Loading...
HomeMy WebLinkAbout19-21988 CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 21988 ELECTRICAL PERMIT (PERMIT INFORMATION LOCATION INFORMATION Permit#:21988 Issued: 11/15/2019 Address: 38843 SOUTH AVE Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 46,000.00 Total Fees: 405.00 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 405.00 .Date Paid: 11/15/2019 Parcel Number: 11-26-21-0010-21400-0140 CONTRACTOR INFORMATION OWNER INFORMATION Name: ESD HOME SOLUTIONS LLC Name: STRAUGH, EDWARD& DEBORAH Addr: 7201 BRYAN DAIRY RD Address: 38843 SOUTH AVE LARGO, FL 3377 ZEPHYRHILLS, FL. 33542 Phone: (813)390-9556 Lic: Phone: 813-713-1068 Work Desc: INSTALLATION SOLAR PV SYSTEM ROOF MOUNTED APPLICATION FEES ELECTRICAL FEE 405.00 I INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL R t �v REINSPECTION FEES:(c)With respect to Reinspection fees will com y with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount lof the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. i All work shall be performed in accordance with City Codes and Ordinances. - I I i C PER OFF( PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Z6phyrhille Permit Application Fax-813-780-0021 Building Department i Date Received phone Contact for Permitting 727 940 — 3256 Owner's Name STRAUGHN EDWARD S&DEBORAH L Owner hone Number 8137131068 Owner's Address 38843 SOUTH AVENUE,ZEPHYRHILLS,FL 33542 Owner 1 hone Number Fee Simple Titleholder Name I Owner I Phone Number Fee Simple Titleholder Address JOB ADDRESS 38843 SOUTH AVENUE,ZEPHYRHILLS,FL 33542 LOT# 14 15 8 16 " I SUBDIVISION CITY OF ZEPHYRHILLS PARCEL ID# 11-26-21-0010-21400-0140 (O TAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR B ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE © SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 15.34 kW BUILDING SIZE I SO FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 46000 AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION A =GAS = ROOFING = SPECIALTY = OTHER v FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER Qi Ci COMPANY E§D HOME SOLUTIONS LLC SIGNATURE ✓ REGISTERED 11N FEE CURREN Y/N Address 7201 BRYAN DAIRY RD LARGO FL 33777 License# EC13008844 ELECTRICIAN COMPANY SIGNATURE REGISTERED Y N I FEE CURRENY/N Address F License# EC13006186 PLUMBER COMPANY SIGNATURE REGISTERED Ii Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Ii Y/ N FEE CURREN Y I N Address License# I OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address License# �— IIIIIIIIIIIIIIIIIilllllllllillllllllllltlllllllllllllllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;l R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsnarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new'Construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2).sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. 'Directions: I Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW I NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. I UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors. he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply the construction of new buildings,change of use in existing buildings,or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees,las may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the 'Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer'Affairs. If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.'Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. I - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it isi understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of alpermit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) 1 OWNER OR AGENT CONTRACTOR I Subscribed and sworn to(or affirmed)before me this Syy s r' ed and sworn to(9(affir edr9 )before a his by L��bY�lpd�of as/ Who islare personally known to me or has/have produced Who Isla personally known to me or has/have produced DL as identification. DL as identification. Notary Public Notary Public I 4im Commission No. C^ommission Noi 1 i Name of Notary typed,printed or stamped Name of Notary typed,pri = ^d Timothy Coffey My Commission GG 248671 oF � Expires 08/15/2022 i City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Jl 0 D in Date Received: q 1 3 y3 JS10LA h-vlelSite: " ll ' � Y v Sy S Permit Type: in � I 9 0 b o V�7 ,�- Approved w/no comments Approved w/the below comments: ❑ Denied w/the below comments: ❑ i I This comment sheets be kept with the permit and/or plans. SEP� 23z Kalvi witzer--Plans Examiner Date Contractor and/or Homeowner (Rewired when comments are present) i INSTR#2019151252 OR BK9968PG1662 Page 1 of 1 09/06/2019 08:22AM Rcpt 2087807 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk&Comptroller PREPARED BY:ESD HOME SOLUTIONS LLC 7201 BRYAN DAIRY RD LARGO FL 33777 Permit Number Parcel ID Number ^ 11-26-21-0010-214 Q-QJ-40 NOTICE OF COMMENCEMENT State of Florida County of PASCO THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following information is provided In this NOTICE OF COMMENCEMENT. I.Description of property(legal descdpftn), CITY OF ZEPHYRHILLS P13 1 PG 54 EAST 1/2 OF LOTS 14 15&16 BLOCK 214 OR 8872 PG 2632 a)Street(job)Address, ...1-38843 SOUTH 2,Generai description ofimprovements: INSTALL SOLAR PV SYSTEM 3.Owner Information or Lessee information if the Lessee contracted for the improvement: a)Name and address: STRAUGHN EDWARD S&DEBORAH L 38843 SOUTH AVENUE,ZEPHYRHILLS,FL 33542 b)Name and address of fee simple titleholder(if different than Owner listed above) _1 c)Interest In property. 10091. 1 t 4.Contractor Infoffnation a)Name and address: ANDREW HALL-ESD F--S-0jLffl-QNS- 7277f4 4.?571�U-'*'-'—-KQM Li-L.=-j�-ERTY-AN-DAIRY b)Telephone No.: Fax No. (optional) S.Surety(if applicable,a copy of the payment bond is attached) a)Name and address: N/A b)Telephone No.: c)Amount of Bond: 6.Lender WA a)Name and address: b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon whom notices or o i ther documents may be served as provided by Section 713.13(1)(a)7.,Florida Statutes. a)Name and address: N/A b)Telephone No.. Fax No.:(optional) 8.a.ln addition to himself or herself,Owner designates Of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Flodd!a Statutes. b)Phone Number of Person or entity designated by Owner. 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be I year from the date of recording nl sass a different date is specified); 20 WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE-'j CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION i13.113,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT VON YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated iWreln aretrue-to-the best olmy knowledge and belief. naWmaf0wwor Lessee,orOme(sorL-wW.,(AuftrizedOffi0ovD' tarp jr(ne nagar) (Prh Name and Picitirle 57q;w1or,(srd1eA)ffice) The fdregatng instnunent was acknoWedged before me this day o % 20_3_v_43jjf� __ vL by as ....... Q (type of autimrity.ev.officer,trustee,aftmAy m faGI) for as (Name of Person) (typo of authority....e.g.officer,trustoo.allomay in fact) for (name of party orr behalf of whorn instrument was executed)- Personally Known E] Produced ID [9- ^ ;L ) I - Type of ID Notary Signature j.,C "-c.x4z Print name ;:7 7 fUEjqt4GA1D JG-ji3460 EXPIRES:.tune 11.2021 els N SCOPE OF WORK P-121238 THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE RACKED USING A RACKED MODULES IILLLL BE E EL CTRIC D RACKING CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE F) LOCAL UTILITY USING MEANS AND METHODS CONSIS TENT W WITH THE RULES U ES BAY ENFORCED BY THE LOCAL UTILITY AND AREA PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH W ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH }— Z axa APPLICABLE CODES AND REGULATIONS.THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR 0 dam' FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS C 0 W M �u#h Ave South Ave c uIh Ave LISTING AND INSTALLATION INSTRUCTIONS AS WELL AS ALL W W > S suth Ave APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE W W Q INTERPRETED IN A WAY THAT OVERRIDES THEM.I CONTRACTOR IS _ J [CONDITIONS, S AND DETAILS IBLE FOR VERIFICATION OF L IN THIS DOCU O tY W I MENT. IZ < = J PROJECT DETAILS my data cam19 SYSTEM DETAILS 0 PROPERTY OWNER STRAUGHN,EDWARD PLOT NEW GRID-INTERACTIVE LLJ M PROPERTY ADDRESS 38843 SOUTH AVE,ZEPHYRHILLS,FL PV-1 SCALE:NTS DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO 33542 US BATTERY STORAGE Cn Z co APN. DC RATING OF SYSTEM 16,120W M ZONING R;ichiand RESIDENTIAL0 AC RATING OF SYSTEM 12,480W W W USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING ' AC OUTPUT CURRENT 52 OA H = N CLASSIFICATION GROUP(GROUP R3) 52 X ENPHASE IQ7-60-2-US AHJ INVERTER(S) UTILITY COMPANY PROGRESS ENERGY FLORIDA INC Ze#hhilS sY- - North l MODULE AXITEC AC-310MH/120SB (' ELECTRICAL CODE 2014 NEC(NFPA 70) (2)BRANCH OF 13IQ7-60-2-US ARRAY WIRING MICROINVERTERS FIRE CODE 2015 NFPA I ' (2)BRANCH OF 13 IQ7-60-2-US ° Zephyth MICROINVERTERS CONTRACTOR INFORMATION ø � Cy/ZIts rver y INTERCONNECTION DETAILS z As NEW SUPPLY SIDE AC CONNECTION COMPANY BAY AREA PROJECT SOLUTIONS Zhys half POINT OF CONNECTION LICENSE NUMBER S tats PER NEC 705.12D UTILITY SERVICE ADDRESS 2512 BAY FIELD CT,HOLIDAY,FL 120/240V 1cp 34691 + PHONE NUMBER (727)543.3361 CONTRACTOR SIGNATURE �C�ysl;�I�;��� PROJE rdata1sa SUMMARY 2 LOCALE ALL WORK SHALL COMPLY WITH PREVAILING PV-1 SCALE: NTS CODES FLORIDA BUILDING CODE. DOC ID:121238-1514234 NATIONAL ELECTRIC CODE, DATE:8/21/19 AND THE CITY OF ZEPHYRHILLS CREATOR: ORDINANCES REVIEWER: 19 REVISIONS REVIEW ZEPHY CITY OF �NER PLAN EXW PV 1 GENERAL NOTES P-121238 EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHN..L BE INSTALLED IN LOCATIONS SATISFY MINIMUM WORKING CLEARANCES PER NEC T 110.26. �. CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BAY,ARR A 2 BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL LJ.1 EQUIPMENT,CABLES,ADDITIONAL CONDUITS, V RACEWAYS,AND OTHER ACCESSORIES NECESSARY L1.1 FOR A COMPLETE AND OPERATIONAL PV SYSTEM. {— Z Z >- O (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC C/) c ) w ARRAY. °)) F 10 4 (BLACK FRAME,BLACK BACKSSHEET)PV 4°AZIM UTH (w Q M (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY.8:12(34°)SLOPED ROOF,12 PV MODULES (BLACK FRAME,BLACK BACKSHEET),1°AZIMUTH J (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC O OARRAY.8:12(34°)SLOPED ROOF,30 PV MODULES (BLACK FRAME,BLACK BACKSHEET),271°AZIMUTH W M 0 U) = 000 = O M W W N 1 c SITE PLAN PV-2 SCALE: 1"=20' SITE PLAN DOC ID:121238-151423-1 DATE:8121119 CREATOR: REVIEWER: REVISIONS PV-2 GENERAL ELECTRICAL NOTES P-1 21238 PV MODULE PV MODULE MODULES �+ - + PM27 + I + REF. QTY. MAKE AND MODEL PMAx PTC SC IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PM1-261 I MICROINVERTER 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE 3101111 MICROINVERTER 310W PM752 52 AXITEC AC310MW120SB 310W 286W 9.96A 9.47A 40.OV 32.7V -0.t16VPC(-029%I°C) 20A I_ INVERTERS SERVICE ENTRANCE. RATED MAX OUTPUT MAX INPUT MAX INPUT CEC WEIGHTED fr Q4 ( I A Q REF. OTYI MAKE AND MODEL AC VOLTAGE GROUND OCPD RAT POWER CURRENT CURRENT VOLTAGE EFFICIENCY 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. I I 1 I 52 ENPHASE IQ72 US Q Q z4ov UNGROUNDE15.0A 4 97.0% CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS BAY AR A 131N ' 13W $ Q 13 IN 31N 5 B 11-52 60 D - 240W 1.OA 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND + i + i + ;3A PASS-THRU BOXES AND COMBINERS ARTICLE 310.8(D). REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGEaTOROREQUN. 48A24GVAC CONDUCTORS EXPOSED TPteGENERIC GEN-AC-COMBINER OR EQUN. 200A24OVAC 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE SCONNECTS OCPDS 310,8(C), WREF QTY MAKE AND MODEL RATEDCURRENT MAX RATED VOLTAGE REF QTY. RATED CURRENT MAX VOLTAGE W U SWt 1 EATON DG223NR8 OR EQUN. 100A 240VAC 1h1F1I- 4 35A 24OVACzAC COMBINER CBI-2 235A 240 AC4 GROUNDING NOTES c�� _ Fss 2 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THELU F7 F220A 20A C1 r C2 SYSTEM SUMMARY NOTES 1 REQUIREMENTS OF NEC ARTICLES 250&690( BRANCHESI BRA BRA THE DC AND AC CONNECTORS OF THE LISTED UDE DI E ONNE 2 US CONFORM TO NEC PV MODULES SHALL BE GROUNDED TO MOUNTING RAILSLU MIBRANCH 1 BRANCH 2 BRANCH 1 BRANCH 2 69o.17(E)REQUIREMENT THAT INVERTERS INCLUDE DISCONNECTS FROM ALL SOURCESAC COMBINER OFPOWER--_---------CBI l NVFJ2TERSPERBRANCH 13 13 13 13 USING MODULE LUGS OR RACKING INTEGRATE LI r---- PAN1 AC CURRENT 13A 13A 13A 131' MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION.� AC OUTPUT 3,120W 3,120W 3,120W 3,120W CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. r ERATED AC OUTPUT 3,608W 3,608W 3,608W 3,608W ®THEY ARE RODS,OIL RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED 0 = Uj RAY STC POWER 8,060W 8,060W CONDUCTORS OF TYPE THHNITHWN•2 DRYMET AND CERTIFIED TO UL3003 AND UL 9703. -j RAY PTC POWER 7,438W 7,438W THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED USING UL-LISTED LAY-IN LUGS. Q i \J �RRENT 26A CONDUCTOR. INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS Q Q ac POWER OUTPUT 6 24OW 6,240WUNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS.DC BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 C/J W CO ) ( PV SYSTEM DISCONNECT FRAYED Ac POWER OUTPUT 624OW 6,24OW L POSITIVE SHALL BE RED(OR MARKED RED)AND DC NEGATIVE SHALL BE BLACK(OR 3 •GROUNDING AND BONDING"WHEN USED WITH PROPOSED 0 >_ L----------- BRAY STC POWER 16,1zoW MARKED BLACK) PV MODULE. r---------- 5W1 14,877W RAY PTC POWERALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED AS REQUIRED B RRYING ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED W 0 M W 1 AC CURRENT 52A I 3 AC POWER OUTPUT 12,480W METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC (200A MSP W1200A MCB) D 14,431W 250.4(B)AND PART 111 Of NEC ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS 4 FOR THEIR PURPOSE F- = N 7 8 FRAYED AC POWER OUTPUT SHALL BE SIZED ACCORDING TO NEC 690.45.THE GROUNDING ELECTRODE SYSTEM IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A SHALL ADHERE TO 690.47(8)AND 250.169.THE OC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO 250.166 VERIFIABLE GROUNDING ELECTRODE,IT IS THE ( 5 CONTRACTOR'S RESPONSIBILITY TO INSTALL A 2 LOADS AN ADDITIONAL ARRAY GROUNDING ELECTRODE SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTIONS 250.52 AND 250.54 UNLESS THE ARRAY STRUCTURE IS SUITABLE TO SUPPLEMENTAL GROUNDING ELECTRODE. { )- ----------- - AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC) -- SERVE AS A GROUNDING ELECTRODE AS PER NEC SECTION 250.2,THE LOAD SERVED BY THE ARRAY IS INTEGRAL WITH THE ARRAY,OR THE PREMISE'S EXISTING WIRING ELECTRODE IS LOCATED WITHIN 6FT,AS PER NEC SECTION 690.47(D) 6 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG 1HR UT�yM 1 IF BARE WIRE. MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 42 8V AT 1°c(1°c-zs°C)X — EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED -0.116VIC+40.01V=41W). 7 GEC PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE BLADE TYPE DISCONNECT THAT IS ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF A ACCESSIBLE AND LOCKABLE BY THE UTILITY.THE DISCONNECT SHALL BE LOCATED #10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG WITHIN 10 FT OF UTILITY METER SHALL BE USED WHEN EXPOSED TO DAMAGE POINT OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT,AT A GROUNDING AND BONDING CONDUCTORS,IF INSULATED, ®LOCALLY-APPROVED CONNECTION POINT,USING LOCALLY-APPROVED METHODS AND 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF HARDWARE,IN COMPLIANCE WITH NEC 705.12(A). #4AWG OR LARGER CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS CURRENT-CARRYING TEMP.CORR. FILL CONY. M .CURRENT EASE DEBATED TERM. AMP. TERM. TYPICAL CONDUCTOR C,ABLE CONDUIT! AX CONDUCTORS IN OCPD EGC FACTOR FACTOR CURRENT (125%) AMP. AMP. TEMP.RA71NG TEMP.RATING CONDUIT(CABLE B AWG TFIWN•2, 10 AWG Ti, 0.71(56°C) 1.0 26A 323855A 39.05A 75°C 60P1 2 COPPER 0.5°DNA.LFNC 2 35A COPPER 2 1 4 AWG TFFNN-2, P DIA.LFNC 2 WA 4 A O 7HWN-2,PPER 0.96)34'C) 1.0 52A 65A 95A 912A 75°C BSA COPPER 4 AWG THWN-2, 4 AWG THNVN-2' 0.96(34C) 1.0 52A 2A 65A 95A 91 75'C GSA 3 7 COPPER i°DNA.___ 2 70A X 2 COPPER SINGLE-LINE DIAGRAM PROJECT ID: 121238 DATE: 08121119 CREATED BY: SDT CHECKED BY: REVISIONS �-3 SINGLE-LINE DIAGRAM SCALE: NTS PV 3 THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPUANCE WITH ALL APPLICABLE CODES AND REGULATIONS.THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS.INSTALLER SHALL RETAIL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER NSTALLATION MANUALS.NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN AWAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. Cl-AC COMBINER 1 EA� E WHERE ES MAY BE EXPOSED 2 POINT-OF INTERCONNECTION OR AT MAIN SERVICE DISCONNECT(MSP) LABELING NOTES P-121238 ENPHASE Q AGGREGATOR UNGROUNDED O DURING SERVICE.(Cl,C2) O ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC O O AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. LABELS,WARNING(S)AND MARKING SHALL COMPLY POWER TO THIS BUILDING IS ALSO FROM ROOF MOUNTED SIT ARRAYS WITH SAFETY Y DISCONNECTS WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, C2-AC COMBINER SHOWN WARNING,AND CAUTION SIGNS USED THE STANDARD BAY REA HEADER COLORS,HEADER TEXT,AND SAFETY ALERT ENPHASE Q AGGREGATOR SYMBOL ON EACH LABEL.THE ANSI STANDARD 1Q ç) A HEADING THAT IS AT LEAST 50%TALLER ONEC 690.35(F) :` THAN THE BODY TEXT,IN ACCORDANCE WITH NEC W 110.21(B). OEACH DISCONNECTING MEANS FOR A PERMANENT PLAQUE OR DIRECTORY SHALL BE IW- Z SW1-DISCONNECT PHOTOVOLTAIC EQUIPMENT(Cl,C2) INSTALLED PROVIDING THE LOCATION OF THE SERVICE (f) W ON DG223NRB 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC O SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME O O 4 5 7 LOCATION IN ACCORDANCE WITH NEC 690.56(B).WHERE THE INVERTERS ARE REMOTELY LOCATED W M FROM EACH OTHER,A DIRECTORY IN SHALL BE Q PAN1-AC AGGREGATION PANEL INSTALLED AT EACH DC PHOTOVOLTAIC SYSTEM O LL MODEL NOT SPECIFIED) 4 DISCONNECTING MEANS,AT EACH AC DISCONNECTING NEC 690.17(E) MEANS,AND AT THE MAIN SERVICE DISCONNECTING Q ) Cl) O O 9 MEANS SHOWING THE LOCATION OF ALL AC AND DC PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IN Ck7 O J 44 AC DISCONNECT(SW1) THE BUILDING,IN ACCORDANCE WITH NEC 690.4(H). Q W tCl) MSP-MAIN SERVICE PANEL LABEL(S)WITH MARKING,'PHOTOVOLTAIC SYSTEM O a - EQUIPPED WITH RAPID SHUTDOWN,'SHALL BE LOCATED (n Z CO > AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE CO = z 7 5 O O DISCONNECT THE LABEL SHALL HAVE 316'TALL Q M Q. LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A (,j I 0 W RED BACKGROUND H = N NEC 690.54 NEC 690.56(B) U) ANY AC ELECTRICAL PANEL THAT IS FED BY 0 5 AC SOLAR DISCONNECT(SW1) O SEE NOTE NO.5(SW1) 7 BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM(SW1,PAN1,MSP) a Pd + NEC 690.13(B) NEC 690.56(C) AND IFC 605.11.1 NEC 705.12(D)(3) OAC DISCONNECT(CB1 IN PAN1,CB2 IN PAN1) O AC COMBINER PANEL(PAN1) Ir i SAFETY LABELS DOC ID:1212 15142 1 NEC 690.54 NEC 705.12(D)(2)(3)(CJ DATE:8121/19 CREATOR: REVIEWER: REVISIONS PV-4 { www.axitecsoiar.us www.axltecsolar.us ® XITCCO 310 — 320 Wp high quality german solar brand high quality Berman solar brand AX'bl ackpremium HC 310-320W AXlbiackpremnum HC Electrical data(at standard conditions(5TC)irradiance t t 5 at a cell temperature of 25 C) 120 cell monocrystalline Type Nomrr.ai output Nominal vokage N3minaj current Short circuit current ' Open circuit voltage Module conversion High performance solar module Pmpp' tamps lmpp Isc Utx efficiency AC-31O W120SO 310Wp 32.74 V : 9.47A 996A AOO1V 18.66% German engineered—made for America AC 3i5MW120Sb 315 Wp 32.97V 9.56A I0.08A 40.13V 1896% AC-32O''W 12QS6 320 Wp 33.21 V 9.64A 10.I1 A 40.25V 19.26% 15 years manufacturer's warranty Five more years than industry standard Highest module performance through Design lJmJt values Half-Cut-technology and tested materials Fronlaide 9,13 melt(3.2 mm)hardened.low-reflection while gees System voltage 1000 V4C(IL):toe49 VOC(1r ) Cells 120 mont c ys ine high efficiency Madij 1 s TYPE 1(UL 1703) Positive power tolerance from 0-5 Wp Backside Composite `" ex r c(1Ec 81 30) Frame' 1.38 inch(35 mm)black akimirsum frame t4raC7 E14rrimal operating cell temperature)' 45'C K Higher guaranteed yield113 PSF Snow load of up to 113 psf Mechanical data Reverse current feed IR 20.0 Stable module for a long life in extreme conditions L x W x H 65,94 x 39.0&x 1,38 inch(1575 x 992x35 mm) Perntlueibleoperaling Weight 40,791,9(18.5 kg)with frame temperature m 85•C/-4 of to 18SF 100%electroluminescence inspection {No ataenla+9+ s9► rlhenv° Micro crack and hotspot free modules Poway connection to Socket Protection Class iP67 magrtte appliedthemodule) J Axitec-Soft-Grip-Seam aluminum frame Wire 49.3 inch,RWG 11 Whet';AM 1.5; ". Higher stability and easier handling system P»)P67.MC4 Wndapeed1 m/s;Temperature 20'C High quality junction box and connector system for a longer life time $ ______________ Temperature coefficients is Voltage Uoc -029%/i( l = {urr4ilt)Bc {RO4'>6AC Exclusive linear AXITEC high performance guarantee! oulatd roman 8196.3x10) •15 years manufacturer's guarantee on 90%of the nominal performance ° performance x:9s,3 Low-light performance(Example ialAC310W1205)' •25 years manufacturer's guarantee on 85 /°of the nominal II t U crave Curren 1 V+lltage Upp { E O 200 W/rn' 1.90A 32.15V 400W/in' $81A. 3239V 600W 5.68A 32,50V AXITEC►Na 8 800W/In' 7570 3t88V nantY Added Valuer c®us I14E141 /m 9.47 A "' 3274V Y" _e sox 0 859% 85% 1-8°k more power 6o% after 25 years Mocilie» per 30 OVOLTAIC MODULE Module pieces per 760 inch VOLTS)WK4 dk Ox E48750 AN rlaiiatet>a'in 1 5 10 15 20 25 Years OVER 60 Technical data are subject to Marge without Prior 00111w,errors excepted. The r ae8t emms tolerances are+/-396 Data Sheet Enphase Q Cable Accessories Enphase Q Cable Accessories Q AGGREGATOR SPECIFICATIONS Model number Dimensions 190 mm(W)x 227 mm(D)x S0 mm(H)(7.5 in(W)x 9 in(D)x 3.2 in(H)) Enclosure rating h1E pup to 45 from fsatr thta Temperature range -40•C to+55 C(-40'F to+122'F) Compliance ULt7O5, N621O9,iJL87OA �t Enphase Q Aggregator The Enphase Q Aggregator'"and Enphase Q Cable'" Q CABLE SPECIFICATIONS are part of the sixth generation Enphase IQ System'". !Voltage rating � ; 600V(i t�rx€�tftf 2 and Q Cable Accessories These accessories provide simplicity,reliability,and Cable temperature rating 90•C(194 F) faster installation times. Certf ication U13003,DGcablé' Flame test rating FT4 Compliance RoHS.Oft.RE$I CEMV ceslstatflx combtnedtiL for Canada and United States Cable insulator rating THHN/THWN-2 dry/wet Q CABLE TYPES!ORDERING OPTIONS Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q Aggregator Enphase A re at r p gg g Q-12-17-240 250 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 ; • Reduces electrical labor and eliminates wire Q'1220-200 ; 250 VC 23tO(7.Sft) d cape(72'°oefl} ;ZOO nuts for safer,faster installations ENPHASE Q CABLE ACCESSORIES • Aggregates up to three fully populated 20A Name Model Number Description branch circuits €n hie Aggregator Supports solar arrays of up to 11.5 kW with a Q Fitt 1iut4tfite cr�ftutr rbrftes :t�rsxtetitftne'r�an single rooftop aggregator Field-wireable connector(male) Q-CONN-10M Make connections from any Q Aggregator open connector Freftf-wir able connector(female) COQ gE Make connecbons fromanyQ Cable tpen Obnflector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Dnconnec'f tool q if,SG xp Disc t*ootfor.r able connectors,DC connectors,and MmodutF`r mount Q Aggregator sealing caps(male) Q BA CAP 10 Sealing cap for unused aggregator connections Enphase Q Cable Cable seafiitg caps(fginp#) Q-SEAL4O ` tkrtreerialr each u## ed #err, the cabling A . :< Two-wire,double-insulated Enphase 0 Cable Terminator Q-TERM-10 Terminator cap for unused cable ends is 50%lighter than the previous generation Replacement DC Adaptor(MC4) Q Ca I i tv MC4 tntttt voMge 100yp Enphase cable Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) New cable numbering and plug and play connectors speed up installation and simplify -----— wire management TERMINATOR SEALING CAPS unused Link connectors eliminate cable waste Terminatords sold cap cfos oftenunuse cable Sealingr forca a for cable connections in packs often aggregator and connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL CABLE CLIP Field-W ireable Connectors Plan to use at least one per Used to fasten cabling to the racking installation,sold in packs often or to secure looped cabling,sold in Easily connect Q cables on the roof without (Q DISC-10} packs often(Q-CLIP-100), ,IIIIr,- • complex wiring Make connections from any open connector and center feed any section of cable within branch limits Available in male and female connector types To learn more about Enphase offerings,visit enphase.com E N P H A S E. 2017 Enphase Energy.All rights reserved.At trademarks or brands used are the property of Enphase Energy,Inc. ENPHASE. To learn more about Enphase offerings,visit enphase.com > � 2017-04-05 _/ Product compliance: No Data peeaton.com Powering Business Worldwide . ©2016 Eaton. All rights reserved. General Duty Cartridge Fuse Safety Switch DG22 3NRB UPC:782113144252 Dimensions: • Height: 7 IN • Length: 6.42 IN •Width: 8.82 IN Weight:9 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: • Eaton Selling Policy 25-000, one (1)year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product,whichever occurs first. Specifications: • Type: General Duty/Cartridge Fuse •Amperage Rating: 100A • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two-pole • Number Of Wires: Three-wire • Product Category: General Duty Safety Switch • •Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet-DG223NRB Certifications: • UL Listed Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7-6O-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Region:AMERICAS �orrtmonl}ru6edrrlstdulep4lritgs%'®. i- ow'+ iS + SAf ..y. Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maxfmtsminput AC voltage 4ev flV Peak power tracking voltage 27 V 37 V 27V-45V C'per itit}g range 1 'V-48Y 18V-6V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module 1sc) 15 t5 The high-powered smart grid-ready Overvoltage class DC port 11 Ii Enphase AGart bckfeed ctitceixt Enphase IQ 7 M'lcroTM and Enphase IQ 7+Micro PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; IQ 7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 2OA per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter MIcrolnverterS Pealtotttp t{tuwer Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA f Cootxtlnal(L f).�roltag +{Anger d # ' IQ 7+Microinverters integrate with the Enphase fit IQ Envoy",Enphase IQ Battery"',and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15A(208V) 1. 1 A(240V) 1.39A(208V) Enlighten"'monitoring and analysis software. Nominal frequency ° •.. ' Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliabilit AcshotcircultfauttcuiTentover3cye1es 5.8Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and vervolta eclassACport (ii undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor setting7;t1 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85O.85la m 0.85leadin 0.$5_lagging leading... g9 9 g•-• warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V @208 V t�eal(4fficieticy ;: +117 `' , CEC weighted efficiency 97.0% 97.0% 970% 97.0% MECHANICAL DATA Arno ent temperature x ge 40 7o+65eC Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(1076t 2-US&1Q7P ts,yz 2 US)-, t i( additIon knDCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Lightweight and simple Adaptors for modules with MC4 or UTX connectors: Faster installation with improved,lighter two-wire cabling -PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25• Built-in rapid shutdown compliant(NEC 2014&2017) Dimension (WxHx ) 2l intst 175f x 3G.2mtn flhout Weight 1.08 kg(2.38 Ibs) NatWo Productive and Reliable Cooling ' � fans Approved for wet locations Yes • Optimized for high powered 60-cell and 72-cell*modules Pollution degree P03 • More than a million hours of testing Enclosure Class II double-insulated,corrosion resistant polymeric enclosure • Class II double-insulated enclosure Environmental UV exposure rating NEt • UL listed FEATURES Communication POwepLine ... Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy Disconnecting meats TheAC alli?nte tors h ebeest evaluatedJUoc use es the load-7.t • Complies with advanced grid support,voltage and dis mtecti lred rl'4EC 690. frequency ride-through requirements q Y 9 q Compliance CA Rule 21(UL 1741-SA) Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class 8, ICES-0003 Class B, grid requirements CAWCSA-022.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule 21(UL 1741-SA) __ and DC conductors,when installed according manufacturer's instructions. *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at http°'r__/enphase_com/en- /support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. EN PHASE. To learn more about Enphase offerings,visit enphase.com EN PHASE. To learn more about Enphase offerings,visit enphase.com �'� O 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-11-19 Cut Sheet-Rock-It Mount Calsti o 39"X 65"PHOTOVOLTAIC COUPLING ASSEMBLY(CAN __.--.-. --___ _._v-___-__^�___ Engineering I. h13,8e0,tdi to be completed rte aceadeece with n�uFechlrw'e iwROe,,ePealiCaRDna end leefelmtlan 6mh,dj000 CONNECT UP TO 4 ADJACENT 2. see epeD�BB Wmeactmts ner for deteiw n�ariel,f„ a e,dm 9gcre on opbne DESIGNED TO•t*MITO MODULE TYP. MODULES) YP. 4. Do not clo drev,in9s CASTluO ENGINEERING PHOTOVOLTAIC MODULE GENERAL NOTES: RS TRs TRS TRS TT RS +yRSSERVKES,u.c 1.APPLICABLECODE 2017FLORIDABUINGCODE6thED.&ASCE7-10MINIMUMDESIGN LOADS I l I I F I `°""2"'5 FOR BUILDING AND OTHER STRUCTURES. J i 2925 W STATE ROAD 434,surer r r LONGWOOD,R 32779 2.BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE(SYP)WOOD ROOF TRUSS AS EMBEDMENT _____4ou_________o.avtu5" 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, 1 REVISIONS CONSIDERING FROM A 7"TO A MAXIMUM 27"(2/12 TO A MAXIMUM 6/12 PITCH)ROOF IN ® ! DescelPT ON DATE Rev SCHEDULE ALL RESIDENTIAL ROOFS SHALL NOT EXCEED 30'-0"MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND SOLAR SPECS. 2,801n6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. [71.12mm] 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. PORTRAIT MODE 8. ALL IRONRIDGE RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. LANDSCAPE MODE PROJECT DEVELOPER 9.1 CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC:BUILDING CHAPTER [40 1.44m4m m'- -i �" Adjustable Height ; � 16 AND FBGRESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED 3"-4"[75mm-200mmj WIND LATERAL AND UPLIFT FORCES,AND EQUIPMENT DEAD LOADS. lI I I I I 1.20"-2.0"Modules ULTIMATE WIND EXPOSURE B WIND EXPOSURE C WIND EXPOSURE D EMBED. [30mm-50mmj WIND SPEED CLAMP MAX SPAN, CLAMP MAX SPAN, CLAMP MAX SPAN, DEPTH MAX SPAN.SEE SCH. [ V,r(MPH) MAX CANTILEVER MAX CANTILEVER MAX CANTILEVER REQ. MAX PAN.S E SCH. PORTRAIT ARRAY LAYOUT MAX CANT.SEE SCH. ROC -IT 4.0 CLAMP W- tA ST STL sea ASPHALT SHINGLES 16 160 4'-0"O.C.,1'-4"O.C. 2'-0"O.C.,0'-8"O.C. 2'-0"O.C.,0'-8"O.C. 3"* /METAL 5V ROOF TYP. LAG BOLT TYP. SEE SCH FOR MAX SPAN TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN 07m ANDSCAPE ARRAY LAYOUT 3 52.2 5.0Di� 07mm I [127mm] L 160 4'-0"O.C.,1'-4"O.G 4'-0"O.C.,1'-4"O.C. 4'-0"O.C.,1'-4"O.C. 3"* _ S-01 SCALE: 1"-1'-0 OALF'INE I - SCHEDULE REFLECTS COMPONENTS AND CLADDING(C&C)NOMINAL WIND PRESSURES WITH t6 .VT 1 EXPOSURE"B"-"C"-"D",RISK CATEGORY 11,ENCLOSED BUILDING AND h<30'-0"PER ASCE 7-10 TDe Free Ph0„e,.868.7 .4273 i rd F ee Phone ta77.859 394r Meonel S s y 1 { S.Y.P.2X4 LOCATE BETWEEN loeFreeFex,.888.7889984 TOIIFneFa l.688.T68B89e r--- -- "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES"AND 2017 F.B.C.6th ED L.___.,.. -----1. z 7I mz ASG EfS:X * TRUSSES AND NAIL WITH LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. 2-16D NAIL PATTERN AT EACH USE ANTI-SEIZE AND TIGHTEN TO TORQUE PROJECT NAME END TO WOOD TRUSS PER MANUF.INSTRUCTIONS I PHOTOVOLTAIC ASPHALT jREFER TO SCHEDULE FOR I MODULE(TYP) SHINGLES/ jREQUIRED EMBEDMENT DEPTH Io AUK 2 7 201 METAL ILABELED"X"IN THIS DETAIL. I LU INSTALLATION OF MODULES SHALL BE LOCATED IN ROOF WIND ZONE 1. WINDZONE2AND3I ROOFING TYP. REQUIRES SITE SPECIFIC STRUCTURAL ENGINEERS APPROVAL I0 3 2 2 3 ROCK-IT 4.0 CLAMP +----------- - --------------------- FLASHI ASSY TYP. NG(TYP = O O ; ,. GABLE END BUILDING I HIP END BUILDING ROOF ' i I _Z I ROOF WIND AREA ZONES WIND AREA ZONES / � 1 j'/ i I 3 r--------- 2--- ---2------ I 1 O 0 I II ' I < I ASPHALTSHINGLES/METAL5V\\ IWOOD ROOFING TYP.`\ \ 2X PT S.Y.P.WOOD OR ALUMINUM D` _ ,O `\ ` I UNISTRUT CONT.ALONG COLLECTOR SHEATHING �"ST STL LAG BOLT. SEE 16"DIA STEEL ALL-THRD WOOD ROOF SCH FOR EMBED DEPTH SHEET NAME -- --- ` ROD W/NUT- TRUSS TYP. REQ.TYP +------ ---- - - ----- - ---------- WASHERS-LOCTITE s 2 3 ALL NUTS TYP. TYPICAL PV SOLAR ROCK-IT 4.0 4 2 2 ALL CONNECTIONS CONNECTION DETAILSCALE: 1 2"=1'-0" S-01 S-01 S-01 SHEET SIZE TYPICAL PHOTO LTAI RRAY PITCHED ROOF ANSI B 11 " X 17" LAYOUT - WIND ZONES - SCHEDULE - PLAN 1 OPTIONAL SPANNER CONNECTION DETAILS 5 S SCALE NONE S-01 SCALE: 1 2"=1'-0" S-01 SHEET NUMBER S-01 2n<4 Ave 2nd I PEDRO E.CRUZ,PE#75962 AN ENGINEER LICENSED PURSUANT TO •1 46 CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM,ELECTRICAL r >s C g DIRECTORY OF PAGES M M # ~ ' COMPONENTS AND THE SELECTED MOUNTING TO STRUCTURE ARE ' /.�,` -� "t\,�►�3� PV-1 PROJECT LOCATION AND SYSTEM DETAILS DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE !*' N 7fl 2 �w>r FLORIDA BUILDING CODE(FBC)2017 EDITION. _ _ * PV-2 PV ARRAY LAYOUT AND MOUNTING ' STA><EOR ; C PV-3 STRUCTURAL NOTES SCOPE OF WORK r •.OR tO•'@ �' r $ `='r` 1 .ayt,o `••4�► PV-4 ELECTRICAL WIRING DIAGRAM THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM. SOLAR PANELS WLL BE PV-5 ELECTRICAL NOTES RACKED USING A PREENGINEERED RACKING SYSTEM.THE PV-6 FIRE SAFETY PLAN RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH N PV-7 TBD Cr' DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND MODULE DATASHEET PERMITTING JURISDICTION. X ARRAY WIRING BOX DATASHEET p INVERTER DATASHEET South Avenue 14 THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF L W' MOUNTING SYSTEM DATASHEET ✓a DESCRIBING THE'DESIGN OF A PROPOSED PV SYSTEM WITH Q_ ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH Q. MOUNTING SYSTEM APPLICABLE CODES AND REGULATIONS.THE DOCUMENT Q South Ave. South Ave Bout' SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR cr UL 2703 GROUND&BONDING CERTIFICATION FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. . N THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS a ANCHOR DATASHEET LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL TBD 1 STREET VIEW APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE aD $ INTERPRETED IN A WAY THAT OVERRIDES THEM. PV-1 SCALE: NTS CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. PROJECT DETAILS . y C, a PROPERTY OWNER EDWARD STRAUGHN SITE DETAILS 11 `^ ( 0 L I ASHRAE XTRE LOW 1°C 34 F 38843 SOUTH AVE. I u i ° { ° ) PROPERTY ADDRESS ZEPHYRHILLS, FL 33542 I�I ( I"S ASHRAE 2%HIGH 34°C 93°F APN Zelp y°rhi{1 { ) L' CLIMATE DATA SCE ST PETERSBIURG CLEAR ZONING RESIDENTIAL 38843 South Avenue {WIND SPEED 140 MPH ASCE7-10) R EVW DATEMAD USE&OCCUPANCY ONE-OR TWO-FAMILY DWELLING Q RISK CATEGORY II F ZEP I-►y CLASSIFICATION GROUP(GROUP R3) R AHJ CITY OF ZEPHYRHILLS E . 'v '"I� �' � WIND EXPOSURE XAMINER CATEGORY B UTILITY COMPANY PROGRESS ENERGY FLORIDA C AveGROUND SNOW LOAD 0 PSF METER SIN 1482667 ELECTRICAL CODE 2014 NEC(NFPA 70) TES FIRE CODE 2015 NFPA 1 SkydieCyfZHI9 - - s CONTRACTOR INFORMATION FkF I k 4vla�. uoa174 .:_COMPANY ESD HOME SOLUTIONS LICENSE NUMBER CBC1260807 ADDRESS 6076 PARK BLVD N, 2 LOCATION PINELLAS PARK,FL 33781 PV-2 SCALE: NTS LL C PHONE NUMBER (800)425-1175 CONTRACTOR SIGNATURE x } p z a g o a W w N N p o a x LU ITH PREVAILI 9 W O p ODE, N THE CITY OF ZEPHYRHILLS w p 3 , PV-3 SCALE: NTS PV - 1 ' layp:�egy� I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ' O ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND G E Ns••. 4 EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND t ♦ t SEAL ON THIS DRAWING. =*. No 7fl Z II:•1 * *.tp$Ii .'pd GENERAL NOTES EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT S SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED 8 BY A NATIONALLY RECOGNIZED TESTING LABORATORY �! FOR THE INTENDED USE. t3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT,CABLES,ADDITIONAL CONDUITS, RACEWAYS,AND OTHER ACCESSORIES NECESSARY 5 '- FOR A COMPLETE AND OPERATIONAL PV SYSTEM. UTILITY METER VISIBLE,LOCKABLE,LABELED AC DISCONNECT O O AC COMBINER PANEL i O . ® ROADWAY H .. MOUNTING SYSTEM PROPERTIES MODEL UNIRAC SOLAR STACK GEN 4 z BRACKET SOLAR STACK PEDESTAL SOLAR STACK PEDESTAL W/ 'a FASTENING METHOL FOAM ADHESIVE.QTY:4 EA o N MODULE MECHANICAL PROPERTIES MAX. MNT SPACING 1 O.C. d 5 GROUNDING AND INTEGRAL GROUNDING CERTIFIED MODEL AXITEC AC-320MH/120S BONDING TO UL 2703 REQUIREMENTS DIMENSIONS(AREA) 65.9INX39.11NX1.4IN(17.9SQFT) w S WEIGHT 40.8LB >- PV 2 '0 0uai I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY �,e ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND ``�..� C C OA a f p EQUIPMENT DEAD LDS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING. #; Ala 73962 1114 C * Sir= O�;•w mn OIL � ROCK-R 3.0 48'MAX.O.C. ROCK-IT 3.0 } �'S; p�;•� td ON�o ROCK-if 3.0 NOUN! COUPLING ASSEMBLY COUPLING ASSEMBLY � (ttP) ) (ttP) STRUCTURAL NOTES: 1.THIS PLAN MAY BE USED WITH ANY MODULE APPROVED BY AN NRTL (NATIONALLY RECOGNIZED TESTING LABORATORY),AXITEC,CANADIAN SOLAR,SOLAR WORLD AMONG OTHERS. 2.THE SOLAR EQUIMPMENT INSTALLED WILL ADD LESS THAN 4 PSF GRAVITY LOAD TO THE EXISTING N AXITEC -AC STRUCTURE. PANELS TO BE INSTALLED ON ROOF PRESSURE ZONE 1. 32(MIH/120S 3.THERE SHALL BE PV-TO-RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH V (ttP) ROCK-fl 3.0 MOUNT MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL SHARE GROUNDING CLAMPS. (1YP) CONTRACTOR SHALL FURNISH END CLAMPS OF CHOICE. 4.MODULES MAY BE INSTTALLED IN LANDSCAPE OR PORTRAIT ORIENTATION AS PER CONTRACTOR OPTION. 5,MODULES WILL BE ATTACHED TO ROOF USING A ROCK-IT 3.0 RAIL FREE RACKING SYSTEM. AXITEC-AC 6.INSTALLATION METHOD: 320MH/120S a.FIND THE REQUIRED STRUCTURAL ATTACHEMENT POINTS. MARK THESE USING VERTICAL(N-S) O CHALK LINE ON THE CENTER OF THE RAFTERS. CC b.SPACING MAY VARY DEPENDING UPON PROJECT SPECIFIC STRUCTURAL REQUIREMENTS. MAX U SPACING IS 48"FOR PORTRAIT AND 72"FOR LANDSCAPE ORIENTATION. a C.INSTALL ROCK-IT MOUNTS TO PREDETERMINED MOUNT SPACING. ROCK-if 3.0 7.CONTRACTOR SHALL ENSURE CONTINUITY OF ALL METAL PARTS AND CONNECTIONS OF THIS ROCK-ff 3.0 M0UNT1 C0URM Y INSTALLATION TO BE ELECTRICALLY GROUNDED AND BONDED TOGETHER AS REQUIRED. (ttP) (TYP) 8.CONTRACTOR SHALL PROVIDE AW ANY OTHER INFORMATION AS REQUIRED. TYPICAL PORTRAIT LAYOUT 9.DESIGNED AS PER FBC 2017.FLORIDA BUILDING CODE(6TH EDITION). 130(68) ROCK-IT 3.0 MOUNT 3.0 48'MAX.O.C. ROCK-tT 3.0 140 COUPLING ASSEMBLY COUPLING ASSEMBLY 140( ) 150(67) 150 AXffEC-AC j(�) 32OMH/l20S t (ttP) tiI00 49) 140(63) AXffEC - AC 320 1205 120(54) "` Flawa 1 (58) Guam Rico ROCK if 3.0 MOUNT ROCK—if 3.0 TYPICAL LANDSCAPE LAYOUT AASTO WIND MAP (1W) C0UPUNc ASSEMBLr NTS (ttP) Wind 1) Data weld Speed 140,mph Risk Cabagpry II Exposlre B Gust Factor t0.18 "A'DimrnsilxY 3 tt j \ Root'Pressure for Cwnpownu andClsddng w ` Zane 1 1220 psf -19,00 psf lW Zone 2 1220 psf -33.OD psf j \ Zone 3 1220 psf -49.00 psf Z J 3/8'-16 0 3/4_ T IAtl(�f 3.0 S1S1EN x O Flat Roof Hip Roof(7°<0 5 27*) •+° .- J Q N O N w DOSINIG UNOWYMENT '•;L LLI Q Z DOSING ROOF TRUSS i/Y PLYWOOD ® -"�- z Q ? J 11 O of TYPICAL SHINGLE ROOF ATTACHMENT ` U g Nrs Gable Roof(8 5 7°) Gable Roof(7°<0≤45•) :. W 0 cannzmea �•' U ASCE 7-10 COMPONENT&CLADDING WIND PRESSURE ZONES o"o'N0. PV - 3 p{lNtiN C. PV SYSTEM �'�e'•'�'t�w'+°b�'a' ₹w: •W O9t STA' *t'i R ELECTRICAL CONNECTIONS DIAGRAM NOTES: 1. ALL INVERTERS ARE EQUIPPED W/INTERNAL N RAPID SHUTDOWN SYSTEM AS PER NEC 690.12. 2. ALL LINES TO HAVE TERMINATOR AND SEALING CAP INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS. (3)#6 AWG THHN/THWN-2 (3)#6 AWG THHN/THWN-2 o 1"EMT, FMC,PVC, LFMC, LFNMC (1)#8 AWG THHN/THWN-2(EGC) CONDUIT. 1" EMT, FMC,PVC, LFMC, LFNMC � �' { CONDUIT. N L2 Li PV-AC DISCONNECT LOCKABLE FUSED (6)#10 AWG THHN/THWN-2 ENPHASE Q CABLE ENPHASE Q CABLE ME 60A 240V 2-POLE (1)#10 AWG THHN/THWN-2(EGC) (3)CIRCUITS OF L1 &L2 Q-12-10-240 AXITEC 320MH/120S LTER • (1)#6 AWG EGC W/ENPHASE IQ7-60--2-US 60A RK-1 FUSE 3/4 EMT, FMC,PVC, LFMC, LFNMC MICRO INVERTER CONDUIT. { N L2 L1 CAC____ E __ H wU ____ _ _ __ _ __- - I H Lt L1 DC DC L2 L2 NO. 1 NO.16 0 (Q m AC AC DC DC - NEUTRAL NO. 1 N0.16 BONDED TO GROUND NEUTRAL GROUND NO. 1 NO.16T 1- i _____ LL G AC AC DC DC z #6 AWG BARE COPPER NEUTRAL GROUND = GEC TO EXISTING GROUNDING z N g ELECTRODE AC PANEL 150A/240V ENPHASE IQ AC COMBINER PANEL O (3)20A BRK SOLADECK 600V NON-FUSED J Q z (1) 10A BRK FOR IQ ENVOY OR NEMA 3R PVC ROOFTOP �O MONITORING DEVICE JUNCTION BOX o o w w 2 w z O w w I- - cv W zUi 0 U < W f PV-4 it+ Iis7Slfi ;*s 1 O STAN Oi ! j ���i*atiyyO R i V♦d #a,ON� MODULE SPECIFICATION INVERTER SPECIFICATION ELECTRICAL NOTES: a.,,� 1.ALL WORK TO MEET OR EXCEED NEC 2014 REQUIREMENTS MODULE MAKE AXITEC INVERTER MAKE ENPHASE INVERTER MODEL IQ]-6Q-2-US 2.ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT PRESENTED INTHI5 j MODULE MODEL AC-320M1-1/120S INVERTER SHALL COMPLY WITH MANUFACTURERS RECOMMENDATIONS,SPECIFICATIONS AND COMPLY FSEC CERTIFICATION MAX AC POWER OUTPUT 250 VA WITH ALL CODES,STATUTES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING PMAX (STC) 320 W MAX. INPUT VOLTAGE 48 V JURUSDUCTION. VOC (SIC) 40.25 V NOM. DC VOLTAGE ® 240V 240 V 3.INTERCONNECTION VIA SUPPLY SIDE CONNECTION AS PER NEC 705.12(A)USING PARALLEL TAPS IN A NEMA3R VMPP (STC) 33.21 V NOM. AC VOLTAGE 16-48 V BOX(AS REQUIRED)USING NSI IPCS 4002,ILSCO KUP-L-TAP ISULATION PIERCING CONNECTORS,OR ISC (STC) 1011 A MAX. CONTINUOUS OUTPUT CURRENT %,OO A EQUIVALENT. MP (STC) 9.64 A MAX. DC CURRENT 15.0 A 4.PV DISCONECTING MEANS FOR SUPPLY SIDE CONNECTION MUST HAVE NEUTRAL/EGC BOND WITHIN AND NOCT 45 C MAX. DC POWER (STC) 350 W MUST BE LISTED AS"SUITABLE FOR USE AS SERVICE EQUIPMENT'NEC 230.66. N IC ISC 0.04 %/K CEC EFFlCIENCY 97 % 5.ROOFTOP JUNCTION BOX MUST BE MINIMUM NEMA 3R UL LISTED ENCLOSURE. FREE AIR CONDUCTORS MUST w N BE INSTALLED IN RACEWAY OR GUARDED,IF READILY ACCESIBLE AS PER NEC 690.31(A). U c IC VOC -0.2900 %/K a � IC PMPP -0.3900 %/K 6.THE FOLLOWING LABEL IS REQUIRED ON METER CAN AND PANELBOARD:"WARNING:DUAL POWER SUPPLY. v� OPERATING TEMP. -40-+85 C SOURCES:UTILITY GRID AND PV POWER SOURCE ELECTRIC SYSTEM"AS PER NEC 705.12(D)(3). 7.THE PV AC DISCONNECTING MEANS SHALL BE MARKED TO IDENTIFY AS THE:"PV SYSTEM DISCONNECT"AS PER NEC 690.13(B) N AN EMERGENCY CONTACT 8."PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN"LABEL REQUIRED ON PV SYSTEM DISCONNECT MEANS AS PER NEC 690.12(4)&690.56(C). 9."WARNING:ELECTRIC SHOCK HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD ENERGYSOLUTIONS D R E CT SIDE MAY BE ENERGIZED IN THE OPEN POSITION."REQUIRED ON PV SYSTEM DISCONNECTING MEANS AND THE INVERTER AS PER NEC 690.17(E). 1 —800-425— 8 0 O_4 _ 117 10. ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(B). lJ I / 11. ALL COMPONENTS TO BE GROUNDED AS PER NEC 690.43.RA11NG AC VOLTAGE V - LOCATIONS:PV DISCONNECTING MEANS vi LOCATIONS:PV DISCONNECTING MEANS 48A RATED AC LOCATIONS: MAIN PANEL BOARD MAIN PANEL BOARD NOMMNL AC VOLTAGE 240V UTILITY METER CAN AC COMBINER PANEL ZO z LOCATIONS:PV DISCONNECTING MEANS J g W MAIN PANEL BOARD N AC COMBINER PANEL 0 N w w a ~ = W c1 W PV - 5 FIRE SAFETY PLAN GENERAL NOTES ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS =*; N+tsar= �* WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED 3 * 1* OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED � AT STRONG POINTS OF BUILDING CONSTRUCTION,AND ,+ 1. s ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT 3R �r 01 WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, OR SIGNS). (NFPA 1 11.12.2.2.1.3) �".," PHOTOVOLTAIC MODULES SHALL BE LOCATED NO n CLOSER THAN 1-1/2 FEET TO A HIP OR VALLEY IF L MODULES ARE TO BE PLACED ON BOTH SIDES OF THE HIP OR VALLEY.WHERE MODULES ARE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY.(NFPA 1 11.10.2.2.2.1.3) 3 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS THAN 3 FT BELOW THE RIDGE. (NFPA 1 11.10.2.2.2.2) N N ROOF ACCESS POINT WIDE SMOKE-VENTILATION SETBACK,PER NFPA ° 111.10.2.2.2.2 1.5 FT.ACCESS PATH SETBACK, PER NFPA 111102213 ROADWAY __ - w __ __ _____ a ° � O ° 3 = Y W o a g I d a O o w LL W w U- PV - 6 SEAL www.axitecsolar.com www,az[tecsatarcom -AXITCC �; CII C a: 310 - 325 Wp high quality german solar brand high quality german solar brand 1 I iS N O l premium HC AX l premium HC 310-325 Wp a 120 halfceli mortocrytstalline Electrical data(at standard conditions(SIC)irradiance 1000 evatUm',spectrum AM 1,5:at a ce6terrperature of 25'C) I High performance solar module Type Nominal output Hal kck Dosage t4CMn nel c n 42n1 smd C,tud aar.rd 0,ar cacult nu88 . Module atnoemfoil Prnpp Umpp Impp Ise Clod omdw q The advantages: j. AC-31OMH1t20S 310 Wp 32.74 V 9,47 A 9,96A 40,01 V 18.66% AC375Mt1"20S 315 Wp 32.97V 9,56,0 70.03,0 40,13V 18.96% AC-320MH"206 320 Wp 3321 V 9,64 A 10.11.A 40.25 V 19.26% 15 years manufacturer`s warranty AC325MH7t 200 325 Wp 33,45V 9,73A 10.18A 40.37 V 19.56% it Highest module performance through Half-Cut-technology and tested materials oeUmityalodS Frontside 3.2 mm hardened,low-refkwtion while glass System voltage 1000 VDC. Guaranteed positive power tolerance Cells 120 monocrystalkne high efficiency cans NOCT(rromina operating cell ternperaturer 45-C 21( from 0-5 Wp by individual measurement 156,75 mm x 78,38 mm Man load canYarP cePecsy 5400"""' backside Composite film Reverse aarent food IN 20,0 A Frame 35 mm siNar aluminium frame Permissible opera" Maximum 5400 Pa snow load temperature -40'C to 85C i-40F to 165E Mechanical data (No exleme vdlegee.9reater than Uoc 100%electroluminescence inspection L x W x H 1675 x 992 x 35 mm ,be Wed to the nrodutet Weight 18,5 kg with frame -NOCT.inadienoe 800 Whn.AM 1.5: High stability due to AXITEC-Soft-Grip-Seam S Power connection wkld speed 1 mk:Terllperal ue 20•C aluminium frame construction " Socket Protection Class IP68 +�. Wire approx.1.1w.4 mm' High quality junction box • Wag-el system PWglsocket IP68 9 VoAape Uoc -0.29%A( and connector systems • Current Isc 0.04%n( Output PmIV -0.39%A( 542 Exclusive linear AXITEC high performance guarantee' 1.ere8954peefernates(Ex AAW forAC+310120$t 01065:101 i-U cllarectenaltet curve Greaten 1pp Voltage Upp •15 years manufacturer's guarantee on 90%of the nominal performance E Zoo wAna 1,90A 32.15V •25 years manufacturer's guarantee on 85%of the nominal performance LL 400 Whn' 3.81 A 32.39 V 2x00.5 ', a.m,s tl00 W/m' 5.88 A 32,50 V 600 Wan' 7.57 A 92.88 V 1680 W51 9.47 A 3274 V Pechegling Hrm.� 8 1 ® ,' --"rT Adder y 1�1 I Module pieces per pew 30 es% 85% 1-8%more power Module pieces per HC-conlaenar 780 LL eo% en' P after 25 years rn W O tai) 4 0% All dimensions in mm JJ1 i. . 5 F--. 10 .15 20 25 Years fil U Z a Q Technical data are subject to dunge wltlnlut prior notice,errors excepted. The memiumn mbM'anees are N3% . 0- i > • a I i SE `( :,;E.,_ Enphase IQ 7 and 10 7+Microinverters Enphase Microinverters INPUT DATA(DC) 1Q7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings 235 W-350W+ 235W-440W+ t) Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules a Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A- The high-powered smart grid-ready Overvoltage class DC port It II E f pi ease DC port backfeed current 0 A 0 A N O Enphase IQ 7 Micro°'and Enphase IQ 7+Micro" PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; N IQ 7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit O OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter a d achieving the highest system efficiene . --- M#(�+ Q�{.�y p�+ 9 y Y Peak output owes 250 vA 295VA r icroinve a a7 P Maximum continuous output power 240 VA 290 VA art of the Enphase IQ Sy stem,the IQ 7 and N Nominal(L-L)voltage/range' 240 V/ 208 Vi 240 V! 208 Y! 10 7+Microinverters integrate with the Enphase 211-264 V 183-229V 211.264 V 183-229V IQ Envoy'",Enphase IQ Battery'",and the Enphase Maximum continuous output current 1.0 A(240 V) 115A(208V) 1.21 A(240V) 1.39A(208V) Nominal frequency 60 Hz 60 Hz Enlighten'"monitoring and analysis Software. Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms IQ Series Microinverters extend the reliability Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and overvoltage class AC port Ill tit undergo over a million hours of power-on testing, AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading...0.85lagging 0.85 leading...0.85 lagging warranty of up to 25 years- EFFICIENCY @240 V @208' @240 V @208V_ Peak efficiency 976% 97.6% 97.5% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ili Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100° (condensing) Easy to Install Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.38Ibs) Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans • Built-in rapid shutdown compliant(NEC 2014 62017)2017) Approved for wet locations Yes Pollution degree PD3 1 r Enclosure Class it double-insulated,corrosion resistant polymeric enclosure Productive and Reliable Environmental category/UV exposure rating NEMA Type 6/outdoor {1 Optimized for high powered 60-cell and 72-cell*modules FEATURES Communication Power tine Communication(PLC) • More than a million hours of testing Class II double insulated enclosu e Monitoring Enlighten Manager and MyEnlighten monitoring options. • Both options require installation of an Enphase IQ Envoy. • UL listed Disconnecting means The AC and DC connectors have been evaluated and approved try UL for use as the load break disconnect required by NEC 690. - Compliance CA Rule 21(UL 1741-SA) Smart Grid Ready UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class 8, CAN/CSA-C22.2 NO.107.1-01 Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors when installed according manufacturer's instructions Remotely updates to respond to changing . grid requirements • Configurable for varying grid profiles • Meets CA Rule 21(UL 1741-SA) Q JJJ "The IQ 7+Micro is required to support 72-cell modules. t.No enforced DC/AC ratio.See the compatibility calculator at 6ttps:/tenohase coin"en-us/suo aULniodtHe-comoatibiity. • 2.Nominal voltage range can be extended beyond nominal if required by the utility. w U 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 0 lL H EN PHASE To learn more about Enphase offerings,visit enphase.com a EN PHASE. 3 To learn about Enphase offerings,visit eh co a more npase. m �.! j,r ner.'i-Jr t . .n.r.ec �-..:,ih .hose:o4_ .:;,rase!Q F :;asp''J'+,Enphase lq Battery, Cl) I t .d marks f Enphase Enemy,Inc.Data subieci to change 2020-01-06 w f1 o w = I— lx N iij Z > � O SEAL ;pct :eet Enphase IQ Combiner 3 Enphase Networking MODEL NUMBER N IQ Combiner 3 iQ Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade PV U X-i Q-AM 1-240-3 production metering(ANSI C12-20+y-0.5%)and optional*consumption monitoring(+/-2.5%); ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect' CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems upto60 CELLMODEM-01(3G/5-year data plan) microlnverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin islands, CELLMODEM M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring CT Split core current transformers enable whole home consumption metering(+/-2.5%). Ennh3Se The Enphase IQ Combiner 3'"with Enphase CT 200 SPLIT 'C a ipnon mo r io rig required rur Enphaee Storge System, L, IQ Envoy"' consolidates interconnection WirelessUS6adapter Installed at the IQ Envoy For communications withErtphaseEncharge°'storageandEnphase O IQCorn finer COMMS-KIT-01 Enpower"smart switch.IncludesLISScableforconnectiontoIQEn oyorEnphase1OCombiner- 2 Corn le,s equipment into a Single enclosure and and allows redundant wirelesscortmtunicationwithEnchargeandEnpower V Circuit Breakers Supports Eaton 0R210,BR215,OR220,88230,BR240,BR2SO,and 08260 circuit breakers. tl (X-iQ-AM1-240-3) streamlines PV and storage installations by BRK-IOA-2-240 Circuit breaker,2pole,10A,EatonBR210 00 BRK-15A-2-240 Circuit breaker,2 pole,l5A,Eaton BR215 providing a consistent, pre-wired solution for BRK-2OA-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity-one pair residential applications. It offers up to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner3(requiredforEPLC-01) { 2-pole input circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCOY for Combiner 3 ELECTRICAL SPECIFICATIONS busbar assembly. Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max,fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Smart Max.continuous current rating(input from PV) 64 A Includes IQ Envoy for communication Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included¢# fs and control Production Metering CT 200 A solid core pre installed and wired to iQ Envoy Flexible networking supports Wi-Fi, MECHANICAL DATA Ethernet,or cellular Dimensions(W xHxD) 49.5 x 37.5 x 16.8 cm(19.5's 14 75 x 6.63").Height is 21.06"(S3.5 cm with mounting brackets). Optional AC receptacle available for PLC Weight 7.5 kg(16.5lbs) bridge o a a o Ambient temperature range -40 C to+46 C(-40 to 175 F) Provides production metering and optional consumption monitoring Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors Simple • 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output. 10 to 2/0 AWG copper conductors • Reduced size from previous combiner • Neutral and ground: 14to 1/0 copper conductors Centered mounting brackets support single Always follow local code requirements for conductor sizing. • pp g Altitude To 2000 meters(6,560 feet) stud mounting INTERNET CONNECTION OPTIONS Supports back and side conduit entry Integrated Wi-Fi 802.11b/g/n N • Up to four 2-pole branch circuits for 240 VAC plug-in breakers(not included) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Z • 80 A total PV or storage branch circuits Cellular Optional.CELLMODEM-01(3G)orCELLMODEM-03(4G)orCELLMODEM-M1(4G based LTE-M) - (not included) Q COMPLIANCE C) Reliable Compliance,Combiner UL 1741,CAN/CSA C22.2 Ho.107.1,47 CFR,Part 15,CfassB,ICES 003 Production metering:ANSI C12 20 accuracy class 0.5(PV production) r W • Durable NRTL-certified NEMA type Compuance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 N3R enclosure O Z Five-year limited warranty Z W O • UL listed To learn more about Enphase offerings,visit enuhase corn j Q � Dfi � 11:t! 1 '_> > nt �tci? ,n, �.t r iasC go i.�u�.hine 3.a�d other trademarks or serrire names are the EN PHASE ~1Y' : EN PHASE. To learn more about Enphase offerings,visit mWbil e.com �./ ✓ w W X x r;i a w Z O 1 lY l�G Iq. iI SFL D ROCK-IT S�J- STem 3.0 a Snow Load 0-20 psf S�J-STem SPeciFicaTions _fix �s Max No.of Panels 300 Modules per ground lug Materials 300 Series Stainless, Wind Speed Exposure 2:12<Roof Pitch<6:12 r 7:12<Roof Pitch<12:12 tv 6000 Series Aluminum ASCE 7-05 IASCE 7-10 Cabffgory Zone 1 Zone 2 Zone 3 I Zone 1 I Zone 2 Zone 3 tT5 Max System Voltage 1000VDC Coating Black Andodization/Mill Finish SO tpph 110 ntph G,' 114 67 42 Class A fire Rating With UL1703 Type 1 Rated Lug Specifications Bumdy CL50-1 TN Ground Lug D , 96 156 36 `; �V4 , - � N Modules (UL Listing#KDER E9999) 8 146 85 54 (,) Leveling Range 3-4" Ground Wire 14 AWG-4 AWG Copper 90 mph 115 mph C 104 81 38 98 80 80 m Per aboveLugspec. Ground Wire B 88123 5172 32 83 68 68 45 Rock-h SlideCornp Range 3 Max Module Size 64.96'(1650mrn)x 100 mph 125 mph 0 C 68 54 32 N Rock4t Slide Tile 7' 39.05'(992mm)x 2'(50mm) 0 74 43 27 Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45 PSF B 98 57 36 93 76 76 Max Anchor Spacing(3smm/40mm) 72' Rock-it Mount Load Rating 5471bs with Single 5/16'Lag 3.0 110 mph 140 mph C 70 41 26 66 54 54 Max Anchor Spacing(32mm) 48' Safety Factor D 59 34 22 58 48 46 C 61 Skirt Box QTY 6units SlideFasteningHole 5/16'diam 120tt1ph; 160 mph C $! 38 fl 2T 5- � � ,;# �` � ., - - Mount Box QTY 12 units Module Cantilever Maximum cantilever is 1/3 D 61 30 19 Rock-It Slide Box QTY 50 units bracket spacing Notes: -Spacing Governed by Snow Load Coupling Box QTY 12 units Warranty 20 Year Material and Workman- 1.)Values in above table represent the maximum allowable spacing in itches for pullout forces only on EcoFaetee Sol standoff, ship however the designer must round down to meet appropriate rafter spacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72"Codes:National Electric Code,ANSIMFPA 70,NEC 250,NEC 690,IRC,IBC 3.)Maximum allowed standoff capciry=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity Standards:UL 2703:First Edition,UL 1703 5.)Values based on a maximum module width o140' S.)Based on Risk Category 0(ASCE 7-10)structures less than 30 feet in height 'Per the UL2703 Standard:The system should be installed over a fire resistant roof rated for the 7.)Al adjustment factors are set tot.No site specific engineering Is Included in this table application.System components should be periodically re-inspected for loose components,loose 8.)This chart applies to Composition Shingle Installations fasteners,and corrosion such that if found,the affected components are to be immediately replaced.' Snow Load 0-20 psi Wind Speed Exposure 2:12<Roof Pitch<6:12 7:42< oof Pitch<1212 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 FeaTU res 86 mph 110 mph C 65 63 38 2i (1 �11 D' 55 32 20 ! li B 83 49 30 90 mph 115 mph C 59 35 22 56 48 46 • New and improved design • North-South adjustability D 50 29 18 47 36 38 • Fastest,easiest to systemlevel Only one tool required(1/2"deep wellsocket) B 70 4t 26 ;194 on the market 100 mph 126 mph C so 29 48 =441 39 39 Integrated electrical bonding Vertical adjustment of 3" 4" 0 42 26 15 ip 32 32 • SIMPLE-only 5 components B 56 33 20 53 43 43 110 mph 140 mph C 40 23 14 38 31 31 D 34 19 12 32 26 26 B 49 28 18 48 37" 37 120 mph 150 mph C 35 20 12 33 27 ;' o 29 17 10 28 22 .22 Notes: Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFaatett Solar standoff 2.)Maximum allowed spacing approved by EcoF'asten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety 01 1.5 for lag pullout capacity 5.)Values based ova maximum module length of 70" 6.)Based on Risk Category 11(ASCE 7-10)structures less than 30 feet in height 7.)Al adjustment factors are set to 1.No site specific engineering is included in this table O 8.)This chart applies to Composition Shingle installations I- z F LL www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 20 D — www-ecofastensolar.com info@ecofastensolar.com 877-859-3947 8 _J _ a 0 Q () � � U EG.N0 ir SEAL GrounoinG inFormaTion THermaL Expansion anD BonDinG N Therail-free Rock-ltSystem may beusedto mountand ground PV modulesthatcomplywith UL 1703,onlywhen that specific - U module has been evaluated for mound and grounding,in compliance with the included installation instructions. A thermal expansion gap is required per a n9 9 9 � P� P q each continuous 40'length of modules. °"a mot" Note-GroundIng lug must bevisible to Inspectors from the entire perimeterofthe PV array. • Grounding Lug MultI.Use Grounding Pins Omit a coupling and leave a 2"gap in E 9 the Rock It Array Skirt and also between coma mr t ccwFuwing r .vrt� a Grounding pins withinthe MidClamp are multiple use bonding/grounding devices.Moduleswill needto be adjusted ifthe the modules at that point. Rock-ILCoupiing K C4 MidClampsareloosenedtoensurethereis"new"metal to pierce into upon retightening. v a Rock-it Mount d m ++Rock-R Array 5Wrt Grounding Method Rock-It3.0MountbondsN-5rowsofmodules BrackeT SPacInG ® Z Rock-It3.0Coupling bondsE-Wrowsofmodules Portrait Orientation Landscape Orientation Rock-It Array Skirt bonds E-W along the entire array when installed llllllhlllltIkII w )jii One approved ground lug is required per PV array,limited to 300 modules placed in either portrait or landscape orientation. I { I I BonDinG ASsemBLY ano BonDinG PATH I ii r, fI {,mnMm tiµ; - t{ 1 i i Integrated Bonding Maximum east/west bracket spacing is 48 Max east/west bracket spacing iIs72"CC . 32mm modules:Max east/west bracket spacing is 48"OC. ■ : 14 ,E ` n Spacing may vary depending upon project specific structural requirements;i.e.high snow wind load ar£ areas may require lesser spacing E-W than the maximum. sTaGGereD LOUT canTiLever anD OFFSET Staggered Mounting Points l 1. n tai C�4"A (9 b R i l C upin.y, `' I i it u II 0 • Cantilever Maximum cantilever is 1/3 bracket spacing.For portrait Rockft Mount �ock-ItCoupiing a'3 - orientation installatbns,check layout prior to installing ---__—______.___._____.__ ._.._____ _________ -___.__ The array layout instructions in this installation manual offer a z general overview of layout.Periodically,due to a variety of Offset:Offset from all roof edges depends on wind speed,snow rn Z Z factors(roof obstacles,shading,etc.)other layouts are required. loads,local fire and building codes per location 0 f= Z www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 19 J -� www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 18 0 0- OO 0 x j c z I-- w � �