HomeMy WebLinkAbout19-21720 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 21720
BUILDING PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 21720 Address: 39352 LINCOLN AVE
Permit Type: RE-ROOF ZEPHYRHILLS, FL.
Class of Work: ROOF REPLACEMENT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: LINCOLN HEIGHTS
Est. Value: Parcel Number: 12-26-21-0280-00000-0270
Improv. Cost: 9,434.00 OWNER INFORMATION
Date Issued: 9/06/2019 Name: SANTOS IDALIA
Total Fees: 135.00 Address: 39352 LINCOLN AVE
Amount Paid: 135.00 ZEPHYRHILLS, FL. 33542-4637
Date Paid: 9/06/2019 Phone: (863)397-2682
Work Desc: REROOF METAL
CONTRACTORS APPLICATION FEES
TRIPLE CROWN ROOFING INC REROOF RESIDENTIAL 135.00
n
I
Ins ec i uired
DRY IN ROOF INSP
TAPE JOINTS ROOF INSP
FINAL
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications Must Accompany Application. All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRA OR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR.INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department 2
Date Received .Z�.��,• Phone Contact for Permitting OQ I J 83 -- ;7;7AO
4J.LLLAA.A.LA.A"1 I I I I I I I L
Owner's Name /�A �']A JA-S Owner Phone Number
Owner's Address L;ncAL Avle A41s Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address'
JOB ADDRESS J g3,5 n co l,, Avc.-� LOT#
SUBDIVISION bAco% Anj 1,.'-S PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR e ADD/ALT 0 SIGN 0 Q DEMOLISH
INSTALL REPAIR
PROPOSED;USE Q SFR 0 COMM Q OTHER
TYPE'.OF CONSTRUCTION Q BLOCK 0 FRAME 0. STEEL Q
DESCRIPTION OF WORK L� lL S lA Al.s !
p D'l�6r X �s
BUILDING SIZE F SQ FOOTAGE . ADD HEIGHT
OBUILDING $ q VALUATION'OF TOTAL CONSTRUCTION
QELECTRICAL $ / AMP SERVICE 0 PROGRESS ENERGY 0 W.R.E.C.
0
PLUMBING $
MECHANICAL Q $ VALUATION OF MECHANICAL INSTALLATION C(
GAS ROOFING SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA AYES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address "License#
':'ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N.
Address License#
PLUMBER.;:..,. COMPANY
SIGNATURE, REGISTERED Y•/-N, FEE CURREN Y/N
Address ; License# :
:'-MECHANICAL COMPANY
SIGNATURE`"' ` REGISTERED Y/ N .J., . FEE CURRE�
Address�' License.# -
.OTHER. >:?:i � �/ � :®COMPANY
SIGNATURE??;:,:', REGISTERED / N FEE CURREN AL Y/N -
aad ess -,License# Ea`14 3 v
_.:;<. -.
`.RESIDENTIAL; ; `Attach(2)PIoC'.P.lans;''(2)set's'of Building Flans;(1)'set of EnergyFonris;R-O.=W.PermIt for new.construction,
`t,Y,. ,Mlnimum.Ktenx(z10)working?days aft6:r mittal date:`Required onsite;�Constn coon Plan§;Stolmwatei�Plans w/Silt Fence Installed,.
Sanitary;Facllities;8%1 dumpster;,Sife;Work.,Permit.forsubdivisions/large'projects': "
:'.COMMERCIAL Attdch(2)�oomplete'sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for`new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities 1 dumpster..Site,Work Permit for:-all-new•pirojects.All commercial requirements must meet compliance
rSIGN'PERMIT i4ttach(2)`sets_of;EngineerediPlans:z--_: s
****PROPERTY SURVEY.requlred,for aII,NEW construction..t;
Directions: ;t:�,�a��.
:Fill.out;application completely.
Owner B.Contractor sign back of application,notarized
-if over$2500;a Notice.of-Commencement Is required. (A/C upgrades over$7500)
Agent(forth'e co ntractor)-or,Power-,of'Attomey(font ie._gvyner)gwould 6e someone with notarized letter from owner authorizing same
OVIEWTHE-COUN
PERMI
SRe oofs if sh ng esTER Sewers NG ervi a Up�orpdeg A/C, Fences(Plot/Survey/Footage)
Driveways-Not over CountdFifon kpub is ioadvy y. •,
I a s:.rieeds'ROV1l
a
NOTICE OF DEED RESTRICTIONS: The undersigned understands..that this-permit may. subj.ectto"deed":resticfions" ;r '+
i �, ..�
which maybe more,restrictive;than County.regulation's:"The undersigned,,assumes.responslbility for'compliahbewirith
appliboble-deed restrictions:
UNLICENSED. CONTRACTORS AND, CONTRACTOR RESPONSIBILITIES_-',If•the�,'tdWner,,has°{hired""i.-contractor.or
contractors to undertake work,,,they may be;required_to be`licensed in accordance with.state:gridlocal,;regtlatiorns:=lf
contractor.-.is:not.licensed-as,,required.bylaw; bothi the owner sand'contractor- may b'e>cited-for a misdemeanor violation,
under state law. If the owner or, intended.,contractor are Uncertain as to what licensing,requirementsarnay.apply for�tf
intended work,they are-advised to coritacfitlie Pa11sco County Buildinglnspectiori Division, Licensing S.ectian at 7274847
8009. Furthermore', if the owner has hired"a contractor'or contractors, he is advised to ;have the,,,contractor(s)s gn ,
portions of the "contractor Block" of this application_.for.which they:will be responsible. Ifyouu, as'the.-owner`slgn;as=the''v
contractor, that may be an indication that he is not3 properly licensed`and'i's not entitled-to permitting privileges.in Pasco.
County.
TRANSPORTATION IMPACT/UTILITIES-IMPACT,AND RESOURCE RECOVERY FEES: "Tile urfdersigned understands.
that Transportation Impact Fees and Recourse Recovery Fees,may-apply to the construction.of-cnew,buildings,."chiiJb6s`of`
use in-existing-buildings,:or,,expansion;:of:exist'i,g buildings, as specked in Pasco County Ordinance number89�o7,and
90-07, as amended., The undersigned also;understands,'that.such'Jees,:as,may;,be.due, will"btie:identified af-th'e':timer:of=':.
permitting. `!t'is further understood that Transportation"lmpact.Feesand Resource=Recovery. Fees must be paid prior`to
receiving,a"certificate of occupancyn or finat,,power release. If the project does not.involve a"certificate of occupancy ol;
final:.power-release,.:the fees'.must be,paid prior to permit issuance. Furthermore, if,Pasco County Water/Sewer,.4mpac
fees are due,.they must_be paid prlar to:permit'lssuance in accordance with applica6le:Pasco.County ordinances.
CONSTRUCTION'LIEN-LAW'(Chapter 713,'Florida Statutes, as amended):. If.valuation.of work is 12,500.00,or.rmor..er
certify,that 1, the,applicant; have. been- provided with-a -copy.:of the "Florida Construction..Lien .Law-= meowner's
Protection Guide"'prepared`by the Florida Department of Agriculture and Consumer:Affairs. If the applicant is.someone., ..
other than the"owner",'.certify that I-have obtained a copy-of the above'described'document and-promise.in goad.`..faith';to
deliver it to the;uowner°prior:to.coinmencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT:.. I:certify that all,the information in this application is'accurate and'that all-work
will be done in compliance with all applicable'iaws regulating construction, zoning-and land--development. Application..is
hereby made to obtain :a.,-permit-.;to do-work and installation as indicated. 1"certify that no work or.installation=has
commenced prlor..to issuance of'a permit and that all work will be performed to.meet,standards of all laws regulating
construction, County and City codes, zoning regulations, and land development`regulations 16,1he jurisdiction. Falso
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include.but are not limited-to-
Department of Environmental:Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,•WaterMastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers--Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater.Treatment,
Septic-Tanks:
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation:Authority-Runways.
I understand that=the following.restrictions apply to the use of fill:
Use of fill-is not allowed in Flood Zone"V" unless expressly permitted.
If the fill-material-is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volumen.will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill" material Is to be used in any area, i certify that use of such fill"will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of-:thebuilding,permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an,engineered drainage plan is required.
if i am the AGENT FOR THE OWNER;.I_p' romise in good faith to inform the-owner of-the permitting conditions set forth in
this affidavit prior-to commencing construction.-:I_understand that a separate permit may be required for electrical work, -
plumbing, signs, wells, pools, air,conditioning, gas,.,or other instailations not specifically included in the application. A,
permit issued shall''be canstriied to tie a license to proceed with the.work and not as:authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans;construction or violations of--any-codes.~Every permit issued shall become invalid
unless the work authorized by such permit is commenced within.six months of permit issuance, or if work authorized by
the permit is suspended-or abandoned-for a period.:of.six(6)months-after the time the work is commenced:.An extension.
may be requested,-in'wriiting, from the Building Official for a.period not`to"exceed ninety-(90) days-and-will demonstrate
justifiable cause for.-the extension. If work ceases for ninety(90)consecutive days,,the job.is considered abandoned.
WARNING"TO OWNER: YOUR FAILURE .TQ RECORD„A NOTICE.OF COMMENCEMENT,MAY'RESULT IN`YOUR
PAYING TWICE'FQR IMPROVEMENTS TO YOUR PROPERTY.. IF YOU'>tNTEND TO°OBTAIN FINANCING:CONSULT
WITH YOUR`CENDER OR AN AATTBRNEY BEFORE-RECORDiNG YOUR NOTICE-OF'COMMENCEMENT.'
—._.___-PI:QRIDA-JURAT-(F.S.11�?A3)- - --- - =- —--... � :Gi.c.��./ - - -
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)before me this Subscribed and wom to(or affi ed)b fore a this
by ^
Who is/are personalty known to me or hasihave produced Who is/are a onally R own to me or hasihave produced
asidentification. as identification.
x
Notary Public ' Notary Public
Commission No. Corn issi No. ":'^•.
' �a+►r+r+atilontt�G2 S
Name of Notary typed,printed or stamped Name of Notary type ," , 12,anoed lfw-TmpF�tgtif�uraag00.38sT0i9
r.tiy
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: (V wn
r -
Date Received: 0- Z,7-19
Site: ,3gJ67 2 L✓d l C��/1
Permit Type: /7 'e'Af r '
Approved w/no comment Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
SEP 0 5 2019
Kalvin S —Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
INSTR#2d19145165 OR BK9962 PG 3451 Page 1 0€1
08/27/2019 01:13 PM Rcpt:2084961 Rec:10.00 IDS:0.00 IT:0.00
Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller
Parcd lD No Ia-;k t 2-/-080- 06WO-a a7o
NOTICE OF COMMENCEMENT
Stataoi /��} CawttyofAsco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain reel property,and In acrordadce with Chaptar 713.Florida Statutes,
the f eDwIng tnionneton is provided In this Notice of Commencement:
1. Description atPmpw.Parcel Identification No, 1-1+7COIn&441f3sMe P8I.3p65113 l/z/fora-'oR faltllr 5d- 7
steratncdms5: 3g3S� Laneel., Ave- 2�1 �.tlIf A 83.5-
Y. General Description artmpmxernant 1QC"P�6+CJAJ4
S. Ownerintormation or Lesseehdotrnat3on lithe Lessee contracted for the improvement
/A4L
Address �Gt City State
..
interest in Pmpe Q t- W
U
Ix W
Noma of Fee S6mpteStttslmtder tzL) LL W W
LL-
d fferent from Owner tasted above) 0
z = O O
4 Addmss /N city State U (n N O
a- (D :r < (k
te
n
Gr �7 e. �i./�i-j /2 335�/.� LL. � a z ( c�i a
tltdress ?/•' s // �CRY I stela ® O D o
ContmctofaTolepttatelYa W LL il� 4.)C,()
5 @way Name- - - O UO Li-LL- Jag
0t� aut0
Address City State .� O ry, O
AmowrtofBond:S Telephone No--
Z U U
0. Landers F- d
�17 Ump LL
A ai X S911 �L'�� `5'2/ sit LlJ C�� I tom-- W a Q O
.: city State 0 CY_ X LL. M
Lenders Telephorm No.! --t LLI O O
LL-
7. -Peson3 within the State of RmIda designated by the owner upon whom notices or other doc ments may be served as provided by LL 0.0 Q
Section 713.13(1)(a)M,Florida Statutes ,J 0 F- Z W
/r W
Name
Address,. city - sta<e In F- l O CCl
Tatephone Nttmber of Designated Pom=
01 In addition to tdmaetf,the owner designates _ of
to receive a cetryof the Lienor'sNotce as pmNded b1$ertkn 713.13{1)(D},Ftodda Standas. e s
Telephone NumbwofPerson ar`Et MyDedgnatsd by Omer
e
0. F-VIration data of Notice of Cam encenent(the a0raton m date may not be before the completion of cabuction and final payment to the
Ontr xlo,bid vM be one year" date of rarnnfmg tmtess a Mitten data is spar&*. 9 o
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT �� � � � o
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1. SECTION 713.13, FLORIDA STATUTES.AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE J08 SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO 08TAtN FINANCING.CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of hay,I declare that I have mad the foregoing notice of commencement and N tated at the(acts s therein am true to the best
of my latowtadge and belief.
STATE OF FLORIDA
COUNTY OFPASCO
tz;_—
SignatumWOwnarorLeCi6k cw Owners ortessee'sAuthoraed `ri
OfricBn(UDilec},iatlP agar
sign aT9 roffice -�
The foregoing Instm M was adarreA ed p ma titU;�Jdayaf V 204 by_=1/,,.
as � (type of authority,e.g.,Officer,trustee.attorney in fad)for
-�// (name{{ rtyen�whom'simmentlwasexecu
Perraney Ifrhrnvn I3�8 d ttlH rt Notary Slgnatum I c lrt�A �*
Type of IdentMeaton Pronc�aed Name(Print) . Ir L d 1 U L
WVVVW
et N "I3�trf fo NStI� of .
W Commission GG,345W3
wp�lettxshwptammmencmnerdpcuS3t48 or� �IeaCB/18/20?3
36
rForcengineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Product Evaluation Report
TRI COUNTY METALS
29 Ga. Ultra-Rib Roof Panel over 1x4 Wood Purlins over 15132"Plywood
Florida Product Approval #4595.22 R4
Florida Building Code 2017
Per Rule 61G20-3
Method:1—D
Category:Roofing
Subcategory:Metal Roofing
Compliance Method:61G20-3.005(l)(d)
NON HVHZ ALL WORK SHALL COMPLY WITH PREVAILING
CODES FLORIDA BUILDING CODE,
Product Manufacturer: NATIONAL ELECTRIC CODE,
Tri County Metals AND THE CITY OF ZEPHYRHILLS
301 SE 16t'Street ORDINANCES
Trenton,Florida 32693
Engineer Evaluator: w 0 5 2019
Terrence E.Wolfe,P.E.#44923 REVIEW DATE
Florida Evaluation ANE ID:1920 CITY OF ZEPHYRH
Validator: PLAN EXAMINER
Brian Jaks P.E.#70159
Contents:
Evaluation Report Pages 1-4
c E N
STATE OF ;
0 J 0
�'0 �F;
Sub ors .0i V-,- . N
CAA �I S
M� 1�''�Or1 111{►�,,,
FL#4595.22 R4
Aujzust 14, 2017
rForcengineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017,Sections 1504.3.2,1504.7.
Product Description: Ultra-Rib Roof Panel, Min.29 Ga.Steel, 36" Wide,through fastened roof panel
with fasteners through the panel rib over 1x4 wood purlins over one layer of
asphalt shingles (optional) over min. 15/32" APA Plywood decking. Non-
Structural Application.
Panel Material/Standards: Material: Min.29 Ga.Steel conforming to Florida Building Code 2017 Section
1507.4.3.
Yield Strength: Min.80.0 ksi
Corrosion Resistance:Panel Material shall comply with Florida Building Code
2017,Section 1507.4.3.
Panel Dimension(s): Thickness: 0.016"min.
Width: 36"maximum coverage
Rib Height: %"major rib at 9"O.C.
Panel Fastener: #9-15 x 2" HWH Woodgrip with sealing washing or approved equal through the
panel rib
%"minimum penetration through plywood
Corrosion Resistance:Per Florida Building Code 2017,Section 1507.4.4.
Substrate Description: Min.1x4 No.2 SYP wood purlins over maximum one layer of asphalt shingles/felt
paper(optional)over min.15/32"thick APA rated plywood over supports at
maximum 24"O.C. The 1x4 wood purlins shall be fastened to the plywood with
(1)8d x 2%'Ring Shank Nail at 4"O.C. Design of 1x4 wood purlins,plywood and
plywood supports are outside the scope of this evaluation. Substrate must be
designed in accordance w/Florida Building Code 2017.
Allowable Design Uplift Pressures:
Table"A"
Maximum Total Uplift Design Pressure: 52.5 psf 131.0 psf
Fastener Pattern Through Panel Rib: 911-9"-9"-9" 9"-9"-9"-9"
Fastener Spacing: 24"O.C. 6"O.C.
*Design Pressure includes a Safety Factor=2.0.
40
IVo.444� /
w �
•s' STATE OF ;a
pro
FL#4595.22 R4 Aupzust 14, 2017
Force Engineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2014,Section 1504.3.2,1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017,as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ UL 580-06-Test for Uplift Resistance of Roof Assemblies
■ UL 1897-2012-Uplift Test for Roof Covering Systems
■ FM 4471-92-Foot Traffic Resistance Test
Reference Data: 1. UL 580-06/1897-04 Uplift Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.136-0084T-14A,B.
2. FM 4471-10,Section 4.4 Foot Traffic Resistance Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.136-0027T-12C.
3. Certificate of Independence
By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc.
(FBC Organization#ANE ID:1920)
Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard.
The FM 4471-10,Foot Traffic Resistance test standard is equivalent to the
FM 4471-92,Foot Traffic Resistance test standard
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017,including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12,lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
No.449�W /
• iJ_
-a- STATE OF :ar►
ODA. At
FL#4595.22 R4 August 14, 2017
Force Engineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Underlayment: Per Florida Building Code 2017,Section 1507.1.1 and manufacturer's installation
guidelines.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure,appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for roof cladding
wind loads.These component wind loads for roof cladding are compared to the
allowable pressure listed above.The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover.Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading.
ACE
CRNSF�,n�ri
No.444� �=
STATUE OF ;
Zop
Sttlr Aofllytiy Imo,;ss
pxna I��
FL#4595.22 R4 Auaust 14, 2017
i
MINIMUM 29 GA. ULTRA—RIB PANEL
36"PANEL COVERAGE
9" 9. 9.. .- 9.
CONK AWS TAPE SEAT.
FOR USE ON SLOPES
LESS TRIN 3:12
N9-15 2' WOODGRIP HWH W/ WASHER
�fx4 WOOD PURLINS ATTACHED TO PLYWOOD WITH
� x
9'-9'-9'-9' FASTENER PATTERN (1).8d x 2 112' RING SHANK NAIL AT 4' O.C.
ONE LAYER OF SHINGLES OVER ONE LAYER OF 300 FELT (OPTIONAL)
OVER MINIMUM 15/32':PLYWOOD
Qsy�y 0 as 3 aP,a�pAG`^
< r
q��V,eee rues VYQ pdd� _
sra a4��2 .°° CE N
JF
dt`cu'r'7d m f>u
hl o.
4492
„�QA.� '� v •yy
FPtt n r
s 00 ,��a
iC�V�l1 �%l 4
PofAC 8go angno,�i��000
AUG 1 4 2017 1 -