Loading...
HomeMy WebLinkAbout19-21767 CITY OF ZEPHYRHILLS 5335-8TH STREET % (813)780-0020 21767 t FIRE STANDPIPES PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 21767 Address: 5347 GALL BLVD Permit Type: FIRE HOOD SUPPRESSION SYS ZEPHYRHILLS, FL. Class of Work: FIRE-HOOD SUPPRESSION SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est.Value: Parcel Number: 11-26-21-0010-12200-0090 Improv. Cost: 2,350.00 OWNER INFORMATION Date Issued: 2/20/2020 Name: ZEINELABDIN, FATUMA Total Fees: 235.00 Address: 11730 MOFFATT AVE Amount Paid: 235.00 TAMPA, FL 33617 Date Paid: 2/20/2020 Phone: 813-382-5788 Work Desc: INSTALLATION SUPPRESSION SYSTEM HOOD CONTRACTORS APPLICATION FEES STATE FIRE PROTECTON ING FIRE SUPPRESSION 50.00 FIRE PLAN REVIEW FEES 50.00 L.D.H ELECTRICAL SERVICE FIRE INSPECTION FEES 30.00 CONTRACTOR CERTIFICATE `20(7"Z20 30.00 CONTRACTOR CERTIFICATE; 4016-7tJ930.00 ELECTRICAL FEE 45.00 c Ins ections Required FIRE BALLOON TEST-Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME MENT " CONTRAC 7PIER NATURE PERMIT OFFIC60IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received ` _ Phone Contact for Permit Owners Name' -�S/✓�� S�/}rD d A Owner's Phone Number Owners Address - 2J / 11l�1)f✓ Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address / !� Job Address � G, l 3 4 Lot# F Sub Division Parcel# BT_ ED-�FR NL-eR EERTY A.-. i•E —� 'Bio-Hazard Waste Storage-ANNUAL Fumigation Tent 5a Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum Hood Installation Emergency Generator<30 kw LP/Natural Gas-Installatior '2 r Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale (Jt EDFire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL Qtri-yj rS—em—ij Anl Other Sprinkler ❑ ❑ ❑ Recreational Bum Fire Alarm ❑ ❑ ❑ Sparklers Hood Cleaning ❑� ❑ ❑ � � Sprinkler System Installations Y �Hood Suppression El ❑ ❑ ElStandpipes(Sprinkler Sys) C i Fire Alarm Installation � Torch Roofing/Tar Kettle ��� ��Fire Pumps Waste Tire Storage ANNUAL n, Flammable Application-ANNUAL ? d e ® Valuation of Project Fuel Tanks 0 Other: Contractor ' Company Signature Registered Y/N Fee Current I Y/N Address License# O OaO 31 aj ELECTRICIAN /10�r /)V t^ Company TowLfeC7��ta ���icL Signature 4� p !' /5 > Registered Y/N Fee Current Address I Y10 /' License# C[- 3 0 o Z 03 PLUMBER I Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current Address License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that ithis permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the °Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and,Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable) laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to d meet standards of all laws regulating construction, County;and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I'am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months afterithe time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed andb bsworn to(or affirmed)before me this Subscribed and sbwo irmed)b� met is Y Y Who is/are personally known to me or has/have produced Who is/are personally known 6,me or has/h ve produced as identification. ! identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped O r"'rot City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: y Date Received: 9-4— jq Site: 530 Permit Type: �� �s� / CS C �J Approved w/no comments:C Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Gene Brown— ire Safety Officer D to Contractor and/or Homeowner (Required when comments are present) ZEPHYRHILLS FIRE DEPARTMENT 38410 6th Ave Zephyrhills, FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy,No.: Plan No.: Contractor: Business Name: Billing Address: Business.Address:: Business-Phone No.: Billing,Phone No.: '7;,?A-7 -7-77�&q Business Fax.No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual. Education,healthcare,De tention&Correctional Public Assembly,Business, schools, Storage,Mercantile and Churches .Site Plan N/C Industrial. no charge Sprinkler $50 n. Multi-Family/Commercial .03 sf up to 800 sq ft $ 24.00, Standpipes $50 (Minimum Charge'$24.00 801-1,500 sq ft $ 34.52 Fire Pump $50 Plan Revisions DBL, 1,501-2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 0-25-Heads $60 5,501-7,500 sq ft $ .187.52 Natural Gas $50 26,plus.Heads $100 7,501-101'000 sq It $ 262.52 Fuel Tanks- pertank $50 ,STANDPIPE SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 Per Riser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation'' $25 IJ Per Pump $100 30,001-40,000 sq It $ 1,050.02 Controlled Bum(15da: $100 FIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,500.02 Hood/Duct $50 0-25 Devices $50 ,60,001-80,000 sq ft $ 2,100.02 Place of Assembly $50 Annual .00,001-($2,100.02)per 026.plus Devices $100 ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS (Business closed.until Flammable Application $50 Annual Wet $60 violations corrected) Waste Tire Storage $50 Annual Dry $50 ',SPRINKLER SYSTEMS Generator<KW $100 CO2 $50 '.Hydro Undergrounds $45 Generator>30 KW $100 Other $50- Hydrostatic Test $65 per system Blo-Hazard Waste $100 Annual KITCHEN,EXHAUST Acceptance Test $45 per system Fumigation Tenting $50 Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50 Annual 8 LF Installation per tank FIRE ALARM SYSTEM Fuel Tank Installation $50: System Acceptance $50 (Per Tank) $50 H'Recall Acceptance- $50 ❑Natural Gas installation' $50 OTHER (Per System Fine Wall/Smoke Wall $15 perwall Spray Booth $50 LP Gas $25 per tank Natural Gas $25 per system Tent 10'x10'or greater $15 per tent Fire Pump $45 Fire Suppression $30 System Acceptance Exhaust Hood/Duct $30 Re4nspection DBL .(other than-annual) Inspection scheduled, DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $60 PLANS TOTAL f3 INSPECTION TOTAL PERMIT TOTAL' i e5_0 GRAND TOTAL Comments; Date: f9 Inspector: see back nth i i i i I FALSE ALARM FEE 1stAlarm N/C 2nd Alarm N/C 3rd Alarm -N/C 4th Alarm $160 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 'Cont.'Annual Inspection fees 3-11 Units price per unit $ 5,36 12-25'Units price per unit $ 4182 26=50'Units price per unit $ 4!20 51-100 Units price per unit $ I75 100 or more Units price per unit $ 2i68 Fire Safety re-inspection types First Re-inspectiol N/C Second re-inspect-, $75- Third re-inspectior $ "125.00 Inspection scheduled butcanceiled24,hrs $ 50.00 f i I I TOTAL- I r - nm m -„-a 00�p >s OM X mtn }} > CD C t3iLyo z r _ C7 ! t•t �,t�61 �a FOR: 12 t ve),-5 t 06- S e'VCr'do a Was DIUID 1 ) System to be Fyro-Om Nadel # PCL 3 liquid type ULL 300 specificaticn 2) All fuel, and electric under hood to ihut dawn upon discharge BY: State Fire Protection Inc. 3) Remote manwil pull station to 'be on path of egress 48" max. PO Box 5354 Largo,.FL 33779 727-797-2864 4) � denotes discharge nozzle Stag #02823400031967 5)17'-") denotes fuse link housing 6). Class "K" M rated fire extinguisher to be in kitchen . ( 7) system utilizes 9 of • '8 available flow points iYt I I ATJ&, 5•1 r�!{ 3e � U prcc on-j�A.uc.2 c.�t j?Y C-r'P�CFfiI-�-fl Pp 9� ©t�F eta . kt PA t 7 a 40 13 e.0. J'��r .r PYRO-cHEM® KITCHEN Pm,71yr0KITCHEN KNIGHT®II 'I PCL-16013001460i600 KNIGHT® II U Chem -NOZZLE COVERAGE SUMMARY SHEET. ' Width. Length or Min. Max. Nozzle. Flow in. (cm) Area sq in Height Height Appliance Type Points Max.Side (cm2) in. (cm) in. (cm) Deep Fat Fryer-Vat 2H - 2 191/2 19 in. 24 (61). 48 .(122) Deep Fat Fryer(Low Proximity)-Vat 2L (49.5) (48 cm) 13. (33) 24 (61) Deep Fat Fryer-Drip Pan-(Vat 18 in.x 18 in.max.(45.7 cm x 45.7 cm)) 2H 2 27 3/4 500 24 (61) 48 (122) Deep Fat Fryer(Low Proximity)-Drip Pan (Vat 18 in.x 18 in. mai(45.7 cm x 45.7 cm)) 2L (70.5) (3225.8) 13. (33) 24 .(61) Deep Fat Fryer-Drip Pan.(Vat 191/2 in.x 19 in.max.(49.5 cm x 48.3 cm)) 2H 2 25 3/8 495 24 (61) 48 (122) Deep Fat Fryer(Low Proximity)-Drip Pan(Vat 191/2 in.x 19 in.max(49.5 cm x 48.3 cm)) 2L (64.5) (3193.5) 13 (33) 24 (61) Two Burner Range ,1 H - 1 12 28 in. 40 (102) 50 (127) Two Bumer Range(Low Proximity) 1L (30.5) (71 cm) 13 (33) 24 (61) Two Burner-Back Shelf(High Proximity) 2L 2 28 (71) 336 (2167.7) 24 (61) 35 (89) Four Burney r g ;2" 2 28 (71) 28 in.(71 cm) 34 (86) 48 (122) Small Wok 1H 1 24 in.dia. 6 in.depth 24 (61) 48 (122) Small Wok(Law Proximity) 1 L (61 cm) (15.2 cm) 13 (33) 24 (61) Large Wok 2H 2 30 in.dia. 8 in.depth 24 (61) 48 (122) Large Wok(Low Proximity) 2L (76.2 cm)- (20.3 cm) 13 (33) 24 (61) Sma t Griddle d 1 36 1080 24 (61) 48. (122) Small Griddle(Low Proximity) 1L (91.4) (6968) 10 (25) 24 (61) Large Griddle 2H 2 48 1440 24 (61) 48 . (122) Large Griddle(Low Proximity) 2L (122) (9290) 10 (25) 24 (61) Gas Radiant Char-Broiler 1H 1 26 624 24 (61) 48 (122) Gas Radiant Char-Broiler(Low Proximity) 1L .(66) ' (4025.8) 13 (33) 24 (61) Large Gas Radiant Char-Broiler 2H 2 36 864 36 (91) 48.- (122) Large Gas Radiant Char-Broiler(Low Proximity) 2L (91.4) (5574) - 13 (33) 36 (91) Lava Rock Char-Broiler 2L 2 26 (66) 624 (4025.8) 15 (38) 35 (89) Natural,Charcoal Char-Broiler(max.fuel depth 6 in.(15 cm)) 1H 1 24. 480 24 (61) - 35 (89) Natural Charcoal Char-Broiler(Low Proximity) 1L (61) (3096.8) 15 .(38) 24 (61) .Mesquite Char-Broiler(max.fuel depth 6 in.(15 cm)) 1H 1 24 480 24 (61) 35 (89) Mesquite Char-Broiler(Low Proximity) 1L (61) (3096.8) 15 (38) 24 (61) Upright/Salamander Broiler 1 L 1 36 in.width 28 in.dia. Front edge; (91.5 cm) (71 cm). above the grate Chain Broiler(Internal.Chamber) 1L 1 27 in.width 38 in.dia. Front edge;1-3 in. - (68.5 cm) (96.5 cm) (2.5-7.5 cm)above chain Tilt Skillet/Braising Pan Coverage limitations are based on fryer sizes including the drip boards. Exception:Tilt Skillets and Braising Pans may exceed maximum of 6-ft?(0.56 m2) Nozzle Flow Width Length Nozzle Placement(See Type Points It (m) ft (m) manual for more detail) Single 6anW'BanV 7H_, 1 4 (1.2) 10 . (3) 0-6 in:(0-15.25 cm) - J from end of plenum ' Nozzle Flow Max.Side Perimeter .Diameter Length J ',Duct_? Type Points in. (cm) in. (cm) in. (cm) . eR ante/Circura�; 2g 2 34 (86) 100 (254) 317/8 (81) Unlimited- Rectangle/Circular (2)21) 4 51 (129.5) 150 (381) 471/2(121) Unlimited Rectangle/Circular 1L* 1 163/4(42.5) 50 (121) 16 (41) Unlimited PC2001189(6) PYRO-CHEM® � r®� S KITCHEN KNIGHT@ 11- KITCHEN y PIPE VOLUMES KNIGBt l ChP.I�I CONVERSION CHART ► 1/4 in.=20.5 ml per ft 3/8 in.=37.5 ml per ft - 112 in.=59.8 ml per ft 3/4 in.=.105 ml per ft, Total 1st Nozzle Total Pipe Maximum Pipe Length From 1st Nozzle to Last Nozzle Maximum Pipe.Length 3/8 in. 1/2 in. 3/4 in. 1/4 in.. 3/6 in. 1/2 in. 3/4 in. Cylinder Flow Pipe to Last 114 in. - Size Pis Vol Nozzle ft (m) ft (m) it (m) ft (m) ft (m) ft (m) ft (m) ft (m) PCL 160 5 1500 600 73.1 (22.3)- 40.0 (12.2) 25.0 (7.6) - 29.2 (8.9) 16.0 (4.9) 10.0 (3) - tPCL�300'''':F10 1910 1125 ` 93.2 (28.4) 50.9 (15.5) 31.9 (9.7) 18.2 (5.5) 54.9 (16.7) 30.0 (9.1) 18.8 (5.7): 10.7 -(3.4) PCL 460 14 3400 . 3000 165.9 (50.6) 90.7 (27.6) 56.9 (17.3) 32.4 (9.9) 146.3"(44.6) 80.0 (24.4) 50.2 (15.3) 28.6 (8.7) PCL460 15 2600 2000 126.8 (38.7) "69.3 (21.1) 43.5 (13.3) 24.8 _(7.6) 97.6 .(29.7) 53.3 .(16.3) 33.4 (10.2). 19.1 (5.8) PCL 600 19 4215 1688/side 205.6 (62.7) 112.4 (34.25) 70.5 (21.5). 40.1 (12.2) 82.3 (25.1) 45.0 .(13.7) 28.2 (8:6) 16.1 (4.9) PCL600 20- M65 1312.5/side 169.0 (51.5) 92.4 (28.1) 57.9 (17.6) 33.0_ (10) 64.0 (19.5) 35.0 (10.7)- 22.0 (6.7) 12.5 (3.8) Pipe Length Volume of Agent per Pipe Length/Size Minimum Pipe Volumes for a Fryer,Range,and Wok It (m) 1/4 in- 3/8 in. 1/2 in. 3/4-in. Cylinder Size Entire System At or before appliance . 1 0.30 20.5 37.5 _ 59.8 105 PCL 160 239 ml-1 Flow Pt 180 ml-1 Flow Pt 2 0.61 41 75 119.6 210 PCL 300 300 ml-4-Flow Pts 239 ml-2 Flaw Pts 3 0.91 61.5 112.5 179.4 315 PCL 460 660 ml-10 Flow Pts 180 ml=2 Flow Pts 4 _1.22 82 150 239.2 420 1 PCL 000, 960 ml-14 Flow Pts '120 ml-2 Flow Pts 5 1.52 102.5 187.5 299 525 6 1.83 123 225 358.8 630 7 2.13 143.5 262.5 418.6 735 8 2.44 164 300 478.4 840 9 2.74 184.5 337.5 538.2 945 10 3.05 205 375 598 1050 11 3.35 225.5 412.5 657.8 1155 12 3.66 246 450 717.6 1260 \.. 13 3.96 266.5 487.6 777.4 1365 14 ` 4:27 287 525 837.2 1470 15 4:57 307.5 562.5 897 1575 -:16 4:88 328 600 956.8 1680 17 . 5.18 348.5 .637.5 1016.6 1785 18 5.49 369 675 1076.4 - 1890 19 5.80 389.5 712.5 . 1136.2 1995 ► 20 (6.10) 410 750 - 1196 2100 General Rules: 1. Measurements.taken from fittings centerline(All SCH.40 Pipe). ► % ` 2. Maximum difference in elevation from valve outlet to any nozzle is 10 ft(3.05 m). 3: Largest diameter pipe-must be used first and decrease in size as installation moves away from the tank. '.4.-No traps in the piping. 5. Two elbows are allowed in place of a swivel.Elbows used as a swivel do not have to be subtracted from the total allowed. 6• Maximum of 25 elbows. 7. Maximum of 5 elbows between nozzle and preceding tee. 8. Maximum flows for 1/4 in.pipe=6 flows. 9. Maximum volume allowed for 1/4 in.pipe from tee to nozzle is 410 ml(20 ft or 6.10 m). Additional rules for PCL 600: 1..Split piping must be used with a maximum of 14 flows on a side. 2. No nozzles before the split. 3. Minimum 1/2 in.pipe must be used to the first split.