Loading...
HomeMy WebLinkAbout19-22011 CITY OF ZEPHYRHILLS / 5335-8th Street (813)780-0020 22011 ELECTRICAL PERMIT / PERMIT INFORMATION LOCATION INFORMATION Permit#:22011 Issued: 11/07/2019 Address: 35942 SADDLE PALM WAY Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 55,120.00 Total Fees: 480.00 Subdivision: SILVERADO Amount Paid: 480.00 Date Paid: 11/07/2019 Parcel Number: 05-26-21-0080-00500-0030 CONTRACTOR INFORMATION OWNER INFORMATION Name: SOLAR BEAR LLC Name: OZOROWSKY, MICHAEL & LAUREN LEA Addr: 6101 JOHNS RD STE 8 Address: 35942 SADDLE PALM WAY TAMPA, FL 33634 ZEPHYRHILLS, FL 33541 Phone: (727)218-9407 Lic: Phone: 813-810-2647 Work Desc: INSTALL ROOF MOUNT SOLAR SYSTEM APPLICATION FEES ELECTRICAL FEE 480.00 INSPECTIONSAEQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER - FINAL I REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. pats""� 110_&a_ AW49%7 ONTRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER = 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permtttin 727 940,3256 -rrrrr-rrr - �-r�- rnEX Owner's Name OZOROWSKY MICHAEL&LAUREN LEA Owner Phone Number 8138102647 Owner's Address 35942 SADDLE PALM WAY,ZEPHYRHILLS,FL 33541 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 35942 SADDLE PALM WAY ZEPHYRHILLS FL 33541 LOT# SUBDIVISION SILVERADO RANCH PARCEL ID# 05-26-21-0080-00500-0030 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT 0 SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR = COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 17.1 KW BUILDING SIZE SO FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 55,120 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ( I =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# ELECTRICIAN R __n `�v COMPANY SOLAR BEAR LLC SIGNATURE REGISTERED N J FEE CURREN Y/N Address 6101 JOHNS RD STE B TAMPA FL 33634 License# I EC13009020 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN LILN Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREI, I Y/N Address License# IIIIIIIIIIIIIIIIIIIIIIt11111111111t11111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonnwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directlons: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authodzing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the -contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended Contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR� � Subscribed and sworn to(or affirmed)before me this Subscribed and s om to(oraffi )'befdre:me}this by 6y- Who is/are personally known to me or hasihave produced Who is/are personally known to me or has/have pro-duced DL as identification. DL as iden ication. Notary Public Notary Public Commission No. Comm'sio No. Name of Notary typed,printed or stamped Name of N ti...• 1ACGUELINE BJGES Commission#GG 276457 Expires December 12,2022 '••9,„V„R•' Bonded Th.Troy Fain Insurance 560-385-7619 o Y r City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: . Date Received: 0 h/y Site: 3.5 /. Permit°Type: -Ths�j1 PU01 ^O n 4[F/l. Approved w/no comments Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. CT, 3 1 2019 Kalvin i er—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) DocuSign Envelope ID:E1AE5246-D808-4515-9344-354033D91785 All SOLAR REAR SOLAR BEAR LLC 6101 Johns Road,Suite 8,Tampa,FL 33634 Your Solar Solutions Provider (727)471-7442 W W W.OURSOLARBEAR.COM EC13009020 SOLAR HOME IMPROVEMENT AGREEMENT DATE: CUSTOMER NAME(hereinafter,the"Customer") 10/1/2019 Michael ozorowsky ADDRESS:35942 Saddle Palm Way CITY,STATE,ZIP: zephyrhills, FL 33541 HOME PHONE NUMBER: WORK PHONE NUMBER: MOBILE PHONE NUMBER: 813-810-2647 EMAIL:michaelozorowsky@hotmail.com This Solar Home Improvement Agreement(this"Agreement")is between Solar Bear LLC("Solar Bear","we"or"Contractor")and you("Customer")for the sale and installation of the solar system described below(the"Project"or the"System")at your home the"Property"or your"Home").The Parties agree as follows: 1. Was a full years usage of the customers electric bills provided? YES NO xa 2. If no,does the customer understand we can not guarantee a 95%-105%of the previous YES NO years usage. El 3. Does the customer understand the ITC 30%TAX CREDIT is based on their taxable income?YES FX NO ❑ IF YOU DO NOT PAY INCOME TAXES YOU DO NOT GET ATAX CREDIT PROPOSED SYSTEM SIZE PURCHASED SYSTEM SIZE (Based on 12 months previous usage) 17.10 KW 26,419 KWH ANNUALLY 17.10 KW 26,419 KWH ANNUALLY CONTRACT PRICE AND TERMS OF PAYMENTS. I understand,that if I cancel, I will be held financially 55,120 responsible for the cost of the permit and any work that Total System Cost: may have taken place. D=usig�b: FX] Check Here If Any Portion of the project Sign M.Iud 0-, ebrewsLy Total System Cost is Financed. 10/i/Z019 If checked,the Customer will receive a separate Date agreement from the Finance Provider outlying their terms and conditions. AMOUNT PAID TODAY:$ 0 BALANCE REMAINING:$ 55,120 • An explanation of the Recommended System Size has been explained to me and I have a copy `An explanation of the Federal Investment Tax Credit(ITC) has been explained to me and I have a copy INITIAL NOTICE OF RIGHT TO CANCEL THIS IS A LEGAL BINDING AGREEMENT AND YOU MAY ONLY CANCEL THIS AGREEMENT PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS AGREEMENT.TO CANCEL THIS AGREEMENT,PLEASE SEETHE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT.THANK YOU FOR YOUR ALLOWING US TO SERVE YOUI , Customer Signature: 1 Wd d 0-Irt L4 Date: 10/1/2019 Customer Signature: Date: °° °° 10/1/2019 Representative: E-11-byww F; Date: ij 1 DIRECTORY OF PAGES Saddle Palm Way SCOPE OF WORK P-125540 PV-1 PROJECT SUMMARY I 'O s°aGiP THIS PROJECT INVOLVES THE INSTALLATION OF PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE PV-2 SINGLE-LINE DIAGRAM N a/hob - RACKED USING A PRE ENGINEERED RACKING SYSTEM.THE 00N PV3 SAFETY LABELS 'ay RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE ki MODULE DATASHEET LOCAL UTILITY USING MEANS AND METHODS CONSISTENT BAY AREA WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND Pupr.,;ss,„1 X OPTIMIZER DATASHEET T, PERMITTING JURISDICTION. Z DISCONNECT DATASHEET aPA a INVERTER DATASHEET ° THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF W O_ DESCRIBING THE DESIGN OF PROPOSED PV SYSTEM WITH MOUNTING SYSTEM ENGINEERING LETTER ay ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS.THE DOCUMENT N � }' UL 2703 GROUND AND BONDING CERTIFICATION SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR >- }Y _ FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. C/) i7a THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS F) PROJECT DETAILS aai LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL 0� 3 eQ APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE W _l PROPERTY OWNER MICHAEL OZOROWSKY W � , INTERPRETED IN A WAY THAT OVERRIDES THEM. a� . yY U Q CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL PROPERTY ADDRESS 35942 SADDLE PALM WAY, ay CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. O O Z ZEPHYRHILLS,FL33541 US a. N W W 1 Cl ZONING RESIDENTIAL Map&-ta=19 SYSTEM DETAILS : LC) ci USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING NEW GRID-INTERACTIVE Q W w Q CLASSIFICATION GROUP GROUP R3 PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO (/) Q Cn ( ) BATTERY STORAGE _ PV-1 SCALE:TUTS CV AHJ _ _ _ OC RATING OF SYSTEM 17,10OW 0 V UTILITY COMPANY PROGRESS ENERGY FLORIDA INC v '01 - W CA AC RATING OF SYSTEM 15,20OW ELECTRICAL CODE 2014 NEC(NFPA 70) - AC OUTPUT CURRENT 64.OA Ch FIRECODE 2015 NFPA1 .', - ss INVERTER(S) 2 X SOLAR EDGE SE760OH-US Richlend' '''- �"" MODULE SILFAB SLA300M CD CONTRACTOR INFORMATION � z >O T 1)STRINGOFI4(INV#1 1 COMPANY BAY AREA PROJECT SOLUTIONS -:g ARRAYWIRING ((1 STRING OF IS((1NV#13 �. "� O �` vs - €2;STRINGS UCENSE NUMBER - �® •.� I'' /,%1- ,.•�\ - 2512 BAY FIELD CT,HOLIDAY,FL —, f '�� - ADDRESS 34691 /� TO 0 r zepnyrnilis INTERCONNECTION DETAILS -�.�= N rn m© ® North PHONE NUMBER (727)543-Mi _ aslrn � � POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION .;I C),,��//��JJ jj I - "M �'.;- PER NEC 705.12(A) — CONTRACTOR > ���yyy UTILITYSERVICE 120/240V 1� SIGNATURE ,'� O � - p�I tiB3"Zephyrhills Upper 1" `�V V.fant["' ,. "Hi)Isborpa9H -� ® .M UU ff 0Skydlve City/Z-Help na `Pre&ervr.' 1 �= nyrnUs SITE DETAILS ❑pry 1CT�•+��'; �•� ASHRAE EXTREME LOW 1°C(34°F) F"lVsll:+\.•1T\�\ ,Mapdatn®2019G-gle ASHRAE2%HIGH 34°C(93°F) St"MM' ANY zCLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) 1•, "` WIND SPEED 160 MPH(ASCE7-10) D DA D:1011611 156477-1 PYIA SCAM: •S RISK CATEGORY II CREATOR: r - WIND EXPOSURE REVIEWER: p�Tq CATEGORY RGROUND SNOW LOAD R EVIS IONS 9"m - G) PV-1 f PVMODULE __ , jPVMODULE MODULES GENERAL ELECTRICAL NOTES P-125540 - { I OPTIMIZER I• I OPTIMIZER REF. Ctt. MA(EANDMWEL PMAI( PTC IBC IMP VOC VMP TEMP.WEF OF VOC FUSERARNG PMI6T 57 sILRAa sLwProM Soon 27on ena 911u 34ry Dzev -0.Izwc I.vcl 20q UTILITY HAS 24HR UNRESTRICTED ACCESS TO ALL I I 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE - PM3D57 INVERTERS SERVICE ENTRANCE. 30OW I _I 300W 1 I 300W qEF.att MAXEANDMMEL VOLT GR=0 OCPDRAn RATBO MALT' MAX INPUT MAXINPUi CECWEGHIED Isla 14N 141N 14w 1'0/JEx MRRENT WRRENi vMTPGE EFRclslcr 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. I I I I UNGRWNDE BTRING IS siWNc srwxc II-z z saaR®cESEewHLs zaw aaA 7,EOOAI 3zw zpw /wv esaw CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS ' D 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND A A A POWER OPTIMIZERS ARTICLE 310.8(D). /a.r REF. Ott. MWfl RATm INRITIVWFR MAXWTPUTCURRENT MAXINPUT ISC MAXDCVWTeGE WEIGNIED EFFICIENCY - I 1 I- PG1L7 57 —AETGN3P3at Darn USA a DA IBv seals CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE PASS-THRU BOXESAND COMBINERS 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE REF. Ott. MVIEANDMODfl i 31 O.B RATED CUfwFNi MA%RATEDYOLTAGE C I 1 1 3 .G1Q 2 G-ETEDCWAW TO- XGREWIV. 3M &P7AC7600VDC ( ). Cc W �-JUNCTION BOX JUNCTION BOX PANT I I I GENHYCGFNALCOMBNEROREWIM I20DA 140VAC Lu L_ co W JBI L__, DISCONNECTS OCPDS GROUNDING NOTES MAXRATED >- r— r RE.DY LW EAND MOOEL RA ED WRRET OLTAGE REF. OTY MTEDWRRENT M/O MTAGE I 2 I 2 sW1 I EA--NRe QOEWIV laoa z4wAD WI2 z 4aA zlovAc 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE � p Q �' Ff-z z mA zlwx REQUIREMENTS OF NEC ARTICLES 250&690 INVERTER I �IN.SD0W SYSTEM SUMMARY NOTES PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS � W CM I T,eoow I 2 T,6Dow NV I INV.z USING MODULE LUGS OR RACKING INTEGRATED W 1 I STRINGI STRING] SiWNGI S11UNG2 QOPTIMIZFAS RiGVIDERAPDSHUl00AN FUNCTIONALtt AEWIFID BY NEC 69012 � rs o oWER 4suW 4 o0n lawn Azoow 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. O Li L.� — L� — lPTO POWER 4.1b 1RIBN 3,T1INW 3,7BbrY THE SPECIFIED OPTNW!ERCAN SE SUBSTITUTED WITH AP400,P405,P370,P505.OR P3e0 ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED d C/3 MI IDTMAXOUTPUTMRRBIT USA ISA USA iSA 7HUE° MJZMSWAN'EANIWWV LTAG£WNp NWDEENWGa1roACWA'ODATE USING UL-LISTED LAY-IN LUGS. N W J r" r� IFM WiPUTVMTAGERANGEOFTHEMWULEATTHEOESIGN IE.mERANREB,HAVEA N MIIEIiS IN SEW ES IS f1 I/ I/ I MA+cINPuiMRReIrRAnIVGTHaTISaswETHEMA+cMTnrrcuRRENroFTHE INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS p = I I OMIN,Y SIWNGV TAGE CURRENTI-TAGE 10W 10DV 4WV dOW MODULE ANDAMAXFONE01NWTiNATISPBOJE THE MIm NNET CIITPUr CFTHE I I rDPPaanxocuRRENr n.0 msA fpsA lass MODULE BEEN EVALUATED FOR COMPLIANCE WITH UL2703 � Cl I rs cPOWER a70Dn e,/ms 3 "GROUNDING AND BONDING"WHEN USED WITH PROPOSED O � Q I ✓` I ✓` YPTCPOWER 7,842N 7,671W UNGRWNDEDSYSTEM DC CONDUCTORS SHALL BELWgTCMEOISFWLONS DC (,/� __-- 4 --- 4 accUITRENT Daa 32A PVMODULE. N = ®rosI7DYESIwLBE RED REDIaxD DC NEGanvEsw4L BEDLacX(OR �____ _____________� acCOMBI R ACPON__MT 7.UVW 7,60ow MARXEDBIACO 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED p � II cB2 c61 PANT ERATEDeDPCAER°°nvr 7•san 7•°°a" FOR THEIR PURPOSE W J p� W rL YSTC POaER 17.10M ALL METAL ENCLOSURES,RACEWAYS,CABLESAND EXPOSED NONWRRENTLAARYING aDA 40A YPTCPOW'FR I5Af3W MEAL PAM OF EMPMEMSIWL SEGROUNp®TOEARTHASREDARE3 SY NEC IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVEA �' W M N 1 ADMITRENr ea �z5D4(B)ANDPPRnxoFlscuTn C 9045 THE RIDUN TmouEm1RODES STEMSs VERIFIABLE GROUNDING ELECTRODE,IT IS THE p Q 1 SNALI BESI7EDACCORDINGT0 NEC 69015 THEGROUNDIM1G HECTRODESYSTEbI SNAll 5 I S POPoWFPWER 15.aT)N ADHERETOW047(B)ANDMIWiHEDCGIiWN01NGElECRi00EBH41.BE6i2FD CONTRACTOR'S RESPONSIBILITY TO INSTALL U 2 EMIEDAC FVAERWIPUT 15.076W ACCORDINGTOz50.166 SUPPLEMENTAL GROUNDING ELECTRODE. BDq PVSYBIEMDISCONECT MADDMONALA YGRQINDINGEIEi;TROOESH BEINSTALLMINACWRDMCE AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC) sw1— vnTH NEcsEcnoNs aspszallozSDsI UNLEssTxEARRAv sIRUC1HELG suTPHETO 6 SHALL BE A MINIMUM SIZE#BAWG WHEN INSULATED,#6AWG r-----------� 1W BERVEABAGR INTEGRAL THTHEARAS.O NEC PROM ]502,1HELWDSQN®BY THE ARRAYIS INTEGAALWITN 111EARPAY,g37/E%TEARES EASnNGW1WNG IF BARE WIRE. e ELECTRODE ISLO TFDWTHIN6 .ASERNECSEn7IWM47(0) EQUIPMENT GROUNDING CONDUCTORS SHALL BESIZED RDDAMSPWDDDAMCB) 00 MAX DCVXTAGEOFAWUYFTXEOBY THE IN�TTELATMREGw+DLEssoF 7 ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF I ®TEaPEUTURETHEMAXDCVWTAMOFTHEMMULEATI•CISE1wECTm7oBE/zry #10AWG WHEN NOT EXPOSED TODAMAGE,AND 96AWG ' I (I•c-zs•L7x�12v�c.Bsbsv-42Tv1 ) ' , I FILOAD. SHALL BE USED WHEN EXPOSED TO DAMAGE r I wESSI3 DISCONNECT SIWLBEAVIUWE IDISI ETYPEDISWN,&T1Wns GROUNDINGANDBONDINGCONDUCTORS,IFINSULATED, 1 \ O ACCQBIf4EANDLWKAEE BYTFIE UnLIry.THE OISWNNEGTBNALLBE LOGTFD ) - ------ - ---- - tMTHIN 1aFTCFunuttMETaT. 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF _l POINT-040NNECTIWISON HESUPPLYSIDEOFSIZZAMDISWNNECTATA #4AWGORLARGER IJTILffY MEIEI2 ®LOCALLYAPPROYED WNNECnON POINT.USINGLOGILYAPPROYEOMETHODS PNO ( 11 KWHR 2401120V 1m,3W HARDWARE,IN CCMPLIANCEWITH NEC 70512(A), I11 I 1; GEC CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS IrnGl DONgICTM —T/ren,v OCMMCTdL01ND OCFO EGO IENm.CORK FlLL WM. MAX DIW+ENT fMSE OFMTEO iE1W. ASIP.B TENM 7'` ) ('� •' c0xwrtludE FAcrM FARM aRRExT Dls><I Aw Alm. iFLP MnxD TEam.runxD \\, � 1 ��1. I /°•I' IOAwOWW1RF, 0AW0&AE, ''1.)I) ) t 1 COPPER iFIEAd Na NM �R OTf pFq 10 ,54 fA15A SS1 DOA IYO 0M 1 1 1°A ; —.1— 4 NIA 10-11 -2 DTlmo Oe 'm ISIN MAII71A APO 3 3 ° NEAR xA xa °A 07f Sq ,D A A 5 w DsmA YD 1D / SINGLE'IL'tJFP)AGRAM eAwa Wm.z taAwG W WNa, 1 1 Ix»Nv+ rpu uxc 4 lu mPPm DaeF31•q Da 37A mA ssc azW 1Pc sM s 1 ��z 1•— 1 1., °"�.� DF(F q 10 61A w es. 912A ]rc Nw PROJECT ID:125540 e f ro° z 1 eMXz Aw""""n 0°9FMq 111 VIA .1 9sA 91a ]rc w DATE: 10116119 CREATED BY: SDT CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV-2 SCALE: NTS /�) Wi3DOODMM S fD MIATFDFMWEPUPPOSEMOESORENOA WUMNMANFOSEOPHOTOYOMMGPOWTI]SYSTEMWRXExou0N0ETNLTODEMo"s1M1EOQIPIIIWLE Au �_L A— SAND REMun INTBEDGweInTMa NOMNrlEnE.ueoDPMUAwasnnn:wRFG=MAMAxuvAclumnw Si EMMSXUONSWTAUERa1AUI"sTAUAueoulPuxrN ACW W.WfE VAM WHYFALNRER dSlALLAnM VANVAIS NOnIINOW id°WCUIkM SNdhOffEINiENRETEDd A WAYTNAi OVERPo0E5MEd°fRULTONSd WWViAONREAd°iADAnONMWVIIS DCRACEWAYS POINT-OF-INTERCONNECTION OR AT MAIN EACH DMCE WHERE ENERGIZED, LABELING NOTES r-125540 10 SEE NOTE N0.5(DC RACEWAYS) 02 O UNGROUNDED CIRCUITS MAY BE EXPOSED O SERVICE DISCONNECT(MSP) DURING SERVICE.(JBI,J32,11,12) 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC - - 1 AND 2015 NFPA1 WILL REINSTALLED AS REQUIRED. CAUTION 1' : I WARNING I LABELS,WARNING(S)AND MARKING SHALL COMPLY JB1-TRANSITION BOX POWER TO THIS BUILDING IS ALSO FROM ROOF ELECTRIC SHOCK HAZARD.THE DC WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, MODEL NOT SPECIFIED • p p • ••• • MOUNTED SOLAR ARRAY WITH SAFETY •CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM. WARNING,AND CAUTION SIGNS USED THE STANDARD BABY AREA DISCONNECTS AS SHOWN ARE UNGROUNDED AND MAY BE ENERGIZED., 2 HEADER COLORS,LABEHEADL THE ANDSTANDARD SAFETY ALERT O O SYMBOL ON EACH LABEL THE ANSI STANDARD REQUIRESAHEADING THAT ISAT LEAST5 TALLER NEC 69031(G)(3)AND IFC 605.N.1 NEC 69056(B) NEC 690.35(F) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). JB2-TRANSITION BOX EACH DISCONNECTING MEANS FOR uj MODEL NOT SPECIFIED)SPECIFIED O PHOTOVOLTAIC EQUIPMENT(JB1,JB2,11.12) O DC DISCONNECT(11,12) O AC SOLAR DISCONNECT(SW7) APERMANENT PLAQUE OR DIRECTORY SHALL BE U) } INSTALLED PROVIDING THE LOCATION OF THE SERVICE _ 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC > Q SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME I WARNING'1. RATED MPP cURRENTr20.0A LOCATION IN ACCORDANCE WITH NEC 690.56(B), c/) 'ELECTRIC SHOCK HAZARD.DO NOT TOUCH• RATED MPP VOLTAGE:400V 11-INVERTER TERMINALS.TERMINALS ON BOTH LINEAND MAX SYSTEM VOLTAGE 4&1V PHOTOVOLTAIC AC DISCONNECT WHERE THE INVERTERS ARE REMOTELY LOCATED w FROM EACH OTHER A DIRECTORY IN SHALL BE W --L SOLAR EDGE SE7600H-US) LOAD SIDES MAY BE ENERGIZED IN THE OPEN M iCIRCUIT CURRENT:30,CA INSTALLED AT EACH DC PHOTOVOLTAIC SYSTEM O U Q POSITION.` DISCONNECTING MEANS,AT EACH AC DISCONNECTING 0 0 Z �- O40 05 NEC 690.17(E) NEC69053 NEC 690.13(B) 4 MEANS,AND AT THE MAIN SERVICE DISCONNECTING a W W MEANS SHOWING THE LOCATION OF ALL AC AND DC N CIL Q ANY AC ELECTRICAL PANEL THAT IS FED BY PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IN a Q 12-INVERTER O AC DISCONNECT(SW1) OB SEE NOTE NO.6(SW1) O BOTH THE UTILITY AND THE PHOTOVOLTAIC - THE BUILDING,IN ACCORDANCE WITH NEC 690.4(H). J co0 (SOLAR EDGE sE760oH-us SYSTEM(SW7,PANT,MSP) LABEL(S)WITH MARKING,'WARNING PHOTOVOLTAIC W LL Q POWER SOURCE,'SHALL BE LOCATED AT EVERY 10 Q_a U) O 04 O ',� FEET OF EACH DC RACEWAY AND WITHIN ONE FOOTOF N = MAXIMUM AC OPERATING CURRENT:64.OA • • • p •• e I WARNING 1 5 EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE 0 V � MAXIMUM AC OPERATING VOLTAGE:240V ••! •• DUAL POWER SOURCE.SECOND SOURCE IS AND BELOW ALL PENETRATIONS OF ROOF/CEILJNG LL SWi-DISCONNECT PHOTOVOLTAIC SYSTEM. ASSEMBLIES,WALLS AND BARRIERS.THE LABEL SHALL u') (EAHAVE 3/8'TALL LETTERS AND BE REFLECTIVE WITH 17 TON DG223NR8 M WHITE TEXT ON A RED BACKGROUND 0 O O O O NEC 69054 NEC 690.56(C)AND IFC605.11.1 NEC 705.12(D)(3) LABEL(S)WITH MARKING,'PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN;SHALL BE LOCATED 10 AC DISCONNECT(C811N PAN1,C821N PANT) 11 AC COMBINER PANEL(PAN1) (� AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE v DISCONNECT THE LABEL SHALL HAVE 3/8'TALL PAN1-AC AGGREGATION PANEL _ LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON ` MODEL NOT SPECIFIED RED BACKGROUND IWARNINGI , O10 11 MAXIMUM AC OPERATING CC10.lT:32.OA THIS EQUIPMENT FED BY MULTIPLE SOURCES. ,\ MAXIMUM ACOPERATING VOLTAGE,240V TOTAL RATING OF ALL OVERCURRENT DEVICES,, •�)�' 'j 1 EXCLUDING MAIN OVERCURRENT DEVICE SHALL MSP-MAIN SERVICE PANEL 'NOT EXCEED AMPACITY OF BUSBAR.- O �X O NEC 690.54 NEC 705.12(D)(2)(3)(C) SAFE�TYj'W:,1�1�ELS DOC ID:125540-156477-1 DATE:10116119 CREATOR: REVIEWER: REVISIONS PU P ' Test Conditions STC NOR Module Power(Pmax) wp 300- 227 Maximum power voltage Npmax) V 32.8 29.5 °* , Maximum Power current(IPma%) A 9.16 7 69 f L - SLM 3 °`• :,• 1 1 / Open clrcultvoltage Noc) V 39.85 36.9 I � .. Short dreuit current(Isc) A 9.71 7.96 Module efficiency % 18.4 17.3 SOLAR- Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance000) Wp -O/t5 ® ® ® O ® ® Measuremem rcnJJl°m:5TC 1000 W/niE•AM 15•Tempentwe iS Y•NOCfa00 W/m••AM 1.5•Measure eM unsertanrys35e .• Sw sunulatorraLbraxon relermce m°Julesh°m FrauMoler letlmaEleafral duran may.aryby:saeana P°wergal.s. Temperature Coefficient Isc %/K 0A3 Temperature Coefficient Vac %/K -030 Temperature Coefficient Pmax %/K -038 ------ NOR(3 2°q °C 45 ® 9h INDUSTRY LEADING WARRANTY opera0ngtem erasure C -401+85 All our products include an industry weight(t 1 kg) k + 19 leading25-year product workmanship Module Module ns(HxLxD;tlmm)•• mm •i650x990x38Y and 30-year performance warranty. DimensioMaximum surface load(wind/snow)• N/m° 2400 Pa upward/5400 Pa downward - - ® 0 0, Hall Impact resistance 025 mm at 83 km/h 35+YEARS OF SOLAR INNOVATION cells 60-SI monoc ystalllne-4 or 5 busbar-156.75 x 156.75 mm' ® Leveraging over 35+years of worldwide Glass 3.2 mm high transmittance,tempered,antireflective coating A A experience in the solar industry,Silfab Backsheet Multilaveredyester-based is dedicated to superior manufacturing Frame - Anodized Al(Stack) processes and innovations such as Bypass diodes 3 diodes-45V/12A IP67/IP68 Blfaclal and Back Contact technologies, Cables and connectors(See lmtallaUon manual) 120D mm a 5.7 mm(4 mm2),MC4 com atible to ensure our partners have the latest in - ' • •• f solar Innovation. Module product workmanship warranty 30years NORTH AMERICAN QUALITY a97%endof"year a Linear power performance guarantee a 90%end of 12m year R ® Sllfab is the largest and most automated ae2%end o'---ar solar manufacturer in North America. a gD%end of 30°`year - utilizing premium quality materials and Strict quality Control management t0 deliver ' ULC ORD C1703,UL 1703,IEC 61215,IEC 61730-1 and IEC 61730.2 Certified. 5 the highest efficiency,premium qualityPV Product FSEC and CEC listed.IEC 62716 Ammonia Corrosion,IEC 61701:2011 £€ Salt Mist Corrosion Certified e -_ modules 10045 made in North America. _ UL Fire Rae_ng:�e2(type 1 on regues0 Factory IS09001:2015 'Please refer to the Safety and Installation Manual for a ing speci0 n ee12 year extendable m 25 years subJect to registrationa andd c conditions outlined under warranty at wvrw.sllfabsolar,com. A Warning:Read the Installation and User Manual before handling Installing and operating modules. �� ,�� Third-party generated pan files from �i Modules Per Pallet:26 -• VV Fraunhofer-Institute for Solar Energy n_11 to Pallets Per Truck:36 ^°J r,' o• , 5ysteZe,ar valiable for downloatl at (� u,J :Modules Per Truck:93fi Yandnp°OI American A&Cclmplhiree�The .Depar - - vwv,dlfabsolar.com/downloads •% $ r I�the Continental USA witina mww.x�� 3R n days, LIGHT . . quality. 5 to 54000a. framee RESISTANT .• ' ^ Sllfab Solar Inc yy$ 1-1 "\\ 240 county 3 C��S eypark Drive East R �..w Mississauga ON L5T2Y3 Canada eritireirlignufaqturfingSl�fab Tel xm, P. info@sllrabsolar.com I-silfabsolar.com °�^•-•+^m •°+m•• j]©® Sllrab5olarinc. g00 Cornwall Ave Bellingham WA 98225 USA Tel.1 360.5694733 ® Power Optimizer For North America Power Optimizer P320/P340/P370/P400/P405/P505 0. For North America P320/P340/P370/P400/P405/P505nodules) d modules) modules) d.les) m INPUT Rated input DC sbwes4' 320 340 370 4m 405 505 W Abobte MaK—input wrage 48 60 80 126'A 83m we (wc at bwes[IemperuNm) MPPT operating Range 8-48 8-60 8-80 125-105 12.5-83 we Max'na,m slmn c'rcurt am:m 0� 11 10.1 14 Add 1'' T Maimum DC Inprrt Current 13.75 12.63 175 Adc v Maximum EMcenq• 99,5 % We-ghted Effie-cy 98,8 98.6 % Qervoltage Category 6 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Curtent 15 Adc Maxlrtum Output whage EO 85 w< OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety atp"wlbtge per 1:0.1 we Power CM--r t' STANDARD COMPLIANCE EMC FCC Pa,0 Class 8,JEC61000 b-2,IEC61000-6-3 sa4.y IEC62109a(da 0-1-4,6 L1741 ROHS h INSTALLATION SPECIFICATIONS M1fanrtlum Allowed SYstem lead Ve, wraps Canpatible inverters All SolarEdgd Sir I Phase and Three Pnase'mer Dimensons(W.Lv 10 128 x 152,2815 K 5.97.1.1 12BK 152x36/ 128,152x50/ 128x 152 x59/ min/'n 5 x5.9]v 1?2 1v5.97x1.96 5x 597 x 2,12 Wnght Oncludmg cables) 630/1.4 711117 845/1.9 106/2.3 gr/Ib Input Connector MC4m outP t Wire Type/Connector Double Insulated.MC4 Output Wm Length 0.95/3.0 12/3.9 m/h Input W re LengN 0161052 m/h Operating TemperaNre Range -40-.85/-40--165 'C PV power optimization at the module-level Protection Rating IP68/NENIA6P Reldt Humid'ty 0-100 % a'Petty Sw Paver W Me rraduk.MWule of up m•5%pvwr mleranm e4awM NEC X1I requxes max made ud4v9e be nos more Man s., / Specifically designed to work with SolarEdge / Fast installation with a single bolt wrpMer inn^.�mr ins,mea:r s¢nunsaaaega inverters / Next generation maintenance with module- / Up to 25%more energy level monitoring Minimum Stnng Length P�32.0,P'340'""' 8 10 18 / Superior efficiency(99.5%) / Meets NEC requirements for arc fault gbweropt'mae") Pins/Pws 6 8 14 protection(AFCI)and Photovoltaic Rapid Mavnwm Sv gtdr th zs zs s� / Mitigates all types of module mismatch losses, Shutdown System(PVRSS) rypwer opum':ers) sroo(600owm w from manufacturing tolerance to partial M1lminumPo ,r Smng SE]6NUS-SE11400- 5250 6mv4 msom w shading / Module-level voltage shutdown for installer Parallel"""of 04ferent Ldngmt US) and firefighter safety o o.-atom / Flexible system design for maximum space �•Fpree,a,lm mry pny mmmamn reeem 6 ]mwwsaaeb tin gep,mnne:/aeraehmlev:pman:mg"v wl utilization nq inn win mreMn gpopm iers dpo n.340ry3NEC pdM main mgmremen¢ ry vaegewl sM 30V For SE144KUS/5E43]KLS'his a'bx4minsvll upm6.5gOW l be show regvremens per smngwren Jzv'ngs areknn W m Inrcrmr13samgz per unn for SE431KU5)am wren Me mammum power biherence besvrcen Me nnngs's up m I,gggW For SE3pKU5/SEl3 JKUS/SE66 WIS/SE1pdKU5:h¢albved m nsull up m 15,ggpW per sMng M'en 1 smogs are KonneasC m Me inverter(3 smngz per unn br SE666KU5/SESWKUS) a^d when Me mawmpm ww..axerenm berwean me:mops c pP ro zoopw solaredge.com solar 4. ® • CC ROHS U®T*N Product compliance:No Data Powering Business Worldwide pe.eaton.com @ 2016 Eaton.All rights reserved. Genera( Duty Cartridge Fuse Safety Switch DG223NRB UPC:7821 1 31 44252 Dimensions: •Height:7 IN •Length:6.42 IN •Width:8.82 IN Weight:g LB Notes:Maximum hp ratings apply only when dual element fuses are used.3-Phase hp rating shown is a grounded B phase rating,UL listed. Warranties: • Eaton Selling Policy 25-000,one(1)year from the date of installation of the Product or eighteen(18)months from the date of shipment of the Product,whichever occurs first. Specifications: •Type:General Duty/Cartridge Fuse •Amperage Rating:100A •Enclosure:NEMA 3R •Enclosure Material:Painted galvanized steel •Fuse Class Provision:Class H fuses •Fuse Configuration:Fusible with neutral •Number Of Poles:Two-pole •Number Of Wires:Three-wire •Product Category:General Duty Safety Switch •Voltage Rating:240V Supporting documents: •Eatons Volume 2-Commercial Distribution •Eaton Specification Sheet-DG223NRB Certifications: • UL Listed Af Single Phase Inverter With HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/ Single Phase Inverter Z SE760OH-US/SE1000OH-US/SE1140OH-US 00 .Ft with HD-Wave Technology m O1edTAPCUbwe 9WC' 5� @ r� @ 33W @ 208V SOW @ 208V I 10000 @ 208V Maximum AC Weser Output 3000 38W p 240V SOW 6000 @ 240V 7(�0 i0W0 -M @ 240V VA for North America T 33Wp08V SOW@20BV , 0000@208V N AC Wprt`hlb tge Min:om- NAU ,x. , , We SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ a11-24D AC Output Wte Wlbge Min-Nom-Max , Vac SE760OH-US/SE1000OH-US/SE1140OH-US ACRe08-229) T■ � ■ Mui.uerxy(NomNa9 59.3-fi0-60.5^' flz Maximum Continuous Qrtput Current @240V 125 16 1 21 1 25 32 42 ITS A nuo eoIarnr7-,,,;o.,,,,. Maximum us Output © Current @2(MV2WV 16 - 24 - - 48.5 A - GFDI Threshold 1 A Ln U[Nry Mo—nag,Islandiag to 1 solo y; `ItD.b O Protecton,County Conrgurable Ks Thresholds IJ INPUT I' C) `U Maximum DC Power 0240V 4650 59W 1 7750 9300 11800 155W 17650 W Maximum DC Power@208V 51W 1 7750 - 155W W Tr...ha er-'less.Ungrounded yes !r ++! Maximum IapR M,kp 480 Ydc -++1 Nominal DC Input Vakzoe 380 eW We Maximum Input Currem @240V•+ BS "S I 13.5 16.5 20 27 30.5 Mc `O O O J� Me.—Input Current 92MV. - 9 - 13s - 27 Adc Max.lnpl,tsnorta,alteur.em 4s Me p� 9' Reeene-Polanty Protector 1'es Ground-Fault lmla6on Deteaon 6M.5--y 1 Maximum Inverter Efficenry 1 99 99.2 % i CEC Weghted ElEc-cy 99 998950 85 @ 99 @ 240V % M Nghttime Power Cnnsumpton <2.5 W ADDITIONAL FEATURES Supported Communicatbn Interfaces RS485,Ethernet ZbEiee(optanal),Cellular(optbnaR Revenue Grade Data,ANSI C12.20 Option,P Rapid Shutdown.NEC 2014 and Automats Rapd Shutdown upon AC Gad DOmnnect Optimized installation with HD-Wave technology 2W760.12 STANDARD COMPLIANCE Safety UL1741.UL1741 SA,UL1699B.CSA C22.2,Canadian AFCI acmrd,ng to TLI.M-07 f Specifically designed to work with f Extremely small cold connemon Sbadards4 — IEEE1547.Rde 21.Ru'e 14(HR power optimizers Emmons L FCC Pan 15 Class B f Record-breaking efficiency f Built-in module-level monitoring INSTALLATION SPECIFICATIONS AC W"t COMuit Size/AWG 3/4'm.n­­/14-6AWG 3/4'nan—m/144 AWG Ra o f Fixed voltage inverter for longer strings f Outdoor and indoor installation DC Input C..u,t S../rl of Stings/ 3/4'--na/1.2 anN,/146 AWG 3/4'mnm m/1.3 cr,ngs/14.6 AWG AWG Range D:menn—w[h Safely Swoh 17.7x14.61r6.B/450x370x174 21.3x14.6,7.3/540x 370,185 In/ f Integrated arc fault protection and rapid shutdown for f Optional:Revenue grade data,ANSI C12.20 (R.W.D) mrn NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) Weghtw Safe),S—h 22/1D 25.1/11.4 1 262/11.9 388/17.6 lb/kg Noise <25 1 <50 dBA f UL1741 SA certified,for CPUC Rule 21 grid Cooeng Nawml C. wn compliance Ope,anng Temperaw,e Range -W to.140/-25 m•W"(-40'F/-40'C opton)N T Protectbn Rating NEMA 0 pnverter with Safety Sw.h) s°laredge.eom solar ......—meal SE'.H US00NNU4 ROHS Customer: Michael Ozorowsky Address: 505 Washita Stone Dr Ruskin, FL 33570 RESIDENTIAL 6 COMMERCIAL EFFICIENCIES System size: 17.10 kW Yr 1 Production: 28,637 kWh Designer: Blake Ambrester Site Assessment Date: October 14th, 2019 t,',cs I ygg 'KNOW rif ,e#3R } it- -- I - If ir Jim -fi t . It a .. a_ powered by aurora INSTR#2019202574 OR BK 10013 PG 1823 Page 1 of 1 11/26/2019 02:44 PM Rcpt:2112204 Rec:10.00 DS:0.DO IT:0.DO Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller PREPARED BY:SOLAR BEAR LLC 6101 JOHNS RD STE B TAMPA FL 33634 Pan Ndmbt► 22011 ParoellD NwW "-- :Y6t2-i-o6s6"66-E o--096 " NOTICE OF COMMENCEMENT S111116 of Florida COMOIy of PASCO TIC UNMEIMM Weby SW AMA UW hnpwvemenla Ka be made It torah real prolift,ud In 8=WV a aft S*Wm 7f3.13 of W Ralda Saban,dM l,-f 'g tdmndw b paNOW h fhb kVM OF COIWEWEUMT. SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 075 BLOCK 5 LOT 3 3I wed Uaq Adamz �S l _-_-lrc(!Yy► �2 hyrl►.i15 ��L—335 __ ._..___ W-W disa"on a1 tBp10W mft rNSTAI:L SOLAR 9 Or11r hltWMIU n at Lalsiea Warntgo K da Loves con two for me k*vv a) Maldadtraes b)obma&W add "of tee Iltnplo ONbtlder(Il dM M lhan Dift UN above► NIA h kaeroat m pnnpaigc T0091.-,- -- 3)Name and address: NOR MAN PURKEV-SOIAR GEM U.6 elm JOHNS RD STE a TwpA FL 330 4 b)Tow"%-- 727.H40 3�8 — _.. ..-..__.__ Fax NW(Optlanaq 0 appi Dafmbiv,a WWOf MO M boil m tfidied;_ a)Nana and ad&= NIA b)Te)WowNo- tj Amoorg d BmLtS.Landw a)Name and aO&= N/A T Pesaro rdtldn the State d flahla desk by Owner opt sin ram adha dowmertsmay Gi sorvee as piovw—blt 5ediai 713.13(t)(a)7.,laor(da Sf3twz a)Name road adds¢ NIA b)Tdepboe Na: Fax No-(op*�. 6a In 3d�tlon ho biunY ar henetl,Ortnrdaiprnets wu _ at to waft a vw of lbe U mors Wo as podded In Seoaon 713.13(1)(b),pews Stablt-4 b)Pbaa N nbs o1 Pwea1 a GMbdwWjW byOww- fL ExpYadke►da13 d aOtlee d eamratia�emt(da taptAon daL may oot be bolus Bo em pialoo of eoirauaon and liow p 1p tl►a mMsdvbdNbel tan added mMuadaleratdamle�te-e1): 20 IIM ?��NNMfB�AN1fNAYrBdiB YADE�OWN131 AFTER M ENARA7KAI OF 7-*--WW OF COI1111111801318IT— T JIBE? ( witapERPAYNIMMWMERCHAPTER71%PART{,SECTION713.13,Ft.ORMSTAIOM AND CAN REWTNVOW 1 ;y PAY=rMCE POR NWROYEIM111 M TOUR PROPERTY.A NO110E OF COMENCE NEiR HIM BE WORDED AND POSTED ON I F 7HE JOB STE BEFORE THE RRST WP=oK.IF YOU MIUM M OBTMf FIAUNC M CONSLLT WffH YOM LOW OR AM i ATMFMEY BEFORE 0019 8=0 WORKOR RECORMW YOUR NOTICE OF COWAINCE11M. ` d paduy,l de�e flat t have nwad tivi birspdip note of Wnsogomu and ttaa ft Usk difed tbarab seine to lht LaMo1J bead. F OZorrl 1 7irima9tt btomso<rletadmmrdpedbat= afhle I-i _ daya 2D - F1ta11*KahTlsi ❑ f4odMlO r ( °Datwryabrtara.eoa,t>�.rawsmmtidl ) Ty"dlO OL Nolwyftvn ' Padre A IS GW MARIN .'{��rt WCO►q,IL5510NaGG31131/ 1:�'3• +")�5}1 Ei0'IRES MrcA 1e.2029 "f .P'.,,',`,. o1LW,N1do9P�Ta '