED PER 20 YR WARRANTY SPECS 5) INSTALL 60 MIL TPO MECHANICALLY ATTACHED SYSTEM WITH HD FASTENERS PER 20 YR WARR SPECS 6) FLASH ALL PENETRATIONS AND WALLS PER 20 YEAR'WARRANTY SPECIFICATIONS 7) PROVIDE NEW 24GA PRE-FINISHED GALV COPING,DRIP,GUTTERS AND DOWNSPOUTS 8) PROVIDE A 20 YEAR"NO DOLLAR LIMIT"MANUFACTURERS ROOF WARRANTY 9) PROVIDE A JOLLY 5 YEAR WORKMANSHIP WARRANTY TOTAL COST--$348,450.00 ADD$6.50 PER SF TO REPLACE ANY WET OR BAD EXISTING INSULATION,HAUL WAY DEBRIS ADD$7.50 PER SF TO REPAIR ANY BAD DECKING,CLEAN AND PAINT ON RUST INHIBITOR ADD$11.50 PER SF TO REMOVE AND REPLACE ANY ROTTEN METAL DECKING ➢ FURNISH(20)YEAR MANUFACTURERS WARRANTY ➢ 1,1VE EXCLUDE FROM THIS PROPOSAL' PLYWOOD SHEETING, THRU WALL PLASHING, COMPOSITE PANELS, ROOF CURBS AND WALL PANELS WE PROPOSE hereby to furnish materials and labor to complete work in accordance with above specifications, for the sum of: THREE HUNDRED FORTY-EIGHT THOUSAND,FOUR HUNDRED FIFTY *this price Includes all taxes related to this project ***NOTE DINE TO CON71NUJIVOPR=INCREASES, TAYS PROPOSAL ZS ONLY GOOD FOR 30 DAYSFROMAROST DATE ** Authorized Signature GI,ENN CONWAY All materials are guaranteed to be'as specked. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders,and will become an extra charge over and above the estimate. All agreements are contingent upon strikes,accidents or delays beyond our control. Owner is to carry fire,tornado and other required insurance. Our workers are fully covered by Workmen's Compensation Insurance.It is also agreed that in case of default of payment and this note is placed in the hands of a collector or an attorney for collection,all collection fees,attorney fees,costs,and all other expenses will be paid by the undersigned. ACCEPTANCE OF PROPOSAL-The above prices,specifications and conditions are satisfactory.and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Date of Acceptance: I O- 30—I$ Signature S cE.L 615-879-9065 www.iolivroofina.com ;Icy �b15i 832-1�._�; x (6;ic:; 4 6-Ys a " conwa oll roofin corn PROPOSAL PROPOSAL SUBMITTED; HARRI rOGN4 Q ON gs j '—`01J-7" eJL9 L--L- DATE:10116/18 155 P.o Go* sls - l-t�d scr►, ti� %as 3y REVISED ATTN:HARRIS COHN RE:ZEPHYR HILLS CENTER--RURAL KING ROOF REPLACEMENT IWe Propose To Furnish And Install The Following Items:APPROX 91,000,SF 1) REMOVE ALL THE BALLAST ROCK FROM ROOF AND DISPOSE OF OFFSITE 2) REMOVE AND HAUL AWAY ALL EPDM MEMBRANE AND FLASHINGS 3) PROVIDE/INSTALL NEW PRESSURE TREATED WOOD HAILERS TO MATCH NEW INSULATION HEIGHT . 4) PROVIDE/INSTALL I"POLYISO INSULATION MECHANICALLY ATTACHED PER 20 YR WARRANTY SPECS 5) INSTALL 60 MIL TPO MECHANICALLY ATTACHED SYSTEM WITH HD FASTENERS PER 20 YR WARR SPECS 6) FLASH ALL PENETRATIONS AND WALLS PER 20 YEAR'WARRANTY SPECIFICATIONS 7) PROVIDE NEW 24GA PRE-FINISHED GALV COPING,DRIP,GUTTERS AND DOWNSPOUTS 8) PROVIDE A 20 YEAR"NO DOLLAR LIMIT"MANUFACTURERS ROOF WARRANTY 9) PROVIDE A JOLLY 5 YEAR WORKMANSHIP WARRANTY TOTAL COST--$348,450.00 ADD$6.50 PER SF TO REPLACE ANY WET OR BAD EXISTING INSULATION,HAUL WAY DEBRIS ADD$7.50 PER SF TO REPAIR ANY BAD DECKING,CLEAN AND PAINT ON RUST INHIBITOR ADD$11.50 PER SF TO REMOVE AND REPLACE ANY ROTTEN METAL DECKING ➢ FURNISH(20)YEAR MANUFACTURERS WARRANTY ➢ WE EXCLUDE FROM THIS PROPOSAL' PLYWOOD SHEErINC, THRU WALL FLASHING, C0?8IPOSITE PANELS, ROOF CURES AND WALL PANELS WE PROPOSE hereby to furnish materials and labor to complete work in accordance with above specifications, for the sum of: THREE HUNDRED FORTY-EIGHT THOUSAND,FOUR HUNDRED FIFTY *this price Includes all taxes related to this project ***!VOTE DUZ TO COJVTIIVU MG PRFCSl/VCRML9KS, TBIS PROPOSAIL ZS ONLY GOOD FOR 30 DAYSFROMABOVFDATE. ** Authorized Signature GLENN CONWAY All materials are guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders,and will become an extra charge over and above the estimate. All agreements are contingent upon strikes,accidents.or delays beyond our control. Owner is to carry fire,tomado and other required insurance. Our workers are fully covered by Workmen's Compensation Insurance.It is also agreed that in case of default of payment and this note is placed in the hands of a collector or an attorney for collection,all collection fees,attorney fees,costs,and all other expenses will be paid by the undersigned. ACCEPTANCEOF PROPOSAL-The above prices,specifications and conditions are satisfactory and reby accepted. Youare authorized to do the work as specified- Payment will be made as outlined above- S Date of Acceptance: IO- 30—l S' Signature ceu 61"79-9D65 www.'oil roofin .com ,61&.1 832- ux td l ciconwav0iolivroofinci.com City of Zephyrhills BUILDING PLAN REVIEW COMMENTS J6�� ,�^ Contractor/Homeowner: d Date Received: ys Site: 7 D Permit Type: � �� 4 Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ r This comment sheet shall be kept with the permit and/or plans. Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, �r'i re St O ri e TECHNICAL INFORMATION SHNALELECTR1ccoD�, HE CITY OF ZEPHYRHILLS BUILDING PRODUCTS UltraPlyTM TPO Membrane r • Item Description Item Number T A 1 Roll INL-VIE i DATE E .��N ', 1019Various CITY OF ZERMYRFM - PLANS EXAMINER Meets or exceeds ASTM D 6878. Product inf• • Description: Firestone UltraPlyTm TPO is a flexible Thermoplastic Polyolefin roofing membrane that is produced with polyester weft- inserted reinforcement. UltraPly TPO membrane meets or exceeds all re uirements for ASTM D 6878 Specification. This heat weldable TPO membrane is available in 45 mil (1.14 mm) and 60 mil 1.52 mm thicknesses. This reflective membrane is suitable for a variety of low-slope applications. Method of Application: 1. Substrates must be clean, dry, smooth, and free of sharp edges,fins, loose or foreign materials, oil, grease, and other materials that may damage the membrane. 2. All roughened surfaces that can damage the membrane shall be repaired as specified to offer a smooth substrate. 3. All surface voids greater than 1/4" (6.3 mm)wide shall be properly filled with an acceptable fill material. 4. Firestone UltraPly TPO membrane is installed as continuous roofing or waterproofing layer on the roof. Rolls are overlapped (side laps and end laps) prior to the heat welding of the seam areas. 5. Install the UltraPly TPO Roofing System in accordance with current Firestone UltraPly TPO specifications, details and workmanship requirements. Storage: • Store away from sources of punctures and physical damage. • Assure that structural decking will support the loads incurred by material when stored on rooftop. The deck load limitations should be specified by the project designer. • Store away from ignition sources as membrane will burn when exposed to open flame. Precautions: 1. Refer to Material Safety Data Sheets (MSDS)for safety information. 2. Exercise caution when lifting, moving, transporting, storing or handling membrane rolls to avoid sources of punctures and possible physical damage. 3. Contact your Technical Coordinator at 1-800-428-4511 for specific recommendations regarding chemical or waste product compatibility with Firestone UltraPly TPO Membrane. LEED® Information: Post Consumer Recycled Content: 0% <9> M I-MDEcoUNTY o Pre Consumer Recycled Content: 15% ON'teC L US Manufacturing Location: Wellford, SC APPROVED Tuscumbia, AL ICC-ES ESR-2831 CCMC 13348-R Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-012 TIS#201 1/8/2013 Page 1 of 3 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS UltraPlyTm TPO Membrane Product Sizes Membrane Thickness:0.045"(1.14 mm) Membrane Thickness: .060" 1.52 mm) Membrane Weight: 0.23 Ib/ft2(1.1 kg/m2) Membrane Weight: 0.31 Ib/ft (1.5 kg/mZ) Available Sizes Available Colors Available Sizes Available Colors 5'x 100' (1.5 x 30.5 m) White,Tan, Gray 5'x 100' (1.5 x 30.5 m) White,Tan, Gray 5'x 200' (1.5 x 61 m) White 5'x 200' (1.5 x 61 m) White 6'2"x 100' (1.9 x 30.5 m) White,Tan, Gray 6'2"x 100' (1.9 x 30.5 m) White,Tan, Gray 8'x 100' (2.4 x 30.5 m) White,Tan, Gray 8'x 100' (2.4 x 30.5 m) White,Tan, Gray 8'x 200' (2.4 x 61 m) White 8'x 200' (2.4 x 61 m) White 10'x 100' (3.0 x 30.5 m) White,Tan, Gray 10'x 100' (3.0 x 30.5 m) White,Tan, Gray 10'x 200' (3.0 x 61 m) White 10'x 200' (3.0 x 61 m) White 12'4"x 100' (3.8 x 30.5 m) White,Tan, Gray 12'4"x 100' (3.8 x 30.5 m) White,Tan, Gray 12'4"x 200' (3.8 x 61 m) White 12'4"x 200' (3.8 x 61 m) White Physical Properties • - • 6878 Specification.) Property ASTM Standard Performance Typical Performance Typical Performance Minimum 45 mil 1 60 mil Overall Thickness: D 751 0.039"(1 mm) 0.045"(1.14 mm)±10% 0.060"(1.52 mm)±10% Coating over Scrim: D 7635 0.015"(0.38 mm) 0.017"(0.43 mm) 0.021"(0.53 mm) Breaking Strength: D 751, Grab 220 Ibf(979 N) 340 Ibf(1,512 N) 390 Ibf(1,735 N) Method Elongation of D 751, Grab 15% 25% 25% Reinforcement Break: Method Tearing Strength: D 751 55 Ibf(245 N) 120 Ibf(534 N) 120 Ibf(534 N) Brittleness Point: D 2137 -40°F(-40°C) Pass Pass Ozone Resistance, No D 1149 Pass(No Cracks) Pass Pass Cracks: Properties After Heat Aging (Retained Values)(ASTM D 573 670 h at 240°F(116°C)): Breaking Strength: D 751, Grab 90% Minimum >90% >90% Method Elongation at Break: D 751, Grab 90% Minimum >90% >90% Method Tearing Strength: D 751 60% Minimum >60% >60% Weight of Change: ± 1%Maximum < 1% < 1% Linear Dimension Change: D 1204,6 h at ±1%Maximum < 1% < 1% 158 F 70 C Water Absorption: D 471 ±3% Maximum <3% <3% PropertiesPhysical • - • Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-012 TIS#201 1/8/2013 Page 2 of 3 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS UltraPlyTm TPO Membrane P-10 pical Performance Minimum 45 mil Membrane mil Membran Pro a ASTM Standard Performance Typical Performance e Weather Resistance, 80°C Black Panel, no cracking,crazing when G 155 10,800 kJ/m2 >20,160 kJ/m2 >20,160 kJ/m2 wrapped around a 3" Minimum mandrel and inspected at 7X magnification: Puncture Resistance: FTM 101C, Method 265(1,180) 300(1,300) 2031 Dynamic Puncture D 5635 Pass(20 J) Pass(40 J) Resistance MD: Dynamic Puncture D 5635 Pass(35 J) Pass(50 J) Resistance CD: Static Puncture D 5602 Pass(25 kg) Pass(25 kg) Resistance: Radiative Properties Cool Roof Rating Council(CRRC): Initial 13 yr White Tan Gray Solar Reflectance 0.79/0.68 0.61 /0.55 0.34/Pending Thermal Emittance 0.85/0.83 0.81 /0.84 0.89/Pending Solar Reflectance Index(SRI) 98/81 71 /63 37/Pending Rated Product ID 0008 Licensed Manufacturer ID 0608 Classification Production Line ENERGY STAR& Initial/3 yr White Tan Solar Reflectance 0.79/0.78' 0.60/0.54 Thermal Emittance 0.85 0.81 *White membrane sample cleaned prior to age tes. LEED® White Tan Gray Solar Reflectance—ASTM E 903 0.81 0.63 0.37 Thermal Emittance—ASTM E 408 0.95 0.95 0.95 Solar Reflectance Index(SRI)—ASTM E 1980 102 77 43 'pireston¢ ENERGY STAR is only CR C � uK� �i valid in the United States ansc m>rn. MEMBERCHARTER oy� Please contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information. '1""'•°"E`s�� This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question.No Firestone representative is authorized to vary this disclaimer. Firestone Building Products i Sales:(800)4284442 i Technical(800)428-4511 i www.firestonebpco.com S723-RFS-012 TIS#201 I 1/8/2013 Page 3 of 3 Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS Heavy Duty Fastener Red Fasteners White Fasteners* 1 1/4" W56RAC4230 1 1/4" W56RAC4390 2" W56RAC4232 2" W56RAC4391 3" W56RAC4234 3" W56RAC4392 4" W56RAC4236 4" W56RAC4393 5" W56RAC4237 5" W56RAC4394 6" W56RAC4249 6" W56RAC4395 7" W56RAC4239 8" W56RAC4240 10" W56RAC4241 12" W56RAC4242 14" W56RAC4243 Product Inf• • Description: The Firestone Heavy Duty Fastener is specifically designed to be used in roofing applications which require additional corrosion protection and additional pullout resistance. The Heavy Duty Fastener may be used for attachment of roofing insulation and base sheets in combination with Firestone Insulation Plates, or for attachment of Firestone Batten Strips, Seam Plates, Termination Bars, and other accessories to steel, wood, concrete and other decks where approved by Firestone Technical Specifications. *NOTE: Firestone is not responsible for, nor guarantees that the white coating will remain on the fastener during or after installation. Because the coating on Firestone white fasteners is removed to some degree during the installation process, Firestone suggests that 1)the building owner be made aware of the expectations of the white fasteners and that repainting of the deck may be required after roofing is complete or 2)any deck painting take place after the roof is installed. In this case, any color of screw will work. Product Packaging Screw Length Thread Length Pieces per Plastic Pail Pails per Pallet 1 1/4" (31.8 mm) Full 1,000 40 2" (50.8 mm) Full 1,000 40 3" (76.2 mm) Full 1,000 60 4" (101.6 mm) 3" (76.2 mm) 1,000 60 5" (127.0 mm) 4" (101.6 mm) 1,000 40 6" (152.4 mm) 4" (101.6 mm) 500 60 T (177.8 mm) 4" (101.6 mm) 500 60 8" (203.2 mm) 4" (101.6 mm) 500 60 10" (254.0 mm) 4" (101.6 mm) 500* 24 12" (304.8 mm) 4" (101.6 mm) 500* 24 14" (355.6 mm) 4" (101.6 mm) 500* 24 *Packaged in cardboard boxes due to fastener length. May require lead time of thirty(30)days Firestone Building Products I Sales:(800)428- 442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-077 TIS#1002 1/11/2013 Page 1 of 2 Virestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS Heavy Duty Fastener Method of Application: 1. Using the#3 Phillips tip provided, and a variable speed drill, engage the fastener into the deck as noted below. Take care not to over or under drive the fastener. Threads must engage the decking material per Firestone Technical Specifications. 2. Determine screw length as follows: a. Steel Decks: Select fastener length to penetrate through the deck a minimum of 3/4"(19.1 mm). b. Wood Decks: Select fastener length to penetrate into or through the deck a minimum of 1" (25.4 mm). c. Concrete Decks: Select fastener length to penetrate into deck a minimum of 1" (25.4 mm). 3. If pre-drilling of the deck substrate is necessary, use a hammer drill in impact mode with a 7/32" (5.6 mm)carbide drill bit. Install fasteners by using a variable speed drill at a maximum of 1,500 rpm. Storage: Store in original, unopened packaging protected from the weather. Precautions: Eye protection must be worn during the installation of the fasteners and any drilling operation. LEED® Information: Postconsumer Recycled Content: 25% FM Preconsumer Recycled Content: 0% Manufacturing Location: West Chicago, IL APPROU® Physical Properties Property Typical Performance Material: SAE 1022, Heat Treated Steel Thread Size: 0.275"(6.98 mm) Nominal Diameter Threads/Inch: 13 min. Thread Design: Buttress thread Fastener Tip: Drill point design Fastener Head: #3 Phillips drive Pullout in New 22 gauge(0.76 mm) Steel Deck: Grade C(Grade 33): 595 lb(270 kg)min. Grade E(Grade 80): 650 lb(295 kg)min. Pullout in New Structural Concrete: 700 lb(317.5 kg)min. Pullout in New 3/4"(19.0 mm)Plywood 360 lb(163 kg)min. Deck: Corrosion Resistant Coating: Electrocoating of Firestone's Red and White fasteners both exhibit15%or less red rust after 30 cycles of Kesternich and exceed requirements of FM 4470. Please contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question.No Firestone representative is authorized to vary this disclaimer. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpeo.com S723-RFS-077 TIS#1002 1/11/2013 Page 2 of 2 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS Heavy Duty Seam Plate Item Description Item Number Pail: 1,000 Pieces W56TPOPL03 Product • • Description: Firestone Heavy Duty Seam Plates are specifically designed to be used for the attachment of Firestone UltraPlyTm TPO Membranes to approved substrates. Firestone Heavy Duty Seam Plates are to be used with Firestone Heavy Duty or All- Purpose Fasteners into 22 gauge steel, wood or structural concrete decks (Heavy Duty Fasteners only). They may also be used with Firestone Purlin Fasteners to attach membrane to structural steel purlins. The plates are packaged in a clear plastic sleeve for easy handling. The sleeve has an easy-open pull tab with serrations that runs the length of the sleeve. Product Packaging Pail: 18 sleeves per pail (1,000 pieces) Pail Weight: 48 lb(21.8 kg) Pallet: 40 pails Methods of Application: With Screw Gun: 1. Heavy Duty Seam Plates may be installed with a conventional screw gun. Plates are positioned within the seam area with"Firestone" logo facing up and the EyehooksTm against the membrane. 2. The stacked plates allow for the installer to carry fifty-six (56) plates at one time, which are all oriented in the same direction, making it easier to lay out the plates. 3. Once placed in the correct seam location, the plate is attached with Firestone All-Purpose, Heavy Duty, or Purlin Fasteners as appropriate. With AccuSeamTm Tool: AccuSeam Tools can be purchased from ITW Buildex. The AccuSeam "boot' attachment can be purchased by owners of AccuTrac®III tools upon request. Tools with serial number of 12134 or higher are required. Training on the AccuTrac Tool is recommended prior to use. 1. Remove the weight from the plate magazine by lifting out. Remove one tube of stacked plates from the pail, and tear off the perforated edge. This will expose the stack of plates, which are all oriented in the same direction. 2. Remove and slide the plates into the magazine with the"Firestone" logo facing up, eyehooks facing down. 3. Replace the weight, and you are ready to start. 4. Drop a fastener into the feed tube,turn the screw gun on, and push the tool all the way down until the fastener is properly seated in the plate. 5. Pull the screw gun back up, move the tool to the next position, drop in your fastener, and repeat step 4. Firestone Building Products I Sales:(800)42844421 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-101 TIS#1108 09/19/2012 Page 1 of 2 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS Heavy Duty Seam Plate Storage: Store in original, unopened containers, protected from the weather. LEED® Information: Post Consumer Recycled Content: 0% F M Post Industrial Recycled Content: 21% Manufacturing Location: West Chicago, IL APPROVED Physical Properties Typical Performance Material: Galvalume®Sheet Steel AZ50 or AZ55 Material Thickness: 0.037"(0.94 mm) Size: 2 3/8"(60.3 mm)maximum diameter Hole Diameter: 0.265"±0.003"(6.73 mm±0.076 mm) Pull Through Resistance: 700 lb(317.5 kg)from center hole Corrosion Resistance: Meets FM Requirement—Less than 15%red rust in 15 cycles of Kesternich Testing (DIN 50018) Galvalume®is a registered trademark of BIEC International, Inc. EyehookTM,AccuSeamTM, and AccuTrac®III are trademarks of OMG. Please contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question.No Firestone representative is authorized to vary this disclaimer. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpeo.com S723-RFS-101 TIS#1108 09/19/2012 Page 2 of 2 Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS UltraPlyTm Bonding Adhesive s Item Description Item Number � Bonding Adhesive W56TP03005 'Firestone. Ultra Ply' 9onaing Adhesive_ !vSt PO.3005 -,z T,-w . .ro.:ooe Product • • " Description: Firestone UltraPly Bonding Adhesive is a solvent based contact adhesive designed specifically for bonding Firestone UltraPly TPO membranes to approved insulations in addition to wood, metal, masonry and other acceptable substrates. Note: Not for use in adhering UltraPly TPO XR membranes. Method of Application: 1. Surfaces to receive Firestone UltraPly Bonding Adhesive must be clean, smooth, dry, and free of sharp edges, loose and foreign materials, oil, grease, and other contaminants. 2. Stir the adhesive thoroughly to achieve a uniform mix with no sediment on the bottom and no marbling evident before and during use. 3. Apply UltraPly Bonding Adhesive at about the same time to both the exposed underside of the sheet and the substrate to which it will be adhered so as to allow approximately the same drying time. Apply UltraPly Bonding Adhesive evenly avoiding areas of accumulation. 4. Apply the UltraPly Bonding Adhesive with a solvent resistant paint roller, and roll the adhesive onto the mating surfaces. When applying UltraPly Bonding Adhesive, ensure complete uniform coverage of both surfaces that will be adhered. Care must be taken not to apply Bonding Adhesive over seam areas. 5. UltraPly Bonding Adhesive can be dispensed by means of power rollers or industrial spray equipment. Other equipment may be used as recommended by the manufacturer for application of this adhesive. Note: Spray applied bonding adhesive requires back- rolling with 9"(228.6 mm)wide solvent resistant roller(medium nap)to insure 100% coverage of the adhesive on the substrate and membrane. 6. Allow Bonding Adhesive to flash off until tacky. Touch down on the Bonding Adhesive surface with a clean, dry finger to be certain that the adhesive does not string. As you are touching the adhesive, pushing straight down to check for stringing, also push forward on the adhesive at an angle to ensure that the adhesive solvents have flashed off and are ready throughout its thickness. If either motion exposes wet areas or sticking when the finger is lifted, then it is not ready for mating. Flash off time will vary depending on ambient conditions. 7. Starting at the fold, roll the previously coated portion of the sheet into the coated substrate slowly and evenly so as to minimize wrinkles. 8. To ensure proper contact, compress the bonded half of the sheet to the substrate with a stiff push broom using heavy pressure immediately after mating. 9. Contact your Firestone Technical Coordinator at 1-800-428-4511 for specific application information. Storage: • Store in original unopened containers at temperatures between 60 OF - 80 OF (16 °C-27 °C) until ready for use. • For optimum results, rotate your stock to ensure stored material has not exceeded the shelf life of one year. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-059 TIS#808 12/10/2013 Page 1 of 3 Twestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS UltraPlyTm Bonding Adhesive Shelf Life: Shelf life of one year can be expected if stored in original sealed container at temperatures between 60 OF-80 OF (16 °C- 27°C). If exposed to lower temperatures, restore to room temperature prior to use. Shelf life will be shortened if exposed to elevated temperatures for a prolonged period of time. Coverage: A coverage rate of 45 - 60 ft2 per gallon (1.10 — 1.47 mz per liter) may be obtained depending on the substrate. Some insulation surfaces are more uneven and porous and will result in a lower coverage rate while smooth non-porous substrates will result in higher coverage rates. Rates are based on roller application to both mating surfaces. Very porous substrates (rough wood, concrete block) may require two coats of Bonding Adhesive, to ensure proper adhesion. This can be determined by testing a small area. Check by adhering a small piece of membrane to the porous substrate to verify the bonding strength. Precautions: 1. Review applicable Material Safety Data Sheet prior to using. 2. Flammable. Keep away from fire and open flame and other possible ignition sources during storage and use. Do not smoke when using. 3. Harmful or fatal if swallowed. 4. Avoid prolonged inhalation. 5. Avoid prolonged contact with skin. Gloves should be worn (OSHA approved). 6. Avoid eye contact by wearing safety goggles with side shields. 7. Thinning is not allowed. 8. Do not use for splicing. 9. Do not use with EPDM or XR membranes. 10. Use only in well ventilated areas. 11. Cover tightly when not in use. 12. Recommended cleaner is Toluene (while fluid). Typical • • - Minimum Performance Base: A blend of Polychloroprene and SBR rubbers Color: Yellow Solvents: A blend of Acetone, Hexane, Toluene and Xylene Viscosity: 3,300-3,800 cps, with R.V.F. spindle @ 10 rpm Weight/Gallon: 6.6-7.4lb/gal Specific Gravity: 0.7909-0.8868 V.O.C. Content: 5.282 lb/gal (633 g/L) Firestone Building Products I Sales:(800)428.4"2 I Technical(800)428-4511 I www.firestonebpco.com S723-RFS-059 TIS#808 12/10/2013 Page 2 of 3 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS UltraPlyTm Bonding Adhesive LEED® Information: ��psSlFiFo Post Consumer Recycled Content: 0% FM CMM1DADEC=0UNTY Post Industrial Recycled Content: 0% Q Q us Manufacturing Location: South Bend, IN APPROVED Packaging: • Available in 5 gallon (18.9 L) pail • Each pail weighs about 41 lb (18.6 kg) Y" Approved Power Equipment: - Garlock 25ST Roller Boss Power Roller 4 hp Honda Engine, 4 CFM Compressor, 25 gal pressurized supply tank (20 gal for material; 60-80 psi), Up to 100 psi rating, 2—%"x 30'supply hoses with swivels, 2— 18" roller head assemblies _ --� Garlock 2120 Commander Spraver 18 hp Kohler Engine, 4500 psi Rating, 5 Gallon per Minute Flow, 1200 psi Pressure(minimum), Pump Displacement 45:1, GPM Rating: up to 5 gpm, 1/"x 100' hose, 2" Intake pipe with screen, 5 or 55 gal drum containers, Graco Spray Tips: .023 to .031 diameter hose Garlock Twin Gun Airless Sprayer 6.5 hp Honda Engine, 3000 psi Rating, Pump Displacement 30:1, GPM Rating: up to 1 gpm, Up to 400' of single %'diameter hose, Up to 200' of dual '/2'diameter hose, %" Intake pipe with screen, 5 or 55 gal drum containers, Bulk tank containers, Graco Spray Tips: .019 to .025 diameter hose(1850 psi operating pressure) Graco Spray Equipment: P70EC4-70—70:1 Xtreme Sprayer Package w/Heavy Duty car, Hopper package, w/NXT motor and Data Track,Xtreme-Duty high pressure hose, 3/8"x 50', 7250 psi, with x 6'whip hose, XTR-7 applicator with XHD821-825 tips Please contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question.No Firestone representative is authorized to vary this disclaimer. Firestone Building Products I Sales:(800)428.4442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-059 TIS#808 12/10/2013 Page 3 of 3 T restone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS ISO 95+TM GL Insulation a li Item Description Flat and Tapered Polyiso Boards Cellulosic Glass Reinforced Facer Flat Boards: 4'x 4' (1.22 m x 1.22 m) 4'x 8' (1.22 m x 2.44 m) Tapered Boards: 4'x 4' (1.22 m x 1.22 m) Slope range: 1/16" per foot(.5%)to 1/2" per foot(4%) r Thickness range: 0.5" (12.7 mm)to 4.0" (101.6 mm) Meets or exceeds performance requirements of ASTM C 1289,Type II, Class 1 Product Information Foam Core Description: Firestone ISO 95+ GL flat and tapered roof insulation consists of a closed-cell polyiso foam core laminated to a black glass reinforced mat facer on both major surfaces. Flat and tapered ISO 95+ GL insulation provides outstanding thermal performance on commercial roofing applications,while providing positive rooftop drainage to help eliminate ponding water when tapered ISO 95+ GL insulation is used. Method of Application: 1. Insulation shall be neatly fitted to all roof penetrations, projections and nailers. 2. No more insulation shall be installed than can be covered with membrane and completed before the end of each day's work or before the onset of inclement weather. 3. Firestone ISO 95+ GL board may be installed using: • Firestone fasteners and plates o NOTE: For ballasted systems,the top layer of Firestone insulation may not be mechanically attached. • Hot asphalt(requires a cover board) • Firestone approved insulation adhesives o I.S.O. Twin PackTM o I.S.O. StickTM o I.S.O. SprayTM R o I.S.O. FIXTM II Acceptable Immediate Substrates: • 3,000 psi Structural concrete (must be clean, dry, and properly cured) • Steel deck(min 22 ga) • Plywood and OSB (min '/z') • Lightweight concrete • Gypsum deck(min 2") NOTE: Please consult the Design Guides and QuickSpecs online at www.firestonebpco.com to review specific information regarding the assembly. Storage: • Keep insulation dry at all times • Elevate insulation above the deck or ground • Cover insulation with waterproof tarps Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com TIS#901 12/09/2015 Page 1 of 3 Twestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS ISO 95+TM GL Insulation Precautions: • Polyiso foam will burn if exposed to a flame of sufficient heat and intensity. Keep away from heat, sparks, and open flames. • Protect against dust that may be generated during installation. • Refer to Safety Data Sheet(SDS)for additional information. • Take care when transporting and handling Firestone insulation to avoid physical damage. Specification Compliance: y PI ASTM C1289, Type II, Class 1 'tyMark' UL Classified—UL1256 APWHI CVUS rnBce,r;sea�rr�-,�ro FM Class 1 Approved Manufactured in an ISO 9001 Registered Facility CAN/ULC-S704, Type 1, Class 3 MAMMADECOUNTY CCMC 13274-L LEED® Information: See Recycled Content in table below. Manufacturing Locations: Florence, KY Corsicana, TX Bristol, Ct De Forest, WI Salt Lake City, UT Youngwood, PA Jacksonville, FL NOTE: Miami Dade Classified polyiso is only produced in the Jacksonville, FL and Youngwood, PA facilities. Typical • • - : ' T 11, Class 1) ype Pro a ASTM Test Method Firestone Typical Performance Compressive Strength: D1621 20 psi (138 kPa) Density: D1622 2 pcf(32 kg/m ) Dimensional Stability: D2126 <2% Moisture Vapor Transmission: E96 <1 perm (<57.5 ng/(Pa•s•mz)) Water Absorption: C209 <1% by volume Service Temperature: ---- -100 to 250 °F (-73 to 121°C) Flame Spread: E84 Index 50 Smoke Development: E84 Index 160- 180 `25 psi(172 kPa)available upon request. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com TIS#901 12/09/2015 Page 2 of 3 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS ISO 95+TM GL Insulation Product • • Thickness* (R-Value) Max Flute Span Approx. Recycled Content inches mm ** inches mm Post Consumer Post Industrial Total 1.0 25.40 5.7 2.62 66.67 37% 15% 52% 1.1 27.94 6.3 2.62 66.67 36% 15% 51% 1.2 30.48 6.8 2.62 66.67 34% 15% 49% 1.3 33.02 7.4 3.67 93.34 1 32% 15% 47% 1.4 35.56 8.0 3.67 93.34 30% 15% 45% 1.5 38.10 8.6 4.37 111.12 29% 15% 44% 1.6 40.64 9.1 4.37 111.12 27% 15% 42% 1.7 43.18 9.7 4.37 111.12 26% 15% 41% 1.75 44.45 10.0 4.37 111.12 26% 15% 41% 1.8 45.72 10.3 4.37 111.12 25% 15% 40% 1.9 48.26 10.8 4.37 111.12 24% 15% 39% 2.0 50.80 11.4 4.37 111.12 24% 15% 39% 2.1 53.34 12.0 4.37 111.12 22% 15% 37% 2.2 55.88 12.6 4.37 111.12 21% 15% 36% 2.25 57.15 12.9 4.37 111.12 21% 15% 36% 2.3 58.42 13.2 4.37 111.12 21% 15% 36% 2.4 60.96 13.8 4.37 111.12 20% 15% 35% 2.5 63.50 14.4 4.37 111.12 20% 15% 35% 2.6 66.04 15.0 4.37 111.12 19% 15% 34% 2.7 68.58 15.6 4.37 111.12 18% 15% 33% 2.75 69.85 15.9 4.37 111.12 18% 15% 33% 2.8 71.12 16.2 4.37 111.12 18% 15% 33% 2.9 73.66 16.8 4.37 111.12 17% 15% 32% 3.0 76.20 17.4 4.37 111.12 17% 15% 32% 3.1 78.74 18.0 4.37 111.12 16% 15% 31% 3.2 81.28 18.6 4.37 111.12 16% 15% 31% 3.25 82.55 18.9 4.37 111.12 16% 15% 31% 3.3 83.82 19.2 4.37 111.12 16% 15% 31% 3.4 86.36 19.9 4.37 111.12 15% 15% 30% 3.5 88.90 20.5 4.37 111.12 15% 15% 30% 3.6 91.44 21.1 4.37 111.12 14% 15% 29% 3.7 93.98 21.7 4.37 111.12 14% 15% 29% 3.75 95.25 22.0 4.37 111.12 14% 15% 29% 3.8 96.52 22.3 4.37 111.12 14% 15% 29% 3.9 99.06 23.0 4.37 111.12 14% 15% 29% 4.0 101.60 23.6 4.50 114.30 14% 15% 29% *Other thicknesses available upon request. **R-values provide a 15-year time-weighted average in accordance with CAN/ULC-S770. Please contact Quality Building Services Technical Department at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice.Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications or other technical documents, subject to normal roof manufacturing tolerances. Neither Firestone nor its representatives practice architecture.Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure.Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question.No Firestone representative is authorized to vary this disclaimer. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com TIS#901 12/09/2015 Page 3 of 3 Virestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS All-Purpose Fastener Red Fasteners White Fasteners* 1 1/4" W56RAC4200 1 1/4" W56RAC4199 1 5/8" W56RAC4201 21/4" W56RAC4215 2 1/4" W56RAC4202 2 7/8" W56RAC4216 2 7/8" W56RAC4203 3 1/4" W56RAC4217 3 1/4" W56RAC4204 3 3/4" W56RAC4218 3 3/4" W56RAC4205 4 1/2" W56RAC4219 41/2" W56RAC4206 5" W56RAC4220 5" W56RAC4207 6" W56RAC4221 7" W56RAC4222 7" W56RAC4209 8" W56RAC4223 8" W56RAC4210 10000'r Product • • Description: Firestone All-Purpose Fasteners are used in roofing applications for the attachment of roofing insulation and base sheets in combination with Firestone Insulation Plates and attachment of Firestone Batten Strips, Seam Plates, Termination Bars, and other accessories to steel and wood substrates where approved by Firestone Technical Specifications. The Firestone All-Purpose Fastener is Factory Mutual (FM)approved. *NOTE: Firestone is not responsible for, nor guarantees that the white coating will remain on the fastener during or after installation. Because the coating on Firestone white fasteners is removed to some degree during the installation process, Firestone suggests that 1)the building owner be made aware of the expectations of the white fasteners and that repainting of the deck may be required after roofing is complete or 2) any deck painting take place after the roof is installed. In this case, any color of screw will work. Product Packaging Screw Length Thread Length Pieces per Plastic Pail Pails per Pallet 1 1/4" (31.75 mm) Full 1,000 60 1 5/8" (41.28 mm) Full 1,000 60 2 1/4" (57.15 mm) Full 1,000 60 2 7/8" (73.03 mm) Full 1,000 60 3 1/4" (82.55 mm) 3" (76.2 mm) 1,000 60 3 3/4" (95.25 mm) 3" (76.2 mm) 1,000 60 4 1/2" (114.3 mm) 3" (76.2 mm) 1,000 60 5" (127.0 mm) 4" (101.6 mm) 1,000 60 6" (152.4 mm) 4" (101.6 mm) 1,000 60 7" (177.8 mm) 4" (101.6 mm) 500 60 8" (203.2 mm) 4" (101.6 mm) 1 500 1 60 Method of Application: 1. Using the#3 Phillips tip provided, and a variable speed drill, engage the fastener into the deck as noted below. Take care not to over or under drive the fastener. Threads must engage the decking material per Firestone Technical Specifications. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-076 TIS#1001 1/11/2013 Page 1 of 2 Twestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS All-Purpose Fastener 2. Determine screw length as follows: a. Steel Decks: Select fastener length to penetrate through the deck a minimum of 3/4"(19.1 mm). b. Wood Decks: Select fastener length to penetrate into or through the deck a minimum of 1"(25.4 mm). 3. All-Purpose fasteners may not work as expected through existing roof systems or unusual substrates. Consideration should be given to using Firestone HD fasteners in these instances. Storage: Store in original, unopened packaging protected from the weather. Precautions: Eye protection must be worn during the installation of the fasteners. LEED® Information: Postconsumer Recycled Content: 15% FM Preconsumer Recycled Content: 10% Manufacturing Location: Bryan, OH APPROVED PropertiesPhysical PMRegy Typical Performance Material: SAE 1022, Heat Treated Steel Thread Size: 0.235"(6.5 mm) Threads/Inch: 13 Thread Design: Symmetrical Fastener Tip: Drill point Fastener Head: #3 Phillips drive Pullout in New 22 gauge(0.76 mm) Steel Deck: Grade C(Grade 33): 360 lb(163.3 kg Grade E(Grade 80): 400 lb(191.4 kg) Pullout in New 3/4"(19.0 mm)Plywood 400 lb(191.4 kg) Deck: Corrosion Resistant Coating: Electrocoating of Firestone's Red and White fasteners both exhibit 15%or less red rust after 30 cycles of Kesternich and exceed requirements of FM 4470. Please contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for fumishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question.No Firestone representative is authorized to vary this disclaimer. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-076 TIS#1001 1/11/2013 Page 2 of 2 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS Insulation Fastening Plate Item Description Item Number f Pail: 1,000 Pieces W56RAC4190 d Product Information Description: Firestone Insulation Fastening Plates are specially designed to be used with Firestone All-Purpose, Heavy-Duty, Concrete Drive and Stainless Steel Fasteners in roofing applications for attaching insulation as required by Firestone Specifications. '-Product Pac • • Plate Diameter Weight Pieces per Plastic Pail Pails per Pallet 3"(76 mm) 42 lb(19 kg)per pail 1,000 60 Method of Application: Position insulation plates over insulation as specified by Firestone Specifications. Attach plates to roof deck using the appropriate Firestone fastener. Install plates ribbed side up with the"Firestone" identification visible. Storage: Store in unopened original containers protected from the weather. Precautions: 1. Do not overdrive or underdrive fastener. 2. Plates are designed to anchor roof insulation only. 3. Avoid field seams directly over insulation plates. 4. Cannot be used with Firestone Heavy Duty(HD) Plus Fasteners. LEED® Information: Postconsumer Recycled Content: 8% FM Preconsumer Recycled Content: 17% Manufacturing Location: Cleveland, OH APPROVED Physical Properties PMgerty Typical Performance Material: AZ50 Galvalume® Material Thickness: 0.017"(0.43 mm)-0.023"(0.58mm) Diameter: 3"(76 mm) Corrosion Resistant Coating: Meets FM No.4470 Criteria Pull Through Resistance: 400 Ibf(181.4 kgf)from center hole GalvalumeO is a registered trademark of BIEC International,Inc. Please contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture.Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question.No Firestone representative is authorized to vary this disclaimer. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com S723-RFS-099 TIS#1106 1/30/2013 Page 1 of 1 'Firestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS Insulation Attachment Patterns Item Description Fastening Patterns Product Inf• • Description: The diagrams below show the required patterns for proper placement of approved fasteners and plates for insulation on Standard Firestone 55 mph Roofing Systems. The most common fastener density and pattern requirements are shown on this technical information sheet. Certain specifications may call for increased densities of fasteners in the perimeters and corners of roofs. For non-standard fastener densities, contact The Quality Building Services Technical Department at 800-428-4511 or visit the Firestone Website at www.firestonebpco.com. NumberMinimum of • Plates Property Insulation Thickness 4'x4'Boards 4'x8'Boards Mechanically Fastened Any approved insulation Any approved 4 5 Systems*: thickness ISO 95+T"^ GL Insulation, RESISTATM 0.5"-1.4" 8 16 Insulation, HailGardTm Composite Board, 1.5"-1.9" 6 12 ISO 95+GL Woodfiber Composite, or ISOGARDTm HD Composite 2"-4" 4 8 FiberTopTM Insulation 0.5"A 8 16 Structodeck HD(with primed red coating) ISOGARD HD Cover Board 0.5"A" 6 12 0.25" 8 10 SECUROCK®Gypsum Fiber Roof Board (in a single-ply system) 0.50" 6 8 0.625" 4 8 Non-Mechanically Fastened 0.25" 8 16 Systems: DensDeck®(in a single-ply system) 0.50" 6 12 0.625" 4 8 0.25" 6 12 DensDeck Prime(in a single-ply system) 0.50" 5 10 0.625" 4 8 DensDeck or SECUROCK Gypsum Fiber Any approved 6 12 Roof Board (in an asphalt system) thickness DensDeck Prime(in an asphalt system) Any approved 4 8 thickness (All the above insulations require the minimum fastener densities listed) *Contact the Quality Building Services Technical Department for fastening rates with and air or vapor barrier/retarder. Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-4511 1 www.firestonebpco.com TIS#950 08/16/2016 Page 1 of 3 Vitrestone TECHNICAL INFORMATION SHEET BUILDING PRODUCTS Insulation Attachment Patterns Fastening Patterns: Representing 4'x8' insulation boards Please refer to the above mentioned attachment patterns for a specific board attachment rate. For further information relating to attachment patterns or system specifications please refer to the Firestone Technical Database at www.firestonebpco.com. -21" A T' 24" 0- 0 97, E) 0 0 (D 0 0 0 0 0 0 5FASTENERS 6 FASTENERS 8 FASTENERS 9FASTENERS -24 -24 61 18" 6'-, -1 (D 1 1 12 12, V, W 2W -17, 21711�21 TT - 0 0— (D 0-7, GU. 6. 6. W, 96, 0 0 O 0 (D 0 O O 0 O 0 0 0 0 0 0 0 0 O 0 (D (D 0 12 FASTENERS 14 FASTENERS 16 FASTENERS 18 FASTENERS Firestone Building Products I Sales:(800)428-4442 1 Technical(800)428-45111 www.firestonebpeo.com TIS#960 08/16/2016 Page 2 of 3 MATERIAL: SNAP COPING 22 GA.GALV.STEEL V 24 GA.GALV.STEEL .032"ALUMINUM .040"ALUMINUM COPING CAP .050"ALUMINUM .063"ALUMINUM OTHER COLOR SELECTION: STONE WHITE SR _BONE WHITE SR 1 1/4" ALMOND SR y SANDSTONE SR FASTENER SLATE GRAY SR CITYSCAPE SR CHARCOAL GRAY SR _SIERRA TAN SR _MEDIUM BRONZE SR DARK BRONZE SR _MATTE BLACK SR BRANDYWINE SR 8"WIDE BACKUP PLATE COLONIAL RED SR Y TERRA COTTA SR MANSFORD BROWN SR REGAL RED SR CLEAT SPACED AWARD BLUE SR SKY BLUE SR 12" 22 L GALV. -ELECTRIC BLUE SR REGAL BLUE SR 5'O.C. -TEAL SR PATINA GREEN SR DARK IVY SR _SHERWOOD GREEN SR HARTFORD GREEN SR HEMLOCK GREEN SR TROPICAL PATINA SR *= Premium Color SR=Solar Reflectant Color CERTAIN MATERIALS NOT AVAILABLE IN ALL COLORS PROJECT INFORMAAATION:,���,,,��,�� APPROVAL: NOTES: PROJECT NAME: _ '' '`lull�� SIGNATURE: 1) SEALANT AT JOINT PROVIDED MANWACTURE: DATE: 2)SIZES TO BE FIELD VERIFIED SHEET METAL INSTALLED BY: SHEET METAL PROVIDED BY: 3)METAL IS INCLUDED IN FIRESTONE RED SHIELD ROOFING SYSTEM WARRANTY • r 6 CONT"n CTiNG CO MP/IµY. INC. AFIREtil'UNEGF-HiltItU(:UNIKAL;IUK BUILDING PRODUCTS COMPANY MATERIAL: TPO COATED METAL TPO COATED METAL 11/4P PJNG COLOR SELECTION: SFIANK NAIL 4!' O.C. WHITE ONLY 11/4" RING SHANK NML 1210 O.C. 22 GA CENT. CLEAT SIZED PER PLANS PROJECT INFORMATION: APPROVAL: NOTES: PROJECT NAME: SIGNATURE: 1) SEALANT AT JOINT PROVIDED MANUFACTURER: DATE: 2)SIZES TO BE FIELD VERIFIED SHEET METAL INSTALLED BY: SHEET METAL PROVIDED BY: 3)METAL IS INCLUDED IN .il .. Apirestone ROOFING SYSTEM WARRANTY A FIRESTONE CERTIFIED CONTRACTOR BUILDING PRODUCTS COMPANY 21 MATEIRJAL: GUTTER 22 GA.GALV.STEEL 24 GA.GALV.STEEL .032"ALUMINUM .040"ALUMINUM .050"ALUMINUM .063"ALUMINUM OTHER COLOR SELECTION: STONE WHITE SR BONE WHITE SR ALMOND SR SANDSTONE Sit SLATE GRAY SR CITYSCAPE SR CHARCOAL GRAY SR SIERRA TAN Sit MEDIUM BRONZE SR DARK BRONZE SR MATTE BLACK SR 13RANDYWINE SR COLONIAL RED SR TERRA COTTA SR MANSrORD BROWN SR REGAL RED SR AWARD BLUE SR, SKY BLUE SR ELECTRIC BLUE SR REGAL BLUE SR TEAL SR PATINA GREEN SR DARK IVY SR SHERWOOD GREEN SR HARTFORD GREEN SR HEMLOCK GREEN SR rROPICAL PATINA SR SHNONRIAN91a"'14014"br.@0414N4- Premium Color SR=Solar Reflectant Color CERTAIN MATERIALS NOT AVAILABLE IN ALL COLORS PROJECT INFORMATION: APPROVAL: NOTES: PROJECT NAME: 11N SIGNATURE: 1) SEALANT AT JOINT PROVIDED MANUFACTURER: DATE: 2)SIZES TO BE FIELD VERIFIED SHEET METAL INSTALLED BY: SHEET METAL PROVIDED BY: 3)GUTTER IS INCLUDED IN FIRESTONE RED SHIELD ROOFING SYSTEM WARRANTY 0vtAff jw Aw-3w r C90L 430 T 0 n A FIRESTONE CERTIFIED CONTRACTOR BUILDING PRODUCTS COMPANY MATERIAL: DOWNSPOUT 22 GA.GALV.STEEL 24 GA.GALV.STEEL .032"ALUMINUM .040"ALUMINUM .050"ALUMINUM .063"ALUMINUM OTHER COLOR SELECTION: _STONE WHITE SR _BONE WHITE SR _ALMOND SR _SANDSTONE SR _SLATE GRAY SR _CITYSCAPE SR _CHARCOAL GRAY SR _SIERRA TAN SR _MEDIUM BRONZE SR _DARK BRONZE SR _MATTE BLACK SR _BRANDYWINE SR _COLONIAL RED SR _TERRA COTTA SR _MANSFORD BROWN SR _REGAL RED SR _AWARD BLUE SR _SKY BLUE SR _ELECTRIC BLUE SR _REGAL BLUE SR _TEAL SR _PATINA GREEN SR _DARK IVY SR _SHERWOOD GREEN SR SIZED PER PLANS T A N _HARTFORD GREEN SR _HEMLOCK GREEN SR 1 1\ 1 Lt�l�l 1J TROPICAL PATINA SR PER WR *= Premium Color SR= Solar Reflectant Color CERTAIN MATERIALS NOT AVAILABLE IN ALL COLORS PROJECT INFORMATION: APPROVAL: NOTES: PROJECT NAME: # II SIGNATURE: 1) SEALANT AT JOINT PROVIDED MANUFACTURER: DATE: 2)SIZES TO BE FIELD VERIFIED SHEET METAL INSTALLED BY: SHEET METAL PROVIDED BY: 3)METAL IS INCLUDED IN FIRESTONE RED SHIELD aTo ® 1pa re ste n e ROOFING SYSTEM WARRANTY i 4) STANDARD COLORS ONLY 6 CO NTA AC TINfi COMPANY, iNC A FIRESTONE CERTIFIED CONTRACTOR BUILDING PRODUCTS COMPANY ColorMetal Systems .. I I Stone White Bone White Almond Sandstone Slate Gray Cityscape Charcoal Gray Sierra Tan Medium Bronze Dark Bronze Extra Dark Bronze Matte Black Brandywine Colonial Red Terra Cotta Mansard Brown Regal Red Award Blue Sky Blue Electric Blue Regal Blue Teal Patina Green Dark Ivy Sherwood Green Hartford Green Hemlock Green Tropical Patina Firestone BUILDING PRODUCTS NOBODY COVERS YOU BETTER:" Colors shown are as close to actual painted steel as allowed by the printing process.Contact your local sales rep for actual metal samples. 11/5/2015 2 in.x 6 in.x 16 ft.Pressure-Treated Lumber-5103002020616000-The Home Depot More saving. Your Store:Thompson Lane#732 Momdoing: Use Current Location or find store Model#510300202o6i6000 ; Internet#202711426 1 Store SKU#496669 2 in. x 6 in. x 16 ft. Pressure-Treated Lumber Write the First Review I Questions&Answers(1) a. o Open Expanded View Click Image to Zoom PRODUCT OVERVIEW Model#510300202o6i6000 Internet#202711426 Store SKU#496669 Borate treated lumber provides warranted protection against rot and termites,including the formosan termite and rates low in environmental impact. Hot-dipped galvanized fasteners are recommended,as are connectors made with g90 galvanization([er astm a 653). California residents:see Proposition 65 informationx • Well suited for sill plates,trusses,wall plates,ceiling joists,floor beams,door frames and other interior applications • For areas that are above ground and not subject to direct contact with water • Meets american wood-preservers'association(awpa)standards • Resists damage from carpenter ants and carpenter beetles,and may provide control of cockroaches living in the immediate vicinity • Handles like ordinary untreated wood • Adds years of life to typical wood structures • Lifetime Limited Warranty SPECIFICATIONS DIMENSIONS Actual product thickness(in.) 1.5 Nominal productwidth(in.) 6 Actual productwidth(in.) 5.5 Product Depth(in.) 1.5 Nominal Product H x W(In.) 2x6 Product Height(in.) 192 http://www.homedepot.com/p/Unbranded-2-in-x-6-in-x-16-ft-Pressure-Treated-Lumber-5103002020616000/202711426 1/2 11/5/2015 2 in.x 6 in.x 16 ft.Pressure-Treated Lumber-5103002020616000-The Home Depot Nominal Product Height(in.) 2 Product Length(ft.) 16 ft Nominal Product Length(ft.) 16 Product Length(in.) 192 Nominal Product Length(in.) 192 Product Width(in.) 5.5 Nominal Width 6 in DETAILS Chemical retention(lb./cu,ft.) .17 Stainable/Paintable Stainable&Paintable Contact Type Allowed Above Ground Texture Smooth Fastener recommendation -Hot dipped galvanized Type of Pressure Treatment Other Pressure Treated Yes Water Resistant No WARRANTY/CERTIFICATIONS Manufacturer Warranty Lifetime limited warranty hftp:/Atvww.homedepot.com/p/Unbranded-2-in-x-6-in-x-16-ft-Pressure-Treated-Lumber-5103002020616000/202711426 212 •�St'Oh e ' IWARRANTY o . .. CPR .. :.�.::'':'.:: ��..� �': �::��.�.::�'.:'.:: ::,�:�; �::� �.�.:��:.::: ':�..�.�:•••':':�'••'.�: Ef?. ..t[ .E...D .Rflb.FI.N:�:SIB.S'T.EI! .-U0 *T€D�:W 4 k-P-'A Tlf :W..arFdnty.Nod; :.' .: :.":: :.:: . '. ,:; :.' :. :.':': :,::,FBPCC<.#.: : :': : : .:; :.` .S4udre'Poota9e,:.' .: :.':+.•::: s:f:::: :.' .: :.'.': .: `.: :;. ::3uildirig".0Wddr:::; SAMPLE "'.$ti�ldipg'Address;':•:':'.•: / alllarranty?eriod,Ofr Roof ti g:trOlitraet4re. '...:... Forrthe'warran. pe-ridd'indlc Qted:above•Firestone' ild'n'Pro u.:i.ty.p.. .a .Ba .i g , d.c;;eoinpdny,;lt�("Firestone"),:ap:Fndlacia limited liabiliKyCompany;.warrarits�'tolfte Biilitling'.:,:,':'; Owner:('Oinnar".)'nafMed'atiove ti!.Sl F'rOston'.Wiil;.subject'to.Yh'eTerrs7s;'Cdndiiioh's•and LirnjtatidnS'setf6rtM below,repai�'any leak.in'Yhe FireStone:Roofing ; System•.P'Sys?erti'')•�.�::: :.� :: :.':"::,:::. .•::.i'. :.:::;:;,.•,•.:.,'::. . �.:;:; :.��::•:.•:':�',:`•�.�. '.:•::�:.��:: :.•::';:'� :�:'::'•�.`.•�.�,�: :.��::•:.•:':•:.'� :::.:.TE{t►9S,:CONbITI(?NS•ANq.LJ[MITAONS. :..:.:'.: .:".'.:'.::''.• :. :.:•.''.:; :'. 1::'•,.•Prohutts-Cnveretl,'Tfie.Systexish all'mean;on(q.ttie'F.irestohe:brand.rQoficig'rtie'Fnbrane5,pKestone.bPand:rodfin in ul tipn :Firestoh braid: fin 4 s a s e roq .g : metal;:and:other'Fireetone.brand.roofing:acciassores•wherrinsial fed 4f -ieCcordance with ffrestggj jechhical-specification$iiy.'aF.irestone-lfcen'sec} ''applicator.: 2:.: ce::Io'ihe'eventaoyJeak should oLctlr.in•th:e:SYStarr,the Pwner.-rtrustglve nbtite'jn Wnting•bf by:tfeiephone to.Firestdne'withfn,thtrtY.{.30}days of:•'.'. :.'ady'utcUrrente of'a:leak::VVr]4eii:notice:may.ba sehtfo'.Frestone.at'the strdk add ressnr:fa t:riudMber:shbWn ai.the'rb4erse.sidi':of this.L'irniteil :. '::Warranty:•'.Evidence.gf.Yhisn'otite shall b'ti the-neteipt by-owner.of.a-.FPrestone:Leak'Nofifi�ation.AcRnuwledgemenk:"By.sO'.notifying'Firestone;_th2.0.Wder :'•aUthonzes FirestorlE or:its designee to.nVOstigafe the:cause of the.Teak•:: :" .:Invgst'iaatiori.'.•Ifuporrinvestigation;;Firestonedeterrjiines.ttiatiheleak.Fs'not.exrlu ad-under.the.Terrns;.Conditions,andtimitatigns:sef•forthinthis:'.' :Red•ShiQld:RgofjngS'y'Stehi•Limited:Warranty.(the"•Ci miteii;Warranty".};.the•Owriet'3.Soleand'g5tlusivstetriedyand'F1r4§tonii'stotdl.fiatiiity.sfi ll,be•;. .limited to-th•Q repair'of'the leaK:Should'the Investigation rQVeaf that'the Jeak is eicgli)ded untle{.the Terms;Contiitioris,and liniitatiprfs;tM,e.Owner'shaU'be': : :rasponsit;te:fof payrtienf.bf.fhe ir)vestigatiori'CostS..•FBifule by.OWiier:to:pay:for-these cosU5sball.'render'this Limited Warfanty.nrllf and void- Firestona:':' advisethe*O,,vn'er.gf.•the'type.dnd/brext'edtof'repairs'requiredtoh4ir;ade:at.th$.Owner's:experise.that..Wil1,pemi iit:this:Lirhite4Wamdnty'.tv:re'rhaih In':::.'::• :•;effect for the:uilexpired',portign:of•its'terin :Failure liy,th'Q.OWnei to:properly,maKe;the'se repairs in a reaso[rdhle mariner•using.'a Frostohe-icensed.:; :.;•: :; •• ••'applicdtorantf•rkithin60days9hallk2rider,thisL'irruted'v✓arranty.r>ull:antl;uoid;:: .' :' ':..'.: " 4.: •:.'pisbiite's::AFiy'dlspute;:controversy:orrJaini•betweeh:tfi¢:Owner'and.J'ireStoiieconcerningthis'J_irriifedWarranty;shall.be:_settled:liy.fnetliatlon.:•In:the •:•. '. :.event ffiat:the 6v¢ner'and FlrestonB do:not TesolVekJfe d sputa,cuntroversy'.6r dairYi:in mediation,.fhe:Owrierarid..Flre9tnne'dgree:that neitherparty.,Wilf. :'•commence or'prosecute:dny suifi$Poeeeding;vr.claim•otfer thoh.IAt1i6.c•'ourts of:}lemiltbri Cofinty in;the state of•Iridia'nal or the:UnitE!4-States:bistrict• ':: : •' :Court,'$oUthern.Distriet of Indiana,.Indianapolis'Division::Each:pa ty irrevocably consents to the jurisd'ictign anii venue of the abpve=identified.courts::'.':.,: :.'.• 5:.'::.:j?avmeht.Reauiretl::Frestone.shall:have ho Wtg'atioriundi r.thi5.LfrNted•-Watrapty'unle5s'bid."untif-Firestgne-a,ndth¢licensed.aPplicafprtia•YE been:.'.;.:'.:•. aitl iri f HI . ...p. u:fOialrrnatetials;:suppli?s;:servPces,:approved wrifterl•cha'ng'e'orders;warGanty.cn'itsJ rid:oth"er•toSis•wkiicti,'gee includea-irj;orincidentdI'to ,:the'::' ' Syste'::In tfie:event•tiiat.rel5a'i notcbvered 6y.this.Liniited:Warranty are necessary.ih'tbe future;Firestone r8sehies:the:ri§fit:ho:susperttl this'Limifed:' ::.Arafrehty,Vhtil'Such'repairs.havebe0n'Co:mplete6'n'djh'eljderlSed.dpplicatpr.anii/orN'restone:hig'fjeen'paid.irifulljursuCFi•repairs.::.':,,':: ::'lxcl}rsfdns.,'F.irestorie'Sha1H•.have.no:obiigaton:untlertfifs mitedWailanty;Or.'aiiyOther:lialii�ity,-66W.'6e-in;th'g:futufe•IfWleak'ordorriage.is:gaused.by;: :. (a):wetUrel(orces;.''aisastei .dr:ectsbfda' inclUding;.but'ngtiiinit6dto;'fiYes;hiuirfpanes,:;c,nadoi2s;hail,.Jy7idblown-d66ris,:Iightgitig;:earthquakla's' .'::'•': volcanic'a'ctivity;atdmJcradia'tion,:insects'&anima fs (b).:NFinds'oFpeakgustspeed:ator.in:ezc'es5'of55.MPH:calculaepat.ton(•SO);rhetarshbovegrounil:;;: .using avallable:meteorological:dati;(c).'Act{s)',:condU'ct or'on jssion(s),by arty perspri,;ocaet(fi):of war,ter�Orism'or'udhdalisLh;whjth••damage,the'System'. :•oc•whidi:impelr.•the:Sysfein's.abili'tYtd resistieaks;'•(d)Fallur6 by;fhe 0wper'te;use reasor;abie:;care•Firrrrairitaininy the5ystem;,said rfiaihtEnaM. .E-•. InclUde,.bUtn�t77e Jim ited.tb;thoseJterns;listed'on'�he reverse.sde.of.this.tirriited.Wdrrantyentitfatl'"B�ilding,l rtyeJope'Gare an"tMalntenance.Guiale"; :(e)•DeterioraYion orfajlure of'build'ing compoAQnts,jnclu�n$;.but.nbt•liriiited to;the roof substrate;WaIL4,mortar,.HVAC units;skyfigtits•etC.;:(f.) Cp.fttrurtinri yeperated;moisture;•coladerisafon:or.infi[trat on of,mbistUr.'e in frorn;:t6roiigll;:or:arpund:fhe walls,cbpir)gsi.rboffop tiardwirB•or,equipment;:::: -skylights;•bUilding:Sirvcture q�uoaerlying:dr surrounding'materials;•.(g);Acid;.'oil',:'harrnfUl chemicals,dr the readtion•hetWe.e.RAhem,(h):Altbratiohsoe- ::repairs to'the•SystEm.that:are nbf.tomplet0d in:accordahce:watt:Fi[esYoriPS pulilished'5peclficatiohB,:r Qt coinplEfed by:ah:3pproveti.c80traCfor:atr %or' not eohipleted.iroittr prgrter'nottce:to firestgne;,'(i).The:desigri of;the roofing sysfein:'Firestpne•d'oes not.iindeitalce',any.Anaiysis:of the architecture br:::. : engineering':regUirQetoevaluate•whaYtype.of-System.is:a"pprgp'riaie:for-building.and:rrral(es•nb.vJarrbhbt 0zpres5'.orF'plied.asto'the'suitability df it's:: Products.for any'•partiGtilaf.structur ;:sucli:a.deter[niriation•s t#ie•fespon5ibility of.t#le.arctiitQSE;;erigineer•.or;des gn'Pr4fe'ss onal;'.6j:Iiriproper'.selec4lon of.:: - :'• niaferials f6r•the'roof:asserribiy'dr.the fallur9 to accurately caJ4ulate'�gfnd uplift anpjor rctofloaAs;(k')'DeCeriorativn tb7iietai".roofing rriateriZM;lan. accessories,caused by mjrine salt•'water•'atindsphere,'or by•reg0iar:spray.of:eitisersaltOrfresh water;:orv;.(I.)Change in'buijdirtg-6se"orPurpose.:• :'.". : ::• 6.. Tr feP.:.This Limited.Warranty:shall•6e'Gnsferdtile.sublecCto'Owner's'payiner5tofthecurrentttansfetfee$etbyFiCestOl7e:• "•. 7: ..:Term;T.ha•Yerm.offhis[Imited.lyarranty.shall.be fqr.the,period set•fgrtFi'above and:such term:shall not.be•extended under••any.circumstances . Robe Access. Duhng tfie term of this Lmited Warranty;firestone's,'-destgnated.represetitative br rppfoyeas shall-hay:,frae'access Yo-tlie roof dijripg: -regular business.hours.-,Iri.the event.that-roof acCess'is'Gmited:due•to security orrother:restrictigris;Owher:strafl:reimburse F restorie for.'all reasonable':' :'. :: cost iridurrad-driring;Hnspecti-crtand(bF r.'epair:of the:5y5fem,that are'dire 1'o,deliys a'ssbtiited with said:res[dctions.:;Owner:shah lie,re'spanslhie.for:the: ::'dariiSge:caused:by;rer?invai:and replacerttenEof.a ydverburtlen5;.sup2rstraka4r.oyerlay5,•either•peTmaneotortemporary;,eXcllidingace0pted'stoite: JiallasEor'parer's,'asnecissarytaexposQtbe.system;forinspecffph'.and%or:rep air:•.::' :'.• 9.:.'. . iirer..1ii[e5tone's.faifU[e:toenfore0anyof'kheterms'orcopdRipns'Stated'-' ernshaH'nothe:tonstrued-as-arvdiV$r:afsUchprovisiom'orofany;other::.'••:.:.•:: •. temu:and.copditions of t�iis.lirrlited-WarYanfy.:. "' ' ••' 10::,;GOVernihu'Law: :TNis:LiFnitEd Warranty shall be.ygverried'by.ard•construed:in:accoriJance;witirthE}aWS:of the1 �*eofIndian'a!wiihoutregar 69'tha't":. Stdte's.rufes'oh.conflict•bfja'Vs.•' Severabilitil.•If any-portion.of.this:Limited•Warrbnty:is held by'a court of com patent,jurisdiction'tq'be invalid;-void•or.unenforceabid,-the remaining.I:. jt[ovjsiorrs'shali ne'vertheles 'continrie iii'fuil,force.::: •::FI.RE$FONE�DOES.NiID7'WA{2RANT PRODUCTS INCl3RpORATED'OR.UTII:IZED IN'THIS"INSTJ(LLATIdN IfHAT.1NERE'NOT•'FLIRIVISHED:LaYF.IRESTON�:::.'•:�..:•�.'•':.'' FI9 TONE.SPEI;`MdAL'LY•LifSCLAI'MS:LI.ABILITI iA0E•RANYTHEORY'.OF.LAW AR•ISINGQUT-OF;Tki INSTALLkYION:Of.;.PEFiRJAMANCE.Of,:OR• •''DAMAGES•S:IJSTAIfVED'By•OR GAUSED:BY;'PRODUC7 S NOT1=l1RNISFIEO.6YFIRESTONE::..:•.'.:.•.:'.::.:'.'::••':.'.'..:•''.'.•.:::::.•.'.;., : ..::•. ..::::::''.'::•'': •THIS LIMI-tO.WARRANTY-S)PERSED.ES'AND:I5•IR'LIEU'OFALVOYHER WAitRA-NTiEi 6F-: ERGHANTA8I1,11Y.AND;FI7f%VE55:FOR'A AR7ICl1LAR, ':,;P1Jl'ZPQSEiAND:FfR STONE7-IEREB,YDISC:LAIMSE11-iSVbRWARi2ANTIQS:,•T.FiiSClj�ITEci-*. i ANT.Y-. HOA,L.gE.Ti1F,•01yi11ER'S'SOirE.RND;EkCLUSIV.E':.' •:: -.REM'EbY-"AGAINST.FIRESTOIJE,AND.FIRESTONE SHALL M)T-BE LIA6LE.FOR.ANY CONSEQ.UENTIAC;'Sp€CIAL•;.IIJOIDENTAL'OW-OTHER DAMAGES::' ::INCLUDING;WT.NOT:L•Ih1ITED 7p,t6SSS.OF PROFITS:OR-DAMAGES TO THE.BUIeDINGOR iTS•CONT.ENTS OR THE ROOF:DECI<..:THIS LIMITED.:':.•:.'•:•:••'. :WkRRANTY'CANNOT:BE.AFIENDED/A;LTER 1)OR MODIFSf D IiV;6iNY:WJA('ES(CEPT'IN.WRITINGSFE ED.BY.AN AUTM.ORI—Ep'.DFFIOE6t;OF'F;If2ESTONE:•(SO,:. "O3 HER PLRSEIN HAS AN1':AUTHORITY:TO BIND'FIRESTONVE Wi-rH-ANY,REP.RBSENTATIDN OR'WAFIRANTf`'WHETROR-0114L OR WitIT7EN:: FIRE SON UI DIfYGPROD CTS CQNIP.ANY'.LLC. '' . . .. S AMPLE :AliYigna are liorlietl:, :.'. . . Tine:: BUILDING ENVELOPE CARE AND MAINTENANCE GUIDE (For Red Shield Warranted Roofing Systems) Congratulations on your purchase of a Firestone Roofing System! Your roof is a valuable asset that should be properly maintained. All roofs and roofing systems require periodic inspection and maintenance to perform as designed and to keep your Limited Warranty in full force and effect. 1. The roof should be inspected at least twice yearly and after any severe storms.A record of all inspection and maintenance activities should be maintained, including a listing of the date and time of each activity as well as the identification of the parties performing the activity. 2. Proper maintenance and good roofing practice require that ponded water(defined as water standing on the roof forty-eight hours after it stops raining) not be allowed on the roof. Roofs should have slope to drain,and all drain areas must remain clean. Bag and remove all debris from the roof since such debris can be quickly swept into drains by rain. This will allow for proper water run-off and avoid overloading the roof. 3. The Firestone Roofing System should not be exposed to acids,solvents,greases,oil,fats,chemicals and the like. If the Firestone Roofing System is in contact with any such materials,these contaminants should be removed immediately and any damaged areas should be inspected by a Firestone Licensed Applicator and repaired if necessary. 4. The Firestone Roofing System is designed to be a waterproofing membrane and not a traffic surface. Roof traffic other than periodic traffic to maintain rooftop equipment and conduct periodic inspections should be prohibited.In any areas where periodic roof traffic may be required to service rooftop equipment or to facilitate inspection of the roof, protective walkways should be installed by a Firestone Licensed Applicator as needed to protect the roof surface from damage. 5. Some Firestone roofing membranes require maintenance of the surface of the membrane: a. Smooth-surfaced Firestone APP membranes should be coated with an approved liquid coating,such as Firestone Aluminum Roof Coating or Firestone AcryliTop applied in accordance with Firestone specifications, in order to maximize the service life of the membrane. If this coating is not applied as part of the initial roofing installation,it should be applied within the first five years after the roof is installed to help protect the membrane from surface crazing and cracking. In addition,this coating should be maintained as needed to re- coat any areas that have blistered, peeled or worn through. b. Granule-surfaced Firestone APP and SBS membranes do not normally require surface maintenance other than periodic inspection for contaminants,cuts or punctures. If areas of granular loss are discovered during inspection,these areas should be coated with Firestone AcryliTop or other Firestone-approved coating applied in accordance with Firestone specifications. C. Gravel-surfaced Firestone BUR membranes do not normally require surface maintenance other than periodic inspection for contaminants or damage. If areas of gravel loss are discovered during inspection,gravel must be reinstalled into hot asphalt to protect the surface of the membrane. Coatings on smooth surface BUR membranes must be maintained as needed to re-coat any areas that have blistered,peeled or worn through. d. Firestone EPDM and TPO roofing membranes do not normally require surface maintenance other than periodic inspection for contaminants,cuts or punctures. Occasionally,approved liquid roof coatings,such as Firestone AcryliTop,are applied to the surface of EPDM membranes in order to provide a lighter surface color. Such coatings do not need to be maintained to assure the performance of the underlying EPDM roof membrane, but some maintenance and re-coating may be necessary in order to maintain a uniform surface appearance. e. Firestone Una-Clad metal roofing panels and trim do not normally require surface maintenance other than periodic inspection for contaminants or damage. In addition,periodic cleaning of the surface may be required to remove dirt and maintain the aesthetic appearance of the coated metal. Simple washing with plain water using hoses or pressure spray equipment is usually adequate. If cleaning with agents other than water is contemplated,several precautions should be observed: (1)do not use wire brushes,abrasives,or similar cleaning tools which will mechanically abrade the coating surface,and(2)cleaning agents should be tested in an inconspicuous area before use on a large scale. 6. All metal work, including counter-flashings, drains, skylights, equipment curbs and supports, and other Firestone brand rooftop accessories must be properly maintained at all times. Particular attention should be paid to sealants at joints in metal work and flashings. If cracking or shrinkage is observed, the joint sealant should be removed and replaced with new sealant. 7. Any alterations to the roof, including but not limited to roof curbs, pipe penetrations, roof-mounted accessories, and tie-ins to building additions must be performed by a licensed Firestone Licensed Applicator and reported to Firestone. Additional information and reporting forms for roof alterations are available at www.firestonebpco.com. 8. Should you experience a leak: (a) Check for the obvious: clogged roof drains, loose counterflashings, broken skylights, open grills or vents, broken water pipes. (b) Note conditions resulting in leakage. Heavy or light rain, wind direction, temperature and time of day that the leak occurs are all-important clues to tracing roof leaks. Note whether the leak stops shortly after each rain or continues to drip until the roof is dry. If you are prepared with the facts,the diagnosis and repair of the leak can proceed more rapidly. (c) Contact Firestone Warranty Claims at 1-800-830-5612 as soon as possible...but please don't call until you are reasonably sure that the Firestone Roofing System is the cause of the leak. Firestone feels that the preceding requirements will assist you,the building owner,in maintaining a watertight roof for many years. Your roof is an investment,and maintenance is essential to maximize your return on this important investment. rtisestene BUILDING PRODUCTS NOBODY COVERS YOU BETTER TM 250 West 96th St.,Indianapolis, IN 46260 1-800-428-4442•1-317-575-7000 •www.firestonebpco.com International Offices: Canada: 2835 Argentia Road,Unit#2 •Mississauga,ON L5N 8G6 •800-428-4442•www.firestonebpco.ca Europe: Hermesstraat 2C-1930 •Zaventem,Brussels,Belgium •+32 2 7114450•www.firestonebpco.com Latin America: 8300 NW 53rd Street,Suite#106•Miami,FL 33166 •305-471-0117•www.firestonebpco.com 10/11 —Item#815(Replaces 07/08)-01 UltraPlyTM'TPO Membrane&Flashing Series Safety Data Sheet Firestone Building Products Company Section 1: Identification of.the Substance/Mixture and of the.Company/Undertaking 1.1 Product identifier Product Name • UltraPlyTm TPO Membrane & Flashing Series Synonyms . UltraPlyTm TPO 18" Curb Flashing, UltraPlyTm TPO Custom Accessories, UltraPlyTM TPO Reinforced Split Pipe Boot, UltraPlyTm TPO Walkway Pad, UltraPly'rm TPO T- Joint Cover; UltraPlyTm TPO Inside/Outside Molded Corner, UltraPlyTm TPO Universal Pipe Flashing, UltraPlyTm TPO Large Pipe Flashing, UltraPly'rm TPO Unsupported Flashing, UltraPly rm TPO Coated Metal; UltraPlyTm TPO Membrane, UltraPlyTm TPO XR T Membrane, UltraPlyTm TPO PlatinumTM Membrane, UltraPlyTm TPO Reinforced Cover Strip, UltraPlyTm TPO Reinforced Curb Corner 1.2 Relevant identified uses of the substance or mixture and uses advised against Relevant identified use(s) . Construction:Roofing Material 1.3 Details of the supplier of the safety data sheet Manufacturer . Firestone Building Products Company 250 West 96th Street Indianapolis, IN 46260 United States firestonemsds@bfdp.com Telephone (General) . 800-428-4442 1.4 Emergency telephone number Manufacturer . (800) 424-9300 - CHEMTREC Manufacturer . (703) 527-3887 - CHEMTREC - International Section 2i Hazards Identification EU/EEC According to EU Directive 1272/2008 (CLP)/REACH 1907/2006 [amended by 453/2010] According to EU Directive 67/548/EEC (DSD) or 1999/45/EC (DPD) 2.1 Classification of the substance or mixture CLP . Not classified DSD/DPD . Not classified 2.2 Label Elements CLP Hazard statements • No label element(s) required DSD/DPD Risk phrases . No label element(s) required 2.3 Other Hazards Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 1 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyTM TPO Membrane&Flashing Series CLP . This material is exempt from CLP/REACH obligations as an article as specified in REACH (1907/2006) and related ECHA guidance. DSD/DPD . Under European Directive 1999/45/EC these product(s) are exempt and considered manufactured article(s) under stated normal conditions of use. United States (US) According to OSHA 29 CFR 1910.1200 HCS 2.1 Classification of the substance or mixture OSHA HCS 2012 . Not classified 2.2 Label elements OSHA HCS 2012 Hazard statements . No label elements(s) required 2.3 Other hazards OSHA HCS 2012 . Under United States Regulations (29 CFR 1910.1200 - Hazard Communication Standard) this product is exempt as an article under stated normal conditions of use. Canada According to WHMIS 2.1 Classification of the substance or mixture WHMIS . Not classified 2.2 Label elements WHMIS . No label element(s) required 2.3 Other hazards WHMIS . Under Canadian regulations (Workplace Hazardous Materials Information System (WHMIS)- Hazardous Products Act (HPA), Section 11(1)), these product(s) are exempt and considered manufactured article(s) under stated normal conditions of use. 2.4 Other information . This material, as an article, does not legally require an SDS. See Section 12 for Ecological Information. Section 3 - Composition/information:on Ingredients. .- 3.1 Substances . Material does not meet the criteria of a substance in accordance with Regulation (EC) No 1272/2008. 3.2 Mixtures Non-Hazardous Com onents Chemical Name Identifiers I%(weight)I LD50/LC501 Classifications According to Regulation/Directive rN omments EU DSD/DPD: None Nonhazardous Components NDA 1100% NDA EU CLP: None DA Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 2 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyT TPO Membrane&Flashing Series I I I I I OSHA HCS 2012: None I See Section 11 for Toxicological Information. Section 4 -First Aid Measures 4.1 Description of first aid measures Inhalation . First aid is not expected to be necessary if material is used under ordinary conditions and as recommended. If signs/symptoms develop, move person to fresh air. Administer oxygen if breathing is difficult. Give artificial respiration if victim is not breathing. If signs/symptoms continue, get medical attention. Skin . First aid is not expected to be necessary if material is used under ordinary conditions and as recommended. Wash skin with soap and water. If signs/symptoms develop, get medical attention. Eye . First aid is not expected to be necessary if material is used under ordinary conditions and as recommended. If contact with material occurs flush eyes with water. If signs/symptoms develop, get medical attention. Ingestion . First aid is not expected to be necessary if material is used under ordinary conditions and as recommended. If signs/symptoms develop, get medical attention. 4.2 Most important symptoms and effects, both acute and delayed . Refer to Section 11 -Toxicological Information. 4.3 Indication of any immediate medical attention and special treatment needed Notes to Physician . All treatments should be based on observed signs and symptoms of distress in the patient. Consideration should be given to the possibility that overexposure to materials other than this product may have occurred. Section .5 =Firefighting.Measures 5.1 Extinguishing media Suitable Extinguishing Media . Water, foam, dry chemical, carbon dioxide (CO2). Unsuitable Extinguishing . None known. Media 5.2 Special hazards arising from the substance or mixture Unusual Fire and Explosion . Does not present any special fire or explosive hazards. Hazards Hazardous Combustion . Upon reaching temperatures of combustion, produces corrosive and/or toxic fumes. Products 5.3 Advice for firefighters . Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA)with a full face-piece operated in positive pressure mode. Structural firefighters' protective clothing will only provide limited protection. Section 6 -Accidental Release Measures 6.1 Personal precautions, protective equipment and emergency procedures Personal Precautions . No special precautions expected to be necessary if material is used under ordinary conditions and as recommended. Emergency Procedures . No emergency procedures are expected to be necessary if material is used under ordinary conditions as as recommended. Use normal clean up procedures. Preparation Date: 15/Augustf2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 3 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyTm TPO Membrane 8 Flashing Series 6.2 Environmental precautions . No special precautions necessary. 6.3 Methods and material for containment and cleaning up Containment/Clean-up . Pick up pieces and place in container or bag for disposal. Measures 6.4 Reference to other sections . Refer to Section 8 - Exposure Controls/Personal Protection and Section 13 - Disposal Considerations. Section 7 =Handling and Storage 7.1 Precautions for safe handling Handling . Use good safety and industrial hygiene practices. 7.2 Conditions for safe storage, including any incompatibilities Storage . Store in a cool, dry, well-ventilated place. 7.3 Specific end use(s) . Refer to Section 1.2 - Relevant identified uses. Section 8 -.Exposure Controls/Personal Protection 8.1 Control parameters Exposure Limits/Guidelines . No exposure limits/guidelines available for the material or the components. 8.2 Exposure controls Engineering . Under normal conditions of use, special ventilation is not required. Measures/Controls Personal Protective Equipment Respiratory . No respiratory protection is required under normal conditions of use. Eye/Face . Under normal conditions of use, eye protection is not required. Skin/Body . No skin protection is ordinarily required under normal conditions of use. Environmental Exposure . Follow best practice for site management and disposal of waste. Controls Key to abbreviations STEL =Short Term Exposure Limits are based on 15-minute exposures ACGIH=American Conference of Governmental Industrial Hygiene STEV =Short Term Exposure Value NIOSH=National Institute of Occupational Safety and Health TWAEV=Time-Weighted Average Exposure Value OSHA =Occupational Safety and Health Administration TWA _Time-Weighted Averages are based on 8h/day,40h/week exposures Section 9 - Physical and. Chemical Properties 9.1 Information on Physical and Chemical Properties Material Description Black and white sheet,white and gray sheet,tan and gray sheet, Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 4 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyTM TPO Membrane&Flashing Series Physical Form Solid Appearance/Description gray and gray sheet,white sheet with fleece back membrane,white sheet,grey sheet, or tan sheet. Essentially no odor. Color Black,white,gray,and tan. Odor None Odor Threshold None General Properties Boiling Point Not relevant Melting Point Data lacking Decomposition Temperature Data lacking pH Not relevant Specific Gravity/Relative Density 0.94 Water--1 Water Solubility Insoluble Viscosity Not relevant Explosive Properties Not relevant. Oxidizing Properties: Not relevant. Volatility Vapor Pressure Not relevant Ivapor Density Not relevant Evaporation Rate Not relevant Flammability Flash Point Not relevant UEL Not relevant LEL Not relevant Autoignition Not relevant Flammability(solid,gas) Not flammable. Environmental Octanol/Water Partition coefficient jDatalacking 9.2 Other Information No additional physical and chemical parameters noted. Section 10: Stability and Reactivity 10.1 Reactivity No dangerous reaction known under conditions of normal use. 10.2 Chemical stability Stable under normal temperatures and pressures. 10.3 Possibility of hazardous reactions Hazardous polymerization will not occur. 10.4 Conditions to avoid No data available 10.5 Incompatible materials No data available. 10.6 Hazardous decomposition products Thermal decomposition could produce CO, CO2, and Oxides of Nitrogen. Section 11 -Toxicological Information 11.1 Information on toxicological effects Other Material Information . This material is an article that does not release or otherwise result in exposure to a hazardous chemical under normal use. The information provided below is for components only and is not expected to be applicable to the material as a whole. Preparation Date:15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date:077May/2013 Page 5 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyT""TPO Membrane&Flashing Series GHS Properties Classification EU/CLP.Not relevant Acute toxicity OSHA HCS 2012.Not relevant EU/CLP.Not relevant Aspiration Hazard OSHA HCS 2012.Not relevant Carcinogenicity EU/CLP-Not relevant OSHA HCS 2012.Not relevant EU/CLP.Not relevant Germ Cell Mutagenicity OSHA HCS 2012.Not relevant EU/CLP.Not relevant Skin corrosion/Irritation OSHA HCS 2012.Not relevant Skin sensitization EU/CLP.Not relevant OSHA HCS 2012.Not relevant STOT-RE EU/CLP-Not relevant OSHA HCS 2012.Not relevant STOT-SE EU/CLP.Not relevant OSHA HCS 2012.Not relevant EU/CLP-Not relevant Toxicity for Reproduction OSHA HCS 2012.Not relevant EU/CLP.Not relevant Respiratory sensitization OSHA HCS 2012.Not relevant EU/CLP-Not relevant Serious eye damage/Irritation OSHA HCS 2012.Not relevant Potential Health Effects Inhalation Acute (Immediate) . Under normal conditions of use, no health effects are expected. Chronic (Delayed) . Under normal conditions of use, no health effects are expected. Skin Acute (Immediate) . Under normal conditions of use, no health effects are expected. Chronic (Delayed) . Under normal conditions of use, no health effects are expected. Eye Acute (Immediate) . Under normal conditions of use, no health effects are expected. Chronic (Delayed) . Under normal conditions of use, no health effects are expected. Ingestion Acute (Immediate) . Under normal conditions of use, no health effects are expected. Chronic (Delayed) . Under normal conditions of use, no health effects are expected. Section:12 - Ecological Information 12.1 Toxicity . Material data lacking. 12.2 Persistence and degradability Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 6 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyTm TPO Membrane&Flashing Series . Material data lacking. 12.3 Bioaccumulative potential . Material data lacking. 12.4 Mobility in Soil . Material data lacking. 12.5 Results of PBT and vPvB assessment . PBT and vPvB assessment has not been carried out. 12.6 Other adverse effects . Material data lacking. Section 13 - Disposal,Considerations 13.1 Waste treatment methods Product waste . Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. Packaging waste . Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. Section 14-Transport Information 14.1 UN 14.2 UN proper 14.3 Transport hazard 14.4 Packing 14.5 Environmental number shipping name class(es) group hazards DOT NDA Not Regulated NDA NDA NDA TDG NDA Not Regulated NDA NDA NDA IMO/IMDG NDA Not Regulated NDA NDA NDA ADN NDA Not Regulated NDA NDA NDA ADRIRID NDA Not Regulated NDA NDA NDA IATA/ICAO NDA Not Regulated NDA NDA NDA 14.6 Special precautions for . None known. user 14.7 Transport in bulk . Not relevant. according to Annex II of MARPOL 73/78 and the IBC Code Section 15- Regulatory Information 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture SARA Hazard Classifications . None Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date:07/May/2013 Page 7 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyTM TPO Membrane&Flashing Series State Rig ht To Know . Component CAS MA NJ PA Nonhazardous NDA No No No Components Inventory Component CAS Canada DSL Canada NDSL China EU EINECS EU ELNICS Nonhazardous NDA No No No No No Components Inventory Con- - Component CAS TSCA Nonhazardous NDA No Components Canada Labor Canada-WHMIS-Classifications of Substances Not Listed Canada-WHMIS-Ingredient Disclosure List Not Listed Environment Canada-CEPA-Priority Substances List Not Listed China Other China-Annex I&11-Controlled Chemicals Lists Not Listed Europe Other EU-CLP(1272/2008)-Annex VI-Table 3.2-Classification Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Concentration Limits Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Labelling Not Listed Preparation Date, 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 8 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyTM TPO Membrane&Flashing Series EU-CLP(1272/2008)-Annex VI-Table 3.2-Notes-Substances and Preparations Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Safety Phrases Not Listed EU-Hazardous Substances Restricted or Prohibited in Electrical Equipment(2002/95/EC)(RoHS) Not Listed EU-Inventory of Cosmetic Ingredients Directive(INCI)(76/768/EEC)-Other Ingredients Not Listed EU-Inventory of Cosmetic Ingredients Directive(INCI)(76/768/EEC)-Perfume and Aromatic Materials Not Listed Germany Labor Germany-Immission Control-Qualifying Quantities for Major Accident Prevention Not Listed Germany-Immission Control -Qualifying Quantities for Safety Reporting Not Listed Germany-TRGS 505-Specific Lead Regulations Not Listed Germany-TRGS 511 -Specific Ammonium Nitrate Regulations Not Listed Environment Germany-TA Luft-Types and Classes Not Listed Germany-TA Luft-Emission Limits for Carcinogenic Substances Not Listed Germany-TA Luft-Emission Limits for Fibers Not Listed Germany-TA Luft-Emission Limits for Inorganic Dusts Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 9 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyTM TPO Membrane&Flashing Series Not Listed Germany-TA Luft-Emission Limits for Inorganic Gases Not Listed Germany-TA Luft-Emission Limits for Organic Substances Not Listed Germany-Water Classification(VwVwS)-Annex 1 Not Listed Germany-Water Classification (VwVwS)-Annex 2-Water Hazard Classes Not Listed Germany-Water Classification (VwVwS)-Annex 3 Not Listed United States Labor U.S.-OSHA-Process Safety Management-Highly Hazardous Chemicals Not Listed U.S.-OSHA-Specifically Regulated Chemicals Not Listed Environment U.S.-CAA(Clean Air Act)-1990 Hazardous Air Pollutants Not Listed U.S.-CERCLA/SARA-Hazardous Substances and their Reportable Quantities Not Listed U.S.-CERCLA/SARA-Radionuclides and Their Reportable Quantities Not Listed U.S.-CERCLA/SARA-Section 302 Extremely Hazardous Substances EPCRA RQs Not Listed U.S.-CERCLA/SARA-Section 302 Extremely Hazardous Substances TPQs Not Listed Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 10 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyT'TPO Membrane&Flashing Series U.S.-CERCLA/SARA-Section 313-Emission Reporting Not Listed U.S.-CERCLA/SARA-Section 313-PBT Chemical Listing Not Listed United States -California Environment U.S.-California-Proposition 65-Carcinogens List Not Listed U.S.-California-Proposition 65-Developmental Toxicity Not Listed U.S.-California-Proposition 65-Maximum Allowable Dose Levels(MADL) Not Listed U.S.-California-Proposition 65-No Significant Risk Levels(NSRL) Not Listed U.S.-California-Proposition 65-Reproductive Toxicity-Female Not Listed U.S.-California-Proposition 65-Reproductive Toxicity-Male Not Listed United States - Pennsylvania Labor U.S.-Pennsylvania-RTK(Right to Know)-Environmental Hazard List Not Listed U.S.-Pennsylvania-RTK(Right to Know)-Special Hazardous Substances Not Listed 15.2 Chemical Safety Assessment Chemical Safety Assessment is not required. Section 1-6.-:Other Information Preparation Date: 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 11 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPlyl TPO Membrane&Flashing Series Last Revision Date . 07/May/2013 Preparation Date . 15/August/2011 Disclaimer/Statement of . The information contained herein is based on data considered accurate which has Liability been obtained from other companies and organizations. However, no warranty or representation is expressed or implied that the information, is accurate, complete or representative. Firestone Building Products Company, LLC assumes no responsibility for injury to the buyer, the buyer's employees, or any third persons, if reasonable safety procedures are not followed. Additionally, Firestone Building Products Company assumes no responsibility for injury to buyer, the buyer's employees, or any third persons caused by abnormal use of this material, even if reasonable safety procedures are followed. Key to abbreviations NDA=No Data Available Preparation Date. 15/August/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 07/May/2013 Page 12 of 12 WHMIS,EU DSD/DPD,EU CLP,OSHA HCS 2012 UltraPly Bonding Adhesive Safety Data Sheet Firestone Building Products Company Section 1: Identification of the Substance/Mixture and of"the.Company/Undertaking 1.1 Product identifier Product Name • UltraPly Bonding Adhesive Synonyms . TPO Bonding Adhesive 5G; UltraPly TPO Bonding Adhesive SDS Number/Grade . FS-025 1.2 Relevant identified uses of the substance or mixture and uses advised against Relevant identified use(s) . Adhesive 1.3 Details of the supplier of the safety data sheet Manufacturer . Firestone Building Products Company 250 West 96th Street Indianapolis, IN 46260 United States firestonemsds@bfdp.com Telephone (General) . 800-428-4442 1.4 Emergency telephone number Manufacturer . (800)424-9300 - CHEMTREC Manufacturer . (703) 527-3887 - CHEMTREC - International [Section 2: Hazards Identification: EU/EEC According to Regulation (EC) No 1272/2008 (CLP)/REACH 1907/2006 [amended by 453/2010] According to EU Directive 67/548/EEC (DSD) or 1999/45/EC (DPD) 2.1 Classification of the substance or mixture CLP . Flammable Liquids 2 - H225 Skin Irritation 2 - H315 Eye Irritation 2 - H319 Specific Target Organ Toxicity Single Exposure 3: Narcotic Effects - H336 Reproductive Toxicity 2 - H361 d Specific Target Organ Toxicity Repeated Exposure 2 - H373 Hazardous to the aquatic environment Chronic 3 - H412 DSD/DPD . Highly Flammable (F) Irritant (Xi) Harmful (Xn) Substances Toxic To Reproduction - Category 3 R11, R38, R48/20, R63, R65, R67, R52, R53 2.2 Label Elements CLP DANGER Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 1 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive Hazard statements • H225 - Highly flammable liquid and vapour H315 - Causes skin irritation H319 - Causes serious eye irritation H336 - May cause drowsiness or dizziness H361d - Suspected of damaging the unborn child. H373 - May cause damage to organs- Central Nervous System (CNS)through prolonged or repeated exposure via Inhalation H412 - Harmful to aquatic life with long lasting effects Precautionary statements Prevention . P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, sparks, open flames and/or hot surfaces. - No smoking. P233 - Keep container tightly closed. P240 - Ground and/or bond container and receiving equipment. P241 - Use explosion-proof electrical/ventilating/lighting/equipment. P242 - Use only non-sparking tools. P243 -Take precautionary measures against static discharge. P260 - Do not breathe mist, vapours, spray. P264 -Wash thoroughly after handling. P271 - Use only outdoors or in a well-ventilated area. P273 -Avoid release to the environment. P280 -Wear protective gloves/protective clothing/eye protection/face protection. P281 - Use personal protective equipment as required. Response . P370+P378 - In case of fire: Use appropriate media for extinction. P304+P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P312 - Call a POISON CENTER or doctor/physician if you feel unwell. P303+P361+P353 - IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P321 - Specific treatment, see supplemental first aid information. P332+P313 - If skin irritation occurs: Get medical advice/attention. P362 -Take off contaminated clothing and wash before reuse. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337+P313 - If eye irritation persists: Get medical advice/attention. P314 - Get medical advice/attention if you feel unwell. P308+P313 - IF exposed or concerned: Get medical advice/attention. Storage/Disposal . P235 - Keep cool. P403+P233 - Store in a well-ventilated place. Keep container tightly closed. P501 - Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. Supplemental information . 25-35 percent of this product consists of an ingredient of unknown toxicity. DSD/DPD NONE Risk phrases • R11 - Highly flammable. R38 - Irritating to skin. R48/20 - Harmful: danger of serious damage to health by prolonged exposure through inhalation. R50 -Very toxic to aquatic organisms. R51 - Toxic to aquatic organisms. R52 - Harmful to aquatic organisms. R53 - May cause long-term adverse effects in the aquatic environment. R62 - Possible risk of impaired fertility. R63 - Possible risk of harm to the unborn child. R65 - Harmful: may cause lung damage if swallowed. Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 2 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive R67 -Vapours may cause drowsiness and dizziness. Safety phrases • S9 - Keep container in a well ventilated place S16 - Keep away from sources of ignition - No Smoking. S37 -Wear suitable gloves. S57 - Use appropriate containment to avoid environmental contamination. 2.3 Other Hazards CLP • According to Regulation (EC) No. 1272/2008 (CLP)this material is considered hazardous. DSD/DPD . According to European Directive 1999/45/EC this preparation is considered dangerous. United States (US) According to OSHA 29 CFR 1910.1200 HCS 2.1 Classification of the substance or mixture OSHA HCS 2012 • Flammable Liquids 2 - H225 Acute Toxicity Oral 4 - H302 Skin Irritation 2 - H315 Eye Irritation 2A- H319 Specific Target Organ Toxicity Single Exposure 3: Narcotic Effects- H336 Carcinogenicity 2 - H351 Reproductive Toxicity 2 - H361 Specific Target Organ Toxicity Repeated Exposure 2 - H373 2.2 Label elements OSHA HCS 2012 DANGER * <i> <$> Hazard statements • Highly flammable liquid and vapour- H225 Harmful if swallowed - H302 Causes skin irritation - H315 Causes serious eye irritation - H319 May cause drowsiness or dizziness - H336 Suspected of causing cancer. - H351 Suspected of damaging fertility or the unborn child. - H361 May cause damage to organs (Central Nervous System/CNS)through prolonged or repeated exposure - H373 Precautionary statements Prevention • Obtain special instructions before use. - P201 Do not handle until all safety precautions have been read and understood. - P202 Keep away from heat, sparks, open flames and/or hot surfaces. - No smoking. - P210 Keep container tightly closed. - P233 Ground and/or bond container and receiving equipment. - P240 Use explosion-proof electrical/ventilating/lighting/equipment. - P241 Use only non-sparking tools. - P242 Take precautionary measures against static discharge. - P243 Do not breathe mist, vapours, spray. - P260 Wash thoroughly after handling. - P264 Do not eat, drink or smoke when using this product. - P270 Use only outdoors or in a well-ventilated area. - P271 Wear protective gloves/protective clothing/eye protection/face protection. - P280 Response • In case of fire: Use appropriate media for extinction. - P370+P378 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. - P304+P340 Call a POISON CENTER or doctor/physician if you feel unwell. - P312 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 3 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive water/shower. - P303+P361+P353 Specific treatment, see supplemental first aid information. - P321 Take off contaminated clothing and wash before reuse. - P362 If skin irritation occurs: Get medical advice/attention. - P332+13313 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. - P305+P351+13338 If eye irritation persists: Get medical advice/attention. - P337+P313 Rinse mouth. - P330 Get medical advice/attention if you feel unwell. - P314 IF exposed or if you feel unwell: Call a POISON CENTER or doctor/physician. - P309+P311 Storage/Disposal e Keep cool. - P235 Store in a well-ventilated place. Keep container tightly closed. - P403+P233 Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. - P501 Supplemental information • 25-35 percent of this product consists of an ingredient of unknown toxicity. 2.3 Other hazards OSHA HCS 2012 . Under United States Regulations (29 CFR 1910.1200 - Hazard Communication Standard), this product is considered hazardous. Canada According to WHMIS 2.1 Classification of the substance or mixture WHMIS . Flammable Liquids- B2 Other Toxic Effects- D2A Other Toxic Effects - 131213 2.2 Label elements WHMIS � T Flammable Liquids - 132 Other Toxic Effects- D2A Other Toxic Effects- D213 2.3 Other hazards WHMIS . In Canada, the product mentioned above is considered hazardous under the Workplace Hazardous Materials Information System (WHMIS). 2.4 Other information NFPA Fir* Instability i HeaNh Special See Section 12 for Ecological Information. Section 3 - Composition/Information_on Ingredients 3.1 Substances Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 4 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive • Material does not meet the criteria of a substance in accordance with Regulation (EC) No 1272/2008. 3.2 Mixtures Composition Chemical Name Identifiers % LD50/LC50 Classifications According to Comments Regulation/Directive EU DSD/DPD: Annex I:F, R11; Repr.Cat.3, R63; Ingestion/Oral-Rat Xn, R48/20-65;Xi, R38, R67 CAS:108-88-3 34% LD50•636 mg/kg EU CLP: Annex VI: Flam. Liq.2, H226;Repr.2, Toluene EC TO Inhalation-Rat LC50• H361d;Asp.Tox. 1, H304;STOT RE 2*, H373; NDA Number:203- 44% 49 g/m'4 Hour(s) Skin Irrit.2, H315;STOT SE 3, H336 625-9 Skin-Rabbit LD50• OSHA HCS 2012: Flam. Liq.2; Repr.2;Acute 14100 NUkg Tox.4(Oral);STOT SE 3: Narc.;Asp.Tox. 1; STOT RE 2(CNS) CAS:64741-84- EU DSD/DPD: Annex I:Carc. Cat.2; R45; Muta. Solvent-refined 0 25% Cat.2;R46;Xn; R65 light petroleum EC TO NDA EU CLP: Annex VI:Carc. 1B, H350; Muta. 1B, NDA naphtha Number:265- 35% H340;Asp.Tox. 1, H304 086-6 OSHA HCS 2012: Data lacking EU DSD/DPD: Not Classified-Classification criteria not met Polymers NDA 5%TO NDA EU CLP: Not Classified-Classification criteria not NDA 15/o met OSHA HCS 2012: Not Classified-Classification criteria not met EU DSD/DPD: Not Classified-Classification criteria not met 1,3-Butadiene,2- CAS:9010-98-4 <12% Ingestion/Oral-Rat EU CLP: Not Classified-Classification criteria not NDA chloro-,polymers LD50•>40 g/kg met OSHA HCS 2012: Not Classified-Classification criteria not met CAS:67-64-1 Ingestion/Oral-Rat EU DSD/DPD: Annex I: F, R11,Xi; R36; R66; R67 EC 5%TO LD50•5800 mg/kg EU CLP: Annex VI: Flam. Liq.2, H226; Eye Irrit.2, Acetone Number:200- 10% Inhalation-Rat LC50• H319;STOT SE 3, H336 NDA 662-2 50100 mg/m' OSHA HCS 2012: Flam. Liq.2; Eye Irrit.2A,STOT SE 3: Resp. Irrit.&Narc.; Repr.2 Ingestion/Oral-Rat CAS:1330-20-7 LD50•4300 mg/kg EU DSDIDPD: Annex I: R10,Xn; R20/21,Xi; R38 EC EU CLP: Annex VI: Flam. Liq. 3, H226;Acute Tox. Xylene Number:215- < 1% Inhalation-Rat mg/kg 5000 ppm 4 Hour(s)• 4*, H312;Acute Tox.4*, H332; Skin Irrit.2, H315 NDA OSHA HCS 2012: Acute Tox 4(Skin);Eye Irrit. 535-7 Skin-Rabbit LD50• 2A;Skin Irrit.2; Repr.2 >1700 mg/kg CAS:100-42-5 Ingestion/Oral-Rat EU DSD/DPD: Annex I: R10 Xn; R20 Xi; R36/38 EC LD50•2650 mg/kg EU CLP: Annex VI: Flam. Liq. 3, H226;Acute Tox. Styrene Number:202- <1 o�0 Inhalation-Rat LC50• 4*, H332; Eye Irrit.2, H319;Skin Irrit.2, H315 NDA 851-5 2770 ppm 4 Hour(s) OSHA HCS 2012: Eye Irrit.2;Acute Tox.4;Carc. 2 CAS:1309-48-4 EU DSD/DPD: Self Classified:Xi, R36/37 EC EU CLP: Self Classified: Eye Irrit.2, H319;STOT Magnesium oxide Number:215- <1% NDA SE 3, H335 NDA 171-9 OSHA HCS 2012: Eye Irrit.2; STOT SE 3: Resp. Irrit. CAS:1314-13-2 EU DSD/DPD: Annex I: N; R50-53 Zinc oxide EC <0.3% NDA EU CLP: Annex VI:Aquatic Acute 1, H400; NDA Number:215- Aquatic Chronic 1, H410 222-5 OSHA HCS 2012: Not Classified Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 5 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive See Section 11 for Toxicological Information. Section 4 - First Aid Measures 4.1 Description of first aid measures Inhalation . IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Administer oxygen if breathing is difficult. Give artificial respiration if victim is not breathing. Get medical attention immediately if symptoms occur. Skin a In case of contact with substance, immediately flush skin with running water for at least 20 minutes. Remove and isolate contaminated clothing and shoes. If skin irritation occurs: Get medical advice/attention. Eye a In case of contact with substance, immediately flush eyes with running water for at least 20 minutes. If eye irritation persists: Get medical advice/attention. Ingestion . If swallowed, rinse mouth with water(only if the person is conscious) Do NOT induce vomiting. Do not give anything by mouth to an unconscious person. Get medical attention immediately if symptoms occur. 4.2 Most important symptoms and effects, both acute and delayed e Refer to Section 11 -Toxicological Information. 4.3 Indication of any immediate medical attention and special treatment needed Notes to Physician . All treatments should be based on observed signs and symptoms of distress in the patient. Consideration should be given to the possibility that overexposure to materials other than this product may have occurred. Section 5-- Firefighting:Measures 5.1 Extinguishing media Suitable Extinguishing Media e CAUTION: For mixtures containing a high percentage of an alcohol or polar solvent, alcohol-resistant foam may be more effective. LARGE FIRES: Water spray, fog or alcohol-resistant foam. SMALL FIRES: Dry chemical, CO2, water spray or alcohol-resistant foam. Unsuitable Extinguishing • Do not use a direct stream of water. Media 5.2 Special hazards arising from the substance or mixture Unusual Fire and Explosion . Containers may explode when heated. Hazards Vapor explosion hazard indoors, outdoors or in sewers. HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Many liquids are lighter than water. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Runoff to sewer may create fire or explosion hazard. Those substances designated with a "P" may polymerize explosively when heated or involved in a fire. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Hazardous Combustion • Oxides of carbon, oxides of nitrogen, hydrochloric acid. Products 5.3 Advice for firefighters • Structural firefighters' protective clothing will only provide limited protection. Wear positive pressure self-contained breathing apparatus (SCBA). Move containers from fire area if you can do it without risk. LARGE FIRES: Cool containers with flooding quantities of water until well after fire is out. Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 6 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive Section 6'-Accidental Release,Measures' 6.1 Personal precautions, protective equipment and emergency procedures Personal Precautions . CAUTION: Victim may be a source of contamination. Do not touch or walk through spilled material. Emergency Procedures e As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions. If tank, rail car or tank truck'is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet) ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Keep unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate closed spaces before entering. 6.2 Environmental precautions e Prevent entry into waterways, sewers, basements or confined areas. 6.3 Methods and material for containment and cleaning up Containment/Clean-up . Stop leak if you can do it without risk. Measures Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material. A vapor suppressing foam may be used to reduce vapors. All equipment used when handling the product must be grounded. LARGE SPILLS: Dike far ahead of liquid spill for later disposal. LARGE SPILLS: Water spray may reduce vapor; but may not prevent ignition in closed spaces. 6.4 Reference to other sections • Refer to Section 8 - Exposure Controls/Personal Protection and Section 13 - Disposal Considerations. Section 7 - Handling and Storage:_ . 7.1 Precautions for safe handling Handling . Do not use in areas without adequate ventilation. Handle and open container with care. Use good safety and industrial hygiene practices. 7.2 Conditions for safe storage, including any incompatibilities Storage . Keep away from fire. Store in a well-ventilated place. Keep container tightly closed. 7.3 Specific end use(s) Refer to Section 1.2 - Relevant identified uses. Section 8 - Ex ,osure.Controls/Pe p rsonal Protection. 8.1 Control parameters Exposure Limits/Guidelines .. Result ACGIH Canada Ontario Canada Quebec China Europe STELs Not established Not established Not established 100 mg/m3 STEL 100 ppm STEL;384 Toluene mg/m3 STEL (108-88-3) 50 ppm TWAEV; 188 50 ppm TWA; 192 TWAs 20 ppm TWA 20 ppm TWA mg/m3 TWAEV 50 mg/m3 TWA mg/m3 TWA Exposure Limits/Guidelines (Con't: Result Germany DFG Germany TRGS NIOSH OSHA Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 7 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive Ceilings 200 ppm Peak;760 Not established Not established 300 ppm Ceiling mg/m3 Peak 50 ppm TWA AGW (The risk of damage to the embryo or fetus can be excluded when AGW and BGW values are observed, TWAs Not established exposure factor 4); 100 ppm TWA;375 200 ppm TWA Toluene 190 mg/m3 TWA AGW mg/m3 TWA (108-88-3) (The risk of damage to the embryo or fetus can be excluded when AGW and BGW values are observed, exposure factor 4) STELs Not established Not established 150 ppm STEL;560 Not established mg/m3 STEL MAKs 50 ppm TWA MAK; 190 Not established Not established Not established mg/m3 TWA MAK Exposure Control Notations China ,Toluene(108-88-3):Skin: (Skin notation) ,Styrene(100-42-5):Skin: (Skin notation) Canada Quebec ,Toluene(108-88-3):Skin: (Skin designation) *Styrene(100-42-5):Carcinogens: (C3 carcinogen-effect detected in animals) Skin: (Skin designation) ACGIH *Toluene(108-88-3):Carcinogens: (A4-Not Classifiable as a Human Carcinogen) ,Acetone(67-64-1):Carcinogens: (A4-Not Classifiable as a Human Carcinogen) •Xylene(1330-20-7):Carcinogens: (A4-Not Classifiable as a Human Carcinogen) *Magnesium oxide(1309-48-4):Carcinogens: (A4-Not Classifiable as a Human Carcinogen) *Styrene(100-42-5):Carcinogens: (A4-Not Classifiable as a Human Carcinogen) Germany TRGS ,Toluene(108-88-3):Skin:(skin notation) •Xylene(1330-20-7):Skin: (skin notation(all isomers)) Germany DFG *Toluene(108-88-3): Pregnancy: (no risk to embryo/fetus if exposure limits adhered to)I Skin: (skin notation) *Acetone(67-64-1): Pregnancy: (classification not yet possible) •Xylene(1330-20-7): Pregnancy: (classification not yet possible(all isomers))I Skin: (skin notation(all isomers)) ,Magnesium oxide(1309-48-4): Pregnancy: (no risk to embryo/fetus if exposure limits adhered to(respirable fraction);inhalable fraction) *Styrene(100-42-5):Carcinogens: (Category 5(low carcinogenic potency))I Pregnancy: (no risk to embryo/fetus if exposure limits adhered to) Exposure Limits Supplemental ACGIH *Toluene(108-88-3): BEIs:(0.02 mg/L Medium: blood Time: prior to last shift of workweek Parameter:Toluene;0.03 mg/L Medium: urine Time:end of shift Parameter:Toluene;0.3 mg/g creatinine Medium: urine Time:end of shift Parameter:o-Cresol with hydrolysis(background))I TLV Basis- Critical Effects: (female reproductive;pregnancy loss;visual impairment) ,Acetone(67-64-1): BEIs:(50 mg/L Medium:urine Time:end of shift Parameter:Acetone(nonspecific))I TLV Basis-Critical Effects: (CNS impairment;eye and upper respiratory tract irritation;hematologic effects)I Notice of Intended Changes(TLVs): (200 ppm TWA;500 ppm STEL; BEI;TLV basis:CNS impairment, upper respiratory tract irritation) •Xylene(1330-20-7): BEIs: (1.5 g/g creatinine Medium: urine Time:end of shift Parameter: Methylhippuric acids)I TLV Basis-Critical Effects: (CNS impairment;eye and upper respiratory tract irritation) *Zinc oxide(1314-13-2):TLV Basis-Critical Effects: (metal fume fever) ,Styrene(100-42-5):BEIs:(400 mg/g creatinine Medium: urine Time:end of shift Parameter:Mandelic acid plus phenylglyoxylic acid(nonspecific); Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 8 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive 0.2 mg/L Medium:venous blood Time:end of shift Parameter:Styrene(semi-quantitative))I TLV Basis-Critical Effects: (CNS impairment; peripheral neuropathy; upper respiratory tract irritation) 8.2 Exposure controls Engineering • This adhesive is designed to be used outdoors, in roofing applications. Good general Measures/Controls ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Personal Protective Equipment Respiratory • Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH or European Standard EN 149 approved respirator if exposure limits are exceeded or symptoms are experienced. Eye/Face . Wear chemical splash safety goggles. Skin/Body • Wear appropriate chemical resistant gloves. Environmental Exposure • In case of spills, keep product clear of sewers, waterways or land areas. Dispose of Controls waste product in accordance with national and local laws and regulations. Section 9.- Physical and Chemical Properties 9.1 Information on Physical and Chemical Properties Material Description Physical Form Liquid Appearance/Description Yellow amber liquid with strong aromatic odor. Color Yellow amber. Odor Aromatic Odor Threshold Data lacking General Properties Boiling Point 55 to 142 F(12.7778 to 61.1111 C) Melting Point Data lacking Decomposition Temperature Data lacking pH Data lacking Specific Gravity/Relative Density 0.844 Water=l Water Solubility Insoluble Viscosity Not relevant Explosive Properties Explosion hazard. Oxidizing Properties: Static hazard. Volatility Vapor Pressure 9.to 185 mmHg(torr)@ 68 F(20 Vapor Density >3 Air=1 Evaporation Rate 1.9 to 9.5 n-Butyl Acetate= 1 VOC(Vol.) 633 g/L Volatiles(Vol.) 76.4% Flammability Flash Point -18 C(-0.4 F) UEL 7.5% LEL 1.1 % Autoignition Data lacking Flammability(solid,gas) Not relevant. Environmental Octanol/Water Partition coefficient Data lacking 9.2 Other Information • No additional physical and chemical parameters noted. Section 10:-Stability and Reactivity 10.1 Reactivity • No dangerous reaction known under conditions of normal use. Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 9 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive 10.2 Chemical stability e Stable under normal temperatures and pressures. 10.3 Possibility of hazardous reactions a Hazardous polymerization will not occur. 10.4 Conditions to avoid a Avoid flames, sparks, and other sources of ignition. Avoid contact with combustible materials. Avoid contact with incompatible materials. 10.5 Incompatible materials a Acids, bases, combustible materials, oxidizing materials. 10.6 Hazardous decomposition products Thermal decomposition could produce CO, CO2, and Oxides of Nitrogen. :Section 11,-Toxicological Information 11.1 Information on toxicological effects Components Acute Toxicity: Ingestion/Oral-Rat LD50•636 mg/kg; Inhalation-Rat LC50-49 g/m'4 Hour(s);Skin-Rabbit LD50• 14100 Toluene pUkg; (34%TO 108- Irritation: Eye-Rabbit• 100 mg 30 Second(s)-Rinse•Mild irritation;Skin-Rabbit•435 mg•Mild irritation; 44%) 88-3 Reproductive: Inhalation-Rat TCLo• 1500 ppm(7-20D preg);Reproductive Effects:Specific Developmental Abnormalities:Central nervous system;Reproductive Effects:Effects on Newbom:Growth statistics(e.g., reduced weight gain);Reproductive Effects:Effects on Newborn:Biochem ica I and metabolic GHS Properties Classification Acute toxicity EU/CLP.Classification criteria not met OSHA HCS 2012.Acute Toxicity-Oral 4 EU/CLP.Classification criteria not met Aspiration Hazard OSHA HCS 2012.Classification criteria not met Carcinogenicity EU/CLP.Classification criteria not met OSHA HCS 2012.Carcinogenicity 2 EU/CLP.Classification criteria not met Germ Cell Mutagenicity OSHA HCS 2012.Classification criteria not met EU/CLP.Skin Irritation 2 Skin corrosion/Irritation OSHA HCS 2012.Skin Irritation 2 EU/CLP.Classification criteria not met Skin sensitization OSHA HCS 2012.Classification criteria not met EU/CLP.Specific Target Organ Toxicity Repeated Exposure 2 STOT-RE OSHA HCS 2012.Specific Target Organ Toxicity Repeated Exposure 2 EU/CLP.Specific Target Organ Toxicity Single Exposure 3: Narcotic Effects STOT-SE OSHA HCS 2012.Specific Target Organ Toxicity Single Exposure 3: Narcotic Effects Toxicity for Reproduction EU/CLP.H361 d-Suspected of damaging the unborn child;Toxic to Reproduction 2 OSHA HCS 2012.Toxic to Reproduction 2 EU/CLP.Classification criteria not met Respiratory sensitization OSHA HCS 2012.Classification criteria not met Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 10 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive EU/CLP.Eye Irritation 2 Serious eye damage/Irritation OSHA HCS 2012.Eye Irritation 2A Route(s) of entry/exposure • Inhalation, Skin, Eye, Ingestion/Oral Potential Health Effects Inhalation Acute (Immediate) • May be harmful. May affect the central nervous system. Symptoms may include dizziness, drowsiness, lethargy, coma and death. Chronic (Delayed) • Repeated and prolonged exposure may cause Central Nervous System (CNS) effects. Skin Acute (Immediate) • Causes skin irritation. Chronic (Delayed) • No data available. Eye Acute (Immediate) • Causes serious eye irritation. Chronic (Delayed) • No data available. Ingestion Acute (Immediate) • May be harmful. Chronic (Delayed) • No data available. Carcinogenic Effects CAS IARC NTP Toluene 108-88-3 1 Group 3-Not Classifiable Evidence of Carcinogenicity Reproductive Effects • Repeated and prolonged exposure may cause reproductive effects. Section 12 - Ecological Information 12.1 Toxicity UltraPly Bonding Adhesive Dosage Species Duration Results Exposure Conditions Comments 6.8 mg/L Water Flea: Daphnia magna 48 Hour(s) EC50 NDA Toluene 28 mg/L Water Flea: Daphnia magna 48 Hour(s) NOEC NDA Toluene 0.00025 Fish: Fathead Minnow 96 Hour(s) LC50 NDA Hexane mg/L • This material may be toxic to aquatic organisms and cause long-term adverse effects in the aquatic environment. 12.2 Persistence and degradability • No information available for the product. 12.3 Bioaccumulative potential • No information available for the product. 12.4 Mobility in Soil • No information available for the product. 12.5 Results of PBT and vPvB assessment • PBT and vPvB assessment has not been carried out. 12.6 Other adverse effects • No studies have been found. Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 11 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive Section 13 - Disposal Considerations 13.1 Waste treatment methods Product waste . Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. Packaging waste . Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. Section;14 -.Transport Information 14.1 UN 14.2 UN proper 14.3 Transport hazard 14.4 Packing 14.5 Environmental number shipping name class(es) group hazards DOT UN1133 I Adhesives 3 II NDA TDG UN1133 ( ADHESIVES 3 II NDA IMO/IMDG UN1133 ADHESIVES 3 II NDA ADN UN1133 ADHESIVES 3 ! II NDA ADRIRID UN1133 ADHESIVES 3 II NDA IATA/ICAO. UN1133 Adhesives 3 II NDA 14.6 Special precautions for . None known. user 14.7 Transport in bulk . Not relevant. according to Annex Ii of MARPOL 73/78 and the IBC Code 14.8 Other information DOT . Toluene has a reportable quantity of 1000 Ibs (454 kg) as listed in Appendix A to 49 CFR 172.101. Hexane has a reportable quantity of 5000 Ibs (2270 kg) as listed in Appendix A to 49 CFR 172.101. Cyclohexane has a reportable quantity of 1000lbs (454kg) as listed in Appendix A to 49 CFR 172.101. Section 15 - Regulatory Information _ 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture SARA Hazard Classifications . Acute, Chronic, Fire state Right To Know:, Component CAS MA NJ PA Toluene 108-88-3 1 Yes Yes Yes Inventory Component CAS Canada DSL Canada NDSL China EU EINECS EU ELNICS Toluene 108-88-3 1 Yes No Yes Yes No InventoryCon't: Component CAS Japan ENCS Korea KECL TSCA Toluene 108-88-3 Yes Yes Yes Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 12 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive Australia Labor Australia-Work Health and Safety Regulations-Hazardous Substances Requiring Health Monitoring • Toluene 108-88-3 Not Listed Australia-High Volume Industrial Chemicals List • Toluene 108-88-3 Australia-List of Designated Hazardous Substances-Classification F,Xn,Xi Repr.Cat.3 R11, R63, • Toluene 108-88-3 R48/20, R65, R38, R67 Environment Australia-National Pollutant Inventory(NPI)Substance List • Toluene 108-88-3 10 tonne/yr Threshold category 1 Australia-Ozone Protection Act-Scheduled Substances • Toluene 108-88-3 Not Listed Australia-Priority Existing Chemical Program • Toluene 108-88-3 Candidate chemical Bulgaria Environment Bulgaria-Air Quality-Maximum Admissible Hazardous Contaminant Levels-24 Hour • Toluene 108-88-3 0.25 mg/m3 MAHCL Canada Labor Canada-WHMIS-Classifications of Substances • Toluene 108-88-3 B2, D2A, D2B Canada-WHMIS-Ingredient Disclosure List • Toluene 108-88-3 1 % Environment Canada-CEPA-Priority Substances List Priority Substance List 1 • Toluene 108-88-3 (substance not considered toxic) Europe Other EU-CLP(1272/2008)-Annex VI-Table 3.2-Classification • Toluene 108-88-3 F; R11 Xi; R38 Xn; R48/20-65 Repr.Cat.3;R63 R67 EU-CLP(1272/2008)-Annex VI-Table 3.2-Concentration Limits • Toluene 108-88-3 Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Labelling Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 13 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive • Toluene 108-88-3 F Xn R:11-38-48/20-63-65-67 S:(2)-36/37-46-62 EU-CLP(1272/2008)-Annex VI-Table 3.2-Notes-Substances and Preparations • Toluene 108-88-3 Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Safety Phrases • Toluene 108-88-3 S:(2)-36/37-46-62 Mexico Other Mexico-Hazard Classifications • Toluene 108-88-3 Hazard Class=3 PG=II UN1294 Mexico-Regulated Substances • Toluene 108-88-3 UN1294 United States Labor U.S.-OSHA-Process Safety Management-Highly Hazardous Chemicals • Toluene 108-88-3 Not Listed U.S.-OSHA-Specifically Regulated Chemicals • Toluene 108-88-3 Not Listed Environment U.S.-CAA(Clean Air Act)-1990 Hazardous Air Pollutants • Toluene 108-88-3 U.S.-CERCLA/SARA-Hazardous Substances and their Reportable Quantities 1000 lb final RQ;454 kg final • Toluene 108-88-3 RQ U.S.-CERCLA/SARA-Section 302 Extremely Hazardous Substances EPCRA RQs • Toluene 108-88-3 Not Listed U.S.-CERCLA/SARA-Section 302 Extremely Hazardous Substances TPQs • Toluene 108-88-3 Not Listed U.S.-CERCLA/SARA-Section 313-Emission Reporting • Toluene 108-88-3 1.0%de minimis concentration U.S.-CERCLA/SARA-Section 313-PBT Chemical Listing • Toluene 108-88-3 Not Listed U.S.-RCRA(Resource Conservation&Recovery Act)-Hazardous Constituents-Appendix VIII to 40 CFR 261 • Toluene 108-88-3 waste number U220 U.S.-RCRA(Resource Conservation&Recovery Act)-List for Hazardous Constituents • Toluene 108-88-3 United States - California Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 14 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive Environment U.S.-California-Proposition 65-Carcinogens List - Toluene 108-88-3 Not Listed U.S.-California-Proposition 65-Developmental Toxicity • Toluene 108-88-3 developmental toxicity, initial date 1/1/91 U.S.-California-Proposition 65-Reproductive Toxicity-Female • Toluene 108-88-3 female reproductive toxicity, initial date 8/7/09 U.S.-California-Proposition 65-Reproductive Toxicity-Male - Toluene 108-88-3 Not Listed United States - Pennsylvania Labor U.S.-Pennsylvania-RTK(Right to Know)-Environmental Hazard List - Toluene 108-88-3 U.S.-Pennsylvania-RTK(Right to Know)-Special Hazardous Substances - Toluene 108-88-3 Not Listed United States - Rhode Island Labor U.S.-Rhode Island-Hazardous Substance List • Toluene 108-88-3 Toxic(skin); Flammable(skin) 15.2 Chemical Safety Assessment No Chemical Safety Assessment has been carried out. Section.16 - Other Information Relevant Phrases (code 8r full text) H226 - Flammable liquid and vapour H312 - Harmful in contact with skin H332 - Harmful if inhaled H335 - May cause respiratory irritation H340 - May cause genetic defects. H350 - May cause cancer. H400-Very toxic to aquatic life R10 - Flammable. R20 - Harmful by inhalation. R36 - Irritating to eyes. R36/37 - Irritating to eyes and respiratory system. R36/38 - Irritating to eyes and skin. R45 - May cause cancer. R46 - May cause heritable genetic damage. R50 - Very toxic to aquatic organisms. R66 - Repeated exposure may cause skin dryness or cracking. Last Revision Date . 30/December/2014 Preparation Date . 07/February/2013 Disclaimer/Statement of . The information contained herein is based on data considered accurate which has Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 15 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 UltraPly Bonding Adhesive Liability been obtained from other companies and organizations. However, no warranty or representation is expressed or implied that the information, is accurate, complete or representative. Firestone Building Products Company, LLC assumes no responsibility for injury to the buyer, the buyer's employees, or any third persons, if reasonable safety procedures are not followed. Additionally, Firestone Building Products Company assumes no responsibility for injury to buyer, the buyer's employees, or any third persons caused by abnormal use of this material, even if reasonable safety procedures are followed. Key to abbreviations NDA=No data available Preparation Date: 07/February/2013 Format:EU CLP/REACH Language:English(US) Revision Date: 30/December/2014 Page 16 of 16 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+�GL(Flat and Tapered),ISO 95+*m CAN Safety Data Sheet Firestone Building Products Company Section.1: Identification of the.Substance/Mixture and of the Company/Undertaking 1.1 Product identifier Product Name • ISO 95+Tm GL (Flat and Tapered), ISO 95+TM CAN 1.2 Relevant identified uses of the substance or mixture and uses advised against Relevant identified use(s) . Construction 1.3 Details of the supplier of the safety data sheet Manufacturer . Firestone Building Products Company 250 West 96th Street Indianapolis, IN 46260 United States firestonemsds(&bfdp.com Telephone (General) . 800-428-4442 1.4 Emergency telephone number Manufacturer . (800) 424-9300 - CHEMTREC Manufacturer . (703) 527-3887 - CHEMTREC - International Section.2: Hazards.Identification EU/EEC According to Regulation (EC) No 1272/2008 (CLP)/REACH 1907/2006 [amended by 45312010] According to EU Directive 67/548/EEC (DSD) or 1999/45/EC (DPD) 2.1 Classification of the substance or mixture CLP . Not classified DSD/DPD . Not classified 2.2 Label Elements CLP Hazard statements • No label element(s) required DSD/DPD Risk phrases . No label element(s) required 2.3 Other Hazards CLP . According to Regulation (EC) No. 1272/2008 (CLP) this material is not considered hazardous. DSD/DPD . According to European Directive 1999/45/EC this preparation is not considered dangerous. United States (US) According to OSHA 29 CFR 1910.1200 HCS Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 1 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+Tm GL(Flat and Tapered),ISO 95+T CAN 2.1 Classification of the substance or mixture OSHA HCS 2012 . Not classified 2.2 Label elements OSHA HCS 2012 Hazard statements . No label elements(s) required 2.3 Other hazards OSHA HCS 2012 , This product is not considered hazardous under the U.S. OSHA 29 CFR 1910.1200 Hazard Communication Standard. Canada According to WHMIS 2.1 Classification of the substance or mixture WHMIS . Not classified 2.2 Label elements WHMIS . No label element(s) required 2.3 Other hazards WHMIS . In Canada, the product mentioned above is not considered hazardous under the Workplace Hazardous Materials Information System (WHMIS). Section 3 - Composition/Information on Ingredients 3.1 Substances Material does not meet the criteria of a substance in accordance with Regulation (EC) No 1272/2008. 3.2 Mixtures Composition Chemical Name Identifiers % LD501LC50 Classifications According to Comments Regulation/Directive CAS:65997-17- Glass,oxide, 3 EU DSD/DPD: Not Classified chemicals EC <11% NDA EU CLP: Not Classified NDA Number:266- OSHA HCS 2012: Not Classified 046-0 EU DSD/DPD:Annex I: F+; R12 N; R51-53 Xn; R65 R66 R67 CAS:78-78-4 Inhalation-Rat LC50 EU CLP: Annex VI: Flam. Liq. 1, H224;Asp. 2-Methylbutane EC 4.5%oTO 280000 mg/m'4 Hour Tox. 1, H304; STOT SE 3, H336;Aquatic NDA /o Number:201- 9.9 Chronic 2, H411; EUH066 142-8 (s) OSHA HCS 2012: Flam Liq 1; Eye Irrit.2A; Skin Irrit.2;STOT SE 3: Resp. Irrit.&Narc., Asp.Tox. 1 Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 2 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM+GL(Flat and Tapered),ISO 95+Tm CAN EU DSD/DPD:Annex I: F+; R12 N; R51-53 Xn; CAS:109-66-0 Inhalation-Rat LC50• R65 R66 R67 EC 0.05% 364 g/m'4 Hour(s) EU CLP: Annex VI: Flam. Liq.2, H225;Asp. Pentane Tox. 1, H304;STOT SE 3: Narc., H336;Aquatic NDA Number:203- TO 5.5% Ingestion/Oral-Rat 692-4 LD50•>2000 mg/kg Chronic 2, H411; EUH066 OSHA HCS 2012: Flam. Liq. 1;Asp.Tox. 1. Eye Irrit.2, Skin Irrit.2,STOT SE 3: Narc. CAS:13674-84- 2-Propanol, 1- 5 EU DSD/DPD: Self Classified:Xn, R22 chloro-,2,2',2"- EC <5% Ingestion/Oral-Rat EU CLP: Self Classified:Acute Tox.4, H302 NDA phosphate Number:237- LD50• 1500 mg/kg OSHA HCS 2012: Acute Tox.4(Oral) 158-7 See Section 11 for Toxicological Information. See Section 16 for full text of H-statements and R-phrases. Section 4 - First Aid Measures :. 4.1 Description of first aid measures Inhalation , Move victim to fresh air. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Skin , In case of contact with substance, immediately flush skin with running water for at least 20 minutes. Eye , In case of contact with substance, immediately flush eyes with running water for at least 20 minutes. Ingestion , Rinse mouth. Do not give anything by mouth to an unconscious person. 4.2 Most important symptoms and effects, both acute and delayed , Refer to Section 11 -Toxicological Information. 4.3 Indication of any immediate medical attention and special treatment needed Notes to Physician , No specific actions or treatments recommended related to exposure to this material. Section 5 -Firefighting Measures 5.1 Extinguishing media Suitable Extinguishing Media , LARGE FIRE: Water spray, fog or regular foam. SMALL FIRES: Dry chemical, CO2, water spray or regular foam. Unsuitable Extinguishing , No data available. Media 5.2 Special hazards arising from the substance or mixture Unusual Fire and Explosion , Burning of this product will produce thick black smoke. Hazards Toxic fumes and vapors may be produced. Avoid generating dust; fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source is a potential dust explosion hazard. Isopentane and n-pentane, highly flammable materials, may be present within this product. Hazardous Combustion , Carbon dioxide and carbon monoxide, phosphorus oxides, and phosphoric acid. Products 5.3 Advice for firefighters Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing will only provide limited protection. Fire fighters should wear complete protective clothing including self-contained breathing apparatus. Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 3 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM GL(Flat and Tapered),ISO 95+TM+CAN Section 6 -Accidental Release Measures 6.1 Personal precautions, protective equipment and emergency procedures Personal Precautions . Not applicable. Emergency Procedures . Not applicable. 6.2 Environmental precautions . No special precautions necessary. 6.3 Methods and material for containment and cleaning up Containment/Clean-up . Avoid generating dust. Measures Pick up large pieces. Sweep and scoop up material and put into a suitable container for disposal as a non-hazardous waste. 6.4 Reference to other sections . Refer to Section 8 - Exposure Controls/Personal Protection and Section 13 - Disposal Considerations. Section 7 - Handling.and Storage 7.1 Precautions for safe handling Handling . Use only in well ventilated areas. Wear appropriate personal protective equipment. Protect against dust that may be generated by reprocessing, altering or applying this product. Minimize dust generation and accumulation. Routine housekeeping should be instituted to ensure that dusts do not accumulate on surfaces. Wash thoroughly with soap and water after handling and before eating, drinking, or using tobacco. 7.2 Conditions for safe storage, including any incompatibilities Storage . Keep away from heat, sparks and flame. Store in a cool, dry place. 7.3 Specific end use(s) . Refer to Section 1.2 - Relevant identified uses. Section 8 - Exposure Controls/Personal Protection 8.1 Control parameters Exposure:Limits/Guidelines Result ACGIH Canada Alberta Canada British Canada NewColumbia Brunswick Canada Ontario 600 ppm TWA(listed 600 ppm TWA(listed 600 ppm TWA; 1770 600 ppm TWA; 1770 Pentane TWAs under Pentane,all mg/m3 TWA under Pentane, all mg/m3 TWA 600 ppm TWA (109-66-0) isomers) isomers) STELs Not established Not established Not established 750 ppm STEL;2210 mg/m3 STEL Not established 600 ppm TWA(listed 600 ppm TWA(listed 600 ppm TWA(listed (78-78-4) mg/m3 TWA ylbutane TWAs under Pentane, all 600 ppm TWA; 1770 under Pentane,all Not established under Pentane,all 78-78 isomers) isomers) isomers) 1 fibre/cm3 TWA 1 fiber/cm3 TWA 1 fibre/cm3 TWA (fibres>5 pm in (respirable fibers: (fibres>5 pm,with length and an aspect length>5 pm,aspect an aspect ratio of ratio>=3:1 as ratio>=3:1,as —3:1, as determined determined by the Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 4 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM GL(Flat and Tapered),ISO 95+TM CAN determined by the by the membrane membrane filter 1 fibre/cm3 TWA membrane filter filter method at 400- method at 400-450 Glass,oxide, method at 400-45OX 1 fibre/cm3 TWA 450 times (fibres>5 3 p with a times magnification chemicals as Glass TWAs magnification 4-mm magnification 4 mm diameter<3 pm, g I g ( aspect ratio>5:1) (4-mm objective), wool fiber objective], using as Glass wool fiber objective), using using phase-contrast phase-contrast phase-contrast as Glass wool fiber illumination, illumination, listed illumination,listed respirable, listed under Synthetic under Synthetic under Synthetic vitreous fibers) vitreous fibres) Vitreous Fibres(Man Made Mineral Fibres)) as Glass wool fiber as Glass wool fiber as Glass wool fiber Ex osure'Limits/Guideliries Cont. Result Canada Quebec Canada Yukon Europe NIOSH OSHA TWAs 120 ppm TWAEV; 600 ppm TWA; 1800 1000 ppm TWA;3000 120 ppm TWA;350 1000 ppm TWA;2950 350 mg/m3 TWAEV mg/m3 TWA mg/m3 TWA mg/m3 TWA mg/m3 TWA Pentane STELs Not established 750 ppm STEL;2250 Not established Not established Not established (109-66-0) mg/m3 STEL 610 ppm Ceiling(15 Ceilings Not established Not established Not established min); 1800 mg/m3 Not established Ceiling(15 min) 2-Methylbutane TWAs Not established Not established 1000 ppm TWA;3000 Not established Not established (78-78-4) mg/m3 TWA 2 fibre/cm3 TWAEV 3 fiber/cm3 TWA (respirable, listed 30 mppcf TWA; 10 (fibers—3.5 pm in Glass,oxide, under Fibres- mg/m3 TWA diameter and>=10 chemicals as Glass TWAs Artificial Vitreous (respirable mass) Not established pm in length);5 Not established wool fiber Mineral Fibres) mg/m3 TWA(total) as Glass wool fiber as Glass wool fiber as Glass wool fiber 8.2 Exposure controls Engineering . No special controls are expected to be needed. Measures/Controls Personal Protective Equipment Respiratory . Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH or European Standard EN 149 approved respirator if exposure limits are exceeded or symptoms are experienced. Eye/Face . Wear safety goggles. Hands . Wear appropriate gloves. Skin/Body . Wear long sleeves and/or protective coveralls if determined to be needed by the end- user. Environmental Exposure . Follow best practice for site management and disposal of waste. Controls Key to abbreviations ACGIH=American Conference of Governmental Industrial Hygiene STEL =Short Term Exposure Limits are based on 15-minute exposures NIOSH=National Institute of Occupational Safety and Health TWAEV=Time-Weighted Average Exposure Value OSHA =Occupational Safety and Health Administration TWA =Time-Weighted Averages are based on Sh/day,40h/week exposures Section 9 - Physical and Chemical Properties 9.1 Information on Physical and Chemical Properties Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 5 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+T GL(Flat and Tapered),ISO 95+w CAN Material Description Physical Form Solid Appearance/Description White rigid cellular sheets with no odor. Color White Odor Odorless Odor Threshold Data lacking General Properties Boiling Point Data lacking Melting Point Data lacking Decomposition Temperature Data lacking pH Data lacking Specific Gravity/Relative Density Data lacking Water Solubility Insoluble Viscosity Data lacking Explosive Properties Not explosive. Oxidizing Properties: Not an oxidizer. Volatility Vapor Pressure Data lacking Vapor Density Data lacking Evaporation Rate Data lacking Flammability Flash Point Data lacking UEL Data lacking LEL Data lacking Autoignition Data lacking Flammability(solid,gas) Not flammable. Environmental Octanol/Water Partition coefficient jDatalacking 9.2 Other Information . No additional physical and chemical parameters noted. Section -10: Stability and:Reactivity, 10.1 Reactivity . No dangerous reaction known under conditions of normal use. 10.2 Chemical stability . Stable under normal temperatures and pressures. 10.3 Possibility of hazardous reactions . Hazardous polymerization not indicated. 10.4 Conditions to avoid . No data available. 10.5 Incompatible materials . No data available. 10.6 Hazardous decomposition products . No data available. Section 11 -Toxicological Information 11.1 Information on toxicological effects Component Name CAS Data Pentane(0.05%TO 5.5%) 109-66-0 Acute Toxicity: orl-rat LD50:>2000 mg/kg;ihl-rat LC50:364 gm/m3/4H 2-Methylbutane(4.5%TO 9.9%) 78-78-4 Acute Toxicity: ihl-rat LC50:280000 mg/m3/4H Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 6 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM GL(Flat and Tapered),ISO 95+T CAN 2-Propanol, 1-chloro-,2,2',2"-phosphate(<5%) 13674-84-5 Acute Toxicity: orl-rat LD50:1500 mg/kg GHS Properties Classification EU/CLP-Classification criteria not met Acute toxicity OSHA HCS 2012.Classification criteria not met Aspiration Hazard EU/CLP-Classification criteria not met OSHA HCS 2012.Classification criteria not met EU/CLP.Classification criteria not met Carcinogenicity OSHA HCS 2012.Classification criteria not met EU/CLP-Classification criteria not met Germ Cell Mutagenicity OSHA HCS 2012.Classification criteria not met Skin corrosion/Irritation EU/CLP-Classification criteria not met OSHA HCS 2012.Classification criteria not met EU/CLP.Classification criteria not met Skin sensitization OSHA HCS 2012.Classification criteria not met STOT-RE EU/CLP-Classification criteria not met OSHA HCS 2012.Classification criteria not met EU/CLP-Classification criteria not met STOT-SE OSHA HCS 2012.Classification criteria not met EU/CLP-Classification criteria not met Toxicity for Reproduction OSHA HCS 2012.Classification criteria not met EU/CLP.Classification criteria not met Respiratory sensitization OSHA HCS 2012-Classification criteria not met EU/CLP-Classification criteria not met Serious eye damage/Irritation OSHA HCS 2012.Classification criteria not met Route(s) of entry/exposure . Inhalation, Skin, Eye, Ingestion Medical Conditions . Disorders of the lungs. Aggravated by Exposure Potential Health Effects Inhalation Acute (Immediate) . Exposure to dust may cause irritation. Processes such as cutting, grinding, crushing, or impact may result in generation of excessive amounts of airborne dusts in the workplace. Nuisance dust may affect the lungs but reactions are typically reversible. Chronic (Delayed) . No data available Skin Acute (Immediate) . Exposure to dust may cause mechanical irritation. Chronic (Delayed) . No data available. Eye Acute (Immediate) . Exposure to dust may cause mechanical irritation. Excessive concentrations of nuisance dust in the workplace may reduce visibility and may cause unpleasant deposits in eyes. Chronic (Delayed) . No data available. Ingestion Acute (Immediate) . Excessive concentrations of nuisance dust in the workplace may cause mechanical irritation to mucous membranes. Chronic (Delayed) . No data available. Key to abbreviations Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 7 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM GL(Flat and Tapered),ISO 95+TM CAN LC=Lethal Concentration LD=Lethal Dose Section 12 - Ecological'Information 12.1 Toxicity . Material data lacking. 12.2 Persistence and degradability . Material data lacking. 12.3 Bioaccumulative potential . Material data lacking. 12.4 Mobility in Soil . Material data lacking. 12.5 Results of PBT and vPvB assessment . No PBT and vPvB assessment has been conducted. 12.6 Other adverse effects . No studies have been found. Section-13 - Disposal Considerations . 13.1 Waste treatment methods Product waste . Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. Packaging waste . Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. Section 14 -Transport.Information 14.1 UN 14.2 UN proper 14.3 Transport hazard 14.4 Packing 14.5 Environmental number shipping name class(es) group hazards DOT NDA Not regulated NDA NDA NDA TDG NDA Not regulated NDA NDA NDA IMO/IMDG NDA Not regulated NDA NDA NDA ADN NDA Not regulated NDA NDA NDA ADR/RID NDA Not regulated NDA NDA NDA IATA/ICAO NDA Not regulated NDA NDA NDA 14.6 Special precautions for . None known. user 14.7 Transport in bulk . Not relevant. according to Annex II of MARPOL 73/78 and the IBC Code Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 8 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+T GL(Flat and Tapered),ISO 95+TM CAN Section'l5 - Regulatory Information 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture SARA Hazard Classifications . None Sta_te Ri ht.To,Know. . - Component CAS MA NJ PA 2-Methylbutane 78-78-4 Yes Yes Yes 2-Propanol, 1- chloro-,2,2',2"- 13674-84-5 No No No phosphate Glass,oxide, 65997-17-3 Yes No Yes chemicals Pentane 109-66-0 Yes Yes Yes Inventory Component CAS Canada DSL Canada NDSL EU EINECS EU ELNICS TSCA 2-Methylbutane 78-78-4 Yes No Yes No Yes 2-Propanol, 1- chloro-,2,2',2"- 13674-84-5 Yes No Yes No Yes phosphate Glass,oxide, 65997-17-3 Yes No Yes No Yes chemicals Pentane 109-66-0 Yes No Yes No Yes Canada Labor Canada-WHMIS-Classifications of Substances • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 B2 • 2-Methylbutane 78-78-4 B2 • Glass,oxide,chemicals 65997-17-3 Not Listed Uncontrolled product according to WHMIS • Glass, oxide,chemicals as Glass wool fiber classification criteria(listed under Glass wool); D2A(listed under Mineral wool fiber) Canada-WHMIS-Ingredient Disclosure List • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 1 % • 2-Methylbutane 78-78-4 Not Listed • Glass, oxide,chemicals 65997-17-3 Not Listed • Glass,oxide, chemicals as Glass wool fiber Not Listed Environment Canada-CEPA-Priority Substances List • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 9 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM GL(Flat and Tapered),ISO 95+TM CAN • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed Other Canada-Accelerated Reduction/Elimination of Toxics(ARET) • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed Canada New Brunswick Environment Canada-New Brunswick-Ozone Depleting Substances-Schedule A • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed Canada-New Brunswick-Ozone Depleting Substances-Schedule B • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide, chemicals as Glass wool fiber Not Listed Europe Other EU-CLP(1272/2008)-Annex VI-Table 3.2-Classification • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed F+; R12 N;R51-53 Xn; R65 • Pentane 109-66-0 R66 R67 • 2-Methylbutane 78-78-4 F+; R12 N; R51-53 Xn; R65 R66 R67 • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Concentration Limits • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Labelling • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 F+Xn N R:12-51/53-65-66-67 S:(2)-9-16-29-33-61-62 • 2-Methylbutane 78-78-4 F+Xn N R:12-51/53-65-66-67 S:(2)-9-16-29-33-61-62 • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed Preparation Date: 19/Apol/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 10 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+11'GL(Flat and Tapered),ISO 95+TM CAN EU-CLP(127212008)-Annex VI-Table 3.2-Notes-Substances and Preparations • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 C • 2-Methylbutane 78-78-4 C • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed EU-CLP(1272/2008)-Annex VI-Table 3.2-Safety Phrases • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 S:(2)-9-16-29-33-61-62 • 2-Methylbutane 78-78-4 S:(2)-9-16-29-33-61-62 • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed United States Labor U.S.-OSHA-Process Safety Management-Highly Hazardous Chemicals • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed U.S.-OSHA-Specifically Regulated Chemicals • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed Environment U.S.-CAA(Clean Air Act)-1990 Hazardous Air Pollutants • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed (including mineral fiber emissions from facilities manufacturing or processing • Glass,oxide, chemicals as Glass wool fiber glass, rock,or slag fibers[or other mineral derived fibers]of average diameter 1 pm or less) U.S.-CERCLA/SARA-Hazardous Substances and their Reportable Quantities • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed U.S.-CERCLA/SARA-Radionuclides and Their Reportable Quantities • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 11 of 14 wHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM GL(Flat and Tapered),ISO 95+1 CAN • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed U.S.-CERCLA/SARA-Section 302 Extremely Hazardous Substances EPCRA RQs • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide, chemicals as Glass wool fiber Not Listed U.S.-CERCLA/SARA-Section 302 Extremely Hazardous Substances TPQs • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed U.S.-CERCLA/SARA-Section 313-Emission Reporting • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide, chemicals as Glass wool fiber Not Listed U.S.-CERCLA/SARA-Section 313-PBT Chemical Listing • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed United States - California Environment U.S.-California-Proposition 65-Carcinogens List • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber carcinogen, initial date 7/1/90 (inhalable and biopersistent) U.S.-California-Proposition 65-Developmental Toxicity • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide,chemicals as Glass wool fiber Not Listed U.S.-California-Proposition 65-Maximum Allowable Dose Levels(MADL) • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 12 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+T GL(Flat and Tapered),ISO 95+m CAN • Glass,oxide,chemicals as Glass wool fiber Not Listed U.S.-California-Proposition 65-No Significant Risk Levels(NSRL) • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed U.S.-California-Proposition 65-Reproductive Toxicity-Female • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass,oxide, chemicals as Glass wool fiber Not Listed U.S.-California-Proposition 65-Reproductive Toxicity-Male • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed United States - Pennsylvania Labor U.S.-Pennsylvania-RTK(Right to Know)-Environmental Hazard List • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed U.S.-Pennsylvania-RTK(Right to Know)-Special Hazardous Substances • 2-Propanol, 1-chloro-,2,2',2"-phosphate 13674-84-5 Not Listed • Pentane 109-66-0 Not Listed • 2-Methylbutane 78-78-4 Not Listed • Glass,oxide,chemicals 65997-17-3 Not Listed • Glass, oxide,chemicals as Glass wool fiber Not Listed 15.2 Chemical Safety Assessment No Chemical Safety Assessment has been carried out. Section 16 - Other Information Relevant Phrases (code & full text) H224 - Extremely flammable liquid and vapour H225 - Highly flammable liquid and vapour H302 - Harmful if swallowed H304 - May be fatal if swallowed and enters airways H336 - May cause drowsiness or dizziness H411 - Toxic to aquatic life with long lasting effects EUH066 - Repeated exposure may cause skin dryness or cracking. Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 13 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 ISO 95+TM+GL(Flat and Tapered),ISO 95+TM+CAN R12 - Extremely flammable. R22 - Harmful if swallowed. R51 -Toxic to aquatic organisms. R53 - May cause long-term adverse effects in the aquatic environment. R65 - Harmful: may cause lung damage if swallowed. R66 - Repeated exposure may cause skin dryness or cracking. R67-Vapours may cause drowsiness and dizziness. Last Revision Date . 17/February/2014 Preparation Date . 19/April/2011 Disclaimer/Statement of . The information contained herein is based on data considered accurate which has Liability been obtained from other companies and organizations. However, no warranty or representation is expressed or implied that the information, is accurate, complete or representative. Firestone Building Products Company, LLC assumes no responsibility for injury to the buyer, the buyer's employees, or any third persons, if reasonable safety procedures are not followed. Additionally, Firestone Building Products Company assumes no responsibility for injury to buyer, the buyer's employees, or any third persons caused by abnormal use of this material, even if reasonable safety procedures are followed. Key to abbreviations NDA=No data available Preparation Date: 19/April/2011 Format:EU CLP/REACH Language:English(US) Revision Date: 17/February/2014 Page 14 of 14 WHMIS,EU CLP,EU DSD/DPD,OSHA HCS 2012 i, FJ-1 , This document serves as formal notice that Anthony Scott Clark, residing at 11192 106TH Street, Largo, Florida 33773., is authorized to sign for the City of Zephyrhills, FL Roofing Permit for the project located at 7422 Gall Blvd, Zephryhills, Florida 33541. This authorization is granted by John Jolly Jr., CEO of Jolly Roofing &Contracting, Co. Inc. The undersigned certifies that the foregoing information is true and correct. BY: NAME: TITLE: State Of: 1VW\Q. %b County Of: SUBSCRIBED and SWORN before me on the ?� day of January, 2019, by who is personally known to me. Notary Public:` DMA S'tk'UVA �.� �E�LE Sq0 �., Name: oP� �F�� '; My commission expires: sion Expire Oete -11, 2021'� STATE OF TENNESSEE NOTARY PUS'LIC �1gMsON00��.`�`` /lotI ` �