Loading...
HomeMy WebLinkAbout20-22373 I CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 22 73 ELECTRICAL PERMIT -PERMIT.INFORMATION .LOCATION"INFORMATION ' Permit#:22373 Issued: 1/28/2020 Address: 35958 SADDLE PALM WAY Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 37,940.00 Total Fees: 345.00 Subdivision: SILVERADO Amount Paid: 345.00 Date Paid: 1/28/2020 Parcel Number: 05-26-21-0080-00500-0040 CONTRACTOR.INFO.RMATION i' OWNER.INFORMATION Name: SOLAR BEAR LLC Name: DIETSCH, KEVIN Addr: 6101 JOHNS RD STE 8 Address: 35958 SADDLE PALM WAY TAMPA; FL 33634 ZEPHYRHILLS, FL 33541-2906 Phone: (727)218-9407 Lic: Phone: 612-244-8990 Work Desc: INSTALLATION ROOF MOUNT SOLAR PV SYSTEM APPLICATION FEES BUILDING FEE 345.00 SP C ION REQU(80 ROUGH ELECTRIC / CONSTRUCTION POLE /� 1 PRE-METER ( L� FINAL REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. C NTRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received r— 2,0 Phone Contact for Permitting 727 940.3256 Owner's Name DIETSCH KEVIN Owner Phone Number 6122448990 5958 SADDLE PALM WAY,ZEPHYRHILLS,FL 3354 Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 35958 SADDLE PALM WAY,ZEPHYRHILLS,FL 33541 LOT# 4� SUBDIVISION SILVERADO RANCH PARCEL ID#1 05-26-21-0080-00500-0040 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT 0 SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 11.7KW BUILDING SIZE SQ FOOTAGE HEIGHT BUILDING $ VALUATION OF TOTAL CONSTRUCTION X=ELECTRICAL $ 37,940 AMP SERVICE = PROGRESSSS)ENERGY�j= W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREN Address License# OLAR BE ELECTRICIAN �Afl '/�'q J COMPANY SAR LLC SIGNATURE I J , REGISTERED JWN FEE CURREN Y/N Address 6101 JOHNS RD STE B TAMPA FL 33634 License# CC13009020 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# Illltlltlllllllllllllllllllllllllllllllllllllllllllltllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonmwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionstlarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions:• Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) '• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PloVSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) ^ OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and swo %o_r affr "ed re, e t by by— �V — o_ Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced DL as identification. DL as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Sh��t,Y'� &,- Date Received: /- 13-2,W Site: -3 5clUb T,-ddf.- All,,Gl , Permit Type: Approved w/no,comments Approved w/the below comments: 0 Denied w/the below comments: This comment sheet shall be kept with the permit and/or plans. In/I- JAN 2 3 ?020 KaIV�—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#2019212769 OR BK 10022 PG 3451 Page 1 of 1 12/16/2019 11:36 AM Rcpt:2117521 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller PREPARED BY:SOLAR BEAR LLC 6101 JOHNS RD STE B TAMPA FL 33634 Permit Number Parcel ID Number 05-26-21-000eo-66500-o0a6 -•_ -- ___ NOTICE OF COMMENCEMENT State of Florlda County of PASCO THE UNDERSIGNED hereby gives notice that Improvements MR be made to certain real property,and In accordance with Section 713.13 of the Florida Statutes,the following Information Is provided In this NOTICE OF COMMENCEMENT. SILVERADO RANCH SUBDIVISION PHASES 6,8 8 9A PB 75 PG 075 BLOCK 5 LOT 4 1.Desciipttonoiprnperty(legaldescriptfon): a)Street Uob)Address: ?,5 qwS Saddle 2.Geneml description of Improvements: INSTALL SOLAR PV SYSTEM 3.Owner Information or Lessee Information it the Lessee contracted for the improvement: — a)Name and address Ut sc - '----*_(�ddge_Vdt>7 2- b)Name and address of lee simple thleholder(Ilddterent than Owner listed above) c)Interest In property. 10D% _ 4.Contractor information a)Name and address: NORMAN PURKEY-SOLAR BEAR LLC-6101 JOHNS RD STE B TAMPA FL33634 _ b)Telephone No.: 727.940.3256 Fax No.:(optional) WA S.Surety(if applicable,a copy of the payment bond Is anached) a)Name and address: N/A h)Telephone No.: ------- - -_----------- .—_._.._—�T—_.__ c)Amount of Bond: 3 6.Lender a)Name and address: N/A _ b)Telephone No.: _ 7.Persons within the State of Florida designated byOwner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7,Florida Statutes: a)Name and address WA b)Telephone No- Fax No.:(oplIonaq Wn addition to himself or herself,Owner designates wA _ _ _ of to receive a copy of the Llenots Notice as provided In Section 713.13 0)(b),Fla^!da StalNes. b)Phone Number 01 Person or entity designated by Owner: 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and gnat payment to the contractor,but will be 1 year Dom the date of recording unless a different date Is specitiedL_ 20 I WARNING TO OWNER:ANY PAYMENTS MADE BY THE OYYNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE': • CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR I PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION"IF YOU INTEND TO OBTAIN FINANCING,CONSULT_ WITH YOUR LENDER OR AN 1 ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. i Under penalty at per[ury,I declare that I have read the foregalag notice of commencement and that The facts stated therein are true to the best of my knowledge an - `1 �_kE J 1� ET SC a1 ena o1�sYlteralessee,a0wnerslHLessee's(llaaoke000e1eDrectaNPaMetlMameer) tNam am FmAdeslinaw"TMelintee) the fore oing Instru�meatwas acknowledged before me INS day of 7 9'em k/ .20Ig by —LAe"-n :ef5(,k _ as ---- (hPeate01fte.g.ateeer,eumee.aromrylnbey fair as (Name or Penan) pypa ornulAarxy�.e.p.oFimr,Inrsten,�etrneYrn teW for (name al parry on beball of whom Instwem was executed). Personally Krim ❑ Produced ID [] Type of IDS.D Notary SI9nawre-_—r, 10MERAI MJJUN Print name —5 dhlm; alp " f( MYCOMMISSIONflG0314314 EXPIRES:Minch 19,2023 I__ •• aarlr�lTMulietaiyPa5Ve UrdewA4n ._. ___ I DocuSign Envelope ID:49B21377-74504C33-A067-DA85EF3AFE8C SOLARR—L EEf,E,ENE,ES SOLAR BEAR LLC 6101 Johns Road,Suite 8,Tampa,FL 33634 Your Solar Solutions Provider (727)471-7442 WW W.OURSOLARBEAR.COM EC13009020 SOLAR HOME IMPROVEMENT AGREEMENT DATE: CUSTOMER NAME(hereinafter,the"Customer") 12/2/2019 Kevin & Frances Dietsch ADDRESS: 35958 saddle-Palm Way CITY,STATE,ZIP: ' zephyrhills, FL 33541 HOME PHONE NUMBER: WORK PHONE NUMBER: MOBILE PHONE NUMBER: 612-244-8990 612-401-9161 - EMAIL: dietsch.kevin@gmail .com This Solar Home Improvement Agreement(this"Agreement")is between Solar Bear LLC("Solar Bear","we"or"Contractor")and you("Customer")for the sale and installation of the solar system described below(the"Project"or the"System")at your home (the"Property"or your"Home").The Parties agree as follows: 1.Was a full years usage of the customers electric bills provided? YES F-1 NO Fx 2. If no, does the customer understand we can not guarantee a 95%-105% of the previous YES El NO a years usage. 3. Does the customer understand the 26% TAX CREDIT is based on their taxable income? YES r x NO F� IF YOU DO NOT PAY INCOME TAXES YOU DO NOT GET A TAX CREDIT PROPOSED SYSTEM SIZE PURCHASED SYSTEM SIZE (Based on 12 months previous usage) 11.7 KW 18,076 KWH ANNUALLY 11.7 KW 18,076 KWH ANNUALLY CONTRACT PRICE AND TERMS OF PAYMENTS. I understand,that if I cancel, I will be held financially responsible for the cost of the permit and any work that 37,940 may J y have taken 8A Total System Cost: � rled by: F] Check Here If Any Portion of the project Sign' Total System Cost is Financed. 12/2/2019 If checked,the Customer will receive a separate Date agreement from the Finance Provider outlying their terms and conditions. AMOUNT PAID TODAY: $ 0 BALANCE REMAINING: $ 37,440 eg *An explanation of the Recommended System Size has been explained to me and I have a copy*An explanation of the Federal Investment Tax Credit(ITC) has been explained to me and I have a copy INITIAL NOTICE OF RIGHTTO CANCEL THIS IS A LEGAL BINDING AGREEMENT AND YOU MAY ONLY CANCEL THIS AGREEMENT PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS AGREEMENT.TO CANCEL THIS AGREEMENT,PLEASE SEETHE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT.THANK YOU FOR YOUR ALLOWING US TO SERVE YOU 12/2/2019 Customer Signature: Dids Date: Customer Signature: Date: roe�s,onea er. 12/2/2019 Representative: I .w6w ber6ws0 Date: ]amCL9lGfGi6i... I F '`o s '�f''.F3 i �/` + w�++ ,• ,Iqq+ftj�.iµ,*� ,ty' •' • . F.�k 2'!a i'xf'�'S't' j } !.' '• �,�ec i.•y�^'ll,ki',¢ ar y y y .•�^ � _ r. �#�,, r ,� •M Rio' i I� f . , ,," ,,f• fie. •! !+ t �2r it 't ts* * '''.-i' � *���• w,;'�i�r',r #* ' r'- » ,�`tl K ,a `.� ,+f�f"-'� �* i r �4*4,� f+�• � � '�'i �+f',y����"' t '�1 +�+�ytx ' t :�'{. y . ,,yfl�3�d�j��r• kit �i"• •'�' +'gyp*. • �7r. } " + _ i INL!kr` r + IN it 16 • !< " is r ^l t t ry t r 1• xn R 4q . - g '�+ �min � Y �• r� �,. �33ex`.�� - .�- �, �*` �• ��,��� }��.. �tom.'. y ^r ;s • i ter, • #^ Site Assessment Customer: KEVIN DIETSCH Address: 35958 Saddle Palm Way Zephyrhills,FL 33541 Component List Manufacturer Model Quantity Silfab Solar SLA300M 39 SolarEdge Technologies Inc. P320 39 SolarEdge Technologies Inc. SE10000H-US 1 8031fzfSf1:9 ft L6 r- r O � 61, (] - ' c O C) F-� R O� AC PIMPSPIPRIN CO Pq LROdIdO =WW""dald Ww"IdidtdIdbd � _ _ � Notes: powered by aurora 5 6 7 8 9 I 2 3 4 GENERAL MAKE SOLAREDGE MAKE 1.1. CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH NEC 2014 AND FBC 2017 REQUIREMENTS AND EQUIPMENT INSTALLATION INSTRUCTIONS MODEL MODEL NOT SPECIFIED IN THIS PLAN. 1.2. CONDUCTOR TYPES SHALL MEET THE REQUIREMENTS SET FOURTH IN NEC 310.10 BASED ON INSTALLATION LOCATION. INPUT POWER 320 W RATED POWER W 1.3. DIRECT-CURRENT PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS INSIDE A BUILDING SHALL BE CONTAINED IN METAL RACEWAYS 690.31(G). MAX INPUT VOLTAGE 48 V VMPP V 1.4. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). I.S. CONDUCTOR SIZING IS BASED ON RACEWAYS NOT EXPOSED TO DIRECT SUNLIGHT UNLESS STATED OTHERWISE. 10%OF CIRCUIT LENGTH CAN MAX INPUT CURRENT 13.75 A IMPP A BE EXPOSED DIRECT SUNLIGHT UP TO 10FT,NEC 310.15(A)(2). MAX OUTPUT CURRENT 15 A VOC V 1.6. PV SOURCE AND OUTPUT CIRCUIT CONDUCTORS ARE SIZED BE EXPOSED TO DIRECT SUNLIGHT GREATER THAN 10%OF THEIR LENGTH WHEN A INSTALLED IN RACEWAYS W OR GREATER ABOVE ROOF.ADJUSTMENTS ARE BASED ON MAX STRING CURRENT OF 15A,35C AMBIENT MAX STRING POWER 6000 W ISC TEMPERATURE,NEC 310.15(B)(2XA)AND 310.15(BX3)(C). (� OPTIMIZER RATINGS �( 1 MODULE_RATINGS SYSTEM SPECIFIC 2.1. THE OUTPUT VOLTAGE OF THE OPTIMIZERS ARE REGULATED BY THE INVERTER AND ARE NOT IMPACTED BY THE NUMBER OF MODULES IN THE I"` STRING.THE CONTINUOUS CURRENT OF A SINGLE STRING IS EQUAL TO THE MAXIMUM OUTPUT CURRENT OF THE OPTIMIZER OF 15A. MAKE tv #MODS 2.2. THE INVERTER IS EQUIPPED WITH A RAPID SHUTDOWN FEATURE WHICH CONFORMS TO NEC 690.12(2014). #INVERTERS 2.3. THE INVERTER IS NON-ISOLATED AND UNGROUNDED.NEITHER THE NEGATIVE NOR POSITIVE CONDUCTOR IS GROUNDED AND HAS A COMMON MODEL AC AND DC EQUIPMENT GROUNDING TERMINAL THEREFORE NO DC GEC IS REQUIRED. MAX INPUT POWER t48000 #STRINGSIINV 3 2.4. UTILITY CONNECTION SHALL Be MADE AS SHOWN BY LINE-SIDE-TAP PER ARTICLE 705.12(A)USING INSULATED,PIERCING CONNECTORS UL MAX INPUT VOLTAGE MIN STRING SIZE 8 MOD LISTED FOR THIS PURPOSE AND LOCATED WITHIN CODE COMPLIANT ENCLOSURE. 2.5. INTEGRATED DC DISCONNECT IS PROVIDED WITH INVERTER. NOM INPUT VOLTAGE 400 V MAX STRING SIZE 18 MOD GROINIDING MAX INPUT CURRENT 30.5 A STC DC RATING 11.47 KW 3.1. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250&690. 3.2. PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED NOM AC VOLTAGE 240 V AC OUTPUT RATING 11.4 KW BY LOCAL JURISDICTION.EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE NTH NEC 250.120(C). 01 % 3.3. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF#10 AWG WHEN NOT MAX AC CURRENT 47.5 A DC/AC 21 1 t68 A EXPOSED TO DAMAGE,AND#6 AWI3 SHALL BE USED WHEN EXPOSED TO DAMAGE. NOM AC POWER 11400 W MPP CURRENT 01 GENERAL NOTES I INVERTER RATINGS n SYSTEM ID RUN VOLTAGE(V) CURRENT(A) VD(%) LENGTH CONDUCTOR SIZE Ql/KFT CONDUIT SIZE #CCC EGC OCPD TERM(C) TEMP ADJ FILL ADJ BASE AMP DERATED AMP A STR-JBOX 400 13.95 1 116 PV WIRE #10 1.24 FREE AIR NA 6 #10 NA 75 0.96 1 35 35 THHN/THWN-2 1 PV WIRE #10 1.24 PVC/EMT/FMC 6 #10 NA 75 0.96 0.8 35 30.72 8 JBOX-!NV 400 13.95 1 116 C INV-DISC 240 47.5 1 51 THHN/THWN-2 #6 0.491 PVC/EMT/FMC/NMLT 3 #10 60 75 0.96 1 65 65 D DISC-PCC 240 47.5 1 51 THHN/THWN-2 #6 0.491 PVC/EMT/FMC/NMLT 3 #10 60 75 0.96 1 65 65 cEs BASED ON MAX CONOrnONS. IRCUIT LENGTH BASED ON 1%VOLTAGE DROP.SEE NOTE 1.6 FOR RACEWAYS IN DIRECT SUNLIGHT."CCC:CURRENT CARRYING CONDUCTORS CONDUCTOR SCHEDULE M �-1 JBOX RE:NOTE 2.4 01 e o e 08-1 INVERTER/ D EXISTING 200A B EV CHARGER 120/240V MAIN 08-18 MODS _ 1 08-18 MODS - 200 SE P320 08-18 MODS ti 1 PH LOCKABLE FUSED AC E A:#10 PV WIRE, DISCONNECT,120/240V, 600V RATED ALL WOR L * �� MIN 60A,W/60A FUSES EGC Bp IDA BUILDING CODE, NEC 230.79 ' ' " COD tlz; • AT ROOF ARRAY EL► �+1 RIC E, EXISTING SYSTEM,NdOOM≥w CITY OF ZEPHYRHILLS �r `` � ZO�a .� ^�`�'y '" O E'� "� GROUNDING C�RDINNVCE8 REVIEW DAT F '� ' Q - ELECTRODE CITY OF ZEPHYRHI *` 8l25D ELECTRICAL LINE DIAGRAM PLAN EXAMINER O2 * * CONTRACTOR EC13009020 C�Eb BY VER DESCRIPTION .O UNAUTHORIZED USE OF THIS G F DRAWING SET WITHOUT #'. 07.2 D 01 INITIAL DESIGN KEVIN DIETSCH SOLAR BEAR LLC b WRITTEN PERMISSION FRO ' .•f l PAPER: 6101 JOHNS RD STE#8,TAMPA CONTRACTOR IS IN VIOLAT �� `,��' ARCHB 35958 SADDLE PALM WAY,ZEPHYRHILLS FL 33541 FL 33634 OF U.S.COPYRIGHT LAWS AND I£. PH:813-535-6627 WILL BE SUBJECT TO CIVIL SPENCER A.ROBINSON SCALE: DAMAGES AND PROSECUTIONS. PE81250 NTS PROJECT ID: 0107205E11.47-LAPS VWVW.OURSOLARBEAR.COM 1 2 I 3 I 4 I 5 I 6 I 7 8 I 9 PHOTOVOLTAIC DISCONNECT LOCATION:EACH INVERTER&BATTERY,NEC 690.5(C) LOCATION:EACH DISCONNECT,NEC 690.13(B),NFPA 11.12 LOCATION:DC DISCONNECT,NEC 690.17 MPP CURRENT 28.68 A PHOTOVOLTAIC AC DISCONNECT MPP VOLTAGE 400 V AC OUTPUT VOLTAGE 240 V B MAX VOLTAGE 480 V AC OUTPUT CURRENT 47.5 A MAX CURRENT 45 A LOCATION:AC DISCONNECT,NEC 690.54 LOCATION: DC DISCONNECT, NEC 690.53 LOCATION:JBOX,COMBINER BOX,DC DISCONNECT,NEC 690.35(F) LOC:MARKINGS SHALL COMPLY WITH NEC 690.31(E)(3),690.31(E)(4) LOCATION:MAIN SERVICE DISCONNECT,NFPA 11.12 AND NFPA 11.12 AND SHALL BE PLACED ON ALL INTERIOR AND LOCATION:RAPID SHUTDOWN SWITCH,NEC 690.56(C) EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES,AND CABLE ASSEMBLIES AT LEAST EVERY 10 FEET;AT TURNS AND SOLAR SYSTEM POWERED BY ABOVE/BELOW PENETRATIONS AND ALL JUNCTION BOXES. SOLAR BEAR LLC WARNING: DUAL POWER PH:813-535-6627 SOURCES. SECOND SOURCE V*WW.OURSOLARBEAR.COM IS PV SYSTEM LOCATION:ADJACENT TO MAIN SERVICE DISC, NFPA 11.12 LOCATION:POINT OF INTERCONNECTION,NEC 705.12(0X3) GENERAL 1.1. LABELING REQUIREMENTS BASED ON NEC 2014&NFPA 2015. 1.2. MATERIALS USED ARE SUBJECT TO THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3. LABEL MATERIALS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE E ENVIRONMENT. 1.4. LABELS SHALL BE A MINIMUM LETTER HEIGHT OF 3/8"AND PERMANENTLY AFFIXED. LABELS �• �. •�-��` • No 81280 - = CONTRACTOR EC13009020 UNAUTHORIZED USE OF THIS N R R ' DATE BY VER DESCRIPTION F KEVIN DIETSCH SOLAR BEAR LLC DRAWING SET WITHOUT O1.07.21 A.D 01 INITIAL DESIGN L•O 1 � 6101 JOHNS RD STE#8, TAMPA WRITTEN PERMISSION FR • �� ��,' PAPER: 35958 SADDLE PALM WAY,ZEPHYRHILLS FL 33541 FL 33634 CONTRACTOR IS IN VIO O r ____ = ______________________________ ARCHB OF U.S.COPYRIGHT LA D �� 1 PH:813-535-6627 WILL BE SUBJECT TO CIVIL SPENCER A.ROBINSON SCALE: PROJECT ID: 010720SE11.47-BAPS VWVW.OURSOLARBEAR.COM DAMAGES AND PROSECUTIONS. PE81250 = ________________________________ NTS I I 2 I 3 I 4 I 5 I 6 I 7 I 8 I 9 / EV Charging Single Phase Inverter / EV Charging Single Phase Inverter for North America g for North America SE38WH-US/SES=H-US J SE6000H-US/SE7600H-US/SE11400H-US SE3800H-US/SES000H-US/SE6000H-US/SE7600H-US/SE11400H-US EV CHARGER AND EV CHARGER CABLE SPECIFICATIONS B�VERTER SPEC W-471I0NS OUTPUT—AC ACLOW2 OUi�1Jf chargingLend CaxrctionlOth.SoEdgi Ima1lii.w pletRum Is mqi .d for 6Vdiuginq Rated ACPitwlrOutlait 3800 5000 6000 7600 11400 VA Rated AC Power Output(grid&PV) 9600 W Man.AC Ebner Output 3800 5000 6000 7600 11400 VA Nominal AC Output Voltage 240 Vac AC Qdput Voltage Mw.-Nan-Magic 211-240.264 Vac Nominal AC Frequency so Hr B AC Fmgnnwy pionirp 59.3-60-605W Hz Maximum tirw Conous Output Current 24 /(grid d PV) 40 MC MwinumCuxtkeras WpttGwrsst 16 21 25 32 j 47.5 A Ground Fault Detection Threslwld 5 MMt GFOtThnmhold 1 A ADDITIONAL FEATURES tR,si m nwfkg P—eftt Cale" Yes EV ChugerStatus LED;Pnrtlndlomr x r { UIIPUTEV Charger unpkigging Detection tat,c want s-'.I.m aooardbp to SAE A772 Mnuinum DC ibww 590D 7750 9300 11800 17650 w EV Charger Ground Connection Manitodng tb4 em4ko a5 Unproad.d Yes EVChrgerConRguratlon Viatlrrrtoriloringapp;ENnmk/CePulroF gMetornec&onbrequited Mwrwm knprt WRape 490 Vrdc STANDARD COMPLIANCE NOI*nd DCWUt%felt.9. 380 400 Safety U129O4 UL2231-1.UL2231-2,N6CAM*e625mmpsaiK h nunlnptrtCuuwt 205 13.s 16.5 20 305 Mc EVpwger SAEn77Z-70D9 Max.lnputShortcioukOutwrt 45 Adc INSTALLATION SPECIFICATIONS ft-w-Folr9y Ptatieloe Yves EV OwgerCornecwr sAE 117T2-2009 Gsourd-Fault Isolation Dalaetlon Saw 5anslWhy EV ChngerCahk lengdn w 25/7k fit/m Maxteaen o we so ERftlenncy 992 % ArchrgercahkWrge 12.5/5.7 b/kp CEC YMgtMd HfIciarwy 99 EV werG6leOperaligTempwwpae0arge -22 to+122/-3010+50 F/'C Estee OM PAtig(mnrwOed to EV orwdtduworp) NEMA 3R IIDOfJlt3l�ii k'lIA1'tN1ES -_ � Swporlld Commurtivatlorl ittiletfecax 85485,Ethernet.ZigBee(optlomU,CeRtar(optional) aT am dwap nai.adwea arpwsfy Snnrt aarnt Export Lknitadon and Excess Solar Cswghx}= R wumie Grade Debt ANSI C12.20 OptionaP Iowrlr t"oern6a(Orisg with the 5etApp motile application using built-in Wi-F access point for bee connection Rapid Shin-NBC 3004 and 2D17 M617 Automatic Rapid Shutdown upon AC Grid Disconnect STAN3E SeaNy UL1741.UL1741 SA,(1L1699B,CSA C22.2,Canad n AFO eccordrg to T.LL M-07 Grid Connectionswxh eek IEEE1547,Rule 21.Rule 149 En ois FCC Part 15 Ch s B *! AC Output Corti*gae1R Rage 1'maximum/14-6AWG 1 "1°"/ 14-4 AWG * osns/1 DCNptCar Sian/!d LltYgt/AMK,Rang. ! 1•nwdmum/1-2 stings 114-6 A1NC, 1-3 strings 114--14-6 MVG Mnan(ass with Conrctbss tlnitwlth Sdetdr9wlidt 213 x 14b x731 OkW 17.7x146x68/450x370x174 540x370x1b5 in/mm WaigMvdth Cwrsctbn Unit____*Sdtlt 22/10 258/11A 26.2/11.9 368117A lb/kg Notre <25 <50 tilt E co Nabad Conection Opuaethg Tnrnpessow Ra ge -40 to+140/.40 to+60w Pmtecdon Ming NEMA 4X(Dnvertar with Connection Unit with Safely Switch) t� g3PaiaderieadaIgspiuss. 5fdpwggo.t carwe6ed Fixes solar durriny 6?J ingati0p tnwtrengiiaOtorbpeasi r te q t3fRaa..wp.datwart9a Shundhutaooattwt _*a `, . C E I:d� • r/ ' AAipawuraplaatbeatSDTA2M.rwpowilw- ergWannoWnaneweaHpwMrwaal.edp.caeJdwa -nat.n.vdt ss--moe,wa ` i,® ` t . } rs FC ROHS OSdwrdn} 1<N.natr.NwdfOUVnraar.aw araOMFOtEwa aeavwVwaaOawYWadalrr�r ra . a�e�� AI Wa OII[O/QRwYay@RNwI e�rlefdwrawelatllf 01 INVERTER/EV CHARGER F CONTRACTOR I EC13OO9O2O UNAUTHORIZED USE OF THIS E E RD„' TE BY VER DESCRIPTION D WITHOUT O KEVIN DIETSCH SOLAR BEAR LLC DRAWING SET •_. O R =a't. 1.07 .0 01 INITIAL DESIGN 6101 JOHNS RD STE#8, TAMPA WRITTEN PERMISSION FROM ,' a<< PAPER: 35958 SADDLE PALM WAY,ZEPHYRHILLS FL 33541 FL 33634 CONTRACTOR IS IN VIOLATP4 ARCHB OF U.S.COPYRIGHT LAWS AND €M PH:813-535-6627 WILL BE SUBJECT TO CIVIL SPENCER A.ROBINSON SCALE: PROJECT ID: 0107205E11.47-BAPS VWVW.OURSOLARBEAR.COM DAMAGES AND PROSECUTIONS. PE812550 NTS • r 1 2 I 3 I 4 I 5 I 6 7 8 I 9 / Power Optimizer Tat Carxltlons SIC N yT_ _ 310 For North America 234 . N TTaTTnDoldarT�+TTeT1t(IpTTna14 A 4 - 9 _ 7 P320/P340/P370/p400/p405/p505 Shortdret*curremtOsU -- 4025_ 372 Module 9.93 8�t4 Maximum sN.Rem voltage pin V 1000 wp _ -0%+5 20 PowerTderaxe Mreaetrtaortdklott.Stc100DMWtt2•AM15•Tertperekre25 C-PIOCT800wmx•AM15•MaaturantertttxtrarWnty3ri 'J INPUT __ - - - ,... •ltetarAtYlaratbeadrstatYrettoemodltYxthtm Raudtelbr btelatea decOtul deraetwbtla mNaeyby*5%-. pmm byat sw. Reed"DC Pbaern 320 I 340 370 406 4M 505 W Absalde Mmdm n tput - teffit font Yoc %/I( 0.03 TCo 48 60 b 125 i 67W we -0.30 T Coeftident Plmalr %/K i. -0.38 - AMPTumsi t Range b-41 6-60 8-60 125-165 25-a7 : A&e B +:.�.____�.._...,.`__...,..._..__ -____ _ .-..__._..r.��.__._-__...-..„_...____..� Maximum FartCawtCutrerx 11 D.1 14 'C pt>j -40/+85- - I Mmdmum DC rpm Cvmm 13.75 -125 17.5 Adc Madmum Elder y 995 Module 1 k 19 yr gees 9s6 % Dine nsions x L x D•t 1 mm mm 1650 x 990 x 38 CnvrwRage Caaegary i _— Maldnxlm surfeoebad N/m 2900 Pa Upward/5400 Pa downward j OUTPUT DURING OPERAMlON(POWER OPTia1T�t dDFN1if3t 109IP�FATi96 SOI ARIOGiiVlllReYq Hal impact resbbnce o 25 mm at 83 Ian/h Ma[mum pp*,A Cox 15 Atic Celia --_—___.___60-Si T�oaysmllne-4 or 5 busbOt-15&75 x 156.75 mm j Mmam�m stall vvirege 60 85 Nk Glass 3 2 mm hfgh transmittance tempered.antireflective coatis[ - OUTPUT __._ (OUTPUT DURING STANDBY(POWER OPTStOIølECTW FM SOtAj ) OR t!(J1 Bad heel Frmrnt Muttllaver polyester-based i1VERTER 1 9YDaadIoda _ 10=x14 � w�r+gea' t:at 3 dlodes-45V/12A IP67AP68 Cables and connectors eelretallatIcn ,200 men a 5.7 mm 4 MC4 STANDARD COMPLIANCE EMC fCC Rrrt15 CYa 4 eC6100Pti-2,ECbUR!-63 Module productawanwarra.ngr 5dey IEOR10r-1(daa i w wULV 30 Metww UL94",UV RegWant ULC ORD C7703 UL 1703,IEC 61215 IK 61730 1 and IK 61730 2 Certified. 1NSTALLA710N SPEOIfiCATlON5 FSEC and CEC listed.IEC 62716 Ammonia Corrosion.IEC 61701:2011 Mattltlum Abeted Ssae ym 1009 Product Salt Mist Corrosion Certified UL Flee Rating:Type 2(type 1 on regoesq_ A k%WWS N WmEdge Mwea,d 11ne Rom hormn �- -- �_._.. .--_I Mrors'dns Py x L x M) 129x153x2'75/5.1x6x11 T�x1S3x31.5/ T29x1S9x1951 129;762x59/ mm/n _L..�..____. ._.._.- _.. GiOW1 2019,.,_. 5.,x6xt3 i7r63xt9 5.1;64x23 *PNssereAar66theSafityandlnstaladonManualiarmountlngspecNl®tlons. wtlghc6 cao 603/IA 750/17 ass/t9 1064/23 gr/b ♦Wan ng:Read the Installation and User Manual before handling,Installing and operating modules. o-,p,tcmrecLor MC40 s I" 54019 Wile 016/052 m/R Thld pa tyge aerated pan Ines from 4'str�' ■Modules Per Pallet 26 $ utwiO3.5 WIe'lype/Comectar Ddubte k% tbl/MC4 Fralenhoter-Institute for Solar Energy ■Palets Per Truck 36 �� d Wile 09/295 - 12/39 m/E 9yseatrn BE are avdable for dodrrdioad ewwK ■Modules Per Truck 936 at:WWW.iI(fab601ar.001TUd01Mlbadf 0pva" OeRmge�� - -M-+85/ 0-+185 Y/T �awrae Pn °n Raan9 - ref 9€ Rues__Ems' 0-'160 % 9$ "Reed paaerardernadtlaatS1Cul rat aeeedthe cpt Send YpixDCkwer.MOOkxa i up It+Sspowtol�eae ffemo xae •MC a'171 7t •FarotW v Weua atxa t ern my 'ii •rera-1,=SdScarx .d d==— •t405,nd•am dradd nM4udw•roduW natr.t4 ndtil OMP405 des va0ml, aptMae •F.wN, t•rpareinexrw•ffiC/rU5'Fpasadc-rigk�pttl,atwtopes.rOpMrirxle0- WMDx4bge9lrmdoitfttrmewdrtk 111111 __ I $55g P32(P34U P37(0beer mss) P405/P505 P400 6 9 . - 6 14 h.e 8 Q•bee< 5arsg Length 25 25 SO• 5700900040 t Mmdtrxxn Paver per 5bing 507640420 5011400 5250 6000• 12750" W E SiNabsdarkv- 2WC*#tWAwk0"Gilt = or Orb S5iId Drtererd Lengths Misiea V ON L51TV3 Canada ,ode<W0 Stlfab Td+,9oe ss25m I Fafttt 905L96OI67 r.rrrr_ a • b P 70)M inonxtetq are iJlJ.2Cm lwrrteilhblolarc6m xrrr`�rr a.re,rrrr Axeb anwtle 3o d.x ae vnGA6Wbtpeh.tt3�tN.ebdxhw f.PfeatTfmde4n MOM bSdrinc k Yallfbe >" b apt W 6o9ehsi3lirg 8000orsN tseoxxeOednht►ar+Pmtpro'wit6 6fgySE1a014LV m WA 98225 USA -;+a • �f '�, Tit+13606694733 � �R`�roadl.f;i xex...r twee a t°oert°r'i7mrt"mastwi rr..r..d�w wr.rrs.re�a�rredrarx � - � rMt+rd•w..t•edietrRollS No 81250 MODULE ;Z CiSIMIZER 1t F CONTRACTOR I EC13009020 UNAUTHORIZED USE OF THIS D p TE BY VER DESCRIPTION KEVIN DIETSCH SOLAR BEAR LLC DRAWING SET WITHOUT t m 1►. 1 0724 A 0 01 INITIAL DESIGN �.OZ 6101 JOHNS RD STE#8, TAMPA WRITTEN PERMISSION FROM ¢ :.-�° G ` PAPER: 35958 SADDLE PALM WAY,ZEPHYRHILLS FL 33541 CONTRACTOR IS IN VIOLATIO FL 33634 OF U.S.COPYRIGHT LAWS ANDS ARCHB PH:813-535-6627 WILL BE SUBJECT TO CIVIL SPENCER A.ROBINSON SCALE: PROJECT ID: 010720SIE11.47-BAPS DAMAGES AND PROSECUTIONS. W#N OURSOLARBEAR.COM PE81250 = _________________________________ NTS