HomeMy WebLinkAbout19-21935 CITY OF ZEPHYRHILLS
5335-STH STREET
(813)780-0020 21935
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:21935 Issued: 11/15/2019 Address: 5885 13TH ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 214,485.60 Total Fees: 18,081.47 Subdivision: CITY OF ZEPHYRHILLS
Amount Paid: 15,357.47 Date Paid: 11/15/2019 Parcel Number: 11-26-21-0010-03800-0051
CONTRACTOR INFORMATION OWNER INFORMATION
Name: BOBBY E. HILTON CONST INC Name: HILTON, BOBBY E JR
Addr: 5415 16TH ST Address: 39942 OTIS ALLEN RD
ZEPHYRHILLS, FL. 33540 ZEPHYRHILLS, FL 33540-7715
Phone: (813)997-0515 Lic: Phone: 813-997-0515
Work Desc: CONSTRUCT SINGLE FAMILY 1,904 SQ FT
APPLICATION FEES
PLUMBING FEE 167.2 RESIDEW 2,0-9000 -E—LE-CTRICAL FEE 250.89-
WATER CONNECTION RESIDENT 1,010.00 MECHANICAL FEE 117.08 SCHOOL IMPACT FEE-sfr/1% 77.28
SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68
BUILDING FEE 1,212.29 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF ✓ 769.56 WATER METER RES 3/4" 473.78
fi
Inspections Reauired
FOOTER 2ND ROUGH PC M13 mibu INSULAT N CEIEING
FOOTER BOND (/D� DUCTS INSULATED SEWER misc.
ROUGH ELECTRIC LINTEL misc misc.
1ST ROUGH PLUMB- I 1 PRE-METER INSULATION WALL misc.
DUCTS INSTALLED— WATER misc DRIVEWAY
PRE-SLAB SHEATHING misc. misc.
CONSTRUCTION POLE_ FRAME misc. I misc
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for,each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTbftSSIGNATURE PERMIT OFFI09h
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Jacqueline Boges
From: City of Zephyrhills Support <support@zephyrhillsfl.zendesk.com>
Sent: Friday, November 15, 2019 3:43 PM
To: Jacqueline Boges
Subject: [Request received] 5885 13th st by#21935
EXTERNAL EMAIL
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/298991
.......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
Nov 15, 1 :42 PM MST
services 5885 1 3th st by 21935
This email is a service from City of Zephyrhills Support .
1
11-26-21-0010-03800-0051 1 Pasco County Property Appraiser Page 1 of 1
Parcel ID 11-26-21-0010-03800-0051 (Card: 1 of 1)
Classification 00000-Vacant
Mailing Address Property Value
HILTON BOBBY E JR Ag Land $0
39942 OTIS ALLEN RD Land $14,686
ZEPHYRHILLS, FL 33540-7715 Building $0
Extra Features $0
Physical Address
5885 13TH STREET, Just Value $14,686
ZEPHYRHILLS, FL 33542
Assessed (Non-School Amendment 1) $14,686
Legal Description (First zoo
characters)
See Plat for this Non-School Taxable Value $14,686
School District Taxable Value $14,686
Subdivision
CITY OF ZEPHYRHILLS PB 1 PG 54
LOT 5 & POR OF LOT 4 & N1/2 OF
LOT 6 DESC AS COM AT SE COR OF
BLOCK 38 TH N23DEG21'39"W
134.95 FT FOR POB TH S66DEG37'
06"W 139.84 FT TH N23DEG23'
41"W 52.50 FT TH N66DE[...]
Jurisdiction
CITY OF ZEPHYRHILLS
Land Detail (Card: 1 of 1)
Line Use Code Description __ ',ZoninglUnits _Type Price C n tion Value
1 0100V J LP2-1 SFR 10OR2 17,343.00 1 SF $2.00 1.00 $14,686
Additional Land Information
Acres _Tax Area _ FEMA Code Res Code Corn Code Condo Code
0.17 30ZC -- ZHLH ZHLH ZHLH
Building Information (Card: 1 of 1)
Unimproved Parcel
Extra Features (Card: 1 of 1)
Line Code IDescription Year Units Value
No Extra Features
Sales History
Previous Owner: N/A
Month/Year Book/Page Type DOR Code Condition Amount _
04/2018 9708 / 2837 Warranty Deed 1 11 1 Vacant I $0
http://search.pascopa.com/parcel.aspx?parcel=2126110010038000051 10/21/2019
D
Q
1
a
Single Family Dwelling
Plan Review Comments
1. F.F.E; shall be a inini'mum of 8" above the road elevation and an engme'ered site plan.
2! Lots shall be graded to comply with R401;3 of the F.B.C.
3. Compaction test required if 24"or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8; All A.D.A.-requirements, shall be met;
9. No electric, plumbing,mechanical,or.framing shall be covered without an inspection and
approval first:
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303..4 of the F.B.0
12. Water heaters shall "comply with section P607.3 of the F:B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. MI30U
14. Returii air in all bedrooms. F.B.-C. M1620.4
15. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C;
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum.board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an A.FCI type brea4.'r-
20. Carbon nmonoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage.' They shall be installed in accordance with the F.B.C:
21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all
underground plumbing and.electric.
22. All 2016 N:E.C. Codes will be enforced.
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N..E:C
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25.. R403.*5.3Hot.water pipe insulation.
insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the
following:
Piping.3I, inch (1.9.1 mm)and larger in:nominal diameter.
Piping serving,more than:one dwelling unit.
Piping located outside the conditioned space.
Piping from the:water heater to a distribution manifold..
Piping located under a floor slab.
Buried in piping.
Supply and return piping in recirculation systems other than demand recirculation systems.
25. Blower door test shall be provided before C.O.
26.A cony of the enerey-cacls shall be with permit at all times.
27. Coot/of final-insulation-report shall be provided with permit before fnaL
28. No fence, pool or screen enclosure :is issued with this permit
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 6t'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016)
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0
Building Department
Date Received Phone Contact for Permitting --
Owner's Name H 1 1lo-ti ' Owner Phone Number
Owner's Address M;L O)6, 14 y 1"Q Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple'Titleholder Addresses f JOB ADDRESS S�O J J �� Z-r )-1 m),\)�s< 5 S H-D. LOT#
SUBDIVISION PARCEL ID# —a 6J 01 CIo\o
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR e ADD/ALT = SIGN = DEMOLISH
INSTALL REPAIR
PROPOSED USE E� SFR = COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK FRAME = STEEL =
DESCRIPTION OF WORK
BUILDING SIZE G� �X 0/5 h SQ FOOTAGE !d7 HEIGHT
=BUILDING ALUATION OF TOTAL CONSTRUCTION
=ELECTRIC $ MP SERVICE = PROGRESS ENERGY Q W.R.E.C.
=PLUMBING $ U OLK
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATIOVjV ^ ) (�
=GAS = ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO G(
BUILDER / COMPANY �� a� GeR�c�'�a� �/�1C..✓
SIGNATURE `' REGISTERED Y/ N FEE CURREN Y/N
Address 3o,9,y a c f I S q d ' License#
ELECTRICIAN COMPANY DIM 4YajPa ��c d& 1;r'51 (19JJ Lflee*jC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address y/ �NYA/)U 33 5-VJ License^# ,Ee 00!)2570
PLUMBER ? � "� COMPANY 'e,nn S
SIGNATURE REGISTERED N FEE CURREN N
Address JI()k 110 !& ' 7 1 P It �S I FC 3 3SCra' License# �i�L' L a!!aa 9 a
MECHANICAL � / COMPANY
SIGNATURE / REGISTERED Y/ N FEE CURREN Y/N
Address License# e-yco
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities,&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"*"PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
" Agent(for the confractor)or Power of'Atfornev(for the:owrier);would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING.-. ... ,(ggpy.pf contract requited)
Reroofs if shingles Sewers: Service.Upgrades.A/C :Fences(Plot/Survey/Footage)
Driveways-Not over Counter-if on.public roadways::needs•ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may,be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application.for which they will be responsible. If you, as the owner sign-as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does'not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner' prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and.land development.. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work-or: installation has
commenced prior to issuance of.a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone"V' unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical:'work,
plumbing, signs,.,wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violafe,;cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors:in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized la i such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned;
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT _
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(o rm efore is
by .�
Who is/are personally known to me or has/have produced Who is/are fo the or has/hgvg Oroduced
as identification. as identification.
Notary Public Gx4u4tl A Notary Public
Commission No. Commissi o.
a c , dANQMIKE 90GES
Name of Notary typed,printed or stamped Name of Notary d,pt I
�:�@ tuber 2Q22
;t° BordeoP.wT.r,�F:i.U=::ac:o800.38ST019
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: R0818410 r Builder Name: Bobby Hilton C nstruction,Inc. •��
Street: ��� 3 Permit Office: WinterPBtk�4 7�I
City,State,Zip: Zephyrhills,FL,33540 Permit Number. 24 g3
Owner: Bobby Hilton Construction,Inc. Jurisdiction: 582466 110M
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1414.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 1117.30 ft2
b.Frame-Wood,Adjacent R=13.0 296.67 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1381.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1381.00 ft2
6. Conditioned floor area above grade(ft2) 1382 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(104.1 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 225
a. U-Factor: Dbl,U=0.33 104.10 ft2
SHGC: SHGC=0.28
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 24.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Strip Heat 24.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.309 ft.
Area Weighted Average SHGC: 0.280 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1382.0 sqft.) Insulation Area EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1382.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits CF,Pstat
Glass/Floor Area: 0.075 Total Proposed Modified Loads: 41.96 PASS
Total Baseline Loads: 43.85
1 hereby certify that the plans and specifications covered by Review of the plans and ��g1lE ST,q��
this calculation are in compliance with
the Florida Energy specifications covered by this O,,t,
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: 08-14-18 this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code. COD y�rrn'T��
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE: OCT Mg
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory6-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
8/14/2018 11:49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Tit1w. R0818410 Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1382 Lot#
Owner Name: Bobby Hilton Construction,In Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Bobby Hilton Construction,In Rotate Angle: 0 Street:
Permit Office: Winter Park Cross Ventilation: No County: Pasco
Jurisdiction: 582400 Whole House Fan: No City,State,Zip- Zephyrhills,
Family Type: Single-family FL, 33540
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL-TAMPA-INTERNATI 39 91 70 75 645.6 54 Medium
BLOCKS
Number Name Area Volume
Entire House 1382 11056
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
I Bed2 165 1320 No 1 1 1 Yes Yes Yes
2 Wic 37 296 No 0 1 Yes Yes Yes
3 MBed 200 1600 No 2 1 1 Yes Yes Yes
4 Closet 31 248 No 0 1 Yes Yes Yes
5 Bed3 148 1184 No 1 1 1 Yes Yes Yes
6 Kitchen 211 1688 Yes 0 1 Yes Yes Yes
7 Living 288 2304 No 0 1 Yes Yes Yes
8 Bath 67 456 No 0 1 Yes Yes Yes
9 Pantry 22 176 No 0 1 Yes Yes Yes
10 mWic 65 520 No 0 1 Yes Yes Yes
11 MBath 87 696 No 0 1 Yes Yes Yes
12 Hall 71 568 No 0 1 Yes Yes Yes
FLOORS
V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
- 1 Slab-On-Grade Edge Insulatio Bed2 26.7 ft 0 165 ft2 0 0 1
2 Slab-On-Grade Edge Insulatio Wic 9.3 ft 0 37 ftz 0 0 1
- 3 Slab-On-Grade Edge Insulatio MBed 28.3 ft 0 200 ft2 0 0 1
- 4SIab-On-Grade Edge Insulatio Closet 2.3 ft 0 31 ft2 0 0 1
- 5 Slab-On-Grade Edge Insulatio Bed3 11.7 ft 0 148 ft2 0 0 1
811412018 11.49 AM EnergyGauge@)USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
6 Slab-On-Grade Edge Insulatio Kitchen 12.7 ft 0 211 ft2 0 0 1
7 Slab-On-Grade Edge Insulatio Living 34 ft 0 288 ft2 — 0 0 1
8 Slab-On-Grade Edge Insulatio Bath 1 ft 0 57 ft2 — 0 0 1
9 Slab-On-Grade Edge Insulatio Pantry 1 ft 0 22 ft2 — 0 0 1
10SIab-On-Grade Edge Insulatio MWic 6.7 ft 0 65 ft2 — 0 0 1
11SIab-On-Grade Edge Insulatio MBath 9 ft 0 87 ft2 — 0 0 1
12SIab-On-Grade Edge Insulatio Hall 1 ft 0 71 ft2 — 0 0 1
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 1496 ft2 288 ft2 Light 0.65 No 0.9 No 0 22.6
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1381 ft2 y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Bed2 38 Blown 165 ft2 0.1 Wood
2 Under Attic(Vented) Wic 38 Blown 37 ft2 0.1 Wood
3 Under Attic(Vented) MBed 38 Blown 200 ft2 0.1 Wood
4 Under Attic(Vented) Closet 38 Blown 30 ft2 0.1 Wood
5 Under Attic(Vented) Bed3 38 Blown 148 ft2 0.1 Wood
6 Under Attic(Vented) Kitchen 38 Blown 211 ft2 0.1 Wood
7 Under Attic(Vented) Living 38 Blown 288 112 0.1 Wood
8 Under Attic(Vented) Bath 38 Blown 57 ft2 0.1 Wood
9 Under Attic(Vented) Pantry 38 Blown 22 ft2 0.1 Wood
10 Under Attic(Vented) MWic 38 Blown 65 ft2 0.1 Wood
11 Under Attic(Vented) MBath 38 Blown 87 ft2 0.1 Wood
12 Under Attic(Vented) Hall 38 Blown 71 ft2 0.1 Wood
WALLS
Adjacent Width Height Sheathing Framing Solar Below
Cavity
e Space R-iai„e Ft In Ft In Area R-Value—Fraction—Absor Grade
_ 1 N Exterior Frame-Wood Bed2 13 13 0 8 0 104.0 ft2 0 0.25 0.1 0
2 W Exterior Frame-Wood Bed2 13 12 8 8 0 101.3 ft2 0 0.25 0.1 0
_3 S Exterior Frame-Wood Wic 13 5 4 8 0 42.7 ft2 0 0.25 0.1 0
_4 W Exterior Frame-Wood Wic 13 4 0 8 0 32.0 ft2 0 0.25 0.1 0
8/14/201811:49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
SpaceR-Value-
rea_5 S Exterior Frame-Wood MBed 13 13 8 8 0 109.3 ft2 0 0.25 0.1 0
_6 W Exterior Frame-Wood MBed 13 14 8 8 0 117.3 ft2 0 0.25 0.1 0
_7 N Exterior Frame-Wood Closet 13 2 4 8 0 18.7 ft2 0 0.25 0.1 0
_8 N Exterior Frame-Wood Bed3 13 11 8 8 0 93.3 112 0 0.25 0.1 0
_9 N Exterior Frame-Wood Kitchen 13 12 8 8 0 101.3 ft2 0 0.25 0.1 0
10 S Garage Frame-Wood Kitchen 13 5 0 8 0 40.0 ft2 0 0.25 0.1 0
_11 N Exterior Frame-Wood Living 13 17 4 8 0 138.7 ft2- 0 0.25 0.1 0
12 E Exterior Frame-Wood Living 13 16 8 8 0 133.3 ft2 0 0.25 0.1 0
13 S Garage Frame-Wood Living 13 17 4 8 0 138.7 f12 . 0 0.25 0.1 0
14 E Garage Frame-Wood Pantry 13 5 0 .8 0 40.0 ft2 0 0.25 0.1 0
_15 S Exterior Frame-Wood MWic 13 6 8 8 0 53.3 ft2 0 0.25 0.1 0
_16 E Garage Frame-Wood MWic 13 9 9 8 0 78.0 ft2 0 0.25 0.1 0
17 S- Exterior Frame-Wood MBath 13 9 0 8 0 72.0 ft2 0 0.25 0.1 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E Insulated Living None .35 3 6 8 20 ft2
2 S Insulated Kitchen None .46 2 7 6 7 17 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 W 2 TIM Low-E Double Yes 0.33 0.28 N 15.0 ft2 1 ft 0 in 6 ft 0 in Drapes/blinds Exterior 5
2 W 6 TIM Low-E Double Yes 0.33 0.28 N 20.1 ft2 5 ft 0 in 1 ft 2 in None None
3 W 6 TIM Low-E Double Yes 0.33 0.28 N 15.0 ft2 5 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
4 N 8 TIM Low-E Double Yes 0.33 0.28 N 15.0 ft2 1 ft 0 in 1 It 0 in Drapes/blinds Exterior 5
5 N 9 TIM Low-E Double Yes 0.33 0.28 N 9.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
6 E 12 TIM Low-E Double Yes 0.33 0.28 N 30.0 ft2 4 ft 4 in 0 ft 8 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 420 ft2 420 ft2 64 It 8 ft 1
INFILTRATION
# Scope Method SI.A CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1289.9 70.81 133.17 .2649 7
8/14/201811.49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6
FORM;R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COPI 24 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:16 24 kBtu/hr 800 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 225 ft2 Attic 150 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling (( ]]Jan r 1 Feb [[ ]]Mar Apr [ 1 Ma n [XJ Jul Au Se [ ]Oct [ Nov Dec
Heatin [X]Jan [X]Feb [X]Mar f APr [ ]May nju
Jun [ ]Jul AuSep [ ]Oct (X]Nov Dec
Venting [[ ])Jan IIII ])))Feb [[�X]]Mar [X)Apr [ )))May Jun [ l Jul Aug Sep [X)Oct [X]Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
8/14/2018 11:49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6
FORM-R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bed2
Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC
Default(8 Ibs/sq.ft. ft2 ft 0.3 MBed
Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bed3
Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen
Default(8 Ibs/sq.ft. ft2 ft 0.3 Living
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath-
Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry
Default(8 Ibs/sq.ft. ft2 ft 0.3 MWic
Default(8 Ibs/sq.ft. ft2 ft 0.3 MBath
Default(8 Ibs/s .ft. ft2 ft 0.3 Hail
Name: Tina M Neace Signature:
Rating Compant: Tina M Neace Date: 08-14-18
8/141201811:49 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*= 96
The lower the Energy Performance Index,the more efficient the home.
1.New home or,addition 1. New(From Plans) 12.Ducts,location&insulation level
a)Supply ducts R 6.0
2.Single-family or multiple-family 2. Single-family b)Return ducts R- 6.0
c)AHU location Attic/Attic
3.No.of units(if multiple-family) 3. 1
4.Number of bedrooms 4. 3 13.Cooling system: Capac1tyg4.0
a)Split system SEER 16.0
5.Is this a worst case?(yes/no) 5. Na b)Single package SEER
c)Ground/water source SEER/COP
6.Conditioned floor area(sq.ft.) 6. 1382 d)Room unit[PTAC EEk_
a)Other
7.Windows,type and area
a)U-factor(weighted average) 7a. 0.330
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.280 14.Heating system: Capacity 24.0
c)Area 7c. 104.1 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8.Skylights c)Electric resistance COP 1.0
a)U-factor:(weighted average) 8a. NA d)Gas furnace,natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA a)Gas furnace,LPG AFUE
f)Other
9.Floor type,insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood,raised(R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a)Electric resistance EF 0.97
b)Gas fired,natural gas EF
10.Wall type and insulation: c)Gas fired,LPG EF
A.Exterior: d)Solar system with tank EF
1.Wood frame(insulation R-value) 10A1. 13.0 a)Dedicated heat pump with tank EF
2.Masonry(insulation R-value) 10A2. 9 Heat recovery unit HeatRecP/6
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 13.0
2.Masonry(Insulation R-value) 10132.
16.HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans Yes
a)Under attic 11a. 38.0 b)Cross ventilation No
b)Single assembly 11b. c)Whole house fan No
c)Knee walls/skylight walls 11c. d)Muffizone cooling credit
d)Radiant barrier installed 11d. Yes a)Multizone heating credit
Q Programmable thermostat yes
*Label required by Section R303.1.3 of the Florida Building Code,Energy Conservation,if not DEFAULT.
I certify that this home has complied with the Florida Building Code,Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: City/Ft.Zip: Zephvrhills,FL 33540
8114/2018 11:50:19 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
INSTR#ZO19164443 OR BK 9979 PG !442 Page 1 of 1
09l2512019 03:05 PM Rcpt:2093941 Rec:10.00 DS:0.00 IT:0.00
Nikki Aivar Sowlec Feo Pae a County CIf,rk R ornptroller
i
PamNt No. Parcel ID No
NOTICE OF COMMENCEMENT
S,." _F7e R dA Comfy of
r
tviF'J1i!!3 I,C• Z�SB'hy4^'.425'ttd::`": ',.,, %1fl�7til mad6dOi Ta7�8t.P,eop�tY.mum in eecwdmce Mft amp"713.Saida Ststutse.
Bra tepd6r4agTtdam}agon'ia prgNded br Ilus Nditce oT
i. Desc+iP6or+osProa�Y:.ean�l.tdamtncs6an No. 1 — a�—a _'0-1 o ��3, 005),
Street Address: y��85 �.�-Tf' 4'e Y e t}�J �4• .`�r`t�
2. General Desalption or improvement 2 `i.a tyr, S i:Lg k
3. ownailt�to�matlarprLesaeeir�trnatioaffi2ha.kesaeasorlL.ar �
f obb }tY�
?, Li1 N &is A,?, 2d- Zrp1,y2 R-
A UVM . City State
interest In Propery: O.o y Mr?
Nome or Fee Simple Titleholder.
5(Kerdirroa3 OMeux,t�td olurve)
Address
4. conuedw. N��Ott y 1 � Cc,, R � give Ocy State.
{ u i uu
•��q�4a o"t'is Alkti �'a, Zrp)Tyit{ji12S �). �b'Q ., T".Z
Address city state a
conuracttoes Tetephona No.:
S. Suretyc. s r.
NameCOP
State �� •'?x�� �,. �� �pl��
AmolIIlt'orBo1N1 E' Tekphatallo.: `' •Q 1 n�i r lbw
.sue xx
6. Lander:
NameCO
Addra" city State -• � h a
_ .. .... LeNei's Telephone No.: ®_
T: P.a w=•vw1Kn,hq.State attflodda'd bydhe amw i.tpoh u+lrwm.hogaes ar'01hEt:dootRlfliFli`ytt8y rat served ms:Provitled by
�cniis:2:{t:)(a�s,:'{::Tcr'.dastaaatas: .
Name
LLI
Address city seta v) W W
Telephone Number ofOestgnted Person: (D ,E u- (J
$ OYaddreo_r�mtitmseiG¢tarowne�dmai9smtrs of- 4 U O cv
-��-r 0
torecebre a copy of 9re tlenot s Ntrtite as prouidad to Ser�6rrTt3 t3(1 FlaidaStaNtes a. Ur ' x <
TeleptwwNtpWal'PersenarE►RityDest9�dby . cr W z 03 d a
9. Expiration data of Natloo of Commencement(Ihe expiration date may net be betoro the lion of constam'ffan and Tint payment to the C 1 -17
.I._. p
contractor,but tNg be one year tram the date of recording unless a different date Is apecified): t.j LL jr U
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER T}IE EXPIRATION OF THE NOTICE OF COMMENCEMENT _ Ott
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713•PART 1 SECTION 713.13 FLORIDA STATUTES.AND CAN - h 7= tt 06
RESULT-IN YOUR PAYING TWICE FOf? IMPROVEMENTS TO YOUR PROPERTY. A N6fU OF COMMIENCEMENT MUST BE C) I- 4- �O �
;RE6QRpED ANtt'POa^�D:00.TNE 4.og..m.BEFORE THE FIRST INSPECTION...IF YOU INTEND TO OBTAIN FINANCING,CONSULT t Y ^�L 0
i+tlRtyYCiUR:tEND6ROR'l1NATTORNEYBEFORE,COMMENcINr.woRK+ORREMMINGYOLM+NOT.;rEOFOOWENCEMENT.
ltrMeritMrdhyoFpai tnr.aeacbnat52atl:travareait.detbregans+uticeaiaoinmasue+Hameretrratne tsstakatlowseimaaaiecDa."nest h t— _j Q
ormykmow9edgeandbaijeL tU Cl u C)
tx I.- cr CL z o
STATE OF FLORIDA 0 CK X tL k
COUNTY OF PASCO iginabne of or Lesaea or Lessee's Audwdzed Lr- (..) 0
010cer Auanager 4 0 Q p
o graattaySTltial0lfwe. ,_ Lu t Z
ThaforagotmgtnsWmerdvtasadmowlad9adb^efaryra�m/'')eQds�day Z —
1r1'1(% F (typo of aldh ;e g,officer;trustee,attrAmay in.iad)":Tor: }— F- 0S m
I!`��6n C- 9,„ 601"1 _ ("Mane of am chair of whom inebu was exeated).
�i---'iced rdettificau --- Notary Signature
Typo of tdgnttalcatton Produced ! Y1*Al Name(Prfit)
STEPNANiE RAPPAPORT
Flo0
Florid Notary Public,State of a
Commissional GG 2500S3
My Comm.expires Aug.19.2022
wpdetarncsatogoerbrmtenaemeny�ot7b3048
00
45
ROo
i3
3�'
Project Summary Job: R0818410
Wrl htsoft� •y Date: 08/1012018
9 Entire House By- MKC
Bobby Hilton Construction, Inc. Plan: 611600
39942 Offs Allen Rd,Zept"Ils,FL33540 Ptnre:(813)997-0515
Project • •
For. Bobby Hilton Construction,Inc.
Zephyrhills,FL 33540
Notes: Load calculation was obtained from a digital copy of the CAD drawing.
Design Information
Weather. Tampa Intl AP,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 12742 Btuh Structure 13002 Btuh
Ducts 3022 Btuh Duds 4413 Btuh
Central vent(0 ctm) 0 Btuh Central vent(0 din) 0 Btuh
none
Humidlfic,ition 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipmentload 15763 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17415 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2352 Btuh
Duds 1307 Btuh
Central vent(0 ctm) 0 Btuh
Heatingg Coolingg (none)
Area(ft) 1382 1382 Equipment latent load 3659 Btuh
Volume(fP) 11056 11056
Airchanges/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 21074 Btuh
Equiv.AVF(cfm) 83 42 Req.total capacity at 0.75 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Franklin or Eqv. Make Franklin or Eqv.
Trade SplitHP Trade Split HP
Model GSZ160241 Cond GSZ160241
AHRI ref 201667298 Coil ASPT291314
AHRI ref 201667298
Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER
Heating input Sensible cooling 18000 Btuh
Heating output 24000 Btuh @47-F Latent000ling 6000 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual airflow 800 ctm Actual airflow 800 cfrn
Airflowfactor 0.051 cm/Btuh Airflowfactor 0.046 cfrnBtuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.83
Capacity balance point=33 OF
Backup:Aux Heat
Input=5 kW, Output=17061 Btuh,100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoft` RigF w— tSu 2018-Arg-1411:45�8fe�Universal 201818.0.19 RSU20773 Page 1
ACACK..818410-Bobby FGltonCorshrfion\M818410np Calc=MJ8 FrordDoorfaces:E
Manual S Compliance Report Jab: R0818410
wrightsoft Date: 0811012018
Entire House By. MKC
Bobby Hilton Construction,Inc Plan: 611600
399420fisAJ[en Rd,ZaptWNIKFL3354OPhore:(813)997-0515
Project Information
For Bobby Hilton Construction,Inc.
Zephyrhills,FL 33540
Cooling Equipment
Design Conditions
Outdoor design DB: 91AOF Sensible gain: 17415 Btuh Entering coil DB: 77.3°F
Outdoor design W& 7721F Latent gain: 3659 Btuh Entering coil WB: 63.8°F
Indoor design DB. 75.0°F Total gain: 21074 Btuh
Indoor RH: 50% Estimated airflow: 800 clrn
Manufacturer's Performance Data at Actual Design Conditions
Equipmentlype: SplitASHP
Manufacturer. Franklin or Eqv. Model: GSZ160241+ASPT29B14
Actual airflow. 800 cfrn
Sensible capacity. 18000 Btuh 103%of load
Latent capacity- 6000 Btuh 164%of load
Total capacity: 24000 Btuh 114%of load SHR, 75%
Heating Equipment
Design Conditions
Outdoor design DB: 42.9°F Heat loss: 15763 Btuh Entering coil DR 69.1°F
Indoor design DB- 70.0°F
Manufacturer's Perfonnance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer. Franklin or Eqv. Model: GSZ160241+ASFrT29BI4
Actual airflow. 800 cfirn
Output capacity." 24000 Btuh 152%of load Capacity balance: 33 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Bec strip
Manufacturer. Model:
Actual airflow. 800 cIrn
Output capacity. 5.0 kW 108%of load Temp.rise: 31 OF
Meets all requirements ofACCA Manual S.
wrightsoft- 201&kg-1411.4558
PJgtt-SUteDUrivefsal20l8i8D.19RSU2DT73
Page 1
818410-BobbyHltDnODrsVucdonMB184I0np Calc=W8 FrortDoorfacm E
Hilton Construction-588513th St. 1904 sgft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 1,904 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 214,485.60
FEE SHEET $ 1,115.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,212.30
ELECTRICAL: $ 250.88
PLUMBING: $ 167.25
MECHANICAL: $ 117.08
SUB-TOTAL $ 1,747.60
TOTAL $ 1,747.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,874.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,728.00
100.0% $ 7,728.00
1.0% $ 77.28
TOTAL: $ 7,805.28
T I F'S: $ 3,632.00
99%1
$ 3,595.68
1% $ 36.32 P
TOTAL: $ 18,081.47