Loading...
HomeMy WebLinkAbout19-22158 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22158 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 22158 Address: 6420 LAURELWOOD DR Permit Type: RE-ROOF ZEPHYRHILLS, FL. Class of Work: ROOF REPLACEMENT Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVER OAKS Est. Value: Parcel Number: 03-26-21-0190-00000-0080 Improv. Cost: 7,980.00 ' I r OWNER INFORMATION Date Issued: 12/11/2019 Name: PINKSTON, BRENT D & MELISSA KEY Total Fees: 80.00 Address: 6420 LAURELWOOD DR Amount Paid: 80.00 ZEPHYRHILLS, FL. 33542-4869 Date Paid: 12/11/2019 Phone: 813-690-7824 Work Desc: REROOF SHINGLE CONTRACTORS APPLICATION FEES FOSTER ROOFING ENTERPRISE INC REROOF RESIDENTIAL 80.00} n o G 1 DRY IN ROOF IN P Ins ections Required TAPE JOINTS ROOF INSP FINAL REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CON R ATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-760-0020 City of Zephyrhills Permit Application Fato-913-780-0021 Binding Department note Received Phone Contact for PermitOn 'JylOwnels Name Owner Phone Number lD O� Owner's Address Owner Phone Ntmrhw 3-� 371�L Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS tw Opp Lt,L/L I kkV41 FD1 /L�OT�i#��y SUBDIVISION 1 �G 11', PARCELIDM (OBTAMM FROM PROPGMTAY NDTII2J WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = = DEMOLISH B INSTALL B REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION 0 BLOCK 0 FRAME = STEEL 0 DESCRIPTION OF WORK L BUILDING SIZE SO FOOTAGE HdGHT =BUILDING $ �%1, VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ U VV AMP SERVICE Q PROGRESS ENERGY Q W.R.E.0 =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED I YIN FEE CURREA I Y/N Address Ucerse# ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/N FEE CURREn Y—/N71 Address License# PLUMBER COMPANY SIGNATURE REGISTERED I YIN I FEECURREr. I YIN Address License# MECHANICAL COMPANY SIGNATURE I REGISTERED I Y/N FEE CURREA )/N Address x License# OTHER COMPANY OS S Z '�YIt�J SIGNATURE REGISTERED ILVI N FEE CURRM /aaN 40 Li I CM Address 9 .# Ispol III 111111 11111111111111lollIIIIIIIIIIIIIII111111IIIIIIIIII11111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fonts;RAW Permit for new consWction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Storrtwater Plans w/Sift Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivislons/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after Submittal date. Required onsite,Construction Plans,Stornwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.AI commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. Directions:• FII out application completely. Owner&Contractor sign back of application,notarized If over S25M a Notice of Commencement is required. (XC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone uft notarzed letter from owner authaiang Same OVER THE COUNTER PERMITTING (Front of Applrad-Orly) Retools if shingles Sewers Service Upgrades A/C Fens 0%t/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed'restrictions' which may he more restrictive than County regulations. The undersigned assumes,responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-a47- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTMILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 8"7 and 90-07, as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,600.00 or more,I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien taw—Homeowners Protection Guide°prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work Will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I'understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V°unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone"A"in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs,wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate;cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced_ An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COfAMENCEMENT. FLORIOA JURAT(F.5 V.03) OWNER OR AGENT CONTRACTOR bs swo to(or affirmed) this hsrn and svro to(or atfirrreed)bef�Le me ws .• hy by )rr+/Yt �t•[]S G� Who fare pe alty kno t me or hasRtave produced Who islare person wn to me hasRrave produced aseidentifiration. as identification. TVLIJt J(iJ�.� PLf Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Fl HEATHER D HOSFELD :_,; HEATHER D HOSFELD f'. Notary Public-State of Florida '--`:, Notary Public-State of Florida8 • _ Commission a GG 18'298 Commission-GG'c�"298 «, My Comm.Expires Mar 21.2022 '• fir`' my Comm.Expires Mar 2 2022- 6onded through National Notary Assn. Bonded through National Notary Assn. I INSTR#2019202615 OR BK 10013 PG 2025 page 1 of 1 S/H 11/26/2019 03:08 PIVI Rcpt:2112235 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles.Esa..Pasco County Clerk&Comptroller %scc) Permit Nffber Key lklumber NOTICE OF COMMENCEMENT TmsARiy,.mRmewmfmCumoFTmCoLwCwmFm*noN THE:umDERmNE.D hereby om noace tbat h;xmww4s vrz te MWO to certain red pqww,aril in acconfam ub Section 713.of the JM=dow of poperty(iWdh=*p&b* 673 a)SftWVAAndress - 6'VIO 4-g—,tj1eA.,C46e1 z e- v, 4;11J' 33--5'Y2 10wwS dwalpfion of bpovements: Reroof 3.OwnerInkinwdonorlessee— ffftLqsseecwnctedfix:tI*bV7mnent:, a)Nameaui 7,e',7 ea ks.,toa eY2.17 LivyrehynC4 /1 -&4. b)Kam and zNrm of tee dmpb Welhokler(ff ffaerd than Owner Wad abova) c)Interest in Ixopertsf. 4.Contractor Infommllion a)Nam sW address Fostees-Ropflit Enterprises P.O.Sox 633-Bfooksville,FL 34605 b)Telq*om No.:(352)799-0045 Fax No_(0pgNA(362)544-1003 &Su"(if Wkabbe,a copy of the pWoftbond Is WWdW) a)Nave and addrem b)Tek0one No:. c)Amount of Bond: &Lawler A Nam and address b)TekphmNo.: 7.Personswilhin the Slate ofFW*h&sWftd by u�w Q=nodcap or obardocturaftnW be urvad asp wMed by Secdon 71&13(1)(a)7.,Florida Statutes a)Nam and address b)T**mNoy &a.In adMonto himsellierhasellf,OwwdesilpWm of to receive a copy of the Lknoes Nafice as provkled in Section 713.13(1)(b),Flb;-WaStaTutee � I;Ybons MNrdwof Person croft&Wg.-xdW by Owner 9.ExpbMon date of noticed Woommement(the exph4on dift rray not ba balbra the m0edonof conarucillon sul&W p*mttothe con;trador,but VA be 1 ywftm the daft of ecorft w*=a 411srarit date lls q*ffaM: .20 WARN M TO OYMER:ANY PAYWDITS WWX BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COLUSICBM ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I.SECTION 71113,HDRIDA SMUTM AND CAN RESULT 01 YOUR PAYING TWE FOR WROVE]KNM TO YOUR PROPERTY.A NOTICE OF COWEMMENT KIIST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST IINSPECTIOW IF YOU 1NfM010 OBTAIN RWMW.,CONSULT WTH YOM LENDER OR-AN ATTORMB -WMOR RECORDING YUURiEO-i=OF'COLVAEMCEUM. x p0aseal 0 Or OWOM Of LMMS(Auff=Md Ir-IWWLBPP- . Sbft of tWIW—A cwzdyot— !'�74 e.o* The foregolM irannytent was bdo ft day of Y-0 V.Z,Z' .2D-2—_ by as for Pen"allyl(now 0 Oroduced 10 E!r Type oflo A4afaaynre DOUGILMICLOWES W DoijGLAS CLOVES uMay2O.2D22 -v Corm #GG 210741' E*wmatn.2022, �►,�° • `O`�� STATE OF FLORIDA, COUNTY OF PASCO THIS IS TO CERTIFY THAT T HE FOREGOING IS A • 'kY s. o TRUE AND CORRECT COPY OF THE DOCUMENT God wL�•iect ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNESS MY HAND A�D OFFICIAL SEAL THIS • �7 2 --DAY OF t�P—A 2pI CLER &COMPTROLLER B . DEPUTY CLERK 12/3/2019 Florida Building Code Online . q r ; t: • �- . ,_.. w .. fit" :,: ...: .. -�;�� '. aCIS Home I'Log In l User Registration t Hot Topics Submit Surcharge I Stats&Facts Publications ! Contact Us 4 BCIS Site Map 1 LMks Search Product Approval i, USER:Public User q xhac i r Product Approval Menu>Product or Application Search>Application Ust>Application Detail FL# FL7006-R10 Application Type Revision Code Version 2017 Application Status Approved *Approved by DSPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived r Product Manufacturer IKO Industries Ltd Address/Phone/Email 40 Hansen Road South Brampton,NON-US L6W 3H4 (905)457-2880 Ext 4581 william.liu@iko.com Authorized Signature William Liu william.liu@iko.com Technical Representative Bob Metz Address/Phone/Email REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727)776-5261 rmetzOO1@tampabay.rr.com Quality Assurance Representative Don Shaw Address/Phone/Email IKO Industries LTD 120 Hay Rd. Wilmington,DE 19808 (717)579-6706 don.shaw@iko.com Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency FM Approvals Validated By Locke Bowden P.E. tki Validation Checklist- Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 modified to 110 mph 2016 ASTM D3462 2010 ASTM D7158 Class H 2O11 ASTM E108 2011 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K6mXtoZLhNVX8Xpl%2f[ZtFYIIVL4hTrrOTA°/`3d%3d 1/3 12/3/2019 Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 10/08/2017 Date Validated 10/30/2017 Date Pending FBC Approval Date Approved 11/01/2017 Summary of Products FL# Model, Number or Name Description 7006.1 Cambridge,Cambridge HD,Biltmore Laminated architectural fiberglass asphalt shingle and Biltmore HD manufactured at IKO's Kankakee, IL; Hawkesbury,Ont.; Wilmington, DE; Sylacauga,AL and Toronto,Ont. plants Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 R10 C CAC Letter-ASTM D3161 letter-(9-26- Approved for use outside HVHZ:Yes 2017)from FM.pdf Impact Resistant: N/A FL7006 R10 C CAC Letter-ASTM D3462 letter-(9-26- Design Pressure: N/A 2017),pdf Other: FL7006 R10 C CAC Letter-ASTM E108 letter-(9-26- 2017)_pdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 II IKO-187-02-01 Letter-Installation Instructions for FBC FL7006.pd Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.2 Hip and Ridge 12 Cap This is a 12"x 12"fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured at IKO's Kankakee,IL,Toronto,Ont.and Brampton,Ontario plants. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 R10 C CAC ASTM D 3462-Shingle letter Approved for use outside HVHZ:Yes Surveillance Audit Location- (6-28-2017)_pdf Impact Resistant: N/A FL7006 R10 C CAC Letter-ASTM D3161 letter-(9-26- Design Pressure: N/A 2017)from FM.pdf Other: FL7006 R10 C CAC Letter-ASTM D3462 letter-(9-26- 2017),pdf FL7006 R10 C CAC Letter-ASTM E108 letter-(9-26- 2017),pdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 II Hip and Ridae Cap Shingle Installation Instructions.pdf FL7006 R10 II IKO-187-02-01 Letter-Installation Instructions for FBC FL7006.12d Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury,Ontario plants Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 R10 C CAC Letter-ASTM D3161 letter-(9-26- Approved for use outside HVHZ:Yes 2=)from FM -df Impact Resistant: N/A FL7006 R10 C CAC Letter-ASTM D3462 letter-(9-26- Design Pressure: N/A 2017),pdf Other: FL7006 R10 C CAC Letter-ASTM E108 letter-(9-26- 2017)_pdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 II IKO-1S7-02-01 Letter-Installation Instructions for FBC FL7006.pdf FL7006 R10 II Roofing-Products-Lead ing-Edge-Plus- Application-EN(1)_pdf Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K6mXtoZLhNVX8Xpl%2flZtFYIIVL4hTrrOTA%3d%3d 213 CONSTRUCTION MATERIALS TECHNOLOGIES October 27, 2017 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions—3-Tab Shingles (EN-3Tab_Appins_8AGXEFS-2012-11—reformatted 2013-02-rev07/13-Florida) 2) IKO Laminated Shingles Application Instructions (EN-Laminated—Appins_8TTEFS-2012-04_reformatted 2013-02-rev07/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions (EN-Hipand Ridge 12_3HRTri-2013-08_reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions (EN-3LEP-Tri-2012-06—reformatted 2013-03) 5) ASTM D3161 Test Report(FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E.do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: A*7 Signed: 2 Brad Grzybo ski Duc Wrofessional Managing rector Florida RegiS-feredEngineer j�LzP.E.Number:65034 Date: October 27, 2017 Date: October 27, 2017 Attachments: A) IKO Shingle Application Instructions-3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-187-02-01 PRI Construction Materials Technologies,LLC. 6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:B13.621-5840 e-mail:materialstesting@pricmtcom WebSite:httpl/www.pdcmt.com KO Installation Instructions for Asphalt Shingles Page 2 of 5 IKO Shingle Application Instructions — 3-Talc Shingles (ASTM 133161, Class F— IKO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT:Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt edge, approx. 1"and 13"from each end and 1/2"above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21"per foot(600)or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES 1-0t2" 1-1lL" } rb SEALJNU STRIP NAILS NAILS DO NOT WAIL INTO OR ABOVE THE SEALING STRIP PRI Construction Materials Technologies,LLC. 6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:materialstesting@pricmtcom WebSite:hftpJ/www.pricmt.com I KQ Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions (ASTM D3161, Class F—Cambridge, Cambridge HD, and CRC,Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT:Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements,the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1"and 13" in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21"perfoot(60°)or more,use 6 nails per shingle placed as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". NAILING-STEEP SLOPES APPLICATION Use six nails as shown_ —► w t^ � .fir � ��� � �► r 1V —► � NAIL LINE - 6 378 t w. 01 11 f] NAILS CEMENT PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY.AND UNDERLAY PORTIONS OFTHE SHINGLE PRI Construction Materials Technologies,L-C.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:materialstesting@p6cmtcom WebSite:httpJ/www.prlcmt.com IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions (ASTM D3161, Class F—IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION.INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 51/8"(130 mm)exposure. (For a neater appearance,the top of each side of each piece has been factory trimmed on a 1"(25 mm)taper(see drawing). Bend each piece over the hip or ridge,and nail 5 5/8" (143 mm)above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note:To obtain a three-dimensional effect,(which is recommended,but not required),apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another,the lower piece extending about 3/4" (19 mm)further than the top piece(see diagram).The-final shingle should be set in cement,and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEYARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS.REVIEW ALL APPLICABLE BUILDING CODES,MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. arm w MM1 TAPER CUT 5 TB f 6W ti62m[t� 0 PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:materialstesting@pricmtcom WebSite:http://www.pdcmt.com IKO Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions (ASTM D3161, Class F—IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings,or drip edges to roof deck as required. 2. Each 39 3/8"x 131/4"(1000 mm x 336 mm)IKO Leading Edge Plus strip is perforated lengthwise for, separation into two(2)shingles.Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 mm x 168 mm)and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up,with the factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge and 1" (25 mm) in from each end. 4. Take the leftover 20"(500 mm)piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof.The shingle should overhang the rake edge by a nominal 1/4"(6 mm)minimum. Fasten.the shingle to the roof deck with fasteners located 3"to 4" (75 mm to 100 mm)from the rake edge and 1" (25 mm) in from each end. 5. Repeat Steps 3—4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge,with at least 3/8" (9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20 mm) into boards. Use 4 nails per shingle placed 3"to 4" (75 mm to 100 mm)from the eave edge and approximately 1"and 13"(25 mm and 330 mm)in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum. Fasten the shingles to the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge,4 nails per shingle: 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first-course field shingles and help keep them from lifting in high winds. PRI Construction Materials Technologies,U.C.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:materialstesting@pdcmtcom WebSite:httpl/www.pricmt.com .7. . .......... CONSTRUCTION MATERIALS TECHNOLOGIES October 27, 2017 IKO Industries, Ltd 120 Hay;Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions—3-Tab Shingles (EN-3Tab—Appins-8AGXEFS-2012-11—reformatted 2013-02-rev07/13-Florida) 2) IKO Laminated Shingles Application Instructions (EN-Laminated—Appins—BTTEFS-2012-04_reformatted 2013-02-rev07/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions (EN-HipandRidge12-3HRTri-2013-08—reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions (EN-3LEP-Tri-2012-06—reformatted 2013-03) 5) ASTM D3161 Test Report(FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E.do not have nor plan to acquire a financial interest in any companymanufacturing or distributing products for which the test reports are issued. Signed: i' Signed. Brad Grzybo) ski Duc T. uyen Managing Director Florida Regl•ere —fe--'onal Engineer P.E.Number:65034 Date: October 27, 2017 Date: October 27, 2017 Attachments: A) IKO Shingle Application Instructions-3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-187-02-01 PRI Construction Materials Technologies,L-C. 6412 Badger Drive Tampa,FL 33510 Tel:813-621-5777 Fax:813-621-5840 e-mail;materialstestnapricmtcom WebSite:httpJ/www.pr cmt.com IKQ Installation Ipstructions for As?halt Shingles Page 2 of 5 IKO Shingle Application Instructions — 3-Tab Shingles (ASTM D3161, Class F— IKO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONDUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE., IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 F13C. UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements,the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt edge,approx. 1"and 13"from each end and 1/2"above each cutout. Drive nails straight so that nail head is flush with, but not cuffing into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21"per foot(600)or more,use 6 nails per shingle placed as shown below. Ensure that no nail is within 2"of a joint/cutodt of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt plastic cement placed under the shingle 2"above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES =t 1-irz, 1-ir, LSEAUNG SW rA NAILSNAILS DO NOT MAIL INTO OR ABOVE THE SEAUNG STRIP PR(Construction Materials Toonotogies,LLC.6412 Badger Drive Tampa,FL 33610 Tei:813-621-5777 Fax:813-621-5840 e-mail:Mateiialstesfing&demLeom WebS1te:httr.1/www.pdcmtccm IKO Iristallation Instructions for Asphalt Shingles PSge 3 of 5 IKO Laminated Shingles Application Instructions (ASTM D3161, Class F—Cambridge, Cambridge HD, and CRC Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT:Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1"and 13"in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. . NAILING ON STEEP SLOPES: For steep slopes of 21"per foot(600)or more,use 6 nails per shingle placed as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". NAILING-STEEP SLOPES APPLICATION Use six rmiis asshown_ NAILLINE 6 31131 NAILS CEMENT PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE PRI Construction Materials Technologies,I.I.C.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:materialstesting@pdcmtcom WebSite:httpJ/www.prJcmt.com IKQ Installation instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions (ASTM D3161, Class F—IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 51/8"(130 mm)exposure. (For a neater appearance,the top of each side of each piece has been factory trimmed on a 1"(25 mm)taper(see drawing). Bend each piece over the hip or ridge,and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip,working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note:To obtain a three-dimensional effect,(which is recommended,but not required),apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another,the lower piece extending about 3/4" (19 mm)further than the top piece (see diagram).The final shingle should be set in cement,and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEYARE DESIGNED FOR USEAS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS.REVIEW ALLAPPLICABLE BUILDING CODES,MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. aw cr9mm� —' TAPFA CUT 5 Ur t 63V (t62a"n} PPJ Construction Materials Technologies,LLC. 6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:materialstesting@prlcmLcom WebSite:httpJ/www.pricmt.ccm I KO Installationdnstructions for - Aaph'alt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions (ASTM D3161, Class F—IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required. 2. Each'39 3/8"x 131/4"(1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for separation into two(2)shingles.Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 mm x 168 mm)and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up,with the factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum. Fasten the shingle to-the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge and 1" (25 mm) in from each end. 4. Take the leftover 20"(500 mm)piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof.The shingle should overhang the rake edge by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with fasteners located 3"to 4" (75 mm to 100 mm)from the rake edge and 1" (25 mm) in from each end. 5. Repeat Steps 3—4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge,with at least 3/8" (9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20 mm) into boards. Use 4 nails per shingle placed 3"to 4" (75 mm to 100 mm)from the eave edge and approximately 1"and 13"(25 mm and 330 mm)in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum. Fasten the shingles to the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge,4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first-course field shingles and help keep them from lifting in high-winds. PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:materialslesting@pricmtcom WebSite:httpllwww.pdcmt.com E City of Zephyrhills 5335 81'St uphyrhills FL 33542 (813)780-0020 • "y t C i ROOFING INSPECTION AFFIDAVIT !� No.: �Permit �,,, ` 2 I f I ` licensed under Chapter468,Florida Statutes as a(n): Contractor License No. Engineer_Architect_ Building Inspector i �' 01 ► `NCO , k On or about 1p ' did personally inspect the: i Check: Roof Deck Nailing ✓ Dry in ✓ Flashing and Drip edge a.f I Check which was used: 30#felt Peel and Stick Other(List) a 11- ,fir C i At the following Lai)(-C6 Woo address: i i I Based upon that examination,I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual(Based on Section 553.844,Florida Statutes). t Signature: STATE OF F RIDA COUNTY OF PASCO Sworn to and subscribed before this day BY: I Notary Public State of Florida S-ELD HEN tER 0 H f ponds �' 1y"'• Notary pmbstonstate GG 161298 COm Tres that 11.2022 ••'�;.::5�x�:= My E°n' National Notary NSsn. d throufi9 Ronde i i