HomeMy WebLinkAbout19-22170 CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 22170 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:22170 Issued: 12/18/2019 Address: 6694 WAGON TRAIL ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 7,151.15 Total Fees: 187.50 Subdivision: SILVERADO Amount Paid: 187.50 Date Paid: 12/18/2019 Parcel Number: 05-26-21-0080-00600-0030 CONTRACTOR INFORMATION OWNER INFORMATION Name: MOMENTUM SOLAR Name: GONZALEZ, AUSTIN SCOTT & SCARLET Addr: 8248 PARKLINE BLVD STE 100 Address: 6694 WAGON TRAIL ST ORLANDO FL 32809 ZEPHYRHILLS, FL 33541 Phone: (321)247-6073 Lic: Phone: 813-323-5906 Work Desc: INSTALLATION PHOTO VOLTAIC SOLAR PANEL ROOF TOP APPLICATION FEES ELECTRICAL FEE 120.00 BUILDING FEE 67.50 INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL 16P REINSPECTION FEES:(c)With respect to Reinspection fees will compl ith Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. CONTRA TOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO V' CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I ® DATE(MWDDIYYYY) A`oRV CERTIFICATE OF LIABILITY INSURANCE 12/11/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Lisa MacDonald AAI CISR NAME Brown&Brown Insurance of Delaware Valley PnHic No Ex , (732)504-2001 A/C No): (732)504-2011 2000 Midlantic Dr,Suite 440 E-MAIL Imacdonald@bbdvins.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC 0 Mt Laurel NJ 08054 INSURER A: Gotham Insurance Company 25569 INSURED INSURER B: United States Fire Insurance Company 21113 Pro Custom Solar LLC dba Momentum Solar INSURER C: Lloyd's dba Momentum Home INSURER D: 8248 Parkline Blvd.,Suite 100 INSURER E: Orlando FL 32809 INSURERF: COVERAGES CERTIFICATE NUMBER: 19-20 Master FL REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OFINSURANCE POLICY EFF POLICY EXP LIMITS LTR INSD WVD POLICY NUMBER MWDD MMIDDNYYY COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE ®OCCUR PREMISES Ea=rence $ 100'000 MED EXP(Arty oneperson) $ 5,000 A GL201900010726 12/12/2019 04/21/2020 PERSONAL&ADV INJURY $ 1,000.000 M 'LAGGREGATELIMITAPPLIESPER GENERALAGGREGATE $ 2,000,000 POLICY ECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANYAUTO BODILYINJURY(Perperson) $ g OWNED SCHEDULED 133-745523-3 04/21/2019 04/21/2020 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident H $ UMBRELLALIAB X OCCUR EACH OCCURRENCE $ 5,000,000 A EXCESS LIAB ICLAIMS-MADE UM201900004884 12/12/2019 04/21/2020 AGGREGATE $ 5,000,000 DED I X RETENTION$ 10,000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETOR/PARTNERIEXECUTIVE ❑ NIA E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Professional Liability Limit 1,000,000 C Claims Made ANE1860007.18 12/12/2018 04/21/2020 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Cameron Christensen:CVC57036 Matthew Franz:EC13008217 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THEABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN City of Zephyrhills ACCORDANCE WITH THE POLICY PROVISIONS. 5335 8th Street AUTHORIZED REPRESENTATIVE Zephyrhills FL 33542 — — 01988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD J I I 1'0,mentum solar L Matthew Franz ,license holder for Momentum Solar,authorize the following individuals to apply,pick up,and sign for permits under my license number EC13008217 . Please allow ONLY the person(s)listed below to sign.This letter supersedes all others. Robert Johnson Michele Homstrom Jose Gomez Philip Reese Dawn Welch - Matthew Franz �c'to s mature Contractor's Printed, Name State of Florida County of Hillsborough The foregoing instrument was acknowledged before me this IL day of U� — , 20 19 By Matthew Franz who is personally Down to me or has produced as identification. oitpYruB� KRISIINASALGADO NOTARY PUB _ •' MY CoMMjsSIoN#GG 014460 * * EXPIRES:July 2i,2020 9onaodrnry6uagasxo+uYsWAM CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 22170 ELECTRICAL PER PERMIT INFORMATION , LOCATION-,! -.OR Permit#:22170 Issued: Address: 6694 WAGON TRAIL ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Proposed Use: NOT APPLICABLE ot(s): BI Section: Sq. Feet: Est.Value: o . Page: Cost: _ __ _ 15 tal Fees: 187.50 Subdivision: SILVERADO Am aid: ate Paid: Parcel Number: 05-26-21-0080-00600-0030 CONTRA O INFO ATION OWNER'N - RMATION N me: MOMENTUM SOLAR Name: GONZALEZ, AUSTIN SCOTT & SCARLET A dr: 8248 PARKLINE BLVD S 100 Address: 6694 WAGON TRAIL ST ORLANDO FL 32809 ZEPHYRHILLS, FL 33541 Ph e: (321)247-6073 Lic: Phone: 813-323-5906 Wbsk Desc: INSTALLATION PHOTO VOLTAIC SOLAR PANEL ROOF TOP APPLICATION FEES . ELECTRICAL FEE 120.00 BUILDING FEE 67.50 INSPECTIONS_REQUIRED_ ROUGH ELECTRIC CONSTRUCTION POLEy - =--- PRE-METER FINAL jam, "") g E., l� foe 7 REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute .80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. CONTRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department �7 ( I Date Received 2— 2—` phone Contact for Permittin 407 477_ 2219 Owner's Name Austin Gonzalez Owner Phone Number 813-323-5906 Owner's Address 1 6694 Wagon Trail Street Zephyrhllls,FL 33541 Owner Phone Number Fee Simple Titleholder Name F Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6694 Wagon Trail Street Zephyrhllls,FL LOT# SUBDIVISION Silverado Ranch PARCEL ID# 0526210080006000030 (OBTAINED FROM PROPERTY TAR NOTICE) WORK PROPOSED e NEW CONSTR® ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE © SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK E=] FRAME = STEEL DESCRIPTION OF WORK Installation of photo voltaic solar panels on rooftop 8.1 K BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $7151.15 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING $ (jam\`�`✓-�t�1•��6 MECH N C L y`� �\ i = A 1 A $ VALUATION OF MECHANICAL INSTALLATION ) =GAS = ROOFING 0 SPECIALTY L_J OTHER v FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER .(AOMPANY• Momentum Solar• , ' SIGNATURE REGISTERED Y/ N FEECURREn L11N Address 6210 Hoffner Ave Ste 1 Orlando,FL 32822 License# CVC57036 ELECTRICIAN �/y� �G COMPANY Momentum Solar SIGNATURE / // REGISTERED Y/ N FEE CURREN Y/N N� ' Address 6201 Hoffner Ave Ste 1 Orlando,FL 32822 License# EC13008217 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEECURREA Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREP LILN Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREr Y/N Address License# IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new Construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs If shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter If on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for.the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commending construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced Within six months of permit issuance, or'if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTORI Subscribed and swom to(or affirmed)before me this Subscribed and svign to(or affirmedbefore me this by h si \ck as-')� Who is/are personally known to me or has/have produced Who is/are p nally kno tome or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Com s 'On n I( Name of Notary typed,printed or stamped Name of Notary typ r P5UNE BOGES ,,.Commission 9 GG 276457 December 12,2022 Rolled 8W=4019 Parcel ID 05-26-21-0080-00600-0030 (Card: 1 of 1) Classification 00100-Single Family Mailing Address Property Value GONZALEZ AUSTIN SCO17& Ag Land $0 SCARLETTJANE Land $24,478 6694 WAGON TRAIL ST Building $148,701 ZEPHYRHILLS,FL 33541-2558 Extra Features $1,621 Physical Address 6694 WAGON TRAIL STREET,ZEPHYRHILLS,FL 33541 3ust Value $174,800 Assessed(Non-School Amendment 1) $174,800 Legal Description(First 200 characters) Homestead -$25,000 See Plat for this Subdivision Additional Homestead -$25,000 SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 075 BLOCK 6 LOT 3 OR 9738 PG 1432 Non-School Taxable Value $124,800 3urisdiction School District Taxable Value $149,800 CITY OF ZEPHYRHILLS Land Detail(Card: 1 of 1) Line _Use Code Description Zoning Units Type Price 'Condition Value 1 010OR LPl-1 SFR MPUD 6,000.00 SF $4.00 1.00 $24,000 2 010OR LP1-2 SFR MPUD 1,195.00 SF $0.40 1.00 $478 Additional Land Information Acres Tax Area FEMA Code Res Code Com Code Condo Code 0.17 30SI -- SLVR SLVR SLVR View Sketch Building Information -Use 0100-Single Family Residential(Card: 1 of 1) Year Built 2018 Stories 1.0 Exterior Wall 1 Concrete Block Stucco Exterior Wall 2 None Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle Interior Wall i Drywall Interior Wall 2 None Flooring 1 Ceramic Clay Tile Flooring 2 Carpet Fuel Electric Heat Forced Air-Ducted /C Central Baths 2.0 Line Code !Description Sq.Feet Value LIVING AREA-- - 6--- - --- - 1,84 -- - - - - $133,969 — - 2 -- -FGR0 ----- - - - - FINISHED GARAGE - -- -- - 441- -- - - $12,773 3 FOP01 FINISHED OPEN PORCH 108 $1,959 Extra Features(Card: 1 of 1) Line Code Description Year ,Units Value 1 RDWSWC DRVWAY/SIDEWALK CONC 2018 638 $1,621 Sales History Previous Owner: D R HORTON INC Month/Year Book/Page Type DOR Code Condition Amount 06/2018 9738/1432 War ran Deed 01 Vacant $213,000 12/2017 9649/0964 Warranty Deed 05 Vacant $0 OS/2017 4535/0546 Certificate of Title 05 Vacant $0 11/2016 9462/0384 Mineral Rights or Royalty Transfer 05 Vacant $0 04/2016 9364/0688 Mineral Rights or Royalty Transfer 05 Vacant $0 03/2016 9356/1231 Mineral Rights or Royalty Transfer 05 Vacant $0 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: LIZ Site: Permit Type: l 41, cl') � YP �� Approved Who comments: Approved w/the below comments: ❑ Denied w/the below comments: El This comment s eet shall be kept with the permit and/or plans. DEC 1 6, 2019 Kalvin itzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#2019204403 OR BK 100 15 PG 888 Page 1 of 1 12/02/2019 01:09 PM Ropt:2113159 Rec:10.00 IDS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller Permit Number Folio/Parcel ID M 0526210080006000030 Prepared by. Lauren EI-Taher/Momentum Solar 6210 Haffner Ave,Suite 1, Orlando,FL 32822 Return to: Momentum Solar 6210 Haffner Ave,Suite I Orlando,FL 32822 NOTICE OF COMMENCEMENT State of Florida,County of The undersigned hereby gives notice that improvement Will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,the following Information is provided In this Notice of Commencement. 1. Description of property(legal description of the property,and street address if available) Silverado Ranch Subdivision Phases 6,8&9A PB 75 PG/6694 Wagon Trail St.-Z.-ep rKWs.f:L*-555%4L 2. General description of improvement Installation of Photo Votaic solar panels on rooftop. 3. Owner information or Lessee information If the Lessee contracted for the Improvement Name Austin Gonzalez Address 6694 Wagon Trail St.Zephyrhills,FL 33541 Interest In Property.Owner Name and address of fee simple titleholder(if different from Owner listed above) Name N/A Address 4. Contractor Name Momentum Solar Cameron Christensen Telephone Number 321-247-60*73 Address 6210 Haffner Ave,Suite 1,Orlando,FL 32822 5. Surety(if applicable,a copy of the payment bond Is attached) Name N/A Telephone Number Address Amount of Bond 6. Lender Name N/A Telephone Number Address 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by§713.13(1)(a)7,Florida Statutes. Name N/A Telephone Number Address 8. In addition to himself or herself,Owner designates the following to receive a copy of the Liences Notice as provided in§713.13(1)(b),Florida Statutes. Name N/A Telephone Number Address 9. Explration date of notice of commencement(the expiration date will be I year from the date of recording unless a different date Is specified) WARNING TO OWNER.ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 71&13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT AT WITH YQUR LEN ER ORAN TORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Owner Signature Of Owner or Lessee,or Owners or Lessee's Authorized Officer/Director/Partner/Manager Signatory's Title/Office The foregoing instrument was ackhbiwledged before me this 29 day of 11/19 by Austin Gonzalez monthtyeaF,'. name.6f.person as Owner for Type of authority,e.g.,officer,trustee,attorney in fact' Name of party on behalf of whom instrument was executed `Z, n —Signature of Notai-y Public-(Vale of Florida Print,type,or stamp commissioned nanV of Notary Public Personally Known PR Produced ID X Of p4ra, KRISTINAS&GADO Type of ID Produced D.L. My COMMISSION#GG 01446D EXPIRES:July 21.2020 I i I I I i i CIIR� Aj• TAT!~OF FLORIDA,COUNTY OF PAaC® THIS IS TO CERTIFY THAT THE FOREGOING IS A.TRUE AND CORRECT COPY OF THE DOCUMENT ' ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNES MY HAND ND OFFICI L SEAL THI • 6"4 _ DAY OF CI_ ® LERK&COMPTROLLER BY 1 DEPUTY CLERK I � e Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 StudioGdesign@comcast.net November 28,2019 Re:Proposed Photovoltaic Solar Panel Installation Austin Gonalez 6694 Wagon Trail St Zephyrhills,FL 33541 Dear Plan Reviewer: Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the following recommendations: 1.The array will be installed on the existing roof.The roof framing is constructed of 2"x4"wood trusses @24"o.c. spanning 217'with a top chord length of 23'4"with intermediate supports at 1/3rd points,making the effective longest span equals TY with with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf.overall to the roof.No additional structural support is required for the roof structure. 2.The system shall be secured to the roof using the"Ecofasten Solar""Rock-IT"®attachment system.The installation shall be in strict compliance with manufacturers printed instructions.The attachment system shall be UL 1703 approved tested.The attachments shall be min.5/16"x 4"long stainless-steel lags with a min.embedment of 3" into the rafters.Attachments shall be @ 48"o.c.max.in roof wind zone 1,@ 24"o.c.max. in roof wind zone 2,&3, lags to alternate rafters.Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual.The panel angle shall match the roof slope. 3. Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. 4.Positive drainage of the system shall be so as not to void the existing roof warranty. 5.All aspects of the installation shall comply with the Florida Administrative Code,2017 Florida Building Code- Residential Sixth Edition,ASCE-7-10,2017 Florida Building Code—Energy Conservation,Sixth Edition,2014 National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by law.All components used meet the criteria of the Florida Solar Energy Center. 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. IF Daniel W.Dunzik,RA.LEED-AP FL.Lic.No.AR98795 '; AR98795 { f Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 StudioGdesign@comcast.net November 28,2019 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-10 Dead Loads= 10 psf+2.6 psf(new solar panels)= 12.6 psf Roof Live Load=20 psf Ground Snow Load=0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-10,Ch.30 method 1 Using an area of 10 SF,wind loads from Figure 30.5-1: Zone 1 =-32.3 psf Roof Slope=25 degrees Roof Mean Height= 15 ft Zone 2=-56.2 psf Basic Wind Speed= 140 mph Zone 3=-83.1 psf Exposure=B Per section 2.4.1,ASD combo=D+0.6W: Zone 1 =2.6 psf+0.6(-32.3 psf)_-16.8 psf Zone 2=2.6 psf+0.6(-56.2 psfl=-31.1 psf Zone 3 =2.6 psf+0.6(-83.1 psf)_-47.3 psf Check Attachment to Wood Truss Use 5116 dia.Lag screw w/3"embedment into 2 in.wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone 1 = 48"o.c.max Zone 1 =(48"o.c.max)^2/ 144= 16 SF Zone 2= 24"o.c.max Zone 2=(24"o.c.max),,2/ 144=4 SF Zone 3 = 24"o.c.max Zone 3 =(24"o.c.max)^2/ 144=4 SF Lag Screw Forces: W=2661b/in(Table 12.2A,2015 NDS) Zone 1 = 16.8 psf x 16 SF=269 lb < W', OK Cd= 1.6(Table 2.3.2,2015 NDS) Zone 2=31.1 psf x 4 SF= 124 lb < W', OK Ct= 1 (Table 2.3.3,2015 NDS) Zone 3 =47.3 psf x 4 SF= 189 lb < W', OK W'=W x embed x Cd x Ct W'=266 lb/in x 3 in.xl.6 x 1 = 1276.8 lb powered by WNW DUO. , Q.ANTUMQE A QUO BLk-G5 '\, 3 06-3'2011. . AR MODULE The new Q.PEAK DUO-DLK-G5 solar module from.Q CELLS impresses with its outstanding visual.appearance and particularly high performance on a small-surface thanks to.the innovative Q.ANTUM DUO technology. Q.ANTU.M's.world-record=hold ink cell concept-has now-been:combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions — both with low-intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY �J Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.3%. r INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the.weather with excellent low-light and temperature behavior. J ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID technology, OCELLS. Anti PI Technology', Hot-Spot Protect and Traceable QualityTra.QTM'. 7P-BR-ANDEXTREME WEATHER RATINGHigh-tech aluminum alloy frame,certified for high snow (5400 Pa)and wind loads(4000 Pa)regarding IEC. O A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year puenty Tested linear performance guaranteez. n STATE.OF THE ART MODULE TECHNOLOGY lo.aooszse7 Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. I APT test conditions according to IECfrS 62804-1:2015, method B(-1500V,168h) z See data sheet on rear for further THE IDEAL SOLUTION FOR: information. Rooftop arrays on " residential buildings Engineered in-Germany OCELLS K � SPECIFICATIONMECHANICAL Format 66.3 in x 39.4in x 1.26 in(including frame) (1685mm x 1000mm x 32mm) Weight 41.2lbs(18.7kg) + + Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology Back Cover Composite film na. , Frame Black anodized aluminum Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells • aw„ .Junction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83in (70-85mm x 50-70mm x 13-21mm),decentralized,IP67 °.. Cable 4mm2 Solar cable;(+)a43.3in(1100mm),(-)a43.3in 0100mm) I I ° , ir Connector Multi-Contact MC4,IP65 and IP68 *­_I-(=ijomr6S ELECTRICAL CHARACTERISTICS POWER CLASS 300 305 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) Power at MP?2 PH" IW1 300 305 310 315 320 Short Circuit Current* I,c [A] 9.72 9.78 9.83 9.89 9.94 e .Open Circuit Voltage* Vac IV] 39.48 39.75 40.02 40.29 40.56 E Current at MPP• I„p [A] 9.25 9.31 9.36 9.41 9.47 Voltage at MPP• V„p IV] 32.43 32.78 33.12 33.46 33.80 Eff)ciencyz [%] Z 17.8 z 18.1 218.4 Z 18.7 219.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOC' Power at MPP° PH" IW1 222.3 226.0 229.7 233.5 237.2 e Short Circuit Current* I,c [A] 7.84 7.88 7.93 7.97 8.02 e Open Circuit Voltage* V. IV] 36.93 37.18 37.43 37.69 37.94 'o _ Current at MPP• I„p [A] 7.28 7.32 7.36 7.41 7.45 Voltage at MPP,• Vmp IV] 30.55 30.88 31.20 31.52 31.84 11000W/m2,25°C,spectrum AM 1.513 r Measurement tolerances STC+3%;NOC x5% 380OW/m2,NOCT,spectrum AM 1.513 *typical values,actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ----� 7 -acn,s At least 98%of nominal power during first year. X , I , I W _ Thereafter max.0.54%degradation per year. Gu ----a------------' T I e ® ------------------------------- At least 93.1%of nominal power up to 10 years. a At least 85%of nominal power up to 25 years. - W I w All data within measurement tolerances. ® --�_____I I I --_-� e r_____I_____-_ I Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your s 2 respective country.� °oo e°o ,00a IRRADIANCE Iwhnrl z Q �mw.�robu.,°w m YEARSTypical module performance under low irradiance conditions in s„„"ak°°,'v,,,,,,,,•„m�,,,,°m„I,,,;y,,,,•,p,,, comparison to STC conditions(25°C,1000W/m2). TEMPERATURE COEFFICIENTS 0 Temperature Coefficient of l,c a [%/K) +0.04 Temperature Coefficient of V. P [%/Kl -0.28 d Temperature Coefficient of PH, y [%/K] -0.37 Normal d:Operating Cell Temperature NOCT [°F1 113 5.4(45 t3•C) p PROPERTIES 1. SYSTEM-DESIGN a 0 Maximum System Voltage Vow M 1000(IEC)/1000(UL) Safety Class I I a Maximum Seiies Fuse Rating [A OC] 20 Flre Rating. C(IEC)/TYPE 1(UL) o Design load,push(UL)' [Ibs/ft2l 75(360OPa) Permitted module temperature -40°17 up to+185°F on continuous duty (-40°C up to+85°C) Design load,pull(UL)2 [Ibs/fF1 55.6(2666Pa) 2 see installation manual 0 QUALIFICATIONS 1 CERTIFICATES PACKAGING INFORMATION UL 1703;VDE Quality Tested;CE-compliant; Number of Modules per Pallet 32 _ IEC 61215(Ed.2);IEC 61730(Ed.1)application class A 5 Number of Pallets per 53'Trailer 30 CE SP® Number of Pallets per40'High Cube Container 26 EVE ca,,•,us P allot Dimensions(LxWxN) 69.3 in x 45.3 in x 46.9 in _ (1760mm x 1150mm x 1190mm) Pallet Weight 1415lbs(642kg) - NOTE:Installation Instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. v, Hamvha 9 CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us L Data Sheet Enphase Microlmrerters Region,AMERICAS �� The high-powered'smart g dy Enphase IQ 7 Micrd"and Enphm 10 7+Micre 7 and Q 7+ +dramatim5i simplify the installation ploom while achiving,the highest system efficiency.. W 6a�nve rte rs mart of the Enphose 14 Systern the IQ 7 and IQ 7+Mieroinverters.integrate with the Erlphase iQ Envcy",.Enphase IQ Battery.",and the Enphase Enlighten"monitoring and analysis software. IQ Serles.Micxroinvverters extend the reliability standards set forth by previous generations and undergo artier a million hours of power-on testing, ertabling Enphaseto.praivldean Industry4eading warranty of up to 25 years. Easy to install • Lightweight and simple •.FeetertnstellationwKh lmpmved,Uphtertwo-e►iro oabllrq Gsl�irii • Bu0tdn rapid shutdown comp0am(NEC 2014&2017) Productin and Reliable --- • Opttmhed for high powered 60-cell and 72-ce0*modules •More than a m10lon bouts oftea" i. •Clews If double-Insulawd.nclosare UL 0sted Smart Grld'Ready •complies with advanced gild support,wltspe and i frequency d tdederthrevo mquiteme • Remotery updates to respond to chenghl; gdd requirements •ConfigumWefar varying gridproftlas • Mew CA Rule 21(UL 1741-"- *1M is�+Micro w.nrqulred�«+paort 72et0 modak,: To team more about Enphase.offeringa,*it enphsrmmm -EN PHASE. 1 L Enphase IQ 7 and IQ 7+ Microinvertem INPUT DATA'(OC) 107.60 2-Us1.icim0-S-us 147PLUSr72-2-USI.r47PLUS 72.8.us .Commonly used module pairings, .235W-350IN+ 235W-440W+ Module compatibility 60»colt PV modules only 60-con and 72-call PV modules Maximum input DC voltage 48 V 6o v Peak power tracking voltage 27 V-37 V 27 V-45V Operating range 16 V-48 V 16 V-60 V Mtn/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Ise) 16A 15A Overvoitage class VC port it 9 DC port baekfeed current 0 A 0 A PV array configuration Tx 1 ungrounded array,No additional DC side protection required; AC aide protection requires max20A per branch circuit' OUTPUT DATA(AC) 14 7 Microlmerter. 1111 74t Microlnverter Peak output power 50 VA'� 295 VA Maximum continuous output power 240 VA 290 VA Nominal(l-L)voitagehangen 240 V/ 2D8 V/ 24O V/ 208 V/ 211264 V 183-229 V 213 264 V 188-229v Maximum continuous output current 1:0 A(240 V) 115A(208 V} 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 fiz, Extended frequency range 47.68 liz 47=611 Hz AC short circuit fault current over 3 cycles 5.8 Arras 6.8 Aims Maximum units per 20 A(K)branch cireuNo 16-(240 VAC) 13(208 VAC) 13(240 VAC) 11(200 VAC) Ovenrottago class AC port IIi III AC port backfeed current 0 A 0 A Powerfactor setting 1.0 1.0 Power factor(adjustable) Vleading...0.7legging 0.7 leading...0.7 lagging EFFICIENCY LZ240 V @208 V IP140 V @208 V Peak=efficiency 97.531 97.6 t 47.8% 03% CEC weighted efficiency .97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperaturo range- 400C4a+660C Relative humidity range 4%+to 100%(condensing) Cannectortype(107.60.2.11S&1(VPLUS-72-24US) MC4(orAmphenol H4 U7X with additional Q-DCG5 adapter) Connactortypa(1Q7-60.8-U88,107PLl3S-72.8-U3).Friends PV2(MC4 intermateable). Adaptors for modules with M04 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 -PV2 to USX:order ECA-S20-826 Dimensions(MRxD) 212 mm x 176 mmx 30.2 mm(without bracket) .Weight 1.08 kg(2.38 ibs}' Coaling Natural convection-No fens Approved for wet locations yes Pollution degree PD3 Enclosure Class 11 doubtednsulated,corrosion resistant polymeric enclosure Environmental category UV exposure rating NEMA Type 6/outdoor- FEATURES Communleation PowarElne Communication(PLC) Monitoring Enlighten Manager and MyEnilghten monitoring options. Both options require Installation of an Enphase 10 Envoy, Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690, Compliance CA Rule 21(UL-1741=SA). UL 621.094,UL1741/IEEE1 S4Z FCC Part 15 Class 8, ICES-0003 Class 8. CAN/CSA-C22.2 NO.107.1-01 This product Is UL Usted an PV Rapid shut Down Equipment and conforms with 14EC-2014 and NE0,2017 section 69012 and C22.1.2015 Rule 64.218 Rapid Shutdown of PV Systems,for AC' and DC conductors,when installed according manufacturer's instructions. 1.No enforced aCMC ratio.See IN oampatlbmtycalculator attdtp4•r neheDeomren•n++l4uono finodille�nifi ly 2.Nominal voltage range can be extended beyond nominal If required by theutlitty. &Umito may vary.Refer tv local requliements to define the number of mirrolnverters per branch in your area. To learn more about Eslphaseofferings,visitenpbase.com = EN PHASE. 02018 Enphase EneW Ali rights reserved.All trademarks or brands used are the property of Enphase Enargy.lne.' 2018.05.24 a L Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman,NJ.08558 908-872-3664 January 29,2018 Building Department Attn:Plan Reviewer Re:Proposed Photovoltaic Solar Panel Installation Dear Sir: I have reviewed the following documents related to the"EcoFasten Solar"ROCK-IT SYSTEM 4.0 and certify that the attachment system when installed in strict compliance with the manufacturers Installation Manual appropriate for this application and is in compliance with the latest building codes including Florida Administrative Code,2017 Florida Building Code-Residential Sixth Edition, ASCE440,2017 Florida Building Code—Energy Conservation, Sixth Edition,2014 National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. I make this certification for the following listed documents: 1. ROCK-IT SYSTEM 4.0 Installation Manual 2. PZSE,Inc Structural Engineers Certification. 3. EcoFasten Solar Certificate No.US 82150026 4. ROCK-IT SYSTEM 4.0 Cut Sheet for Coupling,Hybrid Coupling, and Mount. If you have any questions relating to this matter,please contact me at your earliest convenience. Thank you. Daniel W. Dunzik,RA.LEED-AP ' Fl.Lic.No.AR98795 AR987 r I . 1 � Cut Sheet- Rock-It-4.0-Coupling 1. Installation to be completed in accordance with manufacturer's.wfitten specifications and installation instructions. . .2. See spec sheet or contact manufacturer for-detailed material,finishes,and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 3.17in ® ® ® L80:54rnm 7.00in j [177-80mm I i 2.02in 2.14in 2.34in » [51..38mm] [54.37mm! r59.36mm] _- 32mm 35mm 40mm ALPINE r`Z':1 i oFassten Solar"' 4741-W-Polk Stree Ste.4 N�VYGUII�DS Phoenix,AZ 85043 Toll.Free Phone 1.888.766.4273 Toll Free Phone 1,877,859.3947 Material:See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 - Scale: 1:4 6/28/2017 As - EFS: X Cut Sheet - Rock-It-44-Hybrid Coupling 1.. Installation to be completed in accordance with.manufacturer's written specifications and installation instructions. 2. See spec.sheet or contact manufacturer for detailed.material,finishes,and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 3.16in 0 0 [80.29mmN 7.00in 1177'.80m m] 5.00in 127mm- 1 2.02in 2.14in 2.34in d [51.38mm] [54.37mm] -[59.36mm"I u 32mm 35mm 40mm ALPINE `r 4741 W Polk Street Ste.4 .���'.�r XRD ''' ' J►�C I>� 0 �z` Phoenix,AZ'85043 Toll Free-Phone-1.888.766.4273 Toll'Free Phone-1:877:859.3947 Material:See Spec Sheet Toil Free Fax-1.888.766.9994 Toll Free Fax 1.888:766.9994 scale: 1:1 6/28/2017 ASG: - EFS: x E 91YtiE5s, •1 '" �6111f�r /I RCJ"C K-I.T SYSTEMP �.Q RAIL--FREE RACKING UTluzes ECFasTen SOLars PaTenTeD TecHnOLOGy ') Ect��as�ten'Solar v r Y. q�r -JC co s en Solaro Y Committed to the connection Document Date::9.8.2017 Contents Pg. 1......................................................................................................................... ............................. Assets of Design. -Features System Components Pg. 2 .............................................................................................................................. Rock-it 4.0 Mount Assembly Rock-It 4.0 Coupling Assembly Pg. . 3 ............................................I............................................................... Rock It 4.0 Hybrid Mount Assembly Rock-It.Clip SS Assemb,ly. Rock-it-Clip.-2.0..Assembly- Pg. 4.......................................................................................................................................................... Array Layout GreenFasten Flashing Install Pg. 5..........................4......................................................................................................... Rock-it System 4-0 Install Pg. 6.................................................................................................................................................. Ground Lug Install Pg. 7 .......................................................................................................................................... Rock-It-Clip SS Install Rock-it-Clip 2.0 Install Pg.-8 -12 ............................................................................................................................. Standoff.Spacing Tables Snow Load 0-20 psf Snow Load-21-30 psf Snow.Load 31-40 psf Snow Load.41-50 psf -Snow Load 51-60.psf Pg. IS ................................................................................................................................... Grounding Information' Bonding Assembly and Bonding Path :Pg. 14. ................I............................................................................................... Thermal-Expansion and Bonding Bracket:Spacing Staggered*Layout Cantilever Pg. 15.. . ................................................................................................................................... System Specifications Evaluated, Compatible'Modules r s ROCK-IT S�JSTeM 4.0 Designed with the installer in mind. EcoFasten.Solar specializes in solar roof attachments that are fast and easy to install,straightforward,secure and' cost-effective.EcoFasten offers a wide variety ofistandard products as well as custom solutions,.for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry standards in-house:and by third party agencies. EcoFasten's patented conical sealing system has been-in service in the.snow guard and solar industries for two decades. FeaTu res • New and improved design • North-South adjustability • Fastest;easiest to level system on the market • Only one tool-required(1/2"deep well socket) Integrated electricaI.bonding • Vertical adjustment of 3"-4" • SIMPLE-only 4 components S�J.STem componenTS* - reouireD Ilk ROCK-IT SLIDe ROCK-IT 4.0 ROCK-IT 4.0 COUPLinG ROCK-IT 4.0 4" For comp sHinGLe MOUnT & LOaD BearinG FOOT Array sKir r 8 For TILe SYSTem ComponenTS* - oPTIOnaL ®°0 UROCK-IT CLIP SS EcoFasten Solar-® ,g (ReFer TO PG.6) EcoFasten Solar products are protected by the following U.S.Patents: -8,151,522 8,153,700 8,181398 8,166,713 8,146,299 ROCK-IT 4.0 8,209,914 8,245,454 8,272,174 8,225,557 9MO.038 ROCK-IT 4,0 Array sKi rT 9,134,040 9,175,478-9,212,833 1-IuBnD MOunT EnD caps .(ReFer TO.PG. 5) Pre Taa�eo on EasT ROCK-IT CLIP 2.0 enD of sKirr secnons) (ReFer TO PG. 6) *Components for use with 32mm modules are available as special order.Components for use with 32mm modules are labeled as such on system packaging.Please refer to evaluated;.compatible modules grid on page 15 to Identify system compatible 32mm modules. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 1 r, ROCK-IT 4.0 MOUnT ASSeMBLY NOTe: ITems 1-7 SHIP assemBLeD 1 5/16"-18 x 1.75"Hex Serrated Flange Bolt 300 Series SS _ 2 Rock-It 4.0 Mid-Clamp 6000 Series AL 3 Rock-It 4.0 Shelf 6000 Series AL 4 Flange Level Nut 300 Series SS 5 Rock-it 4.0 Tie Plate 6000 Series AL 6 Rock-It Pedestal 6000 Series AL 64') ` ,b �� o ti 7 5/16"-18 x 3/8"Hex Serrated Flange Bolt 300 Series SS 3/8"ID Star Washer 300 Series SS 9 3/8"-16 x 3"Hex Tap Bolt 300 Series SS .f."� � I ROCK-IT SLIDes are accePTaBLe BracKeTS For j Use WITH ROCK-IT 4.0 (SOLD separaTeLg) ROCK-IT 4.0 COUPLING asSemBLY NOTe: ITems 1-3 SHIP assemBLeD i 1 5/16"-18 x 1.75"Hex Serrated Flange Bolt 300 Series SS = ---Y 2 Rock-It 4.0 Coupling Mid-Clamp 6000 Series AL ® 3 Rock-It 4.0 Coupling Shelf 6000 Series AL 4 Rock-it Load Bearing Foot Clip 99' ! 5 Rock-It Load Bearing Foot Base I 'J I www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 2 4 ROCK IT 4.0 HYBRID mounT ASSeMBLY. NOTe; ITemS 1-10 SHIP assemBLeD 1 Rock-It 4.0 Shelf 6000 Series AL 2 Rock-It 4.0 Coupling Mid-Clamp 6000 Series AL 10 3 Rock-It 4.0 Coupling Tie Plate6000 Series AL 4 Flange Level Nut 300 Series SS I \ r® 5 Rock-It Pedestal 6000 Series AL 6 Rock-It Slide 6000 Series AL � \ D 7 3/8"-16 x 3"Hex Tap Bolt 300 Series 55 8 3/8"ID Star Washer 300 Series S 9 5/16"-18 x 3/8"Hex Serrated Flange Bolt 300 Series SS 10 5/16"-18 x 1.5"Hex Serrated Flange Bolt 300 Series SS 0 I l�/ 11 .l� B �j Jr7 ROCK-IT CLIP SS ASSP_I'1'1BLy ROCK-IT CLIP 2.0 ASseMBLY NOTe: ITems 1-3 SHIP assemBLeD NOTe: ITems 1-3 SHIP assemBLeD 1 Stainless Steel Carriage Bolt-.313-18X.75 1 Rock-It Clip 2.0 2 Rock-It Clip SS 2 Stainless Steel Flange nut.313-18 3 Stainless Steel Flange nut.313-18 3 Bolt.3125-18x1x1-S www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 3 , r Array LayOUT • Find the required structural-attachment points. Mark these using a vertical(WS)chalk line on.the- center of the rafters: • Spacing may vary depending upon project specific structural requirementsj.'e:high snow-and wind load areas may require lesser bracket spacing in the E-W axis vs:the maximum-spacing.Max spacing is 48"for portrait orientation and-72".for landscape orientation:Consult project layout diagram for project specific bracket spacing on the,roof. • Install.Rock-it Mounts to predetermined mount spacing. • The RocWt.Array Skirt sections-are the width.of a typical 60.cell module.-.use the:Rock-lt Array Skirt as a.guide to lay out module placement. Note:The distance between the rows of mounts is calculated_bythe module dimension-WS plus 1 3/8" (35mm).Lag screw should be installed as close to center of exposed shingle as possible:The minimum. distance between the lag screw and the edge of.-the shingle is 1/2" GreenFaSTen"m FLasHrnG STaLL 1 Locate the rafters and snap horizontal and.verticaI lines to mark the installation a� r position for each GreenFasten flashing. 2. Drill a pilot hole(1/4"diameter)for the lag bolt Backfill-with sealant.EcoFasten Solar recommends an.EPDM mastic: 3 Insert the flashing so the top part is under.the next row of shingles and pushed far enough.up.slope to prevent water infiltration through vertical joint in shingles.The leadin ed e.offlashin must butt against upper row.of.nails to revent.tumin 9 9 9 9 PP P 9 when torqued. . 4. Line up pilot hole with GreenFasten flashing hole.. Insert the-lag-bolt through the EPDM bonded washer,the Rock-it slide,the gasketed hole in the flashing and into the rafter. Torque:The range Is between 100-140 torque inch-pounds depending on the type of wood and,time of year.The visual.indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses.If using an Impact wrench'to install the fasteners be.careful not to over- torques.the fastener.You may need to stop and use a ratchet to finish-the install. *The Engineer of Record shall-check capacity of rafter to support.lag_screw loading. wwwecofastensolarcom info@ecofastensolarcom 877-859-3947 4 : ROCK-IT SYSTCM 4;0 1nSTaLL Y 'MSB1{7 a-11,� J tit r� t `e i i9. Fig.A 1 Install EcoFasten.Solar Flashing with Rock-it,Mounts . •Follow Ecorasten Solar Install Instructions fWashIng and bracket Install(GreenFasten shown above). •Optimum vertical distancebetvaeen lag boks is 1 Wplus module cirmenslon. Set mounts on eave most row sothatthe Rodcat Pedestal is on theSouth end of Rock-ItSlide-' •-Set mounts on all upper mws so that the Rock It Pedestal Is on the North end of Rock-It slide 2 Install"Rock-It Array Skirt onto Eave Mounts Slide Rock-It Array Skirt Into front channel on Rock-It Shelf. Array Skirt End,Caps are pre,-installed an the East end of each skirt section,and are used to couple the skirt sections where needed(see Fig.A). Tighten Mid-Clamp bolt,clamping Rock-It Array Skirt to mount:Torque to 200lrr4bs(130In-lbs.when Installing with 32mm modules). _ Install Rock-It Couplings(when joining 4 panels with a Coupling,the use of a load bearing foot Is required) 34 "Prior to mounting on the roof,snap Load Bearing Foot Into the bottom of.Rock-It Coupling If required.. (Each Load Bearing Foot is set to same height as the Rock-It Mounts.-adjust accordingly) •.On eave row only,slide Rock=lt Array Skirt onto Rock-It Coupling Shelf.Torque to specified value • NOTE:If a coupling lands on a rafter,the Hybrid Mounte should be used In place of the Rock-It Coupling(refer to image 3a). *Hybrid Mount can be made in the field by assembling a coupling to amount Pedestal,or by purchasing separately. 5 Align and Straighten'First Row of.the Rock-It System with Rock-It Array Skirt •Use North-South adjustmentoftheRock-ItPedestaltostraightenRock4tArraySkirtandalignmodulewithArraySk(rt. •Torque screw.on side of Rock-It Pedestal to 150 In4bs to secure It to the Rock-It Slide. •Adjust Flange Level Nut to level the system(optional—can be leveled during or after installation). 6 '9 Install 1st Row of PV Modules- Slide upslope Rock-It Mounts down to engage top ci e ffirstmodul •Install Rock-It Couplings'on the upslope side of 1st row of panels. •Torque 2nd row ofIVIld4ampson Rock-it Mounts and RocMt Couplings to specified value. •Install balance ofPV modules,ensuring that the Rock-ft Peclestah am In the appropriate.position,then torque Mld-Camps to secure modules. . O Level the Rock-It System --When assembly Is complete;level the entire system by adjusting Flange Level Nuts(Flange Level Nuts have no torque value). • Height between roof surface and underside of modules should be 3'or less,when Installed with Type 2 modules INSTALLATION NOTE:Modules should.be'Installed so that the Junction box is installed upslope,away from the lead Ing-edgeof the array. www.ecofastensolarcom info@ecofastensoiarcom 877-859-3947 5 a r GrounanG LUG inSTaLL Necessary Components: - One of the following ground lugs(or any UL 2703 compliant ground lug): Burndy CL50-1TN Ground-Lug(UL 2703-E351343./ UL467-E9999). ILSCO SGB-4 Ground Lug(UL 2703-E354420 /UL 467-E34440). 1LSC0 GBL-4DBT(UL 2703-E354420 /UL 467-E34440) ILSCO GBL-4DBTH(UL 2703-E354420 /.UL 467-E34440) ILSCO GBL-4SS(UL 2703-E354420 /UL 467-E34440) Note:Drill and.deburr hole in Ground'Lug prior to installation - 14 AWG-4AW.G Copper Ground Wire* Torque Values: - $-32.x 0:5"Serrated Flange Head Bolt(300 Series SS) 14=10:AWG=20 in-Ibs. - 8-32 Serrated Flange Nut(300-Series SS) B.AWG=25 in-lbs. - 11/32"and.1/4"wrenches.or ratchets/sockets 6-4 AWG=.35 in-Ibs. 1 Insert the flange bolt Into the module.ground.hole.Place Star Washer over bolt.Place ground lug over the bolt.and Star.Washer,and turn to desired orientation. 2 .Install Flange Nut. 3 Tighten Flange Nut/Bolt. 4 Place wire in Ground Lug channel and tighten setscrew to.complete assembly. *Wire should besized in accordance with the National Electrical Code,NFPA 70;Section 690.45,and a minimum of 1/4"clearance required between bare copper wire and aluminum. ' Drlil.hole per.grounding lug manufacturers specifications in the upslope part of Rock4t Coupling t for attaching grounding lug. Note:Deburr-hole in Ground Lug and Rock-It Coupling prior to'installation. www:ecofastensolarcom info@ecofastensolarcom 877-859-3947 6 .ROCK-IT CLIP SS i n STa LL •arcenr�nlebtouelutglxa= � .-$ -21thfrom ienMon Roy a 1. Locate-all parts -Locate'the Rock It.Clip SS,micro-inverter/power optimizer;and-the section of the module.frame in which you.will be mounting.the micro-inverter/power optimizer. See fig.A for acceptable mounting locations. 2, Install the Rock-it Clip SS • Slide the.Rock4t Clip:SS onto the lip of the.module frame.. • Slide the micro-inverter/power optimizer into the opposite lip of the.Rock=.It Clip SS. - Tighten the bolt to-1 50 in-lb minumum to clamp.the Rock-it Clip SS to the module frame and the micro-inverter/power-optimizer to the Rock-it Clip SS. • .Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against the:ciip flange to avoid rotation during tightening. ROCK-IT CLIP 2.o- inST8LL Inverter Flange Module Frame Rock-lt Clip 2.0 1- Locate all parts -Locate the Rock-It.Clip 2.0,micro-inverter/power optimizer,and the section of the module frame in which you Will be mounting the micro-inverter/power optimizer. 2 Install the Rock-it Clip 10(See below detail) • Slide the Rock-it Clip 2.0 onto the lip of the micro-inverter%power optimizer. • Slide the,micro=inverter/power.optimizerdnto the opposite lip of the module frame. • Tighten the.bolt to 1.50 in-lb to clamp the Rock-It Clip 2.0 to the module frame and the micro-inverter/power optimizer to the Rock-it Clip 2.0. • Ensure that.the lip on the clip is tight.against the frame and that the micro-inverter/power optimizer.flange is tight against the clip flange to.avoid rotation during tightening. www.ecofastensolarcom info@ecofastensolarcom 877-859-3947 7 Snow Load 0-20 psf Modules in Landscape Wind Speed Exposure 2:12<Roof.Pltch•e 6:12 1. .7:12 a Roof Pitch a 12:12. ASCE 7-05 ASCE 7-10 Category, Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 159 93' 59 85 mph 110 mph C 114 67 42 88 88 D. 96 _ 56 35 91 74 '74 B 146 85 54 90 mph 115 mph C 104 61 38 98 80 80 D 88 51 32- 83 68 68 B 123 •72 45 95 ' 95 100 mph 125 mph' C 88 51 32 83 68 68 D 74 " 43 27. 70" 57 .57 B 98 57 36 93 76 �76 110.mph . 140 mph. C 70 41 26 66 54 54 D 59 34 22. 55 46. 46 B .85 50 31 81. 66 66 120 mph 150 mph. - .. C 61 36 22. .58 47 47 D 51 30 19 49 40 40 .Notes: Spacing Governed by Snow Load 1.)Values in above table represent the.maximum allowable spacing in Inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter.spacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag.pullout capacity 5.)Values based on a maximum module width of 40" 6.)Based on Risk Category 11(ASCE 7-10)'structures less than 30 feet in height 7.)All adjustment-factors are set to 1.No site specific engineering Is included in this table Snow toad'0 20 psf Wind Speed Exposure 2:12.<Roof Pitch.<6:12 1 712<Roof Pitch x'12:12 ASCE 7-05 ASCE 7=10 CAtegog Zonal Zone 2 Zone-3 Zone.1 Zone 2 one 3 -- _ -- - - B 91 - - -53.r.__--__33 85 mph 110 mph , C 65 38 24 61-. 60 -z50,irk:.` D 55 _ 32 2Q B 83 _ -49 30 90•mph 115 mph C 59 35 22 56 46 46 D 50 29 18. 47 38 -38 70_ 41—v 100 mph 125 mph C 50 29 18 47 "' ' 39 39p D 42 26 1 1.5.. , . .40 32 321 B 56 7 33 20 53 43 43 110 mph 140 mph. C 40 23 14 38 31 31 D 34 19 12 32 26 26 - — - B __ 49 _ —- 28 120 mph 150 mph C 35 20 12 33 27 27 D 29 17 10 28 22 22 Notes: _Spacing Governed by.Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2:)Maximum allowed spacing approved by EcoFasten Solar Is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.6 for-lag pullout capacity 5.)Values based on a maximum module length.of 70" 6:)Based on Risk Category Il(ASCE 7-10)structures less than 30 feet in height. 7.)All adjustment-factors are set to 1..No site specific engineering is included in this table www.ecofastensolarxom info@ecofastensolarcom 877=859-3947 '8: J a Snow Load 21-30 psf Modules in Landscape Wind Speed Exposure 2:12<Roof Pitch<.6:12 7:12<Roof Pitch-C I v ASCE 7-06 ASCE 7-10 Category Zone 1 Zone 2 Zone.3 Zone 1 Zone*2 . Zone 3 . B 93 59 85 mph 110 mph C •67 42 D 96 . 56 35 B 85 54 90•mph 115.mph C 104 61 38 D- 88 51. 32 B. 72 45' 100.mph 125'mph . C 88 51 32 D 74 - 43 27 57 57 B 98 57 36 110 mph 140 mph C 70 41 26 66 54 54 D 59 34 22 56 46 46 B . 85 50 31 66 66 120 mph 150 mph, C 61 - 36 22 58 47 47 D 51 30 19 49 40 40 Notes: Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.)Maximum allowed spacing approved by EcoFastan Solar Is-72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)includes additional factor of safety of.1.5 for lag pullout capacity 5.)Values based on a maximum-module width of 40" 6:)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is Included In this table Snow Load.21-30 psf. Wind.Speed Exposure 2:12<Roof Pitch<6:12 7:12'<Roof Pitch<12:12 ASCE 7-05' ASCE 7-10 Category Zonal Zone 2 Zone 3 Zone 1 Zone 2. Zone 3 B 53,E-1 .�''33v-22 85 mph 110 mph C ti5 38 24, l� �_ B 49 30 90 mph 115 mph C 59 35 22 D 50 29 18 38 38 100 mph , 125 mph J' C 50 29 18 D _ 42 _26, 15- B 56 33 20 110 mph 140 mph C 40 23 14 38 31 31 D 34' 19 12 32 26 26 - - — 49 �28 18 Y '`- 3737 .' 120 mph 150 mph C 35 20 12 { 33' 27 r "'2 0. D 29 17 10 , 28 22 Notes: -Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in Inches forrpuiloui forces only.on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)includes additional factor of safety of-1.5 for lag pullout capacity 5.):Values based-on a.maximum module length of 70" 6.)Based on Risk Category If(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to i1..No.site specific engineering Is included in this table -www.ecofastensolarcom info@ecofastensolarcom 877-859-3947 9 Snow Load 31-4.0 psf Modules in Landscape Wind Speed Exposure1741. Roof Pitch<.6:12 7:12<Roof Pitch.<12:12 ASCE 7-05 ASCE 7-10 Category Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 59 '85 mph.. 1'10 mph, C 67 42 D 56 35 B 54 90.mph 115.mph C 61 38 D 51 32 B. 45 100 mph 125 mph C 51 32 D 43 27 B 57 36 110 mph 140 mph C 70 41 26 D 59 34 22 46- 46 B 50 31 120 mph 150 mph C 61 36 22, •47 47 D 51 30 . . 19, 49 40 40 Notes: ®Spacing Governed by.Snow Load 1.)Values in above table represent the.maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down-to meet appropriate rafter spacing 2.)-Maximum allowed spacing approved by EcoFasten Solar Is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module width of 40" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering Is Included In this table Snow Load 31-40 psf Wind S eed . .Exposure 2:12<Roof Pitch<-6:12 7:12<Roof Pitch<12:i2 ASCE 7-05 ASCE.7-10 CategoryZone.1 Zone.2 Zone 3 Zone 1 Zone 2 Zone 3 ".. 85 mph `; 110 mph, C 38•'.' ^,, r24'r. B 49- T30 90.mph 115 mph C 35 22 D 29 18 - - --- B- 49 100 mph , 125 mph C 29� 18 B 33 20 110 mph 140 mph C 40 23 14 D 34 19 12 26 26 - — -- - ---B- 49 28 1 g 120 mph 150 mph C 35 20 fit27. 27 D 29 17 10 a f "28 Notes: —Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only.on EcoFasten Solar standoff 2:)Maximum allowedspacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.),Based on Risk Category II(ASCE 7-10)structures less than.30 feet In height 7.)All adjustment factors are set to 1.No site specific engineering is included In,this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 10. a ` Snow Load 41-50 psf Modules in Landscape Wind..Speed Exposure 2:12<Roof Pitch<6:12 7:12<.Roof Pitch<12:12 ASCE 7-05 ASCE 7-10' Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2. Zone 3 B 59 - 85 mph 110'mph. C 42 D 56 35 . B 54 90 mph .115 mph. C 61 38 D 51 32 B 45 100 mph 125 mph C 51 32 D 43 27 B 57 36 110 mph 140 rnph C 41 26- D 59 34 22 46 46 B 50 31 120 mph 150 mph C 61 36 22 47 47 D 51 30 A 49 Q 40 Notes: Spacing Governed by Snow-Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, .however the designer must round down to meet appropriate rafter spacing 2.)Maximum allowed spacing approved by EcoFasten Solar is.72" 3.)Maximum allowed standoff capcity=547#(per testing results)- 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5:)Values based on a.maximum module width of 40" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering.is Included in this table Snow Load 41-50.psf Wind Speed Exposure 1 2:12<Roof.Pitch-<6:12 7:12<Roof-Pitch<12:12 ASCE 7=05 ASCE 7-10 Category Zone 1 Zone 2 - Zone 3 Zone 1 Zone 2 Zone 3 85 mph 110 mph C 38" 'i 24 B 30 90 mph 115.mph C 35 22 D 29' 18. 7 F.__� •_. 100 mph 125 mph C 29 18 f D 26 ; - 15 B 33 20 .110.mph 140 mph.. C 23 14 D 19 12 120 mph 150 mph C 35 20 12 D 29 17 10 k_. 22 22 Notes: .-Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing In Inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum,allowed spacing approved by EcoFasten Solar is 48" 3_)Maximum allowed'standof,,capcity=547#(par testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on•a maximum module length of 70" -6.)Based on Risk Category.It(ASCE 7-10)structures less than 30 feet In height 7.).AII adjustment factors are set to 1.No site specific engineering.is included In this table www.ecofastensolar.com- info@ecofastensoiar.com 877-859-3947 11- Snow Load.51-60.psf .Modules In Landscape Wind Speed Exposure 2:12<Roof Pitch.<6:12 7:12<Roof Pitch<12:l2 ASCE 7-05 ASCE 7-10. Catego Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone.3- B 85 mph. 110 mph C 42 D 35 B 54 90 mph 115 mph C 38 D 51 32. B 45 100 mph , 125.mph, C 51 32 D. 43 .27 B 36 110-mph 140 mph C 41 26 D 34 22 B 50 31 120 mph 150 mph C. .•'36 22 D. 51 30 - 19 Notes: .®Spacing Governed by Snow Load 1.)Values.in above table representthe maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)rMaximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag-pullout capacity 5.)Values based on a maxlmum.module width of 40" 6.)Based on Risk Category 11(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering Is Included In this table Snow Load 51-60 psf Wind.Speed- Exposure 2:12<Roof Pitch a6:12 7:12<Roof Pitch<12:12. ASCE-7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2. Zone 3 --- - - - - B 85 mph 110 mph ' C I 24 9 D 20 B 30 90 mph 115 mph C 22 -D 29 18 100 mph 125 mph C '1 29. 18 D` • 26 _ 15 - _ B 20 110 mph. 140 mph C 23 14 D 19 12 - - - �150 B120 mph mph C 20 12 D .29r - 17 T 1i 10,_ Notes: -Spacng.Governed by Snow.Load 1.)Values in above-table represent the maximum allowable spacing In Inches for pullout forces only on EcoFasten Solar standofl 2.)Maximum allowed.spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.),Includes additional factor of safety of 1.5 for lag pullout capacity 5:)Values based on a maximum module length of 70" .6.)Based.on Risk Category II(AS.CE 7-10)structures less than.30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering.is Included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 12 GrounDnGmFormaTlon The rail-free Rock-It System maybe used to mount and ground PV modules that comply with UL.1703,onlywhen that specific module has been evaluated for mounting and grounding,In compliance With the included installation Instructions. Note:Grounding lug must be visible to inspectors from-the entire perimeter of the PV-array. Multiple Use Grounding Pins Grounding pins within the Mid-Clamp are multiple use bonding/grounding devices.Modules will need to Wadjusted if th#Mid--Clamps are loosened to ensure there isnew"metA to pierce into upon retightening. Grounding Method Rock4t 4.0 Mount bonds N-S rows of.modules Rock-It 4.0 Coupling bonds EV rows of modules Rock-it Array Skirt bonds E-Walong'fhe entire array when installed One lilurndyCI_50-ITN ground lug Is required per PV array,limited to 300 modules placed In either portrait or landscape orientation, BonDnG ASSeMBL-YanD BOnDinG PaTH Sond Path Grounding Lug Integrated Bonding gmnne o3 RoCk-ItCcupling .10'Rock-it MOJM —Rock4,.May Skirt Bond Path Bond path Grounding Luga ip'Gromfing Lug EQUIamen-Groundtrz ,,VGroW ng (EGO, t0ourth Rock-Ir coupling so Rcck-It Coupling a Rock-it Mount, Rock-it Array Skirt 8 Rock4t Mount —Rock-It Array Skirt' vvww.ec:ofas:tensolar.corn lnfo@ecofastensolar.com 877-859-3947 13 THermaL EXPansion anD' BonDinG A thermal expansion gap is required per each continuous 40'length.of modules. — Bond-Path Grounding Lug Omit a coupling and leave a 2"gap in the Rock-It Array Skirt and also between / E2� r""�`$ -the-modules at that point. 8g= d m Rock-It Coupling ■ Rock-it Mount -Rock.-It Array skirt BracKeT spacinG Portrait Orientation- Landscape Orientation II � II f i , i. I , Maximum east/west bracket spacing is 48"OC. Max east/west bracket spacing is 72"OC. 32mm modules:Max east/west bracket spacing,Is 48"OC. Spacing may vary depending upon project specific structural requirements'i.e.:high snow and wind load areas may require lesser spacing E-W than'the maximum.. sTaG.Ge reD LaY.OUT canTLLever an.D oFFseT Staggered Mounting:Points. r ®Rock-It Mount Rock-it Coupling Cantilever: Maximum cantilever is 1/3 bracket spacing..For portrait orientation installations,check layout.prior to installing. •The array layout instructions in this Installation manual offer a general overview of layout. Periodically,.due to a variety of Offset:Offset from all roof edges depends on wind speed,snow factors(roof obstacles,shading,etc.)other layouts are required. loads,local fire and building codes per location www.ecofastensolar.com info@ecofastensolarcom 877-859-3947 -14 ROCK- IT SY STef'1'1 4.0 SySTem sPeclFicaTions Max No.of Panels 300 Modules per ground lug Materials -300 Series Stainless, 6000 Series Aluminum Max System Voltage 100oVDC Coating BlackAndodiza4(on/Mili Finish Gass A Fire Rating With UL1703Type 1 Rated Lug Specifications Bumdy CL50-ITN Ground Lug Modules,see note below. (UL Listing#KDER E9999) Leveling.Range. 3-4" Ground Wire 14 AWG-4 AWG Copper Per above Lug spec. Ground Wire Rock-it Slide Comp Range 3' Max Module Size 64.96"(1650mm)x Rockat Slide Tile 7' 39.05'(992mm)is 2"(50mni) :Min/Max Roof Slope '1/2:12/12:12 Max Downforce/UpIllt Rating 45 PSF Max Anchor Spacing(35mm/40mm) 72' Rock-It Mount Load Rating 547lbs with Single 5/16'Lag 3:0 Max Anchor Spacing(32mm) 46" Safety Factor Skirt BOX.QTY 6 units Slide Fastening Hole 5/16"dlameter Mount Box QTY 12 units Module Cantilever Maximum cantilever is 1/3 Rock It Slide Box QTY 50 units bracket spacing Coupling Box M. 12 units Warranty 20Year Material and WoFkman- ship Codes:National-Electric Code;ANSI/NFPA 70,NEC 250,NEC 690,IRC,IBC Standards:UL 2703:First Edition,UL 1703 'F,cOI'TS 5DIu ROCJhIT SYSTEM v�-;•:T'­.tv 'MPG ID CODE GGT-Q24016 unrmnnutto<• CONf0RM5T0UL 7/W CUNf0RM5T0 UC3703 lanunwvtnst.u.acti rya.. Ntu.u,ttrnwuutwos �!O .L�cn�um,vemcuoomn The EcoFasten Solar Rock-It System is a rooftop PV racking system consisting of 6000 Series Aluminum and 300 Series. Stainless.Steel components.The Rock-It System includes the rack components but does not include the PV panels, .Inverters or electrical-components.The PV modules to be used with Rock-It shall be certified under UL 1703.The system shall be used on steep slope roofs mounted over a Class Afire rated roofing material and attached'to the roof structure using:5/16".diameter,minimum 4"long 300 series Stainless Steel lag bolts with minimum thread embedment depth of 21/2"into the roof structure. Periodic re-inspection for loose components The system is subject.to re-inspection as required by the PV module manufacturer or.by the Authority.Having Jurisdiction:Re-inspectionVas required,should include evaluation of any loose components or loose fasteners.All .loose components and fasteners.should be secured.in accordance with these instructions.The system should also be .evaluated for any evidence of corrosion.Any corrosion should be removed.Any affected part should be cleaned or replaced in accordance with these instructions:. QrEcoFasten A Solar' - www.ecofastensolar com ihfo@ecofastensdiar.com 877-859-3947 15 FeaTures New and improved design North-South adjustability Fastest,.easlest to level system on the market Only one tool required.(1/2"deep well socket) • Integrated electrical bonding Vertical adjustment of Y-4" SIMPLE-only 4 components -Ev LuaTeD; -COI'1 paTIBLe MODULP_s MocMeMerthchrer Model Type(''x"used to module cimensims(mm) moduleDlmens:msQn)- Downward Pressure Upward Pressure Down-slopooeslg Madmumdamp Indicate variable test) Deslgn Lead(psf) Deslgnload(psfj .'Load(psf) SpadngQni Trim Solar TSM•xxx PXOS.OB- 1640 x 992 x 40. 64.95"x39.05"R1.57" 33.3. 93.3 20 72 Cenedlan Sdar. C5612-)aom 163@ x 922 x 4D 6448"48.60'457" 39.3 93.3 20. '72 CanedlenSdar CS6P-xxxP 1G38x9B2x40 64.5'W8.7'k1.5T' 33.3 No. 20 72. Jlnko Solar JKM)06rP.60 1650 x 992'x 40 6496'k39.05"x1.57" -30 30 20 .72 Jlnko Solar JKMxxxM-6O 1650 x 992 x 40 6496"fQ9.11W'457" - 30 30 .20 _ 72 Jlnko Solar J1(MxxxPP40 2650x992x40 64.96"x39.05'hd57" 30 30 20 72. Ake Solar JKMxxdMM-60 1650x992x40- 6496'*89.051'457" 30 30 .20 72 Ylngll Solar YL2)%P-29h 1650 x990 x40 %96"XS8.97"xL57" 30 30 20 72 LG Mcetronles. LG300N1GB3 1640 x 2000 x 35 6457149.37'x1.38" 90 30 20 72 LG Elcetronlcs L630DN1K-G4 1640 x 2000 x 40 64.57'39.3T.'x1.5T' 30 30 20 72 AdteeSolar. AGx1fxM/156.60S; .1640x992x40 645"x39.06'kLSB" so. 30 20 48 RECOM RCM-2xx-6M3. 1640x992x35' 6456"x39AS!'MS7" 30 .30 20 72- Sllfab R.A2xxP 1650x990xas 64.96"33837"XL49" 30' 30 20 72 Solaria PowerXr)wR4D( 262L x 1056 x 40 69.89"01.53"41.57" -30 30 20 48 Hernvha-Q Cells' O PnO 042xx 1670 x 1000 x 32-- 65.75'k39.3T'xL29" 30 3D. 20. 48 Hanwha--Q Cells' Q PRO 042xx 16M x 1000 x 32 65.75"x39.37'xL25" 30 30 20 72 Sunpreme' GxB-3xxT' 1670 x997x40- 65.75'k39.25"x1.57" 30 30 .20 .48 REC RE0xxx-6MB 1675x997x38 65.94"x39.25"4.51' 20- 20 20 72 REC REGxxx-GMB' 1675x997x30- 65.94"x39.251k1.5" 30 .30 ZO 48 SolarWorld SW xxx Mono Black 1675x961x33 65.95"x37.8"KL30" 20 20 20' 72 SSIarWodd -Sw xxxMono Black 1675 x961 x33 65.95"x37.8"xL30" 30 30 20 4e •Hanwha 0-Cells 32mm modules to be used with special order Rock-It System components.Call for details. yea � coFasten Solar www.ecofastensolarcom info@ecofastensolarcom 877-859-3947 1'6 r Cut Sheet - Rock-It-4.0-Mount 1. Installation to be completed In accordance with manufacturer's written specifications and installation instructions. 2.. See spec sheet or contact manufacturer for detailed material,finishes,,and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without.notice. O 3J 7in [80.54rnm] _ 2.50in 63.50mm I I I J I i I � � 1 2.02in 2.1.4in 2:34in [51.38mm]. [54.37mml- !L59.36mm -- -32mm — 35mm 40mm - -- -_..ALPINE r*&oF ten Solar'z`' 4741 W Polk Street.Ste.4 5L �S Phoenix,AZ 85043 Toll Free Phone 1.888.766.4273 Toll Free Phone-1.877-.859.3947 Matedal:.See-Spec Sheet Toll Free Fax 1:888.766M94 Toll Free-.Fax 1.888.766.9994 -- -- Scale: 1:2 6/28/2017. .ASG: - EFS: x Data Sheet Enphase Networking Enphase The Enphase IQ.Combiner 3'"' with Enphase . IQ Envoy' consolidates interconnection IQCombiner 3 equipment into a single enclosure and (X=1Q-AM1-240-3) streamlines PV and storage installations by providing.a consistent, pre-wired solution for residential applications. It offers up to four 2=pole input circuits and Eaton-BR series busbar assembly. Smart �li• Includes IQ Envoy for communication and control 1 ' L Flexible networking supports WI-Fi, Jl- 8 �� Ethernet,.or cellular Optional AC.receptacle available for PLC bridge Provides production metering and optional L e. consumption monitoring { Simple Reduced size.from previous combiner Centered mounting brackets support single s stud mounting. 1�. • Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in.breakers.(not included) 80 A total PV'or storage branch circuits Reliable • Durable NRTL-certified NEMA.type 3R enclosure Five-year warranty o UL listed LISTED '-� ENPHASE: To learn more about Enphase offerings,visit enphase.com u. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner.3 X-IQ=AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade PV . . production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan)- microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M%5-year data plan) .where there is adequate cellular service in the installation area.) Consumption Monitoring*CT CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%). Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers.. BRK-10A-2-240 Circuit breaker,2 pole,.10A,Eaton BR210 BRK-.15A-2-240 Circuit breaker,2 pole,154,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC 01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating .125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WxHxD) 49:5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21:06"(53.5 cm with mounting brackets). Weight 7.5 kg(16.5 Ibs) Ambient temperature range -400 C to+460 C(-400 to 1150 F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) Cellular Optional,CELLMODEM=01 (3G)or CELLMODEM-03(4G) or CELLMODEM-M1(4G based LTE-NI) (not included) COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 *Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings,visit enphase.com©2018 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. E N P H A S E. 2018-09-13 e� Y _ J `' ,-ter,,, 4) (�►i "r -` • 1 .t S '4. +e x ;Aj 2M'' ±� Z Y-4;f' jM* +. L4 V M �ti 1:r .' r• ' - Y i Z r. z'+ 'wrr.,•�Y c �<'.i 'r- *Yr"`�}'' tom``-"'' ar � ; +, x _ ��-}) o.S. ..r t f � •�.y.�**��5..', 1'''R it�r ,I .�'J �-�F.``r�t � J ... , , .' . . - ! yr L -.'. r cy�.'"r�,k+ +•♦ c.I��t �v� "T vF oYy r �r�t� - i r TABLE OF CONTENTS INSTALLATION INS'T C` I S Contents IMPORTANT SAFETY INSTRUCTIONS...................................................................................................................:....4 SAFETYWARNINGS $ CAUTIONS ..........................................................................................................................4 ELECTRICAL PRECAUTIONS............................................................................: MECHANICALPRECAUTIONS.................................................................................................................................. 5 PRODUCTINFORMATION.............................................................................................................................................. 6 OVERVIEW...................................................................................................................................................................... 6 PREP & PLACEMENT 7 ...................................................................................................................................................... REQUIREDTOOLS.......................................................................................................................................................7 PRODUCTPLACEMENT.............................................................................................................................................. 7 SPECIFICATIONS .......................................................................................................................................................... 11 MECHANICAL/ELECTRICAL................................................................................................................................... 11 TORQUERATINGS..................................................................................................................................................... 11 . WARRANTIES: Seller warrants to:Buyer that products and any services furnished hereunder will be free from defects in material,workmanship and title and will be of the kind and quality specified in Seller's written quotation.The foregoing shall ,apply only to failures to meet said warranties(excluding any defects in title)which appear within two years from the date of shipment hereunder: The conditions of any tests shall be mutually agreed upon and Seller shall be notified of, and may be represented at, all tests'that may be made.The warranties and remedies set forth herein are conditioned upon(a)proper storage, installation,, use and.maintenance, and conformance with any applicable recommendations of Seller and (b) Buyer promptly notifying Seller of any defects and, if required, promptly making the product available for correction. If any product of service fails to meet the foregoing warranties(except title), Seller shall thereupon-correct any such failure either at its option, (1)by repairing any defective or damaged part or parts of the products,or(ii)by making available, F.O.B. Seller's plant or other point of shipment, any necessary repaired or replacement parts.Where a failure cannot be corrected by Seller's reasonable efforts,the parties will negotiate an equitable adjustment in price. The preceding paragraph sets forth the exclusive remedies for claims (except as to title) based on defect in or failure of products or services;whether the claim is in contract, indemnity,warranty,tort(including Seller's negligence), strict liability or otherwise and however instituted. Upon the expiration of the warranty period, all such liability shall terminate and Buyer shall have a reasonable time,within thirty days.after the warranty period,to give written notice of any defects which appeared. during the warranty period. Except as set forth in Article 2, "Patents," the foregoing warranties are exclusive.and in lieu of all other .warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTYOF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. Seller does not warrant any products or services of others which Buyer has designated. www.soltection.com Soltection RJ-1 Installation Manual Page 3 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONSREAD ALL - PRIOR TO INSTALLATION NOTE: SAVE THESE INSTRUCTIONS This manual contains important instructions that shall be followed during installation and maintenance of the Soltection RJ-1 rooftop junction box with flashing. 1ALETHAL VOLTAGES ARE PRESENT DURING THE INSTALLATION, OPERATION AND SERVICE OF THIS EQUIPMENT. PROPER PRECAUTIONS MUST BETAKEN AT ALL TIMES TO ENSURE THE SAFETY OF THE SERVICE PERSONNEL. . SAFETY WARNINGS & CAUTIONS ■ Only qualified personnel or licensed electricians should install this product and the instructions herein are provided for those individual(s)only. ■ To reduce the risk of electric shock, injury, or death, all electrical wiring and connections must be performed by qualified personnel. ■ Lethal voltages are present during the installation, operation, and servicing of this equipment. Proper precautions must be taken at all times to ensure the safety of the service personnel. ■ Follow state and federal Occupational Safety and Health Administration (OSHA) guidelines and regulations when installing this product. ■ Utilize proper Personal Protective Equipment(PPE)as required per national and local regulations as well as for installation best practices. ■ Install this apparatus in accordance with ANSI/NFPA 70, National Electrical Code (NEC). Follow all national or local electrical codes. ■ Install, operate, and use this product in a manner consistent with the instructions provided. Failure to follow the procedures indicated may result in roof leaks, property damage, or consequential damage. www.soltection.com Soltection RJ-1 Installation Manual Page 4 r ELECTRICAL PRECAUTIONS ■ :Ensure all electrical conductors areat zero voltage potential before installing or servicing this unit. Never-break contact on.a-.circuit without using-the appropriate disconnect device. ■ Followestablished lockout and tagout procedures for all electrical conductors prior to servicing. ■ Beware.of.power lines in,the vicinity of.the roof,. where inadvertent contact may result in electrocution, personal injury,.or.death. When,disconnecting source.or.supply_circuits,.provide.sufficient time.as stated in the power.electronics manufacturer's instruction manual in.order to ensure.discharge of all conductors in,the circuit. Always verify the integrity and proper installation of the electrical components prior to energizing electrical circuits. ■ Non-metallic enclosures do not provide grounding means- between- conduit-connections. The use of grounding hubs and,jumper wires are required. ■ Grounding must be sized per NEC.requirements, and is the responsibility,of the installer. MECHANICAL PRECAUTIONS When drilling into an attic space,.ensure.that. electrical wires,, mechanical obstructions, or potential electrical hazards are removed from the vicinity and direction of the drill. Do not: install.-if the roof-.is wet, frosted, or covered by ice or snow. ■ If any part of this.product becomes-damaged, • remove and.destroy the entirety of the unit. Failure to do so may result.in, fire,,property damage, -personal injury; electrocution, or death. ■ Do not use the product-to anchor fall protection equipment. www.soltection.com Soltection RJ-1 Installation Manual . Page S. r , PRODUCT INFORMATION OVERVIEW ■ The Soltection RJA Residential Rooftop Junction Box is a flashed roof penetration designed to protect electrical .conductors entering the rooftop/attic. It is made of a high-strength UV-resistant and UV- stabilized-polymeric material. ■ The RJA enclosures comes fully equipped with a slotted DIN rail mounted inside the enclosure designed for mounting of DIN rail accessories, such as terminal blocks. ■ A four position ground bar is also-provided as a means to form a bond between the solar array mounted on the roof and the building. CORNER SCREWS MOLDED COVER PLASTIC SCREW FOR GROUND BAR AFFIXING DIN RAIL GROUND BAR 0 0 00 o MOLDED BASE DIN RAIL www.soitection.com Soltection RJ-1 Installation Manual Page 6 PREP & PLACEMENT REQUIRED TOOLS ✓ Shingle Ripper Bar ✓ Phillips Screwdriver ✓ Lumber Crayon ✓ Uni-Bit ✓ Hole Saw or Spade Bit ✓ Utility Knife ✓ Roofing-.Sealant RAFTER- PRODUCT PLACEMENT -- - - • Identify the location and placement.of the flashing on the roof as shown. The product may be mounted beneath'the array or = _ adjacent to the array. � t 6 * DO-NOT LOCATE THE PRODUCT DIRECTLY OVER A RAFTER TO ENSURE THE RAFTER DOES NOT INTERFERE WITH THE WIRING Remove template from packaging E NTRY I NTO TH E.ATTIC and use in Step.2 STEP 1 www.soltection.com Soltection RJ-1 Installation Manual Page 7 - 1 �kkt2�4��yt��;' a ��we"; +. • • • LOC �yI . �N Y�,y •� +c i. i- �Xi"z'� u ' CONDUIT ENTRY INTO ROOF h •� r t 1 Yf . Y • z RAISED AREA IN f l( MOLDE • M;�fi�;. trht� the�yy r, � •. }`, rAlo, 1,4 e �j 5�yL. hu♦ ���� 'M ._ �"4;��I�ll'��'p`'t+dt�""t' tr����} tE''"'Y rf}•� 1 s.• -�^�}4�zy �` ,r Fk ,it f..,u,���li'F.= a - eft• _: ���♦y '�A1 j.. � ��__A. 1�' .tea .c �' • .. Y • 1 t 1 �T. Remove RJ-1,flip it over,wipe it clean&apply Reinstall Unit. Use the two supplied Decking a bead of roofing sealant to the underside of the Screws to mount the flashing to the roof. flashing unit. Ensure that it's placed in the Torque to the specification indicated in the "Upside-down U"Shape to support engress specifications. Refer to Table T2(page 10)for water protection,AS SHOWN. the proper tightening torques. STEP 10 STEP 11 POPULATE RJ-1 • Populate the RJ-1 unit using the appropriate wire connectors, terminal ' blocks, or other necessary components. • Ensure that the components installed are rated for and are suitable for the intended purpose. • The RJA unit is provided with multiple standoffs which can accommodate accessories to be mounted. Step 11 . A Install the cover onto the top of the enclosure. Tighten 4 cover screws to the Torque value indicated in Table T3(see page 10) STEP 12 www.soltection.com Soltection RJ-1 Installation Manual Page 10 1 SPECIFICATIONS MECHANICAL/ ELECTRICAL ■ Product Certifications: UL508A Enclosure Rating:Type 4X ■ Attic Conduit Pass Through Connector.Size Range: 1/2"—1" ■ Max.Side Wall Conduit Size: 1" Maximum Current:-N/A Maximum Voltage: N/A.. ■ Ambient Operating Temperature: 45C to 75C TORQUE- RATINGS Table T1:Ground Bar Connection,Wire Range:#4 to#14, 4 Usable Connections moo o - 0 0 0 Wire Size Tightening Torque(lb- in)- -4-6 AWG -35 8 AWG' 30 10-14 AWG 25 Table T1 Table T2: Mounting Screw, Mounting to Decking, 2 Provided Ti htenin .Torque Ib4n : .15-20 Table T3: Tor ue Values, Cover/Lid Screws ,4 Provided, Captive Tightening Torque Ib-ln 11 www-.soltection.com Soltection RJ-1 Installation Manual Page-11 ■ TM Soltection- byvVn.ckier Soltection is a division of Vynckier Enclosure Systems, Inc. 271 McCarty Street Houston,TX 77029 1-866-227-0577 PLAN KEY SYSTEM INFORMATION CLIMATIC&GEOGRAPHIC DESIGN CRITERIA TABLE momentum PV-1 COVER PAGE MODULE HANWHA Q.PEAK DUO BLK-G5 315 R301.2(1) SOLAR PV-1.1 ATTACHMENT DETAIL INVERTER ENPHASE IQ7-60-2-US SPEED(MPH) 140 PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-2 ROOF LAYOUT RACKING ECOFASTEN ROCK-IT SYSTEM TOPOGRAPHIC EFFECTS B 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 PV-3 LAYOUT DETAIL SYSTEM SIZE (DC) 8.19 KW MOMENTUMSOLAR.COM PV-4 ELECTRICAL SPECIAL WIND REGION NO PROFESSIONAL LOCATION 28.2543000,-82.2246580 WIND BORNE DEBRIS ZONE 2 ENGINEERING PV-4.1 ELECTRICAL CONT. PV-4.2 EQUIPMENT LABELS GENERAL NOTES: SEISMIC DESIGN CATEGORY C THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS CLIMATE ZONE 2A FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, 6TH EDITION 2017 WIND EXPOSURE CATETORY B FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA BUILDING CODE, 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE, NEC 2014 AND ALL LOCAL CODES & ORDINANCES. ❑ ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. 1111111/",' INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND yt� . /y Iii HANWHA Q.PEAK DUO BLK-G5 315 NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. �'� p! • 315 WATT MODULE `� GEN F•. 6� X 3%4"X 6" ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT SEE DATASHE INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A P 7 PLUMBING PERMIT AND INSPECTION. ALL WORK$HAL,L CCII 0LY WITH PREVAILING -- K '' ';" ••: * G ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED CODES FLORIDA BUILDIN CODE, ' 1( )1f�1� w ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED NATIt�NAL ELECTRIC C®DE, p TE OF BILL OF MATERIALS AND THE CITY OF ZEPHYRHILLS '�'� • ST . ` ARCHITECTS ODULES 26 ANDNOT PR CLUDED F OM PERFORM NG ENGI EER NG SERVICES FOR IINTEGRAED GINEERING ORDINANCg MODULES INVERTERS 26 SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO BUILDINGS AND STRUCTURES. ��/111111� CLAMP ASSEMBLY 81 INVERTER PLACEMENT: COUPLING ASSEMBLY 26 REVIEW DATE DEC 6 2919 SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL CITY BONDING CUP 5 • LOCATED ON THE BACK SIDE OF EACH MODULE. SOLAR CONTRACTOR SKIRTS 6 PLAN£XM * CAMERON R CERTIFIED SOLAR CONTRACTOR UCENSE NUMBER:CVC57036 STRUCTURAL STATEMENT: 5728 MAIOR BL MOMENTUTE 307,ORLANDO FL.32819 ENPHASE COMBINER BOX 1SOLAR CUSTOMER INFORMATION EATON 60A FUSIBLE AC THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY DISCONNECT 1 THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER AUSTIN GONZALEZ-M541029 SIZES &DIMENSIONS CONFORM TO 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE 6694 WAGON TRAIL STREET 40A FUSES 2 FBC, Residential 2017 ZEPHYRHILLS,FL 33541 MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE (813)323-5906 125A UNE TAPS 2 REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. PV SYSTEM INFORMATION TABLE R301 .2.1 .3 SYSTEM 512E(DC):8.19 KW WIND SPEED CONVERSIONSa B6 315 S:HANWMAQPEAKDUO 26 INVERTERS:ENPHASE IQ7-60-2-US VL,it 110 115 120 130 140 150 160 170 180 190 200 PROJECT INPORMATION Vasd 85 89 93 101 108 116 124 132 139 147 155 INITIAL DATE:12/27/2019 DESIGNER:GCP For SI: 1 mile per hour = 0.447 m/s. REV: DATE: DESIGNER: REV: DATE: DESIGNER: a. Linear interpolation is permitted. COVER PAGE PV- 1 SEE ATTACHMENT SCHEDULE FOR MAXIMUM CANTILEVER "ECOFASTBI"ROC(-IT ATAQ#EIIT SYSEM momentum 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS,GABLE AND HIP ROOFS COUPLING CLAMP& 'ECOFWWI"ROCK-IP 9WA MOOUE SOLAR CONSIDERED FROM AN ANGLE OF MIN.9.5°( )TO MAX.45°(i)NOT TO EXCEED ATTACHMENT �g EJ0.5N�ROff 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THE 'ECWASW SKRT FLMM ,AND PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR RNE MANUFACTURER. RAFTS 325 HIGH STREET,METUCHEN,NJ 08840 2. SPAN TABLES ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE SOLAR MODULEJL (IAF7� (732)902-6224 MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THE MOMENTUMSOLAR.COM MANUFACTURER. PROFESSIONAL 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 ENGINEERING 4. ATTACHMENTS ARE MANUFACTURED BY ECOFASTEN SOLAR, PHOENIX,ARIZONA. GUTTE AND ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS. MINIMUM 5"SPACING TO GUTTER ROCK-IT TO RAFTER ATTACHMENT SPACING SCHEDULE ECOFASTEN SOLAR ROCK-IT 4.0 MOUNTING DETAIL *ALL MODULES TO BE INSTALLED IN LANDSCAPE ORIENTATION ECOFASTEN SOLAR ROCK-IT 4.0 RAIL-LESS MOUNTING SYSTEM ALL CQ C*JIR 9441 BE AS MAMIFACflE BY"ECOFASO SCUR"Mm INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE MTAl1ED N SST jIN(E Im MN PRN18! SRoANFIS. ONLY IN WIND ZONES OF 15OMPH&UP. CLAMP ATTACHMENTS ATTACHMENT DETAIL FOR SLOPED DESIGNROOF ROOFZONEI ROOF ZONE 2&3 WIND MAX.SPAN/MAX. MAX.SPAN/MAX. COMP. SHINGLE ROOF ` I:I L 1 I I i,, SPEED CANTILEVER CANTILEVER (MPH) (INCHES) (INCHES) SEE ATTACHMENT SCHEDULE . w 16" w FOR MAXIMUM CANTILEVER 'ECWASIEM ROC(-IT IGEN F'• • 1i 125 MAX. 32 O.C./12"MAX. ATAC}I�IT SY51EY 48 O.C.O.C / - 130 48"O.C./16 MAX. 32"O.C./12"MAX. I "EOOFASTQP SIDLE QW 9QAR M=E 140 48"O.C./16"MAX. 24"O.C./10"MAX. COUPLING oEa YOINT 1/2 UIG 150 48"O.C./16"MAX. 24"O.C./8"MAX. CLAMP& BOLTS TO RAFIER EfERNi6 MI „ a 7k ATTACHMENT PLYMM OINK,AMi ro �i Y,.K. •: i 160 48"O.C./12"MAX. 22"O.C./8"MAX. T iiiRAFNR �•� 1131 J 170 48"O.C./12"MAX. 19"O.C./8"MAX. Q • SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY ITABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED RIS SOLAR MODULEI II I ft '/ss�ONAL TOPOGRAPHIC EFFECTS B,C,&D AND ROOF WIND ZONES 1,2,&3. ROOF ZONES 2&3 �!Ij 11 III ARE WITHIN 48"OF ANY OUTER EDGE,HIP,RIDGE,OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. GUTTER GUTTER ® (2 1 ® ® ALL GOLPQIENTS 9WL BE AS MAMWACIM1®BY"EW AS UI SOLAR"NO NSTAIIEB N SIAICT COIBuMIII NM MIIIRFXR S PRt= SPBIi1CAAplS w I GUTTE SOLAR CONTRACTOR m w w ATTACHMENT DETAIL FOR ® LOW-SLOPED ROOF CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR RIDGE RIDGE MINIMUM 5"SPACING TO GUTTER 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 0 ®® ECOFASTEN SOLAR ROCK-IT 4.0 MOUNTING DETAIL *E fl(W-IT CUSTOMER INFORMATION y/,p ECOFASTEN SOLAR ROCK-IT 4.0 RAIL-LESS MOUNTING SYSTEM ATACIMT SY$IEM AUSTIN GONZALEZ-M541029 INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE "MA"E-0-5 6694 WAGON TRAIL STREET 0 m 0 CLAMP ATTACHMENTS ATTAOIUIT NO RASING /I ZEPHYRHILLS,FL 33541 8 JIQEI5 FAS B R5 TO DEC( EJE6>If16 ROff (813)323-5906 (3 0 GUTTER ® GUTTER ® "W "SKRT o�lt PV SYSTEM INFORMATION / / SYSTEM SIZE(DC):8.19 KW 26 MODULES:HANWHA Q.PEAK DUO ROOF WIND ZONES AS PER IRC R301.2(7) MAXIMUM SOLAR ARRAY ELEVATION:4.25" BLK-GS 315 ROOF ZONES 2&3 ARE 48°FROM OUTER ROOF EDGES, :48"26 INVERTERS:ENPHASE Na7-6O-2-US RIDGES,HIPS,RAKES,AND GUTTER EDGES FOR STRUCTURES MAXIMUM CLAMP ATTACHMENT SPACING BELOW 30'-0"MEAN ROOF HT. COUPLING CLAM PROJECTINFORNATION INITIAL DATE:IIJ27/2019 DESIGNER:GCP SOLID BLOCKING REV: DATE: DESIGNER: BETWEEN JOISTS ALL CCIFWM SNAIL BE AS WXFACM F( 4 9W AID NSTNIED N SBUCT CppIWICE NM MANIWAC1 S PRI(RO SEU1CAfl4S. REV: DATE: DESIGNER: i+)W Zm W ATTACHMENT DETAIL FOR ROOFS ATTACHMENT DETAIL AREA WHERE RAFTERS NOT AVAILABLE PV- 1 . 1 r i SCALE: 1/8" = 1'-O" ROOF PANEL COUNT TILT AZIMUTH SHADING R1 26 25° 183 99% momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING DRIVEWAY /',iiTiFIRE SETBACK (36" VENTILATION, i� $T E F Q/ RIDGE 36" ROOF ACCESS) 'iO.t' •'• �LORtO v`�`� (TYP) ',,,sS�ONAt 111111 U Z 0 0 0 0 U.' D! o 0 0 0 0 0 z SOLAR CONTRACTOR O CAMERON l�L 0 0 ❑ 0 0 CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR 5728 MAXM BLVD. SUITE 307,ORLANDO FL.32819 0 0 0 0 0 0 SYMBOL LEGEND CUSTOMER INFORMATION I AUSTIN GONZALEZ-MS41029 GROUND ACCESS Rl I MSP MAIN SERVICE PANEL CHIMNEY 6694 WAGON TRAIL STREET (TYP) • ❑ ❑ 0 0 ❑ ❑ ZEPHYRHILLS,FL 33541 SP SUB-PANEL z SKYLIGHT 813 323-5906 GUTTER PV SYSTEM INFORMATION UTILITY METER z VENT SYSTEM SIZE(DC):8.19 KW 11 OM AC 26 MODULES:HANWHA Q.PEAK DUO UDC DISC CB D AC DISCONNECT O PIPE VENT BLK-G5 315 ELECTRICAL EQUIPMENT 26 INVERTERS:ENPHASE IQ7-60-2-US UDC UTILITY DISCONNECT ® FAN LC LOAD CENTER D/ SATELLITE DISH PROJECT INFORMATION INITIAL DATE:11/27/2019 DESIGNER:GCP N3R NEMA 3R BOX W/ENVOY-S • FIRE SETBACKS AS PER 6TH EDITION 2017 FFPC REV: DATE: DESIGNER: CB COMBINER BOX • MIN 3'x3'GROUND ACCESS REV: DATE: DESIGNER: POINT NOTE: ROOF LAYOUT 0 MODULE � PITCH DIRECRON 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE. 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. WIND PRESSURE ZONE LINES.REFER TO -2 1 i i PV-2.2 FOR ADDITIONAL INFO R1 -ARRAY 1 LAYOUTTDETAIL SCALE: 3/16" 1 0 momentum TILT: 25" SOLAR AZIMUTH: 183° SHADING: 99% PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING 11 I II 11 I1 F0" I I I I I I i I Eli i ID I IT\\\\N I I I I P I I q I I ❑ I I I ❑ ❑ • 1 I II III ICI I 11 I I I I I 1 I ________________________ I I 6 d a a I (a I � I SOLAR CONTRACTOR I I ( I CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR ❑ ❑ ❑ ❑ ❑ ❑ ( 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 CUSTOMER INFORMATION �` I ! iliiiiliii till AUSTIN GONZALEZ-M541029 6694 WAGON TRAIL STREET L 0'-6" ZEPHYRHILLS,FL 33541 (813)323-5906 PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.19 KW 26 MODULES:HANWHA Q.PEAK DUO BLK-G5 315 17'-9" 33'-5" 10'-0° 26 INVERTERS:ENPHASE IQ7-60-2-US PRO3ECTINPORMATION INITIAL DATE:11/27/2019 DESIGNER:G0A REV: DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL PV-3 PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS MODULE MAKE HANWHA INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE MODEL Q.PEAK DUO MODEL IQ7-60-2-US WIRE RUN VmP ImP R L(FT) VO % VO WIRE SIZE momentum BLK-G5 315 SOLAR MAX POWER 315W MAX OUTPUT POWER 240W BRANCH TO 3-BOX 240.00 16 1.98 105.33 6.674 2.78% 12 AWG OPEN DC VOLTAGE 48V PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR OPEN CIRCUIT VOLTAGE 40.29V J-BOX TO LOAD 325 HIGH STREET,METUCHEN,NJ 08840 CENTER 240.00 26 1.24 50.00 3.224 1.34% 10 AWG (732)902-6224 MPP VOLTAGE 33.46V NOMINAL AC VOLTAGE 240V MOMENTUMSOLAR.COM LOAD CENTER TO AC SHORT CIRCUIT CURRENT 9.89A MAX AC CURRENT 1A DISCONNECT 240.00 32.5 0.778 3.00 0.152 0.06% 08 AWG PROFESSIONAL CEC INVERTER EFFICIENCY 97% AC DISCONNECT TO ENGINEERING MPP CURRENT 9.41A 240.00 32.5 0.491 10.00 0.319 0.13% 06 AWG NUMBER OF MODULES 26 NUMBER OF INVERTERS 26 INTERCONNECTION UL1703 COMPLIANT YES UL1703 COMPLIANT YES SUB PANEL # OF MODULES PV BREAKER THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2017 PER BRANCH BREAKER SIZE FLORIDA BUILDING CODE AND THE 2014 NATIONAL ELECTRICAL CODE UP TO 16 20A �IIIII► /i,' 26 HANWHA Q.PEAK DUO BLK-G5 315 315W MODULES PAIRED WITH s .A� //#i, 26 ENPHASE IQ7-60-2-US MICRO-INVERTERS S • %GEN .. * BRANCH CIRCUIT A - 16 MICRO-INVERTERS + H I EXISTING SQUARE D A . * E BRANCH CIRCUIT B UTILITY SUB PANEL 240 V �.A 1 Lar ..• ii,. 10 MICRO4NVERTERS METER 000 ST •�► III i tORID GRID i ••••• � S• ENPHASE 80A //iP*0NAU + - + - AC COMBINER SOLAR CIRCUIT BOX DISCONNECTING MEANS____ iJ • • • ij EATON 60A FUSIBLE AC r v DISCONNECT NE SIDE 8 HOT TAP SOLAR CONTRACTOR 8 A11 150 CERTIFIED SOLAR CONTRACTOR �UCENSE NUMBER:CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 ROOF J 1 OA BREAKER J T POWER CUSTOMER INFORMATION JUNCTION (ENVOY) 40A FUSES I GROUND 1 BOX 2A-B 20A BREAKER(A)3 4 EXISTING i50A A6694 WAGON TRAIL STREET TERMINATION CAP 20A BREAKER(B) EXTERIOR MAIN INSTALLED ON DISCONNECT ZEPHYRHILLS,FL 33541 END OF CABLE 150A BREAKER (813)323-5906 PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.19 KW 26 MODULES:HANWHA Q.PEAK DUO BLK-G5 315 Wire Temp. Wire Temp. Conduit Derated Inverter NOC NEC Design Ground Ground Wire 26 INVERTERS:ENPHASE IQ7-60-2-US Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty (A) Correction Current(A) Size Type 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 16 1 1.25 20.00 12 AWG Trunk Cable PROJECT INFORMATION 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 16 1 1.25 20.00 08 AWG THWN-2 INITIAL DATE:11/27/2019 DESIGNER:GCP REV: DATE: DESIGNER: 2B 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 10 1 1.25 12.50 08 AWG THWN-2 REV: DATE: DESIGNER: 3 1" PVC 3+G 08 AWG THWN-2 75°C 50 0.96 1 48.00 26 1 1.25 32.50 08 AWG THWN-2 THREE LINE DIAGRAM 4 1" PVC 3 06 AWG THWN-2 75°C 65 0.96 1 62.40 26 1 1.25 32.50 THWN-2 NOTE: LETTER"G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. PV-4 ELECTRICAL NOTES: 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 1. ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER momentum BASED ON ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE NEC ARTICLE 300.6(C)(1)AND ARTICLE 310.8(D). SOLAR COEFFICIENTS. 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO(NEC 690.46-250.120 LOCATIONS PER NEC ARTICLE 310.8(C). 325 HIGH STREET,METUCHEN,N7 08840 PARAGRAPH C).THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING#6 BARE COPPER WIRE OR#8 THWN-2 COPPER 25. TOTAL AREA OF ALL CONDUCTORS,SPLICES,AND TAPS INSTALLED AT ANY CROSS MOMENTUMSOLAR.COM WIRE. SECTION OF THE WIRING DOES NOT EXCEED 75%OF THE CROSS SECTIONAL AREA OF PROFESSIONAL THE SPACE.NEC 312.8(2). ENGINEERING 3. THIS SYSTEM COMPLIES WITH NEC 2014 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE CONDUIT,COMBINER,JUNCTION BOX,DISCONNECT.AND COMPLIES WITH 690.6-NO DC LARGEST BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN.IN ADDITION,VOLTAGE DROP CALCULATIONS FROM PANELS TO THE 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 690.56(C).AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS.690.6. 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C 11111///� 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC MODULES WILL COMPLY \ p 1W 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM WITH 250.64. �� �i EQUIPMENT DATASHEET �� SC { 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SYSTEM 690.17,690.6. '• ° LOCAL AND NATIONAL CODE REQUIREMENTS. I 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(D)(3), Ns4�(';; Ii L : 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER 705.12(D)(2)(3)(B),705.12(A)AS PERMITTED BY 230.86(6) :'0 � I • �` INSTRUCTIONS %'A '•• ST *• E F 32. ALL WARNING SIGN(S)OR LABEL(S)SHALL COMPLY WITH 2014 NEC ARTICLE 110.21(B). ���o��•'•... 0R%aP-' O" 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D) LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD.LABELS SHALL BE 'j/7/S .. �� 11. PER NEC 690.17,PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE ' S •a PERMANENTLY AFFIXED TO THE EQUIPMENT,AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION>SIGN SHALL READ*WARNING-ELECTRIC SHOCK 33. PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM HAZARD-DO NOT TOUCH TERMINALS-OR EQUIVALENT. THAT IS SEPARATED BY ENCLOSURES,WALLS, PARTITIONS,CEILINGS,OR FLOORS. TABLE 1: 12. PER NEC 705.10,PROVIDE A PERMANENT PLAQUE OR DIRECTORY VOLTAGE CONDUCTOR CONDUCTOR SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT MAKE MODEL RATING RANGE MAIN RANGE TAP SOLAR CONTRACTOR SERVICE ENTRANCE. CAMERON CHRISTENSEN ILSCO IPC 4006 600 V 4/0-4 AWG 6-14 AWG CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 M SOLAR 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64 6728 MAJOR BLVD.M�SUITE 307,ORLANDO FL.32819 ILSCO IPC 4020 600 V 4/0-2 AWG 2/0-6 AWG CUSTOMER INFORMATION 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB-CIRCUIT BRANCHES IS ACCEPTABLE. AUSTIN GONZALEZ-MS41029 INSTRUCTIONS FOR LINE TAPS 6694 WAGON TRAIL STREET 15. ALL CONDUCTORS MUST BE COPPER. ZEPHYRHILLS,FL 33541 FIGURE 1: 813 323-5906 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER 1. ADJUST THE CONNECTOR NUT TO PV SYSTEM INFORMATION SUITABLE LOCATION NEC 250.24(C). 2. PUT THE BRANCH WIRE INTO THE CAP SYSTEM SIZE(DC) 8.19 KW 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A SHEATH FULLY 26 MODULES:HANWHA Q.PEAK DUO GROUNDING ELECTRODE SYSTEM PER 250.54(D). 3. INSERT THE MAIN WIRE,IF THERE ARE BLK-GS 315 TWO LAYS OF INSULATED LAY IN THE MAIN CABLE,SHOULD STRIP A CERTAIN 26 INVERTERS:ENPHASE tQ7-6t}-2-US 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA LENGTH OF THE FIRST INSULATED LAY DC. FROM INSERTED END PROJECT INFORMATION 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION 4. TURN THE NUT BY HAND,AND FIX THE INITIAL DATE:11/27/2019 DESIGNER:CO PIERCING CONNECTORS MAKE,MODEL,AND RATING OF CONNECTOR IN SUITABLE LOCATION. (IPC). REV: DATE: DESIGNER: INTERCONNECTION CAN BE SEEN ON TABLE I BELOW. 5. SCREW THE NUT WITH THE SLEEVE SPANNER. REV: DATE: DESIGNER: 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND ELECTRICAL CONT. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC DROPPED DOWN SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. PV-4■ 1 ALL WARNING SIGN(S)OR LABEL(S)SHALL COMPLY WITH 2014 NEC ARTICLE 110.21(B).LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD.LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT,AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. TAG LABEL QUANTITY LOCATION NOTE EXAMPLES momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR MAIN SERVICE ' 1 POINT OF INTERCONNECTION .;- ,� 325 HIGH STREET,METUCHEN,NJ 08840 PANEL A (732)902-6224 MOMENTUMSOLAR.COM _ PROFESSIONAL ENGINEERING 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DC COMBINER IF USED 1 AT ANY JUNCTION BOX OR DC ♦�` -.GEN �✓ O 1 JUNCTION BOX ♦ ••� IJ COMBINER IF USED n 1 OF EACH AT FUSED AC O D DISCONNECT 1 AC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON DISCONNECT LABEL SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 0 CUSTOMER INFORMATION AUSTIN GONZALEZ-M541029 6694 WAGON TRAIL STREET 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN ZEPHYRH{LL5,FL 33541 0 • PANEL DISCONNECT PANEL 813 323-5906 PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.19 KW ( 26 MODULES:HANWHA Q.PEAK DUO A BLK-G5 315 26 INVERTERS:ENPHASE IQ7-60-2-US 1 UTILITY METER 1 AT UTILITY METER PROJECT INFORMATION INITIAL DATE:11/21/2019 DESIGNER:GCP REV: DATE: DESIGNER: SI w•" REV: DATE: DESIGNER: 1 AT EVERY SEPARATION BY MULTIPLE AC CONDUITS ENCLOSURES/WALLS/ EQUIPMENT LABELS PARTITIONS/CEILINGS/FLOORS OR NO MORE THAN 10' PV 4. 2