Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19-21713
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21 7' 3 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 21713 Address: 7210 OMEGA CT Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ALPHA VILLAGE Est. Value: Parcel Number: 35-25-21-0050-00000-0740 Improv. Cost: 4,556.00 OWNER INFORMATION Date Issued: 9/09/2019 Name: OGDEN, DENNIS & LISA Total Fees: 97.50 Address: 7210 OMEGA CT Amount Paid: 97.50 ZEPHYRHILLS, FL. 33540 Date Paid: 9/09/2019 Phone: 813-710-6777 Work Desc: INSTALLATION 8 WINDOW S/S CONTRACTORS APPLICATION FEES WINDOW WORLD OF TAMPA BAY LLC BUILDING FEE 97.50 CL Ins ections Required FOOTER 2ND ROUGH PLUMB MI INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. Q. G GNATURE PERMIT OFFI R RMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER IIII r I I City of Zephyrhills BUILDING PLAN REVIEW COMMENTS i Contractor/Homeowner: (,r�j� do LL/ Date Received: i Site: cV. Permit Type: a 5�7.e - Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet s 11 be kept with the permit and/or plans. 1 SEP vm Switzer—Plans Examiner Date Xe�yuit*hen d/or Homeowner comments are present) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting ($13)727-6072 ft ■ I Owner's Name . Lisa Ogden Owner Phone Number 813-701-6777 Owner's Address 7210 OMEGA CT. ZEPHYRHILLS, FL 33540 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 7210 Omega Ct Zephyrhills,FL 33540 LOT# 74 SUBDIVISION ALPHA VILLAGE ESTATES . PARCEL ID# 32-27-16-94093-003-0090 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR ADD/ALT Q SIGN 0 Q DEMOLISH INSTALL e REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME Q STEEL DESCRIPTION.OF WORK Replace Size For•Size 8 Window(s)-NON-Impact. 15819.8; 16092.9; 15816.6. BUILDING SIZE SQ FOOTAGE= HEIGHT BUILDING $ 4,556.00 VALUATION OF TOTAL CONSTRUCTION " =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS $ FLOOD ZONE AREA YES NO BUILDER % �` COMPANY Window World of Tampa Bay,LLC SIGNATURE REGISTERED Y/N FEE CURRENT LY/N Address 10741 Endeavour Way#C Seminole,FL 33777 License#. SCC131151663 ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURRENT YIN. Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/N I FEE CURRENT Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N I FEE CURRENT Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N I FEE CURRENT Y/N Address License# 1 f1 I f1 III II II II II . I I I I I I' I" I I "I a I I I I I I a I I I I 1 1 -1 1 1 1 1 1 1 1 1 1 1 .1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities•&1, dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. ■ ■ - Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Noticerof•Commencement.is required.,,(A/C upgrades over$7500) ** Agent(for the contractor)or PoWer`of Attor`ney.(1or.th'e eWner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING,,—„ ;(copy of contract,required) Reroofs if shingles =; ;Sewers., ":,.$erv"ice 1)pgrades:,.A/C *Fences(Plot/Survey/Footage) Driveways-Not over Counter if on pufilf6'PoiidWays::needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:- If the*owner P has hired'a contractor or contractors to undertake work, they may be required to be licensed in.accordance With state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a-misdemeanor violation under State law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensifig Section at 727-847- 8009. Furthermore, if-the owner has hired a contractor* or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION.IMPACT/UTILITIES IMPACT- * AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as arnended. ' The undersigned also understands, that such fees, as may be due, will be identified at the'time of permitting. It is further underistood,that Transpo *rtation Impact.Fees and Resource Recovery Fees,must be paid prior to receiving a "certificatia-of oc-cupancyo or final power release. If the project-does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance With applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,as amended): If valuation of work Is$2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law--Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application-is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards'of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the'regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,. Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-W611s, Wastewater Treatment, Septic Tanks. I . - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone'V'unless expressly permitted. If the fill material is to be used in Flood Zone "K, it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in .Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. if fill material is to be.used in any area, I certify that use of such fill will-,not. adversely affect adjacent properties. If use of fill is found to adversely affect adjacent-properties, the owner maybe cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If'I am the AGENT FOR THE OWNER, I'promise in good faith to inform the owner of the permitting conditions set forth.in this affidavit poor-to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or..other installations not specifically included in the application. A permit.issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become,invalid, unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a'period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. if work ceases for ninety (90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH yOUR-L-9NO1511 OICA14-Aft6ANEY 691:6111t RECORNN-6 YOUR NOTICE OF COMMENCEMENT; FLORIDA JURAT(F.S.117.03) -OWNER OR AG CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscr d sw&rh'W(draftmed)-before-pe this ------- — I—,- who is/are personally known to me or has/have produced Who We palbe!sonally to me or has/have produced as Identification. as identification. Notary Public Notary Public Commission No. Comm st No. WSW 276 Name of Notary typed,printed or stamped Name of Notary F'&Wregi #GG 12 467 COMMI E ba i2,= E*w Dwftbu toy Fa 803*70 INSTR#2019138517 OR BK 9956 PG 3748 Page 1 of 1 S/H 08/15/2019 12:14 PM Rcpt:2081715 Rec:10.00 DS:0.00 IT:0.00 Nikki AivarezSowles,Esq.,Pasco County Clerk&Comptroller Reintit,Nurtrtier Pmperty*&Numlier r�7�{ �J A I —065_0—nO4S >DG—n-7kL) N'O.T'/C.E OF COMMEWCEME'N' T, State'ofFlorrda r?s4Pr:;.GPEsERvEci FORsx�c�: r�=crr_:_ ar =_nit rz?cra Coutdy".Of QA'rrC d THE UNDERS "NEO Fieretiy gives iptire.that improvements:will'be niad&,to:ceitain Teal properly,atin.in accbrdarrce.vviUi Section913:18 of.tt,e. Floiida S#aGttes,:ftie hitfouiiiiej irttdmtiation'ss provided irYifiisNQiTfEE�ORCOM6lIENGE�ENT. i.Deseription of property(le9gf Lmliebe ,rs � 6j1-7 L� 33 t & 2aaCz OwYY r-t- �.,r l„at�. r— _.• 5'4t3 a Stree#" b)Andress; tggoqral;deseription oflmpiovemenLK; ReplacdMent.Widdow iristalladon, 3:i?wner:Information:orLessee infonnatfon iffhe.tessee;cantracted for.the un rwO. etrt: a j.Nam aril address: k 11 r �1,[Gc•r r.?.r.n 291D _6~5c. CZE 2- g ham_r—L 6.)Name and eddress.of flee"siinp)e 6Behoider{if-different.ttharfowirer_ w- 8s 'above} o:j trrter'est in properly. Owner 4,;ontractortr faunation a.}Name acid address`. Joseph"John Pogash 4(r741-C:ErideavoutWayPiiieitas Faflr;FL 33Z77 ' b.)Teleptione.No,:• (t;sE;j0464tias. PaxNo:;(optional), !:Surety.11fapp.wb!e,:a:copybfUtgpayt mlbortdisathchedj a:i Name•ar d.addtess061 b_j Telephone No.; c:jAriiountof.Banii $ . 6J:ender a)Naive and,Address - b:j-Telepiwne:No.:.. - 7 Person.vrittifn'fhe.Sta6e of F'tot#d4:t1'jlgitiibBdEly Owner upan•w1m?p iurtic or:other doc�mer>fs rrray 6e salved as pinvided'tiy 5ectibii 7`t3.1$;(1},(aj 7:;;F.iarEda Sia�e " Q.Naiite and address: b.)Telepttorre.No: Fax No.;'(6ptional}" 8 a In adclirion'to fiiri eif:orlieiaet�awnet estgriateP of to receive a C60y aft 4'.i6w _ "mrgded inSec6dri.71VX('1).0),Florida:ShaWles. b:j Telephone:tio:: Fax No;'{bptiosrd)j 9�xplratlon`date:af`nopceVf coRrmencementft'e><piration date may:r>attie-before the'iximptetion.af coristiuction and final payinent:to,the corftcty,butvviti)ie-1"v 'r ffot»:ilia date of iecoiding un>ess.a'illfierentchte is:speafied)- WARNING TO.OWNER ANY.PAYMENTS MADE BY THE OWNER AFTEWTHE EXPIRATION OF:THE:NOTICE'OF COMMENCEfdENT ARE CQNSIDERED IMPROPER#AYMENTS UNDEft_;CHApTEft 7'!3„PART 1.SECTION 713.1.3;.FLDRlDA,STATUTES AND CAN RESULT IN•YOUR' PAYINGTtMCE FOR-W)PROVEMENTS•TO YOUR PROPEikT-Yi A IitOTICE"t3F CC111AIkfENCEMENT Mt7ST BE RECORDED AND.POST ii O THE INSPECTION.I :YOU""INTEND TO OBTAIN FINANCING,CONSULTY0UR LENDER OR'AN ATTORNEY BEFORE=MMENCING.WORK OR RECORDW6 Y66R NOTICE OF COMIVIENCEmeNt. Under i'gf perjiuy;i deCtaie thaf)Crave iead,ihe foregoing rwtiix ofdomtnencemerrtand`that ttie'fads stated.ttrereiii'ate tare co:tlie.best,of k wled e z: a '151BnaWieotOwnv .-• 9aee,ar.O•ma'aarlsssee'a.(Au4eataedOmoerlOGaeodpartr�eelManaped (WintNameartrl"PiovideSrgtia{o�/sTiUelOSmj The:foregoiriginstrurrient:wasadinowtedgeclbefore:rtie.this. day of by . tcli5y_ Ail 11 Cjedih :as Owner {two,ofmmpph.gaausme.awmayii1po for self as ' {Nmne'of Person}: {rype alau4tatN."a4 au'stee,sm?ritegm ta1}' for (name oi.paKy on.Deliatf;oiv Aiom:tnsurnent was e�aec�ited). Personally Kmwn Q Produced ID Q Type of ID Dd*s uc&1ri 4 Notary Signature Print NamenN k�, - Notary Public State of Fiodda _. —,- - _._—.--------- ---- — MYCCMMWSI W173196_-- -------_-_-._.�..------- -.- --------- --._� _—_..__._..- - - - - - 4M Expires ot/t)7I20?2 ^ ^ STATE OF FLORIDA,COUNTY OFFAGCO THIS|STO CERTIFY THAT THE FOREG0pQ|GA TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OROF PUBLIC RECORD|N THIS OFFICE WITNESS MYHAND AND FICIALSEALTHIS 44�DAY OF n 2 --'4LER--' BY DEPUTY CLERK DocuSign Envelope ID:09133D638-4241-437E-gDB9-IB75866BBD4A fftdaw and SUding 31 --ific Door Contract aw ew -eei" sftowroom 10741-C Endeavour kAlay FLrontracoes License#SCCT31151663 Location: Pinellas Park, Fl.33777 1.866M1ND.1 89(866-946-3189) units.compiated--windows_Doors Remaining. Name &:M Nome PhoneC7 Address c c 1 Customer(D*, Work Phone FL 'Cell Phone Windows 013tions Series - fllodeW AL Half screen 510 ESP Double Hung -[Up To 114 UX) —Full Screen S22 5000 DH WefdNveld 0$01HP S285 ,Zr Double Loclos i>31Y'rridle) $9 ESP 8000 DH WeldlWeld $401 $260 37 $21 ESP Argon Gas 7700 DHWeIdMeld - 7701 $200 Foam Insulation Wrap S42 u9p 6000&80M Series DH>114 UlAdd S35 DP Rated Glass NIC INC. Other Styles 110odow —Beige orTan or Clay Vinyl Color — S37 Picture Whiftv �4 $329 Wood Grain-Inside Surface $90 2 Lite Slider-(Up To 114 W.) $329 Exterior Color w/Full Screen — $175 x Lite Seder-(i157bi38U.T.) -7'30 V.89 Low-E Elite Glass(App—.21) S65 ESP 2 Lite Slider-(>j3a uj.) S479 lip Tempered Glass Per Sq Ft,ONE Side $6 CasemantlAwning $329 Obscure Glass Sq.FL $6 3 Lite Slider-(Up To 114 Uj.) $520 Tinted-Grey or Bronze Sq.Ft. S6 3 Lite Slider-(i it;To 1-3a u.L) $580 Colonial/Contoured Grids $47 3 Lite Slider-I>i3e wa S670 Oriellcottage Style 60140 $26 310D 16000 Series-Add $40 Scaffolding-PerDay $400 Specialty Wrindows Boom Lift-Per Day $800 Enerm Star Pack-ESP $79 Additional Labor Charcros 2-ulte slider Inrl. >114U.1,Add S40 WndowWodd continues to mainIftm the Good! Remove Steel Window $40" Housekeeping seal of approval,and all our a 3-Lite Slider Inst.Add $80 windows.are Gold label certified, ensuring 4 Installation-Standard 5150 our window systems are of the highest quality. All of our Recess Opening $50 vvindova;have Double Strength Glass and DP rated glass. Install Custom Intl0d Trim $46 PRE 1978 BUILT HOMES(Federal Lead Conlakim�p I Ln nr.,�an Additional Story Charge-Per Floor slo InTheYear kortais; S126 MY Home vviis-Bulft Install Exterior Capping DOORS Bay Window Finish&Trim $300 511 Series Patio Door W-51 il-VO" $950 Header Flashing(Fzeq.-ror Siding) S12 Sit Ser1_-sPaUoDoor6`-5116-6'6' $1,011 Repair Sill OR Jamb Per Ft. $16 511 Series Pella Door W-51fS08' $1,195 Structural Mullion for multi-unit $90 Low-E Elite Glassvy/Argon PerPanal $90 Replace Interior Marble Sill $110 Grids-Pallo 0 oor.Per Panel $60 Replace Exterior Concrete Sill $335 Beige-Palto Doors Per Panel 95 Install Pocket Door $800 61(ding Door Frame Installation $250 Maintenance Agreement - -#of'Aqndows IC15- Panel installation Add-PP $85 8!Tag Panel Installation Add-PP S26S_ ne burarls;responsible for: vmndmv World agrees to install windows and doors -You the buyer may cancel this cornlitelling all HOA andSub as noted aboveand an the attached orderform and to transaction at any time prior to division rules,requirements,and appifoitians, perform otherservices asspecified above forthe price midnight of the third business day 'nemoval andre4astdilaUen ofzny e.Aona security quoted on this form.No other promlss expressed or after the date ofthis transaction. sVstem,baWarbars.AICurrits.xvindoL,covaings,iindfor implied,are rnade excepirthose expressed RT writing Notice of cancellation must be in obstructions prior toinstallation. an this,agreement writing postmarked no laterthan Additional charges for removingitems are atthe following if Window World sealts legal-counsel to enforce midnight of the following third ratimAlCuest.$50,Curtalmlon li/wfndo-.�r romiture- DS slluttm-sso ead obliprionsunderthils contract,Customerazroes; to business day. 111MIAMM" Day reasonable:attorneys fees and costs. 111MALS F_�Lu No extra woric if notin writincif Customer Agrees to the terms of payment as follows: Total List Price$ IL136-7.- Trip Charge and Administrative I Site Setup Fee$100 S Iftoo Site Specific Engineenrigi Fee S 200 8 Fire Marshall Plan Review(St Pete Only)S 125$ sizr-3permit+S 149 AcquisMon Fee$73— Lq7___ Total Amount S _1V CK# Custom Order Deposit 50%37a�U_707 Balance Paid to Installer Upon Completion S _6 wm A e, Amount Financed S CR w. Round Up&Contribute to St.Jude S Loan Approval A J - viSA AN10% WC Disc le Exp.Oate sec.code E /19/2019 67 tom 7/19/2019 Emp.4 -Estimator Date Date VA tl"W-W.170.0:13.T.us dtf.VAM_V7.4 W.1d.1 Md— Owner Date Generalized Building Schematic 20. 12 12 12- 2 N, 14 � 3 BAS01 -( 27 FGR01 2727 27 C{ 7 a t 12 14 28 16 _. 5 FOP01 5 C yQocu 2,!nvelape1D:09B3D638-4241437E-9DB9-1B76866BBD4A ':;; ESP-�:°` -,.!1NlttdfylPH•�`.*{ WRNDOW AND PATIO DOOR ORDER FORM W1u(1a8v WoAd of Tatnpa Day-10741 1lndenvour!%Nay#C Pined us park,H+r,33777 Pa# FAx DATA: r f� Phone: `%313,7 01".6 1-7 G Cris mor Name Phone; Address CityZip Estimator: r -,t Phone: CITY MANt1F MO4EL VINYL WOORN P;,NT MPG SIZE WINDOW HAND GLASS GLASS DP INIP ORIDDPVC143 OBSO TEMP ZONE FULL QFLEL HDR 'CYPE TYPE TYPE 'TYPE 'TYPE COLOR 1Nr EXi —yWIDTH X MIGHT NDMiG(3i HINGE gPTIDN STREGTH REDd GiRGS STYLE PATTERN PULBS4 FULL OSd 4�tyS 6CREEN Dlld FLASH Exley: Tofu Rol ijlO�V9 instal 1Na11 i 70 f 7i a 5 LEL. '1 ?7f� i� LEE ri 11 / 0 v+)+1 x 3&7/4r 7 LEE 30 r�. 1 s4��J:� ti� ✓� x p` !J LLtI's ll 4 i1 s u LEF, to x LEB it x LEE Sz N LEE t3 h L.EE t� x I,Er to u LEE 17 u LEE +o tis x LHE as k LEE I certify the anlespamon has axplalhod and identified mob and every abbrevletion, NQTES: term,and drawing an this pago,to.my Pall and complete understnriding including haw po Cxv_% C,; each and every window is removed,insivilod,trimmod,accessorized,and warranted. l U —DocuSigned by: +l p 7129I2019 --8EIPJ 756F481... DATE mitecopy.6rlginal Yellow copy-Customer PAGE'1 Or__� Flowidu Building Code Online L r�"L� � Pagel of 3 gfissional ° t 9 7701 ,. BCIS Home Log In I User Registration Hot Topics Submit Surcharge I Stats&Facts Publications j Contact Us BCIS Site Map I Links Search Florida �©2 g d00% a Product Approval USER:Public User D 119 L'l:[s Product Approval Menu>Product or Aoplication Search>Application List>Application Detail FL# FL15819-R10 Application Type Revision Code Version 2017 Application Status Approved t i Comments Archived ❑ Product Manufacturer Wincore Window Company,LLC Address/Phone/Email 250 Staunton Avenue Parkersburg,WV 26104 i (304)485-7460 Ext 228 mreed@wincorewindows.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Mike Reed ALL WORK SHALL COMPLY WITH PREVAILING Address/Phone/Email 250 Staunton T ePODES FLORIDA BUILDING CODE, Parkersburg,WVV 261 2630 I (304)485-7460 Ext 2NATIONAL ELECTRIC CODE, mreed@wincorewindo"rdUTHE CITY OF ZEPHYRHILLS 2019 Quality Assurance Representative Mike Reed ORDINANCES ss? a 3 Address/Phone/Email 250 Staunton Turnpike REVIEW DATE Parkersburg,WV 26104 (304)485-7460 Ext 228 CITY OF ZEPHYRHILL mreed@wincorewindows.com PLAN EXAMINER Category Windows Subcategory Double Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan].King,P.E. G Validation Checklist-Hardcopy Received Certificate of Independence FI-15819 R10 COI (b)Certificate of Independence.Ddf Referenced Standard and Year(of Standard) Standard Year AAMA/W DMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2005 'ASTM E 1300 2004 _ ASTM E1886 2005 ASTM E1996 2006 TAS 201,202,203 1994 Equivalence of Product Standards Certified By I https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquegl%2bT71%2fF1... 5/18/2019 Florida Building Code Online Page 2 of 3 f; Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/20/2019 Date Validated 02/20/2019 Date Pending FBC Approval 03/01/2019 Date Approved 04/16/2019 summary of Products FL# Model,Number or Name Description 15819.1 a.8400 Series Vinyl Double Hung Extruded PVC Double Hung Window with"Non-Impact" Window Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 R10 II (b)Inst 15819.1.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.1 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.1.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.2 b.8800 Series Vinyl Double Hung Extruded PVC Double Hung Window with"Impact"Insulated Window Glass Limits of Use Installation Instructions i Approved for use in HVHZ:No FL15819 RIO II (b)Inst 15819.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.2 for Design Pressure Ratings,any FL15819 R10 AE (b)Eva] 15819.2.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. I 15819.3 c.8800 Series"HVHZ"Vinyl Double Extruded PVC Double Hung Window with"Impact"Insulated Hung Window Glass Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15819 RIO II (c)Inst 15819.3.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.3 for Design Pressure Ratings,any FL15819 R10 AE (b)Eva[15819.3.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.4 d.400 Series Vinyl Double Hung Extruded PVC Double Hung Window with Nailing Fin-"Non- Window Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 RIO II (a)Inst 15819.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.4 for Design Pressure Ratings,any FL15819 RIO AE (a)Eva] 15819.4.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.5 e.500 Series Vinyl Double Hung Extruded PVC Double Hung Window with Nailing Fin and Window Integral"T'Channel-"Non-Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 R10 II (a)Inst 15819.5.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.5 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.S.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15819.6 f.5400/5400S Series Vinyl Double Extruded PVC Double Hung Window with"Non-Impact" Hung Window Insulated Glass(Double Strength Glass with Reinforced Sash) ((( Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 R10 II (a)Inst 15819.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 I( f htt s://floridabuildin .or / r/ r a dtl.as x? aram=wGEVX wtl� ue 1%2bT71%2fF1... 5/18/2019 P g g P p 1�P_ P P Q q q I Florida Building Code Online Page 3 of 3 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.6 for Design Pressure Ratings,any FL15819 R10 AE (a)Eva] 15819.6.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.7 g.5400/5400S Series Vinyl Double Extruded PVC Double Hung Window with"Non-Impact" Hung Window Insulated Glass(Single Strength Glass with non-reinforced Sash) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 RIO II (a)Inst 15819.7.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.7 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.7.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15819.8 h.7700/9000 Series Vinyl Double Extruded PVC Double Hung Window with"Non-Impact" Hung Window Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 RIO II (a)Inst 15819.8.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.8 for Design Pressure Ratings,any FL15819 R10 AE (a)Eva] 15819.8.1)df I additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. { 15819.9 1.7700/9000 Series Vinyl Double Extruded PVC Double Hung Window(Reinforced Sash)with IJ Hung Window "Non-Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15819 R10 II (a)Inst 15819.9.Ddf 1 Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 i Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15819.9 for Design Pressure Ratings,any FL15819 R10 AE (a)Eval 15819.9.Ddf i additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1874 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts. .1 ap eChxk Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquegl%2bT71%2fF 1... 5/18/2019 f R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry JL7 C P.O.Boa 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 B B � �BP D / i i Product Sub Category Manufacturer Product Name Category Wincore Window Company,LLC. 1700 19000 Series Windows Double Hung 260 Staunton Turnpike Vinyl Double Hung Parkersburg,WV 26104 Window "Non-Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID# 1998)for Wincore Window Company, LLC. based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations. 1 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. I 3. When used in areas requiring wind borne debris protection this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2&R301.2.1.2. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15819.8 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15819.8 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02801070 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright TEL 02801071 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright 2. Drawing No. Prepared by Signed&Sealed by No.FL-15819.8 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. ' 3. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. 4. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute,certifying that Wincore Window Company, LLC.is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. f� � !'•j''i t n /V 4 .4 {j`l`.N.tip� A ny 1>1 C ...`T .s. O �. it `"�'{...`'�•�- V 4�U�tit�i}SULVC� Lyndon F.Schmidt,P.E. FL PE No.43409 7/19/2017 Sheet 1 of 1 I t I 52"MAX FRAME WIDTH :0`�`, k4�� 'MAX D.L.O.WIDTH1. O�'° •''�'��: rn 250 Staunton Turnpike,Parkersburg,WV 26104 4�•e '"" •S`yNN >>° D rn p�� ranee 0 N fO z 7700 9900 Series X a 0 X Z< E a ?03 0 o a Vinyl Double Hung 6 E oZ Window _ � �w 310. "NON-iMfAC ' X w xCq w3 �¢ GENERAL NOTES ;-d Uj Op Q Ja' 1. This product has been evaluated and is in compliance with the 6th / Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). a a 2. Product anchors shall be as listed and spaced as shown on details. 12 m Anchor embedment to base material shall be beyond wall dressing Max.':,.,;: •Max: '; DEslcra rRes'suae,�Psq,.;:' rrdaz ti:', a ,:•MAJf:,,'.;1:'s;- DesrGNpeFssoaE(PSFj m m or stucco. Glass Glass. FRAME, D.LO:, ... FRAME',; ,'D'1-O 4 c 'r`._DIMENSION q'. DIMENSION. -TYPE POSITIVE NEGATNF_ ',!DIMENSION DIMENSION „ ;rcPE.;,5'�;,POSRIVE� `NEGATIVEf. y = 3. When used in areas requiring wind bome debris protection this 32.0"X58.0" 25.0^X24.75" G1,G2 +55.0 .55.0 36.0"X64.0" 29.0^x27.75^ G1,G2 +40.0r-40.0 N N product is required to be protected with an impact resistant covering U, g that complies with FBC Sections 1609.1.2&R301.2.1.2. 52.0"x 4a.o" 4so^x 15.75^ Gt,G2 +45.0 -45.0 32.0"x70.0" 25.0"x 30.75" G1,Ga +40.0 w w z o 4. For 2x stud framing construction,anchoring of these units shall bethe 43.0^x42.0" 41.o^X16.75" G1,G2 +45.0 45.0 52.0^x50.0" 45.0^x20.75^ G1,G2 +35,0! same as that shown for 2x buck masonry construction. 44.0^X46.0" 37.0"X 18.75' G1,G2 +45.0 .45.0 48.0"X54.0" 41.0"X22.75" G1,G2 +35.0 o z y «Q� 5. Site conditions that deviate from the details of this drawing require 4o.o"x52.o 33.0"X21.75 G1,Gz +45.0 -45.0 44.0"X60.9^ 37.0"x25.75" G1,G2 +35.0 -35.0 a a d further engineering analysis bya licensed engineer orregistered 36.0"X56.o" 29.o"x23.7s" G1,G2 +45.0 -45.0 40.0"X66.0" 33.0^X29.75^ Gt,Gz +35.0 35.D Dom` a architect, o o N N Q F 32.0"X 64.0" 25.0"X 27.75" G1,G2 +45.0 45.0 36.0"X 72.0" 29.0"X 31.75" G1,G2 +35.0 .35.0 v TABLE OF CONTENTS z 52.0"X44.W 45.0"X17.75" G1,G2 +40.0 -40.0 52.0"X60.0" 45.VX25.75" G1,G2 +30.0 -30.0 a n N Z a SHEEN DESCRIPTION d 1 Typical elevations,design pressures and general notes 48.0"X 48.0" 41.0"X 19.75" Gt,G2 +40.0 -40.0 48.0"X 64.0" 41.0X 27.75" G1,G2 +30.0 -30.0 0A 6/23/t 4 2 Horizontal cross sections srm,c• N.T.S. 3 Verfical cross sections 44.0"X52.0" 37.0"X21.75" G1,G2 +40.0 -40.0 L12. 7'21' 37.0"X30.75" G1.G2 +30.0 -30.0 DWG.BY.. JK m 4 Buck and frame ,componen 40.0"X58.0" 33.0"X24.75" G1,G2 +40.0 .40.0 33.0"X31.75^ G1,G2 +30.0 -30.0 CHK.BY; LFS 3 0 ng 5 Bill of materials,components&glazing detailsGRMING No.-. 45.0"X31.75" G1,G2 +25.0 -25.0 FL-15819.8 d y o G SHEEr_L OF 5 z RAClientAWincore PERMANENT\A-Florida Product Appro4s\FL-15819 Double HU1191C-Dralving$\CurrentkfL-15819.8.dwg,.25 CCt 0 0 -n cr m vy ;a M NW Imp a. rs At!. 09 'A I Ix 102 O 17-1 0 jz M C=30� 42 nt M EM a "fill, ..43409 7/7 —PRODUCT: Uo.arn-t.FMp..d er-wa ORMS-.0" 6 01 17 UPDATE To 7700 9900 SERIES Lyndon F. Schmidt . ........... cy, 4 6TH ED. (201?) FBC. LFS Vinyl Double Hung Window P.E. No. 4,3409 raj ALI-0 —6 REVISE INSTALLA770M SCREWS LFS'Z31 *3 lrtt OVAL %% 2 UPDATE TO 5TH ED. (2014) FBC LFS PART OR ASSEMBLY: 1 8/25/14 HEvisE 1 27�1 75 BUILDING CONSULTANTS, NO. DATE HORIZONTAL OR-U(p'.1. Box 230, Valrico, FL 33595 11 SERIES N0. JK REVISIONS BY CROSS SECTIONS Phono No.: 813.659.9197 FBPE C.A. No. 9813 14 R.W.B—DING C..S—S INC. - i R'\Clients\Wincore PERMANENT\A-Florida Product Approvals\PL-15819 Double Hung\C-Drawings\Current\FL-15819.8.dwg,35 a m N W m V A 0. 10 w wd a N r O M 0 0 �O 0 d Z � N N m n 1-1/4°MIN. A EMB.[fYP.) r— O n m p a' n E W N V 0 0 ,m o � o 00. 1-1/4'MIN. m EMB.pyp.) 0 I I m m� O$rn D �' a)n n O m o 0 O �CA CA 0 0 a N N o No.43409 ' 7(9'7 o a E g PRODUCT: Documento Prepared Dy: BMW OF is " r 7700/ 9900 SERIES Lyndon F. Schmidt I-, �ORiO�,•. '��� 4 6 01/77 UPDATE TO 6TH ED. 2017 FBC LFS P.E No. 43409 •• " IW �, o z w 3 5 10116 REVISE INSTALLATION SCREWS �g Vinyl Double Hung Window !(i'st@t;%% y LI 2 1 27 UPDATE TO 57H ED. 2014 FHC LF5 PART OR ASSEMBLY: BUILDING CONSULTANTS, I�C. I� c0 in 1 18/25/154 REVISE SERIES NO. JK VERTICAL W p.0. Box 230. Voldco, FL 33595bD 1; NO DATE BY CROSS SECTIONS Phone No.: 813.659.9197 REVISIONS I FBPE CA. No. 9813 - m2014 R.W.SUILCINC CONSULTANTS INC. .......... W ICMA)L O.C. VYP-) ...... its% C; 0 -M 0 xz*-� o w 0 CL dam 01 M ! C�7 2X Ix IXBUCK D 2X BUCK J BUCK—,� to TYP. DIRECT TO BUCK G MASONRY TV. —LrL FRAME--,,, — FRAME OPENING MASONRY OPENING MASONRY IXBUCK DIRECT MASONRY OPENING MA`ONRY—� in CS to m OUCKANCHORING FRAME ANCHORING FRAME ANCHORING 2X Buck IXBuck Direct to masonry T, Vu V) z CONCRETE ANCHOR NOTES. 1.Concrete anchor locatlam at the comers may be adjusted to maintain the min. edge distance to mortarloirtfs. 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to OL maintain the min.edge distance to mortarjoints,additional concrete anchors M may be required to ensure the'MAY-ON C24W dimensions are not exceeded. 3.Concrete anchor table., ................. .......................... % XAM :z' ............... ............... ti g6ik ....... U........... ITW 6123114 Z, TAPCON0 sr N.T.S. ELCO JK ULTRACON 47 WOOD SCREW INSTALLATION NOTES.* LFS 1.Maintain a minimum$/8"edge distance,I"end distance,&I"ox.spacing of FL-15819.6 wood screws to prevent the splitting of wood. ISHEET-4 OF 5 BILL.OF MATERIALS . ............ T IIEM 9 DISCIUMON MATERIAL A I X BUCK SG>=0.42 WOOD B 2X BUCK SG>=0.42 WOOD— DIV cs N. Lo 4� � S coks A B C IX MAX.SHIM SPACE D go E )A' D 1XX 2-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL A, so MASONRY-3,000 PSI MIN,CONCRETE CONFORMING TO Aff— ....... •0 E CONCRETE LOW BLOCK CONFORMING TO ASTM C90 C3 0 z c;;j 0.071, 301 0 HOL lilM ♦ 8" 0'4 F V8 X 2 FAR HEAD[rRUSS HEAD WOOD SCREW(1-3/8'MIN.EMBEDMENT) STEEL G 114'X 2-1/4'PFH ELCO OR ITW CONCRETE SCREW STEEL ra mo I FRAME JAMB-(DH 7701) PVC 02.e 2 SILL'(DH 7703) PVC 2z 0.71" 3 FRAME HEAD'(DH 7701) PVC 4 UPPER SASH STILL --�. (SE 3035) PVC I T S op ASO SNLF oz5 LOWER SASH STILE-(SE 3045) PVC as 6 GLAZING BEAD* PVC 7 KEEPER RAIL UPPER SASH'(SE 3034) PVC 1.9 1.42' 7 LOCK RAIL LOWER SASH*(SE 3046) PVC c!f, 11 TOP RAIL UPPER SASH-(SE 3037) PVC !3 12 BOTTOM RAIL LOWER SASH'(SE 3047) PVC C3 16 WEATHERSTRIP ULTRA FAB.270 FILE-270-1875B c, C3 Js 17 WEATHERSTRIP SILLBULB(AMESBURY 32690) cau- o 19 HEAD ADAPTERw(DH 3005) PVC ::i 20 LOCK 8513/8845 LAWRENCE PVC GLAZING HAD KEEPER RAIL R SASH SME ti , 21 KEEPER 2700-214 LAWRENCE PVC \.n/Bottom kL./uppersash o R 22 #8 X I"PFH(VINYL LOCK SCREWS-) STEEL m 23 #6X 1-1/2'PFH(VINYL LOCK SCREWS} STEEL —W-1 Y SASH TILT LATCH-ASHLAND PVC 1.6e 2 1 Ig,c� 28 PIVOT BAR-CALDWELL 29 1#8 X I/2'SELF TAPPING PPH Sms STEEL Lf 0,07. 9THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARETO BE PRODUCED BY F V) En R& EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". C2- b qg u — —.4 ia V) LOCK RAIL -TOP RAIL 8 0—'T0m—W L 09LowerSosh 11@u"Upper 12&Lo.er h En 1/2'GLASS BITE 1J2'GLASS BITE 2; r— GLAZINGTAPE j�j\ 7,188"T,,,HICK GLASS GLAZING TAPE 7/191"THICK GLASS 0.41"--1 &0 1 1/87 ANNEALED L 0 1/8*ANNEALED 3=0 z 0.0W'SctQeX*PVB INTERLAYER Ir a I/WANNEALED I I AIRSPACE DAM 6 14 z 1/8'ANNEALED 0 0 to z I/WANNEALED 01T C3 SCALe N.T.S. < No.ff(. INTERCEPT SPACER INTERCEPTSPACER Or-Br LFS GLAZING DETAIL @-E(See 111TAIL Genera! M.J� Ttel Sheet l) ISee Geneml Note 3.Sheet 1) (See Gen"ca h G2 OEW BL Z— sHEEt 5 of Florida Building Code Online t'Lljlv Ai- Page 1 of 5 Regfilatitih 0A Mho BCIS Home Log In User Registration Hot Topic Submit Surcharge Stats B Facts Publications Contact Us BCIS Site Map { Links Search db a d2 / g �i r �I Product Approval � D USER:Public User Product Aoormal Menu>Product or Application Search>Application List>Application Detail FL# FL16092-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Wincore Window Company,LLC Address/Phone/Email 250 Staunton Avenue Parkersburg,WV 26104 (304)485-7460 Ext 228 mreed@wincorewindows.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Mike Reed Address/Phone/Email 250 Staunton Turnpike Parkersburg,WV 26104 (304)485-7460 Ext228 mreed@wincorewindows.com Quality Assurance Representative Mike Reed ALL WORK SHALL COMPLY WITH PREVAILING Address/Phone/Email 250 Staunton Turnpike CODES FLORIDA BUILDING CODE, Parkersburg,WV 26104 NATIONAL ELECTRIC CODE, (304)485-7460 Ext 228 mreed@wincorewindows. D THE CITY OF ZEPHYRHILLS ORDINANCES Category Windows Subcategory Horizontal Slider p��� 1 p Compliance Method Evaluation Report from a Florida B�tt�r 4 eh L4�ns Florida Professional Engineer RR��.VV.er/n— 1 ❑ Evaluation Report-Hardcoq�eFc�vl) �' Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J.Ong,P.E. CAI Validation Checklist-Hardcopy Received Certificate of Independence FL16092 R6 COI (b)Certificate of Indeoendence.odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E 1300 2004 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By 1httnc•//flnritlah1ii1dina nrcr/nr/nr ann df] aeny9naram=w('TFXTYC),tvtT)ntFPrndVi7,,.TTIWnxrvfn S/152/�111 Q y 4 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/20/2019 Date Validated 02/20/2019 Date Pending FBC Approval 03/01/2019 Date Approved 04/16/2019 Summary of Products FL# Model,Number or Name Description 16092.1 a.8400 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with"Non-Impact" Sliding Window Insulated Glass(XX,OX or XO Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.1.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.1 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.1.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.2 b.8400 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with"Non- Sliding Window Impact"Insulated Glass(XXX or XOX 1/4-1/2-1/4 Configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16092 R6 II (a)Inst 16092.2.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.2 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.2.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.3 c.8400 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with"Non- Sliding Window Impact'Insulated Glass(XXX or XOX 1/3-1/3-1/3 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.3.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.3 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.3.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 16092.4 d.8800 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with"Impact" Sliding Window Insulated Glass()(X,OX or XO Configurations) Limits of use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (b)Inst 16092.4.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.4 for Design Pressure Ratings,any FL16092 R6 AE (b)Eval 16092.4.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 16092.5 e.8800 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with Sliding Window "Impact"Insulated Glass()=or XOX 1/4-1/2-1/4 Configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16092 R6 II (b)Inst 16092.5.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.5 for Design Pressure Ratings,any FL16092 R6 AE (b)Eval 16092.5.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.6 f.8800 Series Vinyl Horizontal Sliding Window https://floridabuilding.org/pr/pr_apv dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWrwxfo... 5/18/2019 Florida Building Code Online Page 3 of 5 Y Extruded PVC Endvent Horizontal Sliding Window with "Impact"Insulated Glass(XXX or XOX 1/3-1/3-1/3 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (b)Inst 16092.6.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.6 for Design Pressure Ratings,any FL16092 R6 AE (b)Eval 16092.6.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.7 g.8800 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with"Impact" Sliding Window Insulated Glass(XX,OX or XO Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16092 R6 II (c)Inst 16092.7.odf Approved for use outside HVHZ:Yes Verifed By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.7 for Design Pressure Ratings,any FL16092 R6 AE (c)Eval 16092.7.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.8 h.8800 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with Sliding Window "Impact"Insulated Glass(XXX or XOX 1/4-1/2-1/4 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16092 R6 iI (c)Inst 16092.8.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.8 for Design Pressure Ratings,any FL16092 R6 AE (c)Eval 16092.8.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.9 1.7700/9900 Series Vinyl Extruded PVC Horizontal Sliding Window with"Non-Impact" Horizontal Sliding Window Insulated Glass(XX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.9.odF Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.9 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.9.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.10 j.7700/9900 Series Vinyl Extruded PVC Endvent Horizontal Sliding Window with"Non- Horizontal Sliding Window Impact"Insulated Glass(XOX 1/4-1/2-1/4 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.10.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.10 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092,10.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16092.11 k.7700 19900 Series Vinyl Extruded PVC Endvent Horizontal Sliding Window with"Non- Horizontal Sliding Window Impact"Insulated Glass(XOX 1/3-1/3-1/3 Configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16092 R6 II (a)Inst 16092.11.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.11 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.11.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.12 I.400 Series Vinyl Horizontal Sliding Extruded PVC Horizontal Sliding Window with Nailing Fin- Window "Non-Impact"Insulated Glass(XX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.12.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.12 for Design Pressure Ratings,any FL16092 R6 AE (aa)Eval 16092.12.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. httns://floridahuilding-org/nr/nr ann dtl_a-,nx?naram=wCrF.VXnwtT)ntFPm(iViNT)Wnxnrfn S/1 R/?n10 Florida Building Code Online Page 4 of 5 160R2.13 m.400 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with Nailing Sliding Window Fin-"Non-Impact"Insulated Glass(XOX 1/4-1/2-1/4 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 I1 (a)Inst 16092.13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.13 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.13.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.14 n.400 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with Nailing Sliding Window Fin-"Non-Impact"Insulated Glass(XOX 1/3-1/3-1/3 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.14.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.14 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.14.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.15 o.500 Series Vinyl Horizontal Extruded PVC Horizontal Sliding Window with Nailing Fin/ Sliding Window Integral J Channel-"Non-Impact"Insulated Glass(XX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.15.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant.No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.15 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.15.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.16 p.500 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with Nailing Sliding Window Fin/Integral J Channel-"Non-Impact"Insulated Glass(XOX 1/4-1/2-1/4 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.16pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.16 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.16.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.17 q.500 Series Vinyl Horizontal Extruded PVC Endvent Horizontal Sliding Window with Nailing Sliding Window Fin/Integral J Channel-"Non-Impact"Insulated Glass(XOX 1/3-1/3-1/3 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092 17 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure.,N/A Evaluation Reports Other:See INSf 16092.17 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16O92.17.r)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.18 r.5400/5400S Series Vinyl Extruded PVC Horizontal Sliding Window-"Non-Impact" Horizontal Sliding Window Insulated Glass(XX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.18.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.18 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.18.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16092.19 s.5400/5400S Series Vinyl Extruded PVC Endvent Horizontal Sliding Window-"Non- Horizontal Sliding Window Impact"Insulated Glass(XOX 1/4-1/2-1/4 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.19.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.19 for Design Pressure Ratings,any FL16092 R6 AE (a)Eval 16092.19.odf Created by Independent Third Party:Yes bttns://floiidabuilding.org/nr/nr ann dtl.acnx?naram=vC'TF.VXOwtl)ntFPmriY;NT)Wrwxfn 5/1 R/Mi A Florida Building Code Online Page 5 of 5 i+ additional use limitations,installation instructions and product particulars. 16092.20 t.5400/5400S Series Vinyl Extruded PVC Endvent Horizontal Sliding Window-"Non- Horizontal Sliding Window Impact"Insulated Glass(XOX 1/3-1/3-1/3 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16092 R6 II (a)Inst 16092.20.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16092.20 for Design Pressure Ratings,any FL16092 R6 AE (a)Eva] 16092.20.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AAJEEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe httnc•//flnrir1ahiii1dinor nrcr/nr/nr ann tit] 0 R R W Building Consultants, Inc. WB Consulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board ofProfessional Engineers Certificate ofAuthorization No.9813 Pe6dud EvaluationRepod I?ep o i-t No. A-16092.9 Da�e�. Al 202017 Product Sub Category Manufacturer Product Name Category Vifincore Window Company,LLC. 7700 19900 Series Windows Horizontal Slider 250 Staunton Turnpike Vinyl Horizontal Sliding Ifflinclow Parkersburg,WV 26104 "Non-Impact!, Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.(System ID# 1998)for Wincore Window Company,LLC.based on Rule Chapter No.61 G20=3,Method I D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 11. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements excluding the nHigh Velocity Hurricane Zond'(HVHZ). 2, Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne d'debris protection this product is reqUired to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2&R301.2.1.2. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-16092.9 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-16092.9 for size and design pressure limitations. Supporting DocOments. 1. Test Report No. Test Standard Testing Laboratory Signed by ATI C7032.02-501-47 AAMANVDMA(I0I/I.S.2/A440-08 Architectural Testing,Inc. Lynn George 2. Drawing No., Prepared by Signed&Sealed by No.FL-16092.9 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt P.E. 3. Calculations Prepared by Signed&Sealed b Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Quality Assurance Certificate of Pa'rticipation issued by National Accreditation and Management Institute,certifying that Wincore Window Company,LLC.is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. S T, fj Lyndon F.Schmidt,P.E. Fl.PE No.43409 7J20/2017 Sheet 1 of 1 ti 12 W 9G'MAX O.A.FRAME WIDTH WINDOQiTS&DOORS '•�'>,� l"2 250 Staunton Tumpike,Patkersbur&WV 26104 D.L O.WIDTH yp ate•• Em -pmm 0 IL Ia 7700/9900 Series B 9. Vinyl Horizontal Sliding Window " ON-iMPACT' s z = to Z GENERAL NOTES w i. This product has been evaluated and is in compliance with the 6th a I w Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 1 r �,m 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing t orstucco. ' h t v N N e 3. When used In areas requiring wind bome debris protection this v, product is required to be protected with an impact resistant covering o_ i that complies with FBC Sections 1609,1.2&R301.2.1,2. _ _ -_- e>' $ the FPAME'e?;?;,•'S_ :r=ib:LOi :'s;';% _ u r 4. For 2x stud framing construction,anchoring of those units shall be _.�:.,,., -- N - _ POSRf1!8; NEA7lYE? .3 same as that shown for 2x buck masonry construction. .,,;.F,.1t4tt:NSlt7N--'=:;"BfME_5lQ,,,i= `_•s::,;..::•--_'-:,.•:....:........,:._,. ,...:•: a 5. Site conditions that deviate from the details of this drawing require 96.0"X 72.0" 43.5"X 64.0" G1 +15.0 -15.0 5 °a_ further engineering analysis by a licensed engineer or registered h=' architect. 74.0"X 63.0" 32.5"X 55.0" 01 +30.0 -30.0 N a Melevations, ABLE OF CONTENTS 84A"X 54.0" 37.5"X 46.0" G1 +35.0 -35.0 z N` Z o SHEENDESCRIPTION levations,design pressures and general notes 72.0"X 48.0" 31.5"X 40.0" G1 +45.0 -45.0 DAM 4 25 13 al cross sectionssr N.?.5. cross sections CAMB. JK m d ame anchoring(Mox.Frame Size:96"x 72") ON X 44.0" 27.0"X 36,0" e1 +50.0 -5$.0d frame anc oring Max.Frame S e:72"x 48° exx W. LFS o2nwwo 9oa Y 6 Bill of materials,components&glazing eta0s rn FL-16082.9 0 n s"Err_L or 6 6 a FL%cuants\N6nmre PERMANU47NA-Florida Product ApprovalAR-16092 Horizontal 4ider%C-DrawingslCunentXFL-160929-10Xlwg,21 O �W W N N Z go �O az lulln�- f7 \• n ❑n m W W 0 I0 0 A •O 120: y n m o p _ N ch o P T n 0 z o N A O m x _ O Aa X� E3 Dpq O � tr El ❑ z - •4 �o � 0 36 m O r0 •CD Tr0 fm1 w a.0 8 Z ❑ ❑ In a� o oa G 0 z� N C $CH16jjQAi��i Na 43409 �'0 yv x A q oaf' PRODUCT: Dowmelda praparad By!i g�UEpp r'I- z F• 7700/9900 SERIES Lyndon F. Schmidt P.E ��i��''••,!tZORl01;,.•'� �� 1 •a No. 43409 /77I'�QU����`�� ,o^ `' r, y CNi1 2 6 O7 17 UPDATE TO 6TH E. 2017 F13C LFS PART DR ASSEMBLY: @ BUILDING CONSULTANiS.II(b�t`` Im tv to 1 1128115 UPDATE TO STH E0. 2014 F8C JK P.O. Box 230,VDlrico, FL 33595 io w NO DATE 8Y HORIZONTAL Phone No.: 813.869.9197 REVISIONS CROSS SECTIONS FBPE C.A. No. 9813 02013 R.W.SUILDIND OCNSULTA INC. Kkaents\tMnmre PERMANENAA-Florida Product Approva6\R.-16092 Horizontal Slider\C-Drawings\Cum=.ngFL-160929.1DAva 31 sa w A a v m m O w a tr 22 W la a Q o o Q� a �r o� �0 0 0 o 0 N m O ❑0 to 5 1-1/4'MIN. 1-T/4'MIN. c Q EMB.(TYP.) - ia K m 91 to $m m m o m a a w n a m m n w a � . W W ^ la W N o� o o Qn o 0 S M rA 1-1/4°MIN. ea.pp.) `�� \F•SCHAlj� ^i 4 Na 43409 ' i gI PRODUCT: Doarmonb Fmparbd Sy!i SdREOF 1 7700/9900 SERIES Lyndon F. Sch-Id! A • tw P.E. No. 43409 �It' z N / •o^ N r L -i 2 6 07 77 UPDATE TO 6TH ED. 2017 FBC LFS PART OR ASSEMBLY: BUILDING CONSULTANTS,IIIV�1` Im U1 1 i 26 15 UPDATE TO MR ED. 2014 Ft3C JK r� P.O. Box 230..VDlrieo. FL 33595 ICAL NO DATE BY CROSSRSEC77ONS Phone No.: 813.659.9197 REVISIONS FBPE CA No. 9813 ®2D13 R.W.9UILDIN13 N DD9ULTANTB INC. r 401 •• • � ,� R '' i * sw �,. '� '6 of ro MASONRY 'I ...• T OPENING Iltt ^!k V%% z o (TYP•I d S ttl ttlttt z z ma-IL lac III(II Z (tL)IRECTTO D SUCK 2X fryP4 FRAME RUCK T, e MASONRY �z I I m OPENING (TYP.HEAD&JAMBS) 2X BUCK w N L3 x i I of L9 . T II �. !n fe BUCKANCHORiNG FRAMEANCHORING ^a ao MAX.FRAME SIZE: 96"X 72" w w V, oS CONCRETE ANCHOR NOTES: g 1.Concrefo onchorlocatlons at the comers maybe adjusted to maintain the min. �+ a edge dfstanee to morfarJolnfs. ,� 2 Concrete anchorlocations noted as MAX.ON CENTW must be acyusted to 9 a i maintain fhe min.edge distance to mortorp*ds,additional concrete anchors may be required to ensure the MAX.ON CENTWdimension are not exceeded. ti g S.Concrete anchor table: o+ a A o 0 }r 111tAN C'^,....:.....__..re:•:::._...^_:..:.........:•.::. {k:�aJa��:;Fi%:;i:j!:,if;:L�tf�:[':{{ O^`=lYit,.�,F�fi.3'cam iiii'r%i :'.3iiiii7:iN3 ii'J.:�iii:{••. .:..... 1.114" r 4 :.:::::::..:::.::.:.::::..:::::.:..-::.-::::.-:::::.�:::::•:.-:.::•::::�:::�::�:::::::::::irL1�,tX.::.-:.-:•::.:.,�:::.-:::Ahti�ltbfii�ii "'^z n° ITW 4 25 13 ? TAPCON ® 1/4" " sauce N.T.S. LCO ULTRA ONO 1/4' 1.1/4" i" 4' M.oft JK a WOODSCREWINSTALLATIONNOTES: cHR,BY: LFS 3 ;1 1.Mainfuln a minimum,518"edge distance,l"end d4tonce,a i"o c.spacing of FnAwl ',iir : wood screws to prevent the splitting ofwood. FL-16092.9 0 stW 4 or 6 xi q u), i V'•. �N uMASONRY oiq MASONRY �i�••°••. .. . ��� >°'mo m OPENING 2 OPENING '''�r�r/4r I1111 ��```` Z O m z° QCW a a� �d. D � }�• I I _ � 5 p�_ 2)( ) I I G 2XBUCK Pn $ Jzy BUCK FRAME i D 1XBUCK 2XBUCK — II DIRECTTO •- �a MASONRY o x I(TYP.HEAD&JAMBS) ZN 1 W n rn m `• •a.. 6• �.• C BUCKANCHORING FRAMEANCHORING a a 0 z MAX.FRAME SIZE: 7T X 487 N N n s �8 0 En £ CONCRETE ANCHOR NOTES: 00 1.Concrete anchorlocations a/the comers maybe adjusted to maintain the min. k'f edge distance to mortar joints. ¢o a 2 Concrete anchorlocallons noted as MAX.ON CENTER"must be adjusted to >> i maintain the min.edge distance to mortarjoints,additional concrete anchors n H may be required to ensure the MAX.ON CENTER"dimension are not exceeded. ^ r va Concrete anchor table: o a¢O •o :''';N1'� 0.```s:iN:.:-S-:::.•l::.�Z:::•:::D:•:::i::•:::;:::;.;:�G::.;.M:.:,.:::.N:::,6:.):;u. :N.:.I:.':.:;::. z :..! :I� � 4 25113 E ® 1/4° 1.1/4" 2" 4" 7APCON sQ•,". N.T.S.ELCO 9 ULTRACON® 1/4" 1.1/4" 1" 4' o + JK mm cm M LFS 3 WOOD SCREW INSTALLATION NOTES: ANG NMI d c 1.Maintain a minimum 5/8" MA edge distance 1"end distance,&1"o.c.spacing of FL-16092.9 cs wood screws to prevent the spriUing of woad. N c sHm 5 or 6 d BILL OF MATERIALS NM 0 DESCRIPDON MATERIAL QNC�•••• ���'� m A i X BUCK(SG>=0.42) WOOD 3'9� B 2XBUCK SG>=9.42� WOOD ?; I C 1/4"MAX.SHIM SPACE - �' �tA; ri O1 D 1/4"X 2.9/4"PFH ELCO OR QYV CONCRETE SCREW STEEL �� MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI L s- ''•,.,• E CONCRETE 'e§r Z �G� ..• ���• w> ° 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 O 0 G #8 X 2'PFH WOOD SCREW(1-7/16"MIN.EMBEDMENT) STEEL AF36(1-1/2"Brick Mould) ,��.11 *L�� ��� J 1/4"X 2-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL v zezo1 FRAME' PVC \ ` i 9 0`o a2 SUDER PULL STILE' PVC CD \ m 3 LOCK STILE' PVCL.0:65q v I� '� 4 KEEPER STILE° PVC PsaMe " II c r r J. . 0 $z 5 GLAZING BEAD* PVC �— � hl� I ZI d i(' 510 6 SLIDER COMMON RAIL' PVC 4c g� 7 METAL ROLLERS W/PLASTIC HOUSING ; 8 WEATHERSTRIP(0.230') _ L_--�� 9 WEATHERSTRIP(0.389') L) o a 11 SILL TRACK ALUM o 1) 16 REINFORCEMENT(LOCK&MEETING STILE (CS TYPE B HOT DIPPED GALV.) AFS9 Masonry Flange V672(Masonry Flange 2) m z °� •THE APPROVED WHITE RIGID PVC EXIETIK)R EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY y ^� g EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS°. OPTIONAL COSMETIC FLANGES oo d 5�cq 2.04" 4 1 g. 0 0 6 0 0.07" 0.07' [� I m R v a O.OT' ci o IL N N SUDER PULLSDIE 1ACKSIIIEpER yn� z a GLAZINGTAPE 1/Y'GLASS BY LAMATEK BITE 7/8'THICKGLASS o 0 O 0 1/WANNEALED 0 0.73 _ o 0 11 w C Ti; ,..�J� o N Q m o _ Q AIR SPACE o 0 1/8'ANNEALED o DACE; 4 25 13 i Z 0.88' 1.4 scvE N.T.S. mvo. m INTERCEPT SPACER ft JK5 GLATlNGBEAD 6 SIIDERCOMMONRAIL 11 SILL CK 16 REINFORCEMENT CHK Bn LF8 ; Gl GLAiINGDETAII Io�c8MemlingSfOe rc oaAwIno nD., m FL-16092.9 0 Eq b SHEET 6 or_A_ Florida Building Code Online Page 1 of 4 770Y BQS Home Log In User Registration Hot Topics I Submit Surcharge I stets&Facts Publications Contact Us BCIS Site Map Links •Search•� b a Product Approval a USER:Public User Product Approval Menu>Produc[or Application Search>Application List>Application Detail FL# FL15816-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Wincore Window Company,LLC Address/Phone/Email 250 Staunton Avenue Parkersburg,WV 26104 (304)485-7460 Ext228 mreed@wincorewindows.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Mike Reed ALL WORK SHALL COMPLY WITH PREVAILING Address/Phone/Email 250 Staunton Tumpi Parkersburg,WV 261lyenDES FLORIDA BUILDING CODE, (304)485-7460 ExtNhTIONAL ELECTRIC CODE, mreed@wincorewindM.-THE CITY OF ZEPHYRHILLS Quality Assurance Representative Mike Reed ORDINANCES Address/Phone/Email 250 Staunton Turnpike SEP 0 3 2019 Parkersburg,WV 26104 (304)485-7460 Ext 228 �C`Iiel �pTEvou1 1 S mreed@wincorewindows.com GV 1GOY•C ����l f`n1 1. Category Windows CIN r MINER Subcategory Fixed PLAN EXA Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J.King,P.E. R Validation Checklist-Hardcopy Received Certificate of Independence FL15816 R8 COI (a)Certificate of Independence ndf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1300 2004 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 httt)s://floridabuildiniz.org/Dr/Dr ann dtl.asnx?naram=wGEVXOwtDauea I%2bT71%2fF1•-• 5/19/9019 V r Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/20/2017 Date Validated 08/03/2017 Date Pending FBC Approval 08/07/2017 Date Approved 10/10/2017 SummarV of Products Fl.# Model,Number or Name Description 15816.1 a.8400 Series Vinyl Fixed Window Extruded PVC Fixed Window with"Non-Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.1.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.1 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.1.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.2 b.8800 Series Vinyl Fixed Window Extruded PVC Fixed Window with"Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.2.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.2 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.2.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.3 c.8800 Series Vinyl Fixed Window Extruded PVC Fixed Window with"Impact"Insulated Glass- (Geometric Shape Configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15816 R8 II (b)Inst 15816.3.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.3 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.3.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.4 d.8800 Series Vinyl Fixed Window Extruded PVC Fixed Window with"Impact"Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15816 R8 II (c)Inst 15816.4 odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.4 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.4.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.5 e.8800 Series Vinyl Fixed Window Extruded PVC Fixed Window with"Impact"Insulated Glass- (Geometric Shape Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15816 R8 II (c)Inst 15816.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.5 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.5.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.6 f.7700/9900 Series Vinyl Fixed Extruded PVC Fixed Window with"Non-Impact"Insulated Window Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.6.1)df https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquegl%2bT711/o2tF1... 5/18/2019 ` Florida Building Code Online Page 3 of 4 3 Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.6 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.6.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.7 g.400/500 Series Vinyl Fixed Extruded PVC Fixed Window with Nailing Fin"Non-Impact' Window Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.7 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.7.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.8 h.5400/5400S Series Vinyl Fixed Extruded PVC Fixed Window with"Non-Impact"Insulated Window Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.8.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.8 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.8.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.9 i.5400/5400S/7700/9900 Extruded PVC Fixed(Transom)Window with"Non-Impact" Series Vinyl Fixed(Transom) Insulated Glass Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.9.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.9 for Design Pressure Ratings,any FL15816 R8 AE M Eval 15816.9.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.10 j.5400/5400S/7700/9900 Extruded PVC Fixed(Casement)Window with"Non-Impact" Series Vinyl Fixed(Casement) Insulated Glass Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.10.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.10 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.10.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.11 k.400/500 Series Vinyl Fixed Extruded PVC Fixed(Sidelite)Window with"Non-Impact" (Sidelite)Window Insulated Glass Limits of Use Installation Instructions Approved for use in HVHZ:No FL15816 R8 II (b)Inst 15816.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.11 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.11.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15816.12 I.5400/5400S/7700/9900 Extruded PVC Fixed(Sidelite)Window with"Non-Impact" Series Vinyl Fixed(Sidelite)Window Insulated Glass Limits of Use Installation Instructions Approved for use In HVHZ:No FL15816 R8 II (b)Inst 15816.12.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15816.12 for Design Pressure Ratings,any FL15816 R8 AE (b)Eval 15816.12.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Back FREI httns_//floridabuilding_ora/nr/nr ann dtl-a.nx?naram=wCTF,VXOwtDrnlea 1%2.hT71%IfF1... 5/1 R/9019 Florida Building Code Online Page 4 of 4 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click ere. Product Approval Accepts: Credit Card Safe hth�e•//flnri�ol,iiil�intr nrrr/rrr/"r car%" AA oonv'7r�orom�v(TF�T57(l�:rfllniinnl0/71,T71D/7fli1 G/1 Q11A10 R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Boa 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Dater.- / Product Sub Category Manufacturer Product Name Category Wincore Window Company,LLC. 7700/9906 Series Windows Fixed 260 Staunton Turnpike Vinyl Fixed Window Parkersburg,WV26104 "Non-Impact!' Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E..(System ID#1998) for Wincore Window Company,LLC.based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3.When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2&R301.2.12. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15816.6 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15816.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by ATI B6715.02-501-47 AAMAIWDMA/101n.S.2/A440-08 Architectural Testing,Inc. Lynn George AT[C6371.02-501-47 AAMANVDMA/101/1.S.2/A440-08 Architectural Testing,Inc. Lynn George 2. Miami-Dade NOA Material 15-1201.11 Saflex° PVB Interlayer(Eastman Chemical Co.) 3. Drawing No. Prepared by Signed&Sealed by No.FL-15816.E RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. ASTM E 1300 Glass Load Lyndon F.Schmidt,P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute,certifying that Wincore Window Company,LLC.is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. �G�tGGEEDFLi�G r�F,� 0 .° m NFG P� til;�l 1��',0�9 °E"��ti:EE6G2�'d Lyndon F.Schmidt,P.E. FL PE No.43409 7/1 8120 1 7 Sheet 1 of 1 96"MAX O.A.FRAME WIDTH �'• `�Ty M WINCO�kE �90.63"MAX.D.L.O.WIDTHZ -SH WINDOWS&DOOR =;°S'�••.., yti'�.� a 250 Staunton Turnpike,Parkersburg,WV 26104 ��, ��` o C Coz° 1 tilt r v a.. v Z Z U Em m m 3 9 d o a 7700/9900 Series a m a a n � 4 0 W = u 9z Vinyl Fixed Window 4 ® o K: � "NON-iMPACr' n Z LEI OJ m b o GENERAL NOTES o 2 1. This product has been evaluated and is in compliance with the bth o t Edition(2017)Florida Building Code(FBC)structural requirements excludin the"High Velocity Hurricane Zone' HVHZ. 9 9 Y ( J GLASS;S--;-,DESIGN;PR,ESSURE(PS� y Y> _ :FRAME;:':-.:; 3 2. Product anchors shall be as listed and spaced as shown on details. TYPE: 0 01MENSION.'i' ".,DIMENSION;'';;= ::; P9_SRIVE;i a:NEGATIVE:,; o o Anchor embedment to base material shall be beyond wall dressing "° '' 3 or stucco. 60.0"X 48.0" 54.63"X 42.63" Gt,G4 +50.0 -50.0 n a o c N N Z 3. When used in areas requiring wind bome debris protection this 53.0"X 53.0" 47.63"X 47.63" G1,G4 +50.0 -50.0 m ti product is required to be protected with an impact resistant covering N that complies with FBC Sections 1609.1.2&R301.2.1.2. 72.0"X 50.0" 66.63")(44.63" Gi,G4 +40.0 -40.0 Ln 4. For 2x stud framing construction,anchoring of these units shall be the 84.0"X 40.0" 78.63"X 34.63" Gt,G4 +35.0 -35.0 same as that shown for 2x buck masonry construction. o 0 0 5. Site conditions that deviate from the details of this drawing require 60.0"X 60.0" 54.63"X 54.63" Gt,G4 +35.0 -35.0 further engineering analysis by a licensed engineer or registered 84.0"X 63.0" 78.63"X 57.63" G2,G5 +50.0 -50.0 a architect. � o 76.0"X 72.0" 70.63"X 66.63" G2,G5 +50.0 -50.0 e z TABLE OF CONiENiS SHEET$ DESCRIPTION 84.0"X 66.0" 78.63"X 60.63" G2,G5 +45.0 -45.0 DATE: 4130113 z a 1 Typical elevations,design pressures and general notes SCAM N.T.S. 2 Horizontal cross sections 78.0"X 72.0" 72.63"X 66.63" G2,G5 +45.0 -45.0 DM 13Y.- JK m 3 Buck anchoring CHx.By- LFS 3 4 Frame anchoring DRAWNG NO.: 5 Bill o matenais,components and glazing details 96.0")(72.0" 90.63"X 66.63" G3,G6 +50.0 •50.0 m FL-15816.6 0 sHEET_L OF 5 d R\Cllents\Winmre PERMANSTRA-Florida ProductAppr=ls\FL-1SK6 Fixed Window\C-Drawings\Cwent\FL-IS816.6.dwg,21 m - 2 FoA mm 00 0� C om= A m10, 00 �CL ooN� n � W O m � m m m m CD n 1 03m N W �CL �ao I� � NW N�1JAf� N a m Tv 0 0 0 QXa 0z c) 00 oa zN A N � A I� N 41 m m � .D •� T� a NO EL3 6r _z o� o 0o m w n Z fi) 47 ,SCH�.y/�7G�i 0 en fit 2 I� 40, �• w = No.43409 PRODUCT: D.—nt.Prepared OF 7700 9900 SERIES Lyndon F. Schmidt �10RtOR�••'' � IN Cn a Z W 3 610 1777 UPDATE TO 6TH ED. 2017 FBC LFS P.E. No. 43409 '/��7 e�{.t1;; 1— y 0 2 1 26 15 UPDATE TO 5TH ED. 2014 FBC JK PART OR ASSEMBLY: @�/A'`/BUILDING C.NSULTANi5,1 1A ;;`` Irn � x In 1 5 O2 14 ADDED SIZES GLAZING DETAILS JK VY P.O. Bex 230, Valrieo, FL 33595 O rn w NO DATE BY CROSS SECTIONS Phone No.: 813.559.9197 REVISIONS CROSS CA No. 9813 0 2073 R.W.Bu1LDINa CGNSULTANTB INV. �` •�. � 'y 10"MAX.O.C.(TYP.) 4' �i,'���••... • m •'. ""nit ltTl y U N.. 10"MAX.O.C.(TYP.) 4" n a c Z d �z TYP./D ' E. D �r 2X BUCK a 2X BUCK TYp, MASONRY (� z OPENING m MASONRY "' x OPENING O o o w • U b n " 0 y O ^ 0 o. al G BUCKANCHORING 72"X 48"MAX V BUCKANCHORING a 96"X 72'MAX ^d O N N 2 to W W O CONCRETEANCHORNOTES: N 1.Concrete anchorlocations of the comers maybe adjusted to maintain the min. LO edge distance to morfarjoinfs. a a w 2.Concrete anchorlocatlons noted as"MAX.ON CENTER"must be adjusted to a a o � maintain the min.edge distance to mortarjoints,additional concrete anchors Z a 3 may be required to ensure the MAX.ON CENTER"dimenslon are not exceeded. ^ d Is 3.Concrete onch or fable: WW o ¢ r 9 N O J ._ .:. ANCI�OIi N11N- .. I.:;. . ::: I :.;GHA 0 s '.�::............:::s;:x:Ear"'--:;;::::; TO'M..... R1't��`f;TO%A�IACENt i z ;';s::rrQE >::;:::;;rE:;::b> ::EA� EUMnrr::s.<:;::::>::;:.::..:....;;.,:.vt;;;.:.:;-:>:::s:. ...:..:.:-::::::::. M N o e '" ...TAPCON............./.................................:......:..................EDGE.•::>::;::•:.:::.�::•:::.::d Ok":::": Z o 1iW BarE 4 30 13 E ® 1 4" 1-1/4" 2" 4" ELCO grJrr. N.T.S. w ULTRACON® 1/4" 1.1/4" 1" 4" DWG.Br: JK m WOOD SCREW INSTALLATION NOTES: CHK.W. LFS 3 1.Maintain a minimum 5/8"edge distance,1"end distance,&1"o.c.spacing of mmmNB No.: rc E n wood screws to prevent the splitting of wood. FL-15818.8 0 oSHEET 3 OF 5 %%`�� • . (:•� � �C ���J=fin MASONRY 3 EQUAL SPACES 3 EQUAL SPACES OPENING MASONRY OPENING n i• .' :a• VYP.) �i� .... lilt Z Z m O 96oa md(L l3 LL CZ O FRAME — o€° So'. p 2X BUCK — FRAME4DIREC CK 0¢ 2X BUCK _ a G I BUCK 'v CKDIRECTTO I T TOMASONRY _ NRY — o TYP. _ TYP. x 0 2X BUCK - - girl 0 FRAME ANCHORING a a 72"X 48"MAX LL Q FRAMEANCHORING n a C. 96"X 77 MAX N N 2 ur 9 yg t9i 8 U O CONCRETEANCHORNOTES., o o y I.Concrete anchor locations at the comers maybe adjusted to maintain the min. pq edge distance to mortarjoints. o 0 2 Concrete anchor locations noted as MAX ON CENTER"must be adjusted to � °z maintain the min.edge distance to mortar joints,additional concrete anchors - may be required to ensure the MAX.ON CENTER"dimension are not exceeded n 3.Concrete anchor table: m N iW xairr::rl�nale :::.MiN icERxret: e" AnI ►loa Boom :..:...............:.:... z m <::;Td. p$ R1'iai y QiDJA;CEN►f!: o : i=; :.;::::•: i:ii'tjG'N61 1 N a TAPCON®rTW 1/4" 1-1hr 2" 4" DAM 4130113 c scue N.T.S. d ELCO ULTRACONG 1/4" 1.1/4" 1" 4" DWG.BY. JK m' WOOD SCREW INSTALLATION NOTES: Gt By, LFS 3 1.Maintoln a minimum 5/8"edge distance,1"end distance,&l"o.c.spacing of DBAWNG NO.: rc wood screws to prevent the spiiHing of wood. FL-15816.6 m 0 SHEET 4 DF 5 d m BILL OF MATERIALS IIE18 DESCRIPBON MATERIAL y �1` II -=___� a;'�r O1 L•`�' n A I X BUCK(SG>=0.42) WOOD -i�_ L--�1j B 2X BUCK($G>=0.42) WOOD 0.071" "-�--_22� =N'? z * � O�� o m C 1/4"MAX.SHIM SPACE - ° D INK 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL N AF36(I-]IT Brick Mould) '�� �'••. ���- E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE 0.069" F 1 0.059" ����/ITT 11 P � o n m z 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 a a F #10 X 2"PPH WOOD SCREW(1 7/16"MIN.EMBEDMENT) STEEL r ° O ❑ O OPTIONAL COSMETICo FLANGES " o z G 1 It 2-3/4"HWH ELCO OR IFW CONCRETE SCREW STEEL L° 9•� w H I/4"X 2-1/4'HWH ELCO OR ITW CONCRETE SCREW STEEL T FRAME 'm a a 1 FRAME(PI7701 WH)' PVC f = `d 2 1"GLAZING BEAD(BV79WH)• PVC 0.76" }L ___`__I (r am=�-` 0z •THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY n l(N, EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". �( L JLrL____ 4 J(UJ ■T el—12�5� a AF59(Masonry Flange 1) V672(Masonry Flange 2) w o0 GLAZING BEAD N 1/2"GLASS 2 o a BITE 7/B"THICK GLASS m m 1/2"GLASS 1/2"GLASS I rn �a BITE 7/8"THICK GLASS BITE 7/8 THICK GLASS o 0 0 o 1/8'"ANNEALED o 3/16'"ANNEALED o 3/16"TEMPERED o oZd z o ~rc m na m V �, AIR SPACE AIR SPACE AIR SPACE a 1/8-ANNEALED 3/16"ANNEALED 3/16'TEMPERED V 1- 1/16"X1/2" INTERCEPT SPACER 1/161X1/T INTERCEPT SPACER 1/16'X1/2" INTERCEPTSPACER „q 40 GLAZING TAPE GLAZING TAPE GLAZING TAPE N N z BY LAMATEK BY LAMATEK BY LAMATEK d c z tE GLAZING DETAIL G2 GLAZING DETAIL G3 GLAZING DETAIL w w 2 GT (See GeneralNote3,Sheetl) (SeaGeneroINote3,Sheetl) (See General Note3,Sheet1) xx d 1/TGLASS o � of BITE 7/8"THICK GLASS fe 1/2"GLASS 1/2'GLASS n BITE 7/8"THICK GLASS BITE 7/8"THICK GLASS a a 19 o 0 < 1/8"ANNEALED 1/WANNEALFD 1/8"TEMPERED »¢ _ 9 0.039'SAFLEXOPVBINTERLAYER 0.030"SAFLEKOPVBINTERLAYER 0.030"SAFLFXGPVBINTERLAYER ^^^ P 1/8"ANNEALED 1/8"ANNEALED 1/6'7EMPERED o N o a AIR SPACE AIR SPACE AIR SPACE ° i 1/6"ANNEALED 3/16"ANNEALED 3/16"TEMPERED "�N Z $ oATe 4130113 z a INTERCEPT SPACER Sru.E: N.T.S. ° W INTERCEPTSPACER IMERCEPTSPACER M.BY: JI( m' a II10 X 1/2" 1/16"X 1/2' 1/16"X 1/7' cHK.er: LFS 3 GLAZING TAPE GLAZING TAPE GLAZINGTAPE BY LAMATEK BY LAMATEK BY LAMATEK onAwwc NO.: � e G4 GLAZING DETAIL G5 GLAZING DETAIL G6 GLAZING DETAIL FL—75816.6 a (See General Note 3,Sheet 1) (See General Note 3,Sheet 1) (See General Note 3,Sheet 1) a G SHEET 5 of 5 0 a • Plan Review Windows & Doors 1) Need-.manufacturing installation specifications: 2) .Must meetsections.R308 and R612 of the.2017 F.B.C. 3) If:windows are to be installed inside the historical district,.they will need to be approved by-the-historical committee. .4) No other work shall be permitted (framing; plumbing;'and mechanical) unless otherwise specified.: 5) This.is for replacement(glass for glass) only. If-you wish to change from screen or vinyl windows to glass;then additional information is required. 6: All windows:to wall connections.shall be left visible for.inspection. 7) All.labeling iihd stickers shall remain.06 windows until final inspection.- ' No work shall start without permit first.