HomeMy WebLinkAbout19-22116 CITY OF ZEPHYRHILLS
5335 -8TH STREET
(813)780-0020 22116
BUILDING PERMIT /
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 22116 Address: 4718 GALL BLVD
Permit Type: SIGN ZEPHYRHILLS, FL.
Class of Work: WALL SIGN Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 14-26-21-0100-03600-0070
Improv. Cost: 450.00 OWNER INFORMATION
Date Issued: 12/05/2019 Name: CVS 301 PROPERTY LLC
Total Fees: 67.50 Address: 4556 PENSFORD CT
Amount Paid: 67.50 WESLEY CHAPEL, FL 33543-6606
.Date Paid: 12/05/2019 Phone: 201-838-4848
Work Desc: INSTALL NON ILLUMINATED SIGN PANEL
CONTRACTORS APPLICATION FEES
LINER CONSTRUCTION OF FLORIDA SIGN 67.50
t� I
FOOTER Ins ections Re uired
ELECTRICAL ROUGH
FINAL
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRAC OR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
C ity of ZephyrhiIIs
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: Li Gr
C�
Date Received: IL z 1 J1 q 1
Site: q 7/6 6^-(/ t
Permit Type; U'
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments:
6
ef
This comment sheet shall be kept with the permit and/or plans.
Kal ' witz —Pl xaminer D to Contractor and/or omeowner
(Required when comments are present)
~ 813-780.0020 City of Zephyrhills Permit Applic FaX el3aao 0021
Building Department
'
�7 �
Date Received 1, .i ,[� Phone Contact for Permittin 813 715-2333
Owner's Name Y /� a Owner Phone Number d
Owner's Address `T��//� AW-9 AD L Owner Phone Number
Fee Simple Titleholder Name VVG✓� �i� Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 4718 Gall Blvd./Zeph rhills, FL 33542 LOT#
SUBDIVISION PARCEL ID# 14-26-21-0100-03600-0070
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED B NEW CONSTR B ADD/ALT ® SIGN = = DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR ® COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL =
DESCRIPTION OF WORK Install non-illuminated max-metal sign panel to building fascia.
BUILDING SIZE SQ FOOTAGE= HEIGHT
t ® ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ . ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ L-
®BUILDING $450.00 VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C.
=PLUMBING $
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION v
=GAS = ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY Liner Construction of Florida, Inc.
SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/N
Address 124160 SR 54/Unit 1 /Lutz, FL 33559 License#I e,86 Z r&,gaa'�
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRENT
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURRENT
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURRENT LXLN
Address I License#
OTHER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURRENT LYLN
Address License#
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;RAW Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwaler Plans w/Slit Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionsllarge projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonmwaler Plans w/Slit Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Ililtllllllllllllllllllllllllllllllllllllllllllllllllllllllllll
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notadzed
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
•• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
i
' S
v'
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES : If the owner has hired a contractor or
contractors to undertake work,they may be required to be lice nsed in accordance with state and local regulations. If the
contractor is not licensed as required by law,both the ow ner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are un certain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign
portions of the"contra ctor Block"of this application for which they will be responsible. If you,as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES : The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fe as may apply to the construction of new buildings,change of
use in existing buildings,or expansion of existing buildings ,as specified in Pasco County Ordinance number 89-07 and
90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impac t Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore,if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that I,the applicant,have been provided with a copy of the"Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Ag riculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulatin g construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also
certify that I understand that the regula tions of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health&Rehabilit ative Services/Environmental Health Unit-Wells,Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A",it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone"A"in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area,I certify that use of such fill will no t adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the atta Chad permit application,for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understan d that a separate permit may be required for electrical work,
plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included In the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issu ance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or viol ations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested,in writing,from the Building Official fo r a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03) M- / F�
OWNERORAGENT CONTRACTOR C/Y
Subscribed and swam to(or affirmed)before me this Subscribed and swam tg(gby rtmtgd)4aWe th
Who Is/are personally known to me or hasthave produced Who is/ar ersonally known o me or hasihave produced
as identification. as identification.
0______Notary
Notary Public qej&�eg
I Public
Commission No. Commission No. /,Z—o-
,,.,.M; ;-1,- ROBERT MARK WILLETT
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ;.. 1 n#FF 944211
=a; Expires December 16,2019
ilmodTt.TwiFunlna—t;*3957st9
4819 Allen Road-.Zephyr4#ls,'FL 33541
:Sales@Craay4Signs.com Office:813-715-2333 .:
LETTER OF AUTHORIZATION
RE:Just Stop Bargains. .
City of ZephyNils Building Department, .'
I, •Chet Patel of.CVS.301 Property: LLC:- owner of the.pYoperty.located at:4718:Gall.•Blvd. /.
Zephyrhills; FL 33542, do.h.ereby:authoriie:Li'ner.Construction of Florida; Inc:, to obtain a building permit to .
install.•anon-illuminated wall sign at the above listed address.. .,
Lines Construction of Florida, Inc. is.jointly:working•with Crazy4Sign•s, LLC::for:said•property'aignage'(design;
fabrication;&.installation):
Property owner information:
. .Name: Chet Patel CVS-301 Property. LLC:
AddrL-ss:4556 Pensford Ct.'/.Vl/esley Chapel, FL335 43
Phone: 201-838-4848 .
Project Parcel ID#: 14-26 21-0100-03600-0010
Signature: Date:: .
Sw.orn.and subscribed before me this_-ate day of 2419. .
My commission expires: Notary Public
Doti ty a§e, . 'DEB BUYER PATEL
* * Cornm{ssion�GG 165264
E*r"DOCWI r4,2M
OFR� SofWdThNBYdpRtbtry$IMDN
• y
LETTER OF AUTHORIZATION
City of Zephyrhills Building Department,
This letter is to authorize Deborah Patel of Crazy4Signs, LLC.,to submit, pick up, and pay
for permitting on my behalf for the following project ONLY:
Just Stop Bargains-4718 Gall Blvd./Zephyrhills, FL 33542
Scope of Work-Installation of Non-Lighted Wall Sign Panel to Building Fasica
Signature: Date:
Printed Name: >=.cM. -1,J 0►2. Jv_
License#: G 4 G D�o6Z2 5
County: PASCO
State: FLORIDA
Sworn and subscribed before me this day of ' \6tc ej , 2019, by
who is personally known to me or has/have produced
as identification.
-/ li
My commission expires: � !�u 9 Notary P ub
4-AAky""", ROBERT MARK WILLETT
.: u Commission#FF 944211
`+s Expires December 16,2019
°�P,.tk11r Bonhd Rau Troy fin M=wce 8W,18.7019
14-26-21-0100-03600-0070 1 Pasco County Property Appraiser https:Hsearch.pascopa.com/parcel.aspx?parcel=212614010003600007(
Parcel ID 14-26-21-0100-03600-0070 (Card: 1 of 1)
Classification 01100-Stores
Mailing Address Property Value
CVS 301 PROPERTY LLC Ag Land $0
4556 PENSFORD CT Land $55,235
WESLEY CHAPEL, FL 33543-6606 Building $148,191
Extra Features $6,519
Physical Address
4718 GALL BOULEVARD, lust Value $209,945
ZEPHYRHILLS, FL 33542
Assessed (Non-School Amendment 1) $209,945
Iggal Description (First 200
characters)
Non-School Taxable Value $209,945
See Plat for this School District Taxable Value $209,945
Subdivision
ZEPHYRHILLS COLONY COMPANY PB
1 PG 55 WEST 150 FT OF SOUTH
131.08 OF NORTH 281.08 FT OF
TRACT 36 LYING EAST OF EAST R/W
LINE OF US 301 OR 9753 PG 1900
Jurisdiction
CITY OF ZEPHYRHILLS
r Land Detail (Card: 1 of 1)
— -- - - J -p -- -- --9 112,000.00.... !Price
-- -- ion
-_ _ �— -- - --------- �- - - Type . Price Condition Value
Line !Use Code Description Zomn Units �--_SF I _$_3.46 ' 1.00 1 1100_C I 1AT-1 Store 1 Floor OOC2 _ _ 1 $41,520
2 1100C 1AT-2 Store 1 Floor 0OC2 7,662.00 j SF $1.79 1.00 I $13,715
Additional Land Information
Acres i Tax Area FEMA Code Res Code Col Code Condo Code
0.45 30ZC -- M301 M301 M301
View Sketch Building Information - Use 1100-Retail Stores (One Story) (Card: 1 of 1)
Year Built 1949 Stories 1.0
Exterior Wall 1 Concrete or Cinder Block Exterior Wall 2 None
Roof Structure Gable or Hip Roof Cover Min Roof(Corr. or Sh M)
Interior Wall 1 Masonry or Minimum Interior Wall 2. None
Flooring 1 Finished Concrete Flooring 2 None
Fuel Electric Heat Forced Air - Ducted
/C Central Baths 1.0
Line Code 'Description _ ;Sq. Feet, Value
1 SDA01 SERVICE DISPLAY AREA 5,280 $146,581
2 CAN01 CANOPY 192 $1,610
Extra Features (Card: 1 of 1)
Line Code Description jYear IU_ni_ts 'Value
-- ---------
PAVING ASPHALT - 19_85 1,924 _ $_563
2 CPVCFSF ! PVC FENCING (SF) 2016 2,304 $5,956
Sales History
Previous Owner: RDPD IV LLC
Month/Year Book/Page Type DOR Code Condition'Amount,
07/2018 9753 / 1900 Warranty Deed 01 Improved $260,000
12/2015 9298 / 0459 Warranty Deed 01 Improved. $195,000
06/2013 8884 / 2689 Warranty Deed 11 Improved $0
07/2010 '8382 / 0445 Personal Representative's Distributive D 19 Improved $0
01/1980 1050 / 0002 Improved $150,000
Job name Just Stop Bargains
Job# 0919C4S
Sign company: Crazy 4 Signs
Installation location: 4718 Gall Blvd.;Zephyrhills;•FL 33542
Section 1609.6.4 of Florida Building Code 2017 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure: Inon illuminated panel sign 4mm ACM panel)
Occupancy Category: II
Ultimate design wind speed,figure C, FBC 2017, section 1609: 140 mph
Wind stagnation pressure(qz)per 1609.6.3 FBC 2017 50.2 psf
Net Pressure Coeficient(Cnet)from Table 1609.6.2(1)
Components and cladding not in areas of discontinuity-walls and parapets -1.09
Wind Pressure -54.7 psf
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
-maximum height of structure to be attached IA1.00
ft
-maximum width of structure to be attached ft
-fill factor
-projected area of each component to be attached 20.0 ft^2
-wind load -1094 Ibs
-design limit tension load per fastener to 150 Ibs
-even number of fasteners minimum of 2= -8
-number of fasteners practically required due to structure shape 10
-weight of structure is approximately 100 Ibs
-design limit shear load per fastener to 125 Ibs
-average shear load per fastener= 10.0 Ibs
Mounting surface construction is: 1cmu
Use methods: 1l4"tapcons
Method-1/4"x 1 1/4"Tapcon
-depth of embedment in hollow concrete bock= 1 1/4"
-pullout strength=754 Ibs
-shear strength= 1218 Ibs
httos://www.tapcon.com/getattachment/49dc7672-ddfd-4cf5-973d-eO5565349el0/charts performancetables bluewhitestainless v0-1 c.asax
References:
ASCE 7-10
The 6th Edition(2017)of the Florida Building Code
s et: 2 of 2
S.
.No 004.4089
' STATE OF
John J. Orlando PE LLC 0044089
165 Old Ridge Road
Macon, GA 31211 •Q
(478)731-5394 ��I1VA i
jjorlando@cox.net
• •
apU� �w 0
f
i�