HomeMy WebLinkAbout19-21755 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21755 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 2.1755 Address: 38122 HENRY DR Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: ADD/ALT COMMERCIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est.Value: Parcel Number: 02-26-21-0080-OOA00-0070 Improv. Cost: 20,000.00 OWNER INFORMATION Date Issued: 9/19/2019 Name: CITY OF ZEPHYRHILLS Total Fees: 210.00 Address: 38122 HENRY DR Amount Paid: 210.00 ZEPHYRHILLS, FL. 33542 Date Paid: 9/19/2019 Phone: Work Desc: ADD 3 ERICSSON AIR& LYBRID TOWER GROUND EQUIPMENT CONTRACTORS APPLICATION FEES ERICSSON INC BUILDING FEE 210.00 l A • 5, Ins ections Required FOOTER 2 D ROUGH PLUMB MI (; INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACT IGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: Samantha Green <samantha.green@ericsson.com> Sent: Wednesday, May 20, 2020 11:28 AM To: Jacqueline Boges Cc: Steve Nichols Subject: BP Cancellation RQTA70XC110_21755 Jackie, Construction for building-permi AE17a-55�has-be ne cancelled. No work has been completed at this location. Please close out permitting and provide confirmation of the permit's cancellation. Thank you, Samantha Green 678-938-3563 1 813-780-0020 City of Zephyrhills Permit Application Fair-813-780.0021 826548/TA70XC110 Building Department Date Received r ✓ + Phone`Contact for Permitting 813 342-3873 NFL ermits crowncas0 .rom Ir � � rrr i � Owners Name Crown Castle USA,INC.for Sprint Owner Phone Number 813-342-3873 Owners Address 1 4511 N Himes Ave,Ste 210 Tampa FL 3361 Owner Phone Number Fee Simple Titleholder Name I City of Zephyrhills Owner Phone Number Fee Simple Titleholder Address 1 5335 8th St Zephyrhills,FL 33541 JOB ADDRESS 38122 Henry Dr,Zephyrhills LOT# SUBDIVISION PARCEL ID# 02-26-21-0080-OOA00-0070 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR a ADDIALT 0 SIGN 0 Q DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL Q DESCRIPTION OF WORK Proposing to add(3)Ericsson Air 6488(1 per sector)and(3)Amphenol hybrid for the BUILDING SIZE B platform %rWO&6 nges to g and spaa&lg and equipment =BUILDING $ 20,000 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS NERGY� W.R.E.C. =PLUMBING Is 1i+ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION Nk =GAS = ROOFING = SPECIALTY = OTHER FN FINISHED FLOOR ELEVATI S FLOOD ZONE AREA =YES NO BUILDER �� COMPANY ERICSSON. INC. SIGNATURE REGISTERED Y/ N FEE CURREN Ly /N Address 30 Legacy Dr. Plano TX 75024 License# CGC1518237 ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/N FEE CURM Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Address License# I I I I I I I I I t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs'd shingles Sewers Service Upgrades A/C Fences(PloUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations: TAe undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign ds the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs,wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit Is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from.the Building Official for a period not to exceed ninety(90)days and will demonstrate co justifiable cause for the extension. If work ceases for ninety(90)consecutive klays,the job is considered abandoned. pram. o WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE MMENCEMENT MAY RESULT IN YOUR $ r PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF OU ND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING IOU E OF COMMENCEMENT. # a FLORIDA JURAT(F.S.117.03) KE OWNERORAGENT CONTRACTOR N C S b_ y Scribed and swam(or a(firmVa is Subscribed and m o or armed before me this � cn z by �ht>,lin 9� � b SIT VEr7 I� NICHOLS ul sue. to Who Oa-re personalty known rg mP or has/have p� o is! e e o II t e or has/have produced w0 Ix as identification. AN as identification. U X W Notary Public Notary Public ? Commission No. `rGO 4 TS T Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped MELISSA SMART { ':= MYCO z EXPIRE&MIRY S►20 � ,�oo� Bottder111au IPu60a1JYrtterwrftets i" .:h y.._: `7`,' :°..j.,......'k..-•,M. �t.�`'i>y ' Rd.�t''z1,42cA A tis S �Yl o City of Zcphyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 0-(350y) Xc-, Date Received: 2-6- N Site: Permit Type: A4 Approved w/no comments. Approved w/the below continents: 4'Denied w/thc below comments: ❑ This comment sheet shall b ept with the permit and/or plans. Kalvin Swkzq Date Plans Examiner Contractor and/or Homeowner (Required when comments are present) 2/14/2018 02-26-21-0080-OOA00-0070 I Pasco County Property Appraiser Data Current as Of: Weekly Archive - Saturday, February 10, 2018 Parcel ID 02-26-21-0080-OOA00-0070 (Card: 001 of 001) Classification 82 - Forests, Parks, recreational areas Mailing Address Property Value CITY OF ZEPHYRHILLS Ag Land $0 5335 8TH ST Land $23,836 ZEPHYRHILLS FL 33542-4312 Building $0 Physical Address Extra Features $3,079 38122 HENRY DRIVE ZEPHYRHILLS, FL 33542 Just Value $26,915 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $26,915 See Plat for this Subdivision TYSON SUB PB 4 PG 109 POR Taxable Value $3,663 TR A DESC AS COM NE COR OF S 1/2 OF SW 1/4 TH S88DG 50MIN 15"W 1796.6 FT TH S 19.10 FT Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) _ Line ,Use Description Zoning Units Type lPrice Condition Value 1 0100 SFR 0OR4 0.12 AC $30,020.00 1.00 $3,602 2 0100 SFR 0OR4 0.38 AC 1$30,020.00 1.00 $11,408 3 0100 SFR 0OR4 0.42 I AC $30,020.00 0.70 $8,826 Additional Land Information Acres 0.92 Tax Area 30ZH FEMA X Residential Code 1ZHN.S2 Code — Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line IDescription Year Units Value 1 CLFENCE 1975 6,368 $2,866 2 PUMPHSE I 1975 240 $213 Sales History Previous Owner: N/A Month/Year 'Book/Page Type ODOR Code Condition Amount 08/1975 0806 / 0104 Vacant $0 http://search.pascopa.com/parcel.aspx?sec=02&twn=26&rng=21&sbb=0080&blk=00AOO&lot=0070&action=Submit 1/1 R 11 Date: July 22,2019 q-, FL COA#31011 1 Ryan Shaffer Tower Engineering Professionals Crown Castle 326 Tryon Road 8000 Avalon Blvd., Suite 700 Raleigh, NC 27603 Alpharetta, GA 30009 (919)661-6351 Subject: Structural Analysis Report Carrier Designation: Sprint PCS Co-Locate Carrier Site Number: TA70XC110 Carrier Site Name: TA70XC110S18.1 Crown Castle Designation: Crown Castle BU Number: 826548 Crown Castle Site Name: Pasco County(VS) Crown Castle JDE Job Number: 517876 Crown Castle Work Order Number: 1770360 Crown Castle Order Number: 449759 Rev. 2 Engineering Firm Designation: TEP Project Number: 48167.283829 Site Data: 38122 Henry Drive,Zephyrhills, Pasco County, FL 33542 Latitude 280 14'52.90", Longitude-820 11'9.40" 190 Foot-Self Supporting Tower Dear Ryan Shaffer, Tower Engineering Professionals is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above-mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC7: Proposed Equipment Configuration Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 137 mph as required by the 2017 Florida Building Code, 6th Edition.Applicable Standard references and design criteria are listed in Section 2-Analysis Criteria. Structural analysis prepared by: Madison L. Frank/ZSC Respectfully submitted by: AIWO \cEN 0 Adam M. Amortnont, P.E. ALL WORK SHALL COMPLY WITH PREVAILING No. 77387 CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE. fRHILLS STATE OF AND THE CITY OF ZEP81 5 % " 0 ORDINANCES ZORKA' # NA J 110 Jew CITY, oep�t PLAN f z July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2)ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2-Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3- Documents Provided 3.1) Analysis Method 3.2) Assumptions 4)ANALYSIS RESULTS Table 4-Section Capacity (Summary) Table 5-Tower Component Stresses vs. Capacity 4.1) Recommendations 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations AM 0 i �,,C E NSF Z` No. 77387 =_ STATE OF 0�ct` 'c4 OR10P G\�aa�\�� N / /Il I Electronic Copy tnxTower Report-version 8.0.5.0 July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 3 1) INTRODUCTION This tower is a 190-ft self supporting tower designed by Valmont Microflect. The tower has been modified per reinforcement drawings prepared by Tower Engineering Professionals in July of 2013.All information provided to TEP was assumed to be accurate and complete. 2) ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: II Wind Speed: 137 mph Exposure Category: C Topographic Factor: 1.0 Service Wind Speed: 60 mph Table 1 -Proposed Equipment Configuration Center. Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size(in) (ft) 3 Ericsson 800MHz SMR Filter 3 Ericsson RRUS 11 150.0 3 Ericsson RRUS 31 B25 148.0 (— 9 -- RFS Celwave ACU-A20-N 3 1-1/4 3 Ericsson Air 6488 B41 w/Mount Pipe 149.0 3 RFS Celwave APXVERRI 8-C w/Mount Pipe 148.0 3 Site Pro 1 VFA12-HD-SPT j Table 2-Other Considered Equipment Center Number Number Feed of Mounting, Line Antenna Antenna Model of Feed Line Level (ft) Elevation Manufacturer (ft) Antennas Lines-. Size(in), - 4.__...._.. ... ......... . ... _ .._...__..._.-..._ _. . . . _......i Cellmax CMA-BDHH/6521/E0-6 ` ( Technologies w/Mount Pipe 4 Commscope FFHH-65C-R3 w/Mount Pipe 3 Nokia AEHC w/Mount Pipe 1 1-1/2 190.0 194.0 4 Nokia AHLOA 1 1-3/5 8 Nokia AHFIB I 12 i 1-5/8 1 Commscope HCS 2.0 Part 1 1 Raycap RNSNDC-7771-PF-48 190.0 1 Tower Mounts Platform Mount[LP 102-1] I tnxTower Report-version 8.0.5.0 July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 4 - Center Number Number, Feed Mounting Line :Antenna. Line. Level(ft) Elevation Manufacturer MY Antennas Lines Size(in) DBXNH-6565B-R2M 3 Andrew Mount Pipe � � I 1 NNHH-65B-R4_CCIV2 6 Commscop a w/Mount Pipe_ � 3 Commscope SBJAH4-1 D65B-DL r F w/Mount Pipe 3 Andrew E15S09P78 175.0 3 Ericsson -RRUS 32 { 3 Ericsson RRUS 32 B2 3 5/16 3 Ericsson RRUS 32 B66 ( 3 3/8 171.0 3 Ericsson RRUS 4449 B5/1312 6 ( 3/4 �— 3 -' Ericsson RRUS 4478 B14_CCIV2 ( 12 j 1�5/8 6 Raycap DC2-48-60-0-9E 2 Raycap DC6-48-60-18-8C ! 1 Raycap DC6-48-60-18-8F ' I - I 3 Site Pro 1 Puck 3 Kenwood T1326KT12 Tie Back 171.0 3 Site Pro 1 SFS-V Stabilizer Kit i 6 Generic 2-7/8"OD x 8' Mount Pipe i + 1 Tower Mounts Sector Mount[SM 503-3] t i 3 CSS CAP-FRO-656 w/Mount Pipe j 6 JMA Wireless MX06FRO860-02 w/Mount Pipe 160.0 160.0 6 Ericsson RRUS 32 1 1-1/4 12 1-5/8 1 Raycap RRFDC-3315-PF-48 3 Site Pro 1 VFA14-HD 3 KMW HB-X-AW-23-33-OOT ( I 140.0 140.0 Communications ; 6 1-5/8 I Tower Mounts Sector Mount[SM 402-3] 3) ANALYSIS PROCEDURE Table 3-Documents Provided Document Remarks Reference- Source Geotechnical Report Nodarse &Associates, Inc. 3497292 CCISites Tower Foundation Drawings Valmont Microflect 3497291 CCISites Tower Manufacturer Drawings Valmont Microflect 3675014 CCISites Tower Reinforcement Drawings Tower Engineering Professionals 3946359 CCISites Post-Modification Inspection Tower Engineering Professionals 4460699 CCISites tnxTower Report-version 8.0.5.0 July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 5 3.1) Analysis Method tnxTower (version 8.0.5.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) The tower and foundation were built and maintained in accordance with the manufacturer's specification. 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2, and the referenced drawings. 3) All tower components are in sufficient condition to carry their full design capacity. 4) Serviceability with respect to antenna twist, tilt, roll, or lateral translation, is not checked and is left to the carrier or tower owner to ensure conformance. 5) All antenna mounts and mounting hardware are structurally sufficient to carry the full design capacity requirements of appurtenance wind area and weight as provided by the original manufacturer specifications. It is the carrier's responsibility to ensure compliance to the structural limitations of the existing and/or proposed antenna mounts. TEP did not perform a site visit to verify the size, condition or capacity of the antenna mounts and did not analyze antennas supporting mounts as part of this structural analysis report. 6) When applicable, the effective projected area (EPA) of appurtenances was determined by computation fluid dynamics(CFD)testing performed by Crown Castle. TEP assumes the means and methods used to determine the EPA's yields results that follow the intent of TIA-222-H and are accurate and complete. 7) The following material grades were assumed: a) Tower Legs:ASTM A53-B-46 b) Tower Bracing:ASTM A36 c) Anchor Rods:ASTM A615-75 8) The existing base plate grout was not considered in this analysis. 9) TEP assumed the soil properties for the bottom layer of caisson from 40-ft to 42-ft to match the properties of soil layer above. This analysis may be affected if any assumptions are not valid or have been made in error. Tower Engineering Professionals should be notified to determine the effect on the structural integrity of the tower. 4)ANALYSIS RESULTS Table 4-Section Capacity(Summary) Section Elevation(ft) Component Type Size Critical, P(Ib) . �Pom(Ib) °�° Pass/Fail No. Element Capacity . T1 190 180 Leg Pipe 2.5 STD 2 -17571 56559 31.1 Pass T2 180-160 Leg PIPE 3.5 STD ! 21 -69472 j 101716 68.3 Pass T3 160-140 Leg Pipe 5 STD i 51 I -133919 ( 165270 81.0 Pass T4 140-120 Leg Pipe 8 STD 75 I -205737 1347310 59.2 Pass T5 120-113.333 Leg Pipe 8 STD 99 -229038 347310 65.9 Pass T6 113.333- Leg Pipe 8 STD i 111 -252610 347310 72.7 Pass 106.667 T7 i 106.667-100 Leg Pipe 8 STD 120 -274177 347310 78.9 Pass T8 100-80 Leg Pipe 10 STD(SCH40) 1 129 -336355 484378 69.4 Pass T9 80-70 Leg Pipe 10 STD(SCH40) I 147 i 369915 € 484378 76.4 Pass T10 70-60 Leg Pipe 10 STD(SCH40) ! 159 403034 484378 83.2 ._ Pass T11 60 40 Leg Pipe 12 STD 168 470040 ' 602433 78.0 Pass tnxTower Report-version 8.0.5.0 July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 6 Section � Critical' Elevation(ft) Component Type Size ' P(lb) OPauow(lb) Pass/Fail " No.. Element Capacity_ = T12 40 30 I Leg Pipe 12 STD 186 -503079 602433 83.5 Pass I T13 30-20 Leg Pipe 12 STD 198 1 -535678 602433 88.9 Pass T14 20-0 Leg Pipe 12 XH 207 i -601377 794335 75.7 Pass T1 I 190-180 Diagonal Li 3/4x1 3/43/16 8 I -4397 8758 50.2 Pass T2 180-160 Diagonal L2x2x3/16 27 -8657 12785 67.7 Pass 1 I I F74.1 (b) T3 I 160-140 Diagonal 21-2 1/2x2 1/2x3/16x3/8 58 -12126 52593 23.1 Pass 59.4(b) T4 140-120 Diagonal i L3x3x3/16 84 I -12644 22202 57.0 Pass J 76.9(b) T5 1120-113.333 Diagonal L3x3x3/16 108 -12912 21099 61.2 Pass 78.5(b) T6 113.333- Diagonal L3x3x3/16 117 -12830 19950 64.3 Pass 106.667 80.2(b) T7 106.667-100 Diagonal 2L3x3x3/16x1/2 126 14442 61700 23.4 Pass 43.6(b) T8 100-80 Diagonal L3 1/2x3 1/2x1/4 138 -16971 27303 62.2 Pass 64.0(b) FT9 ( 80-70 Diagonal L3 1/2x3 1/2x1/4 I 156 F:i-63571 25401 64.4 Pass 66.0(b) T10 70-60 Diagonal 21-3 1/2x3 1/2x1/4x1/2 165 -18615 89019 20.9 Pass 37.5(b) T11 60-40 Diagonal I L3 1/2x3 1/2x3/8 177 -19425 30929 62.8 Pass T12 I 40-30 Diagonal L3 1/2x3 1/2x3/8 195 -18445 29065 63.5 Pass T13 30-20 Diagonal 21-3 1/2x3 1/2x3/8x1/2 204 -21447 [-ii0283 19.4 Pass 29.8(b) j T14 ( 20-0 Diagonal L4x4x3/8 216 -21780 35179 61.9 Pass j T1 190-180 Top Girt L3 1/2x3 1/2x1/4 6 -1851 1 29785 6.2 Pass 21.1 (b) T2 180-160 Top Girt L3 1/2x3 1/2x1/4 23 44 [--E541 0.2 Pass 0.6(b) T3 I 160-140 Top Girt L3 1/2x3 1/2x3/8 52 291 73715 0.4 Pass i i 1.5(b) T4 140 120 Top Girt L3 1/2x3 1/2x3/8 76 I 2635 30403 8.7 Pass i { I 22.4(b) I T5 120-113.333 Top Girt L4x4x3/8 100 -2088 34432 6.1 Pass j 16.8(b) T8 100-80 Top Girt ! L4x4x3/8 130 -4063 25694 15.8 Pass 22.6(b) T9 80-70 Top Girt L5x5x5/16 148 -4225 I 34145 12.4 Pass 33.0(b) T11 60-40 Top Girt L5x5x5/16 169 -5713 27177 21.0 Pass 37.0(b) T12 40-30 Top Girt L5x5x5/16 187 5364 22493 23.8 Pass j .34.7(b) T14 20-0 Top Girt f L5x5x5/16 I 208 I -5614 P589 30.( Pass i ` 36.9 b) Summary I Leg(T13) 88.9 Pass I I Diagonal 80.2 Pass I ( (T6) i To Girt 37.0 Pass �(T11) Bolt 80.2 Pass j Checks i IRATING= 88.9 Pass tnxTower Report-version 8.0.5.0 July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 7 Table 5-Tower Component Stresses vs. Capacity- LC7 Notes Component Elevation (ft) %Capacity, Pass/Fail , �1,2 Anchor Rods - 59.5 Pass 1,2 Base Foundation Soil Interaction - 71.5 Pass i1,2 _ Base Foundation Structural - 26.2 Pass Structure Rating (max from all components)= 88.9% Notes: 1) See additional documentation in"Appendix C-Additional Calculations"for calculations supporting the%capacity listed. 2) Rating per TIA-222-H Section 15.5 4.1) Recommendations 1) If the load differs from that described in Tables 1 and 2 of this report,the referenced drawings, or the provisions of this analysis are found to be invalid, another structural analysis should be performed. 2) The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. tnxTower Report-version 8.0.5.0 July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 8 APPENDIX A TNXTOWER OUTPUT tnxTower Report-version 8.0.5.0 190_0 fl p I i I i N i I a l i I DESIGNED APPURTENANCE LOADING 180.0 tt _ ELEVATION__._..._ TVPE ELEVATION C i CMA-BDHH/6521/C-0.6 w/Mount Pipe 1190 _- DC2d 10-0-9E -- i ® I I CMA-BDHH/6521/E0.6 w/Mound Roo I190 DC2d8-600-9E 171 p o • I I MAABDH60. /Mwt Pipe 190 (2)29'Da x e'Pip 171 CM 621 El 22.6 w Mount Pipe 190 (2)29'Dia x B'Pipe 1 I ( e I IFFHH-65C.R3 w/"M Pipe 190 ------1 � (2)29'Dia x B'Pipe 17711 FFHH-65C-R1 w/Maid Frye 1190 2.4'Dia x 12-tt Pipe _- 17 �H-65C-R3 w!Mou�R Frye 1190 24'Dla x 12-h Pipe Nil I FFHH-65C•R3 w/MwM Pipe 1,90 2.4'Dla x 12-R Plpe 1 171 160.0 tt AEHC W Mount Pipe 1190 (2)l2 12x212xU4.4W 171 AEHC w/Mant Prye 190 (2)L2 12x21/W/4 x 4W 171 I ' AEHC w/Mount Pipe (2)L2 IM212414 x 4'4• 171 l31 AHLOA 1190 sw w MoW ISM sm3 31 1171 ! m ! AHLOA :190 CAP.FRO-656 W Mount Prye 1160 1(2)AHFIB 1190 CAP.FROE56 W M-1 Pipe 160 n !190 AHFI9 1190 (2)M%06FR0860-02 w/Mount Pipe 160cz -_------ AHFIB 190 (2)MX06FRO86R02 w/M.rd Pipe 160 (2)AHFIB 1190 (2)MX06FRO86042 W Mound Pipe 160 HCS 2.0 Pert 1 1190 -_(2)RRUS 32 160 _ 140_0 tl RNSNDC-T771-PF48 190 I� ) . - 190 (2)RRUS 32 160 (4 24•x 4-tt pipe (2)RRUS 32 160 (4)24'x Ftt pipe 1190 RRFDC-3315-PF-08 160 II (4)2.4•x Ftt pipe 190 24•Dia x 6-R 160 io 24•Da x 6-ft Pipe 1 190 24•Dia x 6-k 160 1 8'Ladder 190 24•Dia x 6-R 160 w It P]Mt-Mount[LP 102-11 190 Site No 1 VFA14-HD 160 DBXNM-65656-R2Mw/Mourrt Ape -__171 Ste Prpl VFA14-HD 160 _ i DBXNH-6565E-R2M w/M.aW Pipe 171 &a No 1 VFA14-HD 160 p DB%NH-6565B412M W Mom Pipe 1171 APXVERRI8-Cw/Mourd PW 148 120.0tt SBJAM4-1 D65&DL w/Mamt N" t71 APXVERR18-Cw/Mwud Pipe 148 SadAH4.1 D65B-DL w/Mount Rpe 171 AP%VERRIB-Cw/Mount Pipe US . i SaJAH4.1 D65B-DLw/Mo t Pipe 1171 AIR 6488 B41 w/M-M Pipe 148 X (2)NNHH-65B-R4-CCIV2 wl Mont Rpe 1171 AW 6488 B61 w/Mount Pipe 148 1133 tt i (2)NNHH-65B-R4 CCN2 W Mp Pipe 171 AIR 6488 641 w/Mount Pipe 148 (2)NNHH-65B-R4-CCIV2 w/Mo-d Pipe 1171 RRUS 31 B25 /48 E75$09P78 1171 RRUS 31 B25 148 106.7 tt (2)E15S09P78 171 RRUS 31 825 148 2: I DC2.48•60-0-9E /71 RRUS 11 148 j m (2)DC2-48-60.0.9E 171 RRUS 11 148 DC2.48-60.0.9E 171 RRUS 11 148 10008 I RRUS 32 1171 (3)ACU-A20.N 148 i RRUS 32 171 (3)ACU-A20-N 148 V m RRUS 32 171 -(3)ACL4A20.N 148 h ¢ I Q DC6.48-60-18-BF 1171 BNMHZSMRFilter 148 a ( I I DCE48-6618-BC _ 171 800MHz SPAR FBter 140 RRUS 32 B2 171 800MW SMR Filter 148 I ? (2)RRUS 32 82 171 24•Dia[&tt Maurd Rpe 148 C RRUS 32 B66 1171 24•Diax 8-tt Moved Pipe 146 1 (2)RRUS 32 B66 171 _24•Dia x 8-n Moved Rpe 148 U RRUS4478B14 CCIV2 171 Sire Pro l VFA12-HD 148 o I BO.o tl RRUS 4a7B B14_CCM 171 Sae No 1 VFA12i1D 148- RRUS4478B14_CCIV2 171 Sde Pro l VFA12-HD 1a8 c m 1 RRU54449 BS1B12 171 H&X-AW-23-33-0OT 140 y I -m RRUS 444985/M12 1171 __ Ha-%-AW-23.33-00T 140 & ! RRUS 4449 B54312 171 HB-X-AW-2333-00T 140 DC614-60.183C 1171 Sectx Moved ISM 40231 140 1 700tt 1" I N I SYMBOL LIST p z I f I MARK SIZE I MARK I SEE ! i A I L130x1314XV16 C 2L312x31lh1/4x12 60.0tt B 2L3K1x3116t12 - ________ D 2L3 R.12x3/Bx112 -_ I I i _ MATERIAL STRENGTH GRADE I Fy Fu GRADE Fy Fu A53-B-4fi 46 ksI 67 W A3fi 36 ksI 58IrsI ' TOWER DESIGN NOTES 1.Tower is located in Pasco County,Florida o + I 2.Tower designed for Exposure C to the TIA-222-H Standard. 3 ! 400 n 3.Tower designed for a 137 mph basic wind in accordance with the TIA-222-H Standard. 4. Defections are based upon a 60 mph wind. - 5.Tower Risk Category 11. ( 6.Topographic Category 1 with Crest Height of 0.00 it 7.TOWER RATING:88.9% o tt ALL REACTIONS t- ARE FACTORED _ I d m ' MAX.CORNER REACTIONS AT BASE: Z 6 i DOWN:61844316 20 o tt SHEAR:60870/b UPLIFT.'•54657316 SHEAR:54798 Ib x I ! AXIAL 843521b iz 1 SHEAR MOMENT I 98061 Ib� 10906466 lb-ft 0.0 tt_ I I TORQUE 78542I15-ft I $ REACTIONS-137 mph WIND I = _ o u s 6 g 3 - e in a 3 Tower Engineering Professionals cb Pasco Count VS BU 826548 A326 Tryon Road Pro- TEPNa.48167.283829 Raleigh,INC 27603 aeon.Crown Castle Z:!'y mfrank API": To-Eryine HM RolesswrWs Phone:(919)661-6351 Coda TIA-222-H Dale'07/22/19 �NTS FAX: 919 661-6350 Pam. °w"9 No.E-1 thxAlOWer Job Pasco County(VS) (BU 826548) Page of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX,•(919)661-6350 Tower Input Data The main tower is a 3x free standing tower with an overall height of 190.00 ft above the ground line. The base of the tower is set at an elevation of 0.00 ft above the ground line. The face width of the tower is 8.00 ft at the top and 21.33 ft at the base. This tower is designed using the TIA-222-H standard. The following design criteria apply: Tower is located in Pasco County,Florida. Tower base elevation above sea level:91.00 ft. Basic wind speed of 137 mph. Risk Category II. Exposure Category C. Simplified Topographic Factor Procedure for wind speed-up calculations is used. Topographic Category: 1. Crest Height:0.00 ft. Deflections calculated using a wind speed of 60 mph. Pressures are calculated at each section. Tower analysis based on target reliabilities in accordance with Annex S. Load Modification Factors used:Kes(Fw)=0.95. Stress ratio used in tower member design is 1.05. Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered. Options Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments-Horizontals Assume Legs Pinned J Calculate Redundant Bracing Forces Consider Moments-Diagonals 4 Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification J Use Clear Spans For Wind Area 4 SR Leg Bolts Resist Compression Use Code Stress Ratios J Use Clear Spans For KL/r All Leg Panels Have Same Allowable Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice 4 Bypass Mast Stability Checks 4 Consider Feed Line Torque Always Use Max Kz J Use Azimuth Dish Coefficients J Include Angle Block Shear Check Use Special Wind Profile 4 Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.Exemption 4 Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC.6D+W Combination _ _ Poles 4 Secondary Horizontal Braces Leg Sort Capacity Reports By Component Include Shear-Torsion Interaction Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Ignore KLry For 60 Deg.Angle Legs Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are Known b tnxTower Jo Pasco County(VS) (BU 826548) Page2 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX.(919)661-6350 Wind 180 f- Lea A Wind 90 �4Q d0 Q Io Leg C Z Leg B Face C Wind Normal Triangular Tower Tower Section Geometry Tower Tower Assembly Description Section Number Section Section Elevation Database Width of Length Sections ft ft ft Tl 190.00-180.00 8.00 1 10.00 T2 180.00-160.00 8.00 1 20.00 T3 160.00-140.00 8.00 1 20.00 T4 140.00-120.00 9.67 1 20.00 T5 120.00-113.33 11.33 1 6.67 T6 113.33-106.67 11.89 1 6.67 T7 106.67-100.00 12.44 1 6.67 T8 100.00-80.00 13.00 1 20.00 T9 80.00-70.00 14.67 1 10.00 T10 70.00-60.00 15.50 1 10.00 Tl 1 60.00-40.00 16.33 1 20.00 T12 40.00-30.00 18.00 1 10.00 T13 30.00-20.00 18.83 1 10.00 T14 20.00-0.00 19.67 1 20.00 Tower Section Geometry cont'd Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type K Brace Horizontals Offset Offset End ft ft Panels in in Tl 190.00-180.00 5.00 X Brace No No 0.0000 0.0000 W xTower Job Pasco County(VS) (BU 826548) Page3 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phase:(919)661-6351 Crown Castle mfrank FAX:(919)661-6350 Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type K Brace Horizontals Offset Offset End ft ft Panels in in T2 I80.00-160.00 5.00 X Brace No No 0.0000 0.0000 T3 160.00-140.00 6.67 X Brace No No 0.0000 0.0000 T4 140.00-120.00 6.67 X Brace No No 0.0000 0.0000 T5 I20.00-113.33 6.67 X Brace No No 0.0000 0.0000 T6 113.33-106.67 6.67 X Brace No No 0.0000 0.0000 T7 106.67-100.00 6.67 X Brace No No 0.0000 0.0000 T8 100.00-80.00 10.00 X Brace No No 0.0000 0.0000 T9 80.00-70.00 10.00 X Brace No No 0.0000 0.0000 T10 70.00-60.00 10.00 X Brace No No 0.0000 0.0000 Tl 1 60.00-40.00 10.00 X Brace No No 0.0000 0.0000 T12 40.00-30.00 10.00 X Brace No No 0.0000 0.0000 T13 30.00-20.00 10.00 X Brace No No 0.0000 0.0000 T14 20.00-0.00 10.00 X Brace No No 0.0000 0.0000 Tower Section Geometry cont'd Tower Leg Leg Leg Diagonal Diagonal Diagonal Elevation Type Size Grade Type Size Grade ft Tl 190.00-180.00 Pipe Pipe 2.5 STD A53-B-46 Equal Angle L1 3/4xl 3/4x3/16 A36 (46 ksi) (36 ksi) T2 180.00-160.00 Pipe PIPE 3.5 STD A53-13 46 Equal Angle L2x2x3/16 A36 (46 ksi) (36 ksi) T3 160.00-140.00 Pipe Pipe 5 STD A53-13-46 Double Equal 2L2 1/2x2 1/2x3/16x3/8 A36 (46 ksi) Angle (36 ksi) T4 140.00-120.00 Pipe Pipe 8 STD A53-B-46 Equal Angle L3x3x3/16 A36 (46 ksi) (36 ksi) T5 120.00-113.33 Pipe Pipe 8 STD A53-B-46 Equal Angle L3x3x3/16 A36 (46 ksi) (36 ksi) T6 113.33-106.67 Pipe Pipe 8 STD A53-B-46 Equal Angle L3x3x3/16 A36 (46 ksi) (36 ksi) T7 106.67-100.00 Pipe Pipe 8 STD A53-B-46 Double Equal 2L3x3x3/16xl/2 A36 (46 ksi) Angle (36 ksi) T8 100.00-80.00 Pipe Pipe 10 STD(SCH40) A53-B-46 Equal Angle L3 1/2x3 1/2xl/4 A36 (46 ksi) (36 ksi) T9 80.00-70.00 Pipe Pipe 10 STD(SCH40) A53-B-46 Equal Angle L3 1/2x3 1/2xl/4 A36 (46 ksi) (36 ksi) T10 70.00-60.00 Pipe Pipe 10 STD(SCH40) A53-B-46 Double Equal 2L3 1/2x3 1/2xl/4xl/2 A36 (46 ksi) Angle (36 ksi) Tl 160.00-40.00 Pipe Pipe 12 STD A53-B-46 Equal Angle L3 1/2x3 1/20/8 A36 (46 ksi) (36 ksi) T12 40.00-30.00 Pipe Pipe 12 STD A53-B-46 Equal Angle L3 1/20 1/2x3/8 A36 (46 ksi) (36 ksi) T13 30.00-20.00 Pipe Pipe 12 STD A53-B-46 Double Equal 2L3 1/2x3 1/2x3/8xl/2 A36 (46 ksi) Angle (36 ksi) T1420.00-0.00 Pipe Pipe 12 XH A53-B-46 Equal Angle L4x4x3/8 A36 (46 ksi) (36 ksi) Tower Section Geometry cont'd Job W xTowe, Pasco County(VS) (BU 826548) Page4 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX:(919)661-6350 Tower Top Girt Top Girt Top Girt Bottom Girt Bottom Girt Bottom Girt Elevation Type Size Grade Type Sire Grade f TI 190.00-180.00 Equal Angle L3 1/2x3 1/2xl/4 A36 Solid Round A36 (36 ksi) (36 ksi) 12 180.00-160.00 Equal Angle L3 1/2x3 1/2xl/4 A36 Solid Round A36 (36 ksi) (36 ksi) T3 160.00-140.00 Equal Angle L3 1/2x3 1/2x3/8 A36 Solid Round A36 (36 ksi) (36 ksi) T4 140.00-120.00 Equal Angle L3 1/20 1/2x3/8 A36 Solid Round A36 (36 ksi) (36 ksi) T5 120.00-113.33 Equal Angle L4x4x3/8 A36 Solid Round A36 (36 ksi) (36 ksi) T8 100.00-80.00 Equal Angle L4x4x3/8 A36 Solid Round A36 (36 ksi) (36 ksi) T9 80.00-70.00 Equal Angle L5x5x5/16 A36 Solid Round A36 (36 ksi) (36 ksi) TI 1 60.00-40.00 Equal Angle L5x5x5/16 A36 Solid Round A36 (36 ksi) (36 ksi) T12 40.00-30.00 Equal Angle L5x5x5/16 A36 Solid Round A36 (36 ksi) (36 ksi) T14 20.00-0.00 Equal Angle L5x5x5/16 A36 Solid Round A36 (36 ksi) (36 ksi) Tower Section Geometry cont'd Tower Gusset Gusset Gusset Grade Adjust.Factor Adjust. Weight Mu/t. Double Angle Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Spacing Diagonals Horizontals Redundants ft ft' in in in in TI 0.00 0.3750 A36 1.03 1 1.05 0.0000 0.0000 36.0000 190.00-180.00 (36 ksi) 72 0.00 0.3750 A36 1.03 1 1.05 0.0000 0.0000 36.0000 180.00-160.00 (36 ksi) T3 0.00 0.3750 A36 1.03 1 1.05 Third-Pt 0.0000 36.0000 160.00-140.00 (36 ksi) T4 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 140.00-120.00 (36 ksi) T5 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 120.00-113.33 (36 ksi) T6 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 113.33-106.67 (36 ksi) T7 0.00 0.5000 A36 1.03 1 1.05 Third-Pt 0.0000 36.0000 106.67-100.00 (36 ksi) T8 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 100.00-80.00 (36 ksi) T9 80.00-70.00 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 (36 ksi) TIO 0.00 0.5000 A36 1.03 1 1.05 Third-Pt 0.0000 36.0000 70.00-60.00 (36 ksi) Tll 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 60.00-40.00 (36 ksi) T12 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 40.00-30.00 (36 ksi) T13 0.00 0.5000 A36 1.03 1 1.05 Third-Pt 0.0000 36.0000 30.00-20.00 (36 ksi) T14 20.00-0.00 0.00 0.5000 A36 1.03 1 1.05 0.0000 0.0000 36.0000 (36 ksi) thX�[ ®�er Job Page Pasco County(VS) (BU 826548) 5 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX.-(919)661-6350 Tower Section Geometry (cont'd K Factors' Tower Calc Calc Legs X K Single Girts Horiz. Sec. Inner Elevation K K Brace Brace Diags Horiz. Brace Single Solid Diags Diags Angles Rounds X X X X X X X ft Y Y Y Y Y Y Y T1 Yes No 1 1 I 1 1 1 1 1 190.00-180.00 1 1 1 1 1 1 I T2 Yes No 1 1 1 1 1 1 1 1 180.00-160.00 1 1 1 1 1 I 1 T3 Yes No 1 1 1 1 1 1 1 1 160.00-140.00 1 1 1 1 1 1 1 T4 Yes No I I I 1 1 1 1 1 140.00-120.00 1 1 1 1 1 1 1 T5 Yes No 1 1 1 1 1 1 1 1 120.00-113.33 1 1 1 1 1 1 1 T6 Yes No 1 I I 1 1 1 1 1 113.33-106.67 1 1 1 1 1 1 1 T7 Yes No 1 1 1 1 1 1 1 1 106.67-100.00 1 1 1 1 1 1 1 T8 Yes No 1 1 1 1 1 1 1 1 100.00-80.00 1 1 1 1 1 1 1 T9 Yes No 1 1 I 1 1 1 1 1 80.00-70.00 1 1 1 1 1 1 1 T10 Yes No 1 1 I 1 1 1 1 1 70.00-60.00 1 1 1 1 1 1 1 T11 Yes No 1 1 I 1 1 1 1 1 60.00-40.00 1 1 1 1 1 1 1 T12 Yes No 1 1 I 1 1 1 1 1 40.00-30.00 1 1 1 1 I 1 1 T13 Yes No 1 1 1 1 1 1 1 1 30.00-20.00 1 1 1 1 1 1 1 T14 Yes No 1 1 1 1 1 1 1 1 20.00-0.00 1 1 1 1 1 1 1 Note:Kfactors are applied to member segment lengths.K-braces without inner supporting members will have the K factor in the out-of-plane direction applied to the overall length. Tower Section Geometry (cont'd) Tower Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Elevation ft Net Width U Net Width U Net Width U Net U Net U Net U Net U Deduct Deduct Deduct Width Width Width Width in in in Deduct Deduct Deduct Deduct in in in in Tl 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 190.00-180.00 T2 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 180.00-160.00 T3 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 160.00-140.00 T4 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 140.00-120.00 Job Page MxTowe� Pasco County(VS) (BU 826548) 6 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC27603 Client Designed by Phase:(919)661-6351 Crown Castle FAX:(919)661-6350 mfrank Tower Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Elevation ft Net Width U Net Width U Net Width U Net U Net U Net U Net U Deduct Deduct Deduct Width Width Width Width in in in Deduct Deduct Deduct Deduct in in in in T5 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 120.00-113.33 T6 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 113.33-106.67 T7 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 106.67-100.00 T8 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 100.00-80.00 T9 80.00-70.00 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T10 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 70.00-60.00 Tll 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 60.00-40.00 T12 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 40.00-30.00 T13 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 30.00-20.00 T14 20.00-0.001 0.0000 l 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 Tower Section Geometry cont'd Tower Leg Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Elevation Connection ft Type Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. in in in in in in in T1 Flange 0.7500 4 0.5000 2 0.5000 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 190.00-180.00 A325N A325N A325N A325N A325N A325N A325N T2 Flange 0.8750 4 0.5000 2 0.5000 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 180.00-160.00 A325N A325N A325N A325N A325N A325N A325N T3 Flange 1.0000 6 0.7500 1 0.7500 1 0.0000 0 0.6250 0 0.6250 0 0.6250 0 160.00-140.00 A325N A325X A325N A325N A325N A325N A325N T4 Flange 1.5000 4 0.6250 2 0.6250 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 140.00-120.00 A325N A325N A325N A325N A325N A325N A325N T5 Flange 1.5000 0 0.6250 2 0.6250 1 0.0000 0 0.6250 0 0.6250 0 0.6250 0 120.00-113.33 A325N A325N A325N A325N A325N A325N A325N T6 Flange 1.5000 0 0.6250 2 0.6250 0 0.0000 0 0.6250 0 0.6250 0 0.6250 0 113.33-106.67 A325N A325N A325N A325N A325N A325N A325N T7 Flange 1.5000 6 0.6250 2 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 106.67-100.00 A325N A325X A325N A325N A325N A325N A325N T8 Flange 1.5000 6 0.7500 2 0.7500 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 100.00-80.00 A325N A325N A325N A325N A325N A325N A325N T9 80.00-70.00 Flange 1.5000 0 0.6250 2 0.6250 1 0.0000 0 0.6250 0 0.6250 0 0.6250 0 A325N A325N A325N A325N A325N A325N A325N T10 Flange 1.5000 6 0.6250 2 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 70.00-60.00 A325N A325X A325N A325N A325N A325N A325N Tll Flange 1.5000 6 0.7500 2 0.7500 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 60.00-40.00 A325N A325N A325N A325N A325N A325N A325N T12 Flange 1.5000 0 0.7500 2 0.7500 1 0.0000 0 0.6250 0 0.6250 0 0.6250 0 40.00-30.00 A325N A325N A325N A325N A325N A325N A325N TO Flange 1.5000 6 0.7500 2 0.6250 0 0.6250 0 0.6250 0 0.6250 0 0.6250 0 30.00-20.00 A325N A325X A325N A325N A325N A325N A325N e MxTower Job Pasco County(VS) (BU 826548) Page 7 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX.(919)661-6350 mfrank Tower Leg Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Hori_ontal Elevation Connection ft Type Bolt Size No. Bolt Sire No. Bolt Size No. Bolt Sire No. Bolt Size No. Bolt Size No. Bolt Size No. in in in in in in in T14 20.00-0.00 Flange 2.2500 0 0.7500 2 0.7500 1 0.6250 0 0.6250 0 0.6250 0 0.6250 0 A615-75 A325N A325N A325N A325N A325N A325N Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Face Allow Exclude Component Placement Face Lateral # # Clear Width or Perimeter Weight or Shield From Type Offset Offset Per Spacing Diameter Leg Torque ft in (Frac FW) Row in in in ply, Calculation **Safety** Safety Line B No No At(CaAa) 190.00- -8.0000 0.45 I 1 0.3750 0.3750 0.22 3/8 0.00 Climbing B No No Af(CaAa) 190.00- -8.0000 0.45 1 1 3.0000 3.0000 4.00 Ladder(Af) 0.00 **A Face** 942-98887-1 F A No No At(CaAa) 148.00- 0.0000 0.42 3 3 0,5000 1.3000 1.26 XXX(1-1/4) 0.00 Feed Line A No No Af(CaAa) 150.00- 0.0000 0.45 1 1 3.0000 3.0000 4.00 Ladder 0.00 MLE Hybrid A No No At(CaAa) 160.00- 2.5000 -0.3 1 1 0.5000 1.2500 0.68 3Power/6Fiber 0.00 RL 2(1-1/4) LCF158-50JL( A No No Ar(CaAa) 160.00- 0.0000 -0.25 12 12 0.5000 1.9800 0.52 1 5/8") 0.00 Feed Line A No No Af(CaAa) 160.00- 0.0000 -0.25 1 I 3.0000 3.0000 4.00 Ladder 0.00 **B Face** LDF7-50A(I- B No No Ar(CaAa) 171.00- 0.0000 -0.3 12 12 0.5000 1.9800 0.82 5/8") 0.00 LDFS-50A(7/ B No No At(CaAa) 171.00- 2.5000 -0.26 6 6 0.5000 1.0900 0.33 8") 0.00 ATCB-BOl(5/ B No No Ar(CaAa) 171.00- 3.2000 -0.34 3 3 0.3150 0.3150 0.07 16") 0.00 F13-1-9813-002- B No No Ar(CaAa) 171.00- 2.5000 -0.34 2 2 0.3937 0.0001 0.06 XXX(3/8) 0.00 WR-VG86ST- B No No At(CaAa) 171.00- 2.5000 -0.3 3 3 0.5000 0.0001 0.58 BRD(3/4) 0.00 FB-L9813-002- B No No At(CaAa) 171.00- 0.0000 -0.36 1 1 0.3937 0.3937 0.06 XXX(3/8) 0.00 WR-VG86ST- B No No Ar(CaAa) 171.00- 2.5000 -0.36 3 3 0.5000 0.7950 0.58 BRD(3/4) 0.00 Feed Line B No No Af(CaAa) 171.00- 2.5000 -0.3 1 1 3.0000 3.0000 4.00 Ladder 0.00 **C Face** LDF7-50A(1- C No No At(CaAa) 140.00- 0.0000 0.45 6 6 0.5000 1.9800 0.82 5/8") 0.00 Feed Line C No No Af(CaAa) 140.00- 0.0000 0.45 1 1 3.0000 3.0000 4.00 Ladder 0.00 *** LDF7-50A(1- C No No Ar(CaAa) 190.00- 0.0000 -0.1 12 12 0.5000 1.9800 0.82 5/8") 0.00 ASU9325TYP C No No At(CaAa) 190.00- 1.7500 -0.05 1 1 0.5000 1.5840 1.61 01(1-3/5) 0.00 HCS 2.0 Part C No No Ar(CaAa) 190.00- 1.7500 -0.06 1 1 0.5000 1.5500 1.71 Job Page x7 tn 'wer Pasco County(VS) (BU 826548) 8 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX:(919)661-6350 Description Face Allow Exclude Component Placement Face Lateral # # Clear Width or Perimeter Weight or Shield From Type Offset Offset Per Spacing Diameter Leg Torque ft in (Frac FW) Row in in in p(f Calculation 3(1-1/2) 0.00 Feed Line C No No Af(CaAa) 190.00- 0.0000 0 1 1 3.0000 3.0000 4.00 Ladder 0.00 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Exclude Component Placement Total CAAA Weight or Shield From Type Number Leg Torque ft fil/ft p!f Calculation s+ Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Section Elevation In Face Out Face ft ft= ft2 ft1 ft2 lb Tl 190.00-180.00 A 0.000 0.000 0.000 0.000 0 B 0.000 0.000 5.375 0.000 42 C 0.000 0.000 31.894 0.000 172 T2 180.00-160.00 A 0.000 0.000 0.000 0.000 0 B 0.000 0.000 53.677 0.000 302 C 0.000 0.000 63.788 0.000 343 T3 160.00-140.00 A 0.000 0.000 68.140 0.000 289 B 0.000 0.000 88.798 0.000 479 C 0.000 0.000 63.788 0.000 343 T4 140.00-120.00 A 0.000 0.000 77.820 0.000 374 B 0.000 0.000 88.798 0.000 479 C 0.000 0.000 97.548 0.000 522 T5 120.00-113.33 A 0.000 0.000 25.940 0.000 125 B 0.000 0.000 29.599 0.000 160 C 0.000 0.000 32.516 0.000 174 T6 113.33-106.67 A 0.000 0.000 25.940 0.000 125 B 0.000 0.000 29.599 0.000 160 C 0.000 0.000 32.516 0.000 174 T7 106.67-100.00 A 0.000 0.000 25.940 0.000 125 B 0.000 0.000 29.599 0.000 160 C 0.000 0.000 32.516 0.000 174 T8 100.00-80.00 A 0.000 0.000 77.820 0.000 374 B 0.000 0.000 88.798 0.000 479 C 0.000 0.000 97.548 0.000 522 T9 80.00-70.00 A 0.000 0.000 38.910 0.000 187 B 0.000 0.000 44.399 0.000 240 C 0.000 0.000 48.774 0.000 261 T10 70.00-60.00 A 0.000 0.000 38.910 0.000 187 B 0.000 0.000 44.399 0.000 240 C 0.000 0.000 48.774 0.000 261 Tll 60.00-40.00 A 0.000 0.000 77.820 0.000 374 B 0.000 0.000 88.798 0.000 479 Job Page MxTowe� Pasco County(VS) (BU 826548) 9 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed b Phone:(919)661-6351 Crown Castle g y FAX. (919)661-6350 mfrank Tower Tower Face AA AF C`4A,4 C,,A,., Weight Section Elevation In Face Out Face r ft, fr ft, fr lb C 0.000 0.000 97.548 0.000 522 T12 40.00-30.00 A 0.000 0.000 38.910 0.000 187 B 0.000 0.000 44.399 0.000 240 C 0.000 0.000 48.774 0.000 261 T13 30.00-20.00 A 0.000 0.000 38.910 0.000 187 B 0.000 0.000 44.399 0.000 240 C 0.000 0.000 48.774 0.000 261 T14 20.00-0.00 A 0.000 0.000 77.820 0.000 374 B 0.000 0.000 88.798 0.000 479 C 0.000 0.000 97.548 0.000 522 Feed Line Center of Pressure Section Elevation CPA- CPZ CPA• CPZ Ice Ice ft in in in in Tl 190.00-180.00 4.7941 6.9258 4.7925 6.9224 72 180.00-160.00 5.6054 -5.5179 5.5096 -5.4030 T3 160.00-140.00 0.3250 -9.2034 0.3128 -8.8662 T4 140.00-120.00 -5.1259 -9.2438 -4.9097 -8.8371 T5 120.00-113.33 -5.0832 -9.2836 -4.9052 -8.9408 T6 113.33-106.67 -5.9050 -10.6721 -5.6222 -10.1390 T7 106.67-100.00 -6.0969 -11.0390 -5.8022 -10.4818 T8 100.00-80.00 -6.1988 -11.2440 -5.8739 -10.6280 T9 80.00-70.00 -6.1370 -11.2533 -5.8573 -10.7120 T10 70.00-60.00 -7.2255 -13.1018 -6.7892 -12.2767 Tll 60.00-40.00 -6.9414 -12.6850 -6.5450 -11.9243 T12 40.00-30.00 -6.7968 -12.5413 -6.4564 -11.8758 T13 30.00-20.00 -8.0733 -14.7068 -7.5326 -13.6768 T14 20.00-0.00 -7.5210 -13.8947 -7.1114 -13.0929 Shielding Factor Ka Tower Feed Line Description Feed Line K. K Section Record No. Se ment Elev. No Ice Ice Tl 2 Safety Line 3/8 180.00- 0.6000 0.6000 190.00 Tl 3 Climbing Ladder(Af) 180.00- 0.6000 0.6000 190.00 T1 26 LDF7-50A(I-5/8") 180.00- 0.6000 0.6000 190.00 Tl 27 ASU9325TYP01(1-3/5) 180.00- 0.6000 0.6000 190.00 Tl 28 HCS 2.0 Part 3(1-1/2) 180.00- 0.6000 0.6000 190.00 Tl 29 Feed Line Ladder 180.00- 0.6000 0.6000 190.00 T2 2 Safety Line 3/8 160.00- 0.6000 0.6000 180.00 72 3 Climbing Ladder(Af) 160.00- 0.6000 0.6000 180.00 T2 11 LDF7-50A(1-5/8") 160.00- 0.6000 0.6000 b WxT awes Jo Pasco County(VS) (BU 826548) Page 10 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX.-(919)661-6350 mfrank Tower Feed Line Description Feed Line K. K. Section Record No. Se ment Eler. No Ice Ice 171.00 T2 12 LDF5-50A(7/8") 160.00- 0.6000 0.6000 171.00 T2 13 ATCB-BOI(5/16") 160.00- 0.6000 0.6000 171.00 T2 14 FB-L98B-002-XXX(3/8) 160.00- 0.6000 0.6000 171.00 T2 15 WR-VG86ST-BRD(3/4) 160.00- 0.6000 0.6000 171.00 T2 16 FB-L98B-002-XXX(3/8) 160.00- 0.6000 0.6000 171.00 T2 17 WR-VG86ST-BRD(3/4) 160.00- 0.6000 0.6000 171.00 T2 18 Feed Line Ladder 160.00- 0.6000 0.6000 171.00 T2 26 LDF7-50A(1-5/8") 160.00- 0.6000 0.6000 180.00 T2 27 ASU9325TYP01(1-3/5) 160.00- 0.6000 0.6000 180.00 T2 28 HCS 2.0 Part 3(1-1/2) 160.00- 0.6000 0.6000 180.00 72 29 Feed Line Ladder 160.00- 0.6000 0.6000 180.00 T3 2 Safety Line 3/8 140.00- 0.6000 0.6000 160.00 T3 3 Climbing Ladder(Af) 140.00- 0.6000 0.6000 160.00 T3 5 942-98887-1FXXX(1-1/4) 140.00- 0.6000 0.6000 148.00 T3 6 Feed Line Ladder 140.00- 0.6000 0.6000 150.00 T3 7 MLE Hybrid 3Power/6Fiber 140.00- 0.6000 0.6000 RL2(1-1/4) 160.00 T3 8 LCF158-50JL( 1 5/8") 140.00- 0.6000 0.6000 160.00 T3 9 Feed Line Ladder 140.00- 0.6000 0.6000 160.00 T3 I 1 LDF7-50A(1-5/8") 140.00- 0.6000 0.6000 160.00 T3 12 LDF5-50A(7/8") 140.00- 0.6000 0.6000 160.00 T3 13 ATCB-1301(5/16") 140.00- 0.6000 0.6000 160.00 T3 14 FB-L98B-002-XXX(3/8) 140.00- 0.6000 0.6000 160.00 T3 15 WR-VG86ST-BRD(3/4) 140.00- 0.6000 0.6000 160.00 T3 16 FB-L98B-002-XXX(3/8) 140.00- 0.6000 0.6000 160.00 T3 17 WR-VG86ST-BRD(3/4) 140.00- 0.6000 0.6000 160.00 T3 18 Feed Line Ladder 140.00- 0.6000 0.6000 160.00 T3 26 LDF7-SOA(1-5/8") 140.00- 0.6000 0.6000 160.00 T3 27 ASU9325TYP01(1-3/5) 140.00- 0.6000 0.6000 160.00 T3 28 HCS 2.0 Part 3(1-1/2) 140.00- 0.6000 0.6000 160.00 T3 29 Feed Line Ladder 140.00- 0.6000 0.6000 160.00 T4 2 Safety Line 3/8 120.00- 0.6000 0.6000 Job Page WxTower Pasco County(VS) (BU 826548) 11 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX--(919)661-6350 mfrank Tower Feed Line Description Feed Line K. K" Section Record No. Se ment Elev. No Ice Ice 140.00 T4 3 Climbing Ladder(Af) 120.00- 0.6000 0.6000 140.00 T4 5 942-98887-1FXXX(1-1/4) 120.00- 0.6000 0.6000 140.00 T4 6 Feed Line Ladder 120.00- 0.6000 0.6000 140.00 T4 7 MLE Hybrid 3Power/6Fiber 120.00- 0.6000 0.6000 RL 2(1-1/4) 140.00 T4 8 LCF158-50JL(1 5/8") 120.00- 0.6000 0.6000 140.00 T4 9 Feed Line Ladder 120.00- 0.6000 0.6000 140.00 T4 11 LDF7-50A(1-5/8") 120.00- 0.6000 0.6000 140.00 T4 12 LDF5-50A(7/8") 120.00- 0.6000 0.6000 140.00 T4 13 ATCB-B01(5/16") 120.00- 0.6000 0.6000 140.00 T4 14 FB-L98B-002-XXX(3/8) 120.00- 0.6000 0.6000 140.00 T4 15 WR-VG86ST-BRD(3/4) 120.00- 0.6000 0.6000 140.00 T4 16 FB-L98B-002-XXX(3/8) 120.00- 0.6000 0.6000 140.00 T4 17 WR-VG86ST-BRD(3/4) 120.00- 0.6000 0.6000 140.00 T4 18 Feed Line Ladder 120.00- 0.6000 0.6000 140.00 T4 20 LDF7-SOA(1-5/8") 120.00- 0.6000 0.6000 140.00 T4 21 Feed Line Ladder 120.00- 0.6000 0.6000 140.00 T4 26 LDF7-50A(1-5/8") 120.00- 0.6000 0.6000 140.00 T4 27 ASU9325TYP01(1-3/5) 120.00- 0.6000 0.6000 140.00 T4 28 HCS 2.0 Part 3(1-I/2) 120.00- 0.6000 0.6000 140.00 T4 29 Feed Line Ladder 120.00- 0.6000 0.6000 140A0 T5 2 Safety Line 3/8 113.33- 0.6000 0.6000 120.00 T5 3 Climbing Ladder(Af) 113.33- 0.6000 0.6000 120.00 T5 5 942-98887-1FXXX(1-1/4) 11333- 0.6000 0.6000 120.00 T5 6 Feed Line Ladder 113.33- 0.6000 0.6000 120.00 T5 7 MLE Hybrid 3Power/6Fiber 113.33- 0.6000 0.6000 RL2(1-1/4) 120.00 T5 8 LCF158-50JL(1 5/8") 113.33- 0.6000 0.6000 120.00 T5 9 Feed Line Ladder 113.33- 0.6000 0.6000 120.00 T5 I I LDF7-50A(1-5/8") 113.33- 0.6000 0.6000 120.00 T5 12 LDF5-50A(7/8") 113.33- 0.6000 0.6000 120.00 T5 13 ATCB-BO1(5/16") 113.33- 0.6000 0.6000 120.00 T5 14 FB-L98B-002-XXX(3/8) 113.33- 0.6000 0.6000 e WxTower Job Pasco County(VS) (BU 826548) Page 12 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phase:(919)661-6351 Crown Castle FAX.-(919)661-6350 mfrank Tower Feed Line Description Feed Line K. K. Section Record No. Segment Elev. No Ice Ice 120.00 T5 15 WR-VG86ST-BRD(3/4) 113.33- 0.6000 0.6000 120.00 T5 16 FB-L98B-002-XXX(3/8) 113.33- 0.6000 0.6000 120.00 T5 17 WR-VG86ST-BRD(3/4) 113.33- 0.6000 0.6000 120.00 T5 18 Feed Line Ladder 113.33- 0.6000 0.6000 120.00 T5 20 LDF7-50A(1-5/8") 113.33- 0.6000 0.6000 120.00 T5 21 Feed Line Ladder 113.33- 0.6000 0.6000 120.00 T5 26 LDF7-50A(1-5/8") 113.33- 0.6000 0.6000 120.00 T5 27 ASU9325TYP01(1-3/5) 113.33- 0.6000 0.6000 120.00 T5 28 HCS 2.0 Part 3(1-1/2) 113.33- 0.6000 0.6000 120.00 T5 29 Feed Line Ladder 113.33- 0.6000 0.6000 120.00 T6 2 Safety Line 3/8 106.67- 0.6000 0.6000 113.33 T6 3 Climbing Ladder(Af) 106.67- 0.6000 0.6000 113.33 T6 5 942-98887-1FXXX(1-1/4) 106.67- 0.6000 0.6000 113.33 T6 6 Feed Line Ladder 106.67- 0.6000 0.6000 113.33 T6 7 MLE Hybrid 3Power/6Fiber 106.67- 0.6000 0.6000 RL 2(1-1/4) 113.33 T6 8 LCF158-50JL( 1 5/8") 106.67- 0.6000 0.6000 113.33 T6 9 Feed Line Ladder 106.67- 0.6000 0.6000 113.33 T6 11 LDF7-50A(I-5/8") 106.67- 0.6000 0.6000 113.33 T6 12 LDF5-50A(7/8") 106.67- 0.6000 0.6000 113.33 T6 13 ATCB-BOl(5/16") 106.67- 0.6000 0.6000 113.33 T6 14 FB-L98B-002-XXX(3/8) 106.67- 0.6000 0.6000 113.33 T6 15 WR-VG86ST-BRD(3/4) 106.67- 0.6000 0.6000 113.33 T6 16 FB-L98B-002-XXX(3/8) 106.67- 0.6000 0.6000 113.33 T6 17 WR-VG86ST-BRD(3/4) 106.67- 0.6000 0.6000 113.33 T6 18 Feed Line Ladder 106.67- 0.6000 0.6000 113.33 T6 20 LDF7-50A(1-5/8") 106.67- 0.6000 0.6000 113.33 T6 21 Feed Line Ladder 106.67- 0.6000 0.6000 113.33 T6 26 LDF7-50A(1-5/8") 106.67- 0.6000 0.6000 113.33 T6 27 ASU9325TYP01(l-3/5) 106.67- 0.6000 0.6000 113.33 T6 28 HCS 2.0 Part 3(1-1/2) 106.67- 0.6000 0.6000 113.33 T6 29 Feed Line Ladder 106.67- 0.6000 0.6000 InxTower Job Pasco County(VS) (BU 826548) Page13 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client ---[Designed by Phone:(919)661-6351 Crown Castle FAX.-(919)661-6350 mfrank Tower Feed Line Description Feed Line K K. Section Record No. Segment Elev. No Ice Ice 113.33 T7 2 Safety Line 3/8 100.00- 0.6000 0.6000 106.67 T7 3 Climbing Ladder(Af) 100.00- 0.6000 0.6000 106.67 T7 5 942-98887-1FXXX(I-1/4) 100.00- 0.6000 0.6000 106.67 T7 6 Feed Line Ladder 100.00- 0.6000 0.6000 106.67 T7 7 MLE Hybrid 3Power/6Fiber 100.00- 0.6000 0.6000 RL2(1-1/4) 106.67 T7 8 LCF158-50JL(1 5/8") 100.00- 0.6000 0.6000 106.67 T7 9 Feed Line Ladder 100.00- 0.6000 0.6000 106.67 T7 1 I LDF7-50A(I-5/8") 100.00- 0.6000 0.6000 106.67 T7 12 LDF5-50A(7/8") 100.00- 0.6000 0.6000 106.67 T7 13 ATCB-BOI(5/16") 100.00- 0.6000 0.6000 106.67 T7 14 FB-L98B-002-XXX(3/8) 100.00- 0.6000 0.6000 106.67 T7 15 WR-VG86ST-BRD(3/4) 100.00- 0.6000 0.6000 106.67 T7 16 FB-L98B-002-XXX(3/8) 100.00- 0.6000 0.6000 106.67 T7 17 WR-VG86ST-BRD(3/4) 100.00- 0.6000 0.6000 106.67 T7 18 Feed Line Ladder 100.00- 0.6000 0.6000 106.67 T7 20 LDF7-50A(I-5/8") 100.00- 0.6000 0.6000 106.67 T7 21 Feed Line Ladder 100.00- 0.6000 0.6000 106.67 T7 26 LDF7-50A(I-5/8") 100.00- 0.6000 0.6000 106.67 T7 27 ASU9325TYP01(1-3/5) 100.00- 0.6000 0.6000 106.67 T7 28 HCS 2.0 Part 3(1-1/2) 100.00- 0.6000 0.6000 106.67 T7 29 Feed Line Ladder 100.00- 0.6000 0.6000 106.67 T8 2 Safety Line 3/8 80.00-100.00 0.6000 0.6000 T8 3 Climbing Ladder(AO 80.00-100.00 0.6000 0.6000 T8 5 942-98887-1FXXX(I-1/4) 80.00-100.00 0.6000 0.6000 T8 6 Feed Line Ladder 80.00-100.00 0.6000 0.6000 T8 7 MLE Hybrid 3Power/6Fiber 80.00-100.00 0.6000 0.6000 RL 2(I-1/4) T8 8 LCF158-50JL(1 5/8") 80.00-100.00 0.6000 0.6000 T8 9 Feed Line Ladder 80.00-100.00 0.6000 0.6000 T8 1 l LDF7-50A(1-5/8") 80.00-100.00 0.6000 0.6000 T8 12 LDF5-50A(7/8") 80.00-100.00 0.6000 0.6000 T8 13 ATCB-BO1(5/16") 80.00-100.00 0.6000 0.6000 T8 14 FB-L98B-002-XXX(3/8) 80.00-100.00 0.6000 0.6000 T8 15 WR-VG86ST-BRD(3/4) 80.00-100.00 0.6000 0.6000 T8 16 FB-L98B-002-XXX(3/8) 80.00-100.00 0.6000 0.6000 T8 17 WR-VG86ST-BRD(3/4) 80.00-100.00 0.6000 0.6000 T8 18 Feed Line Ladder 80.00-100.00 0.6000 0.6000 T8 20 LDF7-50A(1-5/8") 80.00-100.00 0.6000 0.6000 T8 21 Feed Line Ladder 80.00-100.00 0.6000 0.6000 T8 26 LDF7-50A(1-5/8") 80.00-100.00 0.6000 0.6000 b InxTower Jo Pasco County(VS) (BU 826548) Page14 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed b Phone:(919)661-6351 Crown Castle g y FAX.-(919)661-6350 mfrank Tower Feed Line Description Feed Line & K. Section Record No. Se ment Elev. No Ice Ice T8 27 ASU9325TYP01(1-3/5) 80.00-100.00 0.6000 0.6000 T8 28 HCS 2.0 Part 3(1-1/2) 80.00-100.00 0.6000 0.6000 T8 29 Feed Line Ladder 80.00-100.00 0.6000 0.6000 T9 2 Safety Line 3/8 70.00-80.00 0.6000 0.6000 T9 3 Climbing Ladder(Af) 70.00-80.00 0.6000 0.6000 T9 5 942-98887-1FXXX(1-1/4) 70.00-80.00 0.6000 0.6000 T9 6 Feed Line Ladder 70.00-80.00 0.6000 0.6000 T9 7 MLE Hybrid 3Power/6Fiber 70.00-80.00 0.6000 0.6000 RL 2(1-1/4) T9 8 LCF158-50JL(1 5/8") 70.00-80.00 0.6000 0.6000 T9 9 Feed Line Ladder 70.00-80.00 0.6000 0.6000 T9 1 I LDF7-50A(1-5/8") 70.00-80.00 0.6000 0.6000 T9 12 LDF5-50A(7/8") 70.00-80.00 0.6000 0.6000 T9 13 ATCB-BO1(5/16") 70.00-80.00 0.6000 0.6000 T9 14 FB-L98B-002-XXX(3/8) 70.00-80.00 0.6000 0.6000 T9 15 WR-VG86ST-BRD(3/4) 70.00-80.00 0.6000 0.6000 T9 16 FB-L98B-002-XXX(3/8) 70.00-80.00 0.6000 0.6000 T9 17 WR-VG86ST-BRD(3/4) 70.00-80.00 0.6000 0.6000 T9 18 Feed Line Ladder 70.00-80.00 0.6000 0.6000 T9 20 LDF7-50A(1-5/8") 70.00-80.00 0.6000 0.6000 T9 21 Feed Line Ladder 70.00-80.00 0.6000 0.6000 T9 26 LDF7-50A(I-5/8") 70.00-80.00 0.6000 0.6000 T9 27 ASU9325TYPOI(1-3/5) 70.00-80.00 0.6000 0.6000 T9 28 HCS 2.0 Part 3(1-1/2) 70.00-80.00 0.6000 0.6000 T9 29 Feed Line Ladder 70.00-80.00 0.6000 0.6000 T10 2 Safety Line 3/8 60.00-70.00 0.6000 0.6000 TI O 3 Climbing Ladder(AO 60.00-70.00 0.6000 0.6000 T10 5 942-98887-1FXXX(1-1/4) 60.00-70.00 0.6000 0.6000 T10 6 Feed Line Ladder 60.00-70.00 0.6000 0.6000 T10 7 MLE Hybrid 3Power/6Fiber 60.00-70.00 0.6000 0.6000 RL 2(1-1/4) TIO 8 LCF158-50JL(1 5/8") 60.00-70.00 0.6000 0.6000 T10 9 Feed Line Ladder 60.00-70.00 0.6000 0.6000 T10 11 LDF7-50A(1-5/8") 60.00-70.00 0.6000 0.6000 T10 12 LDF5-50A(7/8") 60.00-70.00 0.6000 0.6000 T10 13 ATCB-BO1(5/16") 60.00-70.00 0.6000 0.6000 T10 14 FB-L98B-002-XXX(3/8) 60.00-70.00 0.6000 0.6000 T10 15 WR-VG86ST-BRD(3/4) 60.00-70.00 0.6000 0.6000 T10 16 FB-L98B-002-XXX(3/8) 60.00-70.00 0.6000 0.6000 T10 17 WR-VG86ST-BRD(3/4) 60.00-70.00 0.6000 0.6000 T10 18 Feed Line Ladder 60.00-70.00 0.6000 0.6000 T10 20 LDF7-50A(1-5/8") 60.00-70.00 0.6000 0.6000 T10 21 Feed Line Ladder 60.00-70.00 0.6000 0.6000 T10 26 LDF7-50A(1-5/8") 60.00-70.00 0.6000 0.6000 T10 27 ASU9325TYP01(I-3/5) 60.00-70.00 0.6000 0.6000 T10 28 HCS 2.0 Part 3(1-1/2) 60.00-70.00 0.6000 0.6000 T10 29 Feed Line Ladder 60.00-70.00 0.6000 0.6000 Tl I 2 Safety Line 3/8 40.00-60.00 0.6000 0.6000 Tl I 3 Climbing Ladder(At) 40.00-60.00 0.6000 0.6000 Tll 5 942-98887-1FXXX(1-1/4) 40.00-60.00 0.6000 0.6000 Tl 1 6 Feed Line Ladder 40.00-60.00 0.6000 0.6000 TI I 7 MLE Hybrid 3Power/6Fiber 40.00-60.00 0.6000 0.6000 RL 2(1-1/4) Tl 1 8 LCF158-50JL(1 5/8") 40.00-60.00 0.6000 0.6000 Tl 1 9 Feed Line Ladder 40.00-60.00 0.6000 0.6000 TI I 11 LDF7-50A(1-5/8") 40.00-60.00 0.6000 0.6000 T11 12 LDF5-50A(7/8") 40.00-60.00 0.6000 0.6000 Tl 1 13 ATCB-BOI(5/16") 40.00-60.00 0.6000 0.6000 Tl 1 14 FB-L98B-002-XXX(3/8) 40.00-60.00 0.6000 0.6000 Tl 1 15 WR-VG86ST-BRD(3/4) 40.00-60.00 0.6000 0.6000 Tl 1 16 FB-L98B-002-XXX(3/8) 40.00-60.00 0.6000 0.6000 Tl 1 17 WR-VG86ST-BRD(3/4) 40.00-60.00 0.6000 0.6000 WxIl Owes Job Page Pasco County(VS) (BU 826548) 15 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX:(919)661-6350 mfrank Tower Feed Line Description Feed Line Ka K. Section Record No. Se ment Eler. No Ice Ice Tl l 18 Feed Line Ladder 40.00-60.00 0.6000 0.6000 Tl l 20 LDF7-50A(1-5/8") 40.00-60.00 0.6000 0.6000 Tl l 21 Feed Line Ladder 40.00-60.00 0.6000 0.6000 Tl 1 26 LDF7-50A(I-5/8") 40.00-60.00 0.6000 0.6000 Tll 27 ASU9325TYP01(I-3/5) 40.00-60.00 0.6000 0.6000 TI l 28 HCS 2.0 Part 3(1-1/2) 40.00-60.00 0.6000 0.6000 Tl 1 29 Feed Line Ladder 40.00-60.00 0.6000 0.6000 T12 2 Safety Line 3/8 30.00-40.00 0.6000 0.6000 T12 3 Climbing Ladder(Af) 30.00-40.00 0.6000 0.6000 T12 5 942-98887-1FXXX(1-1/4) 30.00-40.00 0.6000 0.6000 T12 6 Feed Line Ladder 30.00-40.00 0.6000 0.6000 T12 7 MLE Hybrid 3Power/6Fiber 30.00-40.00 0.6000 0.6000 RL 2(1-1/4) T12 8 LCF158-50JL(1 5/8") 30.00-40.00 0.6000 0.6000 T12 9 Feed Line Ladder 30.00-40.00 0.6000 0.6000 T12 11 LDF7-50A(1-5/8") 30.00-40.00 0.6000 0.6000 T12 12 LDFS-SOA(7/8") 30.00-40.00 0.6000 0.6000 T12 13 ATCB-BO1(5/16") 30.00-40.00 0.6000 0.6000 T12 14 FB-L98B-002-XXX(3/8) 30.00-40.00 0.6000 0.6000 T12 15 WR-VG86ST-BRD(3/4) 30.00-40.00 0.6000 0.6000 T12 16 FB-L98B-002-XXX(3/8) 30.00-40.00 0.6000 0.6000 T12 17 WR-VG86ST-BRD(3/4) 30.00-40.00 0.6000 0.6000 T12 18 Feed Line Ladder 30.00-40.00 0.6000 0.6000 T12 20 LDF7-50A(1-5/8") 30.00-40.00 0.6000 0.6000 T12 21 Feed Line Ladder 30.00-40.00 0.6000 0.6000 T12 26 LDF7-50A(1-5/8") 30.00-40.00 0.6000 0.6000 T12 27 ASU9325TYP01(1-3/5) 30.00-40.00 0.6000 0.6000 T12 28 HCS 2.0 Part 3(1-1/2) 30.00-40.00 0.6000 0.6000 T12 29 Feed Line Ladder 30.00-40.00 0.6000 0.6000 T13 2 Safety Line 3/8 20.00-30.00 0.6000 0.6000 T13 3 Climbing Ladder(AO 20.00-30.00 0.6000 0.6000 T13 5 942-98887-1FXXX(1-1/4) 20.00-30.00 0.6000 0.6000 T13 6 Feed Line Ladder 20.00-30.00 0.6000 0.6000 T13 7 MLE Hybrid 3Power/6Fiber 20.00-30.00 0.6000 0.6000 RL 2(1-1/4) T13 8 LCF158-50JL(1 5/8") 20.00-30.00 0.6000 0.6000 T13 9 Feed Line Ladder 20.00-30.00 0.6000 0.6000 T13 l 1 LDF7-50A(1-5/8") 20.00-30.00 0.6000 0.6000 T13 12 LDF5-50A(7/8") 20.00-30.00 0.6000 0.6000 T13 13 ATCB-BO1(5/16") 20.00-30.00 0.6000 0.6000 T13 14 FB-L98B-002-XXX(3/8) 20.00-30.00 0.6000 0.6000 T13 15 WR-VG86ST-BRD(3/4) 20.00-30.00 0.6000 0.6000 T13 16 FB-L98B-002-XXX(3/8) 20.00-30.00 0.6000 0.6000 T13 17 WR-VG86ST-BRD(3/4) 20.00-30.00 0.6000 0.6000 T13 18 Feed Line Ladder 20.00-30.00 0.6000 0.6000 T13 20 LDF7-50A(1-5/8") 20.00-30.00 0.6000 0.6000 T13 21 Feed Line Ladder 20.00-30.00 0.6000 0.6000 T13 26 LDF7-50A(1-5/8") 20.00-30.00 0.6000 0.6000 T13 27 ASU9325TYP01(I-3/5) 20.00-30.00 0.6000 0.6000 T13 28 HCS 2.0 Part 3(1-1/2) 20.00-30.00 0.6000 0.6000 T13 29 Feed Line Ladder 20.00-30.00 0.6000 0.6000 T14 2 Safety Line 3/8 0.00-20.00 0.6000 0.6000 T14 3 Climbing Ladder(AO 0.00-20.00 0.6000 0.6000 T14 5 942-98887-1FXXX(1-1/4) 0.00-20.00 0.6000 0.6000 T14 6 Feed Line Ladder 0.00-20.00 0.6000 0.6000 T14 7 MLE Hybrid 3Power/6Fiber 0.00-20.00 0.6000 0.6000 RL 2(1-1/4) T14 8 LCF158-50JL( 1 5/8") 0.00-20.00 0.6000 0.6000 T14 9 Feed Line Ladder 0.00-20.00 0.6000 0.6000 T14 11 LDF7-50A(1-5/8") 0.00-20.00 0.6000 0.6000 T14 12 LDF5-50A(7/8") 0.00-20.00 0.6000 0.6000 T14 13 ATCB-BO1(5/16") 0.00-20.00 0.6000 0.6000 e tnxTower Job Pasco County(VS) (BU 826548) Page 16 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FA 919)661-6350 mfrank X. Tower Feed Line Description Feed Line K. & Section Record No. Se ment Elev. No Ice Ice T14 14 FB-L98B-002-XXX(3/8) 0.00-20.00 0.6000 0.6000 T14 15 WR-VG86ST-BRD(3/4) 0.00-20.00 0.6000 0.6000 T14 16 FB-L98B-002-XXX(3/8) 0.00-20.00 0.6000 0.6000 T14 17 WR-VG86ST-BRD(3/4) 0.00-20.00 0.6000 0.6000 T14 18 Feed Line Ladder 0.00-20.00 0.6000 0.6000 T14 20 LDF7-50A(1-5/8") 0.00-20.00 0.6000 0.6000 T14 21 Feed Line Ladder 0.00-20.00 0.6000 0.6000 T14 26 LDF7-50A(1-5/8") 0.00-20.00 0.6000 0.6000 T14 27 ASU9325TYP01(1-3/5) 0.00-20.00 0.6000 0.6000 T14 28 HCS 2.0 Part 3(1-1/2) 0.00-20.00 0.6000 0.6000 T14 29 Feed Line Ladder 0.00-20.00 0.6000 0.6000 Discrete Tower Loads Description Face Offset Offsets: A_imuth Placement CiA.4 C,A,4 Weight or Type Harz Adjustment Front Side Leg Lateral Vert ft o ft ft-' fr' 1h ft ft s•190** CMA-BDHH/6521/EO-6 w/ A From 4.00 0.0000 190.00 No Ice 11.78 6.23 97 Mount Pipe Centroid-Fa -7.00 ce 4.00 CMA-BDHH/6521/EO-6 w/ B From 4.00 -30.0000 190.00 No Ice 11.78 6.23 97 Mount Pipe Centroid-Fa -7.00 ce 4.00 CMA-BDHH/6521/EO-6 w/ B From 4.00 60.0000 190.00 No Ice 11.78 6.23 97 Mount Pipe Centroid-Fa 7.00 ce 4.00 CMA-BDHH/6521/EO-6 w/ C From 4.00 30.0000 190.00 No Ice 11.78 6.23 97 Mount Pipe Centroid-Fa 2.00 ce 4.00 FFHH-65C-R3 w/Mount A From 4.00 0.0000 190.00 No Ice 12.97 6.20 161 Pipe Centroid-Fa 0.00 ce 4.00 FFHH-65C-R3 w/Mount B From 4.00 -30.0000 190.00 No Ice 12.97 6.20 161 Pipe Centroid-Fa -2.00 ce 4.00 FFHH-65C-R3 w/Mount C From 4.00 -60.0000 190.00 No Ice 12.97 6.20 161 Pipe Centroid-Fa -7.00 ce 4.00 FFHH-65C-R3 w/Mount C From 4.00 30.0000 190.00 No Ice 12.97 6.20 161 Pipe Centroid-Fa 7.00 ce 4.00 AEHC w/Mount Pipe A From 4.00 0.0000 190.00 No Ice 7.61 4.31 134 Centroid-Fa 7.00 ce 4.00 AEHC ti/Mount Pipe B From 4.00 -30.0000 190.00 No Ice 7.61 4.31 134 Centroid-Fa 2.00 ce 4.00 AEHC w/Mount Pipe C From 4.00 -60.0000 190.00 No Ice 7.61 4.31 134 Centroid-Fa -2.00 ce 4.00 b t�2. Tower Jo Pasco County(VS) (BU 826548) Page17 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tiyon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX.-(919)661-6350 mfrank Description Face Offset Offsets: Azimuth Placement CaA,i C4A.q Weight or Type Hors Adjustment Front Side Leg Lateral Vert ft o ft fr' ft-' lb ft ft (3)AHLOA A From 4.00 0.0000 190.00 No Ice 2.23 1.39 84 Centroid-Fa 0.00 ce 4.00 AHLOA B From 4.00 -30.0000 190.00 No Ice 2.23 1.39 84 Centroid-Fa -7.00 ce 4.00 (2)AHFIB A From 4.00 0.0000 190.00 No Ice 3.68 2.31 88 Centroid-Fa -3.50 ce 4.00 (2)AHFIB B From 4.00 -30.0000 190.00 No Ice 3.68 2.31 88 Centroid-Fa 0.00 ce 4.00 AHFIB B From 4.00 60.0000 190.00 No Ice 3.68 2.31 88 Centroid-Fa 7.00 ce 4.00 AHFIB C From 4.00 -60.0000 190.00 No Ice 3.68 2.31 88 Centroid-Fa -7.00 ce 4.00 (2)AHFIB C From 4.00 30.0000 190.00 No Ice 3.68 2.31 88 Centroid-Fa 4.50 ce 4.00 HCS 2.0 Part 1 C From 4.00 -60.0000 190.00 No Ice 1.87 0.93 24 Centroid-Fa -2.00 ce 4.00 RNSNDC-7771-PF-48 B From 4.00 -30.0000 190.00 No Ice 3.20 1.03 19 Centroid-Fa -7.00 ce 4.00 (4)2.4"x 4-ft pipe A From 4.00 0.0000 190.00 No Ice 0.00 0.87 15 Centroid-Fa 0.00 ce 2.00 (4)2.4"x 4-ft pipe B From 4.00 0.0000 190.00 No Ice 0.00 0.87 I5 Centroid-Fa 0.00 ce 2.00 (4)2.4"x 4-ft pipe C From 4.00 0.0000 190.00 No Ice 0.00 0.87 15 Centroid-Fa 0.00 ce 2.00 2.4"Dia x 6-ft Pipe A From 4.00 0.0000 190.00 No Ice 1.43 1.43 22 Centroid-Fa -2.00 ce 3.00 8'Ladder B From 2.00 0.0000 190.00 No Ice 1.53 5.33 97 Centroid-Fa 0.00 ce -4.00 Platform Mount[LP 102-1] C None 0.0000 190.00 No Ice 59.70 59.70 3780 **171** DBXNH-6565B-R2M w/ A From Leg 4.00 -60.0000 171.00 No Ice 4.09 3.30 72 Mount Pipe -6.00 4.00 DBXNH-6565B-R2M w/ B From Leg 4.00 -60.0000 171.00 No Ice 4.09 3.30 72 Mount Pipe -6.00 4.00 DBXNH-6565B-R2M w/ C From Leg 4.00 -60.0000 171.00 No Ice 4.09 3.30 72 Mount Pipe -6.00 4.00 SBJAH4-ID65B-DL w/ A From Leg 4.00 -60.0000 171.00 No Ice 5.51 4.38 91 Mount Pipe -2.00 4.00 SBJAH4-ID65B-DL w/ B From Leg 4.00 -60.0000 171.00 No Ice 5.51 4.38 91 Job Page WxTowe� Pasco County(VS) (BU 826548) 18 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX.-(919)66/-6350 mfrank Description Face Offset Offsets: Asimuth Placement CAA,, CaA,q Weight or Type Hors Adjustment Front Side Leg Lateral Inert ft o ft fr' ft-' 1b ft ft Mount Pipe -2.00 4.00 SBJAH4-1 D65B-DL w/ C From Leg 4.00 -60.0000 171.00 No Ice 5.51 4.38 91 Mount Pipe -2.00 4.00 (2)NNHH-65B-R4_CCIV2 A From Leg 4.00 -60.0000 171.00 No Ice 7.55 4.23 110 w/Mount Pipe -4.00 4.00 (2)NNHH-65B-R4_CCIV2 B From Leg 4.00 -60.0000 171.00 No Ice 7.55 4.23 110 w/Mount Pipe -4.00 4.00 (2)NNHH-65B-R4_CCIV2 C From Leg 4.00 -60.0000 171.00 No Ice 7.55 4.23 110 w/Mount Pipe -4.00 4.00 E15S09P78 B From Leg 4.00 -60.0000 171.00 No Ice 0.75 0.34 17 6.00 4.00 (2)E15S09P78 C From Leg 4.00 -60.0000 171.00 No Ice 0.75 0.34 17 0.00 4.00 DC2-48-60-0-9E A From Leg 4.00 -60.0000 171.00 No Ice 0.99 0.60 16 -6.00 4.00 (2)DC2-48-60-0-9E B From Leg 4.00 -60.0000 171.00 No Ice 0.99 0.60 16 -6.00 4.00 DC2-48-60-0-9E C From Leg 4.00 -60.0000 171.00 No Ice 0.99 0.60 16 -2.00 4.00 RRUS 32 A From Leg 4.00 -60.0000 171.00 No Ice 2.86 1.78 55 -2.00 4.00 RRUS 32 B From Leg 4.00 -60.0000 171.00 No Ice 2.86 1.78 55 -2.00 4.00 RRUS 32 C From Leg 4.00 -60.0000 171.00 No Ice 2.86 1.78 55 -2.00 4.00 DC6-48-60-18-8F A From Leg 4.00 -60.0000 171.00 No Ice 1.21 1.21 33 -2.00 4.00 DC6-48-60-18-8C B From Leg 4.00 -60.0000 171.00 No Ice 1.14 1.14 26 -6.00 4.00 RRUS 32 B2 A From Leg 4.00 -60.0000 171.00 No Ice 2.73 1.67 53 -2.00 4.00 (2)RRUS 32 B2 B From Leg 4.00 -60.0000 171.00 No Ice 2.73 1.67 53 0.00 4.00 RRUS 32 B66 A From Leg 4.00 -60.0000 171.00 No Ice 2.74 1.67 53 -2.00 4.00 (2)RRUS 32 B66 B From Leg 4.00 -60.0000 171.00 No Ice 2.74 1.67 53 0.00 4.00 RRUS 4478 B14_CCIV2 A From Leg 4.00 -60.0000 171.00 No Ice 2.02 1.25 59 b WxT owes Jo Pasco County(VS) (BU 826548) Page 19 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX.•(919)661-6350 mfrank Description Face Offset Offsets: A=imuth Placement CAA., CAA, Weight or Type Hor= Adjustment Front Side Leg Lateral Vert ft o ft ft-' ft-' lb ft ft -6.00 4.00 RRUS 4478 B 14_CCIV2 B From Leg 4.00 -60.0000 171.00 No Ice 2.02 1.25 59 -6.00 4.00 RRUS 4478 B14_CCIV2 C From Leg 4.00 -60.0000 171.00 No Ice 2.02 1.25 59 -6.00 4.00 RRUS 4449 135/13 12 A From Leg 4.00 -60.0000 171.00 No Ice 1.97 1.41 71 -2.00 4.00 RRUS 4449 135/13 12 B From Leg 4.00 -60.0000 171.00 No Ice 1.97 1.41 71 -2.00 4.00 RRUS 4449 135/1312 C From Leg 4.00 -60.0000 171.00 No Ice 1.97 1.41 71 -2.00 4.00 DC6-48-60-18-8C A From Leg 4.00 -60.0000 171.00 No Ice 1.14 1.14 26 -2.00 4.00 DC2-48-60-0-9E A From Leg 4.00 -60.0000 171.00 No Ice 0.99 0.60 16 -2.00 4.00 DC2-48-60-0-9E B From Leg 4.00 -60.0000 171.00 No Ice 0.99 0.60 16 -6.00 4.00 (2)2.9"Dia.x 8'Pipe A From Leg 4.00 0.0000 171.00 No Ice 2.30 2.30 46 4.00 0.00 (2)2.9"Dia.x 8'Pipe B From Leg 4.00 0.0000 171.00 No Ice 2.30 2.30 46 4.00 0.00 (2)2.9"Dia.x 8'Pipe C From Leg 4.00 0.0000 171.00 No Ice 2.30 2.30 46 4.00 0.00 2.4"Dia x 12-ft Pipe A From Leg 4.00 0.0000 171.00 No Ice 2.86 2.86 40 3.00 0.00 2.4"Dia x 12-ft Pipe B From Leg 4.00 0.0000 171.00 No Ice 2.86 2.86 40 3.00 0.00 2.4"Dia x 12-ft Pipe C From Leg 4.00 0.0000 171.00 No Ice 2.86 2.86 40 3.00 0.00 (2)L2 1/2x2 1/2x1/4 x 4'-4" A From Leg 2.00 0.0000 171.00 No Ice 1.68 1.68 18 0.00 0.00 (2)L2 1/2x2 1/2x1/4 x 4'-4" B From Leg 2.00 0.0000 171.00 No Ice 1.68 1.68 18 0.00 0.00 (2)L2 1/2x2 1/2xl/4 x 4'4" C From Leg 2.00 0.0000 171.00 No Ice 1.68 1.68 18 0.00 0.00 Sector Mount[SM 503-3] C None 0.0000 171.00 No Ice 33.64 33.64 1691 **160** CAP-FRO-656 w/Mount A From Leg 4.00 -60.0000 160.00 No Ice 5.09 5.01 40 Pipe 7.00 Page tnxi wer Job Pasco County(VS) (BU 826548) 20 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX:(919)661-6350 mfrank Description Face Offset Offsets: A=imuth Placement CaA, Q A.4 Weight or Type Hor Adjustment Front Side Leg Lateral Vert ft 0 ft ft2 fr' 16 ft ft 0.00 CAP-FRO-656 w/Mount B From Leg 4.00 0.0000 160.00 No Ice 5.09 5.01 40 Pipe -7.00 0.00 CAP-FRO-656 w/Mount C From Leg 4.00 -40.0000 160.00 No Ice 5.09 5.01 40 Pipe 7.00 0.00 (2)MX06FRO860-02 w/ A From Leg 4.00 -60.0000 160.00 No Ice 8.84 7.49 112 Mount Pipe -3.00 0.00 (2)MX06FRO860-02 w/ B From Leg 4.00 0.0000 160.00 No Ice 8.84 7.49 112 Mount Pipe 3.00 0.00 (2)MX06FRO860-02 w/ C From Leg 4.00 -40.0000 160.00 No Ice 8.84 7.49 112 Mount Pipe -3.00 0.00 (2)RRUS 32 A From Leg 4.00 -60.0000 160.00 No Ice 2.86 1.78 55 2.00 0.00 (2)RRUS 32 B From Leg 4.00 0.0000 160.00 No Ice 2.86 1.78 55 2.00 0.00 (2)RRUS 32 C From Leg 4.00 -40.0000 160.00 No Ice 2.86 1.78 55 2.00 0.00 RRFDC-3315-PF-48 A From Leg 4.00 -60.0000 160.00 No Ice 3.36 2.19 21 2.00 0.00 2.4"Dia.x 6-ft A From Leg 4.00 0.0000 160.00 No Ice 1.43 1.43 22 -2.00 0.00 2.4"Dia.x 6-ft B From Leg 4.00 0.0000 160.00 No Ice 1.43 1.43 22 -2.00 0.00 2.4"Dia.x 6-ft C From Leg 4.00 0.0000 160.00 No Ice 1.43 1.43 22 -2.00 0.00 Site Pro I VFAI4-HD A From Leg 2.00 0.0000 160.00 No Ice 14.40 9.20 672 0.00 0.00 Site Pro I VFA14-HD B From Leg 2.00 0.0000 160.00 No Ice 14.40 9.20 672 0.00 0.00 Site Pro 1 VFA14-HD C From Leg 2.00 0.0000 160.00 No Ice 14.40 9.20 672 0.00 0.00 **148** APXVERR18-C w/Mount A From Leg 4.00 0.0000 148.00 No Ice 8.26 6.95 76 Pipe 0.00 1.00 APXVERRI8-C w/Mount B From Leg 4.00 0.0000 148.00 No Ice 8.26 6.95 76 Pipe 0.00 1.00 APXVERR18-C w/Mount C From Leg 4.00 0.0000 148.00 No Ice 8.26 6.95 76 Pipe 0.00 1.00 AIR 6488 B41 w/Mount Pipe A From Leg 4.00 0.0000 148.00 No Ice 6.20 3.54 127 WxT®weer Job Pasco County(VS) (BU 826548) Page21 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC27603 Client Designed by Phase:(919)661-6351 Crown Castle FAX.-(919)661-6350 mfrank Description Face Offset Offsets: Azimuth Placement ( aAA CAA Weight or Type Hor- Adjustment Front Side Leg Lateral Vert ft 0fr fr' ft-' lb ft ft 6.00 1.00 AIR 6488 B41 w/Mount Pipe B From Leg 4.00 0.0000 148.00 No Ice 6.20 3.54 127 6.00 1.00 AIR 6488 B41 w/Mount Pipe C From Leg 4.00 0.0000 148.00 No Ice 6.20 3.54 127 6.00 1.00 RRUS 31 B25 A From Leg 4.00 0.0000 148.00 No Ice 1.62 1.28 56 0.00 2.00 RRUS 31 B25 B From Leg 4.00 0.0000 148.00 No Ice 1.62 1.28 56 0.00 2.00 RRUS 31 B25 C From Leg 4.00 0.0000 148.00 No Ice 1.62 1.28 56 0.00 2.00 RRUS 1 I A From Leg 4.00 0.0000 148.00 No Ice 2.79 1.19 51 0.00 2.00 RRUS I 1 B From Leg 4.00 0.0000 148.00 No Ice 2.79 1.19 51 0.00 2.00 RRUS I 1 C From Leg 4.00 0.0000 148.00 No Ice 2.79 1.19 51 0.00 2.00 (3)ACU-A20-N A From Leg 4.00 0.0000 148.00 No Ice 0.07 0.12 1 0.00 2.00 (3)ACU-A20-N B From Leg 4.00 0.0000 148.00 No Ice 0.07 0.12 1 0.00 2.00 (3)ACU-A20-N C From Leg 4.00 0.0000 I48.00 No Ice 0.07 0.12 1 0.00 2.00 800MHz SMR Filter A From Leg 4.00 0.0000 148.00 No Ice 0.65 0.22 9 0.00 2.00 800MHz SMR Filter B From Leg 4.00 0.0000 148.00 No Ice 0.65 0.22 9 0.00 2.00 800MHz SMR Filter C From Leg 4.00 0.0000 148.00 No Ice 0.65 0.22 9 0.00 2.00 2.4"Dia x 8-11 Mount Pipe A From Leg 4.00 0.0000 148.00 No Ice 1.90 1.90 29 -6.00 0.00 2.4"Dia x 8-ft Mount Pipe B From Leg 4.00 0.0000 148.00 No Ice 1.90 1.90 29 -6.00 0.00 2.4"Dia x 8-ft Mount Pipe C From Leg 4.00 0.0000 148.00 No Ice 1.90 1.90 29 -6.00 0.00 Site Pro 1 VFA12-HD A From Leg 2.00 0.0000 148.00 No Ice 13.20 9.20 658 0.00 0.00 Site Pro 1 VFA12-HD B From Leg 2.00 0.0000 148.00 No Ice 13.20 9.20 658 b tnxTower Jo Pasco County(VS) (BU 826548) Page22 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX.-(919)661-6350 mfrank Description Face Offset Offsets: Azimuth Placement CIA,, C,A.4 Weight or Type Hor Adjustment Front Side Leg Lateral Vert ft 0 ft f? fr' lb ft ft 0.00 0.00 Site Pro I VFA12-HD C From Leg 2.00 0.0000 148.00 No Ice 13.20 9.20 658 0.00 0.00 **140** HB-X-AW-23-33-OOT A From Leg 4.00 -60.0000 140.00 No Ice 3.52 3.52 44 6.00 0.00 HB-X-AW-23-33-OOT B From Leg 4.00 -60.0000 140.00 No Ice 3.52 3.52 44 6.00 0.00 HB-X-AW-23-33-OOT C From Leg 4.00 -60.0000 140.00 No Ice 3.52 3.52 44 6.00 0.00 Sector Mount[SM 402-3] A None 0.0000 140.00 No Ice 18.91 18.91 851 Bolt Design Data Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allotivable Criteria No. Type Grade Of Load Load Load Ratio ft in Bolts per Bolt per Bolt Allowable lb lb Tl 190 Leg A325N 0.7500 4 3089 30101 0.103 1.05 Bolt Tension Diagonal A325N 0.5000 2 2190 4996 0.438 1.05 Member Block Shear Top Girt A325N 0.5000 l 1833 8265 0.222 1.05 Member Bearing T2 180 Leg A325N 0.8750 4 14779 41556 0.356 1.05 Bolt Tension Diagonal A325N 0.5000 2 4286 5505 0.778 1.05 Member Block Shear Top Girt A325N 0.5000 1 52 8265 0.006 1.05 Member Bearing T3 160 Leg A325N 1.0000 6 19340 54517 0.355 1.05 Bolt Tension Diagonal A325X 0.7500 1 11198 17944 0.624 1.05 Member Block Shear Top Girt A325N 0.7500 1 291 18923 0.015 1.05 Member Bearing T4 140 Leg A325N 1.5000 4 45416 126472 0.359 1.05 Bolt Tension Diagonal A325N 0.6250 2 6213 7697 0.807 1.05 Member Block Shear Top Girt A325N 0.6250 1 3242 13806 0.235 1.05 Bolt Shear T5 120 Diagonal A325N 0.6250 2 6341 7697 0.824 1.05 Member Block Shear Top Girt A325N 0.6250 1 2434 13806 0.176 1.05 Bolt Shear T6 113.333 Diagonal A325N 0.6250 2 6485 7697 0.842 1.05 Member Block Shear T7 106.667 Leg A325N 1.5000 6 40751 126472 0.322 1.05 Bolt Tension Diagonal A325X 0.6250 2 7045 15395 0.458 1.05 Member Block Shear T8 100 Leg A325N 1.5000 6 50075 126472 0.396 1.05 Bolt Tension Diagonal A325N 0.7500 2 8403 12506 0.672 1.05 Member Block Shear Job Page Wx7'ower Pasco County(VS) (BU 826548) 23 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX. (919)661-6350 Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable Criteria No. Type Grade Of Load Load Load Ratio ft in Bolts per Bolt per Bolt Allowable lb lb Top Girt A325N 0.7500 1 4486 18923 0.237 1.05 Member Bearing T9 80 Diagonal A325N 0.6250 2 8056 11623 0.693 1.05 Member Block Shear Top Girt A325N 0.6250 1 4518 13050 0.346 1.05 Member Bearing T10 70 Leg A325N 1.5000 6 60023 126472 0.475 1.05 Bolt Tension Diagonal A325X 0.6250 2 9145 23245 0.393 1.05 Member Block Shear T11 60 Leg A325N 1.5000 6 69826 126472 0.552 1.05 Bolt Tension Diagonal A325N 0.7500 2 9603 18759 0.512 1.05 Member Block Shear Top Girt A325N 0.7500 1 6118 15769 0.388 1.05 Member Bearing T12 40 Diagonal A325N 0.7500 2 9062 18759 0.483 1.05 Member Block Shear Top Girt A325N 0.7500 1 5742 15769 0.364 1.05 Member Bearing T13 30 Leg A325N 1.5000 6 79347 126472 0.627 1.05 Bolt Tension Diagonal A325X 0.7500 2 10485 33495 0.313 1.05 Gusset Bearing T14 20 Diagonal A325N 0.7500 2 10726 18759 0.572 1.05 Member Block Shear Top Girt A325N 0.7500 1 6103 15769 0.387 1.05 Member Bearing Compression Checks Leg Design Data (Compression) Section Elevation Size L L„ Kl/r A P„ �P„ Ratio No. P. ft ft ft in1 lb lb �1`11 T1 190-180 Pipe 2.5 STD 10.00 5.00 63.3 1.7040 -17571 53866 0.326' K=1.00 T2 180-160 PIPE 3.5 STD 20.00 5.00 44.9 2.6795 -69472 96872 0.717' K=1.00 T3 160-140 Pipe 5 STD 20.02 6.67 42.7 4.2974 -133919 157400 0.851 ' K=1.00 T4 140-120 Pipe 8 STD 20.02 6.67 27.3 8.3993 -205737 330771 0.622' K=1.00 T5 120-113.333 Pipe 8 STD 6.67 6.67 27.3 8.3993 -229038 330771 0.692' K=1.00 T6 113.333- Pipe 8 STD 6.67 6.67 27.3 8.3993 -252610 330771 0.764' 106.667 K=1.00 T7 106.667-100 Pipe 8 STD 6.67 6.67 27.3 8.3993 -274177 330771 0.829' K=1.00 T8 100-80 Pipe 10 STD(SCH40) 20.02 10.01 32.5 11.9656 -336355 461312 0.729' K=1.00 T9 80-70 Pipe 10 STD(SCH40) 10.01 10.01 32.5 11.9656 -369915 461312 0.802' K=1.00 T10 70-60 Pipe 10 STD(SCH40) 10.01 10.01 32.5 11.9656 -403034 461312 0.874' K=1.00 Tll 60-40 Pipe 12STD 20.02 10.01 27.4 14.5790 -470040 573746 0.819' K=1.00 T12 40-30 Pipe 12 STD 10.01 10.01 27.4 14.5790 -503079 573746 0.877' K=1.00 T13 30-20 Pipe 12 STD 10.01 10.01 27.4 14.5790 -535678 573746 0.934' tIZxTowef Job Pasco County(VS) (BU 826548) Page24 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX:(919)661-6350 Section Elevation Size L L„ KI1r A P. Ratio No. P. ft ft ft ins lb Ib K=1.00 T14 20-0 Pipe 12 XH 2O.02 10.01 27.7 19.2423 -601377 756510 0.795' K=1.00 'P„ /�P„controls Diagonal Design Data Compression Section Elevation Size L L„ KI/r A P �P„ Ratio No. P. ft ft ft in lb lb W, T1 190-180 L1 3/4xl 3/4x3/16 9.43 4.41 146.0 0.6211 -4397 8341 0.527' K=0.95 T2 180-160 L2x2x3/16 9.43 4.35 129.6 0.7150 -8657 12176 0.711 ' K=0.98 T3 160-140 2L2 1/2x2 1/20/160/8 11.52 5.51 85.0 1.8000 -12126 50089 0.242' K=1.00 T4 140-120 L3x3x3/16 12.91 6.00 120.7 1.0900 -12644 21145 0.598' K=1.00 T5 120-113.333 L3x3x3/16 13.39 6.24 124.4 1.0900 -12912 20094 0.643' K=0.99 T6 113.333- L3x3x3/16 13.87 6.49 128.1 1.0900 -12830 19000 0.675' 106.667 K=0.98 T7 106.667-100 2L3x3x3/16xl/2 14.36 6.74 86.0 2.1797 -14442 58762 0.246' K=1.00 T8 100-80 L3 1/20 1/2x1/4 17.41 8.18 136.4 1.6900 -16971 26003 0.653' K=0.96 T9 80-70 L31/201/2xl/4 18.10 8.56 141.4 1.6900 -16357 24191 0.676' K=0.96 T10 70-60 2L31/201/2xl/4xl/2 18.80 8.92 98.0 3.3750 -18615 84780 0.220' K=1.00 Tll 60-40 L31/201/2x3/8 20.23 9.51 155.2 2.4800 -19425 29456 0.659' K=0.93 T12 40-30 L3 1/20 MOM 20.96 9.88 160.1 2.4800 -18445 27681 0.666' K=0.93 T13 30-20 2L3 1/20 1/2x3/8xl/2 21.69 10.25 114.6 4.9688 -21447 105031 0.204` K=1.00 T14 20-0 L4x4x3/8 23.19 11.01 156.3 2.8600 -21780 33503 0.650' K=0.93 P„ /�P„controls Top Girt Design Data (Compression) Section Elevation Size L L„ KI/r A P. Ratio No. P. ft ft ft in2 lb lb VP Tl 190-180 L3 1/20 1/2xl/4 8.00 7.55 130.6 1.6900 -1851 28367 0.065' K=1.00 T2 180-160 L3 1/20 1/2x1/4 8.00 7.55 130.6 1.6900 -7 28367 0.000' K=1.00 inx3'Qwer Job Pasco County(VS) (BU 826548) Page25 of 27 Tower Engineering Project Date Professionals TEP No. 48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX.-(919)661-6350 Section Elevation Sire L L„ Kl/r A P. Ratio No. P. ft ft ft in lb lb W, T3 160-140 L3 1/2x3 1/2x3/8 8.00 7.40 129.2 2.4800 -85 42533 0.002' K=1.00 T4 140-120 L3 1/2x3 1/2x3/8 9.67 8.96 156.6 2.4800 -2635 28955 0.091 ' K=1.00 T5 120-113.333 L4x4x3/8 11.33 10.38 158.0 2.8600 -2088 32793 0.064' K=1.00 T8 100-80 L4x4x3/8 13.00 12.01 182.9 2.8600 -4063 24470 0.166' K=1.00 T9 80-70 L5x5x5/16 14.67 13.53 163.3 3.0300 -4225 32519 0.130' K=1.00 Tl 1 60-40 L5x5x5/16 16.33 15.16 183.0 3.0300 -5713 25883 0.221 ' K=1.00 T12 40-30 L5x5x5/16 18.00 16.67 201.2 3.0300 -5364 21422 0.250' K=1.00 KL/R>200(C)-187 T14 20-0 L5x5x5/16 19.67 18.33 221.3 3.0300 -5614 17704 0.317' K=1.00 KL/R>200(C)-208 1 P„ /¢P controls Tension Checks Leg Design Data (Tension) Section Elevation Sire L L„ Kl/r A P �P Ratio No. P„ jt ft ft in' lb lb Tl 190-180 Pipe 2.5 STD 10.00 5.00 63.3 1.7040 12355 70548 0.175' T2 180-160 PIPE 3.5 STD 20.00 5.00 44.9 2.6795 59115 110933 0.533' T3 160-140 Pipe 5 STD 20.02 6.67 42.7 4.2974 116040 177914 0.652' T4 140-120 Pipe 8 STD 20.02 6.67 27.3 8.3993 181664 347729 0.522' T5 120-113.333 Pipe 8 STD 6.67 6.67 27.3 8.3993 202998 347729 0.584' T6 113.333- Pipe 8 STD 6.67 6.67 27.3 8.3993 224433 347729 0.645' 106.667 T7 106.667-100 Pipe 8 STD 6.67 6.67 27.3 8.3993 244504 347729 0.703 ' T8 100-80 Pipe 10 STD(SCH40) 20.02 10.01 32.5 11.9656 300449 495377 0.607' T9 80-70 Pipe 10 STD(SCH40) 10.01 10.01 32.5 11.9656 330526 495377 0.667' T10 70-60 Pipe 10 STD(SCH40) 10.01 10.01 32.5 11.9656 360140 495377 0.727' Tl 1 60-40 Pipe 12 STD 20.02 10.01 27.4 14.5790 418957 603569 0.694' T12 40-30 Pipe 12 STD 10.01 10.01 27.4 14.5790 447769 603569 0.742' T13 30-20 Pipe 12 STD 10.01 10.01 27.4 14.5790 476079 603569 0.789' T14 20-0 Pipe 12 XH 2O.02 10.01 27.7 19.2423 531922 796629 0.668' P„ /�P„controls Diagonal Design Data (Tension) b W xToweY Jo Pasco County(VS) (BU 826548) Page26 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC27603 Client Designed by Phone:(919)661-6351 Crown Castle mfrank FAX.•(919)661-6350 Section Elevation Sire L L„ Kl/r A P� Ratio No. P. jt ft ft in' lb /6 W, Tl 190-180 LI 3/4xl 3/4x3/16 9.43 4.41 102.3 0.3779 4380 16440 0.266' T2 180-160 L2x2x3/16 9.43 4.35 87.9 0.4484 8571 19504 0.439' T3 160-140 2L2 I/2x2 1/2x3/16x3/8 11.52 5.51 87.1 1.1039 11198 48020 0.233' T4 140-120 L3x3x3/16 12.91 6.00 79.2 0.7120 12426 30973 0.401 ' T5 120-113.333 L3x3x3/16 13.39 6.24 82.3 0.7120 12682 30973 0.409` T6 113.333- L3x3x3/16 13.87 6.49 85.4 0.7120 12969 30973 0.419' 106.667 T7 106.667-100 2L3x3x3/16x1/2 14.36 6.74 88.6 1.4238 14089 61937 0.227' T8 100-80 L3 1/20 1/2x1/4 17.41 8.18 92.6 1.1034 16805 48000 0.350' T9 80-70 L3 1/2x3 1/2x1/4 18.10 8.56 96.4 1.1269 16113 49019 0.329' TIO 70-60 21-31/201/2xI/4x1/2 18.80 8.92 100.2 2.2500 18290 97875 0.187' TI I 60-40 L3 1/20 I/2x3/8 20.23 9.51 109.3 1.6139 19206 70205 0.274' T12 40-30 L3 I/2x3 1/2x3/8 20.96 9.88 113.4 1.6139 18123 70205 0.258' T13 30-20 2L31/20I/2x3/8x1/2 21.69 10.25 117.1 3.2344 20971 140695 0.149' T14 20-0 L4x4x3/8 23.19 11.01 109.6 1.8989 21452 82602 0.2601 P„ /�P controls Top Girt Design Data (Tension) Section Elevation Size L L„ K11r A P pP Ratio No. P ft ft ft in 1 lb lb WP TI 190-180 L3 I/2x3 1/2xI/4 8.00 7.55 85.4 1.1503 1833 50039 0.037' T2 180-160 L3 I/2x3 I/2xI/4 8.00 7.55 85.4 1.1503 52 50039 0.001 ' T3 160-140 L3 1/2x3 1/2x3/8 8.00 7.40 86.0 1.6139 291 70205 0.004` T4 140-120 L3 I/2x3 I/2x3/8 9.67 8.96 103.2 1.6491 3242 71734 0.045' T5 120-113.333 L4x4x3/8 11.33 10.38 103.6 1.9341 2434 84132 0.029' T8 100-80 L4x4x3/8 13.00 12.01 119.8 1.8989 4486 82602 0.054' T9 80-70 L5x5x5/16 14.67 13.53 105.2 2.0967 4518 91207 0.050' Tl 1 60-40 L5x5x5/16 16.33 15.16 118.0 2.0674 6118 89933 0.068` T12 40-30 L5x5x5/16 18.00 16.67 129.5 2.0674 5742 89933 0.064' T14 20-0 L5x5x5/16 19.67 18.33 142.2 2.0674 6103 89933 0.068' P„ /�P controls Section Capacity Table Section Elevation Component Size Critical P op�//",. % Pass No. .lt Type Element lb lh Capacity Fail Tl 190-180 Leg Pipe 2.5 STD 2 -17571 56559 31.1 Pass 72 180-160 Leg PIPE 3.5 STD 21 -69472 101716 68.3 Pass T3 160-140 Leg Pipe 5 STD 51 -133919 165270 81.0 Pass T4 140-120 Leg Pipe 8 STD 75 -205737 347310 59.2 Pass T5 120-113.333 Leg Pipe 8 STD 99 -229038 347310 65.9 Pass T6 113.333- Leg Pipe 8 STD 111 -252610 347310 72.7 Pass 106.667 T7 106.667-100 Leg Pipe 8 STD 120 -274177 347310 78.9 Pass T8 100-80 Leg Pipe 10 STD(SCH40) 129 -336355 484378 69.4 Pass T9 80-70 Leg Pipe 10 STD(SCH40) 147 -369915 484378 76.4 Pass T10 70-60 Leg Pipe 10 STD(SCH40) 159 -403034 484378 83.2 Pass Job W xTower Jo Pasco County(VS) (BU 826548) Page27 of 27 Tower Engineering Project Date Professionals TEP No.48167.283829 15:26:24 07/22/19 326 Tryon Road Raleigh,NC27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX.-(919)661-6350 mfrank Section Elevation Component Size Critical P oPo/1,,,,. % Pass No. ft Type Element lb lb Capacity Fail T11 60-40 Leg Pipe 12 STD 168 -470040 602433 78.0 Pass T12 40-30 Leg Pipe 12 STD 186 -503079 602433 83.5 Pass T13 30-20 Leg Pipe 12 STD 198 -535678 602433 88.9 Pass T14 20-0 Leg Pipe 12 XH 207 -601377 794335 75.7 Pass TI 190-180 Diagonal Ll 3/4xl 3/4x3/16 8 -4397 8758 50.2 Pass T2 180-160 Diagonal L2x2x3/16 27 -8657 12785 67.7 Pass 74.1(b) T3 160-140 Diagonal 2L2 1/2x2 1/20/160/8 58 -12126 52593 23.1 Pass 59.4(b) T4 140-120 Diagonal L3x3x3/16 84 -12644 22202 57.0 Pass 76.9(b) T5 120-113.333 Diagonal L3x3x3/16 108 -12912 21099 61.2 Pass 78.5(b) T6 113.333- Diagonal L3x3x3/16 117 -12830 19950 64.3 Pass 106.667 80.2(b) T7 106.667-100 Diagonal 2L3x3x3/16xl/2 126 -14442 61700 23.4 Pass 43.6(b) T8 100-80 Diagonal L3 1/20 1/2xl/4 138 -16971 27303 62.2 Pass 64.0(b) T9 80-70 Diagonal L3 1/2x3 1/2xl/4 156 -16357 25401 64.4 Pass 66.0(b) T10 70-60 Diagonal 2L3 1/20 1/2xl/4xl/2 165 -18615 89019 20.9 Pass 37.5(b) T11 60-40 Diagonal L31/201/2x3/8 177 -19425 30929 62.8 Pass T12 40-30 Diagonal L3 1/2x3 1/2x3/8 195 -18445 29065 63.5 Pass T13 30-20 Diagonal 2L3 1/20 1/2x3/8xl/2 204 -21447 110283 19.4 Pass 29.8(b) T14 20-0 Diagonal IAx4x3/8 216 -21780 35179 61.9 Pass Tl 190-180 Top Girt L3 1/20 1/2xl/4 6 -1851 29785 6.2 Pass 21.1(b) T2 180-160 Top Girt L3 1/20 1/2xl/4 23 44 52541 0.2 Pass 0.6(b) T3 160-140 Top Girt L3 1/2x3 1/2x3/8 52 291 73715 0.4 Pass 1.5(b) T4 140-120 Top Girt L3 1/20 MOM 76 -2635 30403 8.7 Pass 22.4(b) T5 120-113.333 Top Girt 14x4x3/8 100 -2088 34432 6.1 Pass 16.8(b) T8 100-80 Top Girt L4x4x3/8 130 -4063 25694 15.8 Pass 22.6(b) T9 80-70 Top Girt L5x5x5/16 148 -4225 34145 12.4 Pass 33.0(b) T11 60-40 Top Girt L5x5x5/16 169 -5713 27177 21.0 Pass 37.0(b) T12 40-30 Top Girt L5x5x5/16 187 -5364 22493 23.8 Pass 34.7(b) T14 20-0 Top Girt L5x5x5/l6 208 -5614 18589 30.2 Pass 36.9(b) Summary Leg(T13) 88.9 Pass Diagonal 80.2 Pass (T6) Top Girt 37.0 Pass (T11) Bolt Checks 80.2 Pass RATING= 88.9 Pass Program Version 8.0.5.0-11/28/2018 File:C:/Users/mfrank/Desktop/tnx/826548-Pasco County(VS)/826548_1726765_LC7.eri July 22,2019 190-ft Self Supporting Tower Structural Analysis Report CCI BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 9 APPENDIX B BASE LEVEL DRAWING tnxTower Report-version 8.0.5.0 1 (OTHER CONSIDERED EQUIPMENT) (1) 1-1/4'TO 160 FT LEVEL (PROPOSED EQUIPMENT CONFlGURATION) (12) 1-5/8'TO 160 FT LEVEL (3) 1-1/4'TO 148 FT LEVEL LEG •••••••41100 OOO LEG ® O (OTHER CONSIDERED EQUIPMENr) • �O (OTHER CONSIDERED EQUIPMENT) (3)5/16o TO 1711 FT LEVEL (6) 1-5/8'TO 140 FT LEVEL • (3)3/8'TO 171 FT4 TO 7 FT LEVEL LEVEL (6)7/8'TO 171 FT LEVEL • • (12) 1-5/8'TO 171 FT LEVEL • • OTHER CONSIDERED EQUIPMENT) 1) 1-1/PTO 190 FT LEVEL (1) 1-3/5'TO 190 FT LEVEL O (12) 1-5/8'TO 190 FT LEVEL • LEG B BUSINESS UN1T:826548 TOWER ID:C-BASELEVEL July 22,2019 190-ft Self Supporting Tower Structural Analysis Report M BU No 826548 TEP Project Number 48167.283829, Order 449759, Revision 2 Page 10 APPENDIX C ADDITIONAL CALCULATIONS tnxTower Report-version 8.0.5.0 An damp Aman. ASCE 7 Hazards Report AMERICAN SOCIETY GF CIVIL ENGINEERS Address: Standard: ASCE/SEI 7-10 Elevation: 91 ft(NAVD 88) No Address at This Risk Category: 11 Latitude: 28.248028 Location Soil Class: D-Stiff Soil Longitude: -82.185944 �~�;i"r .�: .•-i�,•" ;yam? «�� i�" ,,�,ram;' J - e�a.r `f park « .'f .= ter, Psi t �..z_1... A- P,d„ ''''`�f`'.�'� %tF'tz;_-�f°; "'�'- .. S 2� �i=�i :sa � _ ,s•opx3lrag t ,\J .• ,3 ��y,ter..„—., d €._' ...y,�� ....�:..' _!'?'1'-'P•d ."TNn..b�nm - .1= �''q s \. 1•, �CilC3ef'S?`dr{(s"?$q�: y . '' ;Y•^p+' ,: A v 2a -,limr`h . s;-?''' T ��, '.`•� s'i ,,y.[^a'^:.'rc.,.t°"�as_,.,t`_ [Y. "$.•�... - 'i C:i[a _ '� Wind Results: Wind Speed: 137 Vmph 10-year MRI 78 Vmph 25-year MRI 93 Vmph 50-year MRI 104 Vmph 100-year MRI 114 Vmph Data Source: ASCE/SEI 7-10, Fig.26.5-1A and Figs. CC-1—CC-4, incorporating errata of March 12, 2014 Date Accessed: Tue Mar 26 2019 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard.Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability= 0.00143, MRI = 700 years). Site is in a hurricane-prone region as defined in ASCE/SEI 7-10 Section 26.2. Glazed openings need not be protected against wind-borne debris. Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind conditions. httos://asce7hazardtool.online/ Page 1 of 3 Tue Mar 26 2019 ASCE, AMRGAN SOGIUY OF GML ENGINUS Seismic Site Soil Class: D-Stiff Soil Results: Ss : 0.068 Sos 0.072 S, 0.034 Sol 0.055 Fa 1.6 TL 8 F 2.4 PGA: 0.032 SMs 0.108 PGA M : 0.051 SMi 0.083 FPGA 1.6 le 1 Seismic Design Category A D 11 MCER Response Spectrum_ D D Design Response Spectrum —i'N D070� ( _ m m.. , 0.08 0 06--A . 0.06 D Oa 0.04— _-.. ..___ ._.___.:.- ____.- . .... .._ _.._._____ 0.03- 0.03. ..: 0 02 - 0.02. 0.01 h _ .. 0.01 QI= F 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 Sa(9)vs T(s) Sa(9)vs T(s) Data Accessed: Tue Mar 26 2019 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-10 Ch. 21 are available from USGS. httos://asce7hazardtool.online/ Page 2 of 3 Tue Mar 26 2019 ASCE' AMEREM SOCIM OFCML EN6INEMS Ice Results: Ice Thickness: 0.00 in. Concurrent Temperature: 25 F Gust Speed: 30 mph Data Source: Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8 Date Accessed: Tue Mar 26 2019 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience,for informational purposes only,and is provided"as is"and without warranties of any kind.The location data included herein has been obtained from information developed,produced,and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard.While ASCE has made every effort to use data obtained from reliable sources or methodologies,ASCE does not make any representations or warranties as to the accuracy,completeness,reliability, currency,or quality of any data provided herein.Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,relationship,or sponsorship of such third-party content by or from ASCE. ASCE does not intend,nor should anyone interpret,the results provided by this Tool to replace the sound judgment of a competent professional,having knowledge and experience in the appropriate field(s)of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool,you expressly assume all risks associated with your use.Under no circumstances shall ASCE or its officers,directors, employees,members,affiliates,or agents be liable to you or any other person for any direct,indirect,special,incidental,or consequential damages arising from or related to your use of,or reliance on,the Tool or any information obtained therein.To the fullest extent permitted by law,you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. httos://asce7hazardtool.online/ Page 3 of 3 Tue Mar 26 2019 (ECOPhU Project1 1 BU# 826548 Site Name Pasco County(VS) Order# 449759 Rev. 2 Jower Information Tower Type I Self Support TIA-222 RevJ H Q Apply TIA-222-H Section 15.5 Applied Loads, Comp. Uplift Axial(k) 618.44' " 546.57 Shear(k) 60.87 54:80 Anchor Rod 1 Data Quantity: 6 Diameter(in): 2.25 Material Grade: A615-75 Fy=75 ksi Fu=100 ksi Grout Considered: No lar(in): 2.625 Eta Factor, g: 1 ;i,k ' Thread Type: N-Included Configuration: Symmetrical jAnchor • 1 1 Results Axial, Pu_c(kips) 103.07 Shear,Vu (kips) 10.15 Moment, Mu (kip-in) 17.31 Axial Cap., cDPn_c(kips) 243.75 Shear Cap., (�Vn (kips) 73.13 Moment Cap., (�Mn (kip-in) 94.70 Stress Rating 59.5% Pass CClplate-version 3.6.0 Analysis Date:7/22/2019 Drilled Pier Foundation 1826548 CROWN Site=. CASTLE Order Number:1449759 Rev.2 TIA-222 Revison: H Tower Type:L Self Support Analysis Results Check YiBYiii Limitation Applied'Loads Soil Lateral CI Compression Upfill Apply TIA-222-H Section 1 5.5:F--� Moment I Comp. Uplift -D,.c�ft from TOC)1 20,76 20.76 1 NIA l:,, Soil Safety Factor 17.39 9 Axial Force 546.573 Max moment(kit)7ft) 851.76 4t 15 Shear Force(kips)1 60.871 54.798 11 1 1 Rating'"1 7.3% Soil Vertical Capacity Compression uplift Material Properties Skin Friction(kips) 7K61 566.19 Strength,Concrete fc:I 41ksi End Bearing(kips) 406.73 - Rebar Strength,Fy:1, 601ksi Weight of Concrete(kips) 216.30 162,22 Total Capacity(kips) 1191.34 728.42 Pier Design Data Axial(kips) 834.74 546.57 Depth I it Rating* 66.7% 71.5% Ext.Above Grade l 0.51ft Reinforced Concrete Capacity Compression uplift Pier Section I Critical Depth(ft from TOC) 21.40 19.02 From 0.Fabove grade to 42'below grade Critical Moment(kip-ft) 850.57 759.14 Pier Diameter 61ft Critical Moment Capacit 4516.61 2762.28 Rebar Quantity 26 Rating* 17.9% 26.2% Rebar Size 9 Clear Cover to Ties 3 in Soil Interaction Rating"- 71.6% Tie Size 4 Structural Foundation Rating" 26.2% *Rating per TIA-222-H Section 15.5 Soil Profile Groundwater-Depth i n/a ift #of Layers I - 5 Angle of., Calculated Calculated. Ultimate Skin Ultimate Skin- Ult.Gross To p Bottom -'Thickness V,�ji y_ Cohesion Ultimate Skin Ultimate Skin Friction Comp Bearing:. SPT.Blow yer Friction La (it) (pd) (pcf) Friction Comp Friction Uplift Override Friction Uplift. Soil Type' (it) (ft) (ksf) d � Capacity Count' . ,'.' '(degrees)' (ksf) (ksf) (ksf) Overricle'l[lisf) (ksf) 1 0 3 3 110 150 0 0.000 0.000 0,00 - '0.00 Cohesionless 2 3 12 9 110 150 30 0.000 '0.000 0.50- 0,35 Cohesionless 31 12 ' 3611 1581 100 l 6 1651 150 251 0.0001 0.000 1.501, 1.05 ----TCohesionless 4 50 4 1 1 ig 01 0.51 101-- 0,6891- 0.689 2,001 1!501 ty 51 401 421 21 1001 1501 '0;51 101' 0.7451' 0.7451, 2,001' 1.501 19,18 1 Silty Version 2.1.1 Eltt5501 Steve Nichols E-mail: steve.nichols@ericsson.com Tel: 352-446-1241 CONTRACTORS LIMITED POWER OF ATTORNEY Company Name: Ericsson Site/Permit#38122 Henry Dr. Zeplzyrhills, Ff To Whom It May Concern: Please accept this -letter as a "Limited Power of Attorney," that I hereby authorize the below listed individual(s) to pick up any necessary documents(s) required for any Building or Zoning Type Permits, that may be required for the above property. AUTHORIZED AGENUS): • Ariel Buffington j;;m CO�F e,q • S4" 61 rc v-e S Should you have any qjionlesasedo not hesitate to contact me at 352-446-1241. Thank you, Qualifier's Signature: Print Name: Contractor#: CGC1518237 Sworn and subscribed to me before this day of 19 by Steven HNichols Who did take the oath is personally known t a Notary Public: Notary Seal STEPHANI WRIGHTSON +; = MY COMMISSION#GG 342734 oRo�°`•' EXPIRES:June 27,2023 Bonded Thru Notary Publlc Underwtltera