Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-22223
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22223 FIRE ALARM SYSTEM PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 22223/22120 Address: 38421 5TH AVE Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-15300-0130 Improv. Cost: 5,800.00 OWNER INFORMATION Date Issued: 3/18/2020 Name: FRATERNAL ORDER OF EAGLE Total Fees: 150.00 Address: 4149 NEW RIVER RD Amount Paid: 150.00 ZEPHYRHILLS, FL 33542 Date Paid: 3/18/2020 Phone: (989)284-3406 Work Desc: INSTALLATION FIRE ALARM FRATERNAL ORDER OF EAGLE CONTRACTORS APPLICATION FEES FLORIDA FIRE SERVICE ING FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 50.00 Ins ections e - ire FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME MENT " row— twj�� N RACTOR SIGNATURE PERMIT OFFIC PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application /I Date Received F Phone Contact for Permit Owners Name C-(Z t' t°L VF i' y� 't`i p� �/Owner's Phone Num Owner Address ber 's F�.� r/ - - Z_;i 1 � LL ":5L` 33 s Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address J6 A-V C 4 .L Gr ►'Ll LL Sry Q Lot# Sub Division Parcel# Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum Hood Installation 0 Emergency Generator<30 kw LP/Natural Gas-Instailator Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sate Fire Protection Maintenance-ANNUAL E-1 Places of Assembly-ANNUAL PRO We-m—, er Sprinkler ❑ ❑ 0 ® Recreational Burn Fire Alarm ❑ ❑ ❑ Sparklers Hood Cleaning ❑ ❑ ❑ Sprinkler System Installations Hood Suppression ❑ ❑ ❑ Standpipes(Sprinkler Sys) Fire Alarm Installation Torch Roofing/Tar K Fire Pumps WasteXoe Storage ANNUAL R Flammable Application-ANNUAL nation of Project Fuel Tanks Q Other: Contractor Company /p.^ G �i 1t;C��c ry t K � Signature C Registered g N J Fee Current I MI N Address License# �0_` "g ELECTRICIANJ Company Signature Registered Y/N Fee Current Address License# PLUMBER Company Signature Registered Y/N Fee Current Address License# MECHANICAL Company _ Signature Registered Y/N Fee Current Address License# OTHER Company Signature Registered I Y/N Fee Current Y/N Address License# Directions: _ f Fitt out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$50001, Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(hftp:flapprelser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by |am\ both the owner and contractor may be odad fora misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthennore, if the owner has hired m contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. |f you, ao the owner sign aothe contractor, that may baan indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713° Florida Statutes,asmmmended): |f valuation of work ia$2.5OO.00or more, | certify that /, the app|icant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. |f the applicant iosomeone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver}tbn the^owner"prior to commencement. - CONTRACTOR'S/OWNER`S AFFIDAVIT: | certify that all the information in this application |a accurate and that all work will he done in compliance with all applicable laws regulating oonetnundon, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. |certdy that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility 1:6 identify what actions I must take tobeincompliance. |f| am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior tocommencing construction. I understand that a separate permit may be required for electrical xm/dk, p|umtdng, signa, weUa, pon|o, air conditioning, gas, or other installations not specifically included in the application. /\ permit issued shall ba construed hobea license to proceed with the work and not an authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within mix months of permit issuance, no if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in whUng, from the Building Qffinia| for m period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this 4scrib d nd swoKrfakQr affirmed)before me this Who is/are personally known to me or has/have produced WAo is7dre personally known to _""i1lasfhave VroTu—ced asidentificatfon. as identification. Notary Public Z4", Notary Public Commission Commission No. wo�� ZEPHYRHIL4S FIRE DEPARTMENT 38410 6th Ave Zephyrhills, FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy No.: Plan No.: Contractor: Business Name: Billing Address: Business.Address: Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact:' Contact: PLAN REVIEW FEES INSPECTION FEES , PERMIT FEE .Annual- Education,healthcare,De tention&Correctional Public Assembly,Business, schools, Storage,Mercantile and Churches Site Plan N/C Industrial. no charge Sprinkler $50 Multi-Family/Commercial :03 sf up to 800 sq ft $ 24.00 Standpipes $50 (Minimum Charge$24.00- 801-1,500 sq ft $ 34.52 Fire Pump $50 I Plan Revisions DBL. 1,501-2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 0-.25-Heads $50 51-501-7,500 sq ft $ -187.52 Natural Gas $50 26:plus;Heads $100 7,501-10,'000 sq ft $ 262.52 Fuel Tanks- pertank $50 ®'. STANDPIPE.SYSTEM ' 10.001-15,000 sq ft $ 375.02 Sparklers $100 Per.Rlser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation' $25 11:Per Pump $100 30,00140,000 sq ft $ 1.050.02 Controlled Bum(15da; $100 FIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,600.02 Hood/Duct $50 rat 0-25 Devices $50 60,001-80,000 sq ft $ 21100.02 Place of Assembly $50 Annual 80,001-($2,100.02)per 26 plus.Devices $100 ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS (Business closed until Flammable Application $50 Annual Wet $50 Hviolations corrected) Waste Tire Storage $50 Annual Dry $50 SPRINKLER SYSTEMS Generator<KW $100 CO2 $50 ;Hydro Undergrounds $45 Generator>30 KW $100 Other $50. :.Hydrostatic Test, $65 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Acceptance Test $45 per system Fumigation Tenting $50 Hood/D.ucts $50 Hydrant'Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50 Annual LP Installation pertank $50 FIRE ALARM SYSTEM F..uel,Tank Installation $50. System Acceptance $50 (Per Tank) $50 Lj Recall Acceptance $50 Natural'Gas Installation $50 OTHER (Per SysterT) .Flre Wall/Smoke Wall $15 per wall Spray Booth $50 'LP Gas $25 pertank Natural Gas $25 per system Tent 10'x10'or greater $15 per lent Fire Pump $45 Fire Suppression $30 System Acceptance ,.Exhaust Hood/Duct $30 Re-Inspection DBL :(other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS TOTAL s a. INSPECTION TOTAL PERMIT TOTAL GRAND TOTAL a Comments: Date: .-z - .Inspector: see back nlh `=�rs"aF=J.�[.:'Y'"':'�+i;?".5;.-,'F*';.a""`y f",.P.,.-�:%-�a^...-;•'�--.-:z,:w•r-�ts�Y'a.�'?",-:.-,:=:�:..u9^:.,:.r.7c:.[;.:-'�'�'::-sh.utnss•.s.^:rc�s.•x:.�+:-,s�:x:•�..a+�-r,e�.=rxr:.,scxa�:.®-�..�:.-�:.e>.. r.a.-�..--c...._....,....,-y..,._......,......_....�..-..-_. Y3 y t FALSE ALARM FEE 1stAlarm N/C 2nd Alarm N/C 3rd Alarm -N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 Cont.-Annual Inspection Fees 3-11 Units price per unit $ 5.36 12-25'Units price per unit $ 4.82 26-50 Units price per unit $ 4.29 51.100 Units price per unit $ 3.75 100 or more Units price per unit $ 2.68 Fire Safety re-inspectiaWAypes First Re4nspectioi N/C- Second re-inspect • $75 Third re-inspectior $ 125:00 Inspectiontscheduled butcancelled-24 hrs $ 50.00 TOTAL- JOh City of 2eplyrhills BUILDING PLAN REVIEW COMMENTS ('" , l Contractor/Homeowner: � �i �'( � fiyt S� YV f ce_ 'Ttn n- Date Received: h� Site: 3), U� Permit Type: i2 Approved Who comments:E�_ / Approved w/the below comments: D Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. _ffir—Plans Examiner at Contractor and/or Homeowner ��{_ 60 ,-Y) (Required when comments are present) . Y 5 FRATERNAL ORDER OF EAGLES SubmftWsfor: New Fire Marm System _ ��r.a's=;wry yry". S:� {.� ��� 5, T = 'S�,tir-.��aY.'' �70.• �,.,dl®,•�.;.,din�.M�q � Uil "lid fEkd�d94'FL'�D$1 MZ �. - .,.'!*y,. � ..cake»�, �r, �' •jJ rw`ya2"�'r Prepared by: Daniel Glenn LIC EF20001011 LVU406049 NICET110843 r Small Building Fire Alarm Solutions Klade4 I.' wow Technology that saves lives �4 IIIit Fireya Alan S;Y t E-)M S Fm : :k F tl VS 1 , VS4 Y 1.Y � FDN- - �,p` NY 29 �;�. '•..£;,..;?n Al}ai,...t 7165-1657: . 0244 S3000 Overview Features Kidde brand intelligent life'safety systems offer the power of high- • Auto-programming speeds installation time end intelligent processing in configurations that deliver uncompli- . Supports V-Series intelligent modules and detectors cated solutions for small to mid-sized applications.With intelligent detection,electronic addressing,automatic device mapping, 9 Form C contacts for alarm and trouble, Form A for supervisory optional EthernetO connectivity,and a full line of easily-configured • Electronic addressing with automatic device mapping option cards and modules,these flexible systems offer versatility . Optional Ethernet,port for diagnostics, programming and a that benefits building owners and contractors alike. variety of system reports The VS1 provides one Class A or Class B intelligent device loop . Two programmable switches with LEDs and custom labeling that supports up to 64 device addresses,and two Class B Notifi- cation Appliance Circuits(NACs).Optional Class A device wiring is Supports Genesis horn silence over two wires,and UL 1971-compliant strobe synchronization available with the use of a module. The VS4 provides one Class A or Class B intelligent device • Supports GSA-REL releasing module for fire suppression loop that supports up to 250 device addresses. Loop controller • Class B or Class A wiring modules may be added in combination to expand total system . Ground fault detection by module capacity in 250-point increments to up to 1,000 device addresses. VS4 panels include four NACs that may be wired for either Class A Supports up to eight serial annunciators, (LCD, LED only,and or Class B operation. graphic interface) Can use existing wiring for most retrofit applications The RZ116-2 module adds even more capacity to VS installations by adding up to 16 conventional device circuits and two additional • Upload/download remotely or locally notification appliance circuits.This makes them ideal retrofit solu- • Two-level maintenance alert reporting tions that can accommodate new intelligent detectors,as well as • Pre-alarm and alarm verification by point existing conventional devices. • Adjustable detector sensitivity VS Series supports a wide range of high-end features,including: 4 x 20 character backlit LCD display • Intelligent modules,detectors,and bases Optional earthquake hardening:seismic Importance Factor 1.5 • GSA-REL Releasing Modules • R-Series remote annunciators • Standalone operation • Integrated Carbon Monoxide gas sensing with V-PCOS de- • Transmission test frequency by hour tectors including distinct audible signaling • Alarm ON command manually activates alarm condition Page f of 8 O A A A S I i e §,;,i_ V85005-0135 11oi to t;,, ,....., ;ur ,rc:, .t':x:£:.,. _;;;rYc;,...,. issue t.3 r Application Kidde VS Series life safety systems are powerful intelligent solutions of strobes to UL 1971 standards. For Genesis devices,enabling for small to mid-sized buildings.Advanced intelligent technology this feature allows horns to be silenced while strobes on the same delivers the benefits of flexible system installation,while clean and two-wire circuit continue to flash until the panel is reset. easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide The smart choice an added measure of flexibility.Their slide-in labels take the mystery Electronic addressing eliminates the tedium of setting dipswitches, out of custom applications,and present a clean finished appearance. and automatic device mapping ensures that each device resides on the system at its correct location. Meanwhile,innovative pro- Perfect for retrofits gramming allows the designer to customize the system to pre- Kidde VS Series control panels are particularly well-suited to cisely suit the needs of the building owner. retrofit applications.All connections are made over standard wiring -no shielded cable required.This means that in most situations Reliability you can count on existing wiring can be used to upgrade a legacy control panel The inherent fault-tolerant characteristics of Analog/Address- to VS technology without the expense or disruption of rewiring able Technology boosts the reliability of Kidde fire alarm systems. the entire building.VS control panels also support the ingenious When combined with VS Series smoke and heat detectors,these RZI16-2 zone module,which adds up to 16 conventional circuits systems deliver a level of dependability not previously available and two NACs.This combination easily accommodates new intel- for small to mid-sized applications,All Kidde systems are built to ligent detection alongside existing conventional circuits, making it exacting reliability benchmarks and meet international standards an superior solution in the retrofit market. for quality,in addition to agency listings for dependability. Scalable IP and Cellular Communications Clear-cut remote annunciation Several popular third-party IP/Cellular communicators have been Remote annunciation is a strong suit of the VS Series fire alarm tested with the VS control panels and are compatibility listed to systems. Up to eight annunciators can be installed on a single UL864.The IP/Cellular communicators meet NFPA72 2013 edition system.Compatible annunciators include a range of LED and LCD requirements for sole or secondary transmission paths. Using IP/ models that provide zone or point annunciation, as well as com- Cellular communicators can reduce the cost of ownership by mon control capabilities.VS control panels also supports graphic eliminating POTS lines. Please see the VS control panel compat- annunciation with optional graphic annunciator interface modules. ibility documentation part number 3102354-EN for a full list of Each interface provides common control and 32 LEDs. compatible communicators. Signals with a difference A complete line of accessories VS Series NACs are configurable to fully support the advanced VS Series life safety systems are supported by a complete line of signaling technology of Kidde Genesis and Enhanced Integrity no- analog/addressable detectors, modules and related equipment. tification appliances.These devices offer precision synchronization Consult the Ordering Information section for details. Programming and remote diagnostics Dimensions Kidde VS Series life safety systems are simple to set up,yet offer 0) r21 tsl fat advanced programming features that put these small building02� T iO3 Dr panels into a class of their own.The auto programming feature 01 O o 6 o o quickly gets the panel operational using factory default settings. (` t ® O Basic zone and point settings can be programmed through the O 1 O jo front panel interface,so the system is up and running in no time. t t O oa C IC For more advanced system configuration and correlation groups 01 t O Da � programming,VS Series systems interface to a PC running com- © _o O to patible VS-CU software.This option offers full system configura- tion in the familiar Windows®operating environment.Connection is made to a laptop through the panel's optional RS-232 communi- cations port,which can also be used to connect a system printer. Among the many innovative features of VS Series control panels t` 'I is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet®network connection that permits access (2)Semi-Flush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols.The connection can be used to down- Panel dimensions,in(cm) load to the panel from the VS-CU,or upload and view system Model Dig I D2 ; D3 D4 D5' D6 D7 I D8 1 D9 reports using the VS-CU. vs4 28.0 3.85 9.0 22.0 15.75 10.25E4. 30.1 ; 2.7 (t1.1) (9.8) (22.8) (55.8) (40.0) L(26.0) p6.4) i (s.8) Available system reports include:Correlation groups, Device de- vs1 21.5 3.85 i 7.5 15.5 14.25 23.6 2.7 tails, Device maintenance, History, Internal status,System configu- (54.6) (9.8) 1 (19.0) (39.4) (36.2) (59.9) (6.8) ration, System status,Walk test, Dialer,and CO runtime. 'Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim idt.The trim kit y provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. 0 Page 2 of 8 DATA S f I F E r V85005-0135 � Not to Isaac; ;czr ir:.tail,'c;i<.si ;,;;;r a<>:_ issuel.3 � r System Layout VS4 Any combination of two single-or dual device loop modules _ --------------------------------- -------------------------------------- 1. I.h Standard Loop:250 points(one expansion slot) V-SLC2-2 Expander,Loop 1 of 2:250 points Up to 125 sensors and 125 modules per loop (one expansion slot) -tom.. Vr'w 1f SLt;?_1 Exp:a€der Loop:250 points(one expansion slot) V-SLC2-2 Expander,Loop 2 of 2:250 points Up-to 20,000 feet of-wiring-per loop- ----- i~z � �-'"r; �?x _,, ,• tom.-.-:- ---- - - ' Four Glass B or two optional Class A NACs Four Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster — ! Ethernet(SA-ETH) ]� _ _ ----}• —— . DACT/Dialer(SA-DACT) _ Up to eight remote annunciators RS-232(SA--, Yi.=��`t Sixteen Conventional IDCs, Relays:Two Form C,one Form A ` °4r.. ., ` two additional NACs with RZI16-2 module y'KFdde Each VS4 panel has room for up to two device loop controller modules in any combination of single or Panel Layout dual 250-device loops.VS4 comes with one loop that supports up to 125 detectors and 125 modules. a 3 O 018 80 5 VS1 5® � 8 1 9 ��U7��•^.ram.I f '�/•_ ``a' fi'._���' - — � 00:O B Loop supports up to 64 intelligent devices of any type. :.. — Y t0 Up to 20,000 feet of wiring. t ii is Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply ' � o i; 1 Transformer rr.; 2 Main AC wiring block&fuse holder to eight t�«ru,.nc;iatnrs 3 RS-232 card connector(J3) 0 Ethernet(SA-ETH) ,. 4 Dialer card connection(J8) 5 Ethernet card connector(J1) DACT/Dialer(SA DACT) 6 Main circuit board RS-232(SA-232) 7 Panel backbox enclosure Relays:Two Form C,one Form A 8 Operator interface 9 SLC card connector(J7) 10 Class A card connector(J2) I, Each VS1 panel ships with one device loop controller that sup- 11 Tie wrap mounts ports 64 devices of any type.This panel's device capacity cannot 12 LED expander connector(J6) 13 Standby batteries be expanded. Page 3 of 8 D N T A S H T V85005-0135 Mot io P)O tssc;d Yu: itt<,U[II:';ticat ;?til'r4Gr�:�- ISSUE 1.3 r Wiring & Configuration Device loop Auxiliary&smoke power outputs(TB3) The system provides one device loop circuit with a total capacity The control panel provides two auxiliary power T133 of 125 detectors and 125 module addresses.The loop circuit is outputs that can be used for powering ancillary supervised for opens,shorts,and grounds. equipment such as remote annunciators and two No (1) wire smoke detectors, Aux 2 can be software NC specifications Circuit VS4 VS1 selected tooperate continuously.The circuit is ' Device loops One Class B or A One e Class B or A loop, supervised for shorts and grounds. loop,supporting 125 ( supporting64 devices of - - (2) NO Circuit specifications detectors and 125 j any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to 1 range _ _ _ @ NC four loops. I Resettable circuit 24 VDC nominal at 500 mA (3) Communication Maximum 20 V peak-to-peak _ (Aux power 2) NO line voltage Continuous circuit 24 VDC nominal at 500 mA. Circuit current 0.5 A max (Aux power 1) Use this circuit for powering O Circuit 660 total,0.5 pF,max two-wire smoke detectors. impedance (4) Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that O Signal Supported on a system-wide basis(all device loops) amount. Synchronization when using an addressable notification appliance (1)Trouble circuit(NAC)module and Genesis or Enhanced Integrity notification appliances. (2)Supervisory Alarm,trouble,and supervisory relay(TB3) (3)Alarm Class Wr,.g ClassAwiring The trouble relay is normally-open, held closed, and opens on any trouble event or when the (4)Smoke/Aux SLC A Data Line SLC A panel is de-energized.The supervisory relay is normally-open,and closes on any supervisory SLC B , i SLC B ,m �MPdL.I.P. event.The alarm relay changes over on any Loop Loop Loop card dW- device Loop card oa�L,na alarm event. Relay specifications Alarm Trouble Supervisory_ ----- ----- ------— - Notification appliance circuits(TB2) Type Form C Form A VS4 control panels come equipped with four notification appliance Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive circuits.VS1 control panels come with two NACs. Each circuit can Relay circuits can only be connected to power-limited sources. be individually configured for continuous,temporal,synchronized, and coded output. Specifications VS4 VSi Annunciator loop(TB4) Circuit Type 4 Class B or 2 Class A I 2 Class B or 2 Class A The control panel provides a connection for up to eight serially with SA-CLA module driven and supervised remote annunciators. Voltage 24 VFWR Current 6.0 A total,2.5 A max. 1 3.75 A total,2.5 A max. Circuit specifications per circuit at 120/230 per circuit at 120/230 Device loops_ Class B(Style 10 or Class A(Style Z) VAC 60 Hz. VAC 60 Hz. Circuit voltage 2.55 V 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit current 30 mA max per circuit at 230 VAC per circuit at 230 VAC Circuit Up to 8 annunciators or 4000 feet _ 50 Hz. i 50 Hz. impedance Impedance 26 0 total,0.35 pF max - — EOLR 15 K 0,�/2 W Class B Class A Synchronization Supported system-wide Channel) Channel Channel Channel Closs B wiring Class A wiring TB4 T64 NAC,- + + NAC,- + + 0 NAC1� jo , Annunciator Annunciator NAC2- + + EOLR + + CH1(+)IN CH1(+)IN NAC2+ - - CH1(-)IN CH1(-)IN TB2 T02 NAC3- + B2 - t9 CH2(+)IN CH2(+)IN e NAp. - - EOLR e + (9 CH2(-)IN CH2(-)IN e NAC4- + + - TBO TB6 Marking indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown in active state. 0 N Page 4 of 8 (> 17 t-. l V85005-0135 riot to t;,, usc„ -:u in:.talte,(ior: . issue1.3 V � Option Cards KiddoYG Series panels are supported bya complete line ofmod- RZ|1G-2 Remote Zone Interface Module u|ea and related equipment that enhance performance and extend system capabilities.Option cards plug directly into the control panel main circuit board or are connected toit with a ribbon cable. After installation,terminals remain accessible.The cabinet pro- vides ample room for wire routing, keeping wiring neat at all times. - ---- Ging|eandDuolLoopConmnoUorCon]o The RZ|10'2 Addressable Remote Zone Interface Module ioan The V-GLO2'1ioa single loop controller card that can beused addressable device that provides connections for sixteen Class B with the V@1eoa replacement for the standard 64'Point loop. or Initiating Device Circuits and two Class B Supervised Output with the V84ana25O'point expansion module. Circuits,The inputs and outputs can be configured individually for The V-GLO2'2ioa500'point dual loop controller card for the VG4 several device types. that provides two|DC circuits,each with 12§detector addresses The RZ|18'2 requires 18 consecutive addresses on the Signaling and 125 module addresses. Line Circuit<SLq.Addresses are assigned electronically There are nn address switches toset. SpecificationsTheRZi1O'2incoqno��em�m8'negmontD|Pmwitchou#he1am Device Addresses device addresses i device addresses used toselect the AJannor Supervisory default device type for each of the 16 iDC;circuits.The module also includes one 4-seg- VS1:64 addresses I ment DIP switch used to select the default Relay or NAC output Wiring" device type. Da�ootypes other than the d�au8are accomplished —Operating Current Standby,55 mA---T— Standby:45 mA through programming, (fullyloaded � _ R��e'oopevnioouons. Note:7hese ratings do not include the use of two-wire smoke modules. Voltage Voltage Supervisory current: 25nmAeuz4voCnominal Terminal Rati Alarm current: 1000mA Circuit Current 24vXvuxminimum: 18.4vOC ����G�G�o 240Auxmaxmum: 2e.4vDC resistance wAC1.N*Conominal: 24voC Max total loop 0.5 pF Current capacitance Standby current Isolators ors maximum per loop(total both for 4.7uEOL(u.a) 48m*Jcircuit isolator bases and modules) Standby current for n.axsoL(Canuna) n.rm*/circuit Alarm current ' at nominalvnu 31.1 mA/oimuu Quantity 2 Type Rating(pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 Q per wire SA-Es* Ethernet Interface Card resistance SA-ET*vw,mo The 6A-ETH card provides a Initiating device circuits n`network u�mdunJ101O0B�eTBhe� Quantity1n w �n""�"" net network connection for EOLmvimor 4.rxo(U.G.);a.SxoCanada connecting Vomnintmne1 a|omd zo»*«o««8e ��J � J oY ,^ mz<U�G.) ' xconV for n�nku�anad� network,or the|ntomet.The Alarm current u1.1mx/channel�nominalvoltage card can be used todownload Alarm impedance range ^soou configuration programming from Trouble impedance range >nnoxo the VS'CUto the panel. Supervised output circuits � sOLmmotor 15mz The Ethernet card ia installed un Quantity o the plastic assembly and con- Short circuit detection <u.uwD ne�ato the main�rcu�board Open oimu�d�a��n >o1.ohu Ethernet card via a ribbon cable. Contact ratings 24 voc at oox ��sznpecm(��ns Compatible Ethernet 10/100 Base T --bp--e--rating environment V85005~01 35 SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 in- SA-232 wiring GNDck wire) panel and the central station over a telephone line system. It terface with VS panels. It can be used for TXD(while aewire) TXD(white wire) transmits system status changes(events)to a compatible digital connecting a printer to the control panel RXD(red wire) alarm communicator receiver over the public switched telephone to print system events.The card also network.The dialer is capable of single, dual, or split reporting can be used for connecting a computer ®� of events to two different account and telephone numbers.The to download a configuration program Pr modem feature of the SA-DACT can also be used for uploading from the VS-CU to the control panel. and downloading panel configuration, history, and current status to a PC running the VS-CU. The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon SA-DACT Phone line 2 cable. wiring To wall Phone line 1 phone Jack - SA-232 specifications Phone cables Operating voltage Standard EIA-232 (supplied) RJ31 jacks � _Terminal rating _ 12 to18 AWG(0.75 to 2.5 sq mm) The dialer phone lines connect to Operating environment connectors on the dialer's main Temperature 32 to 120°F(0 to 49°C) ® ® circuit board.Phone line 1 connects Humidity 0 to 93%RH,noncondensing at 90°F(32°C) to connector J4 and phone line 2 connects to connector J1. ?O XtEl:(moo SA-CLA Class A Module(VS1 only) o❑❑®e® 0 The SA-CLA card provides Class A capability for NAC wiring. o❑❑❑LJ a Its terminal block provides the wiring connection for NAC return ❑0Co$ Do wiring.The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card.The SA- The SA-DACT queues mes- CLA is compatible with VS1 control panels only.VS4 panels are sages and transmits them based on priority(alarm, supervisory, Class A Ready.The SA-CLA is installed directly to the control trouble, and monitor).Activations are transmitted before restora- panel circuit board using its plastic standoffs and plug connection. tions. SA-CLA specifications The SA-DACT is installed on the plastic assembly and connects to Operating voltage 24 VFWR _ the main circuit board via a ribbon cable. Operating current 3.75 A FWR total at 120/230 VAC 60 Hz SA-DACT specifications 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Phone line type One or two loop-start lines on a public, network _Circuit impedance 26 ohms,0.35uF switchedTerminal rating 12 to18 AWG(0.75 to 2.5 sq mm) Phone line connector RJ-31/ network 8� Operating environment Communication formats Contact ID(SIA DC-05) Temperature 32 to 120°F(0 to 49°C) Operating environment Humidity 0 to 93%RH,noncondensing at 90°F Temperature 32 to 120°F(0 to 49°C) (32°C) Humidity 0 to 93%RH,noncondensing at 90°F - (32°C) Compatible DACRs D16L-VS LED Display Expander(VS4 only) Receiver Models Formats The D16L-VS LED Display Expanders provide LED annuncia- Ademco 685 Contact ID tion for up to 16 zones. It provides two LEDs for each zone.Two FBII CP220 Contact ID D16L-VS LED display expanders can be installed in each VS4 Osborne-Hoffman OH 2O00 Contact ID panel. Bosch D6600 Contact ID Silent Knight 9800 Contact ID (3) (4) SG- LR , LR2� Contact ID (2)Sur Gard � 8oO nU �] 1� 81zo n R❑ o 7O � (1)LED 1 (sl (2)LED 2 (3)LED Expander 1 (4)LED Expander 2 (5)Alarm/non-alarm and trouble zone LEDs 0 Page 6 of 8 D A FA S H E C r V85005-0135 J Not to L"r, jac;o For Issue 1.3 x Specifications VS1 VS4 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop:124 Notification appliance 2 Class B(Style Y),Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz,1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA,24 VDC circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) Output:28.3 to 21.9 VDC,special application Note:For a list of compatible devices,see the VS1 and VS4 Series Compatibility List(P/N 3102354-EN) Loop circuit Maximum loop resistance:66 D Maximum loop capacitance:0.5 pF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm: 125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid _ Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet.If larger batteries are required,use a battery cabinet. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(C31/38)) Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.:100 mA FCC registration number:GESAL01 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1 B Ground fault impedance 0 to 5 kQ Alarm contact Form C N.O.24 VDC at 1 A(resistive load) Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) Environmental Temperature:0 to 49°C(32 to 120T)Relative humidity:0 to 93%noncondensing Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) Page 7 of 8 0 A T A. s H t_t_ T V85005-0135 Not lo I_-a,:.*:. ,.;r r.;, ;la::,tii,; .EtrF<,s ., Issue 1.3 Ordering Information - - _ ��® Kid e Part _ Des cri- VS4 Fire Alarm Syption stems VS4-G Four loop system with one 250-point loop installed.110v,gray door. Technology that saves lives VS4-G-2 Four loop system with one 250-point loop installed.230v,gray door. VS4-G-2-PG Four loop system with one 250-point loop installed.230v,gray door,Portuguese. Contact us... VS4-G-2-SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. _ Email:kidde.fire@fs.utc.com VS4-GC Four loop system,one 250-point loop installed. 110v,gray door,LED strips,Canada. Web: Kidde.com/EngineeredSystems VS4-GD. Four loop system,one 250-point loop installed. 110v,gray door,with dialer. _ VS4-GF Four loop system,one 250-point loop. 110v,_gray door,LED strips,French Canada. VS4-G-PG Four loop system with one 250-point loop installed. 110v,gray door,Portuguese. Kidde is a UTC brand. VS4-G-SP Four loop system with one 250-point loop installed.110v,gray door,Spanish. 1016 Corporate Park Drive VS4-R Four loop system with one 250-point loop installed.110v,red door. Mebane,NC 27302 VS4-R-2 Four loop system with one 250-point loop installed.230v,red door. ©2017 United Technologies Corporation. VS4-RD Four loop system,one 250-point loop installed. 110v,red door,with dialer. All rights reserved. SA-TRIM2 VS4 Flush mount trim,black. VS1 Fire Alarm Systems VS1-G One loop system with one 64-point loop installed.110v,gray door. VS1-G-2 One loop system with one 64-point loop installed.230v,gray door. VS1-G-2-PG One loop system with one 64-point loop installed.230v,gray door,Portuguese. VS1-G-2-SP One loop system with one 64-point loop installed.230v,gray door,Spanish. VS1-GD One loop system,one 64-point loop installed. 110v,dray door,with dialer. VS1-GL_ One loop system,one 64_point loop installed. 110v,gray door,English Canada. VS1-GL-F One loop system,one 64-point loop installed. 110v,grr door,French Canada. VS1-G-PG One loop system with one 64-point loop installed.110v,gray door,Portuguese. VS1-G-SP One loop system with one 64-point loop installed. 110v,gray door,Spanish. VS1-R One loop system with one 64--point loop installed.110v,red door. VS1-R-2 One loop system with one 64-point loop installed.230v,red door. VS1-RD One loop system,one 64-point loop installed. 110v,red door,with dialer. SA-TRIM1 VS1 Rush mount trim,black Option Cards V-SLC2-1 Expansion module,one 250-device loop.For VS4 only. V-SLC2-2 Expansion module,two 250-device loops,500 devices total.For VS4 only. RZ116-2 Remote Zone Interface Module.16 Class B IDCs,2 Class B Output.Bracket included. SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers&computers,mounts in cabinet. SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. SA-CLA Class A adapter module.Provides Class A capacity on NACs.Mounts in cabinet on main board.VS1 systems only. D16L-VS LED Annunciator module, 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display.For VS4 only, D8RY-VS Canada only.LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory.Mounts in cabinet.For VS4 only. _ Accessories CTM City Tie Module.2-gang.Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet,8"x 14"x 3.5"-red. BC-1 Battery Cabinet.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1 R Battery Cabinet-Red.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. GSA-REL Releasing Module BC-1 EQ Seismic hardening Kit for VS Series panels.Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools _ VS-CU VS Series configuration and diagnostics utility, 260097 RS232 cable,4 conductor,DB9 PC interface 0 Page 8 of 8 D A f A S H F.E 1- V85005-0135 Not to E;v? lt.v., for m",+faHi ,iir>4'i 1!'i::ca>..._ Issuel.3 V . a v Annunciation r J A,: Technology that saves lives „ p0 r ar R";e m 0 t retk e, o11 lul Iciatu'-' r."15 iiio Ef RLCD RLCD-C RLED, BLED-C, ' RLED24, CCI _ flr y' i'� Wde j FDNY 7120-1657: UDC COA 6020 0254 S3424 Overview Features Kidde R-Series Annunciators are high-performance remote an- • LCD models feature large 4 x 20 character backlit LCD display nunciators that provide status indication and common controls for . LED models provide 16 pairs of LEDs for zone annunciation compatible fire alarm control panels.This family of annunciators offers LCD or LED annunciation. Models are available with and • Available expander extends capability with 24 pairs of LEDs without common controls. • Up to two expanders may be wired to each annunciator There are three R-Series annunciator models,plus an LED-based . Status LEDs and internal buzzer standard on all models expander.Up to two expanders can be connected to any annun- ciator.The expander includes 24 pairs of LEDs that extend the Common controls available for LED and LCD display models capabilities of any of the annunciators. • Available keyswitch for disabling common controls All annunciator models include status LEDs and an internal buzzer. . Standard 4-inch square electrical box mounting Two models have an LCD text display,and one has 16 pairs of Class B or Class A RS485 wiring standard LEDs for zone annunciation.LCD models feature a large back-lit, four by twenty character per line,super-twist liquid crystal display. • One-,two-,and three-position enclosures available R-Series annunciators and expanders are mounted on a standard • Graphic Annunciator interface,includes common control,indi- 4-inch square electrical box, using the included mounting ring. cators and 32 LEDS They can also be surface mounted in locking steel enclosures. . No programing required, set the address and unit receives all Three different enclosures are available. information from panel A keyswitch and graphic annunciator interface is available for R-Series annunciator applications.The keyswitch enables or dis- ables common controls.The graphic annunciator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Papa,of D^:TA ,H K85005-0128 No4 "o .i. .-.>.,, lot,,>i:•.T':.i{,".t:Qt:S,'13i ELT;•...... Issue f Application Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A data riser.This can be configured for Class A or Class B commu- nication.Annunciators do not provide ground fault isolation. FACP Annunciator Annunciator RS485 CHI IN CHI IN These annunciators are stand-alone units that can be powered by CHI+ ' CH1(-)IN CH,(-)IN the FACP or by an approved power supply. CH - DH,(+)GDT 0 CHI(+)OUT CH2+ 0 CH1(-)OUT CH2- CH2(+)IN CH2(+j IN CH2(-)IN CH2(-)IN _ °a °o LISTED 24 VDC CH2(+)OUT 0 CH2(+j OUT ° � 00 0 SUPPLY CH2 I-)OUT 0CH2 OUT d � d 24 VDC+ 24V(+)IN 24V(+)IN e0 a� a 24 VDC- 24V(-)IN 24V(-)IN 00 n w o O a w 24V(+)OUT 0 24V(+)OUT 24V(-)OUT 0 24V(-)OUT � E GROUND GROUND RLCD-C RLED-C Annunciator, Class B 0._ ° ° FACP Annunciator Annunciator d°""10ve °00 o RS485 CHI(+)IN CHI ®®® °off°o IN °00°o CH7+ CH7(-)IN CHI(-j IN 000°o CH,_ CHI(+)OUT 0 CHI(+)OUT °oO°o CHI(-)OUT 0 CHI(-)OUT D 0 CH2(♦)IN 0 CH2(+)IN 0 CH2(-)IN 0 CH2(-)IN RLCD RLED24 LISTED 24 VDC 0 CH2(+)OUT 0 CH2(+)OUT Features by model RLCD RLCD-C RLED-C RLED24 SUPPLY 0 CH2(-)OUT 0 CH2(-)OUT Reset ✓ ✓ ✓ 24 VDC+ z4v(+)IN 24V(+)IN _. 24 VOC- 24V(-j IN 24V(-)IN Ack/Silence ✓ ✓ ✓ — 24V(+)OUT 0 24V(+j OUT Fire Alarm ✓ ✓ ✓ 24V(-)OUT 0 24v(-)our Supervisory ✓ ✓ ✓ GROUND GROUND Ground Fault ✓ ✓ ✓ —_ Trouble ✓ ✓ ✓ Controls Enabled ✓ ✓ ✓ Ack/Silence ✓ ✓ ✓ -- Expander Reset ✓ ✓ - - -Ex Ann unclator First Expander Secontl Expantler Signal Silence ✓ ✓ Drill ✓ ✓ OUT IN OUT IN OUT Lamp Test ✓ ✓ ✓ v(+) v(+) v(+)0 - -------j Ov(+) v(+)0 LCD Display ✓ ✓ F F F 0- - -------:- O F Fe Zone Active LEDs 16. 24" E E E 0- - -------;- E E 0 Zone Trouble LEDs - - 16 24 D D DO- - -------;- 0 D Do ------ --- -- c c c 0- --------- 0 c CO .zones 13-16 maybe selected as Supervisory on FX-64 and VS7 ., B B B 0- --------- B SO , zones 13-16 and 29-32 may be selected as Supervisory on FX-1000 and VS4 ; .._ A A A A 0 , ---------------------- Graphic Annunciator Interface The GCI Graphic Annunciator Driver is an interface card that connects the fire alarm control panel to the display panel of an Remote Keyswitch LED-based graphic annunciator. Annunciator LSRA-RK The annunciator card supports 32 LEDs and 16 switches on the KEYSWITCH(-j graphic panel display. It includes status LEDs and an internal KEYSWITCH buzzer. The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc voltage The annunciator communicates with the FACP on the RS-485 -Maximum 200 mA data riser.This can be configured for Class A or Class B commu- current nication.The annunciator does not provide ground fault isolation. Mounting 2-1/2 in(64 mm) It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box approved power supply. Termination _Screw terminals Maximum 12 AWG Graphic Annunciator Interface Specifications - wire size (2.5 mm sq) Alarm current _ _ 146 n-A at 24 Vdc(with 36 LEDs ON) Contact Normally open Standby current 36 mA at 24 Vdc(with no LEDs ON) configuration Maximum current 10 mA per LED Page 2 of 4 U A 7 A 5 F I E EK35005-0128 TSrt to i)c ua[^ci ICr issue 1 Annunciator Connections Annunciator Mounting Annunciator ANNUNCIATOR RS-485 RISER Mounting slot IV DIP switch a® O RS-485 riser Remote keyswitch terminals u n terminals Power terminals �,,,. Expander cable °terminals communication o O LEDs o ® O 0 Expander O Mounting slot EXPANDER CABLE I': o c.�� Expander cable Jf i Expander cable terminals terminals •. ® O ® 0 0 DIP switch settings O Switch Description and values ° S1 to S5 The annunciator network address(in binary). O Network The factory setting is for address 2. address Examples:10000=1 01000=2 11000=3 00100=4 S6 Network OFF=9600 baud(factory default setting) _baud rate ON=38,400 baud_ S7 to S8 Not used MOUNTING RING EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure,surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover, and key lock. The enclosures are 16-gauge welded steel with a white,painted 6.0 in finish. Each enclosure includes a security lock and two keys.The 15.2 cm two-and three-position enclosures have wiring channels for cor- H rect routing of interconnections. The enclosures attach to a standard electrical box,and provide a �j mounting lip that takes the place of the integral mounting ring sup- Uuu plied with the annunciators and expanders. 0.9 in 2.3 crr v \• c 5 i BBBBB PA-ENC1 9.5 in I 24.1 cm 2.0 in O G 9.8 in 5.1 cm 24.9 cm Dimensions(H x W x D) BBBBB RA-ENC1 6.3 x 9.8 x 2.0 in(16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in(30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in(45.0 x 24.9 x 5.1 cm) RA-ENC3 Note:Allow approximately 2 inches(50 cm)clearance on both sides of the enclosure,to permit inserting and removing the key,and opening the door RA-ENC2 through 90 degrees. Page 3 of 4 DATA S I I E E r K85005-0128 Not to ;'3u uc^..@ €e;insiaar's°.:cxi purpoE•eb. Issue 1 -� Specifications ,41 RLKiddeCD-C RLCD BLED-C _ RLED24 Operating voltage 24 VDC,continuous. Standby current 99 mA 98 mA 28 mA 6 mA Technology that saves lives Alarm current 115 mA 113 mA 62 mA 34 mA Contact us... RS-485 communications Class A or Class B,9600 baud Email:kidde.fre@fs.utc.com Data wiring 18 to 14 AWG(1.0 to 2.5 sq mm)twisted pair(6 twists per foot Web: Kidde.comlEnoineeredSystems minimum).Maximum wire run is 4,000 ft.(1,219 m) Remote key switch circuit 5 VDC at 1 mA,power-limited,unsupervised Kidde is a UTC brand. Ground fault impedance 0 1016 Corporate Park Drive Power wiring 18 to 14 AWG(1.0 to 2.5 sq.mm) Mebane,NC 27302 _ Display area 4 lines of 20 characters each ©2016 United Technologies Corporation. Dimensions(H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in.(14.3 x 21.4 x 3.8 cm) All rights reserved. Mounting North American 4-inch square electrical box or listed enclosure Agency Listing UL,ULC _ V. Operating environment Temperature:32 to 120°F(0 to 49°C)Humidity:0 to 93%RH, noncondensing at 90°F(32°C) Ordering Information Part Description Remote Annunciators _ K-RLCD LCD text annunciator without common controls. English. K-RLCD-R LCD text annunciator without common controls.English.Red. K-RLCDF LCD text annunciator without common controls.French. K-RLCD-C LCD text annunciator with common controls.English. K-RLCD-CR LCD text annunciator with common controls.English.Red. K-RLCD-CF LCD text annunciator with common controls.French. K-RLED-C 16-pair LED zone annunciator with common controls.English. K-RLED-CR 16-pair LED zone annunciator with common controls.English.Red. K-RLED-CF 16-pair LED zone annunciator with common controls.French. Remote Expanders K-RLED24 24-pair LED zone expander with expander cable and zone card insert. K-RLED24R 24-pair LED zone expander with expander cable and zone card insert.Red. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-MIR-SB Surface Mount Box-for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/supv zones as well as inputs for common switches.Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling common controls(Lock/Unlock). 27193-16 Electrical box,surface mount,white,single-gang,for RKEY. 0 Page 4 of 4 DATA SHEET K85005-0128 rn Pi;l to i;o cinor.t for ntY,tail;ltirlst (7ur:?oses. issue p power Supp11es and Access"!" ..... ..... * d tha t saves Tech�Oi°gy L ' u3c S3424 PoWer psjo/� M11." it p6P S6 A, t''t 7300-1493: �\(} 0174 fM Lures regulated power to be installed Standard Fea Allows for reliable filtered and list ansion U�864 9ih Edition where needed ex notification aP_ stem integrity pVervlew I gRBP ) and suP Cast effective system Enhanced S is a ervised Booster Power SuP24 Vdc filtered-regulated, for Genesis and The B It is a rovide additional notfcation Provides ed power supply'• ured top ass Notification/ pliance synchronization operation config ower for M security, coded output op ACs)or auxiliary P We as life safety, Supports co protection unit that c circutsYW MNEC),as overcurrent P appliance Communication l Self-restoring Emergency applications charge internal 1e signal rates eodentiy control apP to monitor and two Multiple controlled indep and access room for up to ' cascaded Or contains the circuitry Can be iRSPS lications, oration or internal faults The M Its steel enclosures ntroi-only apP ere-hours Easy field config s identify wiring ovable For access to 65 amp convert- nostic LED, or external hournbatteries• atteries totaling four Class t On_board diag h 1 0 ampere- can supP°rt b MIRBPS has led in one or two rd Kidde keyed lockable steel cabinet With the MIRBPS be activa standard in an external ass N NACs These can Input circuits• door vailable Class A) i ue dual inp vac models a ibie to two the MtRBPS's un q ere models.Each output .1.t0 and 230 WG wire sizes s from 10 amp cannot 1 g to 12 A group 6.5 or total current draw Accommodates S is availaboi f three amperes; tamper switch -approval The t has capacity Optional In rates re is listed under char9 9 p seismic p circuit has a rating battery P unit's uirements and � puai b h uake hardenin9�OSH exceed the current U�req Factor 1.5 IRBPS meets � Optional on a Importance The M standards' for comp the followln9 pescription CGN} S stems s - Standard( itlon(UOXx}Fire Ala nits and System stems 9th ed. --HoiduP Naar nits and SY U18�t1ENX7} arm _..- ~� stems U16361E1' AO IX71 Local Bu�oi SYstertms__`lar Alarm Units and system! 01 AA UE X7}--p ce$St lion Cne B�Ste rn units CTL2 '"PAw7} u rg ar Alarm SY UL365(APAW_A-.----pU7} Pr� Ata, Unt -APOU.AI' tation re aTm(C�adaster�nada) U�1— ( r'Central S UL161 OXXG Control units,Alarm Units ans UJlC.g527(�}—�ooa1 Bur E4u+pment(Cada� q r� UlC S303 205 Signaling 05 G22.2 No.— �[ _ .� 850 Issue t 1i�ir��`i':�;>tit>n'i�tiftYr{z':,i: page 1 014 9 Application Dimensions The MIRBPS provides additional power and circuits for notification appliances and other 24 Vdc loads. It is listed for indoor dry loca- tions and can easily be installed where needed. O Top View O Fault conditions are indicated on the on-board diagnostic LEDs, opening the MIRBPS input sense circuit and the trouble relay(if If-D2 D3 programmed).While this provides indication to the host system, the MIRBPS can still be activated upon command.A separate AC Of—D4�0 Fail contact is available on the MIRBPS circuit board,which can be programmed for trouble or AC Fail.There are seven on-board o diagnostic LEDs:one for each NAC fault, one for battery fault,one a: Front View 0 for ground fault,and one for AC power. m The unique dual-input activation circuits of the MIRBPS can be activated by any voltage from 6 to 45 VDC(filtered-regulated)or to 0 11 to 33 Vdc(full-wave rectified, unfiltered).The first input circuit D1 D6 can be configured to activate 1-4 of the four possible outputs.The 0 second input circuit can be configured to control circuits 3 and 4. All knockouts m When outputs are configured for auxiliary operation,these circuits for 3/4 in conduit < can be configured to stay on or automatically deactivate 30 sec- . (1.9 cm) CD onds after AC power is lost.This feature makes these circuits ideal for door holder applications.The MIRBPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. MIRBPS NACs can be configured for a 3-3-3 temporal or continu- D1 D2 D3 D4 D5 D6 ous output.California temporal rate outputs are also available on 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in certain models.This makes the MIRBPS ideal for applications re- (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) quiring signaling rates that are not available from the main system. In addition to the internally generated signal rates,the MIRBPS can also be configured to follow the coded signal rate of the main Wire routing Power-limited system NACs.This allows for the seamless expansion of existing wiring area NACs. The MIRBPS enclosure has mounting brackets for up to three . Signature modules to the right of the circuit board. np o° Engineering Specification Supply,where needed, Kidde MIRBPS Series Booster Power Sup-plies(MIRBPS)that are interconnected to and supervised by themain system.The MIRBPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. g ]r'F2'� The MIRBPS battery compliment shall be sized to match the RouteACsupply requirements of the main system.The MIRBPS shall be capable through these of supervising and charging batteries having the capacity of 24 knockouts only _ ampere-hours for Mass Notification/Emergency Communication (Nonpower-limited (MNEC), life safety and security applications,and the capacity of and supervised) Battery wiring (nonpower- 65 ampere-hours for access control applications. o limited and supervised) o <<The MIRBPS shall be capable of installation for a seismic com- Battery Battery ponent Importance Factor of 1.5.>>The MIRBPS shall provide a minimum of four independent,fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. MIRBPS NACs shall be convertible to a minimum of two Class A NACs. Each MIRBPS output circuit Notes shall be rated at 3 amperes at 24 Vdc. Each output circuit shall 1• Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited be provided with automatically restoring overcurrent protection. wiring or use type FPL,FPLR,or FPLP cable per NEC. The MIRBPS shall be operable from the main system NAC and/or [2] Power-limited and supervised when not configured as auxiliary power.Non- The Y supervised when configured as auxiliary power. Kidde Signature Series control modules. MIRBPS NACs shall be [3] Source must be power-limited.Source determines supervision. configurable for continuous,3-3-3 temporal or optionally, Califor- 4. When using larger batteries,make sure to position the battery terminals towards nia rate. Fault conditions on the MIRBPS shall not impede opera- the door. tion of main system NAC.The MIRBPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 of 4 n A.i.A s H E E T K85005-0125 IY r,t to bu uopci tpr msi.a'i,ttinn Issue f Typical Wiring Single or cascaded booster NAC Circuit To next signaling g NAC Circuit device,booster,or anywhere on a notification appliance circuit V Y— EOL resistor (D CID NAC output#1 Existing NAC end-of-line resistors are not required to be Fire Alarm C. N NAC output#2 installed at the booster's terminals.This allows multiple Control Panel CIDCID N NAC output#3 boosters to be driven from a single NAC circuit without the 5 s NAC output#4 need for special configurations. Booster Power Supply Configuring the Booster for Multiple CC1(S) modules using the AC Power Fail delay operation* MIRBPS's sense inputs TB1 Notification appliance circuit(NAC) TB1 Notification appliance circuit(NAC) NAC 1/+ UL listed NAC1/ + UL listed AUX1 - g Q a Q EOL 15 kQ AUX1 - a Q a a EOL 15 KW NAC2/+ Notification appliance circuit(NAC) NAC2/ + Notification appliance circuit NAC AUX2 - AUX2 - pp (NAC) NAC3/+ UL listed NAC3/ + UL listed AUX3 - II Y EOL 15 kf1 AUX3 -f=DuD EOL 15 KW NAC4/+ NAC4/ + AUX4 - AUX4 - 200 mAAUX + 200 mAAUX Continuous m - Continuous m IN + IN + Sense 1 COM FW - Sense 1 COM FW - OUT - + OUT EOL 47 K IN Eff IN + Sense 2 COM Eff EOL 47 kfl 109 Sense 2 COM Eff - OUT CC1(S)module[1][3] OUT EOL 47 K NO o o NO Trouble COM 87 65 4 3 2 1 Trouble COM o 0 NC NCR 109 109 Tg2 +- + +- Tg2 CC1(S)module CC1(S)module o a� e CT1 Data in from Data out to o 7 6 5 0 4 3 2 1 87 65 4 3 2 1 module[4] previous device next device 0 0 or Signature controller Data in from previous + + 'The Booster supports AC Power fail delay [3] device or Signature Data out to of three hours via its trouble contact when controller next device dip switch SW2-6 is on.All other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS TB1 24 V 12 V NACl/+ Security Security EOL AUX1 - 24DC12 device device monitoring NAC2/+ device AUX2 - NAC3/+ AUX3 - NAC4/+ AUX4 - Control panel BPS[1] Card reader Card reader [Card reader controller controller ontroller + + To next device [1] Disable the MIRBPS's ground fault jumper(JP3) or end Page 3 of 4 n r,1-A s I3 e:7--r K85005-0125 No). it,, bo klsferi for Issue s i Specifications a9 f �'� Model _ 6.5 amp Booster _ 10 amp Booster AC Line Voltage 120VAC or 220-240VAC 50/6OHz 120VAC or 220-240VAC 50/6OHz 390 watts 580 watts Technology that saves lives Notification Appliance 3.OA max.per circuit @ 24Vdc 3.OA max.per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 1 OA max total all NACs Contact us... Trouble Relay 2 Amps @ 30Vdc Email:kidde.fire@fs,utc.com Auxiliary Outputs Four configurable outputs replace NACs 1,2,3 or 4. as auxiliary Web: Kidde.com/EnoineeredSystems outputs and 200 mA dedicated auxiliary.(See note 2.) Input Current 3mA @ 12Vdc,6mA @ 24Vdc (from an existing NAC) _ Kidde is a UTC brand. 1016 Corporate Park Drive Booster Internal 70mA+35 mA for each circuit set to AUX Mebane,NC 27302 Supervisory Current Booster Internal Alarm ' 270mA ©2016 United Technologies Corporation. Current All rights reserved. Signature Mounting Space Accomodates three two-gang modules. 10 Amp Hours(2 of 12V1 OA)in cabinet up to 24 Amp hours with ex- Maximum Battery Size ternal battery cabinet for fire and security applications;up to 65 Amp hours for access control applications in external battery box. _ Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93%non condensing @ 32°C Temperature Rating 32'to 120°F(0'to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous,California rate,3-3-3 temporal, or follow installed panel's NAC.(See note 1.) Ground Fault Detection _ Enable or Disable via jumper_ _ Agency Listings v UL,ULC,CSFM 1. Model MIRBPS'CAA provides selection for California rate,in place of temporal. 2. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Number Description Shipping Wt. lb(kg) MIRBPS6A 6.5 Amp Booster Power Supply 13(5.9) MIRBPS6AC 6.5 Amp Booster Power Supply(ULC) 13(5.9) MIRBP_S6A/230 6.5 Amp Booster Power Supply(220V) _ 13(5.9) MIRBPS6CAA 6.5 Amp Booster Power Supply with California rate 13(5.9) MIRBPSI OA 10 Amp Booster Power Supply 13(5.9) _ MIRBPSI0AC 10 Amp Booster Power Supply(ULC) 13(5.9) MIRBPSI0A/230 10 Amp Booster Power Supply(220V) 13(5.9) MIRBPSI0CAA 10 Amp Booster Power Supply with California rate 13(5.9) Related Equipment 12V6A5 7.2 Amp Hour Battery,two required 3.4(1.6) 12V1 OA 10 Amp Hour Battery,two required 9.5(4.3) 3-TAMP Tamper switch Notes: BC-1 Battery Cabinet(up to 2-40 Amp Hour Batteries) 58(26.4) 1. Requires installation of separate battery BC-2 Battery Cabinet(up to 2-17 Amp Hour Batteries) 19(8.6) cabinet. BC-1 EQ Seismic hardening Kit for BC-1 cabinets.Includes battery hard- 2. MIRBPS supports batteries greater than ening order BC-1 enclosure separately._ 24 Amp hours for access control applica- tions BPSEQ Seismic kit for MIRBPS6A or MIRBPSI O Booster Power Su only. p- 3. For earthquake anchorage,including plies.See note 3. detailed mounting weights and center of 12V17A 18 Amp Hour Battery,two required(see note 1) 13(5.9) gravity detail,please refer to Seismic Ap- 12V24A 24 Amp Hour Battery,two required(see note 1) 20(9.07) plication Guide 3101 g87-EN.Approval of 12V40A 40 Amp Hour Battery,two required(see notes 1,2) 32(14.5) panel anchorage to site structure may re- 12V50A 50 Am Hour Batte two required see notes 1,2 40 quire local AHJ,structural,or civil engineer P ry, q ( ) (18.14) review. 12V65A 65 Amp Hour Battery,two required(see notes 1,2) 49(22.2) 4 Page 4 of 4 D A 1 A SHEET K85005-0125 €poi t+; bo usr.ti for in,taa;t?L,n {;ur>os„,. Issue 1 .^ ® Intelligent Initiating Ka r i dc' 01 le ELECT_RONI C �Iy��q A D D,-WESVS'I�N Technology that saves lives Manual 'Full r Stations LIFT THE:N7 PULL HANDL;` GSA—M270, GSA—M270P, `� , .. . GSA—M278 s. GSA-M270 SERIES GrKidde UL GSA M278V � UDC 7150-1483: 0139 M EA S2318 Overview • Break glass operation The GSA-M270 and GSA-M278 series Manual Pull Stations are An up-front visible glass rod on the GSA-M270 discourages tampering. part of Kidde's Signature Series system.The GSA-M270 Fire Alarm Manual Pull Stations feature our very familiar teardrop • Intelligent device with integral microprocessor shape.They are made from die-cast zinc and finished with red All decisions are made at the station allowing lower com- epoxy powder-coat paint complemented by aluminum colored munication speed while substantially improving control panel stripes and markings. With positive pull-lever operation,one pull response time. Less sensitive to line noise and loop wiring on the station handle breaks the glass rod and turns in a posi- properties;twisted or shielded wire is not required. tive alarm,ensuring protection plus fool-proof operation. Presignal . ADA Compliant models(GSA-M270P)are equipped with a general alarm(GA) Meets ADA requirements for manual pull stations. keyswitch for applications where two stage operation is required, The up-front highly visible glass rod discourages tampering, but is • Electronic Addressing with Non-volatile memory not required for proper operation. Permanently stores programmable address,serial number, type of device, and job number.Automatically updates historic Kidde's double action single stage GSA-M278 station is a contem- information including hours of operation, last maintenance porary style manual station made from durable red colored lexan. date, number of alarms and troubles, and time and date of last To initiate an alarm,first lift the upper door marked"LIFT THEN alarm. PULL HANDLE",then pull the alarm handle. • Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note.Some features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Stand-alone operation • Traditional familiar appearance The station inputs an alarm even if the loop controller's polling GSA-M270 models feature our familiar teardrop design with interrogation stops. simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs • One stage(GA),two stage(pre-signal),and double action Status LEDs;flashing GREEN shows normal polling;flashing models RED shows alarm state. GSA-M270 models are available for one or two stage alarm • Designed for high ambient temperature operation systems.The single stage double action GSA-M278 features a Install in ambient temperatures up to 120°F(49°C). rugged Lexan housing with keyed reset mechanism. Page 1 of 4 DATA SHEET K8500 1-02/9 Nui it; bt. Issue 1 � AnC}|'catOD T/n'no| Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18AWG(0.75mm) mined by their sub-type code cx"Personality Code".NORMALLY- 1o#12AWG(2.5mmg wire sizes.See Signature Loop Controller OPEN ALARM'LATCHING(Pamnmdhy Code 1)ia assigned bythe catalog sheet for detailed wiring requirement opeoifivationo factory;no user configuration is required.The device iaconfigured for Class B|DC operation.AnALARM signal ia sent tn the loop Wiring Notes controller when the station's pull lever ia operated.The alarm con- /k Refer to Signature Loop Controller manual for maximum ditionia latched ut the station. ^—^ wire distance. 2. All wiring ia power limited and supervised. Compatibilityxu^xv/aw Compatibility of 278 Signature Series manual stations are compatible only with Kidde's Signature Loop Controller. WarO'DQS & Cautions This device will not operate without electrical power.Aa fires fre+ Green LED que�|y cause pmwe in�rm[t|on.w*eugg��you d�ounofu�kor ~~~~ safeguards with your local fire protection specialist. lesf'DO & Maintenance To test(or reset)the station simply open the station and operate /DATA IN(10 DAmmnw\ the exposed awdoA.The GSA-�W27Omshea�e opened w�hmtool; \ DATA OUT the GSA'K4278 requires the key which is supplied with that station. From Signature c=*m. | m Next Device =Previous Device Z� The station's automatic self-diagnosis identifies when itiu defec- tive ondoaunoua\muNemeanage,Thouoer-friendlymaintemanoo Fk0una4, Single Stage Systems program shows the current state ofeach Signature series device and other pertinent messages,Single devices may bodeactivated temporarily,from the control panel.Availability ofmaintenance ��ueaio dependent on the 8malarm system used. REAROf �� ' Scheduled maintenance(Regular or Selected)for proper system 270P,270PB FT� cm cm operation should bo planned to meet the requirements ofthe Authority Having Jurisdiction y\H4. Refer to current NFRA72and ULCCAN/ULO538standards. Red LED Green LED lei /DATA=w ~~O~°� i �__-��*mno/ Fromsign mmrofl° | uwwn=*ce or Previous Devi.. 11 Figure 5. Two Stage Systems K85001-0279 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 1'/2 inch(38 mm)deep 4-inch square boxes with 1-gang, t/2-inch raised covers.Openings must be angular.Rounded openings are not acceptable. Recommended box:Steel City Model 52-C-13; in Canada,use Iberville Model CI- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Kidde recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station,saving valuable time during system com- missioning.Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box Compatible Electrical Box Cover Release Cover Release ' Screw a o o Back Q Plate o O Back Plate 0 Toggle Toggle NO AL° Switch o Switch o O cp NpRW ° Glass Rod ® Glass Rod }} Release Lever OPEN �5 I) o Figure 1. GSA-M278 installation Figure 2. GSA-M270 installation Cover Release Scr w Compatible Electrical Electrical Box m with cinch ,I raised covers ,r 1 a o . �. Back Plate I ' I,w u i Toggle o Switch NORMAL 0 0 Glass Rod ;trlj Release Lever Do not use CJ{. boxes with rounded openings. Figure 3. GSA-M270P installation Page 3 of 4 n A T As Fi E_, K85001-0279 t,�oi ir; bi, lrscri f,:,ii:S�a:l:;tion Issue 1 s - _ Specifications c i 66 'dde Catalog Number { GSA-M270 GSA-M270P, _ GSA-M278 Description Single Action Single Action Two Double Action One Stage Stage(Presignal) -One Stage Technology that saves lives Addressing I Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Contact us... i Standby=25OpA Standby=396µ4 Standby=250pA Operating Current I Email:kidde.fire@fs.utc.com __ I Activated=400pA Activated=68OpA Activated=400pA Web: Kidde.com/EngineeredSystems Construction&Finish Diecast Zinc-Red Epoxy Lexan-Red with with aluminum markings _ white markings Kidde is a UTC brand. Type Code j Factory Set 1016 Corporate Park Drive Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Mebane,NC 27302 -- - Operating Temperature:32°F to 120°F(0°C to 49°C) Storage and Operating©2016 United Technologies Corporation. Environment Storage Temperature:-40F to 140OF(-20°C to 60°C)Humidity:0 to 93% I All rights reserved. RH On-board Green LED-Flashes when polled _ a LED Operation On-board Red LED-Flashes w hen in alarm Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM,FM Ordering Information Ship Catalog Wt.Ibs Number Description _ (kg) GSA-M270 One Stage Fire Alarm Station, English Markings -UL/ULC Listed GSA-M270P Two Stage(Presignal)Fire Alarm Station,English Markings 1 (0.5) -UL/UL_C Listed _ GSA-M278 Double Action(One Stage)Fire Alarm Station,English Markings -UVULC Listed Accessories 270-GLR 20 Glass Rods-for GSA-M270 series (USA ONLY) 276-GLR 20 Glass Rods-for GSA-M278 series 8 Page 4 of 4 U r.I-A SHEET K85001-0279 V C. Nol io bu us(ocl l r ne.=aaa:ion 17ti,:csea. Issue Intelligent Initiating Devices 1*dde orle _ELECT_R-ONf i - +,1 ,-A D D R'E-S`S_I h G Jk Technology that saves lives Itell � Simi 10ke% Detu'-%ctorftzww _ , KI-PD t'00 UDC S853 0 Overview Standard Features The KI-PD optical smoke detector brings advanced sensing Note:Some features described here may not be supported by technology to a practical design that increases efficiency,saves all control systems. Check your control panel's Installation and installation time,cuts costs,and extends life safety and property Operation Guide for details. protection capabilities. Continuous self-diagnostics ensure reli Next generation optical smoke sensing technology ability over the long-haul,while environmental compensation helps reduce maintenance costs. • Wide 0.53 to 3.94%/ft. (1.7 to 12.35 %/m)smoke obscuration Like all KI Series detectors,the KI-PD is an intelligent device that • Uses Existing Wiring gathers analog information from its optical sensor, converting this . Automatic Device Mapping data into digital signals.To make an alarm decision,the detector's on-board microprocessor measures and analyzes sensor read- • Up To 250 Total Addresses Per Loop ings and compares this information to historical data. Digital filters e Two Levels of Environmental Compensation remove signal patterns that are not typical of fires,thus virtually eliminating unwanted alarms. • Two Levels of Dirty Detector Warning • Twenty Pre-Alarm Settings • Five Sensitivity Settings • Non-Volatile Memory • Electronic Addressing • Identification of Dirty or Defective Detectors • Automatic Day/Night Sensitivity Adjustment • Bicolor(Green/Red)Status Led • Standard, Relay, Fault Isolator,and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification Page 1 of 4 DATA s li e e T K85001-0646 Not to Dc used for:n staifat€on pur uses. Issue 1 Application Testing & Maintenance The KI-PD detects extremely small particles of combustion and Each detector automatically identifies when it is dirty or defective triggers an alarm at the first sign of smoke.Thanks to its high- and causes a"dirty detector"message.The detector's sensitiv- performance forward-scattering reflective response technology, ity measurement can also be transmitted to the loop controller,A the photoelectric smoke sensor responds quickly and reliably to sensitivity report may be printed to satisfy NFPA sensitivity mea- a wide range of fire types, especially slow burning fires fuelled by surements,which must be conducted at the end of the first year combustibles typically found in modern multi-use buildings. and every two years thereafter, The user-friendly maintenance program shows the current state Compatibility of each detector and other pertinent messages.Single detectors may be turned off temporarily from the control panel.Availability of The KI-PD detector is compatible with Kidde VS and VM series maintenance features is dependent on the fire alarm system used. panels. Accessories Installation Detector mounting bases have wiring terminals that are acces- KI Series detector bases mount sible from the"room-side"after mounting the base to the electrical ?ry box.The bases mount to North American 1-gang boxes and to to North American 1-gang boxes, , , 3-1/2 inch or 4 inch octagon __ ` ` �i 3/2 inch or 4 inch octagon boxes, 1/2 inches(38 mm)deep.They Self-locking tab also mount to European BESA and 1-gang boxes with 60.3 mm boxes,and to 4 inch square elec- - — fixing centers.The KI-SB4, KI-RB4, and KI-IB4 mount to North trical boxes 1-1/2 inches mm 38 ��; - �f 1i' ( ) ., t American 4 inch sq.electrical boxes in addition to the above deep.They mount to European boxes.They include the GSA-TS4 Trim Skirt,which is used to BESA and 1-gang boxes with 60.3 „£ - � I` cover the"mounting ears"on the base.The KI-ABST mounts to a mm fixing centers. See mounting _ LED Indicator 4 inch square box only. base installation and wiring for ' = more information. i'"^�:,. i'r `''�:,;•���} ��`�`5!::� ,;`.."^'^`��`�, j it; '�• -\;1,•��' �{-..„;! raid 1},E';4 ,� � ;� � I ' . � '�;�-',`�+`�' :"''��+ems t-��'� :•�Yy < Y � .y �'t Sensing and reporting technology KI-ABSTlr/LF KI-SB SB KI-IB KI-RB GSA-LED The microprocessor in each detector provides additional benefits- Audible Base Standard Base Isolator Base Relay Base Remote LED Self-diagnostics and History Log,Automatic Device Mapping,and Remote LED GSA-LED-The remote LED connects to the KI-SB Fast,Stable Communication. or KI-SB4 Standard Base only. It features a North American size Self-diagnostics and History Log-Each KI Series detector 1-gang plastic faceplate with a white finish and red alarm LED. constantly runs self-checks to provide important maintenance in- GSA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also formation.The results of the self-check are automatically updated be ordered separately to use with the other bases to help hide and permanently stored in the detector's non-volatile memory surface imperfections not covered by the smaller bases. Automatic Device Mapping-The loop controller learns where Sounder Bases-KI Series sounder bases are designed for use where localized or group alarm signaling is required. each device's serial number address is installed relative to other devices on the circuit.The mapping feature provides supervision • KI-ABST bases provide sounder capability to KI Series heat of each device's installed location to prevent a detector from being and smoke detectors.They are not intended for use with reinstalled(after cleaning etc.)in a different location from where it combination carbon monoxide detectors in Fire-plus-CO was originally. mode. • KI-ABDT bases provide sounder capability to KI Series Fast Stable Communication -On-board intelligence means less smoke and heat detectors,as well as carbon monoxide information needs to be sent between the detector and the loop detectors when used with a GSA-T3T4 Temporal Pattern controller.Other than regular supervisory polling response,the Generator. detector only needs to communicate with the loop controller when a KI-ABLT bases provide 520 Hz low frequency sounder it has something new to report. capability to KI Series smoke and heat detectors,as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator.The KI-ABLT is suitable for ap- plications requiring low frequency audible tones. Page 2 of 4 D A r A j rf C F T K85001-0646 1`:01 tc oe uS,:+d fGr itt,it+Erz;l+;r Puroo=•es, Issue 1 * T/n'rn| Wiring The detector mounting bases accept#18AYV8 (0J5mnf").#16 Audible Sounder Bases,Fire Mode (1.Omm2). #14AVVG(1.5mm2). and#12/WG(2.5mm2)wire sizes. AB4GTAB4G,AB4B'LF sounder bases Sizes#1OAVV6(1.Umn�)and#18AVYG075mm�)are preferred for ease nfinstallation. St�nuo,��eton�ormoae,��-��,�Y���4 m*ao� Output de ��ocr Default~Fire This io the basic mounting base Remote LED Volume Setting Cut/remove jumper for o"*" ~my^ m°�=uo for x]ddoK|Snheed�e�om. must not exceed C��m°v The GSA-LED Remote LED io jumper for m�nor / uo � ouppo�odby1h� not m° ..~Setting Default=Temporal 8�n� m�mo°|=p�� Term Description m."� 1 Not Used 0 x*m� exc. Not Used 4 DATA IN 4 Remote LED DATA IN * DATA IN mm o�w mw*m �__� _ ��,out 6 Remote LED 6 Not Used > o"m,m=m��"*"o", m Next Device From power supply ~�______� ~ ��������n��� ----����7 DATA OUT .,,"=m"°o"w," ",,�w"��� ' Data out Dam* ' | m""mmu°w ^�� hw/otorDetector Base,K�|2\K�iB4 �mmo��n��� ~ � ~ =previous device . This base includes u built-in line fault isolator for use on Class A circuits.A detector must bo installed for itto operate.The isolator base does not support the GSA-LED Remote LED. Wo[D'O[1s /K CG\Uf'DDS The isolator operates a°follows: ~ Thgoteotordoeenotopon� power, anononm mm the line mo- � finaofrequently cause power interruption,discuss further lators to open withinz3msoo safeguards with the local fire protection specialist. beginning on one side ° This detector does not sense fires in areas where smoke of the DATA 11 DATA OUT cannot reach the detector.Smoke from fires in walls, roofs, circuit nearest the loop ormn the opposite side of closed doors may not reach the controller,the isolators -----�DATA.om detector. close to providetho DATA/ww To Next Device next isolator down the From Signature Controller ° Photoelectric detectors have a wide range offire-sensing line with power or ioTerm Description capabilities and are best suited for detecting slow,smolder- 1 'when the isolator next 2 DATA IWOUT ingfirem. Vo�eahon dmmu.8moPe»aw8 �� 104 Not Used " |n Canada,install according 0xCAN/ULC'G524 Standard for mn*«. 5 Not Used6 DATA OUT the Installation of Fire Alarm Systems, C8AC22.1Canadian The process repeatsbeginning on1ho 7 NotUsed Electrical Code,and the local authority having jurisdiction. other side of the loop controller. ---��� Relay Detector Base,K|-RB' K|-RB4 Normally-�Open mally Open or Normally Closed operation is selected during installation.The dry contact is rated for 1 amp(pilot duty)@ supervised to avoid accidentally A L OUT jarring it out of position.The KI-RB DATJ1_ can be operated as a control > relay if programmed to do so at —IN(-) DATA CUT - This base includes a relay. Nor- FSignature Controller To Next D�Ice the control panel.The relay base_ - _--DevIco Term Description __ does not support GSA-LED 1 Normally Open Remote LED. CONTACT RATING] 2 DATA IWOUT 5 Not Used 7 DATA OUT K85001-0646 Dimensions K idde Technology that saves lives C"D 1MV11.10i 00 Contact us... Email: kdde.fire@fs.utc.com Web: kidde.corrVengineeredsystems 1016 Corporate Park Drive Mebane,NC 27302 Kidde is a registered mark in the United States and other countries. Q 2018 Walter Kidde Portable Equipment. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 51 pA Alarm current 68 NA Smoke Sensitivity Range UUULC:0.53 to 3.94%/ft.(1.7 to 12.35%/m)olascuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min(0 to 20 m/s) Wall mounting 12 in.(305 mm)max.from ceiling Compatible bases See Ordering Information Compatible detector testers Testif ire 1000,Testifire 2000 Operating environment 32 to 120OF(0 to 490C),0 to 93%RH,nonconclensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140OF(-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-§529,UL 268,UL 268A Ordering Information Catalog Description Ship Wt. Number lbs(kg) KI-PD Intelligent Optical Smoke Detector 0.4(0.16) Accessories KI-SB Detector Mounting Base-Standard KI-SB4 4-inch Detector Mounting Base c/w Trim Skirt Kl-RB Detector Mounting Base w/Relay KI-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2(.09) KI-IB Detector Mounting Base w/Fault Isolator KI-IB4 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt GSA-LED Remote Alarm LED(not for EN54 applications) KI-ABST Audible(Sounder)Base for Fire Detectors 0.3(0.15) Kl-ABLT Low Frequency Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) KI-ABDT Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) GSA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (0.04) GSA-TS Trim Skirt-(optional for non 4-inch bases) 0.1 (0.04) GSA-DMP Detector Mounting Plate 3.0(1.4) O Page 4 of 4 DA'fA SHEEI K85001-0646 NOt tO DC USA for msta Jati,,n puror,ses. issue 1 Intelligent Input-Output Kidde r E•L E C T R O N I C � ,A D D'S•R'E�S�S' N G�f Technology that saves lives Input Module.,:) S3424 GSA-MM1 & GSA-1AITM « f 7300-1483: 0115 FM a a9x vm d f e ��F se9�326?N ; C(I Overview Standard Features The GSA-MM1 Monitor Module and GSA-WTM Waterflow/Tam- • Monitor and waterflow/tamper applications per Module are part of Kidde's Signature Series system.They are Includes Alarm with delayed latching(retard)for waterflow intelligent analog addressable devices used to connect one or two applications. Supervisory, and Monitor. Class B normally-open Alarm,Supervisory,or Monitor type dry . Non-volatile memory contact Initiating Device Circuits(IDC).The function of the GSA- Permanently stores serial number,type of device,and job MM1 and GSA-WTM is determined by the factory loaded"person- number.Automatically updates historic information including ality code". hours of operation, last maintenance date,number of alarms The input modules gather analog information from the initiating and troubles, and time and date of last alarm. devices connected to them and convert it into digital signals. . Automatic device mapping The module's on-board microprocessor analyzes the signal and Each module transmits wiring information to the loop control- decides whether or not to input an alarm, ler regarding its location with respect to other devices on the The microprocessor in each module provides four additional ben- circuit. efits-Self-diagnostics and History Log,Automatic Device Map- . Electronic addressing ping,Stand-alone Operation and Fast,Stable Communication. Permanently stores programmable address;there are no switches or dials to set.Addresses are downloaded from a PC, or the SIGA-PRO Signature Program/Service Tool. • Intelligent module c/w integral microprocessor All decisions are made at the module allowing lower communication speed while substantially improving control panel response time. Less sensitive to line noise and circuit wir- ing properties;twisted or shielded wire is not required. • Ground fault detection by address Detects ground faults right down to the device level. • Designed for high ambient temperature operation Install in ambient temperatures up to 120OF(490C). Page 1 of 4 0 A 1"A S,,C�. ; K85001-0297 WA io bo mscr3 tor fwr,>o o—o. Issue c Application Installation The duty performed by the GSA-MM1 and GSA-WTM is de- The GSA-MM1 and GSA-WTM modules mount to North American termined by their factory assigned sub-type code or"Personality 2-1/2 inch(64 mm)deep one-gang boxes and 1-1/2 inch(38 mm) Code". deep 4 inch square boxes with one-gang covers and GSA-MP GSA-WTM NORMALLY-OPEN ALARM -DELAYED LATCH- mounting plates.The terminals are suited for#12 to#18 AWG ING(Factory set Personality Code 2)-Assigned to one circuit. (2.5 mm2 to 0.75 mm2)wire size. Configures circuit 1 for Class B normally-open Waterflow Alarm Kidde recommends that this module be installed according to lat- Switches.An ALARM signal is sent to the loop controller when est recognized edition of national and local fire alarm codes. the input contact is closed for approximately 16 seconds.The Electronic Addressing-The loop controller electronically alarm condition is latched at the module. addresses each module,saving valuable time during system GSA-WTM NORMALLY-OPEN ACTIVE-LATCHING(Factory commissioning. Setting complicated switches or dials is not set Personality Code 4)-Assigned to one circuit. Configures required. Each module has its own unique serial number stored circuit 2 for Class B normally open dry contact Supervisory and in its on-board memory,The loop controller identifies each device Tamper Switches.An ACTIVE signal is sent to the loop controller on the loop and assigns a"soft"address to each serial number. when the input contact is closed.The active condition is latched at If desired,the modules can be addressed using the SIGA-PRO the module. Signature Program/Service Tool. GSA-MM1 NORMALLY-OPEN ACTIVE-NON-LATCHING Personality codes are assigned by the factory. No user configura- (Factory set Personality Code 3)-Assigned to one circuit. tion is required for these modules. Configures circuit 1 for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors,etc.An ACTIVE signal is sent to the loop controller when the input contact Compatible electrical box is closed.The active condition is not latched at the module.Com- patibility The Signature Series modules are compatible only with Kidde's Signature Loop Controller. Wall plate,white Warnings & Cautions (1-gang) This module will not operate without electrical power.As fires fre- quently cause power interruption,we suggest you discuss further a safeguards with your local fire protection specialist. o d• mm Q• Compatibility These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform.They are compatible with VM, and Q VS Series control panels. Q Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance program shows the current state of each module and other perti- nent messages.Single modules may be turned off(de-activated) temporarily,from the control panel.Scheduled maintenance(Reg- ular or Selected)for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Availability of maintenance features is dependent on the fire alarm system used. Page 2 of 4 DATA sH E F T K85001-0297 Not to bn usoct te; Issue 1 Typical Wiring The module will accept#18 AWG(0.75mm2), #16(1,OMM2). #14 AWG(1.50mm2),#12 AWG(2.50mm2) wire sizes. Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance 0.1 uF per Circuit _ - —For Design Reference: Wire Size -` Maximum Distance to EOLR _ #18 AWG(0.75 mm2) _ #16 AWG(1.00 mm2) 4,000 ft(1219 m) _ #14 AWG(1.50 mm2) T #12 AWG(1.50 mm2) Typical N.O.Wlaterflow Contact Typical Supervisory Contact Typical N.O.Monitor Contact 1 INPUT 1 INPUT 2 1 Ql Q2 Q4 Style B(Class B) 1 1 1 T82 TB2 8 7 UL/ULC Listed UL/ULC Usted Style B(Class B) 8 7 5 5 0 0 0 47KQ EOL 0 0 o UL/ULC Listed 47KQ EOL pl Q2 A47KQ EOL Red LED Green LED Red LED ® ® Green LED (Alarm/Active) ® ® (Normal) (Alarm/Active) 4 3 2 t (Normal) 4 3 2 1 TB1 TBl {(DATA IN(+) DATA OUT(+)l} j( DATA IN(+) DATA OUT(+) `DATA IN(-) DATA OUT(-)1 ` DATA IN jo DATA OUT(-) From Signature Controller To Next Device From Signature Controller To Next Device or Previous Device Q or Previous Device Q Model GSA-WTM Model GSA-MM9 Notes Al Maximum 25 ohms resistance per wire. A Maximum#12 AWG(2.5mm2)wire. Min. #18(0.75mm2) ARefer to Signature Loop Controller Installation Sheet for wiring specifications. A Maximum 10 Vdc Q 350pA. 5) All wiring power limited and supervised. 6) This module will NOT support 2-wire smoke detectors. Page 3 of 4 CA I A 3;r E L; r- K85001-0297 Not tO bO. uSC:J for in St AUl 4!ion pur;,oL;R.S. Issue 1 Specifications Catalog- alog Number � GSA-MM1 GSA-WTM Description Monitor Module Waterflow/Tamper Module Type Code 48(factory set 49(factory set Technology that saves lives ____ _ _ I personality code 3) _ personality code 2,4) _ Address Requirements j Uses One Module Address Uses Two Module Addresses Contact us... Operating Current Standby=250pA; Standby=396pA; — Email:kidde.fire@fs.utc.com Activated=400pA Activated=680pA Web: Kidde.com/EngineeredSystems Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Construction&Finish i High Impact Engineering Polymer one-gang front plate-White _ Kidde is a UTC brand. Storage and Operating _ Operating Temperature:320F to 120OF(0°C to 49°C) 1016 Corporate Park Drive Environment i Storage Temperature:-40F to 140OF(-20°C to 60°C) Mebane,NC 27302 i Humidity:0 to 93%RH LED Operation I On-board Green LED-Flashes when polled ©2016 United Technologies Corporation. i On-board Red LED-Flashes when in alarm/active All rights reserved. Both LEDs-Glow steady when in alarm(stand-alone) Compatibility Agency Listings j Use With Signature Loop Controller UL,ULC,CSFM,MEA Mounting North American 2-1/2 inch(64 mm)deep one-gang boxes and 1-1/2 inch(38 mm)deep 4 inch square boxes with one-gang covers and GSA-MP mounting plates. Ordering Information Catalog Description Ship Wt (dumber Ibs(kg) GSA-MM1 Monitor Module-UL/ULC Listed 0.4(.15) _ GSA WTM Waterflow/Tamper Module UL/ULC Listed Accesories _ 27193 11 Surface Mount Box-Red,1-gang µ 1.0(0.6) — 27193-16 Surface Mount Box-White, 1-gang MFC-A Multifunction Fire Cabinet 7.0(3.1) — __ -Red,supports Signature Module Mounting Plates _ GSA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) a Page 4 of 4 D A i SHEET K85001-0297 Not to 's;i: traC?rf fcz }�ur;:?os,;s. Issue 1 Intelligent Input-Output ELE10T_R0N10 A O D R E"S_S I N G, Technology that saves lives Input/output Modulu.z.) ----------- GSA-10, GSA-M10 MEA 7300-1483: 0154 Overview Standard Features GSA-10 and MIO Input/Output Modules are intelligent analog • 10 modules in one addressable devices that form part of Kidde's Signature line of Multiple applications including normally-open or normally- products.The actual operation of the GSA-10 and MIO is deter- closed alarm relay and latching or non-latching alarm inputs. mined by the"personality code"selected by the installer,which The installer selects one of up to 10 personality codes to be is downloaded to the module from the Signature loop controller downloaded from the loop controller. during system configuration. • Adjustable time delays Depending on their assigned personality, Input/Output Modules User sets the expected response time(5- 120 seconds)for provide the following modes of operation: maximum flexibility. •Output with monitor input(two personalities) Plug in(UIO)or standard 1-gang mount •Input/programmable output(eight personalities) UIO versions allow quick installation where multiple modules Each 10 module requires one module address. are required.The 1-gang mount version is ideal for remote locations that require a single module. • Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop, • Electronic addressing Programmable addresses are downloaded from the loop con- troller,a PC,or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. • Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties;twisted or shielded wire is not required. Page,of 6 r;A T x s H E F K85001-0533 a=a,d to: :1;n;.,1',,ition Issue 1 ^ � /\C}Dr�tOD|' ' Personality �yuodes� A�rm�putondM��re�youtput Application' "~~" Pa�onn�y code 33uon8gu�o�emodu�aounorma0�opan. �hw��A'|�mou��toao�md��No��Amehounone��nQ dry-contact relay and an alarm latching input for Class Bcontact electrical box, making it ideal for locations where only one module initiating devices.When the input contact of the initiating de- is required.Separate KO and data loop connections are made t» viine changes state,the|K}module sends an alarm signal tothe each module. Signature loop controller and the alarm condition io latched a1the The GGA'80I1Ois part of the U|O family of plug-in Signature Series module. modules. |t functions identically to the G8A-|D.but takes ad«an' Personality code 34:Alarm input and m'C'relay output tagoof the modular flexibility and easy installation that character- Personality code 34 operates the same uo personality code 33. izo all U|0 modules.Two-and six-module U|Omotherboards except that the output io configured aoa normally closed,dry- are uvui|ob|o.The000ana000mmoda1eindividualhoemforeaoh contact relay. bn'board module,nr risers that are shared Uy any combination cf its U|O modules.All Wring connections are made 1oterminal Personality code 85:Delayed alarm input and N.D.relay blocks on the motherboard. U|O assemblies may be mounted in output Kidde*nc|oou*m. Personality code 35 configures the module auamxmu|w-opon. dry-contact relay and an alarm latching input for Class Bcontact initiating devices.This personality requires that u change inthe . state of the initiating device be maintained for approximately 1O Electronic Addressing seconds before the 1/0 module sends an alarm signal to the Sig- The loop controller electronically addresses each module saving nature loop controller.The alarm condition is latched at the mod- valuable time during system commissioning.Setting complicated u|e. Use only with non'mtarded. N.Q.xmatorflmm alarm switches. switches or dials io not required. Each module has its own unique Personality code 3O:Delayed alarm input and N'C,relay serial number stored in its^nn-buardmemory/' The loop control- . output |eviUon�fioa each de�oeon the loop and assigns a^o»ftaddress Personality code 8O operates the same on personality code 35. 1u each serial number. |f0ooi/edthemodu|eoounbeaddne000U ' except that the output is configured as a normally closed,dry- using the SIGA-PRO Signature Program/Service Tool. contact relay.Use only with non-netevded. N.C.vvat*rflmwalarm switches. P8B��8|'tv (��H�S p�mon�dx�de3�Am�ainp��on'|�o km0}andN'D- ' ''^z Codes relay output A signature module requires a Signature loop controller todown- Personality code 37configures the module enononnu|k+npen. load the personality code that determines how it will operate.The dry-contact relay and an active input for Class B contact initiating Input/Output Module provides personality codes 31 tUmugh4O. devices.When the input contact uf the initiating device changes For personalities O3 through 4O.the outputs must beprogrammed state,the|X}module sends an active signal U»the Signature loop Lobo activated by the panel. controller.The active signal does not latch, and restores when the Personality code 31 (default):N.O.relay output with monitor input device returns to its normal state.Typically used for monitor- input ingN.O.faoa,dampers,doom.etc. Personality code 31 configures the module aounormally-open Personality codes 38:Active input(noo-|muohiug)and 0.C. output relay contact that requires a maintained dry contact input relay output activation.The activation must take place within a time period Personality code 88 operates the same ao personality code 37. defined by the user(15 seconds default;5-120 seconds*electa except that the output is configured anu normally closed,dry+ b\e)uftertheou4mtoircuitadivation. |fthofi»aalunnoontrdPane| contact relay.Typically used for monitoring N.C.fans, dampers, does not receive a monitor input within the specified time, itwill doors,etc. generate a trouble condition. Personality code 39:Active input<|otching>and N.O'ne|oy Personality code 3D: N.C.relay output with monitor input output Personality code O2 operates the same ao personality code 31. Personality code 89 configures the module aaunormo|l+opon. except that the output ia configured mma normally closed, dry- dry-contact relay and an active latching input for Class Bcontact contact na|u9 initiating devices,When the input contact nf the initiating device changes state,the|/]module sends on active signal Vothe Signature loop controller and the active condition ia latched mthe module. Personality code 40:Active input(|amching)and N.C.relay output Personality code 40 operates the same ao personality code 88. except that the output ia configured aoa normally closed,dry- contact reloy. K85001-0533 ~ � |Dsfn||aGOD Warnings & Cqot'C)08 The GSA-10:modules mount to North Amedcan 21/2 inch(64 mm) This module will not operate without electrical power.As fires fre- deep1-gang boxes and11/2 inch(38nm)deep 4inch square quently cause power interruption,we suggest you discuss further boxes with 1-gang covers.They also can bnsnapped directly to safeguards with your fire protection specialist. the GSA-MP mounting plates.The terminals are suited for#12to #18/WG(2.5mmctoO.75mm')wire size. Kidde recommends that these modules bo installed according to m Motherboard latest recognized edition of national and local fire alarm codes. 6-32 Testing & Maintenance - Thompdu|e's automatic self-diagnosis idenhfioawhen itiadofeo ow^ive dve and causes u1mub!a message.The user-friendly maintenance Module ="=' pmgramshows the cunentstate of each module and other perti- nent- meaaagea.Single modules may bo turned off(de-activated) ping tempomh|X0nmthe ounUnpanel. U shers V Scheduled maintenance(Regular orSo|o��oc0 for pmparsystem U^—»�" or electrical operation should bo plannedtn meet the requirements ufthe Authority Having Jurisdiction k\H4 Refer to current NFPA72and ULCCAN/ULC506 standards. GS/-|NVO:mount the U\QxR motherboard inside u suitable K]ddo enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the (�O�OD��'��U'f« mod�o*o�om�hodboa�w�h the oap�voscrews.YY�ng con ' Compatibility '~'''^' nooLiono are made ho the terminals un the motherboard(see wiring These modules are part of Kidde's Signature Series intelligent pro- diagram).U1OxR motherboard terminals are suited for#12 to#18 0000ing and control platform.They are compatible with NN.and /WG(2.5mm'toD.75mm2)wire size. VS Series control panels, K85001-0533 Typical Wiring (GSA-10) Modules will accept#18 AWG to#12 AWG(0,75MM2 to 2,50mmg wire sizes.Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications, Input/Output Module (personality codes 31 -40) Wiring Notes: N.C.or N.G. & Maximum 25 Ohm resistance per wire. Ll N.O.or N.G. UUULC Listed #12 AWG(2.5 mml max;018 AWG(0.762)mm min. 47 kW EOL Zis 10 Vdc @ 350 mA,max. See the loop controller installation sheet for wiring AAAA specifications. Input/Output Module System programming determines whether contact TB2 will be normally-open(N/0)or normally-closed(N/C). 8 7 6 5 Supervised and power-limited. 0 0 0 zE Power-Grafted unless connected to a nonpower- Red LED(Active/AJar Green LED(NormalfTrouble) limited source.If the source is nonpower-limfted, A Jar Input/ Output rG,i.&en LED(TNO.i 0 0 eliminate the power-limited mark and: 1 . Maintain a 1/4-inch(6.4 rnm)space from power- 4 3 2 limited erring. T81 or • Use FPL,FPLR,FPLR or an equivalent cable in AAALt accordance with the National Electric Code. (+) t I The Nomex isolation barrior separates power-limited From loop controller Data In Data out To next device and nonpower-limited wiring.Watch out for the sharp Data out(.,I or previous device Data in Data out(+)I corners during Installation and maintenance. Typical Wiring (GSA-MIO) Modules will accept#12 AWG(2.5mm2),#18 AWG(0.75mM2), #16(1.0MM2),and#14 AWG (1.50mM2)wire sizes.Note:Sizes#16 AWG (1.0mm2)and#18 AWG(0.75MM2)are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Input/Output Module (personality codes 31 -40) Wiring Notes: ZL Maximum 26 Ohm resistance per wire.Maximum > T81 through T86 circuit capacitance of 0.1 mF. Green LED!(NormalfrrMilble Input/Output Module C 10 Vdc @ 350 mA,max. Red LED(Active/Al 1234 1 1 U102R or U106R motherboard See the Signature loop controller installation sheet for ASA wiring specifications. Data In ZL Supervised and power-limited 0 uL/uLc listed 47 kW EOL Data 4 0 3 Circuit 2 0 System programming determines whether contact 1 T87 will be normally-open(IN/0)or normally-closed(N/Q. Data Out+ Power-limited unless connected to a nonpower- & 4 Nol"ections required limited source.If the source is nonpower-limited, - 3 for M connections other modules eliminate the power-limited mark and: 2 May require connections. Maintain a 1/4-Inch(6.4 mm)space from power- TB15 limited wiring. PO �Remove motherboard Jumpers. or • Use FPL,FPLR,FPUP or an equivalent cable in TE18 through T81 3-� 1234 accordance with the National Electric Code. 8 See the U102R or U106R Installation sheet for additional instructions about the separation of power- Dry contact relay limited and nonpower-limited wiring. Page 4 of 6 D A")A 5 H r ET K85001-0533 r k,j 1r, t)c7 ir_,, Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from Kidde is Fast Stable Communication-Built-in intelligence means less informa- an entire family of multi-sensor detectors and mounting bases,multiple- tion needs to be sent between the device and the Signature Data Controller function input and output modules,network and non-network control (SDC).Other than regular supervisory polling response,Signature devices panels,and user-friendly maintenance and service tools.Analog informa- only need to communicate with the SDC when they have something new tion from equipment connected to Signature devices is gathered and con- to report.This provides very fast control panel response and allows a lower verted into digital signals.An onboard microprocessor in each Signature baud rate(speed)to be used for communication on the circuit.The lower device measures and analyzes the signal and decides whether or not to baud rate offers several advantages including: input an alarm.The microprocessor in each Signature device provides four additional benefits-Self-diagnostics and History Log,Automatic Device - Less sensitivity to circuit wire characteristics. Mapping,and Fast,Stable Communication. - Less sensitivity to noise glitches on the cable. Self-diagnostics and History Log-Each Signature Series device con- - Less emitted noise from the data wiring. stantly runs self-checks to provide important maintenance information.The results of the self-check are automatically updated and permanently stored -Twisted or shielded wiring is not required. in its non-volatile memory.This information is accessible for review any Diagnostic LEDs-Twin LEDs on most Signature devices provide visual time at the control panel,PC,or using the SIGA-PRO Signature Program/ indication of normal and alarm-active conditions.A flashing green LED Service Tool. shows normal system polling.A flashing red LED means the module is Automatic Device Mapping-The Signature Data Controller(SDC)learns in alarm-active state.Both LEDs on steady indicates alarm-active state- where each device's serial number address is installed relative to other de- standalone mode. vices on the circuit.The SDC keeps a"map"of all Signature Series devices Testing&Maintenance-Automatic self-diagnosis identifies when a connected to it.The Signature Series Data Entry Program also uses the Signature device is defective and causes a trouble message.The user- mapping feature.With interactive menus and graphic support,the wired cir- friendly maintenance program shows the current state of each device and cults between each device can examined.Layout or"as-built"ctaps),device types ann drawingd their address other pertinent information.Single devices may be turned off temporarily,from information showing branch wiring the control panel.Scheduled maintenance(Regular or Selected)for proper are stored on disk for printing hard copy.This takes the mystery out of the system operation should be planned to meet the requirements of the Authority installation.The preparation of"as built"drawings is fast and efficient. Having Jurisdiction(AHJ).Refer to current NFPA 72 and ULC CAN/ULC Most Signature modules use a"personality code"selected by the installer 536 standards. to determine their actual function.Personality codes are downloaded quality and Reliability-Kidde Signature devices are manufactured in from the SDC during system configuration and are indicated during North America to strict international ISO 9001 standards.All electronics uti- device mapping. lize surface mount technology(SMT)for smaller size and greater immunity to RF noise.A conformal coating is used for humidity and corrosion resistance. Specifications Model GSA-10 GSA-MIO Description Standard Mount Input/Output Module Plug-in(UIO)Input/Output Module North American 2'/2 inch(64 mm)deep one-gang boxes Mounting and 11/2 inch(38 mm)deep 4 inch square boxes with one- Plugs into U102R or U106R Motherboards only. gang covers and GSA-MP mounting plates Current Standby I 250 pA Activated 430 pA _Relay type Form A or B Contact ratings(pilot duty) _ 24 Vdc:2 A._120 Vac:0.5 A (Not rated for capacitive loads.) T Initiating Device Circuit EOL(end-of-line)resistor UL/ULC listed 47k Ohm Max.circuit resistance 50 Ohm(25 Ohms per wire) Max.circuit capacitance 1 0.1 pF -Wiring Terminations i Suitable for#12 to#18 AWG (2.5 mm2 to 0.75mm2) Personality Codes Ten Selectable Codes Available _Address Requirements ; Uses One Module Address Operating Voltage ! 15.2 to 19.95 Vdc(19 Vdc nominal) Construction High Impact Engineering Polymer Environment Operating Temperature 32°F to 120°F(0°C to 49°C) Storage Temperature i -4°F to 140'F(-20°C to 60'C) Humidity j _ 0 to 93%RH LED Operation On-board Green LED-Flashes when polled;On-board Red LED-Flashes when in alarm/active Compatibility Use GSA-10 and GSA-MIO with:Signature Loop Controller Plug GSA-MIO into:U106R or U102R Motherboards Agency Listings UL,ULC,MEA,CSFM Page 5 of 6 Cl A I A SHEET K85001-0533 W-1 io :'x: tor snl't;o irOint,j1U r;?08 Bf1. issue 1 Ordering Information ag4r `` Kidde Catalog Ship Wt. Number Description Ibs k � g) GSA-10 Input/Output Module(Standard Mount)-UVULC Listed 0.34 Technology that saves lives (0.15) GSA-MIO Input/Output Module(Plug-in)-UVULC Listed 0.22 Contact us... — Email:kidde.fire@fs.utc.com Related Equipment Web: Kidde.com/E`naineeredSystems 27193-11 Surface Mount Box-Red,1-gang 2(1.2) 27193-16 Surface Mount Box-White,1-gang 2(1.2) 1016 is a UT Corporate brand.e Park Drive GSA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32 016 Mebane,NC 27302 -Two Module Positions _ (0.15) GSA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62 ©2016 United Technologies Corporation. -Six Module Positions (0.28) All rights reserved. MFC-A UL listed cabinet for mounting releasing modules,red with white 7,0(3.1) "FIRE". .� GSA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) 0 Page 6 of 6 LI A)n :,H E E T K85001-0533 m ia:i to uc u;',od 30r il,t•,ta.L'9ti4P1 {7iz7»4Se.. ISSUe 1 I: Intelligent Initiating go M AV i E L E C T R O N I C 'l me - -- MOM" A D b'R'E-8'$-1 R G J Technology that saves lives 11--%1te11ig1/E5Nv1 -%1t Duct use . u Smoke Utt tOr GSA-SD �Y ' .. 4 "gam .. ...rti=`n••m:e.-¢mrvwM'Ftaaens+Y9u'«T._ a MEA 3290173 5353 Overview Standard Features The Kidde SuperDuct Signature Series smoke detector is the most • Less than 2"deep for easy installation and applications where advanced and most reliable device in its class. Designed for easy space is tight installation and superb reliability,SuperDuct represents the perfect e -20°F to 158°F(-29°C to 70°C) operating range with 100 ft/ balance of practical design and advanced technology. min.to 4,000 fUmin air velocity rating assures reliability under SuperDuct detectors feature a unique design that speeds instal- harsh environmental conditions lation and simplifies maintenance. Removable dust filters,confor- . Status LEDs remain visible through clear assembly cover mally coated circuit boards,and optional water-resistant gaskets keep contaminants away from components, ensuring years of • Cover monitor switch for added security trouble-free service.When cleaning is required,the assemblies . Standard sampling tube spacing for easy drop-in migration come apart easily and snap back together in seconds. from other detectors A Signature Series photoelectric sensor is incorporated into • Sampling tube can be installed with or without the cover in the design of each GSA-SD duct smoke detector.This sensor place and can be rotated in 45-degree increments to ensure inherits the power and benefits of this exceptional line of intelligent proper alignment with duct airflow devices. • 15.2 to 19.95 Vdc operation Signature Series sensors gather analog information from their • Magnet-activated test switch smoke sensing elements and convert it into digital signals.The sensor measures and analyses these signals and compares the • One Form C auxiliary alarm relay for controlling ancillary equip- information to historical readings and time patterns to make an ment(e.g„ HVAC controls) alarm decision.Digital filters remove signal patterns that are not • No special tools required for easy access to field connections typical of fires,which virtually eliminates unwanted alarms. • Signature Series intelligence WARNING: Duct detectors have specific limitations. Duct detectors are not a • Environmental compensation with differential sensing for reli- substitute for an open area smoke detector.Duct detectors are not a substitute able, stable, and drift-free sensitivity for early warning detection or a replacement for a building's regular fire detection system.Smoke detectors are not designed to detect toxic gases which can build up • Wide 0.79%to 2.46%obscuration/ft.smoke sensitivity to hazardous levels in some fires.These devices will not operate without electrical power.As fires frequently cause power interruptions,Kidde suggests you discuss • Identification of dirty or defective detectors further safeguards with your local fire protection specialist. Page 1 of 4 0 a.Y A 3 11 L E i K85001-0584 Not It> Ibu u&^fS for oi,,,i<'aii,a:;f}n issue 1 Application The sampling tube may be installed from either the duct side of SuperDuct detectors are ideally suited to duct smoke detection the assembly or from inside the sensor compartment,as preferred applications where early indication of combustion is required within by the installer. (The exhaust tube must be installed from the ductside.)Sampling tubes may be rotated in 45-degree increments so the confined space of ventilation ductwork. Its primary purpose that air-holes can be aligned to allow the unit to be mounted at is to provide early warning of an impending fire and to prevent virtually any angle relative to the air flow. smoke from circulating throughout the building. It is typically used to detect smoke in the supply side of the HVAC system but can In installations where the duct smoke detector's controls and indica- provide supervision of the return side as well. tors are hidden from view,a remote test station or an LED indicator ----------------- ---------- can be connected to the detector to provide these functions. Protected premises Remote i Remote Test Stations Alarm relay test I output stalion I t Labor-saving Remote Test/Reset stations provide alarm testing from the convenience of a remote I —' location.Tests can be performed quickly and safely Ddetec or e Ratlrm -without having to climb to the roof. Magnetically- HVAC�r - operated and key-operated one-gang models are unit _ ; -- --- available.Signature SuperDuct detectors are also = i Duct d eclare Supply l compatible with GSA-LED remote alarm LED. air i �- -- -- - i Air velocity in the duct as low as 100 ft/min. maintains adequate j Alarm relay air flow into the sensor smoke chamber through air holes in the air Remote output test sampling tube and discharges through the exhaust tube.Su- FACP station perDuct air sampling tubes must be installed with the inlet holes facing the airstream. Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be SuperDuct detectors continually sample air flow in the HVAC duct mounted in virtually any angle relative to the airflow. and initiate an alarm condition whenever smoke is detected. An SuperDuct sensors are engineered to operate optimally under the alarm is activated when the quantity(percent obscuration)of harsh environmental conditions frequently found in HVAC duc- combustion products in that air sample exceeds the detector's twork. Nonetheless, before installing the detector,test the duct sensitivity setting. air velocity,temperature,and humidity to verify that it is within the operating range of the SuperDuct detector. Consult the SuperDuct Signature Series Intelligence installation sheet for details. Like all Signature detectors,the GSA-SD features electronic ad- dressing and issues a dirty sensor warning when it reaches its Dimensions preset limit.The dirty sensor warning indicates the sensor is op- erating within its specified limits but is in need of servicing.When 8.70 in(22.1 cm) 8.15 in(20.7 cm) the detector's ability to compensate for environmental changes 7.75in(19.7 cm) has reached its limit,the duct smoke detector signals a trouble 3.OBIn(7.B2Cm) (;..60- condition. The GSA-SD also uses differential sensing to prevent gradual environmental changes from triggering unwanted alarms.A rapid change in environmental conditions,such as smoke from a fire, causes the detector to signal an alarm state, but dust and debris accumulated over time does not change alarm sensitivity. Each Signature Series SuperDuct detector contains a microproc- essor that performs comprehensive self-diagnostics and stores the results in nonvolatile memory.Stored results include details 228 in such as hours of operation, last maintenance date, and number (5.78 cm) of alarms and troubles.This information can be retrieved and reviewed when desired. Detector Configuration ; 5.45 in The detector assembly cover provides easy access to the smoke (13.84—) sensor, its wiring connections,sample and exhaust tubes,and the j smoke chamber itself. 0 0 0 0 Air enters the detector's sensing chamber through a sampling tube(ordered separately)that extends into the duct and is directed back into the ventilation system through an exhaust tube(in- I 1.90in eluded).The difference in air pressure between the two tubes pulls i (4.83 cm) the sampled air through the sensing chamber.When a sufficient amount of smoke is detected in the sensing chamber,the detector initiates an alarm. 1.38 in 5.40 in ~(3.51 un) (13.72 cm) �!o n C o Page 2 of 4 C)A t'A S -i E E 7K85001-0584 fr} }f': Lc issue 1 Assembly High-humidity environments Sampling tube Detector socket I Use the SD-PH Protective Housing when installing SuperDuct Exhaust tube e 0 + detectors in high-humidity environments.The SD-PH is a weather- socket ized housing that prevents condensation on the device by insulat- ing the detectors and providing circulated air from the monitored HVAC duct.The SD-PH also adds a layer of protection against ® physical damage to the unit. Exhaust tube i } e Thin i gasket f Think gasket Coupling Duct Detector SD-PH Sampling tube Protective (ordered separately) Housing 0 8 Plug Mounting Rear View �-- HVAC duct Airflow n �t Hinged Detector Cover Housing ` air tube 1., Housing Detector Sampling \� �' ° ' air tube conduit holes tube �I e The SD-PH is easy to install and service.The hinged and transpar- ent cover provides ready access to the detector,while keeping its f status indicators visible at all times. #10 sheet metal screw(2X) Note: The SD-PH Protective Housing is weatherized against out- Wiring door air, but it is not intended for direct outdoor exposure. Auxiliary equipment r P SIGA-LED[1] Alarm ®®® [1] No more than one remote test station or LED indicator can be connected to or the detector at the same time.Wiring q r 17 16 15 is unsupervised.Maximum wire Alarm resistance is 10 ohms per wire. Z SD-TRK Test or SD-TRM[1] _ 3 - - --.. Data Out(-) = Data Out(+) ' Data In(+) i '."•:__ ,�y .: \ -__�r -_ Data In t-) ®®®®®IS)®(S _ ° 0 0 a 14 13 12 11 10 9 8 7 Power indicator Alarm indicator Page 3 of 4 D A FA 53 11 E T r K85001-0584 No to, t)c used {e! to In ion ;iuraes,;a. Issue 1 gM H T Specifications, detector Specifications, test stations y:>' ® Remote Test/Reset Stations provide alarm test,trouble gb;r 8.70 x 5.45 x 1.90 inches a Dimensions (221 x 138 x 48 mm) indication,and reset capability from a remote loca- re Wire size 14 to 22 AWG - tion.They include a one-gang plate,momentary SPST _ switch,red alarm LED,and terminal block.Magnetically- Detection Photoelectric operated models(TRM)or key-operated models(TRIQ method (light scattering principle) are-available. - --- Compatible North American 1-gang box 100 to he re aired and ri Standard 4-in square box, Contact us... Air velocity electrical ratingmeets the required minimum 1-1/2 inches deep,with Email:kidde.fireCfs.utc.com air pressure differential boxes 1-gang cover Web: Kidde.comlEnaineeredSystems Air pressure 0.005 to 1.00 Inches of LED indicators Alarm(red) differential water __--_ LED type Clear lens 1016 is a UT brand. 0.79 to 2.46%/ft 016 Corporate Park Drive Sensitivity _Wire size_ 14 to 22 AWG _ obscuration Mebane,NC 27302 es ---- Resistance per Alarm test 5 seconds wire 10 Ohms,max. ©2016 United Technologies Corporation. response time Current All rights reserved. LED indicators Alarm(red),Power(green) See controller specifications requirements Unsupervised and power- LED circuit Voltage:3 Vdc,max. limited ratings Current:30 mA,max. _ Common Quantity: 1 Switch ratings Voltage:125 Vdc,max. alarm relay Type:Form C (SD-TRK) Current:4 A,max. Ratings:2.0 A at 30 Vdc - (resistive) Switch ratings Voltage:200 Vdc,max. Operating (SD-TRM) Current:0.5 A,max. voltage 15.2 to 19.95 Vdc SuperDuct conventional 9_ _ Compatible two-wire and Signature duct Operating Standby:45 NA Alarm:45 detectors smoke detectors current pA Inrush:1 mA Standalone -- -4°F to 158°F -20°C to alarm:18 mA Operating Temperature(UL):-20 to environment 70°C)Humidity:93%RH, 158°F(-29 to 70°C). _ noncondensing Operating Temperature(ULC):-4 to Storage -4 to 140°F(-20 to 60°C) environment 120°F(-29 to 49°C) temperature Relative humidity:10 to Agency listings UL,ULC,MEA,CSFM 93%,noncondensing Agency UL,ULC,CSFM,FM,MEA listings Ordering Information Catalog Number Description Ship Wt.,lb.(kg) GSA-SD Intelligent SuperDuct Detector 2.4(1.1) Accessories S_D-T8 8-inch sampling tube _ -� 0.5(0.2) SD-T18 18-inch sampling tube _1.5(0.7) SD T24 24-inch sampling tube 2.7(1.2) SD-T36 36-inch sampling tube 3.0(1.4) SD-T42 _ 42-inch sampling tube _ 3.5(1.6) _ SD-T60 60-inch sampling tube 5.8(2.6) SD-T78 78-inch sampling tube 7.5(3.4) ----- ------ SD-T120 120-inch sampling tube 11.5(5.2) SD-PH Protective housing for high humidity environments 5.5(2.5) GSA-LED Remote alarm LED 1.0(0.5) SD-TRM Remote test station,magnetic _ 1.0(0.5) SD-TRK Remote test station,keyed 1.0(0.5) SD-VTK Air velocity test kit(stoppers only,etc) 1.0(0.5) SD-GSK Cover gasket kit_ _ 0.5(0.2) SD-MAG Test magnet kit 0.5(0.2) GSA-SDPCB Replacement PCB/Signature sensor kit 1.0(0.5) 0 Page 4 of 4 D .I-A �<H E E- K85001-0584 rn Not to 's;i: to Issue 1 b ® i<i :,i '.:•.;._:;,; Intelligent Initiating Devices Fw ' d e L E- E C T R O N I C ¢ -- United Te4fi*kqie,s, sa ' A D.D R'ETS S I,N Gi Technology that saves lives Intelligent Heat ,� Detectors ?-- �00 . _ KI-HRD, KI HFD i / O t� 1 S853 k _ KI-HFD shown Overview Standard Features The KI Series smoke detectors bring advanced sensing technol- Note:Some features described here may not be supported by ogy to a practical design that increases efficiency,saves installa- all control systems. Check your control panel's Installation and tion time,cuts costs,and extends property protection capabilities. Operation Guide for details. Continuous self-diagnostics ensure reliability over the long-haul, • Next generation heat sensing technology while the latest thermister technology makes these detectors ideal wherever dependable heat detection is required. • 135°F(57°C)fixed temperature alarm point(HRD and HFD) The KI-HRD is an intelligent fixed temperature/rate-of-rise fire • 15°F(8.3°C)per minute rate-of-rise alarm point(HRD) detector. It monitors the temperature of the surrounding air and . Uses existing wiring analyzes the data from the sensor to determine whether to initiate an alarm.The rate-of-rise heat function quickly detects a fast, • Automatic device mapping flaming fire.The fixed-temperature heat function detects fire when . Sensor Markings Provide Easy Testing Identification the air temperature near the detector exceeds the alarm point. The KI-HFD is an intelligent fixed-temperature heat detector that • Up to 250 total devices per loop contains a fixed-temperature heat sensor rated at 135°F(57.2 • Non-volatile memory °C). It does not have a rate-of-rise function.The heat sensor moni- . Electronic addressing tors the temperature of the air in its surroundings and the detector analyzes the data to determine when the air temperature near the Bicolor(green/red)status LED detector exceeds the device's alarm point. • Cover marking for easy identification during testing • Standard, relay,fault isolator, and audible mounting bases • 50 foot(15.2 meter)spacing Page 1 of 4 D r,r T 7€F€_ r K85001-0647 Pic! W bo usC'C1 f or iW,0, 0:1Z,t!ar,puf!)D-,..,. Issue 1 Application Accessories The KI-HRD combination fixed temperature/rate-of-rise heat de- Detector mounting bases have wiring terminals that are acces- tector provides a 15 of(9°C)per minute rate-of-rise heat sensor sible from the"room-side"after mounting the base to the electrical for the detection of fast-developing fires, as well as a 135°F(57°C) box.The bases mount to North American 1-gang boxes and to fixed temperature sensor for slow building-fires.The KI-HFD fixed 3/2 inch or 4 inch octagon boxes, 1/2 inches(38 mm)deep.They also mount to European BESA and 1-gang boxes with 60.3 mm temperature detector provides a 135°F(57°C)fixed temperature fixing centers.The KI-SB4, KI-RB4, and KI-IB4 mount to North sensor for slow building-fires. American 4 inch sq.electrical boxes in addition to the above boxes.They include the GSA-TS4 Trim Skirt,which is used to cover the"mounting ears"on the base.The KI-ABST mounts to a Compatibility 4 inch square box only. The KI-HRD detector is compatible with Kidde VS and VM series �,�,-^.��.;; -� � ''�� ;%;,,��• � ;',��;.� { ; Installation ° d _r.: u KI Series detector bases mount _ KI-ABST/T/LF KI-SB KI-IB KI-RB GSA-LED ^ Audible Base Standard Base Isolator Base Relay Base Remote LED to North American 1-gang boxes, q, %. 3-1/2 inch or 4 inch octagon ^» a = Remote LED GSA-LED-The remote LED connects to the KI-SB boxes,and to 4 inch square elec- - —self-locking tab or KI-SB4 Standard Base only. It features a North American size trical boxes 1-1/2 inches(38 mm) x" ` t.11 1-gang plastic faceplate with a white finish and red alarm LED. deep.They mount to European - GSA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also BESA and 1-gang boxes with 60.3 Cr: . be ordered separately to use with the other bases to help hide mm fixing centers. See mounting '} "- IFo Indicator surface imperfections not covered by the smaller bases. 9 g ;. =�� r base installation and wiring for = " Sounder Bases-KI Series sounder bases are designed for use more information. where localized or group alarm signaling is required. • KI-ABST bases provide sounder capability to KI Series to heat and smoke detectors.They are not intended for use Sensing and reporting technology with combination carbon monoxide detectors in Fire-plus-CO mode. The microprocessor in each detector provides additional benefits- Self-diagnostics and History Log,Automatic Device Mapping, and smoke T bases provide sounder capability KI Series s Fast,Stable Communication. smoke and heat detectors,as well as carbonn monoxide detectors when used with a GSA-T3T4 Temporal Pattern Self-diagnostics and History Log-Each KI Series detector Generator. constantly runs self-checks to provide important maintenance in- • KI-ABLT bases provide 520 Hz low frequency sounder formation.The results of the self-check are automatically updated capability to KI Series smoke and heat detectors,as well as and permanently stored in the detector's non-volatile memory. carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator.The KI-ABLT is suitable for ap- Automatic Device Mapping-The loop controller learns where plications requiring low frequency audible tones. each device's serial number address is installed relative to other devices on the circuit.The mapping feature provides supervision of each device's installed location to prevent a detector from being Warnings & Cautions reinstalled(after cleaning etc.)in a different location from where it g was originally. a This detector does not operate without electrical power.As Fast Stable Communication-On-board intelligence means less fires frequently cause power interruption, discuss further safe- information needs to be sent between the detector and the loop guards with the local fire protection specialist. controller.Other than regular supervisory polling response,the 0This detector does not sense fires in areas where heat cannot detector only needs to communicate with the loop controller when reach the detector. Heat from fires in walls, roofs,or on the it has something new to report. opposite side of closed doors may not reach the detector. • This heat detector by itself does not provide life safety protec- tion Use this detector with ionization and/or photoelectric smoke detectors. • This detector does not detect oxygen levels, smoke,toxic gases, or flames. Use this device as part of a broad-based life safety program which includes a variety of information sources pertaining to heat and smoke levels, extinguishment systems,visual and audible devices, and other safety mea- sures. • Independent studies indicate that heat detectors should only be used when property protection alone is involved. Never rely on heat detectors as the sole means of fire protection. Page 2 of 4 DATA 11 C L z- K65001-0647 Not tc be 4i4:i•ef i in zta'1P7�i>:, (3 Li r-3,:,.e s, issue i � Typical Wiring The detector mounting bases accept#18AWG(0,75MM2),#10 Relay Detector Base,KI-RB,KI-RB4 (J.Omm2). Normally-Normogy- #14AVYQ(1.5mm2). ond#12/WV��.5mm���naa�oo. Closed 01 on — #1O/AWG(1.0mm�and#18/�VG0.75mm�mepm�ned ��� --- includes' — - --`� 0orease of��e||��ion. ' ' ' - ration is selected during installation.The dry contact is Standard Detector Base,K;-SB'KI-SB4 rated for / amp(pilot duty) This io the basic mounting base Remote LED supervised to avoid accidentally for K]UUaK]Series detectors. LOU omJ-1 The GS/�LEDRemote LED iu aup ngay�pm odtoUonoat ��ww m���o Base. the oorkm|penoiThe m|aybase »=«*=~M Device Term Description Term Desorption L =c��� To'~~ does nc�ouppo�the GSA-LED 1 Normally Open Ramu{oLED. 4 DATA IN(-) (Pilot Duty) 4 DATA IN 4 Remote LED I(-) ~.. � .��� / 6 Not Used 6 Not Used 7 DATA OUT 7 DATA OUT DATA IN DATA From Signature ��� mw"mm�= or Previous Device Audible Sounder Bases,Fire Mode Isolator Detector Base,K|-|B,HJ-|134 ABDTABSTABLT sounder bases This base includes u built-in line fault isolator for use on Class A circuits.A detector must be installed for itto operate.The isolator base does not support the GSA-LED Remote LED. ~� x/*voT, 0 0 v/-Aocn The isolator m�ou� o�pmmu M�° ' �� mmacr o" " ~r/r "°""`m/uemeu�v�am�� Volume Setting Cut/remove Jumper for tato �==o" ���°oo �---~-' -~~'^~'''~`` Default at 10 msec intervals, Jumper for m^BST, beginning on one side 1. low dB Tone Setting of the Class A DATA IN I(-) S_ Sja 0AT—ATA. Default=Temporal DATA OUT IN INJOuT Cuttremove Jumper for circuit nearest the loop Steady controller,the isolators > id the nx�/ww o*�our�/ x�Aoor close to provide mw°muo,/"° Not Used ne�io�mtordown the p=me � Controller line with power or Previous--- Term Description whon�e���ornm� From m»«=* '"---� ' 24w*out to the short closes,it reopens within 1O °previous base ° ~ m next base oreoLrelay 4 Not Used maoo. 5 Not Used Data in Data out The pm000ampe�nbeginning on1he r°=mo�� ' � ' to next KI Series device other aideoftho|uopconind|o� ='=*" ^�" ~ �---~~ Page°",° DATA axcsr K85001-0647 i •• � Dimensions dde Technology that saves lives � �� \�s � I r i ,,�y/� � •j Contact us... Email: kidde.rire@fs.utc.com Web: kidde.com/engineeredsystems 1016 Corporate Park Drive Mebane,NC 27302 Kidde is a registered mark in the United States and other countries. 0 2018 Walter Kidde Portable Equipment. AlI rights reserved. Specifications K!-HRH Kf-t IFD Operating voltage _ 15.20 to 1.9.95 VDC 4 Normal operating current 51 pA Alarm current 68 NA Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Rate-of-rise rating 15°F/m_in(8°0/min) NA Fixed temperature rating 135°F(57.2°C).Actual alarm point 129 to 141°F(53.9 to 60.6°C). Maximum spacing 50 ft.(15.2 m)centers Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Testifire 2000 Operating environment 32 to 100°F(0 to 38°C),0 to 93%RH,non--condensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Agency Listings CAN/ULC-5530 UL 52i CAN/ULC-S530-M9i UL 521 Ordering Information Catalog ShipWt. Number Description Ibs(kg) K! HRD Intelligent fixed temperature/Rate-of-rise heat detector KI-HFD Intelligent fixed temperature heat detector 0.4(0'16) Gampatible Bases - Ki-SB Detector Mounting Base-Standard KI SB4 4-inch Detector Mounting Base c/w Trim Skirt KI-RB Detector Mounting Base w/Relay KI-RB4 4-inch Detector Mounting Base w/Relay, c/vv Trim Skirt 0.2(.09) KHB Detector Mounting Base w/Fault Isolator KI-I64 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt KI-ABST Audible(Sounder)Base for Fire Detectors KI-ABLT Low Frequency Audible(Sounder)Base forCO and Fire Detectors 0.3(0.15) DT ase for KI-AB Audible(Sounder)B CO and Fire Det_ectors GSA-LED Remote Alarm LED(not for EN54 applications) GSA-TS4 Trim Skirt(supplied with 4-inch bases) — GSA-TS Trim Skirt(optional for non 4-inch bases) 0.1 (0.04) S Page 4 of 4 D A'r A S H E=E T K85001-0647 °° m 4'0;to be..serf for itzstail:3t€or;perrpr,>t,s. Issue 1 idde fl Power Supplies and Accessories " K Technology that saves lives Sealed Lead -Acid Batteries u' lllll� � r i Overview Application Rechargeable sealed lead-acid batteries are ideal for use as a When multiple power supplies are provided,each power supply's secondary(standby)power source as defined by NFPA 72.Their battery requirements should be calculated individually. Consult low maintenance and high energy density make them ideal for fire the specific system manual to determine battery capacity require- alarm signaling applications. ments. Safety Information Standard Features Due to a battery's low internal resistance and high power density,high levels of short • Rechargeable circuit current can develop across battery terminals.Put on protective eye covering and remove all jewelry before working on batteries.Do not rest tools or cables on the • Non-spillable battery,and only use insulated tools.Follow all manufacturers installation instructions and diagrams when installing or maintaining batteries. • Non-hazardous • Low maintenance • High energy density Page 1 of 2 D A T A :3 1 1 L ET IK85010-0127 Not to a,od la ins.t.3aatian purposos Issue 1 Specifications Kidde __ _ - ( Case Material ABS Thermoplastic Regulatory Information DOT Class 60,Batteries,non-hazardous,non-spillable Operating Environment 32°F to 120°F(0°C to 49°C) 0 to 93%RH,Non-condensing _ Technology that saves lives Contact us... Ordering Information Email:kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSystems Catalog!Number Description Shipping Weight,lb(kg) 12V1 A2 1.2 Ah Sealed Lead Acid Battery-12 Vdc 1.25(0.57) Kidde is a UTC brand. 12V4A 4.5 Ah Sealed Lead Acid Battery-12 Vdc 5(2.27) 1016 Corporate Park Drive 12V6A5 7.2 Ah Sealed Lead Acid Battery-12 Vdc 6(2.72) Mebane,NC 27302 6V8A 8 Ah Sealed Lead Acid Battery-6 Vdc _4(1.81) 6V10A 12 Ah Sealed Lead Acid Battery-6 Vdc __ 5(2.27) ©201 s United Technologies Corporation. tt Acid B d A d L l 12V10A 11 Ah Sealed c 10 . 5 All rights reserved. Battery-12 Vdc 44 ( ) 12V17A 18 Ah Sealed Lead Acid Battery-12 Vdc 13(5.90) 12V24A 26 Ah Sealed Lead Acid Battery-12 Vdc 20(9.07) 12V40A 40 Ah Sealed Lead Acid Battery-12 Vdc 32(14.51) 12V50A 50 Ah Sealed Lead Acid Battery-12 Vdc 40(18.14) 12V65A 65 Ah Sealed Lead Acid Battery-12 Vdc 49(22.23) 0 Page 2 of 2 DAIA SHEET K85010-0127 m ru;t ir; br: ue,c:j p:vr,>nsas. Issue! Effective October 2016 Data TD450081ENDSIVI DSM Sync modules Description The DSM sync modules provide independent operation of synchronized temporal pattern (code 3) horn and synchronized strobe flash, as well as the ability to silence the horn while maintaining the strobe flash (audible silence)while using only a single pair of wires.The DSM-12/24 sync modules control either one(1)Class A or two (2) Class B NAC circuits.When using the low frequency 520 sounder(LFHSK)the DSM can provide the code three temporal (T3)and also the code four temporal (T4) for carbon monoxide notification. DSM Table 1. Products available for use with DSM sync module Model Description AH-WP,HS Audible horn MT with strobe(l) Multitone horn with sync strobes E and EH with strobe E and EH HIFI speakers with sync strobe ET70/90/1080 with strobe ET speakers with sync strobe RSS/RSSP strobes Remote sync strobes CH70 strobes D Chimes with sync strobes AS-WP,HS4 Audible horn with sync strobes LSPST,LHS LED speaker strobes and horn strobes LLFHSK Low frequency(520Hz)sounder strobes ,O Strobe portion of device is compatible;audible portion does not synchronize. F.T*N Powering Business Worldwide • Technical Data TD450081 EN Wheelock DSM Effective October 2016 Features & benefits Drawings • Uniquely designed to accept an independent strobe and audible input from the FACP and convert to a single output that connects to Wheelock compatible appliances. 4.97 1.34 • 3 ampere per circuit current handling at 12 or 24 VDC o 0@ • Low operating current draw • Compatible with all standard fire alarm control panels • Meets the NFPA-72 requirement for Temporal Pattern when 4.97 used with the Series AS/AH and/or Series Exceder Note: Please read these specifications and associated installation instructions before using,specifying,or installing this product. Visit Eaton.com/massnotification for current installation instructions. OO ® Qo Approvals & compliances Figure 1.DSM front and side views • Approvals include UL Standard 1971, ULC, New York City(MEA), California State Fire Marshal (CSFM) and Chicago(BFP) General information When calculating the total current, use Tables 1&2 to determine the highest value of"Rated Average Current" for the SM or DSM (across the listed voltage range), then add this value to the total current for any other appliances powered by the same source and include any required safety factors. Refer to Instruction Sheet for acidtional information. Table 2. Sync module(DSM) current requirements (AMPS) UL Voltage ULC Voltage Rated Average Current Rated Peak Current Rated Inrush Current In1/In2 Audible In1/In2 Audible In1/In2 Audible 8.0 VDC 10.5 VDC 0.019 0.004 0.055 0.004 0.150 0.016 12.0 VDC 12.0 VDC 0.020 0.004 0.064 0.004 0.170 0.019 24.0 VDC 24.0 VDC 0.035 0.008 0.080 0.008 0.342 0.030 33.0 VDC 33.0 VDC 0.045 0.010 0.090 0.010 0.470 0.040 8.0 VRMS 8.0 VRMS 0.028 0.005 0.107 0.008 0.210 0.016 12.0 VRMS 12.0 VRMS 0.030 0.006 0.103 0.009 0.240 0.019 24.0 VRMS 24.0 VRMS 0.048 0.010 0.145 0.015 0.480 0.033 33.0 VRMS 31.0 VRMS 0,062 0.012 0.175 0.022 0.685 0.056 Table 3. Current consumption DSM modules Output Circuit Description of DSM Module DSM Module Class"B"with Audible Silence (dual circuit) Y Class"B"with No Audible Silence (dual circuit) Y Class"A"with Audible Silence (single circuit) Y Class"A"with No Audible Silence (single circuit) Y Notes: 1. DSM dual sync modules are rated for 3.0 amperes per circuit.The maximum number of interconnected DSM modules is twenty(20). 2. Non-sync appliances can be installed before or after a DSM.If the non-sync appliance requires audible silence,four wire connection is necessary with the strobe circuit connected before the DSM NAC circuit,and the audible leads connected to a silenceable NAC circuit from the FACP 3. The audible appliance produces a momentary interruption(approximately 25ms)each time the strobes flash. 4. Circuit#2 may be omitted if only 1 circuit is required when using the DSM. 5. Non-sync audible appliances can be installed on the audible NAC. Be aware of the current requirement for the DSM module.See Table 2. 2 EATON www.eaton.com Wheelock DSM Technical Data TD450081 EN Effective October 2016 Table 4. Specifications and Ordering Information Model Number Finish Order Code Input Voltage VDC Average Current @ 12 or 24 VDC UIL Max 10 Mounting Options@ DSM-12/24-ROa e0 Red 6374 12 0.020 0.026 W 24 0.035 0.055 W O RMS current ratings are per UL average RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units).For strobes,the UL max current is usually at the minimum listed voltage(16v for 24v units).For audibles,the max current is usually at the maximum listed voltage(33v for 24v units).For unfiltered FWR ratings,see installation instructions. OO Refer to Data Sheet#TD45002BEN for mounting options. Oa The total distance from the first to the last DSM shall not exceed 1,000 feet of#18 AWG wire.Use only#18 AWG wire. Architects and engineers specifications The sync modules shall be Wheelock DSM sync modules.Wheelock DSM sync modules shall be the master controllers for Wheelock Execeder(HS),Wheelock Exceder LED (LSPST, LHS), and Wheelock AH-WP MT, E, EH, ET70/90/1080, RSS/RSSP and CH70 product lines appliances where a synchronized audible/visual audible or visual only appliance is specified.All modules shall be UL listed under Standard 464.Wheelock DSM modules shall be designed to interface with AS audible strobe appliances and horn strobe appliances to produce a synchronized temporal (Code 3)horn as well as synchronized strobe flash on a two-wire alarm circuit. DSM modules shall provide an additional strobe circuit input/output for control of either two Class "B" NAC circuits or a single Class "A" NAC circuit. Upon activation of the audible silence function at the fire alarm control panel,the audible signal component of AS audible strobes and/or NS horn stobes may be silenced while maintaining strobe activation. When using the low frequency 520 sounder(LFHSK)the DSM shall provide the code three temporal (T3)and also the code four temporal (T4)for carbon monoxide signalling. DSM module shall be DSM-12/24 for control of either Class A two(2) Class B NAC circuits.The DSM dual circuit version shall provide the additional capability of"daisy-chaining"—the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. Interconnection capability shall be for a maximum of 40 NAC circuits.All modules shall operate on either 12 or 24 VDC.The DSM 12/24 shall be 0.020 amperes @ 12 VDC and 0.035 amperes @ 24 VDC.The dual circuit DSM sync module shall be capable of handling a load of 3 amperes per NAC circuit at 12 or 24 VDC. All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of#18 to#12 AWG wire size. DSM sync modules shall mount to a 4-11/16" x 2-1/8" deep backbox. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Note:Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock, Inc. dba Eaton standard terms and conditions. Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 vvww.eaton.com/massnotification @ 2016 Eaton All Rights Reserved Eaton is a registered trademark. _ Printed in USA Publication No.TD450081 EN All other trademarks are property Powering Business Worldwide October 2016 of their respective owners. 1 . 14 1 Exceder LED3 Horn Strobes, Strobes & Horns Description The Wheelock ExcederTm LED3 horns, horn strobes,and strobes by a, Eaton feature an advanced power saving LED technology in a sleek, modern, enclosure that will provide high energy efficiency and an aesthetically pleasing low profile design that will blend with the building's interior decor. ( Compliant and Compatible Eaton's Exceder LED3 strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement,xenon and LED devices can now be in the • # `" same field of view.With the Exceder LED3 line, Eaton now offers 7> a full range of products with low and high candela settings ideal for both retrofits and new construction. ' High Efficiency, LED Technology Eaton's high energy efficient technology leads the industry in lowest current draw for the most popular candela settings,which reduces overall power consumption and costs in fire alarm and emergency communication systems.As the first notification appliances in the o industry to utilize LED as the light source,this breakthrough and patented optical design, resulting in best-in-class efficiency,enables material and system cost savings,allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies.All strobe models feature a wide-range of candela settings i (15,30, 75, 95cd)on a single appliance. _ Low Profile Design and Feature Set n7 r With the industry's smallest footprint,the Exceder LED3 horns, horn strobes, and strobes are aesthetically pleasing to building owners as the low profile design does not detract from the interior decor. Installers will benefit from its comprehensive feature list,including lowest current draw, no tools needed for setting changes, and convenient mounting options for both new and retrofit construction. These products are suitable for indoor ceiling-mount applications. The LSTC3 Strobe, LHSC3 Horn/Strobe, and the LHNC3 Horn are for 24V operation. LHNC3 is also suitable for 12V applications. Approvals and Synchronization The Exceder LED3 notification appliances are listed under UL Standards 1971 and 464 and under CAN/ULC-S525 and CAN/ULC- S526. The appliances are Restriction of Hazardous Substances (RoHS)compliant and contain no mercury or other hazardous substances. In addition,the Wheelock Exceder LED3 product line has been UL/ ULC listed as compatible with all Fire Alarm Control Panels(FACP) and accessories that have been determined to be compatible with Wheelock RSS strobe-based products including the RSS, CH, E, EH, ET,ST,, HS, MT,S8,SA,STH and Z Series. The listing also includes the ability to install the Exceder LED3 strobes in the same notification zone and field of view with any Wheelock RSS strobe FITO Nmodels. Powering Business Worldwide Technical Data TD450118EN Exceder LED3 Horn Strobes,Strobes&Horns Effective July 2017 Features Drawings • Energy Efficient • Patented LED provides industry's lowest current draw • Fewer power supplies required, smaller wire gauge, reduced wire runs o • Restriction of Hazardous Substances(RoHS) • Low-Profile Design • One of the smallest, most compact ceiling designs • Sleek, modern aesthetics with no visible mounting screws HORIZONTAL -x- • Special Lettering Available • 4 Field Selectable Settings in 1 Device • Select 15,30,75,95 cd 0 • 2 Audible Settings O 3.13 Select 90 or 95 dB • Select temporal or steady horn output • Easy-to-Install • Finger slide switches—No tools needed for setting changes • IN/OUT screw terminals using#12 to#18 3.13 AWG wires VERTICAL • Mounting Options include Exceder LSPKBB-C backboxes, -Y- 4" square, 1 1/2 or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep • Strobe Synchronization Components Figure 1.Ceiling Horn Strobe-Top View • Ability to mix xenon and LED strobes in the same field of view Meet synchronizing standards with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products • Compliance • NFPA 72 2016 -20 ms flash duration requirements • UL 1971, UL 464, ULC-S525, ULC-S526 • California State Fire Marshal (CSFM) • RoHS • FCC Part 15, ICES -x- Note:Please read these specifications and associated installation instruc- tions,before using,specifying,or installing this product.Visit Eaton.com/ massnotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range:' Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. 1.50 1.87 -Z- Figure 2.Ceiling Horn Strobe-Side View 2 EATON www.eaton.com a Exceder LED3 Horn Strobes,Strobes&Horns Technical Data TD450118EN Effective July 2017 Table 1. Strobe Ratings Table 2. Horn Ratings UUULC Max Current a Exceder LED3 Strobes 24VDC Exceder LED Horns Regulated Voltage Regulated Voltage Model Range VDC 15 30 75 95 Model Range VDC 95 dB 90 dB LSTC3 16.0-33.0 0.040 0.053 0.155 0.248 LHNC3 8.0-17.5 0.024 0.018 LHNC3 16.0-33.0 0.030 0.022 Table 3. Code 3 Horn Strobe Ratings UUULC Max Current a at Anechoic 95 dBA UUULC Max Current a at Anechoic 90 dBA Model Voltage b 15 30 75 95 Voltageb 15 30 75 95 LHSC3 16.0-33.0 0.044 0.061 0.169 0.267 16.0-33.0 0.042 0.060 0.168 0.264 Table 1. Table 4. Specification&Ordering Information Model Strobe Candela Red White LetteringSyheelonc w/ck Pow DSM e Wer Supplies Horn Strobes LHSRC3 15/30/75/95 X FIRE X LHSWC3 15/30/75/95 X FIRE X Strobes LSTRC3 15/30/75/95 X FIRE X LSTWC3 15/30/75/95 X FIRE X LSTRC3-AL 15/30/75/95 X ALERT X LSTWC3-AL 1 5/3 017 5/9 5 X ALERT X Horns LHNRC3 X No Lettering X LHNWC3 X No Lettering X Accessories LSPKBB-CR Exceder LED Backbox X LSPKBB-CW Exceder LED Backbox X Table 5. Specifications Physical Material Red or white textured UV stabilized,colored impregnated engineered plastic.Exceeds 94V-0 UL flammability rating Weight 0.55 lbs. Lens Light Emitting Diode(LED)in a rugged Lexan lens Dimensions 6.26"Diameter x 1.5"D Operating Temperature Indoor:32°F to 122°F(0°C to 50°C)and maximum humidity of 93% Mounting&Wire Connections Mounting(indoor only) Ceiling-mount applications.The LHNC3 can also be used for wall-mount applications.Exceder LSPKBB-C backboxes or to 4"square,1 1/2 or 2 1/8"and Octagonal,1%z"or 2 1/8"deep Wire Connections #12 through#18 AWG Power&General Operating voltage 12 VDCNFWR:8-17.5 VDCNFWR;24 VDCNFWR:16-33 VDCNFWR(12 VDC LHNC3 models only) Strobe Output Rating UL 1971,ULC S526:Selectable 15,30,75,95 candela output Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes and horns can be synchronized with Wheelock's DSM Sync Modules,PS Power Supplies or SAFEPATH prod- ucts,using Wheelock patented sync protocol Temporal Audible Pattern Selectable Continuous or Code 3 Horn tone:The Code 3 temporal pattern(1/2 second on,1/2 second off,1/2 second on, 1/2 second off,1/2 second on,1-1/2 off and repeat)is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. a RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units). For unfiltered FWR ratings,see installation instructions. b Regulated Voltage Range-VDC EATON www.eaton.com 3 ti a Technical Data TD450118EN Exceder LED3 Horn Strobes, Strobes&Horns Effective July 2017 Architects and Engineers Specifications The LHSC3 Audible Strobe, LSTC3 Strobe and LHNC3 mounting options shall include LED Ceiling backboxes,4" square, 1 1/2 The LED notification appliances shall be Wheelock®ExcederTm LED3 or 2 1/8"deep and 4" Octagonal, 1 t/2" or 2 1/8"deep. Two wire LHSC3 Audible Strobe appliances, LSTC3 Visual Strobe appliances appliance wiring shall be capable of directly connecting to the and LHNC3 Audible appliances for ceiling-mount applications with mounting base. Removal of an appliance shall result in a supervision a low-profile design or approved equals.The LHSC3 and LSTC3 fault condition by the Fire Alarm Control Panel(FACP). All Strobes shall be listed for UL Standard 1971 (Emergency Devices notification appliances shall be backwards compatible. for the Hearing-Impaired)for Indoor Fire Protection Service. The T LHSC3 and LHNC3 Audibles shall be UL Listed under Standard he LHSC3, LHNC3 and LSTC3 ceiling models shall have a low 464(Fire Protective Signaling). The Series shall be Restriction of profile measuring 6.26" Diameter with 1.5"D. Hazardous Substances(RoHS)compliant and contain no mercury or When synchronization is required,the appliance shall be compatible other hazardous substances.All Series shall meet the requirements with Wheelock®'s DSM Sync Modules, PS Power Supplies, of FCC Part 15 and ICES-003.All inputs shall be compatible with SAFEPATH products or other manufacturer's panels with built-in standard reverse polarity supervision of circuit wiring by a Fire Alarm Wheelock®Patented Sync Protocol.The strobes shall not drift out Control Panel (FACP)with the ability to operate from 16 to 33 VDC. of synchronization at any time during operation. If the sync protocol The LHSC3 Audible Strobe and LSTC3 Strobe appliances shall fails to operate,the strobe shall revert to a non-synchronized flash- produce a flash rate of one(1)flash per second over the Regulated rate and still maintain(1)flash per second over its Regulated Voltage Voltage Range and shall incorporate a Light Emitting Diode(LED)as Range.The appliance shall also be designed so that the audible the light source with a rugged Lexan®lens.The appliances shall be signal may be silenced while maintaining strobe activation when of low current design.The LED strobe flash duration shall be 20 ms. used with Wheelock®patented sync protocol. Where multi-candela appliances are specified,the strobe intensity shall have 4 field selectable settings at 15, 30,75, 95 candela for UL 1971, UL 464 ULC-S525-16, ULC-S526-16,CSFM, FCC, ICES, ceiling-mount applications.The selector switch for selecting the RoHS candela shall be tamper resistant. Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of two(2)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. r�a WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 Eaton.com/massnotification ©2017 Eaton All Rights Reserved Eaton is a registered trademark. _ Printed in USA Publication No.TD450118EN All other trademarks are property Powering Business Worldwide July 2017 of their respective owners. Technical Data TD450117EN Effective J u ly 2017 LHN3,LHS3,LST3 Exceder LED3 Horn Strobes, Strobes & Horns Description AThe Wheelock Exceder Tm LED3 horns, horn strobes,and strobes by Eaton feature an advanced power saving LED technology in a sleek, modern, single-gang enclosure that will provide high energy efficiency and an aesthetically pleasing low profile design that will blend with the building's interior d6cor. Compliant and Compatible Eaton's Exceder LED3 strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting IRE this latest requirement,xenon and LED devices can now be in the ' same field of view.With the Exceder LED3 line, Eaton now offers a full range of products with low and high candela settings ideal for both retrofits and new construction. High Efficiency, LED Technology Eaton's high energy efficient technology leads the industry in lowest current draw for the most popular candela settings,which reduces overall power consumption and costs in fire alarm and emergency V, communication systems.As the first notification appliances in the industry to utilize LED as the light source,this breakthrough and patented optical design, resulting in best-in-class efficiency,enables material ands stem cost savings,allowing fora greater number of appliances on the notification appliance circuit and fewer power supplies.All strobe models feature a wide-range of candela settings (15,30,75, 110cd)on a single appliance. Low Profile Design and Feature Set With the industry's smallest footprint,the Exceder LED3 horns, horn strobes,and strobes are aesthetically pleasing to building owners as the low profile design does not detract from the interior decor. Installers will benefit from its comprehensive feature list, including lowest current draw, single-gang design, no tools needed for setting changes,and three convenient mounting options for both new and retrofit construction.These products are suitable for indoor wall-mount applications.The LST3 Strobe, LHS3 Horn Strobe, and the LHN3 Horn are for 24V operation. LHN3 is suitable for 12V applications. Approvals and Synchronization The Exceder LED3 notification appliances are listed under U L Standards 1971 and 464 and under CAN/ULC-S525 and CAN/ULC- S526. The appliances are Restriction of Hazardous Substances (RoHS)compliant and contain no mercury or other hazardous substances. In addition,the Wheelock Exceder LED3 product line has been UU ULC listed as compatible with all Fire Alarm Control Panels(FACP) and accessories that have been determined to be compatible with Wheelock RSS strobe-based products including the RSS, CH, E, EH, ET,ST, HS, MT,S8,SA,STH and Z Series. The listing also includes the ability to install the Exceder LED3 strobes in the same EMTON notification zone and field of view with any Wheelock RSS strobe , models. Powering Business Worldwide y Technical Data TD450117EN Exceder LED3 Horn Strobes, Strobes & Horns Effective July 2017 Features Drawings • Energy Efficient • LED technology provides industry's lowest current draw • Fewer power supplies required,smaller wire gage,reduced wire runs 1.12 • Low-Profile Design • One of the smallest, most compact single-gang designs Sleek, modern aesthetics with no visible mounting screws • Special Lettering Available • 4 Field Selectable Settings in 1 Device 2.76 1.26 • Select 15,30, 75, 110 cd • 2 Audible Settings • Select 90 or 95 dB • Select temporal or steady horn output • Easy-to-Install • Finger slide switches—No tools needed for 4.53 setting changes • IN/OUT screw terminals using#12 to#18 AWG wires • Mounting Options include Exceder LSBB,any single-gang back- JL box and to 4" square with adapter kit ©oho ] • Strobe Synchronization Components • Meet synchronizing standards with Wheelock's DSM Sync Figure 1.Wall Strobe Modules, PS Power Supplies or SAFEPATH products • Ability to mix xenon and LED strobes in the same field of view • Compliance • NFPA 72 2016 -20 ms flash duration requirements • UL 1971, UL 464, ULC-S525, ULC-S526 1.12 • California State Fire Marshal(CSFM) • RoHS • FCC Part 15, ICES Note:Please read these specifications and associated installation instruc- 1.26 tions,before using,specifying,or installing this product.Visit Eaton.com/ 2•76 massnotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. 4.53 • All candela ratings represent minimum effective Strobe intensity based on UL 1971. Figure 2.Wall Hom Strobe 2 EATON www.eaton.com Y Exceder LED3 Horn Strobes, Strobes & Horns Technical Data TD450117EN Effective July 2017 Table 1. Strobe Ratings Table 2. Horn Ratings UUULC Max Current 1) Exceder LED3 Strobes 24VDC Exceder LED3 Horns Regulated Voltage Regulated Voltage Model Range VDC 15 30 75 110 Model Range VDC 95 dB 90 dB LST3 16.0-33.0 0.030 0.040 0.100 0.195 LHN3 8.0-17.5 0.024 0.018 LHN3 16.0-33.0 0.030 0.022 Table 3. Code 3 Horn Strobe Ratings UUULC Max Current(D at Anechoic 95 dBA UL/ULC Max Current 0 at Anechoic 90 dBA Model Voltage(2) 15 30 75 110 Voltage(D 15 30 75 110 LHS3 16.0-33.0 0.034 0.046 0.105 0.197 16.0-33.0 0.032 0.042 0.102 0.196 Table 4. Specification&Ordering Information Sync w/DSM or Model Order Code Strobe Candela Red White Lettering Wheelock Power Supplies Horn Strobes LHSR3 0526 15/30/75/110 X FIRE X LHSW3 0527 15/30/75/110 X FIRE X LHSR3-A 0740 15130/751110 X AGENT X LHSR3-N 0741 15/30/75/110 X No Lettering X LHSW3-A 0742 15/30/75/110 X AGENT X LHSW3-AL 0743 15/30/75/110 X ALERT X LHSW3-N 0744 15/30/75/110 X No Lettering X Strobes LSTR3 0528 15/30/75/110 X FIRE X LSTW3 0529 15/30/75/110 X FIRE X LSTR3-A 0747 15/30/75/110 X AGENT X LSTR3-AL 0748 15/30/75/110 X ALERT X LSTW3-A 0749 15/30/75/110 X AGENT X LSTW3-AL 0750 15/30/75/110 X ALERT X LSTW3-N 0751 15/30/75/110 X No Lettering X LSTR3-N 0754 15/30/75/110 X No Lettering X Horns LHNR3 0530 X X LHNW3 0531 X X Accessories LSBB-R 2420 Exceder LED Backbox X LSBB-W 2403 Exceder LED Backbox X ESB-KIT-R 0533 Exceder LED Trim Plate X ESB-KIT-W 0534 Exceder LED Trim Plate X Table 5. Specifications Physical Material Red or white textured UV stabilized,colored impregnated engineered plastic.Exceeds 94V-0 UL flammability rating Weight 0.35 lbs. Lens Light Emitting Diode(LED)in a rugged Lexan lens Dimensions 4.53"H x 2.76 W x 1.27"D; Trimplate:5.25"H x 4.58W x 0.32 D Operating Temperature Indoor:32°F to 122°F(0°C to 50°C)and maximum humidity of 93% Mounting&Wire Connections Mounting(indoor only) Wall-mount applications only.LHN3 can be used for wall and ceiling-mount applications. Single-gang,Exceder LSBB backboxes or to 4"square with adapter kit Wire Connections #12 through#18 AWG Power&General Operating voltage 12 VDCNFWR:8-17.5 VDCNFWR;24 VDCNFWR:16-33 VDCNFWR(12 VDC LHN3 models only) Strobe Output Rating UL 1971,ULC S526:Selectable 15,30,75,110 candela output Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules,PS Power Supplies or SAFEPATH products,using Wheelock patented sync protocol Temporal Audible Pattern Selectable Continuous or Code 3 Horn tone:The Code 3 temporal pattern(1/2 second on,1/2 second off,1/2 second on, 1/2 second off,1/2 second on,1-1/2 off and repeat)is specified by ANSI and NFPA 72 for standard emergency evacua- tion signaling. O RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units). For unfiltered FWR ratings,see installation instructions. (2)Regulated Voltage Range-VDC EATON www.eaton.com 3 Technical Data TD450117EN Exceder LED3 Horn Strobes, Strobes & Horns Effective July 2017 Architects and Engineers Specifications options shall include LED backboxes,single-gang backbox and to 4"square with adapter kit. Two wire appliance wiring shall be The LED notification appliances shall be Wheelock(D ExcederTm LED3 capable of directly connecting to the mounting base. Removal of LHS3 Audible Strobe appliances, LST3 Visual Strobe appliances and an appliance shall result in a supervision fault condition by the Fire LHN3 Audible appliances for wall-mount applications with a low- Alarm Control Panel(FRCP), All notification appliances shall be profile design or approved equals.The LHS3 and LST3 Strobes shall backwards compatible, be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired)for Indoor Fire Protection Service. The LHS3 and LHN3 The LHS3, LHN3 and LST3 wall models shall have a low profile Audibles shall be UL Listed under Standard 464(Fire Protective measuring 4.53"H x 2.76"W x 1.27"D. Signaling). All Series shall meet the requirements of FCC Part 15 When synchronization is required,the appliance shall be compatible and ICES-003.All inputs shall be compatible with standard reverse with Wheelock(D's DSM Sync Modules,PS Power Supplies, polarity supervision of circuit wiring by a Fire Alarm Control Panel SAFEPATH products or other manufacturer's panels with built-in (FACP)with the ability to operate from 16 to 33 VDC. Wheelock@ Patented Sync Protocol.The strobes shall not drift out The LHS3 Audible Strobe and LST3 Strobe appliances shall produce of synchronization at any time during operation. If the sync protocol a flash rate of one(1)flash per second over the Regulated Voltage fails to operate,the strobe shall revert to a non-synchronized flash- Range and shall incorporate a Light Emitting Diode(LED)as the rate and still maintain(1)flash per second over its Regulated Voltage light source with a rugged LexanO lens.The appliances shall be of Range.The appliance shall also be designed so that the audible low current design. The LED strobe flash duration shall be 20 ms. signal may be silenced while maintaining strobe activation when Where Multi-Candela appliances are specified,the strobe intensity used with Wheelock@ patented sync protocol. shall have 4 field selectable settings at 15,30,75, 110,candela for wall mount applications.The selector switch for selecting the NFPA 72 2016, UL 1971, UL 464 ULC-S525-16, ULC-S526-16, CSFM, candela shall be tamper resistant. Appliances with candela settings FCC, RoHS, ICES shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of two(2)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The LHS3 Audible Strobe, LST3 Strobe,and LHN3 Audible mounting Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. ArENSOMAMIS 11 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 Eaton.com/massnotification 9 2017 Eaton All Rights Reserved Printed! Eaton is a registered trademark. FM,,To N in USA Publication No.TD450117EN All other trademarks are prop rtye Powering Business Worldwide July 2017 of their respective owners, Riser Rat ® - . Conductors Bare Copper Insulation Polypropylene - ! Shielding N/A f + Jacket PVC 1 k j Listings FPLR/CL3R/FT4 Sunlight Resistant t ,g - ,i Voltage(max.) 300V Temperature(max.) 750 C r� 22 4 Solid Unshielded 18.00 18.8 0.123 12.5 4301 18 2 Solid ( Unshielded 6.52 22.8 0.138 14.7 4306 18 4 Solid Unshielded j 6.52 22.8 0.159 26.1 4307 18 6 Solid Unshielded j 6.52 22.8 0.190 40.0 4308 18 l 10 Solid ( Unshielded 6.52 22.8 0.244 63.2 4310 16 2 Solid Unshielded 4.10 22.3 0.165 22.5 4311 16 I 4 I Solid I Unshielded 4.10 22.3 0.201 40.2 4312 14 I 2 I Solid I Unshielded 2.57 24.1 0.192 ' 32.1 4313 14 4 j Solid Unshielded 2.57 24.1 0.225 60.7 4314 12 2 Solid I Unshielded ; 1.62 25.9 0.226 49.8 4315 12 2 65 Strand I Unshielded 1.65 24.9 0.264 53.8 4320 1 .k =i G�1;..=' ry.4.•:L.•.r p.',�;.i A "s�R 1 "aR 1 0 �' Y'^M� .1. 1 . ' ' ° 1• 040 11• 1 QAe 1 18 2 Solid Unshielded , 6.52 i 20.5 0.144 15.4 4431 16 2 Solid Unshielded 4.10 20.6 0.170 23.4 4432 •'r a„�t , LD� �7_G r ._ . . __ - --------- • DITEK DITEK's DTK-HW Series of surge protectors are designed and manufactured to meet the standards of the life safety industry. These compact, parallel-mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. ® �i ® TeGNA I.Specifip*atibins Part Number: DTK-120HW DTK-120/240HW i Service Voltage: — Single(2W+G), Split(3W+G), 120VAC 120/240VAC DTK-120HW MCO.V: 130V 130/260V Product Features } Protection Modes: L-G, L-N, N-G L-L, L-G, L-N, N-G ■Available for 120V and 120/240V systems i 700V L-N, L-G 700V L-N, L-G Y I Voltage Protection Rating: 600V N-G 600V N-G, 1200 L-L ■Approved for 20A circuit breakers — Surge Current Rating:, :` 18,000A 32,000A ■ Diagnostic LED indicates ground presence, i SCCR 10,000A system power and SPD function j■Weatherproof enclosure i Nominal Discharge 3kA 1,Current Rating ■ Small footprint enables installation in a variety of locations Mechanical Characteristics ■ Complies with ANSI/IEEE C62.41 and C62.45 Connection Method: a/4" NPT threaded fitting Category B standards Housing: I ABS Temperature Range: -40°F- 185°F(40-C-85°C) Maximum Humidity: 95% non-condensing Applications Dimensions: 2.83"L x 1.68"W x 2.93" H (71.9mm x 42.7mm x 74.4mm) ■ Equipment Panel Weight: 0.51b(227g) ■ Dedicated Branch Circuit Quality,Standards &Approval ------------------------------- Agency Approvals: UL1449, cUL Accessories SPD Type: ' .. SPD Type 2 ■ DIN Rail Mounting Kit—Part Number Standards Compliance IEEE Category B DTK-DRK ` Warranty: Ten Year Limited Every precaution has been taken to ensure that this literature is accurate and complete.DITEK corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information or for any errors or omissions. One DITEK Center 1720 Starkey Road-Largo,FL 33771 Doc.Number:SPS-100057-001 Rev 10 03/15 U MADE IN Phone:1-800-753-2345 Direct:727-812-5000 ©2015 DITEK Corp. 1MEE Technical Support:1-888-472-6100 Page 1 of 1 1 �' C LISTED I1S U. S. A. www.ditekcorp.com ti orb- � RICK SCOTT,GOVERNOR JONATHAN ZACHEM,SECRETARY Floridopr ab r,0 WEI . STATE OF FLORIDA DEPARTMENT OF BUSINESS_AN_D-PROFESSIONAL REGULATION ELECTRICALC�ONT_.RACTQ_RS�=LICE�-N-SING BOARD THE ALARM SYSTEM-.,CONTRACTOR I,,HE_RE1N IS G'ERTIFIED UNDER THE ' .� P,� �"..,d,+"-•- fir PROVISION Of';CHAPTER —,STATUTES _I „J ; J - I-- ti•; '-'A-_',lJ --_ 16 i �I. .iv �, -d`=-:.' r_ -_..�� !�y�� '7i . 'FLO R,I DA�F I.R_E S.E RV I,.E ,,I:N'C:.m: Iw'^(f '�14"C..� _' I'1 I'.h r,,.;�J_.. ;,f�•-� lv ' I' I= �:a:.,,a•��1+.--i'Y�'� �,� ..��-,,r�;V, �_�;� ;i�;ll;l2'$Q;1�E�AST•;>SR-6�01 __ --��,4, 33594-- ry''`= LI7CENSE>N.UMBER'-EF2000U81i1 EXPIRATION_:DATEAU�GUST 31, 2020 Always verify licenses online at MyFloridaLicense.com i i { Do not alter this document in any form. I . r This is your license. It is unlawful for anyone other than the licensee to use this document. ' 0 r: ,