Loading...
HomeMy WebLinkAbout20-22252 CITY OF ZEPHYRHI LS 5335-8TH STREET (813)780-0020 22252 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION - Permit#:22252 Issued: 2/03/2020 Address: 7846 BROAD POINTE DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book Page: Cost: 226,539.15 Total Fees: 18,820.25 SubdiIvision: ZEPHYR LAKES Amount Paid: 18,820.25 Date Paid: 2/03/2020 Parcel Number: 35-25-21-0140-00800-0240 CONTRACTOR INFORMATION I OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TAMPA, FL 33637 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,011 SQ FT APPLICATION FEES- PLUMBING FEE 176.25 SEWER CONNECTION RE IDEW 2,090.00 ELECTRICAL FEE 264.38 WATER CONNECTION RESIDENI 1,010.00 MECHANICAL FEE 123.38 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,273.49 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 WATER METER RES 3/4" 473.78 PARK FEES SF 769.56 IRRIGATION CONNECTION 175.00 IRRIGATION METER 473.78 Inspections Required FOOTER 2ND ROUGH PLUMB MISC I INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER I MISC. ROUGH ELECTRIC LINTEL MISC I MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees wi I comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state a l encies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of ommencement." Complete Plans,Specifications and Must Accompany Applicat r n.All work shall be performed in accordance with City Codes and Ordinances. NO OCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. l l CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHO JT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOU NOTICE REQUIRED PROTECT CARD FROM WEATHER i PAS CO COUNTY, FLOWbA P�rr,Nt No. -2- <S Date Peonittad 7 ' Builder NamelOwner Nam Control IY' L7 dlOR,~ County PafSsl No. — 1 0�(J SubDiv: ! Addres9/Location F . ClasaMcationfTyps of U69 - i TRANSPORTATION IMPA FEE - Rate: sq.Ft UNL 2 Exempt ❑Yes ❑No How Determined kImpad Fee Amount 3 Zone No. TAM SCHOOLIMPACTFEE Account (068) SIng14arnily Detached House Amount S 7r g6S (067) Mobus Home (055) Other Idential 123) Coilectl n Fee ,. ` Exempt Yes ❑N How Determined PARKS MD RECREATION FEE Land Account Land Credit Land Total Recreallon Account Recreation Credit :Recreation Tottaal �y— Zone TOTAL AMOUNT Exempt ❑Yes ❑N How Determined LIBRARY FEE Land Account Land Credit Land Total Fadllty.Account Faculty Credit FacUly Total Exempt ❑Yes ❑ o How Determined Total Amount_ I RESOURCEFEE , ERU TOTAL AMOUNT Prepared By Chocked By NO cERfIFlCA!n.OF OCCUPANCY WILL BE ISSUED_OR FINAL INSPECTION PERFO WED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FO BY A CENTRAL PERMITTING OFFICEOF PASCO COUNTY AcunmMedpomontDotowdo n 1=11aeceytanrsorwn=eflMW&"!i cwptofacopyor,two(=.D�flp the bupdNp pamttt weer on nopce o106 aee®eament till Iha eondWons of payment for came. DATE RECEIVED BY RECEIPT NO. DATE BY " N INSTR#202001164440R BK 10044 PG 3919 Page 1 of 1 01/30/2020 10:52 A Ropt:2130558 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowl s,Esq.,Pasco County Clerk&Comptroller Permit No. Parcel ID No NOTICE OF COMMENCE7 MEN A State of Florida County of P2scalo THE UNDERSIGNED hereby gives notice that Improvement wlIj be made to certain real prope and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1 Description of Property: Parcel Identification No ni a4 (2ACC-k- Q!Q gg�ax-te-- -A4A QQ 4 Y3, Street Address: �1-%- 4u 7�0-cj -Pn-t rat- �V4-- ZeVnj'Wk;kk--" f L '3-5Zt+3 2. General Description of Improvement New Single-Family R s'deuce 3. Owner Information or Lessee information If the Lessee contracted for the improvement D.R.-HortQn. Inc Name 19AO2- TPIL--rnm Elrivp- 33037-- El Address city State Interest in Property: FQe5iMple Name of Fee Simple Titleholder. Address (V different from Owner listed above) city state 4. contractor. DR, HoftQn, I or, Name -12602 Telecom TAMnA FL Address Qm QdY-Q city state Contractor's Telephone No.: 5. surety: N/A Name Address city State Amount ofBond: N/A Telejhone No.: S. Lender. NZAA Name Address ZI—ty State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: David Glade Name 12.602 TolecQm Drive Ta�na 3 -E—L Address City State Telephone Number of Designated Parson: - 813-740-9720-- 8. In addition to himself,the owner designates NIA of to receive a copy of the Lienor's Notioa as provided in Section 713.13(1.)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner I - 9. Expiration date of Notice of Commencement(the expiration date may not be before t e completion of construction and trial payment to the contractor,but will,be one year from the date of recording unless a different date is sp 'led): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE IRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713 PART I ECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPS TY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR REC RDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury.I declare that I have read the foregoing notice commencern nt and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signature of Owner orLa ee,or0wrieft&'Lessee%Authorized Officer/Director/Pafter/M ager Assistant Sacr WD.R. Hatton, Inc Signatory's Title/Office The foregoing instrument was acknowledged before me this 3&4day of .-byl s Assistant Soneta (JD8 Of authority,e g.,officer,trustee,attorney in fart)for D.R.-H-arton, Inc (name of I arty on behalf of whom instrument was executed). Personally Known 5&OR Produced Identification C3 Notary Signature Type of Identification Produced Name(Print) DANA AN NE NAGWIN State of Florida Notary Public Commission GG 010661D fifes Jul 12.202D My Comm.EX e" wpdatalbmlnotloecommenement_pcOS3048 D.R.Horton-7846 Broad Point Dr.-2,011 sqft Column Es SQ. FEET PRICE MAIN OR LIVING: 2,011 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 226,539.15 FEE SHEET $ 1,175.00 ADDRESS $ 30.00 11 DRIVEWAY1 $ 45.00 BUILDING: $ 1,273.50 ELECTRICAL: $ 264.38 PLUMBING: $ 176.25 MECHANICAL: $ 123.38 SUB-TOTAL $ 1,837.50 TOTAL $ 1,837.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,964.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,171.47 D Q i i I o Single Family Dwelling Plan Review Com ents 1. F.F.E.. shall be a minimum of 8" above the road eleva ion and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F. .C. 3. Compaction test required if 24"or more of fill dirt is rought in at anyone place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides f driveway.thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked t time of first inspection. 8: A11 A.D.A."requirements shall be met: 9-. No electric,.plumbing; mechanical, or framing shall e:covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the ..B.C. (Fire Separation). 11. Appliances shall not be installed in a location where ub'bet to mechanical damage unless protected by approved barriers. M303.4 of the F:B. 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised_ at I ast 3" above finished grade. M130U 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance witli R308.4.of the F.B.C: 17. All means of egress are to be in accordance-with P,31 I of the F.B.C. 18. "Green.gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 10. Combination-type AFCI breakers are required at all ocations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new co struction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be sier arate from unit to unit. This includes all underground.plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant.Receptacles in accordance with 40 .11 of the 2016 N.E:C 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25. R403.5.3Hot Water.pipe insulation. Insulation for hot.water pipe with a minimum thermal resist- nob (R-value) of R-3 shall tie applied to the following: Piping 31, inch (1.9.1 mm) and larger in nominal diameter Piping serving more than:one dwelling unit: Piping located outside the conditioned space., Piping from the water heater to a distribution manifold:- Piping.located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other t an demand recirculation systems. 25. Blower door test shall be provided before C.O: 26. A co o the ener cacls shall be with Permit at all times. 27.. CoPV.o. MaUitsuladon report shall-be pt6vided witk Peimit be ore rinaL 28.No fence, pool or screen enclosure :is issued with A s-permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-N ational Electric Code (2016) Uity of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting I I I I I A I A All C_ hone Num er r , A a I A a a a I I A 1 9 Owner's Name Ow er P b Owner's Address Ow er Phone Number Fee Simple Titleholder Name Ow er Phone Number Fee Simple Titleholder Address JOB ADDRESS i 4-S4 �p 9 y-toLtA )01N,14c" SUBDIVISION ron ARCEL ID#13-q--7-S- o 1 OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR F7 ADD/ALT IGN DEMOLISH ff INSTALL F-] REPAIR PROPOSED USE 0 'SFR Q COMM THEIR TYPE OF CONSTRUCTION BLOCK = FRAME TEEL 'S U_ VZO J�_nrjgll 3 -3-o c DESCRIPTION OF WORK I BUILDING SIZE F _ S' Q FOOTAGE EIGHT . . . . . . . . . . . =BUILDING VALUATION OF TOTAL CON TRUCTION =ELECTRICAL AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING =MECHANICAL ' VALUATION OF MECHANICA INSTALLATION Z_o [ GAS 7� ROOFING SPECIALTY THER FINISHED FLOOR ELEVATIONS .q FLOOD ZONE AREA =YES NO %3 0 . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - - - - - - - - - - - - - - - - - - - - -BUILDER - - - - - - - - - - - - - - - - - - - - - - _3 COMPANY rJC SIGNATURE REGISTERED 11Y/ N 11 FEE CURREN I YIN Address alerpm-br License# I C_?,CO3 9 C),-2 ELECTRICIAN COMPANY 14mrin P.fec-Me SIGNATURE REGISTERED N- rEti CURREN Y/N Address Rio iq-,4aa VbA4 5&443 License# C, o 6 PLUMBER F COMPANY I P I um SIGNATURE REGISTERED JJY/ N FEEICURREN -YIN I Address lefon pw�, sb' (_ /0M k a ► License# MECHANICAL COMPANY R% SIGNATURE REGISTERED FEE CURREN Y I N Address (2,,,,6w -zum License# LCA Co 33 W�f OTHER COMPANY HC--b&-VQW ?64-112$ SIGNATURE REGISTERED Y�/ N FEE CURREN Y/N Address YS 3f-I—V Qeu 00+94-6- IN G License# 1 cc RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;�-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Conistruction Plans Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/largeprojects ", k , gy For---" su , COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(I;�.t f En ms R Permit for new construction. t Minimum ten(10)working days after submittal date. Required onsite,Con traction Plans,Stormwater Plans w/_Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All I ommercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with no,arized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Foots e) Driveways-Not over Counter if on public roadways..needs ROW NOTICE 0F DEED RESTRICTIONS: The undersigned understands that this permit may besubject to"deed"restriction which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors 'to undertake vvork. they nnoybe required bobe licensed in accordance vv|tbstate and local regu\a�ono. If the contractor in not licensed as.required by law, both the owner and contractor n?�y be cited for a misdemeanor violation under state kaw. If the owner or intended contractor are uncertain as to what licensing roquiremnnta may apply for the intended work/they are advised to contact the Pasco County Building inopeoUonDiviaion--'LicenolngiGen�onat727'847- 8008. Furthermore, if the owner has hired a contractor or contractora, he is, advised to have the contractor(s) sign portions of the "contractor B}od�' of this application for which they will be responsible. If you, as the owner sign as the contractor, that may ba an indication that ha |a not propady]icenoed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07. as amended. The undersigned also underetoDdo, that such feeo, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Feaa'and Resource Recovery Fmae must be paid prior to receiving e "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713. Florida Statutes, maanmendad): |f valuation of work is $2'5OO.0Oor more, | marUfv that 1' the app|\cont, have been provided with o copy of the "Florida Construction Linn Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and 'Oonaunner/�haire. If the applicant is someone othar than the"owner", | certify that | have obtained a copy of the above described document and pronn\aa in good faith to deliver itto the"owner"prior tucommencement, CO NTR&CTC}R`S/Ol0NER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has oornnnonoed prior to issuance of a permit and that all work will be performed to meet standards of all iovva regulating construction, County and City codes, zoning nagu|abnna. and land development regulations in the jurisdiction. \ also certify that | understand that the regulations of other government agencies may apply tothe intended work, 'and that it is my responsibility to identify what actions \ must take bube |ncompliance. Such agencies include but are not limited to: ' Department ofEnvironmental Protection-Cypress Beyhaada, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. ' Southwest Florida Water Management District-Wells, Cypress Bayheada, Wetland Areaa, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, VVastevvohar Treatment, Septic Tanks. ' US Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authorib^Runvv@ys. ( understand that the following restrictions apply to the use offill: ' - Use of fill |a not allowed in Flood Zone"\y' unless expressly permitted. - |f the fill nnaiehe\ is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "oo[npmnoating volume" will be submitted at time of permitting which is prepared by o professional engineer licensed by the State{fFlorida. - If the fill material is to be Used in Flood Zone "N' in noDOeobOO with o permitted building using stern vva|| construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area. ) certify that use of such fill will. not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent propartieu, the owner may be cited for violating the conditions ofthe building permit issued under the attached permit application, for lots \eoe than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. \ understand that.a separate permit may be required for electrical vvorh^ p|umbiOQ, signs, vve||o` pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical'codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the vvO[k authorized by such permit is commenced within-six months of permit iSouanoe, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be nequesbad, in writing, from the Building Official for a period not to exceed ninety (WO) days and will demonstrate justifiable o8u'se for the extension. If work ceases for ninety(90) consecutiVe days, the job is considered abandoned. . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TQ YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. I 1 OWNER Om AGENT OiEllomTa8cTO Subscribed and sworn to(or affiAped)bqfore me this Subscribed and sworn to(or affirmed)before me this Who is/are personally known to me or has/have produced Who is/are personally kno\hn to me or has/have produced as identification. as identification, ~ Notary Public NotaryPublic Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Notary Public-state of Florida 020 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 24, BLOCK 8, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. PC Line Table Una 8 Dfrectlon Length a y L1 N0034'52'E 40.00' 8 w3 �o n �I-Id I z �m: LOT 23 GRAPHIC SCALE to m co I BLOCK 8 I 0 15 30 S89'25'08'E „25.00'_ I S89'25 08 E 11 .68 of 3 5'D&AE cam—N o I - 33.3' 17.7'- Ld CL n- '.}� b I ,:: n r PROPOSED 5 'd•I N O �N Z 1504 ALLD( C. Nim �U> •;t.., �;•)>. ::-F�:;; 6.3' FINISHED FLOOR ,^o ..•: �IU dw C7 O F-gw a� I ]� ELEVATION- 90.4 a 6EL .0' O O m= cV O U �W :1'•_'e :Q',: o �J'm "a o �kJ 27.0• 70.0' •A/C M Of o mLnz I' I Dui 5' D&AE me �@ N89'25'08"W 11,C74' A N I . I I LOT 25 .. BLOCK 8 i I 1PI O 4 LOT CALCULATIONS LOT = 4,588 SQ. FT. LIVING AREA = 1,504 SQ. FT. GARAGE = 390 SQ. FT. ENTRY = 31 SQ. FT. LANAI = 86 SQ. FT. PATIO = 0 SQ. FT. DRIVEWAY = 432 SQ. FT. A/C PAD = 12 SQ. FT. WALKWAY = 61 SQ. FT. IMPERVIOU 3 = 55% = 2516 SQ. FT. SOD = 2,072 SQ. FT. OFF LOT CALCULATIONS PREPARED FOR: RIGHT OF AY = 480 SQ. FT. DRIVE AP ON = 133 SQ. FT. D!t HORN'N PUBLIC S = 200 SQ. FT. ft6d'ILR��� f SOD = 147 SQ. FT. TOTALS AREA = 5.068 SO. FT. BUILDING SETBACKS DRIVEWAY = 565 SQ. FT. FRONT: 20 SIDEWALK = 261 SQ. FT. GARAGE: 25' SOD = 2,219 SQ. FT. REAR: 15, SIDE: 5' SIDE STREET: 15' NOTES: LEGEND: 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — BUILDING SETBACK INE PI POINT OF INTERSECTION BASED ON THE APPROVED ENGINEERING PLANS PC POINT OF CURVATURE PREPARED BY HAMILTON ENGINEERING & — — — CENTERLINE PT POINT OF TANGENCY SURVEYING INC.. — --— RIGHT OF WAY UNE RP RADIUS POINT PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATI N PCP PERMANENT CONTROL POINT DATUM. TYP TYPICAL ==> PROPOSED DRAINAG FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES '� CONCRETE (P) PERcPLLAATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A UT PB) PLAT BOOK / AIR CONDITIONER THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/W SIDEWALK PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING SQ. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.I—M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM D&UE DRAINAGE&UTILITY EASEMENT. THIS IS NOT A SURVEY DE DRAINAGE EASEMENT(PUBLIC) UE THIS IS A PLOT PLAN ONLY D&AE DRAINAGE ACCESS EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED 09/26/2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE 'X", AREAS DETERMINED TO BE OF WAY, RESTRICTIONS OF RECORD WHICH OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. THE MAY AFFECT THE TITLE OR USE OF THE LAND. SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN INFORMATION. PLEASE CONTACT THE LOCAL F.E.M,A.AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. A5hR BEARING BASIS: 3. NOT VALID WITHOUT THE AUTHENTIC BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF BROAD ELECTRONIC SIGNATURE AND THE AUTHENTIC POINTE DRIVE BEING S00.34'52•W PER PLAT. A M E R I A N ELECTRONIC SEALND OF A FLORIDA LICENSED (FIELD DATE:) REVISED: SU FRVEY N CD �°=2' i Digitally signed by James W. SCALE: INC. a;;�:"V eo "I Boleman 1•= 30 FEET 8, MAPPING C .' %yy, l DN:cn=James W.Boleman, �•�`css+e .[? �p=Amedcan5uweying&Mapping, APPROVED BY: �B CERTIFICATION OF AUTHORIZATION UMBER LB#6393 a f to Inc.ou=HB, 3191 MAGUIRE BOULEVARD, SUITE 200 v �emall=JBolemanaasmcoporate.co FOR 190901 LOT 24, BLOCK 8 ''•�vnmcm®,A m,-u 1 Date:019.09241655:18-04'00' THE Joe No. ORLANDO, FLORIDA 3 03 �•�' �;' - FIRM DRAWN BY: DSB WWW.AMERICANSURVEYIINGAND APPING.COM JAMES W. BOLEMAN PSM# 6485 DATE PLOT PLAN 09-23-19�IA 1 t r T1 PASCO.COUNTY Receipt�pate: 04/11/2016 BUILDING CONSTRUCTION$ER GES Receipt.Number:. 1963223 8739 Citizens.Drive CouNW FLoAX suite`.230 pr ,.sBus.prBi Pucis„ New Port Richey,FL 34654 727'847rSi28 ** NOT A PER IT ** Paid By Check# CE Auth.#. Cashier ID Workstation Check ZH22252, RFIKAR- BCCC 35W c_k1107887 Fee.Deserinfion Atriotirit Paid Impact.Fee Residential Solid Waste Single Family 37.80 Total Payments: $37;80. pay or dress o e DRHi'DEANNE 1 02 TELECC?m DR TEMPLE`7ER'RACE.33637=0935 Cofrimentw 2ti 22252 7846 BROAD POINTE DR Whlle you.wili be paying your bill with Pasta County Bonding Construction SoNlmi the foil emouni of the didifcatd or e-ehec fees;NOT shown above,is cotlictid by F_irat" Billing Oyment services. myreports/reports/(PASCOPROD/PASCOICustomer Receipt Of rpt Print Date: 06l05/2020 Page 1 of 1