Loading...
HomeMy WebLinkAbout20-22243 CITY OF ZEPHYRHI LS • 5335-8TH STREET (813)780-0020 22243 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:22243 Issued: 1/07/2020 Address: 3184 LYTTON HALL DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Towns ip: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 18,396.47 Subdi ision: HIDDEN RIVER Amount Paid: 18,396.47 Date Paid: 1/07/2020 Parcel umber: 24-26-21-0110-00000-3130 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Nam er LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Add re:e: s: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607-5995 Phone: (813)574-5743 Lic: Pho 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT APPLICATION FEES PLUMBING FEE 198.75 SEWER CONNECTION RESIDEW 2,090.00 ELECTRICAL FEE 298.13 WATER CONNECTION RESIDENT 1,010.00 MECHANICAL FEE 139.13 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 WATER METER RES 3/4" 473.78 PARK FEES SF 769.56 PUBLIC SAFETY 5% 26.35 BUILDING FEE 1,426.49 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 Inspections Req ire FOOTER 2ND ROUGH PLUMB Misc INSUIA ION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount o the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subs quent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be a ditional restrictions applicable to this property that may be found in the public records of this county, and there may be ad itional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of comme cement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Applicatio . All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFO E C.O. C NTRACTO IGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOU APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR OTICE REQUIRED PROTECT CARD FROM EATHER INSTR# 2020001691 BK 10033PG 2340 01/05/2020 03:14pm page 1 of 1 Rcpt: 2123080 Rec: 10.00 DS: 0.00 IT: 0.00 Nikki Alvarez—Sowles Esq. Pasco County Clerk $ Comptroller Permit No. Parcel ID N 24-26-21-0110-00000-3130 NOTICE OF COMMENC MENT State of 'Florida . . county of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE 2 PB 79 PGS 102-11 LOT 313 Street Address: 3184 Lytton Hall Drive Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Sci een Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address . City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5.. Surety: N/A Name Address City State Amount of Bond: $. Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lien is Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, P RT 1, SECTION 71.3.13, FLORIDA STATUTES; _AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR ROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPEC TION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President : - Signatory's Title/Office- The foregoing instrument was acknowledged before me this 15 day of November by Steve Robert Smith, - as Vice President (type o thority,e.g. er,trustee,attorney in fact)for Lennar Homes. LLC (n�rne,of,p6rty'o 'b -of whom instrumentwas executed). Personally Known 0 OR Produced Identification❑ NbtaryiSi�ure Type of Identification Produced Name.(Print) IS$a:Holleran: Verification pursuant to Section 92.525,Florida Statutes. Under penaltie �gjury,I d clare that I Have read the foregoing;arid that the facts stated in. it are true to the best of my knowledge and belief. �so � ELISSAM.HOLLERAN Signature of Natural Person Signing Above Gmmlealon FF 08583T o•,=Ex'Irea June Ii,2020 wpdata/bcs/bcsform: �F ' sondelThmTroyFolnlMunnce10D3i5701G STATE OF FLORIDA,COuNTV OF PASCO 41, THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE.DOCUMENT ON FILE OR OF PUBLIC RECORD:IN THIS OFFICE WITN SS MY HAND ANP OFFICIAL SEAL THIS Trust , 2 i J= DAY OF * = ,' (• ` y a ICY y kk*V N1KKI LVA LES.CLERK&COMPTROLLER DEPUTY CLERK ' � "` Xz . BY a�'j� ;' ,r1,� �RO/ C= F�� t f PAS CO COUNTY, FLORIDA Pnit No. ""Z `• `. `t DatePeOttitted Za ( \ Builder Name/Owner Name Control#' _ 6 County Pa{cel No. 2/—/q -2 l 0— d dtV-3/gSubDII iv::- n Address/Location ,o / Classificadonrrype of Uses v> Ce TRANSPORTATION IMPACT FEE " Rate: Sq.Ft Unit: 4 Z7A i Exempt ❑Yes ❑No How Determined ' Impact Fee Amount 3/ (� Zone No. TAZ: i ' I SCHOOLIMPACTFEE / Account (098) Sftle4a rilly Detached House Amount (057) Moblie.H ma. (058) Other Idential 123) Collectlor Fee Exempt U Yes ❑No How Determined PARKS AND,RECREATION EE Land Account Land Credit Lend Total iRecreation Account Recreation Credit .Recreation Total w Zone TOTAL AMOUNT $ Z�Cl Vr� • I Exempt ❑Yes No How Determined LIBRARY FEE Land Account Land Credit Land Total i Faclllty.Acoount Facility Credit Facility Total Exempt ❑Yee No How Determined Total Amount= i RESOURCE FEE ERU TOTALAMOUNT Prepared By Checked By NO CERTIFICATE O.00CUPANCY WILL BE ISSUEMOR FINAL INSPECTION PERFORM UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR B I ACENTRAL PERMITTING.OFFICEOF PASCO COUNTY Aclvmftdpement below doom ric Imply acceptance of concurrence,but elmply receipt ota copy of this forth,placing thabulftportriltowi r on nallci of thla assesemant and the cenditlonm of payment for mama. DATE RECEIVED BY RECEIPT NO. DATE BY 24-26-21-0110-00000-3130 1 Pasco County Property Appraisc r Page 1 of 1 Parcel ID 24-26-21-0110 00000-3130 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 nd $11,137 TAMPA , FL 33607-5995 Bu Iding $0 Extra Features $0 Physical Address 3184 LYTTON HALL DRIVE, Just Value $11,137 ZEPHYRHILLS, FL 33540 Assessed (Non- chool Amendment 1) $11,137 Legal Description (First 200 characters) HIDDEN RIVER PHASE 2 PB 79 PG Non-School Taxable Value $11,137 102 LOT 313 School Distri t Taxable Value $11,137 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 bf 1) _ Line'Use _Code IDescription 2oningunits Type 1Price Condition Value 1 1 0100V LP1-1 1 SFR MPUD 6,000.60 SF $4.50 0.40 $10,800 2] 0100V LP1-2 I SFR MPUD 937.00 SF $0.90 0.40 $337 _ A_ dditional L_a_nd_Infor ation Acres Tax Area FEMA Code l Res 1 ode Corn Code Condo Code 0.16 30ZH -- I HDRV HDRV HDRV Building Information (Crd: 1 of 1) Unimproved Parcel _ Extra Features (Card: of 1) Line -Code --DDescription !Year _ U_nits yV lua e _ No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC — ----- — Month/Year Book/Page --IT DO Code CC de Condition ,Amount _ 01/2019 98_54 / 3547 _ Warranty Deed 05 Vacant �$4,965,000_ 09/2011 8606 / 3376 _ I Warranty Deed 05 Vacant $0 06/2010 8360 / 1872 Certificate of Title ! 12 _ Vacant $0 _ 12/2005 6748 / 0894 Warranty Deed —� Vacant $0 12/2005` 6748 / 0891 Warranty Deed Vacant $0 12/2005 6748 / 0889 I Warranty Deed i Vacant $0 https:Hsearch.pascopa.com/parcel.aspx?parcel=2126240110000003130 1/6/2020 Lennar Homes-3184 Lytton Hall Dr:2,276 sqft Column SQ. FEET PRICE MAIN OR LIVING: 2,276 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,189.63 PARK IMPACT FEES $ 769.5E SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.2 TOTAL: $ 7,805.2 T I F'S:1 $ 3,632.0 99%1 $ 3,595.E 1% $ 36.3 TOTAL: $ 18,396.47 813 780-0020 City of Zephyrhills Permit A Dplication Fax-813-780-0021 Building Department Date Received DEC 10 2 e'' 813 363 __ 2891 Phone'' for Permitting V -r r l 1 —1— Owner's Name Lennar Homes,LLC Owi ier Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Ow ier Phone Number Fee Simple Titleholder Address I N/A JOB ADDRESS 3184 Lytton Hall Drive LOT# 0313 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-� 1-01-10-00000-3130 ,�� (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II./ p NEW CONSTR e ADD/ALT SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME = STEEL DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE ;U/R SF 2276 ::] SQ FOOTAGE 1817 HEIGHT 1 Story BUILDING $ �fj VALUATION OF TOTAL CO STRUCTION 0 AMP SERVICE ELECTRICAL $ l ® PROGRESS ENERGY Q W.R.E.C. PLUMBING $ 10 MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS FV71 ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES DO BUILDER COMPANY 11 ennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Address 4600 W. ress St.Ste. ,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY dmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipp oad, pa, FL 33613 License# I EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE F REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 530 Bayonet, F 4674-5308 License# I CFC042998 MECHANICAL COMPANY ayonet Plumbing, Heating &AC, Inc SIGNATURE xx REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, B net, F 34674-5308 License# CAC058062 OTHER COMPANY Sterling Quality Roofing, Inc SIGNATURE REGISTERED L_Y_L N J FEE CURREN Y/N Address 4211 Shoal Line B Spring Hill, FL 34607 License# 1 CCC057991 111111111111111111 11111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/lar a projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7 00) *" Agent(for the contractor)or Power of Attorney(for the owner)would be someone wil h notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/ ootage) Driveways-Not over Counter if on public roadways..needs ROW 9 NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 7, 3 OWNER OR AGENT CONTRACTOR Vw Subscribed and sworn*eallalaan rme s Subscribed ands n t a rmed)before me this o-rvov-I u by As 15-Nov-19 by Ashlee Callahan Who is/are personally known to me or Who is/are personally known to me or hasihave ffeduee as identification. as identification. Notary Public ry Public Commission No. FF985637 Commission No. FF985637 Elissa M.Holleran Elissa M.Holleran Name of Notary tvped,printed or stamped Name of Notary typed,printed or stamped RIlil4ltwll�AUIEAN EUMAN.MOld�'19AH , �G�mrr�t�ndp�0e��9J �i4rrffNft FPOmni i F1�k�duc��,xp�4 „ Briid3lu>aa�R+tat4rr�mc►►lar.71S1Gll � B�1d�in7,�F,J444#�ti�l�s'�M�lgll - OIL `m >) .! 4Fn J � ��f !rg ". ./��� ""4 �"-,'.'.'iLS�� r:_rr �^;i,�sr,: ,� �,Y..•4�rs:�-•. 4—,.=•i'� ;-='s?^ f I t 'G/ ��pFy '�� ^� '�r,ti•Y� iar:."'�•+W��^!1�hl i.��'f:Dl._....,+. i'•' wa,vo m. co OD I OD CD Ul � ` � .� f P @ •d i I r. Ct/ � ' l _ 1F— p a gff 00 . : + ., co p { ~ �` j���j ,� �, •{ t rttP P rd 2i �'y"`A i > co •�`"� -� �"'^-•.._,...-.,.., -.,,� .,.-,,�,�... -F^��....._,� »�q-�_�,•_.r,....,..�w-._.. '�"F�ti'� {..�y'� •.*'y' ,,.sit i cj fi Wes ' jf •d" k Y 5j� � ! d' " In CY) SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E. PL6T PaN NOT A BOUNDARY SURV LOT 313 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00*23'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND ON LOT AREA CALCULATIONS N NOTES TAKE PREFERENCE. LOT =--69-36-69 SQ. FT. ALL DATA SHOWN HEREON BASED ON THE LIVING AREA = 1838 S0. FT. ENTRY FT. ENGINEERING PLANS OF KIMLEY-HORN AND ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. GARAGE FT, II COVERED LANAI =--b!Z-A—SQ. FT. 10' PUBLIC UTILITY EASEMENT PATIO =23--SQ. FT. CONG. DRIVE =---119—SQ. FT. PRELIMINARY DRAWING: A/C & CONC PAD =--!—SQ. FT. THIS PLAN IS,FOR PERMITTING PURPOSES PRIVATE SIDEWALK =-?2--s0. FT. ONLY, NOT FOR CONSTRUCTION. VERIFY IMPERVIOUS ALL DIMENSIONS BEFORE ANY CONSTRUCTION. FT. T Soo FT. �PG(P) LEGEND: OFF LOT AREA CALCULATIONS --\w� = PROPOSED DRAINAGE FLOW (00.00) PROPOSED GRADE RIGHT OF WAY = N-- -3-06 SQ. FT. E-00.00 EXISTING GRADE DRIVE APRON =--L1L!--SQ. FT. PUBLIC SIDEWALK =--!-3R--SQ. FT. NOTES: SOD FT. LOT GRADING TYPE = A PROPOSED PAD ELEVATION TOTALS AREA =--16 FRONT SETBACK = 20'-29.75 SO. FT. SIDE SETBACK 10' DRIVEWAY =--i8-3SQ. FT. REAR SETBACK 10' SIDEWALK FT. Soo =--±415--SQ. FT. LOT 3 4 LAJ 2 0 S 81'27'46" E 1 f 10.001 .-j .. ........ LOT 287 ........... 2�. )4j .........0 .0 ..... 4L-ID) 2o, 0 P!Ww L0 w 0 20 1 76, C) C) __j Ln Ln 4- N\ 0 w 0 N W LOT 288 > 1O.C10, co LOT 312 rn m C4 LOT 289 -4 PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 72.75- GARAGE AREA: ELEVATIONS REFERENCED TO NATIONAL GEODETIC VERTICAL F- m DATUM OF 1929. MEAN SEA N DESCRIPTION: LEVEL= 00.00 FT. LL FMK7"Di ORD I BEARING I DELTA vi LOT 313, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", 6 2US ARC < co � .00, 1 95.34� 1 95.26; 1 N W27'3B- E 1 08!09'12" AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH 09 .00 67.85' 67.83 S 11*01'44" W 1 04'59'02"::� 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA 1 58.28' 1 58.26' 1 N 11*01'44 E > APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 9/26/2014 Square Feet: 6936.69 t LENNAR HOMES (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= <,CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC- CONCRETE, COV.= COVERED_E/P,=, ,EDGE OF PAVEMENT, ESM*T= EASEMENT, Qa F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND•IRON PIPE, FIR= FOUND IRON ROD,'F!I&D=-FOOND--NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCe=,PERIVANIENTIGONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2 IRON ROD & CAP No, 4493, a. " SN&,r)= SET NAIL-,& DISK No-.- 4493, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE ce > -- —Drmwn-gy:— JOHN R.BEACH&ASSOCIATES,INC. SIVIS SURVEYORS AND MAPPERS Checked By: t 911 WEST ST. PETERSBURG DRIVE JR8 ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1 =30 o NOT VALID WITHOUT ORIGINAL SIGNATURE Date; PLOT PLAN 12/3/19 ACS 4 • Jp� % SURVEYOR SEAL OF A FLORIDA LICENSED 1�i"NATU DATE AND MAPPER Revisions: FLORIDA-REG: LAND SURVEYOR No.'' LB#4493 JEFF M. EYE i6 ONAC'SURVEYOR,&''MAPPER No.7123 r Q� x I t Single Family Dwelling Plan Review Comments 1. F.F.E; shall be a minimum of 8" above the road elev tion and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F. C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit: All 4 sides f driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and mark at time of first inspection. 8: All A.D.A. requirements shall be met. - 9-. No electric,.plumbing;mechanical, or framing shall be.e covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical.damage unless protected by approved barriers. M303.4 of the F.B.C. 12. Water heaters shall comply with section P607.3 oft e E.B.C. 13. Foundation supports for A/C units shall be raised at east 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance withR308.4 of the F.B.C. 17. All means of egress are to be in accordance with R3 11 of the F.B.C. 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requimng an AFCI type breaker. 20. Carbon monoxide alarms will be required in new co istruction that uses fossil-burning heating or appliances or an attached garage. They shall be i stalled in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 40 .11 of the 2016 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least_ 10 feet around the structure. 25..R403.5.3Hot water pipe insulation Insulation for hot water'pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following:' Piping V/ inch (19.1 mm)and larger in nominal diameter. Piping serving more than_one dwelling unit. Piping located outside the conditioned space:_ Piping from the.water heater to a distribution manifold: Piping located under a floor slab. Buried in piping, Supply and return piping in recirculation systems other t an demand recirculation systems: 25. Blower door test shall be provided before C.O. 26.A copy 0 the enerpmeacls shall be with permit at all imes 27. Co&of cnal insulation re ort-shall be pr6vided with ermit before flnaL 28.No fence,Pool or screen enclosure .is issued with:thr ermit. F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 6ch Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) PASCO COUNTY Receipt Pate: 04/11/2016 BUILDING CON8TkUCT16M SeRVICtt Receipt Nufbbel: 1949113 P�CC .8731 Citizens Drive_ COUNTYFL.0RI0AY- Suite 230 OPEN SOAC65.VIBRAIVr-PLA 1 CES. NeW Plpil.R.Oey,FL 346,54 727-847-8126 NOT A PER IT Paid By Check# CC Auth# Cashier I'll Workstation Check 01408772 MLARNOID EfCCCP59W Fee Description Amount Paid Impact Fee k6il.derftlal Solid Waste Single FaMily, 49.14 TOW Payments: $49.14 Pavor Address Phone -TENNAR HOMES ,coirlmerits: 022248. 24-26-21-01-10r00090-3130 3184 LY.TTO NI HA4L QR- While you will bia,paying youf l6iliwith'Pasco,Coq ntV Building donstructibnServicPsithe full amount of credit card or e-c ieck fees,h&A 6w­ni abovei,lisioll..ted by'First, _ 611116j ppVffient seMcii. myroportslreportslIPASCOPRODIPASCOICustdmer-Reqeipt:vlf.rpt Print Date: 04/09/2020 p6g6 1 of 1