Loading...
HomeMy WebLinkAbout20-22463 CITY OF ZEPHYRHILLS i 5335-8th Street (813)780-0020 22463 ELECTRICAL PERMIT PERMIT.INFORMATION LOCATION INFORMATION Permit#:22463 Issued: 2/12/2020 Address: 5320 3RD ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 24,640.00 Total Fees: 307.50 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 307.50 Date Paid: 2/12/2020 Parcel Number: 11-26-21-0010-09600-0130 CONTRACTOR INFORMATION OWNER INFORMATION Name: VIVINT SOLAR DEVELOPER LLC Name: MORRIS, KEVIN & MARY Addr: 1800 W. ASHTON BLVD Address: 5320 3RD ST LEHI, UT. 84043 ZEPHYRHILLS, FL. 33542 Phone: (855)877-2974 Lic: Phone: (813)355-5995 Work Desc: INSTALLATION ROOF MOUNT PHOTOVOLTAIC SOLAR PANEL SYSTEM APPLICATION FEES ELECTRICAL FEE 210.00 BUILDING FEE 97.50 INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL �J REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. CO=OR PER OFFI PXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER / e,3 Tao aazo City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received `` . �r r�^PhoneContactforPernittin 03 "noes Name y (V o I�7 n C f r Owner Phone Number Owners Address 16,320 3 K p 3 T Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address /n JOB ADDRESS 115320 3 R D S I Z 6 P t't/-{Ii 1-1-TI{.S LoT,, �1 SUBDIVISION PARCEL IOk //-2& `2�-00�o - t�9(a0 0-01 J01 (OBTAIN®FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR = COMM = OTHER TYPE OF CONSTRUCTION BLOCK = FRAME = STEEL = DESCRIPTION OF WORK T/1( 6- O UAI L60-tIOR Q p-��7N/�iL BUILDING SIZE SO FOOTAGE HEIGHT II J+``f C r E . BUILDING $ n.2 P (�Q VALUATION OF TOTAL CONSTRUCTION dELECTRICAL $19 7!Z-Da AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO 1 BUILDER / COMPANY T v SIGNATU 1 REGISTERED 'Y/ N I FEE CURREn I Y/N Address 151do Vu.H NNA fl V E TnP,6 A I License# r ELECTRICIAN K O COMPANY SIGNATUREcREGISTERED Y/ N FEE CURREn Y/N Address N r rl,-1 RA license# G 7 V PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEE cuRREn LjLN Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREn Y/N Address License# IIIIt11111111111111111111111111111111111111111111t11111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIaVSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTiLIT1ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOWSIOWNEWS AFFIDAVIT: 1 certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,Water/WastewaterTreatment - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone"A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning,gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR — Subscribed and sworn to(or affirmed)before me this Subscribed and m pmpd) thi by by — Who Ware personally known to me or has/have produced Who islare personally known-to me or-haslhave,praduced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: V) V Date Received: Site: 5"3d o 3, a`l S+ Permit-Type: jhj� Jj � - :S6 1� � �f* yo 1�fl u�► Approved w/no comments. Approved w/the below comments: ❑ Denied w/the below comments: ❑ :x This comet nt s ee all kept with the permit and/or plans. � P Kalvi witzer—Plans Examiner '21a Contractor and/or Homeowner (Required when comments are present) ®®'�' � __, , 1800 INAshton Blvd. ® ® �' `--� r, 13 Lehi, UT 84043 Structural Group J.Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE-Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vivintsolar.com January 28, 2020 Re: Structural Engineering Services Morris Residence 5320 3rd St,Zephyrhills, FL S-6297628; FL-01 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Section: Built-In-Place truss at 24"on center. Survey photos indicate that there was free access to verify the framing size and spacing. • Roof Section: Built-In-Place truss at 24"on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 10.02 PSF= Dead Load (roofing/framing) 3.00 PSF= Dead Load (solar panels/mounting hardware) 13.02 PSF=Total Dead Load 20 PSF= Roof Live Load (based on local requirements) Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website (www.ecofastensolar.com). Page 1 of 2 viAnty = 1 i Page 2 of 2 2. The solar panels are 1%' thick. At no time will the panels be mounted higher than 10" above the existing surface of the roof. 3. The following mounting types shall be used. Please refer to the mounting details for the associated required penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per connection and therefore is adequate. • EcoFasten with Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS)of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered,where possible,to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 48 48 48 Max Uplift Load Ibs 332 266 246 560 448 415 D. Summary Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida Building Code- Residential 6th Edition, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, �%\1IIIII///// J. Matthew Walsh, PE ��� Q' ��ceNSF �•'� FL License No. 84923 nc a� *G = p STATE OF l/lllltl 01/28/2020 v'�/�f�� ` 1800 W Ashton Blvd. ® ® ,� .' I; _:I ! Lehi, UT 84043 Structural Group J.Matthew Walsh,PE Kirk M. Nelson, SE Samuel Brown, PE-Civil Director of Engineering Structural Engineering Structural Engineering james.waish@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vMntsolar.com Structural Design Criteria Project Address Date: January 28,2020 Morris Residence 5320 3rd St Zephyrhills,FL S-6297628 ��P.�4 H E W/ Residence `�� �,,.�,�GENSF • `0 ice/ Risk Category II S Roof Area 2102 sf = * N 84 ; Upper Floor Area 0 sf — Number of Stories 1 STATE OF , Mean Roof height 15 ft O ' X\ Upper Floor height 0 ft i�j �• •'c�OR1OP:""G��\�� Location Parameters S/0NAI- �a���\\ Latitude 28.23477 //1/ 1/28/2020 Longitude -82.18724 Site Class D Risk Category II Existing Gravity Parameters Roof Dead Load 4 psf Composite Shingle 2 psf 3/4"Plywood Sheathing 1 psf Roof Framing @ 24 in.o.c. 2 psf Ceiling,Mechanical,Electrical 1 psf Miscellaneous 10 psf TOTAL Roof Live Load 20 psf Wall Dead Load Ground Snow Load 0 psf 8 ft Wall Height Flat Roof Snow Load 0 psf 300 ft Wall Length 12 psf Wall Weight New Gravity Parameters Roof Dead Load 3.00 psf Solar Panel Weight Roof Live Load with Solar Panels 0 psf Roof Slope Factor 1.0 Roof Slope Factor(ASCE 7-10 Fig.7-2b) Roof Snow Load 0 psf Asce 7-16 Eq.7.4-1 Seismic Parameters SS= 0.068 g 0.2 sec Spectral Response Acceleration SI = 0.034 g 1.0 sec Spectral Response Acceleration Fa= 1.600 g Site Coefficient from ASCE 7-10,Table 11.4-1 Fv= 2.400 Site Coefficient from ASCE 7-10,Table 11.4-2 SDS= 0.073 g Short Period Design Spectral Acceleration SDI= 0.054 g 1 Second Period Design Spectral Acceleration Page 1 of 3 v'vi ' - Wind Parameters Wind Speed 145 mph Exposure Category D Roof Angle, 0 13.0 deg Product Information No.of Panels 35 Weight 3.00 psf including mounting system Installed Area 615.4 ft2 No.of Connectors 46 Total Existing Roof Load=DLRooF+(LLRooF or Snow)x Spacing 60.04 plf Total New Roof Load=DLRooF+DLADD+(LLRooF or Snow)x Spacing 26.04 plf Change in Demand=(Total New Load-Existing Load)/Existing Load -56.63% Total New.Gravity Loads are less than Existing Loads.OK Code References 2015 IEBC Section 707.2 states: "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. EXCEPTION 1.Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." 2015 IRC Section AJ501.4 states: "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous condition is not created.Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code." 2017 FBC Section AJ104.1 states: "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated." Page 2 of 3 iv' ® Wind Uplift Simplified Procedure for Components and Cladding ASCE 7-10,Section 30.5 V= 145 mph Basic Wind Speed Exposure D ASCE 7-10,Section 26.7 = 1.47 Adjustment Factor for building height,ASCE 7-10,Figure 30.5-1 Kn= 1 Topographic Factor,ASCE 7-10,Section 26.8.2 Roof 0= 13.0 deg sanohor= 48 in Horizontal spacing of roof anchors Atrib= 21.60 sf Panel Area tributary to each roof anchor Pnet30 Net Wind Design Pressure,ASCE 7-10,Figure 30.5-1 Roof Zone Zone 1 Zone 2 Zone 3 As shown in ASCE 7-10,Figure 30.5-1 31.5 psf 49.1 psf 89.3 psf Pnet=AYI-0ne130= Design Wind Uplift Pressure,ASCE 7-10,Equation 30.5-1 Zone 1 Zone 2 Zone 3 46 psf 72 psf 131 psf Pnet= 16 psf Minimum Design Wind Pressure,ASCE 7-10,Section 30.2.2 Use 46 psf Use 72 psf Use 131 psf Connection to Existing Roof Framing F.S.= 1 Additional Factor of Safety applied to withdrawal force,if desired Atrib= 21.60 ft` DLpanel= 3.00 psf Zone 1 Zone 2 Zone 3 WaPlig= 46 psf 72 psf 131 psf Piag=F.S.x Atrib x(0.61)-0.6W) Withdrawal force for each roof anchor Zone 1 Zone 2 Zone 3 -560.3lbs -448.3lbs -415.4lbs Connection Capacity db= 5/16 in Lag Screw diameter DpeR= 2.50 in Lag Screw penetration into existing framing member Southern Pine Species of wood framing CD= 1.6 Load Duration Factor for Wind Loading,NDS Table 2.3.2 Ct= 0.7 Temperature Factor,NDS Table 10.3.4 W= 235 lb/in Withdrawal Capacity NDS Equation 12.2-1 W'=CD x Ct x W= 263 lb/in Adjusted withdrawal value Panow=Dpen x W,= 6571bs Based on penetration depth Zone 1 Zone 2 Zone 3 DEMAND= 560 lbs 448 lbs 415 lbs Max Load=0.853 OK CAPACITY= 657 lbs 657 lbs 657 lbs Page 3 of 3 vivint. ,) ' www.jinkosolar.com Building Your Trust in Solar PERC PEDC 60 ; EAU'le wx WaU MORO ® a ®, r ■ Positive powaftolerance of 0-+30/. r IS09001-2008.,IS1014001i2Qe4 • :11 certified,factory� ■ A certified.products. ■ ■ ■ ■ ■ ■ KEY FEATURES 4 Busbar Solar Cell: 4 busbar solar cell adopts new technology to improve the efficiency of ..� modules,offers a better aesthetic appearance,making it perfect for rooftop installation. . ® High Efficiency: Higher module conversion efficiency(up to 18.33%)benefit from Passivated ®®®® comrensros Emmiter Rear Contact(PERC) technology. PID RESISTANT: Limited power degradation of Eagle module caused by PID effect is rao u[.vz,aHi guaranteed under strict testing condition (85 C/85%RH.96hours)for mass .•�®�® Production. i Low-light Performance: Advanced glass and solar cell surface texturing allow for excellent i r.® �owuoer performance in low-light environments. Severe Weather Resilience: . a 2°00Pi Certified to withstand:wind load(2400 Pascal)and snow load(5400 Pascal). .r 54DO Pa ■ Durability against extreme environmental conditions: ncsr!s,� High salt mist and ammonia resistance certified by TUV NORD. for I LINEAR PERFORMANCE WARRANTY 10 Year Product warranty • 25 Year Linear Power Warranty PV CYCLE NOW �_ C � J ENERGY POSITIVE QUALITY' MEMBER t00% ® linear performance warranty m 97% Arytyiti Standard performance warranty es% opal value from Jrr,ko `w eo% Solar"ft66ftft._ v ea.z% c7 y 1 5 12 75ears o t .•. e 2 H2a5 %"_' Current-Voltage 8 Power-Voltage Temperature Dependence Curves(290" of Isc,Voc,Pmax •••-••.• Ito a _ / �,•, lea 2 300 �ISO 6 zso u IA K S Isc Q VOC +. .,/••m B max 2 m 50 Zas 0 a 2a q j 0 5 10 15 20 25 30 35 as F.I. Front Sid. Back se -25 0 25 so ;s 100 Voltage(V) Cell Temperatu,e(Q 1 Characteristics s Ji Cell Type Mono-crystalline PERC 156x156mm(6 inch) No.of cells 60(6x10') n Dimensions 1650x992x40mm(6S.00x39.05x1.57 inch) Weight 19.0 kg(41.91bs) Front Glass 3.Zmm,Anti-Reflection Coating, l High Tra_nsmission,Low Iron,Tempered Glass - Packaging Configuration l Frame Anodized Aluminium Alloy (Two boxes=one pallet) Junction Box IP67 Rated 26pcs/box,52pcs/pallet,728 pcs/40'HQ Container Output Cables TUV 1 x4.Omm;Length:900mm or Customized Length SPECIFICATIONS Module Type JKM280M-60 JKM285M-60 JKM290M-60 JKM295M-60 JKM300M-60 STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power(Pmax) 280Wp1 209Wp 285Wp 212Wp 290Wp 216Wp 295Wp 220Wp 300Wp 224Wp Maximum Power Voltage(Vmp) 31.8V 29.7V 32.OV 29.9V 32.2V 30.2V 32.4V 30AV 32.6V 30.6V Maximum Power Current(Imp) 8.81A! 7.01A 8.9DA 7.12A 9.02A 7.15A 9.10A 7.24A 9.21A 7.32A Open-circu it Voltage(Voc) 38.6VI 36.2V 38.7V 36.4V 39.5V 36.6V 39.7V 36.8V 40.1V 37.OV Short-circuit Current(Isc) 9.49A'l 7.62A 9.51A 7.72A 9.55A 7.81A 9.61A 7.89A 9.72A 8.01A Module Efficiency STC(%) 17.11% 17.41% 17.72% 18.02% 18.33% Operating Temperature(C) 40°C-+85°C Maximum system voltage 1000VDC(I EC) Maximum series fuse rating 16A Power tolerance D-+3% Temperature coefficients of Pmax -0.39%/°C Temperature coefficients of Voc -0.29%t°C Temperature coefficients of Isc 0.05%/°C Nominal operating cell temperature (NOCT) 45±2°C 'STC: Z"-irradiance 1000W/mz j��Cell Temperature 25°C „^,j AM=1.5 NOCT: =Irradiance 80OW/m' Ambient Temperature 20°C ; AM=1.5 Wind Speed 1m/s Power measurement tolerance:±3% II The company reserves the final right for explanation on any of the information presented hereby.EN-JKM-300M-60-PERC_1.0_rev2017 a! Si e phase Inv Single ph rtefs solarEdge OON-us � or North America f E3$OON-us 1 SESOOON- SE3aOON_us SE760OH-U5 ' { ", < #A , 3 t % } 1.. k y 4 S liation D.W.aVe teChn®IogY _ to with N tlmi�ed ins to workwith power opt+mizers article 690.11 and�ig0.12T, Spec'fically designed d 2Q1?,per efficiency for NEC 2014 an breaking, &-strings . Record- e inVerter for long d rapid shutdown . Fixed voltag rid compliance V`r arc fault protection an Integrated d for CPUC Rule 21 g ors or Ind°ors . Integ < t111?41 SA certifie , to Install outdo capacitors mall and easy c without any electrolyfi www.solaredge.us s : Extremely Q,SoJa accuracy ,r f-►igh reliability onitoring I C12.20 Class 0.5 OdUle�eVe1 m RN4R_}{UNGARY-swepev- guilt in m de data,p,NS Y kNDIA'BULGARtA ftOM 1 Revenue 113BELG4UM TURKE s Qpn°nal.. iSRPEt-FRANCE' USA-CAN RDA-GERMANY-JKiTAIY-TNE NETNERLPNDy IPPAN"CNkNA"PUSTFRLtA' SOUTN PERiCA-POLPND-C2ECNREpUBLIC solar=a@ z Single Phase Inverters for North America SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/SE760OH-US SE3000H-US I SE380OH-US SESOOOH-US I SE6000H-US I SE760OH-US OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA ............................... .................... .................... .................... .................... .................... ............. Max.AC Power Output 3000 3800 5000 6000 7600 VA ........................................................... .................... .................... .................... .................... .................... ............. AC Output Voltage Min.-Nom.-Max.(183 208 229) ✓ Vac ........................................................... ................... .................... .................... .................... .................... ............. AC Output Voltage Min:Nom:Max.(211-240-264) ✓ ✓ ✓ ✓ ✓ Vac ........................................................... .................... .................... ..................i. .................... .................... ............. AC Frequency(Nominal) 59.3-60-60.5 Hz Maximum Continuous Output Current 208V......... _........ _........ 2a.. _........ _........ A'..... .Maximum Continuous Output Current 240V 12.5........ .........16.........I.........21.........1.........25.........f 32......... .....A...... ............................... GFDI Threshold A ........................................................... .............................................. 1 ................................................. Utility Monitoring,Islanding Protection, Yes -Country Configurable Thresholds INPUT Maximum DC Power 4650 5900 7750 9300 11800 W ....................................................... .................... .................... .................... .................... .................... ............. Transformer-less,Ungrounded Yes ........................................................... ........................................................................................................ ............. Maximum Input Voltage 480 Vdc ......................................................... ................................................................................... .................... ............. Nominal DC Input Voltage 380 400 Vdc ........................................................... .................... .............. ............ Maximum Input Current 208V i'1...................... ..........:......... ..........:............ .......... .......13.5..... .. .. .......:......... ..........:......... ....Adc ......... Maximum Input Current 240V. 1................... 85... 10:5........ .......13:5.................16:5........ .........?0......... ....Adc..... Max.Input Short Circuit Current 45 Adc ........................................................... ........................................................................................................ ............. Reverse-Polarity Protection Yes ......................................................... ........................................................................................................ ............. Ground-Fault Isolation Detection 600ksa.Sensitivity .. ...................................................... ............. Maximum Inverter.Efficiency ...... 99. I.......................................99.2 CEC Weighted Efficiency 99 % Nig httime Power C on s ump lion <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) .................................................... ....................................................................... ............. Revenue Grade Data,ANSI C12.20 Optional ........................................................... ............................................... ............. Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I:L:M-07 .................................... .......................... .................................... . .. ... ....... Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) ........................................................... ....................................................................................I................... ............. Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 0.75-1" Conduit/14-6 AWG ........................................................... ........................................................................................................ ............. DC Input Conduit Size/#of Strings/AWG Range 0.75-1" Conduit/1-2 strings/14-6 AWG ........................................................... .... ................................................................................................... ............. Dimensions with Safety Switch(HXWXD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm .................... ......................................... ............. kg Weight with Safety Switch..... ......... ............. ........22/1.... ........I....25.1/11 4....I..................../1.................. .. Ib/....... Noise <25 <50 dBA Natural convection and Cooling Natural Convection internal fan (user ........................................................... ...................................................................... re laceable Operating Temperature Range -13 to+140/-25 to+60111(-40'F/-40°C option)15) °F/'C ............................................I.............. ........................................ ) ................................................................ ............. Protection Rating NEMA 3R(Inverter with SafetySwitch Iq For other regional settings please contact SolarEdge support u1 A higher current source may be used;the inverter will limit its input current to the values stated 131 Revenue grade inverter P/N:SExxxxH-USOOONNC2 Pi Power de-rating from 50'C Isi-40 version P/N:SEx—H-US000NNU4 Rol,Hi O 1 • D • OPTIMIZED BY / • D r,1 - 1• 1 I - - - e } STATE OF FLORIDA,COUNTY OF PASCO -� THIS IS TO CERTIFY THAT THE FOREGOING IS A a lit 4 TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE .' W TNESS MY HAND A FFICIAL SEAL T.IS DA F 2 L V NIKKI ALVAR -SO L S, CLERK&CoMp�°R� D � BY DEPUTyCLERK INSTR#2020023893 OR BK 10051 -PG 3292 Page 1 of 1_ — 02/12/2020 11:02 AM Rcpt:2134546 Rec: 10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq., Pasco County Clerk&Comptroller r ... - e Permit No. ParrxilIDNo 0010 Me0Q'01'0 NOTICE OF COMMENCEMENT Stele of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement wa be made to certain real property,and in accordance with Chapter713.Florida Statutes, the following information is provided in this Notice of Commencement 1. Description of Property.Parcel identification No. Street Address: a_f KY r 111 S ti-� 2. General Description of Improvement Installation of a roof-mounted solar photovoltaic system 3. Owner Irdormation or Lessee information if the Lessee contracted farthe improvement K c�.�, r`1o'„S �'j T v 3 r r S 1- Z e tick Address city State Interest in Property: Name of Fee Simple Titleholdar. (If different from Owner listed above) 4. cedress nbactor. Vivint Solar Developer,LLC city state Name FL 5100 W.Hanna Ave. Tampa Address City state Contractors Telephone No.: (813)358-0834 5. Surety: Name Address City State Amount of Bond:S Telephone No.: 8. Lender. Name Address Cfry state lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon wham notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address City state Telephone Number of Designated Person: 8. ,;., In addition to himself,the owner designates of to receive a copy of the Uenors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. S. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date Is specified): B lia g i s . 2 0 ZO WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION-IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of comma Mani and that thV§ffi stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signature of er or Lessee,or Owners or Lessee's Authorized Ofter/Direrto artner/Manager k er if S' Signatory's Title/Office The foregoing instrument was acknowledged before me this22 7�day of,J(' 20 Zg by as (type of authority,e.g.,officer,trustee,attorney in fact)for .ti L, Oi4 ✓Owl`Lt'1 (name of an behalf of whom Instrument was executed). Persanaly Known[I OR Produced Identifications Notary Signature !, / Type of Identification Produced t • ID✓'� '.L'e7f ne(Print) L re-7 0 t/ Cf o W t o N pupl(C�Be�t 1FA� w)data/brs/nodcemmmencementyc053048 ce l f 1 I No" '' s STATE OF FLORIDA,COUNTY OF PASCO 4,`, w..- .. . THIS IS TO CERTIFY THAT THE FOREGOING IS A 7l b•..: TRUE AND CORRECT COPY OF THE DOCUMENT i ON FILE OR OF PUBLIC RECORD IN THIS OFFICE ' nt W TNESS MY HAND A FFICIAL SEAL T IS _� DA F 2 NIKKI ALVAR -SO L. CLERK &COMPTROLLER BY DEPUTY CLERK