Loading...
HomeMy WebLinkAbout19-22017 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22017 BUILDING PERMIT PERMIT]N FORMATION LOCATION INFORMATION Permit Number: 22017 Address: 5416 8TH ST HISTORIC Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-12000-0130 Improv. Cost: 700.00 OWNER INFORMATION Date Issued: 11/06/2019 Name: FIORINO, GIOVANNA Total Fees: 97.50 Address: 5416 8THST -HISTORIC Amount Paid: 97.50 ZEPHYRHILLS, FL. 33542 Date Paid: 11/06/2019 Phone: (585)478-2442 Work Desc: GARAGE DOOR REPLACE 8 X 7 CONTRACTORS APPLICATION FEES JAMES L FRANK DOOR SERVICE BUILDING FEE 67.50 CONTRACTOR CERTIFICATE 30.00 L Ins ections Required FOOTER 2ND ROUGH PLUMB MI INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received �-�j !t Phone Contact for Permittingrrrrrr Owner's Name 616VAIJAIXO R I A/0 Owner Phone Number " Owner's Address. 3 Owner Phone Number �- Owner Phone Number JOB ADDRESS S LOT'# SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN 0 = DEMOLISH; e INSTALL e REPAIR PROPOSED USE Q SFR• = COMM OTHER. TYPE OF CONSTRUCTION, = BLOCK Q FRAME 0• STEEL DESCRIPTIOMOF WORK O ( d swig—) BUILDINGSIZE SQ FOOTAGE HEIGHT F . =1 =BUILDING . $ 7 VALUATION OF TOTAL CONSTRUCTION b n-e;�—7"] =ELECTRICAL, ($�� AMP SERVICE 0 DUKE ENERGY W.R.E.C. =PLUMBiNG1$ � =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY OTHER f Y FINISHED'FLOOR ELEVATIONS ( . FLOOD ZONE AREA: . =YES NO E+p ,.......0. BUILDER C MPANY � �^ "��" " G � SIGNATURE t� 99 �) REGISTERED Y/.N FEE CURREN Address' �5 /!/ tO� /,0 License# I ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N" FEE CURREN "Y/N" Address 'License# PLUMBER COMPANY SIGNATURE 'REGISTERED Y/°N I FEE CURREN Y I N Address License# MECHANICAL COMPANY SIGNATURE;' REGISTERED Y/-.N FEE CURREN Y/.N Address, License#. OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# F — T I RESIDENTIAL Attach;(2)Plot Plans;,(2)sets of Building Plans;(1),set of.Energy Forms;WO-W Permit for new construction,'. Minimum=ten-(10)-working days after submittal.date.-Required'onsit%Construction Plans,.Stormwater Rlans irv/Silt Fence'.installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life.Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum-ten-_00)working.days aftersubmittal date. Required onsite,Construction-Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site•Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach.(2)sets.of Engineered.Plans. ""PROPERTY SURVEY required for all NEW construction.• Directions: Fill out application completely. Owner.&Contractor sign back of application,notarized If over$2500,a Notice of-.Commencement is required. (A/C upgrades over$7500) " Agenf(for the contractor)•or Power of Attorney(far:the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING ;(copy'of contract required) Reroofs if shingles Sewers Seniice;Upgrades!.A/,C, Fences."Plot/Survey/Footage) Driveways-Not over Counter if on pubk roadways::needs`ROW~ - NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which maybe more restrictive than County regulations. The undersigned assumes respdnsibility;for dompliance with,any applicable deed restrictions. UNLICENSED CONTRACTORS 'AND 'CONTRACTOR':"RESPONSIBILITIES: ' If the owner-has .hired a contractor or contractors.to undertake.work, they may be required to be licensed in accordance with-state and.local regulations, if the contractor is not licensed as required by law, both the owner and contractor may be cited for a'misdemeanor violation under state-law. If the owner or intended contractor are uncertain-as to.what.licensing.requirements may apply for the intended work, they are advised to contact the Pasco County Building lnspection Division—Licensing,Section at 727-847- 8009. Furthermore,.-if the owner has hired a contractor. or contractors,. he is advised. to .have the contractor(s) sign portions of the "contractor Block" of this application for which they will be.responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to=permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees'and Recourse.Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance.-number 89-07 and 90-07, as amended: The undersigned also understands,'.that such fees, as may be due, will be identified at the time of permitting. It is further.understood that TransOrtation Impact Fees and Resource Recovery.Fees must be paid prior.to receiving a "certificate of occupancy" or final power release. If,the project does not involve a certificate of occupancy or final power release,,.the fees must,be paid prior to permit issuance. Furthermore, if Pasco County.Water/Sewer Impact fees are due, they must be paidprior.to-permifissuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,.Florida.Statutes, as.amended): .If valuation of work is$2;500:00.or more, I certify that 1, the applicant, -have been provided- with a copy of the "Florida -Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If:the applicant,is.someone: other than the "owner", I certify-that I have obtaihed a copy of the-above described document and promise.in good'faith to deliver it to-the"owner"prior to commencement. CONTRACTOR'S/OWNER'S:AFFIDAVIT: .1 ce�ify that all the information:in this:application is accurate.and.that all,work. will be done in compliance with all applicable laws regulating construction, zoning and land development:,:Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and,1that all work will be performed to meef.standards of,.all laws regulating construction, County and City codes, zoning regulations; and'land development regulations in the jurisdiction. 1.also certify that I understand-that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify.what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, .Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Managlement District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health &• Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agenc,-Asbestos abatement. Federal Aviation Authority-Runways I understand:that the following restrictions apply,to the use of fill: Use.of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be subr itted at time of permitting which, is prepared°by,a„professional engineer licensed by the State of Florida. ' If the fill material is~to be used in Mood Zone "A" in connection with a permitted building using stem wall . construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be,used in any area, I certify that use of'such fill will not adversely affect-.adjacent properties. If use of fill is-found to adversely affect adjacent.properties, the-owner maybe cited,for violating the conditions of the building permit issued under.the attached permit application, for lots less than one.(1) acre which_are elevated by fill, amen ineered drainage plan is required. If I am4he AGENT FOR-THE OWNER, I promise in good faith to inform the'owner of-the permitting-coriditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical.work, plumbing, signs, wells, pools,- air conditioning, gas, or other installations not specifically included ,in the-application. A permit.issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter,:or set aside any provisions of the technical-Codes,'nor shall issuance of a permit prevent the Building-Official from thereafter, requiring a correction'of errors in plans, construction or violations of any codes: 'Every permit issued shall become invalid unless..the.work authorized-by,such.permit is commenced within six months.of permit issuance, or if work:authorized'by the permit is suspended or abandoned for a period of six(6) months after the" Aime'the work is commenced. An extension may be_requested,-in-writing, from the Building Official for a period not to exceed ninety (90) days and will;demonstrate justifiable cause for the'extension. If work ceases for ninety(90)consecutive days;,the.job is considered abandoned. WARNING TO-OWNER: YOUR FAILURE TO (RECORD. A NOTICE,.OP COMMENCEMENT. RESULT IN YOUR G 7dE--PAYINWl -FORIMPROVEMENTS TO�YOO- PROPERTY. IF YOU INTEND.TO.OBTAIN.FINANCING; CONSULT WITH.YOUR LENDER OR:AN,,ATTORNEY BEFbRE RECORDING YOUR;NOTICE OF`COMMENCEMEN FLORIDA JURAT(F.S.117.03) OWNER OR AGENT.-. CONTR�edC R Subscribed'and sworn to(or affirmed)before me this S bscribnAk affirmed)befor this by - , y2.5 Who is/are personally knowmto me or has/have produced ho is p rsonn to me or has/have produced; as identification. L cL1a f�2s51� 2 as identifcation. Notary Publi Notary Public Commission No. Comm JACQUELINE BODES Name of Notary typed,printed or stamped Name ' qp! ty� 0 Fi l 2 kos i'`.••`Bonded Thu Troy Fain Insurd=800-386r7019 CITY OF�f. ;',1I o � 4.11.S EEN DOW SEE iS s ��><�es a ALL VV'RK SHALL CC;mw Supplemental Instructions LY UVITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, Pan Doors_ Residential AND THE CITY OF ZEPHYRHILLS ORDINANCES Higher wind pressures and larger doors require additional reinforcement. ® CAUTION premature failure of door system may result from improper application. i See chart in lower left corner of drawing sheet one for the Opproved wind pressures and door sizes. These supplemental instructions do not contain basic door installation steps and related safety information.. !f & WARNIN. w i A aiwl a to follow basil:il-istaRation steps and related saffeby iintbrn-liatioa may result iirl k1jiiiT oi`deatl'1. ( door installers must follow a primary instruction manual for I basic door installation steps and related safety information. I F //� . The correct selection of door and framing materials in adherence.with local building code directives is the responsibility of the building owner/designer. �N� O @ rAN�t='°;� Usc of a reinforced garage door does not constitute automatic compliance with o IUo.5 � any building code. Local building code officials determine compliance criteria. A locking system must be installed if the door is not electrically operated. STATE OFip ` ee ae See drawing for stop molding requirements,when door is not more than 1"wider than opening. %s�.l�•.mt:OR��:''�i When using stop molding,secure molding with minimum 3d nails or 2-1/2" tong screws. 1S//°paS90NW�-��`\\ J John E.States,P.E. Digitally signed by John E.States P.E. 2560 King Arthur,Ste 124-54 Professional Engineers seal Lewisville,Texas 75056, provided oily fof verification of Date:2018.02.080 T:32:07-06-00- TXPE 56308,F-2203 windload construction details Supplemep-tar L*Istr actions Pan cocp—r.M 2017 CM.I.0v-jh.-_d ntc Florida RE.0 51737 Page I of 6 i I >10°Roof Slope/Residential Applications C.H.I. ASCE 7-05 ASCE 7-10 Pressure(PSF)by Door Width, Wind Zone ExpIBMPH ExpBMPH 8'xT 9'x7' 10'x7' 12'x7' 14' 7' 15'x7' 21ii x7' Zone 1 90 116 12.9/-14.7 12.8/-14.5 12.7/-14.3 12.5/-14.1 12.4/-13.9_ 12.3/-13.8 12.3/-13.7 'Zone 2 1 100 _ 15.7/-17.7 ', 15:5/-17A' 15:3/-17.1 _ 15:2/-17A W Zone 3 �10 4� 10.3/-21.n 10 1 _216 o nr�� lE. /-21^ 19.5/-2L 7 1&.4/-20.5 1S3/-20.4 �- . / 1 ,-21.4 7 Zone 4�? t12t7, 155'� 23 0%20.1 .' 22.8/ZS 8 22 6/25 5 _ ZZ:3/-E .O 22.OJ-24.6 2f9/-Z4:5. Zi.S/-24.3`� (lHO-ne one 5 -r1-330�- 168 27.0/30.6 _26.7J_30 2 26 5 29 9 26.21-293 25.9/-28.9-�25.7-28.7 25.6'-S one 6.~ 140.. 181'.; - s 31.3/-35.5 3L.0 35:1'+ ..;30:51-34:7 '.::":30.4/-34;0` _ 30.0%33.5 24 8/-333 _`-,2)X,,-33.1�; 7� 150 1194 35 9140 8 35.6140 2 35.3/39.8 34.809.1 39.1 34.4/-38-.5 34 3/-38.2 34.1/-38A_ 2^v /'Z.^.b 33 3.3' 3 3/w»:.._.._'.,W`....a_.'",�'%,.`.•`�'=_.a:.�.�t)';""" - �3�..2/.3.0. +39 017 3S, l+~�Zone 9 I 166M +f- 214 �i 43.9/-49.8 43.6/-49.3 43.3/-48.7 42.7/-47.8 42.2J-47.1 42.0/-46.8 41.8/-46.6 'the higher Exp B values apply to doors greater than SO'wide :910*Roof Slope/Commercial Applications C.H.I. ASCE 7-05 ASCE 7-10 Pressure(PSF)by Door Width Wind Zone ExpBMPH Exp BMPH 8,x8, VIS' 10'x8, 12'x8' 14'x8' 15'x8' z16'x8' 'Zone 1 90 116 11.*13.3 _ 11.6/-13.1 11.6/-13.0 i1.4/42.7_ _ 11.3/-12.6 11.2j-12.5 11_.2j-12.4 Zone 2: _ 1_00 M_ 129'-' 14.51-16.4 w 14.4/-15:2, w,14.3�16.0' ,>�14.1/-15.7 13.9/-15.5A 13.8/-15,4 H _Zone 3 _ W �110_ 142 17.5/-19.9 17.4�/-19.6 17.3/-19.4 17.01-19.0 16.8%18.8 `16.7/-18.6 16.7/-18.5_ Zone 4 120 155 -' 20 9/73 5 20.71T233 20.5/-23.? 20 3/2a 7 00 0J-_22.3 19.9/-22.2. AS/-22.1 Zone 5 130 168 _24 5/27 7 24 3/-27.4 24.11-27.1 23 8/26 6 23 5/-26.2 23.4/-26 0 233/-25.9 Zone b ._ �140 181 �LL 28 4/32 2-:u 28.2I-31:7 4 18 u/,31.4__;V - 27 b/i0 8 Zi j-30.4 Z7.iJ-30.2 ..w27.0%-30.�1T Zone 7 150 194 _ 32 6/-36.9 32.3136 4 321/-36 0 3L7/-35.4 313/-34.9 311/-34.7 31_%34.5_ L199;� I _34 8.8 � 34A/38 3_33.7['37 9 .,;:,33:3/-37 2� "32.9/36:7 �317/-365 32.6/-36.2. Zone 9 I�166 yl 214 I 39.8/45.0 39.4J-04.4 39.1/-44.0 38.6/-43.2 38.2/-42.5 38.0%42.3 37.8/42.0�� General Notes -Exp B values areto nearest miles-per-hour(MPH) ' -PreiFnreval.w,c are pmmdFper-square-fnnt(PSF) Mean Roof Height(MRHI/Exposures(Exnl -Positive pressure signifies pressure acting inward to the building MRH UP B Exp C Exp 0 Negative pressuresignlfies�ressure acting outward from the bu!Iding 15' _ _ 10WG _ 90% 82% -Enclosed structure dass!fi tlon with 2'of the door in the end zone -20 b ^�_�"8Boo '�T'80•�" -60'x40'building size jlarge i buildings may require higher negative PSF) 25' 100'!0 86% 78%� -30'Mean R Height(MRH),see chart for differing MRH and Exp va!uK -Greater door heights requlrle lower PSF values to meet same MPH - 35 97% 83% 76% ASCE7-05notes 45' _ 94% 80% 74% -Importance Factor of 1.00 A50' p92°rb 80 74% emu{ -U!!Il=n_eni nM/ha<_!c xInd speeds � � 55 ry� 915C 79%% 73% 60' 90'ia, :78ro 73% ASCE 7-10 notes - These percentages reduce Exp B wind speeds to approximate MPH for mean ouf -Risk Catergory 11 heights shown in MRH column. -Utilizes ultimate wind spee s ' 1 , I For Use With Drawing Number Z4-10-01306 Strut Placement I Door Height Section Number 6-6"to T-Ia" 7-6'to S'-0" 8'-3"to 9-9" 9'-0"to 19-6' 19-9"to 12-3" 12-6"to 14'-0" 14'-3"to 15'-9" 16'-0"to 17'-6" 17'-9"to 19'-3" 19-6"to 2g-o" 12 N/A N/A N/A N/A N/A N/A NIA N/A N/A I at Detail A i 1 r.T,'A N/A N/A N/A I N/A N/A N/A N/A I at Detail A C i 1 o N/A NIA N/A NIA NIA N/A N/A 1 at Detail A I at Detail B 1 at Detail B 9 N/A ( N/A NIA NIA NIA NIA I at Detail A I at Detail C I at Detail C I at Detail C I 8 N/A N/A NIA N/A N/A- 1 at Detail A 1 at Detail A- 1 at Detail A 1 at Detail A. 1 at Detail A 7 I. NIA N/A i3/A NIA 1 at Detaii A 0 a 0 0 0 I 6 N/A N/A N/A 1 at Detail A 1 at Detail B I at Detail B I at Detail B 1 at Detail B 1 at Detail B I at Detail B 5 N/A I I at Detail A I at Detail A 1 at Detail C 1 at Detail C I at Detail C I at Detail C i at Detail C I at Detail C I at Detail C 4 1 at Detai]A 1 at,Detail A I at Detail A 1 at Detail A 1,at Detail,A 1 at Detail A 1.at Detail A. 1 at.Detail A 1 at Detail.A 1 at Detail.A. - 3 a � a o a o_�-.�,. - a o o -: a a .. 2 1 at Det B 1 at Detail B I at Detail B 1 at Detail B I at Detail B 1 at Detail B l at Detail B I at Detail B I at Detail B I at Detail B 1 1 at Detail)C I at Detail C I at Detail C I at Detail C 1 at Detail C 1 at Detail C I at Detail C I at Detail C 1 at Detail C 1 at Detail C Push Nut Detail (use on all rollers) _ use 3/8"1.D.on bottom fixture roller stem use 7/16"1.D.on end hinge and top fixture roller stems Push nut:Slide roller into fixture and tap push nut onto roller stem using 1/2"socket and hammer. Leave 1/8"to 1/4"space between push nut and fixture. Track Bracket Spacing Track bracket spacing shown for doors up to four sections high.Additional C door sections ay be added for maximum door height depicted online nn i drawi Tram brackets must be added(per track}for each section and spaced at a dish,nce not greaicr titan the co—ru-sponding section height(See I ' line drawing f i required quantities). Strut Placement Concerning Windows Where a strut crosses a window,it is acceptable to move the strut from a position of"Strut above hinge"down to"Strut on top half of the hinge". Nontiad B SPa^M'£ 1 Strut Stntt C 38„ B 28" ` A I n in" I. rzgFfinge '"-- End Hinge ff-Y tolerance � Strut above I Inge Strut of top half of hinge Page 3 of 6 For Use With Drawing Number Z4-10-01306 Strut Placement Detail Strut End Hinge End Hinge 4 /- Strut I' End Hine •I y or End Hinge Bottom Fixture Strut.above hinge Strut below hinge Strut in center of section Det it A Detail B Dctail C Optional.Windows Intermediate Hinge _I !F/7. . I•I1:�;�Al•!lf.T/ F7,71� /-Strut B Strut C Strut 3 Struts Page 4 of 6 4 3 2 1 Ghtrittg Options;(,max daylight opening 39-3/8"x 12-IX) ^1/B"DSB "l/C Tempmd Glass or Potycadomae "7/16"lusulatd Glass w/opt for Tcopend ll (Ill I 16-0"width shown (see totes fa ether widths) Optional Windows (see Glazing Options) 6-6"m 7-0' 4 3 2 C Top Fiume 1D B'-3'to 8'-9' 5 4 3 C 4D Flag 9'-0"to 10'-6" 6 5 4 Z Bracket 19-9"to 12'-3" 7 6 5 a 7• Emi Stile A I IT-6"tot4'A" B � G G I QET I li- 2 I I 16-0"to IT-6" 10 B 8 �I I PAW HhW 4A 'track . 2 Bracket t9'fi"w 20'-0" 12 9 10 Bottom FiA[me Ttackbmckaquanthies shown are far use with grade 2 orbeaer Southem 2B ?A Yellow Fine.Refer to Jamb Attadmtatt Detail supplement insmtetim,s for B 2 2 mage of ahemate,pmb matrwl B L�aelrnedise Strut D-iailsfr doerhAghtsupto27.0" Hine are comamed in the Supplememal lasuuctions,which are required in addition to&is dtawiug for iustadation. 1 s z' D, ndo anerw:.y Cetythis ®"e`E�a�. ��� S�pponns"�,m,�,eiememaabau Tlrisdoo,has 1—evahWd in an —..with ASfM F.330-9M..-A � • / he desiguni by ategishaed pndtastwwl ANSWMSMA 108-'=2,108-200S&108-2012 ; j ntganzr fur rirel Iuada shuwuuu situ 4 a ��.51737 ; dmnvng.if dooris not clecuically Applictble wild spells ace dependent on boildiog envelope .�."' a . ofetatd,a lock tuant be installed. and most be deoxmined in compliance with relevaut ASCB 7, I * a =orIRC staahm;s tit n.xcregt and atst 1,.:A asgido mctU Maximo®doorbeighe 21Y-00` �'�; STATE OF �•'Q` Glaringatddoor hay.notbmt for wiudbome debris. 0��� . r A'GR .- . , Zl;t nts (J//�!� ¢ 0� j Solo E.Scales.P.E. ® OS-25-201.7 —J 2560 King Arthur,Ste 124-54 Models:2X4X,2X5X,4X4X, ProfessionaLEngUteer's seal provided Lewisville,TX 75056 4XSX-52XX,59XX only for vedfiration of windioad TXTE 563D8,F-2203 unutructiom details Florida RE F 51737 C KL 1kAwinn:7A-10-01306 pane 1 of 2 4 3 2 1- City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: [ �2-3-1 Site: �YT / 6 Permit Type: r- (AC A( 7 Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ i This comment sheet sh 1' be kept with the permit and/or plans. OCT 3 1201 Kalvin Sw r Plans Examiner Date Contractor and/or Homeowner (Required when comments are present)