HomeMy WebLinkAbout19-22088 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 22688
BUILDING PERMIT ((/
PERMIT INFORMATION i LOCATION INFORMATION -
Permit Number: 22088 Address: 39309 6TH AVE
Permit Type: COMMERCIAL ZEPHYRHILLS, FL.
Class of Work: ADD/ALT COMMERCIAL Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(sj: Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 12-26-21-002B-00700-0020
Improv. Cost: 37,200.00 i OWNER INFORMATION
Date Issued: 3/23/2020 Narne: IGLESIA EVANGELICA INTL CHURCH
Total Fees: 417.50 Address: 39309 6TH AVE
Amount Paid: 417.50 ZEPHYRHILLS, FL. 33542
Date Paid: 12/06/2019 Phone: (813)404-9329
Work Desc: REMOVE EXISTING TRUSS SYSTEM WITH INSTALLATION REPLACE SYSTEM
CONTRACTORS i APPLICATION FEES
LANTES CONSTRUCTION SERVICES LLC BUILDING FEE 202.50
ELECTRICAL FEE 65.00
PLUMBING FEE 70.00
� ,,�� MECHANICAL FEE 80.00
CIJ�
1
Ins ections Re uired
F ER 2ND ROUGH PLUMB MISC I INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City des and Ordinances. NO OCC6PANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
\$13-780-0020 City of Zephyrhills Permit Alpplication Fax-813-780-0021
7—i4 q Building Department
Received 'yT Phone Contact for Permitting � ' <
Owner's Name ` �eS �hr �v�� u�L, • � �� er Phone Number
Owner's Address 3 !�� Owner Phone Number
Fee Simple Titleholder Name oie Owner Phone Number
Fee Simple Titleholder Address ' �
JOB ADDRESS ' / 53 LOT#
SUBDMSION C;ge PARCEL ID#F_
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED R
NEW CONSTR 8 ADD/ALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR F__1 COMM OTHER
TYPE OF CONSTRUCTION d BLOCK Q FRAME = STEEL =
DESCRIPTION OF WORK 'W L�.GS�Jh /d/�StAw
BUILDING S� F!/ x '�"� SO FOOTAGE -45 HEIGHT
BUILDING $ q�o�v VALUATION OF TOTAL CONSTRUCTION
1, :� I
ELECTRICAL $ i/�pp AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C.
44-PIPLUMBING $ �s od v
2—eA J00I
`l MECHANICAL $ �' VALUATION OF MECHANICAL IN N/J I )/ 0 ,2(C4
=GAS � ROOFING 0 SPECIALTY OTHER 615)�JJi���" 0
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES C.
1 �
I I I I 1
BUILDER COMPANY
SIGNATURE REGISTERED / N FEE CURREP Y/N
Address gal � License#
ELECTRICIAN COMPANY Oyu eQtll � �
SIGNATURE REGISTERED Y/ N FEE CURREN
Address Lipensy
PLUMBER COMPANY /r i/ ` //i�
SIGNATURE REGISTERED / N FEt CURREN YIN
Address License#
MECHANICAL COMPANY ,r/�t��%y! Q (� �c� VI/16
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address I License#
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREK Y/N
Address I License#
111111111111 eeeeeeeeeeeeeeeeeeee1If11111IN11111111111111eeeeeeeeeee1
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working"days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects. 11 commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
AIL t� �f icrs✓L Pwle.-f
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building hnspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contra ors, he is advised to have the contractor(s), sign
portions of the "contractor Block" of this application for which they wil be responsible. If you, as the owner sign as the
contractor,that may.be an indication that he is not properly licensed i nd is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees Od Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the pr9ject does not involve a certificate of occupancy or
final power release, the .fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid priorto permit issuance in accordance Vvith'applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, 1
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I.certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the informa�ion in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be p I rformed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government age" ies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W"unless expressly permitted.
If the fill material is to be used in Flood Zone "Aa, it i understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used.in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area Within the stem wall.
If fill material is to be used in.any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attaI hed permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plag is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing'construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installati r: not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of an�codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months aft r the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RES IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPER IF YOU INTEND TO S_ I N. IN , CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDI YOUR NOTIC O EM T.
FLORIDA JURAT(F.S.117. !, �� ea/
Ime
/OWNER OR AGENT [�/ coT CTOR
bsc b and swo t affirme be re is crib ( r d o e m this
'J by bV
Who is/ar� rso Ily kn to me or has/have produced Wh iis,/a( �erson�lly known to me or'has/have produced �_
` r�t`9� �UJf�! as identification. tl��lC ►tm6e_I as identification. . I' >
/ �'`N�
Notary Public � &A M&I Notary Public
Co mi i Commission No. a
d,printed or stamped m ry typed, d
NotAf 0ublic-sms ofpFleoilda
• - Commission N FF$93967
.•` My Comm.ExpIq;.Jun 24:2020
' #84JI.% Bojided through National Notary Assn.
}
ri WA►W3ai ��YH r
0 '34.t: Rut ar+t,ab3 .!lm,,
.a<<..�ts:f3t�;P.4sif:�'j i4.� �:I:}'t.nt.:; w •'"'�,:;.�t `��
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received:
Site:
Permit Type: �
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/ plans.
Bill Wurjeis—BuildinjWcial Date C actor and/or Homeowner
(Required when comments are present)
f
INSTR#2019206248 OR BK 10016 PG 3602 Page 1 of 1
S/H 12/04/2019 12:12 PiA Rcpt:2114087 Rec: 10.00 DS:0.00 IT:0.00
Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller
NOTICE OF COMMENCEMENT
Permit No.
Tax Folio No. 12-28-214)(1213-007004M
THE UNDERSIGNED hereby gives notice that improvement will be made to cgrtain real properly,and m accordance with
Chapter 713,Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT.
L Description of property(legal description of property):�—°°`°"cowAwLempo}`°'°,"","A"oFynAm'uEmm"EAsraw ai75""O'".S MPIS M
a)Street(job)Address:393W M AVEZEPHYRNILLS,FL 33542-SM I
2.General de Tiptlon of improvement(s):REMO`E EXISTING ROOF,AND INSTALL NEW TRU�ESS,DO INTERIOR PARTIONS,INSTALL NEW AC
I
3.Owner or Lessee information(Lessee as owner only if contracted for improvements)
a.Name and address:IGLESIA EVANGELICA INTLSOLOADOS DELACRUZ DECRISTO INC,39309 slit AVE
b.Interest in properly FUTURE ASSEMBLY
c.Name and address of fee simple titleholder(if other than owner):
4.Contractor Information
a.Name and address: LAZARD ROLAND LANTES,1201 N NEW JERSEY AVE,TAMPA FL,33I07
b.Phone number:S13 3551976 Fax No.(Opt.)
5.Surety Information
•a.Name and address:SOUTHERN SURETY CO,250 E.96th Sheet,Suite 202In&vopo6s,IN 4s240
b.Amount of bond S 500s
c.Phone number:317-87"700 Fax No.(Opt.)
6.Lender
a.Name and address:NONE
b.Phone number:
7.Persons within the State of Florida designated by Owner upon who notices other documents may be served as provided by
Section 713.13(1)(a)7.,Florida Statutes:
a.Name and address: 1AZARD ROLAND LAN IM 1Z1 N NEW JERSEY AVE.TAMPA FL,33W
b.Phone number:813 3551976
8.In addition to himself,Owner designates the following person(s)to receive ay of the Lienor's Notice as provided in
Section 713.130)(b),Florida Statutes:
a.Name and address:
b.Phone number:
Expiration date of notice of commencement(the expiration date is 1 year om the date of recording unless a different
date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE
EXPIRATION OF THE NOTICE OF COMMENCEMENT*CONSIDERED IMPROPER
PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 71 .13,FLORIDA STATUES,AND
CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A
NOTICE OF COMMENCEMENT MUST BE RECORDED�ND POSTED ON THE JOB SITE
BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Verification pursuant to Section 92.52.5,Florida Statutes.Under penalties of perjury,l declare that I have-
read the foregoing and that the facts in it are true to the best of my Itnowledge and belief
Signature of Owner or 's 's Authorized 06cer1Director er/Managw
Signatory's Title/Officer
State of Florida
County of Manatee
The foregoing instrument was acknowledged before me this.Akd- day o ►fir,20A by
All Y '1(,11}.0%}1} ,who is personally known to me or has produced
a 5�0-�oQ-�'Z-1�C� ,and who did/did n It take an oath.
(Driver's License#)
Amanda Collins
NOTARY PUBLIC Puklic-Signature State
Notary
a
STATE OF FLORIDA lie- e of Florida
Corm#GG294573
Expires 1/24/2023 Print,Type,or Stamp
Commissioned Name ofNotaryPublic
. .
STATE OF FLORIDA,COUNTY OF PASCQ
THIS|STD CERTIFY THAT THE FOREGOING IS
TRUE AND CORRECT COPY OF THE DOCUMENT
ON FILE OROF PUBLIC RECORD |N THIS OFFICE
VV\TN SS MY HANDAND OFFICIAL SEAL THIS
FORM R405-2017
RESIDENTIAL ENERGY CONSERVATION CODE bOCUMENTATION CHECKLIST
Florida Department of Business and Prol essional Regulation
Simulated Performance Altemadve(Pe ormance)Method
Applications for compliance with the 2017 Florida Building Code,Energy Conservation via the
residwdW Simulated Pen/ rummice method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida,Energy Code. This form shall include a summary page
indicating home address,a-ratio and the pass or fail status a ang with summary
areas and types of components,whether the home was simulated as a worst-case
orientation,name and version of the compliance software tool,.name of individual
completing the compliance report(i page)and an input surrimary checklist that can
be used for field venfrcation(usually 4 pages(may be greater.
❑ Energy Performance Level(EPL)Display Cana(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Miet/rod:
❑ Air Barrier and Insulation inspection Component Criteria checklist(Table R4o24 i.i-
one page)
❑ A completed Envelope Leakage Test Report(usually one ge)
❑ If Form R405 duct-leakage type indicates anything other than"default leakage;then a completed
Form R405 Duct Leakage Test Report(usually one page}
071240991.09A9 AM EnergyGatipe®-USRGSB v5.1Page i of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY COPE FOR BUILINNG CONSTRUCTION
Florida Department of Business and Prc>fessiona[Reguon_.Rtiderniai Pecfoemancae Method
P*oM re: SGI 39309 Gth Ave Bu&wN�Ume: LLcs i t
swet 3M OW Ave Pennitottice:
` My.~t.r Pamir N ZepharhM FL!=542 Pa 6w. �2�1��
ownm set Jiasdkti4.Rasco$aart &/fbm
Qeop Location: Zepbwhms FL Cowdr-PIasoo.(13anda Oftate Zone 2)
f.New rere>:titrg. Erafg(romPbm) 9. WagTypes{3~it1.1 sgif� Insulation Area
a_-CantmtmB1cetc-lid Iaak8dador R•72 18s5:o0fft
b_t'tarrta-Wood.Adf,arent R=13.0 1461.05 W
3.Numberof units:if indwe twnfly 1 a NIA I R= to
4.Humberof d.WA� Rw. ft2
5, is 0ns a vuorst 10.C.etTing Types om 0 sgft) famdation Area
a.Und#Atfic(vented) E3=30.ti 1t135 00 W
C.conwmxmdsfcorareaabovegrade(fig} 1835 b.Kneewatt(Ver4ed)' t 9oD 51.00ICE
OwWWoneddoorareabelawgrade(ft2) 0 c-N1A R= ft2.
11.Ducts R Itz
Z Wkdms(SI4.3 sgff.) Deem on Area e-Sup,Attic.Ret<Atiie,Aft Corid Spc 6 229
a. ta*actor: Dbl.U=0 3i +4io bs tt2
sHec: SHGc o za
br f!iacfor: Sgf,tf�GS. {7,20 fL2 i^`coarn�g systems kBftm1 ' Empiemy
SHGC: SH6�o 30 a.Gertdtaf.Urnx 54.0 SEFR 14 00
c. t-i=actDr [tbl:U=f.AO. 27.40 ftx
SHGC: SHC".25 13.Fteatireg systems k8bAw EOtcfenW
d. U-Factor: NA ttx a Heat PumP 54,0 HSPF B=
aWe
Arealtlte39htedAveraget)vodwt9Depth: 9.560-it. 14.Hntvrr�tersysterts
Anew Weighted Average'S'ktGt; 0240 a� ,.e
8.FAWTyPW{1835.tf-sgm) frstda§m Awea .
QU tWb0WGretfe�f=daGW R.OA" i895.0o'ft2 b. =rattan fmabu
b.NiA R- fC= Mae
r NIA R= 02 is L`redlt Nolte
GlassFd=Area: o� s Total Prof i t bads: too t4 PASS
Total Baseline Loads: 10-76
I hefty certify that the flans and WoMmftm caveted by .Review of a plans and Q� 3ii 3T.q
this calcrdadiprr are Ea cnmpamm vim the Florida Enew covered by this � £ Off,
Coiie� o «o�, caGcutatioa{ coaslianoe _z,.
Fred van .., , with the Banda Erit:t9l►Grade. „, . -�°r
PREPARM W. � Before tert'strtrction is completed w
DATE: arss�o�xnr this#iat[dat j vain b o inspected far z3
compgancb With,Section Spa
t hereby certify thaithis bwld Florida ores; l
tenth the Horida Err SOD WF
OW0011MAG -.BUILD![ttC;O
:[)AM- - DATE: I
{;gissplimacenwooms Scafthmn bytheakhmmilermftAtanu Ctwernotgeatrbandtereackmw as
per t taCtwysa teQ in accon buce with R40322.1. l
-C art Air Ba<rieraatl fitsul�iion klspedrail dteddr�nn accoe tllltfh R4[IdL0.t.1 and an�
test iitatxordanoe vrith R4t32A.'1.2..
07124"191:09A9 AM EnmWGmrgeO tL-A-FUfts2017 Secffion R4M41 c onvilant sottme Page 1 of 5
FORM,R405-2017
PROJECT
Title*. SCI 39=Oth Ave Bedrooms: Address Type: Sheet Address
Building Type: User Conditioned Area: IM Lot#
owner- sci Total Stories: I BlocklSubDivision:
#of Units: I Worst Case: No PlaiBook:
Bulkw Name: LCS Rotate Angle: a Street: 393g9 Oth Ave
Permit Office: Zopbachms FL Cross Ventilation- County: Pasco
Jurisdiction: Pasco Whole House Fan" City,State,Zip: Zepharhills FL.33542
Family Type:
NewlExisting E=sbMQ:ir0M Plans)
Comment:
CLIMATE
JECC Design Tempi Int Design Tamp Heating Design Da p
Daily Temp
Design Location TMY Site Zone 97.5% 2.6 r. Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 2 39 9 70 75 W.5 64 Medium
BLOCKS
Number Name Area volume
1 Block! 1835. 31214.5
SPACES
Number Name Area Volume 1(itchen Occupants! Bedrooms lnffl ID Anished Cooled Heated
I Cond Spc . -105 312144 70 1 yes Yes yes
FLOORS
V # HoorType Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge InsWatio Cond Spc 356 ft 0 1835 ft2 0.65 O 0.35
ROOF
Roof Gable Root Solar SA Ernitt Emitt Deck Pitch
v # Type Materials Area Area color Absor. Tested Tested Insul. (deg)
I Gable or shad Composition shingles 1835 ft2 M ft2 M4 0.96 No 0.9 No 0 26.6
ATrIC
# Type Ventilation Vent Ratio(I in) Area RBS IRCC
1 Full attic Vented 300 1835 ft2 N N
CEILING
Ceiling Typo Space R-value Ins Type Area Framing Frac Truss Type
I Under Affic(Vented), Cond.Spc 30 Blown 1835 W 0.11 Wood
I
2 Knee Wag(Vented) Cqnd Spc 30 Blown 81 ft2 0.11 Wood
07/2412019 1:09.49 AM EnergyGaugeD USA-FlaRes2017 Section R405.4.1 ComprMnt Software Page 2 of.5
FORM R405-2017
DOORS
# Omt Door Type Space Storrr,s U-Value width Height Area
Ft In Ft In
1 N Wood Pond Spc Non .39 2.7 8 21.6 ft2
2 E Wood Cond Spc Non .39 2.7 8 21.6 112
3 E Wood Cond Spc None .39 2.7 8 21.6 ft2
4 E Wood Cond Spc None .39 2.7 8 21..6 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V/ # Omt ID Frame Panes NFRC U-Factor SHGC Aroa Depth Separrtion Int Shade Screening
1 E 1 Vinyl Low-E Double Yes 0.4 025 16.0 ft2 95 ft 0 In 0.5 ft 0 in None None
2 E 1 Vinyl Single(Clear) Yes 0.65 0.3 24.0 ftz 9.5 ft 0 in 0.5 ft 0 in None None
3 E 2 Vinyl Low-E Double Yes 0.31 023 33.3 ft2 1 ft 0 in 3 ft 0 in None Exterior 5
4 W 7 Vinyl t ov.E Double Yes 0.31 0.23 37.8 ft2 13 ft 0 in 0.2 ft 0 in None Exterior 5
5 NW 8 Vinyl Low-E Double Yes 0.31 023 13.9 ft2 15 ft 0 in 02 ft 0 in None Exterior 5
6 S 9 Vinyl Low-E Double Yes 0.31 023 37.8 IF 20 ft 0 in 02 ft 0 in None Exterior 5
7 SW 10 Vinyl Low-E Doubt- Yes 031 0.23 13.9 ft2 15 ft.0 in 0.2 ft 0 in None Exterior 5
8 W 11 Vinyl LoiwE Double Yes 0.31 023 832 ft2 20 ft 0 in 02 ft 0 in None Exterior 5
9 W 11 Vinyl Single(Clear) Yes 0.65 0.3 21.6 ftz 20 ft 0 in 02 ft 0 in None Norte
10 SW 14 Vinyl Single(Clear) Yes 0.65 0.3 21.6 ft2 15 ft 01n 02 ft 0 in None None
11 E 17 Vinyl Low-E Double Yes 0.31 0.23 22 9 ftz 7.5 it 0 in 02 ft 0 in None Exterior 5
12 E 19 Vinyl Low-E Double Yes 0.31 023 33.3 ft2 1 ft 0 in 0.5 ft 0 m Drapes/btinds Exterior 5
13 E 21 Vinyl Low-E Double Yes 0.4 025 11.4 ftz 1 ft 0 in 0.5 ft 0 in None None
14 S 23 Vinyl Low-E Double Yes 0.31 0.23 18.9 ft2 1 ft 0 in 11 ft 0 in Drapes/blinds Exterior 5
15 W 24 Vinyl Low-E Double Yes 0.31 023 18A ftz 1.3 ft 0 in 0.6 ft 0 in Drapes/blinds Exterior 5
16 S 25 Vinyl Low-E Double Yes 0.31 023 18.9 ft2 1 ft 0 in 2.5 ft 0 in Drapes/blinds Exterior 5
17 W 26 Vinyl Low-E Double Yes 0.31 023 11.4 ft2 1.3 It 0 in 0.5 It 0 in Drapes/blinds Exterior 5
18 W 28 Vinyl Low-E Double Yes 0.31 0.23 18.9 ft2 1.3 ft 0 in 0.5 It 0 in Drapes/blinds Ededor 5
19 S 29 Vinyl Low-E.Double Yes 0.31 0.23 18.9 ft2 3 ft 0 in 02 ft 0 in DrapesJhlinds Exterior 5
20 W 30 Vinyl Low-E_Double Yes 0.31 023 18.9 ft2 1.3 ft 0 In 0.5 ft 0 in Drepeslblinds Exterior 5
21 N 31 Vinyl Law-E Double Yes 0.31 0.23 18.9 ft2 1.3 ft 0 in 0.5 ft 0 in Drapes/btinds Exterior.5
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000418 3875 212.73 00.08 .3138 7
07124120191-09.49'AM EnergyGaugeO USA-F1aRes2017.Section R405. .1 Compliant Software Page 3 of 5
FORM R405-2017
DOORS
# Omt Door Type Space Stomjs U Value W� Height Area
Ft In Ft In
1 N Wood Cond Spc Non(: .39 2.7 8 21.6 ft2
2 E Wood Cond Spo Non$ .39 2.7 8 21.6 ft2
3 E Wood Cond Spc Non,i .39 2.7 8 21.6 ft2
4 E Wood Cond Spe Non, .39 2.7 8 21.6 ft2
WWNDOWS
Orientation shown is the entered,Proposbd orientation.
Wall Overhang
V # Clint ID Frame Panes NFAC U-Facmr SHGC Area Depot Separation int Shade Screening
1 E 1 Vnyi Low-E Double Yes 0.4 0.25 16.0 W 9.5 ft 0 in 0.5 ft 0 in None None
2 E 1 Vinyl Single(Clear) Yes 0.65 0.3 24.0 ft2 9.5 ft 0 in 0.5 ft 0 in None None
3 E 2 Vu yl Low-E Double Yes 0.31 023 33.3 ft2 1 ft 0 in 3 ft 0 In None Exterior 5 .
4 W 7 Vinyl Low-E Double Yes 0.31 023 37.8 f12 13$0 in 0.2 ft 0 In None Exterior 5
5 NW 8 Vinyl Low-E Double Yes 0.31 0.23 13.9 f12 15 ft 0 in 0.2 ft 0 in None Exterior 5
6 S 9 V nyl Low-E Double Yes 0.31 023 37.8 f12 20 ft 0 in 02 ft 0 in None Exterior 5
7 SW 10 Vinyl Law-E Double Yes 031 0.23 13.9 ft2 15 ft 0 in 02 fi 0 in None Exterior 5
8 W 11 Vinyl Low-E Double Yes 0.31 0.23 832 ft2 20 ft 0 M 0.2 ft 0 in None Exterior 5
9 W 11 Vinyl Single(Clear) Yes 0.65 0.3 21.6 112 20 ft 0 in 02 ft 0 in None None
10 SW 14 Vinyl Single(Clear) Yes 0.65 0.3 21.6 112 15 ft 0 in 02 ft 0 in None None
11 E 17 Vinyl Lo wE Double Yes 0.31 023 22.9 ft2 7.51t 0 in 0.2 ft 0 in None Exterior 5
12 E 19 Vinyl Low-E Double Yes 0.31 0.23 33.3 f12 1 ft 0 in 0.5 ft 0 in Dnrpesiblinds Exterior 5
13 E 21 Vinyl Low-E Double Yes 0.4 0.25 11 A J12 1 ft 0 in 0.5 ft 0 in None None
14 S 23 Vinyl Low-E Double Yes 0.31 0.23 18.9 112 1 4 0 in 11 ft 0 M Drapesibliinds Exterior 5
15 W 24 Vinyl t ovwE Double Yes 0.31 023 18.9 ft2 1.3 It 0 in 0.6 ft 0 in DrapesMinds Exterior 5
16 S 25 Vinyl Low-E Double Yes 0.31 0.23 18.9 ft2 1 ft 0 in 2.5 It 0 in Drapes/bllnds Exterior 5
17 W 26 Vinyl Low-E Double Yes 0.31 0.23 11.4 ft2 1.3 ft 0 in 0.5 ft 0 in Dmpes/Mds Exterior.5
18 W 28 Vmyi Low-E Double Yes 0.31 0.23 18.9 ft2 1.3 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 5
19 S 29 Vinyl Low-E Double Yes 0.31 0.23 18.9 IS 3 ft 0 in 02 ft 0 in Dmpeslblinds Exterior 5
20 W 30 Vmyl Low-E Double Yes 0.31 023 18.9 ft2 1.3 ft 0 in 0.5 It 0 in Drapesibliinds Exterior-5
21 N 31 Vinyl Law-E Double Yes 0.31 0.23 1&9 ft2 1.3 It 0 in 0.5 ft 0 in DrapesUnds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
i 728 ft2 384 ft2 60 ft 9.3 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehme Proposed ACH(50) .000418 3875 212.73 4
is 00.08 .3138 7
07124120191:09.49'AM EnergyGaugeO USA-FiaRes2017.Section R405.41 Compliant Software Page 4 of 5
FORM R405-2017
HEATING SYSTEM
# System Type Subtype Effic"teEtcy Capacity Block Ducts
1 A Electric Heat Pump Norte HSPF}8.2 36 kBtu/hr 1 sys#1
1 B Electric Heat Pump None HSPF18.2 18 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
f A Central Unit None SEER:j14 36 kBlu/hr 1080 k4m 0.75 1 sys#1
1 B Central Unit None SEER:�14 18 kBtu/hr 540 drn 0.75 1 sys#1
HOT WATER SYSTEM
i
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric Heat Pump Garage 2.5 65 gat 70 gal 120 deg Nome
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cent # Company Name System Model# � Hector Model# Area Volume FEF
None None fie
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 A Attic 6 477 f12 Attic 119 ft2 Default Le le Cond Spc (Default) (Default) 1 1
1 B Attic 6 229 ft2 Attic 57 1112 Default Leakage Cond Spc (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:N Ceiling Fans:
Cooling Jan Feb Mar W Apr JIMa Jun Jul AugS Oct Nov Dec
[, �� Jain Feb Mar Apr May Jun Feb Mar A' Jul A g Sep A Se OctX Nov Dec
Thermostat Schedule: HERS 20M Reference
Venting
chedule Type 1 2 3 4 5 6 7 7 e 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) PM 68 68 68 68 68 8 68 68 8 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 66 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
07124120191:09:49'AM EwmWGaugeO USA-FtaRes2017 Secdon R405.4. Compf d Software Page 5 of 5
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFOR ANCE IN =92
The.lower the EtzergyPerformance h:lex,the,more efficient the home
1-Newconshuctionore3ftft New(From Plans) 9. WWII types Insulation Area
2. 8ingtefw*ormultiplefa11* Sh4wfaidly a-cootiereteO lock-lot ilk,Emftr -R=xs 1ass,00IF
b:Frame-"Wood,Adiaoent.. R--l" 4S1;05 IF
3. Numbwrof units,if.muftWefamly 1 a MA R= fix
4. Number of Bedrooms to d.MA R= ftz
10.Cali Types Irtstdation Area
5 Is lttis a tuoisf case? NOa,Under Me(Vented) Fir0A 1895A0 fix
B: ConMoned floorarea(W) 1835 b,Knee Walt(Verded) R=30.0 81.00 W
.7 Wfndews" Damon Ama a MA R. IF
x
a, U-factor: Obi i�91 1 419.661IF 11 a.Sap:Aft,Reti Attic,Alt Cond Spe s 229
SHGC: S14MO28
b. U-Factor. %I,,U=OAS 67.20 W
SHGC: SNC"=0.30 12 Coo ft syste"ms kBk ter Efficiency
a U-Factor. Obi,U=OAo 27AD ftz a:eer&W Unit 44,o SEER:14.00
r.
SHGC: StiGC=025
d. U-Factor. NIA ft2 M Heati systems kBkft Efficiency
SHGC: a.Electric Heat Pump 54.0 NSPF-820
AreaftoledAverageOmtkan Depth: 9M6 n
AreatYYeightedAverdge SHGC: 0240
ti_ Poor-Types insulation Area 14.fiotwater systems Cap:65 gallons
a_Sheds Grates Edge lrrsdation R=0.O 18M.00 IF a-��c ER 2.5
r~MA l b. Con i rva*m features
None
15.Credt'ts. Norte l cerlify#hat this home has complied-vo th the Florida Energy Efficiency-Code�for Building qAE S�
Consttvietion through the above energy saving features which
win be installed(or-exceeded) Q =��0
in this home before Anal inspection: Otheridse,a new EPL.Display Card be completed
based on installed Code c for mront features " N,Q
AtN
Builder Signature: Date: I ' a
Address of New Home: CitylFL Zip: A ►
Boa wi;'�`�
'Note: This is not a Building Energy Rating. If.your"index is below 70, home may quality for energy efficient
mortgage.(EBA)incentives if you obtain a.Rorida EnergyGauge Rating. ffte EnetgyGauge Hotline at(321)
638-1492 or see the-EnergyGauge web site at energygauge com for information and a 5st of cerlified Raters. For
information"a bout the Florida Building"Code,Energy ConservMon,contact the Florida Building Commission's support
staff.
**Label required by Sion R303.1.3 of the Rorida Building Code,Energy Conservation,if not DEFAULT-
07124MIO 1:09A9 AM Bmqjy USA-FiaRes2047 Section R4M41. Pagel 1 of 1
FORM R405-2017
Florida Department of Business and Professional Regulations
Residential Whole Building Performance hand Prescriptive Methods
I
ADDRESS* 3=1 601 Ave Permit Nurer:
2eptrathitts FL,33542
MANDATORY REQUIREMENTS See individual code sections fo full details.
401.3 Energy Performance Level(EPL)display card(Mandatory). The buildog offidal shag require that an energy Performance level(EPL)
display card be completed and certified by the builder to be accurate and correct beC+final approval of the building for occupancy.Florida law
(Section 553M86,Florida Statues]requires the EPL display card to be Included as an addendum to each sales oonbract for both.presold and
nonpresold residential buildings.The EPL display card contains information Indicating the energy performance level and efficiencies of components
Installed in a dwelling unit.The building official shag verify that the EPL display card completed and signed by the builder accurately mffecls the plans
and specifications submitted to demonstrate compliance for the building.A copy of`h!' EPL display card can be found in Appendirx C.
E3 R402A Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402-4A.
• R402.43 Building thermal envelope. The building thermal envelope shall comply with Sections R402A.1.1 and R402.4.1 2-The
sealing methods between dissunitar mattenals shelf allow for cfifferentiat expansion and contraction.
, R402.40.1 Installation. 'the components of the building thermal umnvebpe as listed in Table R402.4.1.1 shall be installed In
accordance with the manufacturees Instructions and the afteria listed in Table 402A.1.1,as applicablo to the method of construction.
Where required by the code official,an approved third party shall insp-c!all components and verify compliance,
" R402A.1.2 Testing. The building or dwelling unit shaft be tested an,J verified as having an air leakage rate of not exceeding 6 air
changes per hour in Climate Zones 11 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0-2 Inches w.g.(50 Pascals).Where r by the code official,testing shag be conducted by an
approved third party.A written report of the results of the tea shag be signed by the party conducting the test and provided to the code
Official.Testing shall be performed at-any time after creation of all ponsiations of the building thermal envelope-
During testing: I
1.Exterior windows and doors,fireplaoe and stave doors shall be dos ,but not sealed,beyond the Intended weatherstr[Whg or
other Infiltration control measures;
2-Dampers including exhaust,Wake,makeup air,backdraft and flue 4 lampers shall be closed,but not sealed beyond Wended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
S.Healing and cooling systems,9 Installed at the time of the test,shag be turned oft and
0.Supply and return registers,it installed at the time of the test,shall be fully open.
• R40ZAL2 Fireplaces.Now wood-burning fireplaces shall have fight-fitting ffule dampers and outdoor combustion air.
0 R402A.3 Fenestration air Ileakage.11%findow%skylights and sliding glass dears shall have an air infiltration rate of no more than 0.3 elm
per square toot(1.5 L/sOm2),and swinging doors no more than 0.5 chn per square W(2.6 lds(m2),when tested according to NFRO 400 or
AAL"DMAAGSA 101/1.SMA440 by an accredited,Independent laboratory and listed and tabeled by the manufacturer,
Exception: Site-bunt windows,skylights and doors.
0 R4024A Recessed fighting. Recessed luminaires installed in the buldij,thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces*Ali recessed luminaires shq be IC-rated arid labeled as having an air leakage rate not
mom than 2.0 cfrn(0.944 Lis)when tested in accordance with ASIM E 283 at a 1.57 psi(75 Pa)pressure differential.An recessed
luminaires shall be sealed with a gasket or caulk between the housing and 1 Interiorwaft orcelfingcoveting.
C1 R403-1.1 T henlrwdall provision(Mandatory). At least one thermostat shall be praidid for each separate heating and cooling system.
a
R4MI3 Heat pump supplementay heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
th8L.ex0ept during defrost,Prevent supplemental heal operation when the heat pump c I 6mpwmr can meet the heating load .
0 R40322 Sealing(Mandatori)AH ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
withrSectlon-C403Z72 of the Commercial Provisions of this code and shall be shown mget;ducltlgW "eczftedabypost-construcgon
or roughwin testing below I`
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by ertfter an energy rater certified In accordance with Section
553—q%Florida Statutes.or as authofted by Rovida Statutes,to be"substantially leak f fee"by either of the following.
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113" in)per 100 square feel(929 m2)of conditioned floor area
when tested at a pressure differential of 0-1 Inches w.g.(25 Pa)across the entire 1 tam,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the feet.
2. Rough-In test Total leakage shall beless than or equal to 4 cftn(113 L/Imin)per 00 square feet(9.29 m2)of conditioned flow area when tested
T
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,inducting the manulacturees air handler enclosure.Ali registers shag be
taped or otherwise sealed during the test If the air handler is not installed at the time of the test,total leakage shag be loss than or equal to 3.cfm
(85 Onin)per 100 square few(9"m2)of conditioned u=area.
Exceptions:
1. The total leakage test is not required for ducts and air tku-4srs located Ong within the building envelope.
2. Duct testing Is not mandatory for buildings complying by Section R405 of this
0712412019 1.09.419 AM EnergyGaugeO USA-FlaRes2017 Section R405 4.1 Compliant Software Page 1 of 3
FORM R405-2017
MANDATORY REQUIREMENTS- (Continued)
❑ R40&2.3 Building Cavities(Mandatory).Building framing cavities shall not be as ducts or plenums.
❑ R4W2 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 5YF(13'C)shall be insulated to a minimum of
R403.3.1 Protection of piping insulation.
❑ R403A.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hotivater circulating pump when ttte system is not in use.
❑ R403 A.3 Heat traps(Mandatory)_ Storage water heaters not equipped with intogral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'h inches(89 mm)in the hot water disiribution line and cold water line located as close as possible
to the storage tank.
❑ ii403AA Water heater efficiencies(Mandatory).
0 RMAAA Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shalt be equipped with automatic temperature controls
capable of adjustment from fhe lowest to the highest acceptable temperature seftittgs for the intended use.The minimum
temperature setting range shall be from 100°F to 140'F(36°C to 60°C).
• R403AA.12 Shutdown. A separate switch or a toady marked circuit nit breaker shall he provided to permit the power supplied
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heaf calegwy. Solar water heaters shall met the criteria Section MMA.4 91.
R403AA2-1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south'.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the re"irements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable)or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that dose when the ventilation system Is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
0 R403ALI Equipment siting. Heating and cooling equipment shall be sited in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and coaling calculation methodologies,
based on building toads for the directional orientation of the building.The manufacturer and model number of the outdoor and
Indoor units(ii split system)shag be submitted along with the sensible and total cooling capacities at the design conditions
described in Section f1302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 COOHRg equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturers product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
07/24/2019 1:09AS AM EnergyGauge®t1SA-FlaRes2017.Section R405 4.1 Compliant Software Page 2 of 3
FORM"R405-2017
MANDATORY REQUIREMENTS- (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published r AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded perforrrr ce:d=, shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment This selection sh I based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipin t�,.the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value toy entering dry bulb temperature.
Design values for entering.wet bulb and dry bulb temperature shall be for indoor dry bub and relative tumidity used for the load
calculation and shall be adjusted for return side gams if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multifamily residential equipment sizikc 1 may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of at load.
2. When signed and sealed by a Florida-registered engineer,in'attached single-and multifamily units,the capacity of
equipment may be sized in accordance with good design praMice_
O R403.6.12 gating equipment rapacity
• R403.6.12.1 Heat pumps. Heat pumps sizing shall bs based on cooling requirements as calculated according to Section
R403AA.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling bad.
• R40&6.122 Electric resistance furnaces. Electric resistance fu Itnaces shall be sized within 4 kW of the design
requirements:calculated according to the procedure selected in Section R403.6.1_
R403.6.1.2:3 Fossil fuel heating equipment. The capacity of-"I fuel heating equipment with natural draft atmospheric burners
shall not be less than the design bad calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such"as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space coaling or heating within that space by one or made of the following options:
1. A.separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2 A variable rapacity system sized for optimum performance during base load periods is utlized.
O R41M7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
O R4032 Snow merit system controls(Mandatory). Snow and ice-melting systems supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement'temperature is above 55*F,and no precipitation is failing
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
R403.9 Swimming pools,in-ground spa 'and portable spas(Mandatory).- The energy requirements for residential pools and
ingreund spas shall be as specified in Sections R403.9.1 through R403.9.3 and in a rdance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R40SAI tool and spa heaters. All pool heaters shall be equipped with readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
1i403.9.1.1 Can and oltdired pool and spa heaters. All gas and."red pool and space heaters shall have a minimu m
thermal efficiency of 02 percent for heaters manufactured on or after April 16,203 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuous)i bu rninq pilot fights.
R403.9.12 Heat pump pool heaters. Heat pump pool heaters shill have a minimum COP of 4.0 when tested in accordance
with AHR11160,Table 2,Standard.Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compiiarhce.Geothermal swimming pout h6at pumps are not required to-meet this standard.
O R403.9.2 Time switches. rime switches or other control method that can automatic ally turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps_Heaters,pum and motors that have built in timers shall be deemed in
compliance with this equipment
Exceptions:
1. Where public health standards require 24-hour pump operatio
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-she renewrableigeneration.
O R403.9.3 Covers. Heated swimmng pools and iriground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat W .
Exception: Outdoor pools deriving over 70 percent of the energy for I eating from site4ecovered energy,such as a heat pump or
solar energy source computed over an operating season.
0 RR404.1 Lighting equipment(Mandatory-). A minimum of 75 percent of the lamps in permanently installed fighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed fighting fixture shall contain only high efficacy lamps.
Exception:- Low-voltage fighting shall not be required.to utilize high cy lamps.
0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have eantinueusly burning pilot tights
O R40:2 Performance;ONLY. All duds not entirety inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance-ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and bears type or
concrete deck roofs do not have suffecem space,R-10 is allowed.
0724120191:09:49'AM EnergyGauge®USA-F1aRes2017.Section R405.4.1 Comprranrt Software Page 3 of 3
v
FORM R405-2017 TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SCI 39309®th Ave Build Name: LCS
Street: 39309 Gth Ave Permit Office: Zephertufs FL
City,State,Tip: Zepharhills FL,33542 Permit Number.
Owner. SCI Jurisdiction: Pasco
Design Location: Zepharhilis FL
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installeii in the building envelope.
Exterior thermal envelope contains a corlitinuous barrier.
Breaks or joints in the air barrier shall bed sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/atfic The air barrier in any dropped ceiling/so d shall be aligned with the
rty insulation and a gaps in the air barriershall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for f amed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows,skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawispace walls.
Exposed earth in unvented crawl spaces hall be covered with a Class I
vapor retarder with overlapping joints tapgd.
Shafts,penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,'or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
airtight IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the Showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air seated boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An alr barrier shall be installed on fireplac6 walls.Fireplaces shall have
gasketed doors I
07/24/2019 1:09:49 AM EnergyGaugeO USA-FlaRes2017.Section R405.4.1 Compliant Software Page 1 of 1
CITY OF / / / / BUILDING
ZEPHYRHILLSN OT I C E
DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT - •
ADDRESS TE\ PERMIT,
_1V5
THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job
will be accepted.
S2 5 ` �
rf-I 4_,,, AAW &V-XV
1
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AF�ER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 F R R -INSPECTION
or other material,until the proper inspector has had ample time to approve
the installation.
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI.
INSPEC OR