Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19-21947
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21947 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:21947 Issued: 11/19/2019 Address: 7142 SILVERADO RANCH BLVD Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est.Value: Book: Page: Cost: 355,185.45 Total Fees: 15,565.19 Subdivision: SILVERADO Amount Paid: 15,565.19 Date Paid: 11/19/2019 Parcel Number: 05-26-21-0100-00700-0260 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TAMPA, FL 33637 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 3,153 SQ FT APPLICATION FEES PLUMBING FEE 273.00 ELECTRICAL FEE 409.50 MECHANICAL FEE 191.10 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,931.40 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 NG I� - asp - �A ��- 17 0� I� Inspections Required FOO ER 2ND ROUGH PLUMB MISG INSULATION EILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. (0 11 /�V� &I f"�* CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY Receipt Date: 04/11/2016 PA& S C h' -. BUILDING CONSTRUCTION SERVICES Receipt Number: 1941470 l IL 8731 Citizens Drive COUNTY FLORIDA Suite 230 OmN SP.Aus.117B)MW PiAcFs. New Port Richey, FL 34654 727-847-8126 ** NOT A PERMIT ** Paid By Check# CC Auth# Cashier ID Workstation Check 1066003 SLEBLANC BCCCP06W Fee Description Amount Paid Impact Fee Residential Solid Waste Single Family 53.64 Total Payments: $53.64 payor Address Phone DR Horton Comments: City of Zephyrhills Solid Waste Parcel ID:05 26 210100 00700 0260 Address:7142 Silverado Ranch Blvd. While you will be paying your bill with Pasco County Building Construction Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. G myreportslreportsl/PASCOPROD/PASCO/CustomerReceipt vlfrpt Print Date: 03/31/2020 Page 1 of 1 CITY OF / / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT# ,5 ,�/ The following additions or corrections shall be ma a before the lob THIS JOB HAS NOT BEEN COMPLETED. will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FO -IN CTION or other material,until the proper inspector has had ample time to approve the installatign. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR Check Number 1004258 CIA"OF ZEPHYRHILLS-PERMITTING Date 11/12/19 5335 8TH STREET DRH Inc. Controlled Disb Stub 1 of 1 2149668 , PO Numb Invoice Number Subav Lot# Lot Address Cost Cde Legal Desc Gross Deductions Amount Paid -------- --------------- ----- ---- ---------------------------- --------- ---------- ------------- ------------- ------------- 391630112PERM 39163 0112 7142 SILVERADO RANCH BOULEVA 77/79 15,565.19 15,565.19 ----------- ----------- ----------- 15,565.19 15,565.19 r D.R. Horton-7142 Silverado Ranch Blvd:3,153 sgft Column SQ. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,820.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,931.40 ELECTRICAL: $ 409.50 PLUMBING: $ 273.00 MECHANICAL: $ 191.10 SUB-TOTAL $ 2,805.00 TOTAL $ 2,805.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,358.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,565.19 INSTR#2019189791 OR BK 1 0002 PG 706 Page 1 of 5 11/05/2019 04:37 PM Rcpt 2106055 Rec:44.00 DS:600.60 IT:0.00 Nikki AlvarezSowles, Esq., Pasco County Clerk&Comptroller This Instrument Was Prepared By And Should Be Returned To: Lee E.Nelson,Esq. Shutts&Bowen LLP 4301 W.Boy Scout Blvd.,Suite 300 Tampa,Florida 33607 Tax Identification Nos.: 05-26-21-0100-00700-0250 and 05-26-21-0100-00700-0260 SPECIAL WARRANTY DEED This Special Warranty Deed(this "Deed"), executed as of the '' day of AW641V 2019, by DUNE FL LAND I SUB LLC, a Delaware limited liability company ("Grantor"), whose mailing address is 2502 N. Rocky Point Drive, Suite 1050,Tampa,Florida 33607, to D.R. HORTON, INC., a Delaware corporation ("Grantee"), whose mailing address is 12602 Telecom Drive,Tampa,Florida 33637. WITNESSETH: That Grantor, for and in consideration of the sum of ten dollars ($10.00) and other good and valuable consideration to Grantor in hand paid by Grantee, the receipt and sufficiency of which is hereby acknowledged, has granted, bargained, and sold to Grantee and Grantee's successors and assigns forever, the real property situate, lying, and being in Pasco County, Florida, and described in EXHIBIT A attached hereto and made a part hereof(the"Property"). TOGETHER with all of the Grantor's rights, title and interest in and to all licenses, approvals,tenements,hereditaments, and appurtenances belonging or in any way appertaining to the Property. TO HAVE AND TO HOLD the same in fee simple forever. And Grantor hereby specially covenants with Grantee that Grantor is lawfully seized of the Property in fee simple, and hereby specially warrants the title to the Property and will defend the same against the lawful claims of all persons claiming by, through or under Grantor, but not otherwise, and that the Property is being conveyed to Grantee subject to those permitted exceptions identified in EXHIBIT B attached hereto and made a part hereof, provided the foregoing shall not serve to reimpose the same. [SIGNATURE ON NEXT PAGE] City Of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received ,r l� 'l � J Phone Contact for Permitting. Owner's Name Owner Phone Number ♦ � fJ Owner's Address � �� !� G" i "' p=` ��r n f�1 .` �520w" ner Phone Number Fee Simple Titleholder.Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS Sf d0 rJ LOT# 3UBpiVtStON _(" C� PARCEL ID# A' -0 (OBTAINED FROM PROPERTY TAX NOTICE) ' dVORK PROPOSED NEW CONSTR F7 ADD/ALT SIGN 0 DEMOLISH 'INSTALL REPAIR 3ROPOSED USE SFR [ COMM OTHER TYPE OF CONSTRUCTION . �-� BLOCK FRAME STEEL u )ESCRIPTIONOFWORK efI ���/ l � �`'Srvm� �. b 3UiLDiNG SIZE SO FOOTAGE HEIGHT ti--r-r-r-i-r-a"R'-r-a-s-t�r-r-r'w"r-1 I I a^r"t-r'it-n-re-rrw-r r-ra-m-m�r�"i-'-r'r�rrm�o-il-r�-Q'�"r�->ro"rsrv'II- OBUiLDING $ 5 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $, p i AMP SERVICE 0 PROGRESS ENERGY 0 . W.R.E.C. =PLUMBING $ =MECHANICAL ``$ b I QC) J VALUATION OF MECHANICAL INSTALLATION =GAS d ROOFING SPECIALTY OTHER INISHED FLOOR ELEVATIONS FTI3.,5-b— FLOOD ZONE AREA =YES NO --I-��--1-!F-+ 1-1--1-1-:-,3-P-1••. . . isles-1-�-=�^�'1-��-1--�--1-➢-.5-. 3UiLDER r �-yea,! __. COMPANY a -�0A-A_ej""`_ a- ),c >IGNATURE REGISTERED Y/ N FEE CURREN Y J N Address v� /��cco.r+'7 e- License# cLECTRiC1Ajd f � .-,i .� COMPANY -�- I G % ,IGNATURE REGISTERED Y/ N FEE CURREK Y J N Address License# F_c c ' 'LUMBER a'.� COMPANY i1GNATURE _ - r� REGISTERED Y J N FEE CURREN Y/N Address '� r�r m�� w �s �a', Jam= License# {a re 0 t1ECHANiCAL i. Af �,� P �- � -. COMPANY fff < < a ,IGNATURE "tom'" - REGISTERED Y�f/ N FEE CURREN Y/N Address "��� ,'.. License# 9t,r )THER COMPANY ;IGNATURE ~T� REGISTERED Y/ N FEE CURREN Y/N Address s' wz( License# ➢ ➢ ll" i / 111' i ➢ ➢ iiili � ➢ iIiiIiIIii1111111 'Iillil111NIIIi ,llllllili ➢ 1111 ➢ 11 IESIDENTIAL Attach(2)Plot Pla; (2)sets of Building Plans-, (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten (10)v..irking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit•Fence installed, Sanitary Facilities F i dumpster;Site Work•Permit for subdivisions/large projects :OMMERCIAL Attach(2)Complet( Sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W"Permit for new construction. Minimum ten (10)%-)rking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities,,, 1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance ;IGN PERMIT Attach(2)sets of F 7gineered Plans. *"**PROPERTY'SI!,gVEY required for all NEW construction, - I-1-•I i..1-.A.,-'•al-4.-i-S..6-.1--1.-IQI--B-tI.-F-8-1-»i-1--1-$--1--1- '-1.-1-0�4-➢. ..1--6.. -➢- ..$-B..L B�6�- -➢®➢. 13d.�0-!~. lirections: Fill out application completely. Owner�Contractor sign back of ;)plication,notarized if over$2500,a Notice of Comn ,!ncement is required. (A(C upgrades over$7500) Agent(for the,contractor)or Pam- of Attorney(for the owner)would be someone with notarized letter from owned authofizir��same y4 �r :'r y 1VER THE COUNTER PERMITTING (copy of contract required) eroofs•if shingles g Sewers service Upgrades A/C Fences (Plot/Survey/Footage) �I -• ,�•�•:'-:� _;: �'� ,•_ .� �. i'E •. i:i art•`�;:,pp Driveways-Not over Counter if ots public roadways..heeds ROW . . NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions". which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed-restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contnactorstoundertakevvorh. theymaybaraquiradtobe |iceneedinaucordanoavvithatateand |omdnogu|otione. |fthe contractor is not-licensed as required by |aw, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended-contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or oontraoto,o, he is advised to have the contractor(s) sign portions of the "contractor B|ooK' of this application for which they will be responsible. If you, aa the owner sign as the contractor, that may be an indication that hB is not properly licensed and is not entitled tu permitting privileges.in Pasco County. � TB��y�SP��RT/�[1��MIQ8P/�CT/UTlL0FIESiK8P/�CT AND RE���UR{�EBECOVEFYFEES: The undersigned.understands that Transportation Impact Fees and Recourse Recovery Fees may apply tothe construction of new buUdinga, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 8Q'O7 and 90'07. as amended. The undersigned also understanda�, that such fees, as may be due, will be identified at the time of permitting. it is further understood that Transportation Impact Fees and Resource Recovery Fees.must be paid prior to receiving a ''oerb�rataof occupancy" or�na| power release. {f the project does not involve aoa�|�oeteof occupancy or final power re|o�oa` the fees must be paid prior to permit issuance. Furthermore. if Pasco.County Water/Sewer Impact fees are due,thmyrnuatba paid prior hoerrn�issuance in accordance Vv�happUcab\e Pasco County O[dNancaG. C�<�0STBU��TUC)0 LIEN LAW (Chapter 718, Florida Statutes, as amended): If valuation of Work is$2'500.00 or more, ! certify that |, the applicant, `ave been provided with n copy of the "Florida Construution' Lien Law —Honueuvvner'o Protection Guide" prepared by the Florida Department ofAgriou|ture.and Consumer Affairs. If the applicant is someone otherthanthe "ovvner". | parhfythat | haveobtaineducopynftheabovedescr|boddocunnert and promise |n good faith to deliver|tto the"ovvna/' prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws-regulating construction, zoning and, land development. Application is hereby made to obtain a permit to do,vvork and installation as indicated. ) certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all \owa regulating onnotnuction. County and Chxcodes, zoning regulations, and land development regulations in the jurisdiction. \ also ce��v that | understand that ' n regulations of'othor government agencies may apply to the intended work, and that it is my responsibility ponoibi|itytoidentifv vvha1actions | must take tobeincompUanco. Such agencies include but are not Urn�adto: Department of' Environmental Protection-Cypress Bayheads. VVet|and Areas and Environmentally Sensitive Lands,VVater/NantawatarTroo1mont ' Southwest Florida Water Management [}latdot-VVeUs. Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' Department of Health & Rehabilitative Services/Environmental Health Unit'VVaUs, Wastewater Treatment,.. Septic Tanks. ' US-EmvinonrnentalProtec§onAgenoy-Aebestosabetement. ' Federal Aviation Authoh1y-Runvvaya. \ understand that the following restrictions apply to the use offill: ' Use of fill ia not allowed in Flood Zone"V"' unless expressly permitted. - If the fill material is to be used in Flood Zone ''/Y'. it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by aprofeosiona| onQinee'r licensed by the State of Florida. - If the fill material is to be used in Rbod Zone ''N' in connection wit a permitted Uu||U|nQ using otann vvai| construction, I certify that fill��U\ be used only to fill the area within the stem wall. If fill material is to be used in any area. | certify that use of such fill will not adversely affect adjacent . properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |aos than one /1\ acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.. ( understand that e separate permit may be.required for electrical wnrh, p!unnbing, eigne, vvaUn, pools, air uonddioning, gao.,or other installations not specifically,included in the application. A permitiamuedsha|| b000hstruedtobea /icenaetuproceedwith-thevvorkandnotaaauthoritytovio|ate. canoe|. alter' or aei aside any provisions of the technical codes, nor shall issuance ofa permit prevent the Building Official from th' rea�er U e requiring a correction of errors-in plans, construction or violations of any codes. Every permit issued ahab000minvalid unless-the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is.suspended or abandoned for a period,of six (6) months after the time the Work is commenced. An extension may be rnqueated, in vvrit\ng, from the Building Official for a period not to exceed ninety (90) dqys' and will demonstrate ` justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN PAYING TWICE FOR IMPROVEMENTST0Y0UR PROPERTY. IF YOU INTEND TO OBTAIN FlNA0C.INCS CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF FLORIDA JuRxT(r.S. 117.03) OWNER OR AGENT CowTnxcTo ` u o m u d to (or om Subscribed and sworn vz(or affirmed)before mathis vvnv/w Who islare personally known,omuo,has/have produced as identification. as identification. ' lary Public Notary Public Commission ` Commission No. Name of'`~a'x typed,printed or stampedComm ' n Expires My ommissio __ ti s ' D:R.Horton-7142 Silverado Ranch Blvd-3,153 sgft ufflumn Is SO. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $. - VALUATION $ 355,185.45 FEE SHEET $ 1,820.66 ADDRESS $ 30.00 DRIVEWAY $ 45.00 J / BUILDING: $ 1,931.40 ELECTRICAL: $ 409.50 PLUMBING: $ 273.00 MECHANICAL: $ 191.10 SUB-TOTAL $ 2,805.00 TOTAL $ 2,805.00 SEWER: WATER: IRRIGATION: .$ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES -POLICE $ 254.00 FIRE $ 273.00 6% $ 26.35 TOTAL: S• 553.35 SUB-TOTAL $ 3,358.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,565.19 INSTR#2019190406 OR BK10002 PG2425 Page 1 of 1 11/68/2019 03:35 PM RcPt:2106388.Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq., Pasco County Clerk&Comptroller Permit No. Parcel ID No0%-&6-0-\-D%00- 00700-D&60 NOTICE OF COMMENCEMENT State of Florida County of Pasco, THE UNDERSIGNED hereby gives notice that improvement Wit be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following Information is provided In this Notice of Commencernerit I Description of Properly: Parcel Identification No. Cj . d R a Z V w k\ 5StreetAddresi: 3 q I Z General Description of Improvement New Single FamUy Residence 3. Owner Information or Lessee Information if the Lessee contracted for the Improvement: D.R. Horton. InQ Name 19RQ2 Tgalp-r--naii Drivp TArnpa 33637 El Address CRY State Interest in Property: Fee Simple Name of Fee Simple Titleholder. (if different from Owner listed above) Address city state 4. contractor D.R. Horton. Inc Nam e 12602 Telecom Drive Tampa 33M FL Address city state Contractors Telephone No.: 5. Surety: N/A Name Address City state Amount ofBorst: $ NIA Telephone No.: S. Lender. N/A Name Address City State Lendeei Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: -David Gulle Name 12602 Telacom Drive Tampa S3637 FL Address city -state Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Omer. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording urdess,a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA.STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing n commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signa ure of Owner or Lessee,or Owners or LesseWs Authorized OffloodDirector/Pener/Manager Assistant Secretary/D.R. Horton. Inc Signatory's 71fle/Office The foregoing instrument was acknowledged before me thi�� U day of 2 10%by mboC 0-3 as-Assistant$ecretary ,(type of authority,e.g.,officer,trustee,attorney In fact)for D.R. Hoftn. Inc Loarne of party an behalf o1whorn inst qnt was executed). Personally Known W OR Produced Identification Ej Notary Signature Type of Identification Produced Name(Print) DANA ANNE NAGIRTM State of flor Notary Public-State Of flOr'da 'a 01 06r Commission#GG 010660 com 5 4ul 12 2 My Comm.Expires Jul 12,2020 OF 1, W wpdateibcs/noUescommencemenLpe083048 OR BK 1 0002 PG 707 Page 2 of 5 IN WITNESS WHEREOF,Grantor has executed this Deed on the date first above written. GRANTOR: DUNE FL LAND I SUB LLC, a Delaware limited liability company 4, T By. Signature ofiVitness 1 John M.Ryan,Manager Print name of Witness 1 Si ature o itne 2 Prin nanie of Witness 2 STATE OF FLORIDA ) SS.. COUNTY OF HILLSBOROUGH ) The foregoing instrument was acknowledged before me this -/ day of 019, by John M. Ryan, as Manager of DUNE FL LAND I SUB L C, a Delaware limited liability company, on behalf of the limited liability company, ho is .,personally known to me or(_)who produced "--widentification. [Affix Notary Seal] h�� No Pub 'c (Print or a name) .• Y ., KELLEYREMMEL � :Af, MY COMMISSION#GG 073177 COmm1SSlOri No.: ;= EXPIRES:May 31,2021 My Commission Expires: Bonded 7hin Nolery Public Undem9en; OR BK 10002 PG 708 Page 3 of 5 EXHIBIT B Permitted Exceptions 1. Taxes and assessments for the year 2020 and subsequent years,which are not yet due and payable. 2. Restrictions, dedications, conditions,reservations, easements and other matters shown on the plat of SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A,AND 11B, as recorded in Plat Book 77, Page(s) 79 through 86, inclusive, of the Public Records of Pasco County, Florida,including Surveyor's Note 7 as recited in 12 below. 3. Notice of Establishment of the Silverado Community Development District recorded in Official Records Book 9135, Page 1403; Ordinance No. 1241-14 recorded in Official Records Book 9123, Page 3 and re-recorded in Official Records Book 9179, Page 3371 and re-recorded in Official Records Book 9399,Page 2667,all of the Public Records of Pasco County,Florida. 4. Ordinance No. 1247-15 recorded in Official Records Book 9170, Page 87, amended by Ordinance No. 1326-17 recorded in Official Records Book 9551, Page 45, both of the Public Records of Pasco County, Florida. 5. Terms and conditions of the Declaration of Consent to Jurisdiction of the Silverado Community Development District, Imposition of Special Assessments, and Imposition of Lien of Record recorded in Official Records Book 9388, Page 227, of the Public Records of Pasco County,Florida. 6. Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and Maintenance of Improvements of the Silverado Community Development District (Series 2016A-1 Bonds) recorded in Official Records Book 9388, Page 241, of the Public Records of Pasco County,Florida. 7. Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and Maintenance of Improvements of the Silverado Community Development District (Series 2016A-2 Bonds) recorded in Official Records Book 9388, Page 246, of the Public Records of Pasco County,Florida. 8. Declaration of Covenants, Conditions and Restrictions, including any amendments or modifications thereto,recorded in Official Records Book 9443,Page 1105, of the Public Records of Pasco County,Florida. 9. Declaration of Consent to Jurisdiction of the Silverado Community Development District, Imposition of Special Assessments, and Imposition of Lien of Record as recorded in Book 9598,Page 3122, of the Public Records of Pasco County,Florida. 10.Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and Maintenance of Improvements of the Silverado Community Development District (Series 2017A-1 Bonds) recorded in Official Records Book 9598, Page 3180, of the Public Records of Pasco County,Florida. OR BK 1 0002 PG 709 Page 4 of 5 11.Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and Maintenance of Improvements of the Silverado Community Development District (Series 2017A-2 Bonds) recorded in Official Records Book 9598, Page 3185, of the Public Records of Pasco County,Florida. 12. Private drainage easements shall not contain, except for the construction and maintenance of nature trails and walks by the developer, permanent improvements, including,but not limited to sidewalks, driveways, impervious surfaces, patios, decks pools, air conditioners, structures, utility sheds, and sprinkler systems. The installation of poles, fences, trees, shrubs,hedges, and landscaping plants are permitted if installed in a manner that will not obstruct the free flow of water and prohibit access to those easements labeled access easements. However, it will be the individual lot owner's responsibility to bear the full cost of said poles, fences, trees, installation, repair, and maintenance of surface/subsurface drainage structures and grading according to the approved grading and drainage plan. TPADOCS 22807525 128053.0168 OR BK 1 0002 PG 710 Page 5 of 5 EXHIBIT A Legal Description Lots 25 and 26,Block 7,of SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A,AND I IB, according to the Plat thereof, as recorded in Plat Book 77,Pages 79 through 86,inclusive, of the Public Records of Pasco County,Florida. 05-26921-0100-00700-0260 I Pasco County Property Appraiser Page 1 of 1 Parcel ID 05-26-21-0100-00700-0260 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $24,121 2502 N ROCKY POINT DR STE 1050 Building $0 ROCKY POINT, FL 33607-5995 Extra Features $0 Physical Address Just Value $24,121 7142 SILVERADO RANCH BOULEVARD, ZEPHYRHILLS, FL 33541 Assessed (Non-School Amendment 1) $2,770 Legal Description (First 200 characters) Non-School Taxable Value $2,770 School District Taxable Value $24,121 See Plat for this Subdivision Warning: A significant taxable value increase may occur when sold. SILVERADO RANCH SUBDIVISION Click here for details and info. regarding the posting of PHASES 7, 9B, 11A AND 11B PB 77 exemptions. PG 079 BLOCK 7 LOT 26 OR 9535 PG 0546 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) _ Line Use Code Description Zoning Units —Type Price jConditionjValue 1 0100V LP1-1 SFR MPUD 6,000.00 _ SF $4.00 1.00 $24,000 2 0100V LP1-2 SFR MPUD 303.00 SF ' $0.40 1.00 $121 Additional Land Information _ Acres Tax Area FEMA Code Res Code Com Code Condo Code_ 0.14 30SI I -- SLVR SLVR SLVR Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) Line LC a (Description — Year Units ^ _ jValue No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type _ DOR Code ;Condition Amount 05/2017 19535 / 0546 Certificate of Title 05 j Vacant $0 11/2016 _ 9462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant $0 04/2016 19364 / 0688 Mineral Rights or Royalty Transfer 05 Vacant $0 03/2016 9356 / 1231 Mineral Rights or Royalty Transfer_ 05 Vacant I $0 09/2011 18606 / 3376 I Warranty Deed 1 05 Vacant 1 $0 http://search.pascopa.com/parcel.aspx?parcel=2126050100007000260 10/21/2019 D . . Single Family-Dwelling Plan Review Comments 1. F.F.E.. shall.be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with.R401.3 of the F.B.C. 3: Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6: All setbacks-shall be met. 7. All property markers shall be uncovered.and marked at time of first inspection.. 8: All A.D.A.-requirements shall be met: 9.. No electric,.plumbing;mechanical,or framing shall,be' covered without an inspection and approval first. 10. All Garages shall comply with section R302'.6 of the F.B.C. (Fire Separation). 1.1. Appliances shall not be installed in a'location where e-subjectj6 mechanical damage unless protected by approved barriers. M303A of the F.B.0 12. water heaters shall comply with section P607.3 of the F.B.C: 13. Foundation supports for AX-units shall be raised at least 3" above finished grade. M1308:1 14. Return air iri all bedrooms'. F.B.C. M1620.4 15. Smoke:detectors are to be installed_ in accordance with R313:1 of the F.B.C. 16:All glazing requirements are to be in accordance:with R308.4 of the F:B.C: - 17. All means.of egress are to be in accordance with R311 of the F.B.C. . 18. "Green.gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 10. Combination-type AM breakers are required at all locations requiring an AM type breaker. -20. Carbon monokide alarms will be required in-new construction that-uses fossil-burning heating or appliances or an attached garage. They shall be:installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground:plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced: 21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 NX.0 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure. 2& R403.5UHot water pipe insulation Insulation for hot water. pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping 3/. inch (19.1 mm)and larger in.nominal diameter. Piping,serving more than_one dwelling unit. Piping located outside the conditioned space:_ Piping from the water heater to a distribution manifold.. Piping located under.a floor slab. Buried in piping, Supply and return piping in recirculation'systems other than demand recirculation systems. 25.Blower-door test shall be provided before C.O. 26. A copy of the ener y cacls shall be with permit at all times 27 Copy of final insulation report-shall-be provided with permit before fnaL 28 No fence, pool or screen enclosure Is issued•with ihis permit. F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 6`h Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) f FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 El K t Builder Name: DRH Express Homes Street:-:TN 2-Z Permit Office: CV City,State,Zip: Zephyrhills, FL, 33. [N n "J Permit Number: 2� `� 7 Owner: Jurisdiction: / /6�00 n (A Design Location: FL,Tampa ( ( _/ County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2389.10 ftz b.Frame-Wood,Adjacent R=11.0 314.89 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 5 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types (1541.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ftz 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(251.7 sgft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 211.67 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.948 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sgft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features b.Raised Floor R=19.0 437.00 ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.097 Total Proposed Modified Loads: 84.92 PASS Total Baseline Loads: 86.07 1 hereby certify that the plans and specifications covered by Review of the plans and O�tE SxgrF this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 2-24-14 this building will be inspected for c�7 T 1V1j1 compliance with Section 553.908 * �' I hereby certify that this building, as designed,is in compliance Florida Statutes. with the Florida Energy Code COD OWNER/AGENT: BUILDICJAh DATE: DATE: LL - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. 8/26/2019 9:39 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 26_095,`El K Builder Name: DRH Express Homes �Z Street:-; - 5I I er6 *V.W Permit Office: City,State,Zip: Zephyrhills,FL, Z3�N 11 "J Permit Number: Owner: / 2 Jurisdiction: Design Location: FL,Tampa �� "/ County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2389.10 ft2 b. Frame-Wood,Adjacent R=11.0 314.89 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(251.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 211.67 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.948 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.097 /1�7�7 Total Proposed Modified Loads: 84.92 PASS SS Total Baseline Loads: 86.07 I hereby certify that the plans and specifications covered by Review of the plans and 'Y E 5 A this calculation are in compliance with the Florida Energy specifications covered by this `vQ, ©�, Code. calculation indicates compliance �,,,�'' ;:;; rs+ with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed,is in compliance Florida Statutes. with the Florida Energy Cod fob WE11.� OWNER/AGENT: ////// BUILD, OF�C DATE: DATE, - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. 8/26/2019 9:39 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Hayden 2605 Elev K Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 2605 Lot# 26/7 Owner Name: Total Stories: 2 Block/Subdivision: Silverado #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage R Face W CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 2605 22630.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1501 13058.7 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ftz ---- 0.2 0 0.8 2 Raised Floor 2nd Floor ---- ---_ 437 ftz 19 0.5 0 0.5 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1669 ftz 0 ft2 Dark Y 0.92 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1541 ftz Y N 8/26/2019 9:39 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>W Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0 2 W=>S Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0 3 S=>E Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0.6 0 4 E=>N Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0 5 N=>W Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0 6 W=>S Garage Frame-Wood Main 11 16 0 8 8 138.7 ft2 0.23 0.01 0 7 N=>W Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 8 W=>S Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 9 S=>E Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 10 E=>N Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated Main None .4 3 6 8 20 ft2 2 N=>W Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 6 ft 0 in 0 ft 2 in None None 2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 6 ft 0 in Oft 1 in None None 3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 46.5 ft2 1 ft 0 in 10 ft 11 in None None 4 S=>E 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 5 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 2 ft 0 in 0 ft 6 in None None 6 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 N 8.7 ft2 1 ft 0 in Oft-11 in None None 7 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 N 30.0 ft2 1 ft 0 in 2 ft 9 in None None 8 S=>E 9 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 1 ft 0 in Oft 11 in, None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0 8/26/2019 9:39 AM EnergyGauge@ USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 2640.2 144.94 272.59 .193 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 41 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 261 ftz 2nd Floor 45 ft2 Proposed Qn 2nd Floor ---cfm 156.3 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolingr Jan r Feb [r�]1 Mar r Apr r Ma rX�Jun [X�Jul X]AugX�Se Oct Nov Dec Heatin [ Jan [ Feb l�J Mar Apr r May [ ]Jun l ]Jul 4 J Auf ]Sep E Oct Nov Dec Venting [ Jan [ Feb [X]Mar Apr [ May [ ]Jun L[ ]Jul [ J Aug [ ]Se lXl Oct Nov Dec 8/26/2019 9:39 AM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 Main Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 2nd Floor 8/26/2019 9:39 AM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location 2nd Floor 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 5 13.Cooling system: Capacity 40.0 a) Split system SEER 5. Is this a worst case?(yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2605 d) Room unit/PTAC EER e)Other 14.0 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.373 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.315 14. Heating system: Capacity 41.0 c)Area 7c. 251.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8.Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f)Other 8.20 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 19.0 15.Water heating system c) Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired,natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(Insulation R-value) 10B1. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. Yes e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded) in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: Si��[�GI[ c�ZC)'1C�1 �/�City/FL Zip: Zephyrhills, FL ?, 3 8/26/2019 9:39:30 AM EnergyGaugeO USA 6.0.03(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL ❑ R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal enveloy5he building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at anytime after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 8/26/2019 9:39 AM EnergyGauge@ USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. ❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(131C)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 8/26/2019 9:39 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). Fi R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. ❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916 8/26/2019 9:39 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at ❑ the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 8/26/2019 9:39 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatory)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 8/26/2019 9:39 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605 Elev K Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Y U Owner: Jurisdiction: w Design Location: FL,Tampa U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids Wes and walls or rpil a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 8/26/2019 9:39 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower. Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Job I'nformatid'li Builder: DRH Express Homes Community: Lot: 26/7 Address: City: Zephyrhills State: FL Zip: Alr: L@akage Test<ReSUItS Passing results must meet either the Performance, Prescriptive; or ERl Method, O PRESCRIPTIVE METHOD=The building or dwelling:unit sfiall"be tested and verifie6as having-an air.leakage rate of:not exceeding:7 air changes per hour At,a pressure"of 0:2 inch w:g.(50 Pascals)in Climate Zones 1.arid 2:, :0. . PERFORMANCE"or.ERI METHOD-The."building'or dwelling unit shall be'-tested arid�Verified as having an air leakage'rate.of not,exceeding. the selected ACH(50)value;.as-shown on:Form R405=2017'(Pecforrriance)or R406-2017(ERI),.section labeled as.infiltration,,sub-section ACH50: ACH(50):specified on Form R405-2017 Energy Calc"(Performance)br-R406-2017(ERI): f 7.000 x 60 _ 22630 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans PASS •Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 8/26/2019 9:39:50 AM EnergyGaugeO USA 6.0.03(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Job Information Builder: DRH Express Homes Community: Lot: 26/7 Address: City: Zephyrhills State: FL Zip: Duct Leakage Test Result s O, Prescriptive:Method �, Per:.formance/ERI Method System 1 cfm25 0-Prescriptive Method cfm25"Total System 2 cfm25 To=qualify:as.`'substantially.leak free"On Total-must be less Phan or...:.: equa[to 0:04 if,airhandler,unit is installed. If air handler unit is not System 3 cfm25 installed,.`Qn.Total must be less than or,* ual to O' 3. This testid method"rneets,the requireinents.in.accordance with Section R403 3.3'... Sum of any cfm25 Is the.air,Handler unit installed during.tosting? 1]8ES (So°) D NO(SQ°3j Total of all cfm25 Q Performance/ERI Method cfm25".(0ut.or Total);:' To qualify using this method, Qn.must.not be greater than the_ . 2605 = Qn proposed duct leakage Qnapecified on'Form R405=2017 or Iq 6 2017; Total of all Total Conditioned systems square Footage Leakage Type selected on Form, Qii specified-on Forrri R405-2017 R405-20 17,(EnergyCalc)or R40-6-20i7 ,(EnergyCalc)or R406-201-7 PASS FAIL Proposed Qn 0.06 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or(i), Florida Statutes. Testing Company Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above,either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 8/26/2019 9:39:56 AM EnergyGauge@ USA 6.0.03(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Wrightsoft® Manual S Compliance Report Da Entire House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton Lot 26 Blk 7 Silverado, Zephyrhills, FL Cooling • • Design Conditions Outdoor design DB: 91.2°F Sensible gain: 31195 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1 OF Latent gain: 4122 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 35317 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32444 Btuh 1040%of load Latent capacity: 6297 Btuh 153%of load Total capacity: 38741 Btuh 110%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 40.0°F Heat loss: 27188 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042+FB4CNP042 Actual airflow: 1367 cfm Output capacity: 37285 Btuh 1370%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF Meets are all requirements of ACCA Manual S. I'1 IltSOft, 2019-Aug-26 09:40:05 W 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCK ..press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: W ® Load Short F Job: -�- Wrightsoft ortorm Date: Entire House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 3466E Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton Lot 26 Blk 7 Silverado, Zephyrhills, FL Design Information Htg Clg Infiltration Outside db(OF) 40 91 Method Simplified Inside db (OF) 70 75 Construction quality Semi-tight Design TD (OF) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO42 Cond CH14NBO42 AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 470F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=9 kW, Output=29290 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft.) (Btuh) (Btuh) (cfm) (cfm) living 277 2486 3486 125 153 bed 2 164 2826 1882 142 82 bath 2 59 965 367 49 16 flex 163 2901 3098 146 136 foyer 69 1332 881 67 39 stairs 40 0 0 0 0 bed 4 175 1843 2055 93 90 bed 3 183 2067 3217 104 141 wic 57 144 181 7 8 wic 2 30 767 855 39 37 m suite 287 2737 3956 138 173 m bath 103 330 294 17 13 upstairs living 226 1220 2484 61 109 stairs 2 50 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rh- wri htsoft® 2019-Aug-26 09:40:05 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCX ..press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: W bed 5. 175 1831 2038 92 89 laundry 49 483 932 24 41 a/c 19 0 0 0 0 bath 3v 50 390 278 20 12 hall 62 0 0 0 0 kitchen/dining 325 4460 4914 224 215 bath 3 42 405 275 20 12 we 21 0 0 0 0 Entire House d 2623 27188 31195 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM 31195 Latent cooling 4122 TOTALS 2623 27188 35317 1367 1367 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. htsofta 2019-Aug-26 09:40:05 wri T 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 ACCK ..press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: W Pro Summar Job: wrightsoftm Entire House Y Da By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Proeect Information For: DR Horton Lot 26 Blk 7 Silverado, Zephyrhills, FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20622 Btuh Structure 22264 Btuh Ducts 6566 Btuh Ducts 8931 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 27188. Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 31195 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2659 Btuh Ducts 1463 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2623 1 2623 Equipment latent load 4122 Btuh Volume (ft3) 21860 21860 Air changes/hour 0.22 0.11 Equipment total load 35317 Btuh Equiv.AVF(cfm) 80 40 Req. total capacity at 0.75 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042 Cond CH14NBO42 AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 470F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=9 kW, Output= 29290 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htsoft" 2019-Aug-26 09:40:05 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: W FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance)Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page)and an input summary checklist that can be used for field verification (usually four pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO for the Performance Method. ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 8/26/2019 9:13:21 AM EnergyGaugeO USA 6.0.03(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 I ' I ' PASCO COUNTY, FLORIDA Fbrt_nit No. Z!9 e17 Date PWT11084 1 Bulkier NamelOwner Name �7)/ rN��Zl� Control#• County Parcel No. �rLb-LI-b lop.-GID7ib-b Suboiv: Addrese/locaaon 71 r Classiflcationrtype of Usq 5 f o TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit /T3 i Exempt ❑Yes ❑No How Determined ' 1 ' Impact Fee Amount S 3/ Zone No. TAM SCHOOL IMPACTFEE Account (06% Stngle-Famlly Detached House Amount ��J` (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt b Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Lend Total r Recreation Account -Recreation Credit -Recreation Total Zone TOTAL AMOUNT • I Exempt ❑Yes ❑No How Determined LIBRARY FEE Land Account Land Credit Land Total i Faclllty.Account Facility Credit Facility Total Exempt ❑Yes ❑No How Determined Total Amount I RESOURCEFEE ERU TOTAL AMOUNT Prepared By Chocked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE ..BEEN PAID;AND: RECEIPTED FOR BY ACENTRAL PERMITTING OFFICBOF PASCO COUNTY Admowlodpcment botow does not ImpN acoopwnce of concurrence,but shpb receipt eta copy of tide form,plaelnp the bWWlmp permit owner on notice of dde assessment and tha conditions of payment for game. DATE RECEIVED BY RECEIPT NO, DATE BY N PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 26, BLOCK 7, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 118 AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. a z �Nps 1• = 30' PNS GE 55 GR GRAPHICSCALE \ COCK\�PP PRC 0 15 30 Z��`fR P�j e 133' S69. + 6S3�E cONR� q�r , \ \ �R�91wB�N��c -' �•y�\�' •\ �q�jo"�9�0 `i ��O 47 N 4,�\ \ 29 p SoC)10 o \ 4•o SCOD \ < z w x r v 40. D O 1 Z cw '. 25.0 CIA :�:� 1 N15'`RAp1N•� 1 tit BOCK -7 25 1 \ 1 1 \ 1 ON LOT CALCULATIONS LOT = 6,303 SQ. FT. LIVING AREA = 1.104 SQ. FT. 1 GARAGE = 437 SQ. FT. ENTRY = 111 SQ. FT. LANAI = 0 SO. FT. W Curve Table PATIO = 80 SO. FT. Curve/ Length Radius Delta Chord Bearing Chard DRIVEWAY = 661 SO' FT. A/C PAD = 12 SQ. FT. C1 47.88' 780.00' 330'58' N1S'47'30'W 47.85' WALKWAY = 30 SQ. FT. PI IMPERVIOUS = 39% PREPARED FOR: C2 39.91' 905.00' 23T'3r S15,7'50•E 39.91, = 2435 SQ. FT. *� ��y C3 357.26' 740.00' 273941" N19'40'oe'W 353.80, SOD = 3,868 SQ. FT. U'R•NUMN*� OFF LOT CALCULATIONS 23cta 251.41' 740.00' t9z7'5r N2348'00'w 250.20' RIGHT OF WAY = 1224 SO. FT. C5 105.85' 740.00' 891'4,V ND95WIO*W 105.76' DRIVE APRON - 143 SO. FT. BUILDING SETBACKS PUBLIC S/W = 376 SQ. FT. SOD = 705 SO. FT. FRONT: 22' TOTALS REAR: 15' AREA = 7,527 SQ. FT. SIDE: 5' (50' LOTS) DRIVEWAY = 804. SO. FT. 7.5' (55' dD 60' WIDTH LOTS) SIDEWALK = 406 SO. FT, SIDE STREET: 15' SOD = 4.573 SO. FT. NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING LEGEND: PLANS PROVIDED BY THE CLIENT. 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. � PI POINT OF INTERSECTION —• — — BUILDING SETBACK UNE PC POINT OF CURVATURE 3. FOR ALL LOTS WHERE SIDE—YARD ——— CENTERUNE PT PONT OF TANGENCY SETBACKS ARE LESS THAN 7.50 FEET, A ——— RP RADIUS POINT RIGHT OF WAY LINE POINT OF REVERSE CURVATURE MINIMUM 5.00 FOOT WIDE DRAINAGE AND PRC PO 1OL,X% PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE ACCESS EASEMENT IS REQUIRED PER PASCO TYP TYPICAL COUNTY LAND DEVELOPMENT CODE. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ;:;,z CONCRETE �C PER PLAT ) CALCULATED ONLY. THIS IS NOT'INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PS PAGES PLAT BOOK -OPTION-LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA'FURNISHED BY CLIENT D&AE DRAINAGE&ACCESS EASEMENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM _ THIS IS NOT A SURVEY D&UE DRAINAGE&UTILITY EASEMENTL GEODETIC VERTICAL DATUM THIS IS A PLOT PLAN ONLY POE PUBLIC UTILITY DRAINAGE FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED-TH Ftt -1WAP-N0.12101CO2BBF, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DA70 SEPTEM ER 28,2014.AND FOUNDyTHE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO IN ZONE-X-,AREAS OFrERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2X ANNUAL ChANCE FLOODPLAIN 7HE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS THE-ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE NORTHWESTERLY UNE A!5hR 3. NOT VALID WITHOUT THE AUTHENTIC OF LOT 26, BLOCK 7 BEING N72z7'02-E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E R I C A N SURVEYOR AND MAPPER. (FIELD DATE:) S U FR V E Y I N G Lc¢wwo 1' 30 FEET �`::.::Ya Dm=9gn.anyiame:w.mieman SCALE: 8cM A P P I N G I N C. ''`°°"""°� °DIN:meying&Wppioieman,�amed°a^ . Surveying&Mapping,In4 a=HB, APPROVED BY: '� emmiatoiemanpasmmrpatecom, CERTIFICATION M G RE BOULZATIONEVARD, NUMBER LB/6393 n�11 .1e:26 FOR 180820 LOT 28, 3191 MAOUIRE BOULEVARD, SUITE 200 ••�.+'� Date:zatgmntsszmgaoa THE JOB NO. BLOC(7 ORLANDO. FLORIDA 32803 o FIRM (407) 426-7979 DRAWN BY: D� PLOT PLAN 08-20-19 NO WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE