HomeMy WebLinkAbout19-21901 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 21901
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
.,PERMIT INFORMATION LOCATION INFORMATION
Permit#:21901 Issued: 10/24/2019 Address: 3275 LYTTON HALL DR
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 226,201.20 Total Fees: 18,171.47 Subdivision: HIDDEN RIVER
Amount Paid: 18,171.47 Date Paid: 10/24/2019 Parcel Number: 24-26-21-0110-00000-1370
CONTRACTOR INFORMATION. OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA, FL 33607-5995
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,008 SQ FT
APPLICATION FEES .
PL B G FEE 176.25 SEWER CONNECTION RESIDEN- 2,090.00 ELECTRICAL FEE 264.38
WATER CONNECTION RESIDEN] 1,010.00 MECHANICAL FEE 123.38 SCHOOL IMPACT FEE-sfr/1% 77.28
SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68
BUILDING FEE 1,273.49 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 WATER METER RES 3/4" 473.78 PARK FEES SF 769.56
vq,;�l q 9
Inspections Required
FOOTER 2 D R U PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult.with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
oup &__ f"�*
N RS SIGNATURE PERMIT OFF]
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting 913 363 2891
owner's Name Lennar Homes,LLC Owner Phone Number r813.574.5700
Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number F
Fee Simple Titleholder Address N/A
1 JOB ADDRESS [3275 Lytton Hall Drive LOT# 1370
SUBDIVISION Hidden River Phase 2 PARCEL ID#1 24-26-214110-00000-1370
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR e ADDIALT SIGN' Q DEMOLISH
P INSTALL REPAIR
PROPOSED USE SFR 0 COMM OTHER
TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL
DESCRIPTION OF WORK Single Family Residence I Pool/Screen Enclosure/Fence
BUILDING SIZE I U/R IF 20=08 SQ FOOTAGE1555 HEIGHT 1 Story
BUILDING 1$gq0(0j�) VALUATION OF TOTAL CONSTRUCTION
1.
OELECTRICAL 1$ AMP SERVICE FYI PROGRESSENERGY W.R.E.C.
OPLUMBING 1$ q0
MECHANICAL 1$ VALUATION OF MECHANICAL tNsTALLATION
=GAS ROOFING 0 SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do
11-4-4-4.4-11-1 . . . . . . . . . . . . . . . . .
BUILDER COMPANY Lermar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4600 W.Cypress St.Ste.200,Tan/pa,FL 3)607 License# I CGC1518166
ELECTRICIAN COMPANY =Edmon,son Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN
I
Address 1034 Skipper Road,Tampa, Ft 331Y(3 License# I EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc__
SIGNATURE REGISTERED Y/ N FEE CURREN LY LN
Address P.O. Box 5308, Bayonet, FL 3467416308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, FL 3467H-5308 I License# I CAC058062
OTHER COMPANY C St4ling Quality Roofing, Inc
SIGNATURE REGISTERED Y PN FEE CURREN I Y/N
Address 14211 Shoal Line Blvd, Spring Hill, FL 34607 License# I CCCO57991
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Constrktion Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R70-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construddri Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . . . . . . . . . . .
II .tit;t Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law', moth the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired,a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior, to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement'.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable Paws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work sand installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and';that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of,other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must;fake to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,IDocks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply'to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in!,Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be'used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning,i;gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes;-nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building!Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDItR OR AN ATTORNEY BEFORE RECORDING YOUR NQTICE,0F COMMENCEMENT.
FLORIDA JURAT(F.S. 7. )
OWNER OR AGEN aVh� CONTRACTO
Subscribed and swo a ed) efora me this Subscribed an orn to(or affirmed)before me this
LJ'Huy" y by Ash ee Callahan I 23-Aug-19 by Ashlee Callahan
Who is/are personally known to me or Who is/are personally known to me or hasihave prod e '
s identification. as identification.
Notary Public Notary Public
Commission No. FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
— '� Ftl��,kN:.lHDltE�sl'I
.-�'•.. f~EIf✓`�.4H.E`101k�gllpl +a
i kiCvrr0f.'3IValzur +• ai�'ln.lYilLttfllMnhAG4f)7x
5MIMIII�`iifii yrdl�Q }
Haaielbut,�r+atu`yt�A,ia®3,�Ip
,laps C+ idti,t. �tatuRn����sa�Mill '
f
PASCO COUNTY, FLORIDA
Pbt'ttltNo. 2 (�
�\ Date Petmltted
Builder Name/Owner Name 140 jd, a4lj *)2L S Control#
County Pe[cei No. / SutaDiv:
Address/Location c3Z 1'7
p
Classi8catlon/Type of USQ !
TRANSPORTATION IMPACT FEE te: Sq.Ft Unit; 240CS
Exempt ❑Yes O No Haw Determined
b
Impact Fes Amount $.�&tG3z,Uu Zone No. TAZ: i
i
SCHOOL IMPACT FEE i
Account (0$8) Single•Famlly Detached House Amount $_ 1/ w
(067) Mobile Home
(058) Other Residential
123) Collection Fee .
Exempt 0 Yes ❑No How Determined
PARKS AND RECREATION FEE
{ Land Account Land Credit Land Total
Recreation Account Recreation Credit .Recreation Total j
Zone TOTAL AMOUNT $ 7to9�Jio
Exempt ❑Yes (3 No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility.Account Facility Credit Facility Total
Exempt ❑Yes ❑No Haw Determined Total Amount i
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Chocked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL.INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICEOF PASCO COUNTY
Aokn0W1edgamantbelow dose not imply acceptance of concurrence,but almply recolpt of a copy of thle form,placing
the buitdtng permit owner an notics of Uits assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
- h
INSTR# 2019179345 BK 9992 PG 2967
10/21/2019 01:33pm Page 1 of 1
Rcpt: 2101199 Rec: 10.00
DS: 0.00 IT: 0.00
Nikki Alvarez—Sowles, Esq:
Pasco County Clerk & Comptroller
Permit No. Parcel ID No 24-26-21-0110-00000-1370
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE 2 PB 79 PGS 102-110 LOT 137
Street Address: _3275 Lytton Hall Drive Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. owner Information: Lennar Homes, LLC.
Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(If other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: 813.574.5700
5. Surety: N/A
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes. LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OFF PINEL �
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 23 day of August f01 I by
Steve Robert Smith as Vice President (type of autho' officer,trustee,attorney in fact)for
Lennar Homes. LLC (name of p on b hom instrument was executed).
Personally Known OR Produced Identification❑ Notary Signatu
Type of Identification Produced Name(Print) .Ellssa lInflerfavn
Verification pursuant to Section 92.525;Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
ELISSAM.HOLLERAN Signature of Natural Person Signing Above
Cemm11e100 FF 885837
Ex'Ires June 8,2020
wpdata/bcs/bcs form: '. endrlThru7royFelnlMunna100,10.57010
V�
STATE OF FLORIDA, COUNTY OF PASCO ��.�
THIS IS TO CERTIFY THAT THE FOREGOING IS A
TRUE AND CORRECT COPY OF THE DOCUMENT
ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
lfa:r►:.r..
WITNESS MY HAND AND OFFICIAL SEAL THIS Tit yn f We7*Est
4 DAY OF 2�q
C COMPTROLLERS,;
GY DEPUTY CLERK ire, OF
� �� �
24-26-21-0110-00000-1370 1 Pasco County Property Appraiser Page 1 of 1
Parcel ID 24-26-21-0110-00000-1370 (Card: 1 of 1)
Classification 00000-Vacant
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $11,016
TAMPA , FL 33607-5995 Building $0
Extra Features $0
Physical Address
3275 LYTTON HALL DRIVE,
ZEPHYRHILLS, FL 33540 lust Value $11,016
Assessed (Non-School Amendment 1) $11,016
Legal Description (First 200
characters)
HIDDEN RIVER PHASE 2 PB 79 PG Non-School Taxable Value $11,016
102 LOT 137 School District Taxable Value $11,016
Jurisdiction
CITY OF ZEPHYRHILLS
_ Land Detail (Card: 1 of 1)
Line Code Description IZoning,Uni s Type Price Condition IVaue
1 0100V LP1-1 SFR MPUD 16,000.00 SF_ $4.50 0.40 $10,800
2 0100V i LP1-2 SFR I MPUD 600.00 SF ] $0.90 0.40 $216
Additional Land Information
Acres Tax Area �—FEMA Code Res Code Com Code Condo Code
0.15 30ZH -- HDRV LLD HDRV
Building Information (Card: 1 of 1)
Unimproved Parcel
__ Des Extra Features (Card: 1 of 1)
Line Code cription IYear Units Value
No Extra Features
Sales History
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year _Book/Page Type W DOR Code Condition Amount
01/2019 9854 / 3547___ Warranty Deed 05 Vacant $4,965,000
09/2011 i 8606 / 3376 Warranty Deed 05 Vacant $0
06/2010 8360 / 1872 v1 Certificate of Title 12 Vacant $0
_ 12/2005 ( 6748 / 0894 Warranty Deed____ _ Vacant _ $0
6 47 8
_ 12/2005 0891 ^_ Warranty Deed �i Vacant $0
12/2005 —; 6748 / 0889 Warranty Deed Vacant $0
http://search.pascopa.com/parcel.aspx?parcel=2126240110000001370 10/14/2019
D
0
i
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401:3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4: Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. All 4 sides of drive_ way thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8: All A.D.A. requirements shall be met.
9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and
approval first.
W. All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation).
.
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303A of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.4
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313 J of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C:
17. All means of egress are.to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced.
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25: R403.5.3Hot water pipe insulation
Insulation for hot water pipe with a minim urn thermal resistance (R-value) of R-3 shall be applied to the
following:
Piping,j; inch (19.1 mm) and larger in nominal diameter,
Piping serving more than.one dwelling unit.
Piping located outside the conditioned space.
Piping from the:water heater to a distribution manifold.
Piping located under a floor slab.
Buried in piping.
Supply and return piping in recirculation systems other than demand recirculation systems.
25. Blower door test shall be provided before C.O.
26.A copy of the enery eacls shall be with uermit at all times
27. Copy of final insulation repoit shall be provided with Permit before rinaL
28. No fence,pool or screen enclosure .is issued with-this permit
F.F.E.-Finished Floor Elevation
RB.C-Florida Building Code 6 b Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
E.-QR
IFF EL 3 R FFiEL I I F E
76.20 I f 51,
1132 IFF EL A
76.80 F A I "A
A 317 318 319
IIV I IR 32,
(2- 'B ----- --' - � �' l' .
IFF EL
133 A
— ————— 284\M"—M/
Fr-Ell.
IyI 134
J�F
g5
EL FP
HJ 8 -1625
11-1-1 2 3'W-?
Ilk A
LL FF I
135 7530
i } r'
ALI
FF EL
2 75,05
FF EL
J, 75.10
Ilm- 136 3o
\ L6
t
A
FFi i It
28 74,8$
A
'131MMA
MOM
74.85/
\
FF EL280 N
138,
A
EL 1.111,
27 7445
FF EL
cp
139 74.40 1--
J
L'k
277
FF EL27
S/ 1 / 276
140 74.20 A
A
FFr:L
A p 7115
A
- - ----- - - -
II p
FFF EL7
141
A
PLOT PLAN' SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E.
NOT A BOUNDARY SURVEY
LOT 137 BEARING BASIS:
HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00'23'02" E
PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND
PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS N NOTES TAKE PREFERENCE.
THIS PLAN IS FOR PERMITTING PURPOSES LOT =--A6-00I-DDsa. FT. ALL DATA SHOWN HEREON BASED ON THE
ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =15-5-0--SQ. FT. ENGINEERING PLANS OF KIMLEY-HORN AND
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 45 __so. FT. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES.
GARAGE = 406 SQ. FT. II
LEGEND: COVERED LANAI = NZA 0. FT.
-^AA,— = PROPOSED DRAINAGE FLOW PATIO = 23 —SO. FT, 10' UTILITY EASEMENT
(00.00) = PROPOSED GRADE CONC. DRIVE FT.
E-00.00 = EXISTING GRADE A/C & CONC PAD = 9--SQ, FT.
PRIVATE SIDEWALK = 28
—SQ. FT.
NOTES: IMPERVIOUS = 38 __%
LOT GRADING TYPE = A = 2523 --SQ. FT.
PROPOSED PAD ELEVATION = SOD = 4077 -SO, FT.
FRONT SETBACK = 20'
SIDE SETBACK 10' OFF LOT AREA CALCULATIONS
REAR SETBACK = 10' RIGHT OF WAY - 720.00_So, FT.
DRIVE APRON = 144—SQ. FT.
PUBLIC SIDEWALK = 240 SQ. FT.
SOD - 336 --SQ. FT. ,,-PRM(P)
TOTALS PC(P)
AREA = 7320.00 SQ. FT.
DRIVEWAY = 600 SQ. FT.
SIDEWALK =--26-8SQ. FT.
SOD =--ALI—3 -SQ. FT.
ui
co
C14
LOT 136
LOT 89
r>
S 89*36'58" E 110.00' 25
:0
0 .............................. ......2. .P
q tj 0. 0' 0 0
0 to
5 4-0 C; 0
(0 a m
z
0S Ld
oz •LLJ 0 9
0
OK" 1�i2 CL Ej -0 IL ......
<
N
m td (L .�
a. LOT 88 uj 0
>0 (0, z 0
.n Of 0
z ... ........
il 35.5
LLJ z V)
3
N 89*36'58" W 110.00-
25 '
PT
BOUNDARY LOT 87 LOT 138
30
ri
Z!
PROPOSED:
LOWEST FLOOR ELEVATIONS:
LIVING AREA: 74.75'
GARAGE AREA: 74.21'
DESCRIPTION: ELEVATIONS REFERENCED TO
LOT 137, MAP OR PLAT ENTI ED IDD N RI ER PHASE 2", NATIONAL GEODETIC VERTICAL
AS RECORDED IN PLAT BOOK 07 PAG 11 THROUGH DATUM OF 1929. MEAN SEA
OH 082, OF THE PUBLIC R DSl0F PASC CO NTY, FLORIDA. LEVEL= 00.00 FT.
APPARENT FLOOD HA 'Y' tOMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 9/26/2014
1 �AkD ZONE"
zi S2,dre Feet: 6600.00:t LENNAR HOMES
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q- CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D- FOUND NAIL & DISK, FPP- FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
=REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK. TBM= TEMPORARY BENCHMARK,
U/P= UTILITY POLE, W/F- WOOD FENCE
Drawn By:
> OHN R.BEACH&ASSOCIATES,INC. SMS
C SURVEYORS AND MAPPERS Checked By:
0)
t 911 WEST ST. PETERSBURG DRIVE JRB
a ONE OLDSMAR, FLORIDA 34677
Scale:
WAY (813) 554-1276 FAX (813) 855-8370 1„
-30'
o NOT VALID WITHOUT ORIGINAL SIGNATURE jDate: PLOT PLAN 8/21/19 ACS
'rA AND THE RAISED SEAL OF A FLORIDA AT j DATE
:5- LICENSED SURVEYOR AND MAPPER tOHN R. B
.5 Revisions: FLORID77AREG. NO SURVEYOR No. 2984 LB#4493
:3 FLORIDA
M. HA-WEY
PRO NAL SURVEYOR & MAPPER No.7123
ISRald-
Lennar Homes-3275 Lytton Hall Dr:2,008 sqft
Column
SQ. FEET PRICE
MAIN OR LIVING: 2,008 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 226,201.20
FEE SHEET $ 1,175.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,273.50
ELECTRICAL: $ 264.38
PLUMBING: $ 176.25
MECHANICAL: $ 123.38
SUB-TOTAL $ 1,837.50
TOTAL $ 1,837.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,964.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,728.00
100.0% $ 7,728.00
1.0% $ 77.28
TOTAL: $ 7,805.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,171.47
PASCO COUNTY Receipt Date: 04/11/2016
BUILDING CONSTRUCTION SERVICES Receipt Number: 1919173
Pi
8731 Citizens Drive
COt�NTYIUiID Suite 230
OPEN SMM.Yraxw PLAcm New Port Richey,FL 34654
727-847-8126
** NOT A
Paid By Check# CC Auth# Cashier ID Workstation
Check 01349902 MLARNOLD
'Fee.Descrigtion ;>Amoiuiit='Paid,.
Impaa[Fee Residential Solid Waste Single Family
Total Payments: $3.42 ;
Pavor Address _- — -------_- Phone -
LENNAR
Comments:
3275 LY1T0N HALL DR
21901
24-26-21-0110-00000-1370 f(
While you will be paying your bill with Pasco County Building Construction services,the full amount of the credit card or a Elieck fees,,NOT shown above,Is collected by First
Billing payment services.
E
e1.
myreportslreportslIPASCOPRODIPASCOICustomer Receipt vlfrpt Print Date: 12/20/2019 Page 1 of 1
Jacqueline Boges
From: Joey Theel (City of Zephyrhills Support) <support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, October 30, 2019 3:27 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3275 Lytton Hall Dr by#21901
EXTERNAL EMAIL
##- Please type your reply above this line -##
Your request (#296939) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/296939
......................................... .................................................................................................................................................................................................................................................................................................................................
�= Joey Theel
I
L 11—' Oct 30, 12:26 PM MST
Sewer available and ready for the contractor/plumber to tie in.
............................................... ................................................................................... ................................................................................................................................................................................. .....................................
Jacqueline Boges
1---- Oct 30, 1 1 :32 AM MST
services 3275 Lytton Hall dr by#21901
This email is a service from City of Zephyrhills Support .
1