19-21892
CITY OF ZEPHYRHILLS 5335-8TH STREET ` (813)780-0020 21892 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 21892 Address: 6613 WAGON TRAIL ST Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: ook: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVERADO Est. Value: Parcel Number: 05-26-21-0080-00600-0330 Improv. Cost: 36,900.00 OWNER INFORMATION Date Issued: 11/07/2019 Name: GARDNER, MARIA& DAVID LLOYD JR Total Fees: 337.50 Address: 30011 PLAYA DEL REY LN Amount Paid: 337.50 WESLEY CHAPEL, FL 33543-6799 Date Paid: 11/07/2019 Phone: 813-892-5978 Work Desc: INSTALLATION ROOF MOUNT SOLAR PV CONTRACTOR(S)- APPLICATION FEES SOLAR BEAR LLC BUILDING FEE 337.50 2zo Ins ections Required FOOTER 2ND ROUGH PLUMB MISC INSULATI N CEILIN FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTtACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020_ City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 727 940.3256 -rrrrrrrr Owner's Name ARDNER NADIA MARIA&DAVID LLOYD JR Owner Phone Number g Owner's Address 1 30011 PLAYA DEL REY LN WESLEY CHAPEL,FL33 3 Owner Phone Number Fee Simple Titleholder Name I I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6613 WAGON TRAIL STREET,ZEPHYRHILLS,FL 33541 LOT# F33 SUBDIVISION SILVERADO RANCH PARCEL ID# 05-26-21-0080-00600-0330 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT � SIGN 0 Q DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR 0 COMM = OTHER TYPE�OFCONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 123KW BUILDING SIZE SO FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 36,900 AMP SERVICE = PROGRESS ENERGY 0 W.R.E.C. =PLUMBING $ 2(5.q?i =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ll VV =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# ELECTRICIAN JOMPANY SOLAR BEAR LLC SIGNATURE REGISTERED N I FEE CURREN I Y/N Address 6101 JOHNS RD STE B TAMPA FL 33634 1 License# I EC13009020 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIItIltltt111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonmwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A' in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR— Subscribed and sworn to(or affirmed)before me this Subscribed and`swom-to,(or-aff d)before.me this �7 by _eby— Who is/are personally known to me or hasihave produced Who,is/are personallpknown4o me or-has/have produced DL as identification. ° ~D as identification. L Notary Public w ublic Commission No. Commis on Name of Notary typed,printed or stamped Name of tart', rint UM Commission#a0 27M7A-%` 67 Expifes December 12,2022 °:i`O Somw T n liq Palo Imutlow 000.355.7019 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: C Date Received: l L Site: 3 w 0)-7 1 Permit Type: ln S 1 6 0 h �d /d-►� Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment et shall be kept with the permit and/or plans. OCT 0 5 2019 Kalvi witzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) DocuSign Envelope;ID:ElE872F4-DF85-4DB4-9CCC-6511C546870C SOLCOMMERCIAL EAR R F E1C-CiES SOLAR BEAR LLC 6101 Johns Road,Suite 8,Tampa,FL 33634 Your Solar Solutions Provider (727)471-7442 W W W.OURSOLARBEAR.COM EC13009020 SOLAR HOME IMPROVEMENT AGREEMENT DATE: CUSTOMER NAME(hereinafter,the"Customer") 9/5/2019 David Gardner ADDRESS:6613 Wagon Trail St CITY,STATE,ZIP: Zephyrhi l l s, FL 33541 HOME PHONE NUMBER: WORK PHONE NUMBER: MOBILE PHONE NUMBER: 813-892-5978 EMAIL: bud5096@yahoo.com This Solar Home Improvement Agreement(this"Agreement")is between Solar Bear LLC("Solar Bear","we"or"Contractor")and you("Customer")for the sale and installation of the solar system described below(the"Project"or the"System")at your home (the"Property"or your"Home").The Parties agree as follows: 1. Was a full years usage of the customers electric bills provided? YES x❑ NO a 2. If no,does the customer understand we can not guarantee a 95%-105%of the previous YES NO a years usage. 3. Does the customer understand the ITC 30%TAX CREDIT is based on their taxable income?YES NO ❑ IF YOU DO NOT PAY INCOME TAXES YOU DO NOT GET ATAX CREDIT El PROPOSED SYSTEM SIZE PURCHASED SYSTEM SIZE (Based on 12 months previous usage) 12.3 KW 16801 KWH ANNUALLY 12.3 KW 16801 KWH ANNUALLY CONTRACT PRICE AND TERMS OF PAYMENTS. I understand,that if I cancel, I will be held financially 36,900 responsible for the cost of the permit and any work that Total System Cost: may have taken place. D—sl'-d W. Check Here If Any Portion of the project Sign E a"il GaY'b kr Total System Cost is Financed. 9/5/20 If checked,the Customer will receive a separate Date agreement from the Finance Provider outlying their terms and conditions. AMOUNT PAID TODAY:$ BALANCE REMAINING:$ 36,900 >7G *An explanation of the Recommended System Size has been explained to me and I have a copy •An explanation of the Federal Investment Tax Credit(ITC)has been explained to me and I have a copy INITIAL NOTICE OF RIGHT TO CANCEL THIS IS A LEGAL BINDING AGREEMENT AND YOU MAY ONLY CANCEL THIS AGREEMENT PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS AGREEMENT.TO CANCEL THIS AGREEMENT,PLEASE SEETHE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT.THANK YOU FORYOUR ALLOWING USTO SERVE YOUI 9/5/2019 Customer Signature: 17avi4 C-ard"'r Date: Customer Signature: Date: 9/5/2019 Representative: JWw bdr6wc Date: DIRECTORY OF PAGES SCOPE OF WORK P-124191 PV-1 PROJECT SUMMARY O - THIS PROJECT INVOLVES THE INSTALLATION OF PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE PV-2 SINGLE-LINE DIAGRAM ;'ia RACKED USING A PREENGINEERED RACKING SYSTEM.THE PV3 SAFETY LABELS ''- RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH '= DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE L MODULE DATASHEET { LOCAL UTILITY USING MEANS AND METHODS CONSISTENT BAY AREA X OPTIMIZER DATASHEET >' WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND �pd&rN z + PERMITTING JURISDICTION. LU INVERTER DATASHEET a INEERING LETTER DESCRIBING THE DESIGN OF PROPOSED PV SYSTEM WITH MOUNTING SYSTEM ENG THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF W W UL 2703 GROUND AND BONDING CERTIFICATION ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH I-"-' 0 + APPLICABLE CODES AND REGULATIONS.THE DOCUMENT U) SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR W � PROJECT DETAILS FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. U) Q to w THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS PROPERTY OWNER DAVID GARDNER '�( LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL Uj (n J CM r- APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE LLJ 6'613 WAGON TRAIL ST, INTERPRETED IN A WAY THAT OVERRIDES THEM. PROPERTY ADDRESS o=. Ll ZEPHYRHILLS,FL33541US -, CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL O F— APN ;y CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. d. Ofz (n ZONING RESIDENTIAL 3 W Z —j USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING hmp dataDzols SYSTEM DETAILS p 0 = CLASSIFICATION GROUP(GROUP R3) NEWGRID-INTERACTIVE 0 Q 1 PLOT VRATING ON PHOTOVOLTAIC SYSTEM WITH NO � Q �- AHJ PV-1 SCALE:NTS BATTERY STORAGE (� Ch = UTILITY COMPANY PROGRESSENERGYFLORIDA INC _ _ _ OF SYSTEM 12,300W Uj U CO LLI L-' ELECTRICAL CODE 2014 NEC(NFPA70) '� .0 OF SYSTEM 10,000WC0 N FIRE CODE 2015 NFPA 1 61° TCURRENT 42.OAS) 1 X SOLAR EDGE SE1000OH-US CONTRACTOR INFORMATION Richland, MODULE SILFAB SLA300M COMPANY BAY AREA PROJECT SOLUTIONS - ARRAY WIRING (1)STRING OF 13 LICENSE NUMBER mr (2)STRNGS OF 14 ADDRESS 2512 BAY FIELD CT,HOLIDAY_FLZ " .', s's 1 ,•' ,�.i I ;' /;, � 34691 ® INTERCONNECTION DETAILS PHONE NUMBER 27 543-8361 C � Zephyrhflls < ''Q North NEW SUPPLY SIDE AC CONNECTION CONTRACTOR POINT OF CONNECTION PER NEC 705.12(A) -_ SIGNATURE 4 ��•� Wesley _ - UTILITY SERVICE 120/240V iQ -q� Chapel South _ f-'1 \�f'� r��•� r P—,�* a. Zephyrhills Zephyrhills. f)pper,. - '('1 n QS West-. Hdtsbor(X gb&., 0 Pres¢rve' tt�" t� �) �• I n 1P6 Hr 7D =coo . Skydive citviz+ldl d SITE DETAILS >� � ZeSlouth IHs ASHRAE EXTREME LOW 1°C(34°F) /��•"-�/1(�1)`),� , "n f�9 " .t ASHRAE 2%HIGH 34-C(93°F) ','R^n pJnF/LCpZ•T� ��' • -I.tap dam®Zola Gaa3le CLIMATE DATA SOURCE ST.PETERSBURG CLEAR "�I'VI',rt„I,Y�111 -0 WIND SPEED 160 MPH(ASCE7-10) DOC ID:124191-154891-1 �O O^y 2 LOCALE RISKCATEGORY II DATE:9/3019 SCALE;NTS WIND EXPOSURE CREATOR: CATEGORY REVIEWER: GROUND SNOW LOAD I REVISIONS r r PV-1 PV MODULE P-124191 MODULES GENERAL ELECTRICAL NOTES + �OPRMIZER REF, OTY. MAKEANDMODE PMAX PTC IBC IMP VOC LAMP TEMP COEFF OFVW FUSEMTING I PM141 4+ SILFPBSLA300M 30D1F 9GN 811A 9+aA 68BV 32BV a1Nrc(aa3M•q UTILINHAS24-HRUNRESTRICTEDACCESSTOALL 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE T PM7-01 INVERTERS MA SERVICE ENTRANCE. 30ow P. MAI(EANDMODB. PDVOLTACE IXtaNO M41(OCPORgnxc ELDPoWER MA%WT41rWRRBIT MP%INPurcuRRFNT MAXINPUT40LTA(;E CECWBGHIEOEFFlCIENCV MODULES CONFORM TO AND ARE LISTED UNDERUL1703. 1141N 114M 1131N I 1Q Q2 I1 + 95ER.OESEt0000H415 240V UNCROUND® 60A +O,OODW 420A 9B4 dBOV 990% 2 1sTRxc 1STRING'1sTRlxc CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS Q Qq POWER OPTIMIZERS REF. QTY. MODEL RaTm INPUT POWEa MAXWTPUTWRRENi MAx1N41T Isc MnxDcvoLTac;E WEGHIEO EFPICENCY 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300,E(C)(1)AND BAY AREA �© P01-01 41 SOLAR EDGE; 320W 15A 110AI 40V 988% PMfd i*+u ARTICLE 310.8(D). I I I REF DTY. PASS-THRU BOXES AND COMBINERS MAxEAND MODEL RATED cuaawt r.+Axy,TEDvaTe„E CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE I L_ BI I GENERCGENAW6TB/i-0%ORCR]UM. ]04 24wacFSWvac 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE I 1 DISCONNECTS OCPDS 310.8(C). Lu J UNCTION BO X �RER' OTY. BOA 240VP MAKEPNO MODEL PATEO WRREM MAXRATEDVOLTAGE REF Ow. RATED CURRENT MAXVOLTA(E W L_^ 1 EATCN OG22U4R8 OREWIV. B14 24DVAC FI-2 2 C (-- w �, GROUNDING NOTES FUN—B YSTEM SUMMARY NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE >- U 1 ZSTRNGI STRING2 SRUNG3 I OPNMMHiS PROM OERARDSHUMDMMNCTIONALIT]REWIREDBYNEC690.12 1 (n Z F— d' INVERTERumrrWRRENr 15A +SA +5A REQUIREMENTS OF NEC ARTICLES 2508690 W w Lo I ERES 14 l4 13 THE SPEOREOOPTIMZEi CAN BESUBSRMED'MTHAP400,P405,P370,P505,ORPl40.THEN OFIMIZERS HAVE ANIN41TVOLTAGEWINWWWIOE PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS W C_ . co 1 111D,000W4DLTAGE 40P/ 40aV dOOV �ENO�TOACWMMODATETHEWTRRY9LTAGEWWG>EOFTHEMODULEATTHEDESIGNTEMPEATURES,HAVEAMAXINPUTCURRE4TRATINGTHAT USING MODULE LUGS OR RACKING INTEGRATED W co-NGCURRE4T fOS4 105A 984 IS ABOVE THE M4COUTPUTCURRENTOF THE MODULEANDAMAXPOVIERINPUT THAT 0 PBOJETHE RATED PONEROUTPUTCF THEMODULE ER 2,3 M1Y 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. wI ER ++•� ®UN OUNDEDSYSMMMC DUCTORSSH ECOLOR OMFWLOWS.DCP0.5UIVESHALLBERED(ORMARKEDREO)PMWNEGATIVESRkL ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED Of �L = T 4M BE BLACK(OR MARKED BLACK) C/3 r� IITPUR I0,000N USING UL-LISTED LAY-IN LUGS, W Z —1 ERATEDACPONERWTRIf f0,000N ALL META-INCLOSURES,RACEWAYS,CABLES AND EXPOSED NONWRREMCAARYING METAL PARTS OFEOUIRAENTSHALLBEGRWNDEDToEPRTHAB INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS z J_ I A,REQUIRED BYNED25041BIAND PART IsOFNECARTIC1E250ANOEQUIPMEMCROUNDINOCONDUCTORRSHALLBESIZEDACOORDINGTONECM45. BEEN EVALUATED FOR COMPLIANCE WITH UL27O3 QCD I THEGRWNOINGREMMESYSTEMSHALLAOHERETOM4](B)MD250IBO THE DC GROUNDING ELECTRODE SHALL BESIZED ACCORDINGTO250168 3 J Q Q I 'GROUNDING AND BONDING'WHEN USED WITH PROPOSED O � UT__.-. 4 MI ADDmoNALMMV GROUNDING ELECTRODE SHALL BE INSTALLED IN ACCORDANCE 4WTH NEC SECTIONS 25052 AND 25o54 UNLEBSTHEARMv PV MODULE. � Q ®STRUCTURE ISSUITABLETOSERVEMAGRCUNDINGELMTRODEMS NECSECRON2502THELQMSERVF WB EA9PAYISIMEG NTHTHE ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED p Ch = - PVSYSTEM ARRAY,OR THE PREMISES EXISRNGWIRNG ELECTRODE IS LOCATED WITHIN 6FT,ASPER NEC SECTION 69047(D) 4 �� r— L__.., 60A DISCONNECT FOR THEIR PURPOSE Ly m co W r_� SIMI ®MAX DC VOLTALEOF ARRAY FIXED BY THEINVERTERAT40W REGARD LFSSOFTEMPE WRETHEMAMO TAGEOFTHEMMULEATI-CIS IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A I— cc) N I 60A EXPBC TOBE42N(1'C-M-C)Xa12J -M8W-42NA 6 wSYBTELOCATENNECHIN IO F BEAVIS TY ME KNIFE-BLADE TYPEOIBCONNEGT THATIBACCEBSI&SAND LOCKABLE BYTHEUPUTV.THE DISCONNECT 6 VERIFIABLE GROUNDING ELECTRODE,IT IS THE p Q 8 CONTRACTOR'S RESPONSIBILITY TO INSTALL A 1 (200AMSPWI200AMCB) SHALL BE LOCNTm WIR9N to FTCF UTUTY METFIR I SUPPLEMENTAL GROUNDING ELECTRODE. ®LEI WSCORNE WIS ON,INH UPRYSMD NEFRMCEDISCONNECT,ATALCCNLYAPPROJmCONNECRONPOM,USING LOCALLY-AaPROYED AC SYSTEM GROUNDING ELECTRODE CONDUCTOR GEC I METIWSPND HA90WARE,INCIX441PNCE WITH NEC]0512(A) (GEC) TA ns 6 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS IF BARE WIRE. CURREdHN"Nc EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED CCABLE/ TE4P.TOR FILL CONT MAX CURRENT BASE OERATED TERM AMP.INTEING TYRCAL CONDUCTOR CONDUCTORS INCDNOUITI OCPO E(A; CAE CABLE FACTOR FACTOR CURRENT (125%) AMP AMP iEMP.RATMG hIAP.RATING ! ', ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF R UTILITY METER , 2 10AWGwRIRE, FREEPIR NIA WA BPIYG B4RE CO'PER 0.7i(56'C) 10 164 18754 NA 39a5A 75'C 50A 7 1 , Ac KWHR 24GnzGv1m,3w 10A THlYNz IDANGTHWNz #10AWGWHENNOTEXPOSEDTODAMAGE,AND#6AWG GEC 2 1 COPPER o.TYDIALFNG 6 WA COPPER071(56•C) as 16A 1875A 40A M72A 90-C 40A SHALL BE USED WHEN EXPOSED TO DAMAGE 10 AhU WIN RE GROUNDING AND BONDING CONDUCTORS,IF INSULATED,'. , 1) 3 1 COPPER FREENR WA WA 6AWG BARE COPPER 071156'Cl 10 ISA 1875A 55A 39064 ]5'C 50A 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF _ 4 1 6AWGTNWN-Z 075-DIALFNC 2 WA IOAWGT Z, 096(34-C) 10 4M USA TEA 72A 76-C BSA COPPER COPPER #4AWG OR LARGER I.• ,(� I 1,�\ 6AW3THWN-2 10AWGTHWN2 J ' 5 1 COPPER 0.75-DIA LFNC 2 WAX2 COPPER om(34'C) 10 4M 625A TEA 72A 75-C `SIN*E,-LI N�I DIAU RAM PROJECT ID:124191 DATE: 09/30119 CREATED BY: SOT CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV-2 SCALE: NTS •/�� M900WMENi HASBFBNCRFATEDFORMERIR MOFMSMINNOTEDE MCFARi0FO6 WOTONOLTNCFVNERSY9TEMWTHENOUMDRNLTODEMONSTMTECWAIM'M MHALLMNCi =ESANOREGNATIONS WEOOWMENTSHOU HMSEP MUMNASAWBB wnfOR �`/_ L Fd40K1NOWNUFACNRFRINVt TIONMWUALS.NSTABERWMLNSTAllN MWl1WWACCORGW(IL WNUFAC RINSTAW MMWUAWNOMNOINTNISWMMEMSHMWBEINIFAPRETEDINAWAYMATOWRRIOESTHEINSRiMONSMMWUM-MRIN5TP1lATM WUNUI V DC RACEWAYS POINT-0F•INTERCONNECTION OR AT MAIN EACH DEVICE WHERE ENERGIZED, LABELING NOTES P-124191 . O SEE NOTE NO.4(DC RACEWAYS) O O UNGROUNDED CIRCUITS MAY BE EXPOSED O SERVICE DISCONNECT(MSP) DURING SERVICE.(JB1,11) •I ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC I AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. uI 4 1 CAUTION 1 ". c l WARNING I _ LABELS,WARNING(S)AND MARKING SHALL COMPLY JBI-TRANSITION BOX `I POWER TO THIS BUILDING IS ALSO FROM ROOF ELECTRIC SHOCK HAZARD.THE DC WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, (MODEL NOT SPECIFIED ! e e I� WARNING,AND CAUTION SIGNS USED THE STANDARD BAYAREA • • • ® ® MOUNTED SOLAR ARRAY WITH SAFETY CONDUCTORS OF,THIS PHOTOVOLTAIC SYSTEM- HEADER COLORS,HEADER TEXT,AND SAFETY ALERT *a O O DISCONNECTS AS SHOWN ARE UNGROUNDED AND MAY BE ENERGIZED. SYMBOL ON EACH LABEL.THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50%TALLER NEC69091(G)(3)AND IFC605.11.1 NEC 69056(B) NEC 690.35(F) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). 11-INVERTER EACH DISCONNECTING MEANS FOR W LLI O4 O DC DISCONNECT 01) O6 AC SOLAR DISCONNECT(SW1) A PERMANENT PLAQUE OR DIRECTORY SHALL BE I--• V SOLAR EDGE SE70000H-US PHOTOVOLTAIC EOUIPMENT(J81,11) INSTALLED PROVIDING THE LOCATION OF THE SERVICE _ 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC } z O O O SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME N W CnI WARNING I NT:27.OA LOCATION IN ACCORDANCE WITH NEC 690.56(B). _ELECTRIC SHOCK HAZARD.DO NOT TOUCHNESM GE:400V .J MSWi-DISCONNECT TERMINALS.TERMINALS ON BOTH LINE ANDAGE:480V PHOTOVOLTAIC AC DISCONNECT LABEL(S)WITH MARKING,'WARNING PHOTOVOLTAIC WEATON DG222URB LOAD SIDES MAY BE ENERGIZED IN THE OPEN POWER SOURCE;SHALL BE LOCATED AT EVERY 10 W —1 POSITION. - ENT:45.OA FEET OF EACH DC RACEWAY AND WITHIN ONE FOOTOF � n EL OO O O EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE 6 7 8 9 NEC 690.17(E) NEC 690.53 NEC 690.13(B) AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS AND BARRIERS.THE LABEL SHALL Lll O J ANY AC ELECTRICAL PANEL THAT IS FED BY HAVE 3/8'TALL LETTERS AND BE REFLECTIVE WITH Z MSP-MAIN SERVICE PANEL O SEE NOTE N0.5(SWi) OB AC DISCONNECT(SW7) O BOTH THE UTILITY AND THE PHOTOVOLTAIC WHITE TEXT ON A RED BACKGROUND 0 Q = SYSTEM(SWI,MSP) _ LABEL(S)WITH MARKING,'PHOTOVOLTAIC SYSTEM O O fy EQUIPPED WITH RAPID SHUTDOWN;SHALL BE LOCATED Q 9 . I 1 AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE c/) M(D 2 • • • B MAXIMUM ACOPERTINGCURRENT:420A IWARNINGI 5 DISCONNECT THE LIBEL SHALL HAVE 3/8'TALL 0 6 ®® MAXIMUM ARAl1NGVOLTAGE:240V DUAL POWER SOURCE.SECOND SOURCE IS LETTERS AND BE REFLECTIVE WITH WHITE TEXT DNA W cc W PHOTOVOLTAIC SYSTEM. RED BACKGROUND CD N NEC690.56(C)AND IFC605.11.1 NEC690.54 NEC 705.12(D)(3) 0 l )I0A i tf SArETY,Ll A8ELS DOC ID:124191-154891-1 DATE:913019 CREATOR: REVIEWER: REVISIONS PV-3 Test Conditions STC NOCT ...... .. �� Module Power(Pmax) Wp 300 227 -.L •ii 3 M Maximum power voltage(Vemax) v 32.8 29.5 Maximum A. +.` power current(Ipmax) 9.16 7.69 4^ 8'' y, SLA / 1 P Open circuit voltage(Voq V 39.85 36.9 ShortGrcuitcurren[(Isq — A _ 9.71 _ 7.96 p ...r° Module efficiency % - 18.4 17.3 $®6dR % Maximum system voltage(VDC) V 1000 _ •^�:?`.;��% Series fuse rating A 20 _ Power Tolerance Wp -045 ® ® ® O ® ® Meaiwem rrc rnnErtlors 51C 1000 W/m3.AM1.5.TemPera[ure15•C.NORBOO W/ms.AM 1.5•Measurement unrerhlntY53% •• _— aun simulator calibration reference modules hom Fraunbofer Intltu[e.Elecmral daraaerlstlrs mayvaryby25%andpower byU/�a. Temperature Coefficient Ise %/K 0.03 Temperature CoeffiGent Voc %/K -0.30 Temperature Coefficient Pmax %/K -038 INDUSTRY LEADING WARRANTY o Gratin tem erature C 40/+8s ® - ® All our products include an industry '•• - 'x`�1, .' •''"�, ' leading25-year product workmanship Moduleweight(11kg) kg __ 19. Dinn refons(H x L x D;31mm) mm 1650x 990 x38 - and 30-year performance warranty. Maximum surface load(wind/snow)* N/me 2400 Pa upward/5400 Pa downward �^ ® d Hall Impact resistance o 25 mm at 83 km/h 35+YEARS OF SOLAR INNOVATION Cells GO-5imonocrystalllne•4or5busbar-156.75x15 775Mrn ® ® Leveraging over 35+years of worldwide Glass 3.2 mm high transmittance,tempered,antlrefiective coating experience In the solar Industry,Silfab Backsheet Multllayer polyester-based Is dedicated to superior manufacturing Frame Anodized Al(Black) _� processes and innovations such as Bypass diodes 3 dlodes-45V/12A IP67/I1`68 _ Bifaclal and Back Contact technologies, Cables and connectors(See Installation manual) 1200mmo5.7mm(4mm2),MC4co(1i adble to ensure our partners have the latest in I - ,?ice.�s:.,,;.� •t• °" ;,:;; �. solar Innovation. Module product workmanship warranty - '25 years** 30 years NORTH AMERICAN QUALITY a 97%end of 1"year Linear power performance guarantee z 90%end of 12�year R 5llfabIs the largest and most automated z82%endo1`251^year B solar manufacturer in North America. z 80%end of 30^year Utilizing premium quality materials and -•r Strict quality control management t0 deliver ULC ORD C1703,UL 1703'IEC 61215,IEC 61730.1 and IEC 61730-2 Certified. s the highest efficiency,premium quality PV Product FSEC and CEC listed.IEC 62716 Ammonia Corrosion,IEC 61701:2011 modules 100%made in North America. salt Mist corrosion Certified � -• __'_ T UL Fire Ratiny: e,2 LType 1 on request) Factory ` IS09001:2015 - a •Pleaserefer mthe Safety antl Installation Manual far mounting lt[onscadpne ••12yearextendable to so years subject:to registration and conditions outlined under ^Narranty'at www.silfabsolar.com. A Warning:Read the Installation and User Manual before handling installing and operating modules. • 0• 'I 0 Thlyd-party generated pan flex from a•s1 :iSModules Per Pallet:26 Fraunhofer-Instltute for Solar Energy f .J� 1Ei Pallets Per Truck:36 0 _ -• - aE'II i• _ .II Systems JSE are available for download at: iR Modules Per Truck:936 "010XIO°aOi I dfabsolar.com/downloads �� 8 I 3 11• • 0 - ^4i; 511(ab Solar Inc. b 240 Courtneypa rk Drive East � _ Mississauga ON LSTI Canada � ••- SllfaC a Tel*1 905-255-2501 1 Fax+1905-696-0267 �: - E•. Info@sll(absolar.com I wwwsllfabsolar.com y'•°^•^^° > ^+••• 5 falb Solar Inc. ■0©® 800 Cornwell Ave 3 Bellingham WA 98225 USA Tel*1 360-5694733 / Power Optimizer } For North America Power O pti m' izer' O P320/P340/P370/P400/P405/P505 P370 P400 P505 1''For North America x h (for high— (for 12 11 if P, (for higher (typical module (for power l3c�c.11 7'2r cell or 'u rc.t P320/P340/P370/P400/P405/P505 mINPUT , - Rated Input DC Pd-P 320 340 370 400 405 1 505 w Absolute Maximum Input whage 48 60 80 125a 83m we Dec at lowest temperature) IAPPI Operating Range B-48 8-6D 8-80 12.5-105 12.5-83 we Maximum Short Gran Cu Trent 11 W1 14 Add I (Isc) f'3 T Maxunum DC Input Current 13.75 12.63 17.5 Adc 3' v Maximum EHicency 99.5 % Weghted Efficiency 98.8 98.6 % Overvonage Catdgi 8 ICI OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) 7 Maximum Ou put C enl 5 Atic S Maxmum Output whage 60 85 we 'OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE 'EIS, INVERTER OFF N safety o,tput whage ver 1 z D.1 we rower output r STANDARD COMPLIANCE EMC FCC Partly Class 8,IEC61000-6-2,IEC61000-6-3 Safety IECU109.1(class ll safety),U1.1741 RoHS 4s INSTALLATION SPECIFICATIONS Maximum Allow d System 100D we whage Compatible mveneis All Scla,Edge Single Phase and Three Phase inverters Dimensions(Wx L.M 128 x 152 x 28/5 x 5.97 x 1.1 128x 152x36/ 128,152 x50/ 128x 152.59/ tutu/in s x5.97x1.42 5x5.97x1.96 5,5.97 x 2.32 Weight(including cables) 630/141 750/17 1 845/1.9 106,1 2.3 gr/lb Input Connecor MC4'n Output Wire Type/Connector Double Insuli MC4 Output Wm Length 0.95/30 1.2/3.9 T/h Input wire Length O.lfi/0.52 m/!t Operating Temperatum Range -40-.85/-40-.185 'C/T PV power optimization at the module-level Protec9on Rating IP68/NEMA6P Relaeve Humldty 0-100 % arwretl sre w.xerama mpe�a.mpepm w ap m.s�pam:r miermiee mloaee urrvEe zv17 mgulres max Inpptvdlage be na rmrc man epv / Specifically designed to work with SolarEdge if Fast installation with a single bolt �wrpmerepnnra�rrypmPeaseKpnm�som�Ecpa inverters / Next generation maintenance with module- / Up to 25%more energy level monitoring D E P320,P340,P370, Minimum String Length P400 8 10 18 / Superior efficiency(99.5%) / Meets NEC requirements for arc fault (P.—opbmvers) pws/Pros fi s 4 protection(AFCI)and Photovoltaic Rapid Maximum Whig Length 21 2s so. / Mitigates all types of module mismatch losses, Shutdown System(PVRSS) roweropnmaers) s7ooc6omwm from manufacturing tolerance to partial Maximum Power"String SE7500-US-SE11400- 5250 6000a IN- W shadin US) 9 / Module-level voltage shutdown for installer ParalklsvingsofDererenlLenglhs and firefighter safety or onenramna 1e: / Flexible system design for maximum space „Eprtlmaxa:m reniz npa anw.eemaml.viosos tub P3lam;�ic omommrs9es/eara�lvfilevsainys�n�yirc pot utilization amng wim mprc man]a opomper:ape:no<meet NEe rape mmap„n rc9p.iemerta mnh vamge wu ce am:<nK 1gv rc9piremmt m Eo'SE1ddKUS/SEd32I. nis allwretlmInmEupmfi5ggwpermn9 whenJsmogsare¢nnxmd mmeImener I3 smogs perunrtkrSEd)1KU5)one sMen ce maximpm pp,.er eserenre Ee<ween me stnn9s is up m logow im Em SE30KUShEJJ JKJSrSEE6GNSKEIMKUS,n s allwretl m intuit up m 15.iHgW per smngwnen 1 smogs are mnnectee m me inserter(3 smogs per um mr SE66fiKU5/SESggKUS) ono when me mammpm pp„ertldmrenu 6nwern me sal�gs s pp m zopow solaredge.com solar® ® ® 3. �rt. m p rt�Mr. 4x Eu��� � m ...... weMa � K�, m�rm aa4�.emi�.r,rK CE ROHS / Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/ Single Phase Inverter Z SE760OH-US/SE10000H-US/SE1140OH-US ex, :x, eer xx, er xrex .ee with HD-Wave'Technology rCn OUTPUT 38W @ 240V 6000 @ 24oV 11400 @ 240V Rated AC Power Output 3tYJ0 SOW 76W 100W VA 33W @208V SWO@WeV 1lXIW@208V Maximum AC Power Output 30W 38Co @ 240V 5W0 6000 @ 240V 7� 10000 114W @ 240V VA for North America 3300@208V SOW@WSV 1WW@208V AC ORput W Rage Min:Nom:Max. V V V Vzc SE3000H-US/SE380OH-US/SE5000H-US j SE6000H-US/ (211-240-264) AC Output Wltage Min:Nom:Max. V V Uac SE760OH-US/SE1000OH-US/SE1140OH-US U83-2oa-229) m AC Frequency(Nom-0 59.3-60-60.5w Hz Maximum Continuous oumut 125 16 21 25 32 42 4].5 A _ Current @240V Maximum Continuous Output - 16 - 24 - - 40.5 A Current @208V A GFDI Threshold 1 A ^"_^• -^^^^—_ -^-^'-•-�^-� - f V Jal Wniiarmg,Islanding 10+'oalary2 }{J Oj Proe'on,CounVyCon(guraba yes Thresholds INPUT U� Maximum DC Power @240V 4650 59W 7750 93W 118W 15500 17650 W I' -- I - ---' '--•---_.� 1 Maximum DC Power @08V - 51W 7750 - 155W W F4�,O _�� O� ��i- ',r iransknner-less.Ungmunded Yes Maximum Input Wkage 480 WC Nommal DC Input Voltage 3130 400 We _- Maximum Input Current@240Vw 6.5 10.5 13.5 165 20 27 30.5 Adc O O Maximum Input Current@208W 9 1 - 13.5 - - 27 Ad, �--J-..•.*�.^>.:.... .......�.....,_.,...,,,_,.,.._„ -a-�++.�+1Y.-m��.+ ewe.,..«...+�'�.. Max.Input Short Cirwit Current 45 Adc •OI .L- ®� Reserse-Polarity RnpWaan 14s O n1 l3 r Ground-Fault lsolabon Deplbn M.Sen,itWy Ma—um Inverter Efioenq 99 99.2 % 99@240V CEC Weighty ElLdenry 99 % Nghmme Power Cnnsump[bn a2.5 W ADDITIONAL FEATURES Supported Communiceton Interfaces RS485,Ethernet Ziig a(optbnal),Cellular(optionai) Revenue Grade Data.ANSI CUM OpponaP° Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Gnd Disconnen Optimized installation with HD-Wave technology 2017690.12 STANDARD COMPLIANCE sappy UL1741,UL1741 SA,UL16990,CSA C22.2,Canadian AFCI ao:ordng to TI.L.M-07 Specifically designed to work with ® Extremely small G,id Conneabn Standa,e, EEE150,Role 21,R.1,14 e118 power optimizers E."'.., FCC Pat 15 Cb,,a B Record-breaking efficiency / Built-in module-level monitoring INSTALLATION SPECIFICATIONS AC Output Condut See/AWG 3/4'mimmum/14-6 AWG 3/4'minimum/14-4 AWG Pange a/ Fixed voltage inverterfor longer strings / Outdoor and indoor installation DC Input Conduit Size/a of Strings/ 3/4'minimum/1-2 rings/t4-6 AWG 3/d'minimum/1-34rings/14-6 AWG AWG Range Dimensions vnth Safely Switch 17.7x14.6x6.8/450x370x174 21.3 x 14.6 x 7.3/540 x 370 x 195 if Integrated arc fault protection and rapid shutdown for® Optional:Revenue grade data,ANSI C12.20 (H.W0) NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) weight v4th Sakty Switrn 22110 1 25.1/11.4 25.2/11.9 38.8117.6 Ib/kg Noise a 25 1 <50 dRA a/ UL1741 SA certified,for CPUC Rule 21 grid cooling Natural Cenveainn compliance Operating Temperature Range -401,.140/-25 to.fD'e(-40'F/-aTC opt )m 'F/Y Prote..n Rating NEMA IX(1—nar with Safety Switch) :°Fa oNer reglw,sl sebrgi please mntxt SplarEb9e vpPwt solar Anlgner elwurco P/py N SEsetlnerme rwi011mnl Inputs remmNe lueraareE sclaredge.com ;, Flip gatle In nerPN SE vH-USWONNQ ��Pwp�rnavnv'sE�x:,°H usoporvNwm:nlma/nw.wsphred9e mm74re,/aeraplpTlwse.ran+pe,an�reaemo°9-npm-na ptll ROHS nr ot ik V --•�►�' - < **�`ys '. Nk°f ,,� � �- i''.n � ' "' ,.'yam o""'4•w j '.A.�'r' rs°'E4'1 ? '�' ,n' �� �; r' �Y �d .'' >` i - � �� �„�.�{t'"- a ��� m �"+'�, x.. '�,.w., .. 3- a°"�'E � �'� �, ': i'�• ' Y" �. 7 } dry. �' ,. vyyj., -.•- rr`P +w� g r 7 aP'" ''" 'y a'� .. S� n` ','bp • .9 ?f'j aR�'1W il�! I a', .'�a�`�J'`1,��-"., '•'moo .�e' "*.,� �.�� � �� „'!F. ,ay 44 "�N,�jn,..�gl�^"Rj'',iZ;'.���•w�*ify� � ��� t'��iP` � �k' ''