Loading...
HomeMy WebLinkAbout19-21708 CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 21708 � f ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:21708 Issued: 10/01/2019 Address: 6503 PADEN WHEEL ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 36,480.00 Total Fees: 337.50 Subdivision: SILVERADO Amount Paid: 337.50 Date Paid: 10/01/2019 Parcel Number: 05-26121-0070-00400-0040 CONTRACTOR INFORMATION OWNER INFORMATION Name: SOLAR BEAR LLC Name: DOOLITTLE, JAMES & MARIA Addr: 6101 JOHNS RD STE 8 Address: 6503 PADEN WHEEL ST TAMPA, FL 33634 ZEPHYRHILLS, FL 33541-2551 Phone: (727)218-9407 Lic: Phone: 813-260-0072 Work Desc: INSTALLATION SOLAR ROOF MOUNTED PV SYSTEM APPLICATION FEES ELECTRICAL FEE 337.50 INSP19CTIONS REWIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. � ! ]A V11. CONTRACV& PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department r y Date Received Phone Contact for Permitting 727 940.3256 1 e I 1 I e e - - - - - - - -- 1 1-1 e 1 Owner's Name DOOLITTLE JAMES&MARIA Owner Phone Number 8132600072 Owner's Address 1 6503 PADEN WHEEL STREET,ZEPHYRHILLS,FL 3354 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6503 PADEN WHEEL STREET,ZEPHYRHILLS,FL 33541 LOT# F SILVERADO RANCH SUBDIVISION PARCEL ID#1 05-26-21-0070-00400-0040 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR B ADD/ALT SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 11AKW BUILDING SIZE I = SQ FOOTAGE= HEIGHT BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 36,480 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ 1 Q =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION I vl =GAS = ROOFING Q SPECIALTY = OTHER �6�I FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# ELECTRICIAN � OMPANYSOLAR BEAR LLC SIGNATURE REGISTERED N FEE CURREN Y/N Address 6101 JOHNS RD STE B TA PA FL 33634 License# I EC13009020 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address F License# eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Slonnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safely Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All Commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. *-PROPERTY SURVEY required for all NEW construction. Directions:' Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs If shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" ' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource.Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction-Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such.fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required.- If lam the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Sub cribe n swot jj�(or a u efore me t by V �by� Who is/are personally known to me or has/have produced is/ar personally known to W or has/hale produced DL as identification. DL as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of No ryp1inledfq6fJgrt�W bud IiC State of Florida Timothy Coffey °� pv My Commission GG 248671 V*p,,µo@ Expires 08/15/2022 @IIOSCO p P Design Overview produced'. y BlakeAmbr ster i • =4 d �v �� ,k.r a .. • .Rt � f��yP�� Jyt ��i p� � t. tint. F' ' 19,9 act +� �` ��7i�:r. ft �� �' ".�" `�8`� ` •off-�'�«y��T� y x�."�,'�F3€ °"xi- 41 Helios ' a . 2019 Folsom Labs 2J2 August 07,2019 .V. City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: � � Date Received: �ik Site: tr° d 3c" j Permit Type: f'l S•�ti I l Y-0 0'I- A40V h Luz f0A- V `S 2 Approved w/no comments Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. SEP 0 .2099 kalvidS tt fans Examiner Date Contractor and/or Homeowner (Required when comments are present) DIRECTORY OF PAGES F � Buehholz Ln SCOPE OF WORK P-120674 PV-1 PROJECT SUMMARY N THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE PV-2 SINGLE-LINE DIAGRAM aS' RACKED USING A PREENGINEERED RACKING SYSTEM.THE PV 3 SAFETY LABELS RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE X LOCAL UTILITY USING MEANS AND METHODS CONSISTENT BA--Y AREA MODULE DATASHEET WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND OPTIMIZER DATASHEET PERMITTING JURISDICTION. u.l INVERTER DATASHEET THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF W W DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH PROJECT DETAILS APPLICABLE CODES AND REGULATIONS.THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR >- W . - PROPERTY OWNER JAMES DOOLITTLE FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. Cl) IC) PROPERTY ADDRESS ZEPHYRHILLS,FL 33541 US THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS C")&5 LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL W W C'7 APN APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. �j (j ZONING RESIDENTIAL CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL O USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. J J CLASSIFICATION GROUP(GROUP R3) AHJ _ ,. ;,__ ._ ae�, ots SYSTEM DETAILS UTILITY COMPANY PROGRESS ENERGY FLORIDA INC 1 NEW GRID-INTERACTIVE PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO CU) 0 >- ELECTRICAL CODE 2014 NEC(NFPA 70) BATTERY STORAGE PV1 SCALE:NTS FIRE CODE 2015 NFPA 1 DC RATING OF SYSTEM 11,400W W Cl) W AC RATING OF SYSTEM 10,000W W N CONTRACTOR INFORMATION H L AC OUTPUT CURRENT 42.OA COMPANY BAY AREA PROJECT SOLUTIONSr INVERTER(S) I X SOLAR EDGE SE10000H-US LICENSE NUMBER 0 MODULE SILFAB SLA300M ADDRESS 2512 BAY FIELD CT,HOLIDAY,FLf Zephyrhills ARRAY WIRING (2)STRINGS OF 19 34691 PHONE NUMBER (727)543-8361 rr e ' . « INTERCONNECTION DETAILS DATE 0 . 10 _ CI F 7.EPHYR CONTRACTOR C�Sa SIGNATURE POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECR XAII44INER CtyI2-Hitts Q UTILITY SERVICE 1201240\ ODES L C0M i WITH �e, AI^Zephyrhills ' ~r SITE DETA S 'LLS ASHRAE EXTREME LOW 1°C(34°F) ASHRAE 2%HIGH 34°C(93°F) PROJECT Ct81 Spnnge CLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) SUMMARY WIND SPEED 160 MPH(ASCE7-10) , �9C� 2 LOCALE RISK CATEGORY II DOC ID:120674-150771-1 DATE:8/14/19 PV-1 SCALE:NTS WIND EXPOSURE CREATOR: i CATEGORY GROUND SNOW LOAD REViEWER: REVISIONS Pv-1 -; + -- MODULES - GENERAL ELECTRICAL NOTES P-120674 OPTIMIZER REF. OTY. MAKE AM MODEL PMAX Prc ISC I IMP I VQC I WPTEMP.COEFF.OFVOC FUSERATNG UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL I ! PM1J6 36 SLFAB SLA300M N 270W 9.71A 9.16A 6v 3Z - 12 FC(-0 ) Z0A 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE PM,-38 INVERTERS SERVICE ENTRANCE. Q Q TY MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENTMAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY 19 N i 1981 300W 0 0 " 1 SOLAR EDGE SEI0000H� 24W UNGROUNDED 60A 10,000W 42AA 27.5k46DV 99.0% 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. I I NG Q® POWER OPTIMIZERS CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS ( + I + $ REF QTY MODEL RATED INPUT POWER MAxouTPurouRRENr MAXINPUUTISC MAX DC VOLTAGE WEKRITEDEFFICIENCY 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND P0136 38 SOLAR EDGE P320 320W 15A 11.5k4EV 9Lex ARTICLE 310.8(D). ( I PASS-THRU BOXES AND COMBINERS CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE ND REF. OTY. MAKE A MODEL RATED CURRENT MAX RATED VOLTAGE 1 1 GEIERICGEN•AWB.TB44XOREDUIV. 30A 240VACI600VDC 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE DISCONNECTS OCPDS 310.8(C). NM�T10N I3OX REF. QTY. MAKE Alm MIODE RATED CURRENT MAX RATED VOLTAGE I REF. OTY. RATED CURRENT I MAX VOLTAGE LLJ LIJ L__1 J81 SWI I ii AID 00222NRD OREQUN. SM I 2mVAc FI 2 I 2 I EM 240VAC I GROUNDING NOTES U SYSTEM SUMMARY NOTES z ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE �- z STRING 1 SIRING 2 ©OPnMOZFRS PROVIDE RAPo SHUTDOWN FUNcnONALITY REQUIRED By NEC 600.12 1 REQUIREMENTS OF NEC ARTICLES 250&690 LLJ d" INVERTER MAX OUTPUT CURRENT ISA 15A ( IN sET9ES 19 19 THE SPECIIED OPTIMIZER CAN BE SUBSTITUTED YATH A P400.P405,P370,PS05,OR P340.THESE oPnMUERS HAVE AN II'UT VOLTAGE WNDOW WIDE ENOUGH TO PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS LL M 11 10,000W STRNNG VOLTAGE 400V 40W L ACCOMMODATE THE OUTPUT VOLTAGE RANGE OF TIRE MODULE AT THE DESIGN TEMPERATURES,HAVE A MAX INPUT CURRENT RATING THAT IS ABOVE THE MAX LLI C M USING MODULE LUGS OR RACKING INTEGRATED Y OPERATING CURRENT 14?A 14.2A OUTPUT CURRENT OF THE MOOR E,AND A MAX POWER INPUT THAT IS ABOVE THE RATED POWER OUTPUT OF THE MODULE ~ LL ( + SIC POWER 11,400W 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. LL j _ ILAPIOAYPTC POWERCUR 10 ®uu SYSTEM DC Rs Co►mUCTO SHALL BE COLOR.=ED AS FOLLOWS.DC POSITIVE SHALL BE RED(OR MARKED RED)AND DC NEGATIVE SHALL BE BLACK ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED 0 W L' AC POWER OUTPUT 1oCA w ( ) USING UL-LISTED LAY-IN LUGS. J r J TED AC POWER OUTPUT 10,000W ALL METAL ENCLOSURES.RACEWAYS,CABLES AND EXPOSED NONCUR ENTr,MRYING METAL PARRS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRE INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS I I A BY NEC 250A(B)AND PART III OF NEC ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45.THE GROUNDING BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 ! I UOOEBYSHADH47(B)AND250.169.TEDCGROUNDNGE[ECRODESHNLBESIEEDACCORD84GTO250.166 3 °GROUNDING AND BONDING"WHEN USED WITH PROPOSED 0 Q --- 9 AN ADDRIONNLARRAY GROUNDING ELECTRODE SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTIONS 250.52 AND 25054 UNLESS TIE ARRAY STRUCTURE I5 PV MODULE. 0 ®SUITABLE TO SERVE AS A GROUNDING ELECTRODE AS PER NEC SECTION 2502.THE LOAD SERVED BY THE ARRAY NS INTEGRAL WITH THE ARRAY,OR THE PREMISES ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED Cl U -2 EXISTING vrINING ELECTRODE IS LOCATED WIFION OFT,AS PER NEC SECTION 690.47(D) 4 LL.J I Lu L__, DISCONNECT FOR THEIR PURPOSE _ co Lu ®MAX DC VOLTAGE OF ARRAY FIXED BY THE OMERTER AT 400V REGARDLESS OF TEMPERATURE.THE MAX DC VOLTAGE OF THE MODULE AT 1'C IS EXPECTED TO BE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A I- LLJ N 42.7V(1'C-25'C)X O.IZ WC+39.651/=42.7V). ( 4 PV SYSTEM M DISCONNECT SHALL BE AVISIBLE KNFEBLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILIY.THE DISCONNECT SHALL BE 5 VERIFIABLE GROUNDING ELECTRODE,TINSTALLIT IS THE p ( ►MSP WnooA Mcs) LOCATED WITHIN FT OF UTILITY METER. CONTRACTOR S RESPONSIBILITY TO A SUPPLEMENTAL GROUNDING ELECTRODE. I ( HARDWARE EON NECPLY SIDE of SERVICE DISCOkNECT,Ar A LOCALLY-A?PROVED CONIEcnoN POINT,USING LOCALLY APPROVED METHODS A D AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC HARDWARE•N COMPLIANCE WITH NE 106.12(A). ) Laws F ECTION Is oN THE6 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS IF BARE WIRE. -}- Q CONDUIT/ CURRIW-CARRYING TEMP.CORP. FILL CONT. MAL CURRENT BASE DEBATED TER . AM P.N TERM. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED TYPICAL CONDUCTOR CONDUCTORS IN CONDUIT/ OCPD EGC CABLE CABLE FACTOR FACTOR CURRENT (125%) AMP. AMP. TEMP.RATING TEMP.RATING 1, (m(I►Y METER A& 1 2 10 AWG Pv WI E FREE MR Na N/A AWG BARE coPPaN 7I(5C) 1.0 15A 16.75A s5A 39 05A .c 7 ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF KwHR 240/120V 1N),3W COPPER #10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG GEC 2 1 t0A 2, o r5'DIL LFNC 4 NA 1O A z 0.71(56C) 0.6 15A 16.75A 40A 2272A 90°C 40A SHALL BE USED WHEN EXPOSED TO DAMAGE 6AWGIHNWIL2, 10AWGTHIM,2. GROUNDING AND BONDING CONDUCTORS,IF INSULATED, 3 1 COPPER 0.75 DW LEND 2 NA COPPED 0.96(34-C) 1.0 42A 525A 75A 72A 75'C 65A 6ACOPPER-- 1oAwGTINwN2 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF 4 1 _COPPERTHIN 0.75'DA.LFNC 2 60A x 2 WG T}WIPER 0.96(34-C) 1.0 42A 5z5A 75A 72A 75'C 65A #4AWG OR LARGER SINGLE-LINE DIAGRAM PROJECT ID: 120674 DATE: 08114/19 CREATED BY: SDT CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV-2 SCALE: NTS I THIS DOCUMENT HAS SEENCtEATED FOR THE PURPOSE OF DESCIDIG TIE DEIGN OFAPROPOS D PHOTOVOLTAIC POWER SYSHEMMATHEN000H DETAL TO DEMONSTRATE COMFLUNCEWRN ALL APPUCASLE CODES A/D REOIAATKNS.THE DOCIH�ENT SIA)UD NOTBE ELMS UPON AS A SUBSTITUTE FORPV-2 FOLLOWNG MAMIFACRWER IETALRATION MANUN.S.INSTALLER SHALLII TALL ALL EOUPABBT N ACCORDANCE WITH WNJFACERER INSTALLATION MANUALS.NOTTERi N THISDOCUIENTSHOILD BEINTERPIETED IN A WAY THAT OVERRIDES THERL4TRUCTIONSIN MAWFACTIJR®1NSTALLAT 1 MANUALS DC RACEWAYS POINT-0F-INTERCONNECTION OR AT MAIN O UNGROUNDED CIRCUITS MAY BE EXPOSED H DEVICE WHERE ENERGIZED, LABELING NOTES P-120674 1 SEE NOTE NO.4(DC RACEWAYS) Z SERVICE DISCONNECT(MSP) DURING SERVICE.(JB1,11) ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015 NFPA I WILL BE INSTALLED AS REQUIRED. IcAVfl N! . Y hI ___ LABELS,WARNING(S)AND MARKING SHALL COMPLY ��.. JB1-TRANSITION BOX WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, MODEL NOT SPECIFIED) WARNING,AND CAUTION SIGNS USED THE STANDARD BAY AREA HEADER COLORS,HEADER TEXT,AND SAFETY ALERT 7t SYMBOL ON EACH LABEL.THE ANSI STANDARD O O �fi REQUIRES A HEADING THAT IS AT LEAST 50%TALLER NEC 690.31(GX3) AND IFC 605.11.1 NEC 690.56(B) NEC 690.35(F) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). W W I1-INVERTER O EACH DISCONNECTING MEANS FOR DC DISCONNECT(11) ( ) AC SOLAR DISCONNECT(SW1) A PERMANENT PLAQUE OR DIRECTORY SHALL BE I-- 0 SOLAR EDGE SEI0000H US PHOTOVOLTAIC EQUIPMENT(J81,h) ^ INSTALLED PROVIDING THE LOCATION OF THE SERVICE (f) Z 3 4 5 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC >- W SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). M i LABELS "WARNING PHOTOVOLTAIC SW1-DISCONNECT LABEL(S)WITH MARKING, EATON DG222NRB) POWER SOURCE;SHALL BE LOCATED AT EVERY 10 LL OF EACH DC RACEWAY AND WITHIN ONE FOOT OF O (II:) (:I ) O EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE NEC 690.17(E) NEC 690.53 NEC 690.13(8) 4 AND BELOW ALL PENETRATIONS OF ROOF/CEILING J Cl) ASSEMBLIES,WALLS AND BARRIERS. THE LABEL SHALL I- _J MSP-MAIN SERVICE PANEL O SEE NOTE NO.5(SW1) O ANY AC ELECTRICAL PANEL THAT IS FED BY HAVE 3/8"TALL LETTERS AND BE REFLECTIVE WITH I- -J AC DISCONNECT(SW1) O BOTH THE UTILITY AND THE PHOTOVOLTAIC WHITE TEXT ON A RED BACKGROUND J = SYSTEM(SW1,MSP) LABEL(S)WITH MARKING,"PHOTOVOLTAIC SYSTEM 0 IY EQUIPPED WITH RAPID SHUTDOWN;SHALL BE LOCATED (� 0 >- 5 AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/8"TALL O ai LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A W (f) RED BACKGROUND I'- W N NEC 690.56(C) AND IFC 605.11.1 NEC 690.54 NEC 705.12(DX3) O 0 SAFETY LABELS DOC ID:120674-150771-1 DATE:8114/19 CREATOR: REVIEWER: REVISIONS PV-3 { ;• aiste »+K:* a Test Conditions NOCT wZ ��i Module Power(Pmax) Wp 3OO227 s„z Maximum power voltage(Vpmax) V 29.5 ' Maximum power current(I max) A 7.69 Open circuit voltage(Voc) V W 36.9 Short circuit current(Isc) A ) 7.96 Module efficiency % 1_+ 17.3 Maximum system voltage(VDC) V 1000 Series fuse rating A 2O Power Tolerance Wp -0/+5 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25'C•NOCT 800 W1m'•AM 15•Measurement uncertainty 5 3% ®e •sun simulator calibration reference modules from Fraunhofer Institute.Bectrica characteristics may vary by*5%and power by-0/+5. CtSL atnarioe ,ar•re Temperature Coefficient Isc %/K ) ' Temperature Coefficient Voc %/K -030 Temperature Coefficient Pmax %/K NOCT(t 2°C) °C 45 • $ * INDUSTRY LEADING WARRANTY o eras hem rature 'c All our products include an industry leading 25-year product workmanship Module weight(*1 kg) kg Dimensions(H XL X D;t 1 mm) mm 1650 x 990 x 38 and 30- eaf performance Warranty. Maximum surface load(wind/snow)* N/m2 24OI S4Q a dowiwmrd 35+YEARS OF SOLAR INNOVATION Hail Impact resistance a 25 mm at 83 km/h Cells 4611T • Leveraging over 35+years of worldwide Glass 3.2 mm high transmittance,tempered,antireflective coating j $ / experience in the solar industry,Silfab Backsheet Multlla er polyester-based is dedicated to superior manufacturing Frame processes and innovations such as Bypass diodes 3 diodes-45V/12A,IP67/IP68 Bifacial and Back Contact technologies, cables and connectors(See installation manual) to ensure our partners have the latest in Module product workmanship warranty solar innovation. 30 years QUALITY ≥97%end of t*year NORTH AMERICANa Linear power performance guarantee ≥90%end of 12'"year Silfab is the largest and most automated ≥82%end of 250,year solar manufacturer in North America. ≥80%end of 30th year Utilizing premium quality materials and strict quality control management to deliver ULC ORD C1703,UL 1703,IEC 61215,IEC 61730-1 and IEC 61730-2 Certified. the highest efficiency,premium quality PV Product FSEC and CEC listed.IEC 62716 Ammonia Corrosion,IEC 61701:2011 Mist Corrosion 100%made in North America. Saltion Certified UL Fire Rating:Type 2(Type 1 on request) = Facto *Please refer to the Safety and Installation Manual for mounting specifications. **12 year extendable to 25 years subject to registration and conditions outlined under 'Warranty at www.sdfabsoiar.com. it A Warring•.Read the installation and User Manual before handling,installing and operating • modules. • Third-party generated pan flies from �q_ fit Modules Per Pallet 26 1 ' • • • t• ••• • Fraunhofer-Institute for Solar Energy {# 81 Pallets Per Truck 36 Systems ISE are available for download at: N 16 Modules Per Truck:936 www.siifabsolar.com/dowMaads fff111 4 rroa.e � .euwn.soorwo w • . n • t •r s c-e F•rrwk. z i sifab solar Inc. • • • rys 240 Courttteypark Drive East sZ.. Mississauga ON L5T 2Y3 Canada Si If b,"" Tel+1905-255-2501 1 Fax+1905-696.0267 0 "a•-°•-r— soul info@silfabsolarcom I wwwsiifabsolar.com "°"""�""" °•�'°'r'°"' i ®® Silfab Solar Inc 800 Cornwall Ave Bellingham WA 98225 USA Tel+1360-569.4733 H I Power Optimizer For North America P320/ P340 / P370/ P400/ P405 / P505 w ' ' z For #o h Am ca P320 P3 P3Q I P4fl5 P5fl5 r'n ________________________________ ____ Rated Input DC Powers" 320 340 370 400 405 505 W Absolute o Maximum Input V 48 60 80 125m 83°d Vdc (abc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-83 Vdc ) : :....,.... .. . i: ..:.:(:) . )imam Short Circuit Current 11 10.1 14 Adc t w�) huI Maximum DC Input Current 13.75 12.63 17.5 Adc ;. '" ; Maximum Efficiency 99.5 %Weight 986 : ervoed Efficiency 988 l[age Category OvII II tHl1P1tT'IJ1)ft}WtG0PEItAN(POWER OPTIMIZER CONNECTED TO OPERATING LA1tEE?GE INVERTER) >.. Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc �:.. tJt#TPUT DURING STANDBY(POWER OPTIMIZER f)kSGf?NNECTEb FROM SOI.AREDGE INVERTER ORSOLAREDGE tN5t1~iCTE}t i7FF} Safety Output Voltage per 1±01 . Vdc Power Optimizer SThNDARD COMlilE -•s FCC Part15 Class B IEC61000-6-2 IEC61000-6-3 EMC • Safety 09-1(dass ll safety),U12741 lEC6Z1 RoHS Yes 3ft}STAltA'i'iO1°l SPECIfICATIONS Maximum �ge Allowed System � 1000 VO Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimerisons(Wxl.xH) 128x152x28/Sx5.97x1.1 128x152x36/ 128x152x50/ 128x152x59/ mm/in Sx5.97x1.42 Sx5.97x1.96 5x5.97x2.32 Weight(including cables) 630/1.4 750/1 7 845/1.9 1064/23 gr/lb Input Connector MC4m Output Wire Type/Connector Double Insulated;MC4 Output Wire Length 0.95/3.0 1.2/3.9 m/ft IIII Input Wire Length 0.16/0.52 m/ft Operating Temperature Range -40-+85/-40-+185 C/'F PV power optimization at the module-level Protection Rating IP68/NEMA6P Relative Humidity 0-100 % "Rated SIC power of the module.Module of up to+5%power tolerance allowed m NEC 2017 requires may input voltage be not more than SW / Specifically designed to work with SolarEdge / Fast installation with a single bolt nForot+erconnectmtypespleasecomact5obrEdge inverters I Next generation maintenance with module- / Up to 25%more energy level monitoring P320,P340,P370. 8 10 18 Minimum String Length P400 I Superior efficiency(99.5%) / Meets NEC requirements for arc fault (Poptinxzers) P405/P505 6 8 14 protection(AFCI)and Photovoltaic Rapid Maximum String Length 25 25 500 (Power imizers) I Mitigates all types of module mismatch losses, Shutdown System(PVRSS) 5700(6000 with from manufacturing tolerance to partial Maximum Power per String SE7600-US-SE11400- 5250 6000°^ 127500W shading I Module-level voltage shutdown for installer Parallel Strings of Different Lengths US) Yes and firefighter safety or Orientations / Flexible system design for maximum space w For detailed string sizing information refer to:htrp'pw5olaiedge.com/utesIdetadtP9es/Strbsg.afabgji&pdf m It is not allowed to mix P405/P505 with P320/P340/P3701P400 in one string utilization e A stray with more than 30 optnnizers does not meet NEC rapid shutdown requirements safety voltage wA be above the 3W requirement °n For SE14.4KU5/SE43.2KUS:It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter(3 strings per unit for SE43.2KU5)and when the maximum power difference between the strings is up to L000W •For SE30KU5/SE33.3KU5/SE66.6KU5/SE100KU5:It is allowed to instal up to 15,000W per string when 3 strings are connected to the inverter(3 strings per unit for SE66.6KUS/SE100KU5) and when the maximum power difference between the strings is up to 2A00W solaredge.com SO l a 9 O sewteyet exnteyMs tm Ait dgl is reeevvd SDU REDGE tire set.cdae togis O► lED n souREDGE re.,arena to or egineed vede eks of saeFdge Tedxnlog es 6c AR ahmbodenrx.e,reWned Morin are fndenwhs ofdreir reyecteu.me,cDm:13/m16/WLENG NAM Subject tedwgeril6ddnotix. CE RoHS I Sin le Phase Inverter -wit HD Wave Technology for North America SE3000H-US/ SE3800H-US / SE5000H-US/ SE6000H-US/ Single Phase Invet rfli SE7600H-US /SE10000H-US/ SE11400H-US with HD-Wave Technology 3800@240V 6000 @ 208V 11400 @ 240V Output @ 208V 5000 @ 20$V 10000 @ 208V Rated AC Power 3000 3300 5000 7600 t00t)0 t VA I 3$00 @ 240V 6000 @ 240V } ( 11400 @ 24pV VA Maximum AC Power Out t 3000 5000 7600 ,0000 1 Mm:Nom.Max l ! 0000 @ 208 Vac � 3300 @ 208V 5000 @ 21,)8V 0211 240for North America r`2e I ✓ ' 1 i ✓ 7 SE3000H-US/SE3800H-US/SE 00H-US/>5E60001-1-US/ ,. „ 183-208-229) i I i SE7600H US I SO dbWWUS/SEI 400H US AC frequer+cy(Nom naq 59.3-60-60.Sr' Hz Maximum Continuous Output 125 16 21 25 } 32 42 47.5 A Current @240V f Maximum Continuous Output - - Current @208V 16 I 24 48.5 A GFDI Threshold 1 ( A w ,RUtil Utility Monitoring(standing x °§ a Protection,Country Configurable �s Thresholds hi x§ om} Maximum DC Power @240V 4650 5900 7750 93(X) ! 11800 15500 17650 W Maxurxun DC Power @208V 5100 7750 15500 i W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc • Maximum Input Current @240Vn 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V' 9 13.5 27 Adc Max.input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600W Sensitivity i Maximum Inverter Efficiency 99 } 992 CEC Weighted Efficiency 99 I 98 5 @2208V % W Nighttime Power Consumption <2.5 <:, AtipiTt C?NAl fEATURES is Revenue d Data,en ANSI Cn faaces 2 Opt ona RS485,Ethernet, onaq,Cellular(optional) 1220 lo' Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect Optimized installation with HD-Wave technology 201769012 sr�roA�a cc Safety UL1741,UL1741 SA,UL16996,CSA C22.2,Canadian AFC(according to TIL M-07 I Specifically designed to work with / Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) power optimizers Emissions FCC Part 15 Class B I Record-breaking efficiency I Built-in module level monitoring !!5 TALI At1 N SPECIFICATIONS AC Output Conduit Size/AWG 3/4'minimum/14-6 AWG 3/4'minimum/14-4 AWG Range I Fixed voltage inverter for longer strings I Outdoor and indoor installation DC input Conduit Size/*of Strings/ 3/4'minimum/1-2 strings/14-6 AWG 3/4'minirnum/1-3 strings/14-6 AWG f AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8/450 x 370 x 174 ; 21.3 x 14.6 x7.3/540 x 370 x 185 j r I integrated arc fault protection and rapid shutdown for I Optional:Revenue grade data,ANSI C1 2.20 a*W)a NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) Weight with Safety Switch 22/10 zs?/11.4 262/17.9 38.8/17.6 Noise <25 <50 dBA I UL1 741 SA certified,for CPUC Rule 21 grid Cooling Natural Convection compliance Operating Temperature Range -40 to+140/-25 to 60w(-40'F J-40'C option)e- Protection Rating NEMA 4X(lrwerter with Safety Switch) For otter regional settvgs please contact Solarfdge support s o I a r=evA higher cunmt source may be used the inverts wit m t its Kx8 cur ens to the vak es stated solaredge.com t'For powRevenueer de-rradeat'rig Iforr niaalticn refer to: :h i/ ault/sies/se-tm+ ratite-derati -note-re. 9 a,-40 on PM:SExxwhl-US000lJN114 J/� . zomkitesJdef pe rg. pdf or vad�m.t m alt v otme. twe txow sautttocE am atsd+ x curs ReIt,reoHS . . BNrIFFW101xrrlt. l/�IRONRIDGE Roof Mount System -, 1 1 JhOPB►RashhtgPlaartltlK � __ _ _ 70MORtI xRIMRY 7011M01Y1 RolriaONyltBa 1 RONOMMPAL Ar R11FiBi NTAl1 tlaArl0 t A t; i 893D4V em 1WMEOr— I aoov rIrr j tti A� MAL) I 1 1 (• wa ..usrr•aay t I 1 Ac*, InDeM 7MuUraYwYlter AOt._.._ EBIIUI�IllO AlMatwk�MIW�/Isa - ts+rwun-0Bwolaeodla rte E r 1I mICI ms ma I6L rr4 Yr w1htt oOltrYBNpRr0AlI11RIt= 1Dta1BAYIa00laN0l0llt. r ; uaPara IRIDGEPVRAILGENERICINSTALLATIONPLAN COPsraigelP�d rtpaattpagdEy •iNlsFNE104BPtlIIP •6tIrMVaoBtlt . 1. THIS'PAPER'PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION •N&hwbio wp*AW •IMNbrlelplMr •BIItBmaladeapWlgr •YtryYlBrubnalxsYt 1 OR WllOffiIEAaP1Yir 1# • wvuk . .Pam4otourYDnEtB !: i slrsaERx� 1 NEEDED BY AHJ(AUTHORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT)AND 'Y MA INSTALLERS.CONTRACTOR SHALL INDICATE TO AHJ WHICH METHOD HE/SHE WILL USE. tROB SW,-lrawP isaruatrw IRoraBrrlrrlm 2. THIS PLAN SHALL BE USED SOLELY FOR PROJECTS IN AREAS WHERE WIND SPEED IS t0 CJ 4MMATTAE!MT y�? 1 Vult 170-MPH OR LESS.INSTALLATIONS IN HIGHER WIND AREAS SHALL REQUIRE nanaxlaRwlPnwTwrTARaET 1 )'# SITE-SPECIFIC ENGINEERING. aePnAawq^T 0*_fl I la 3. THIS PLAN OFFERS THREE INSTALLATION METHODS. 1°�r® ^ ` �Oi ION 0 �Ycof =A a.FRAMING METHOD.SEE DRAWINGS. - "` -' )s i - '!8CFAVPAT 1 w b.SHEATHING METHOD.SEE DRAWINGS. �� ��vrlreww Ly,ay,yra, t f c.STANDING SEAM/PBR(PURUN-BEARING)METAL ROOF.USE CLAMP/BRACKET OF 12 Mn A1dTtacxsnn6lE xrt RAa CHOICE; ACE.http://www.pmdnd.com/aceclamp/ : pnd. a mp/ worwooEr+oar S S.https//wwWs S c_ odueu/damPs bradceu/s 5 u dam s/ JL i sa°®°rr. wr httPs:j/www.s S.com/products1dam s bradceWProteabracket/ iTlOtd Hesdltt But }yr,t.r�y 4. CONTRACTOR SHALL MAKE CLEAR TO AHJ WHICH INSTALLATION DETAILS WILL BE liV R.ORICAROOFATTACI NT$PACIIG(TT:ROOF1EIGHY<»Fr S ROOF SLOPE<ao• 2 esnroru r 1 wrp.�aMr USED. i rw 5. SOLAR EQUIPMENT ADDS LESS THAN 4 PSF GRAVITY LOAD TO STRUCTURE. WIND(rr_ P21 P22 P28 IR_NRIOGE RAI. 15€ 1M 16 ` earn aPAcse THER E ERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL 110 e a 4 XR•10 1 ('a'^e00"IO3 11 M IsliiLJ CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE.ADJOINING MODULES SHALL 120 a a 2 XII-10 85%6 i I �.�- ryrr.sa.t t6eitee SHARE MID CLAMPS.MODULES MAY BE LANDSCAPE OR PORTRAIT AT CONTRACTOR 130 6 4 2 XR400 - ,! e von .E EIlEIOII16fll.i) OPTION. Loo 6 4 2 xR-100 5M MIND" i • i at�runur,r :r ems rotted 7. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. 150 0 4 2 XR-1OO 3-INCH I o� i! I I 1 1EP00F •1.s-I10 8. RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF ATTACHMENT BY 170 4 4 2 xR 1000 11NBEDB tR J . i.',I z "�OOOa` kp� sa.sod.I>W.B..roraaoo 9.MOR RAILS SHA TERNATELY ATTACH TO ROOF THRU IRONRIDGE L-FEET AND ROOF IICNOGERHEV0OTt APRIDKDIETALADOP41MWaMACIPeTL 1 i RODFTBu�aralBtalarAUArnsloErAtB teo 11 �� � �� '�`/ t' � �� TECH RT MINI ROOF ATTACHMENTASSEMBLY AS SHOWN LN FIGURE 02CONTRACTOR ssiw _ l� C°'- - SHALL ENSURE THAT THE EXISTING ROOFING,ROOF SHEATHING,RAFTERS/TRUSSES AND rnrwoaeieoorramrarararoasorana 13 sum� OTHER STRUCTURAL MEMBERS CAN SUPPORT THE ARRAY UNDER ASCE 7-14 CODE LOADING CONDITIONS. 10. 1-FEET REQUIRE FLASHINGS WHICH CAN BE RT MINI BUTYL TAPE(FIG.02)OR MIN 4" x 8"x 26 GA.GALV,0.032 ALUM,OR INDUSTRY STANDARD OEM FLASHINGS OVER NN NDIIULE Fyn RmOi ATTACHMENTS LAGGED INTO ROOF FRAMING OR SHEATHING-ONLY(FIG.02),E.G.SOLAR MOUNT,IRONRIDGE FLASHFOOT 1 OR 2,OTHER ACCEPTABLE TO AHJ. PV RAIL OOST 3/8-16x3/4 HEX HE BOILS PV ML 11. CONTRACTOR SHALL REFER TO ASCE7-14 WIND PRESSURE ZONES INSTRUCTIONS PV RAIL 3/8-16 x 3/4 ROOFTI E 3/8 RJEJfiEfIlf (FIG.09)AND THE IRONRIDGE RAIL SPAN TABLE(FIG.13)FOR APPROPRIATE WIND SPEED, HEX HEAD BOLT PV MO _ _ ROOF ZONE,&RAIL,C-C ROOF ATTACHMENT SPAN. 3AT-16 RANGE NUT OOSL lETAt SaRA � O[q�(: 12. All FLASHINGS SHAH BE INSTALLED IN A GENEROUS BED OF FLORIDA PRODUCT i DROOP CONTROL APPROVED(PCA)POLYURETHANE ROOF SEALANT. 1-FOOT ROOF RoOFJSiIJfl SHEATHING 13. LONG L-FEET&/OR STANDOFFS ARE PERMITTED AS NEEDED FOR ROOF CLEARANCE. TILE EN METAL PLATE, SQUARE OR ROUND ROOF SHFATHDlG SE NOTE#10 NasuvmwRH WATER ROOF �rtaNNL Dow Paw PROOFING FBC 2017 *LJ EDITION) HEATHING N81T9HNMIOOF0IG 1XISTINGRw4rt1G CODE' FBC ( TH EDI 9fiSL NG 04GLE MILE FOAIsI FFRRAMI G L Tremw PearmOFoax x INBNOOOII 3015f,OR71a1SS FLORIDA BUILDING CODE St4NfsI.E ROOF FLORIDA PRODUCT 4 TMNII8J4 APPROVED SPJY.ANT FOUR#14 CR5 aM1KLral H100FAT S0)*RI1r Ot wooroaAtlaBaaAo4 �r wwaeRr. �y�+ t i y��j# � #12X2-INOL, EXISTING 5CREVJS1'BEYOND camas wrE•• WIND: DESIGNED FOR Yu11•'• 70MPH., S%Sw UNDEW.AYMENT BOTTOM OF om # {; aHBxAl TxR SOME PLY _ _ 04 RAT TM ROOF ATTACH___ RISK 1 f,EXPOSURE CO3 . ....ers 3/8-16x3/4 PV RAILw HEX HEAD BOLT, _ RASH 22 -HI S$.RGURE 11 FLAtKsE Nllf n Pv FWI1NOt ti�NTBN!{T'<6s2T7 a '" I CERTIFY THAT THE$HEATING AND FRAMING OF TIiIS ASPWLLT a. STRUCTURE WILL SAFELY ACCOMMODATE CALCULATE i�oF %' '.%. �""' WIND UPLIFT AND LATERAL FORCES ry- .. ., . .y-�.«. {.. To B`t MY SIGNATURE AND SEAL Ofit THIS DRAWING 1 SS P c yr „, �. Atdt3 EQUIPNIEt T UEAt3 LC7ADS.THIS 1S ATT€5TEfl RooF 17(LBTTNG BMIBIDdnsT'1 OtIMRoaI <Bs+s•T ` •>" ' l SHEATHING FRAMING METAL �.e..,. a�« o,"„". AT THE LOWER RIGHT BOTTOM. 5/16"CIS.LAG W/3" 61M7 X 251M4 BE PBR PROFILE METAL SHHET SCREW Pzt:ROOROOFPERI ER -� THREAD (SAL EAVEHExi5ffOR1O4BlILOBxiUYN. ET BlAOONG Jt)i5T,ORTI61raS ®Ra6r+P0O72aH91 ER00FATTACI6GHT a6 R10tEA BRACKETO VAL ROOFATTAQR P Erf! L&W•PB. WDTP 5eEAVE HEIGHT. sousra swerns ►seaawoowwwerraCL400m woRweulewea seers - . Designed For SEAL: PHOENIX MEP CONSTRUCTION, LLC Description: Solar Panel Details i SHEET Jose WrIp Location: FLORIDA Regist x`ed Arch 818 CHESTNUT STREET Lic # OO1211 CLEARWATER, FL 33756 Date: 05/18/19 SOLAR BEAR Revision Date: = _ Phone: (813) 251-3100