Loading...
HomeMy WebLinkAbout20-22500 CITY OF ZEPHYRHILLS 5335-8TH STREET t. (813)780-0020 22500 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:22500 Issued: 2/21/2020 Address: 3132 NUBBIN RIDGE LN Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 19,002.47 Subdivision: HIDDEN RIVER Amount Paid: 19,002.47 Date Paid: 2/21/2020 Parcel Number: 24-26-21-0110-00000-2690 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607-5995 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT APPLICATION FEES PLUMBING FEE 198.75 SEWER CONNECTION RE IDEW 2,090.00 ELECTRICAL FEE 298.13 WATER CONNECTION RESIDENI 1,010.00 MECHANICAL FEE 139.13 SCHOOL IMPACT FEE-sfr/1% 83.28 SCHOOL IMPACT FEE-sfr/100% 8,328.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 WATER METER RES 3/4" 473.78 BUILDING FEE 1,426.49 POLICE IMPACT FEE 254.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 FIRE IMPACT FEE 273.00 �G Inspections Required. FO TER 2ND ROU H PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits'required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ONTRACTORS G AT E PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlt CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#12020030136 OR BK 10066 PO 2847 Page 1 of 1 D2/2012020 11:56 AM Rept:2137341 Rec 10.00 DS:D.00 IT:0.00 Nlkk)AlvaurzSowles,Esq.,Peso*County Clerk&Comptroller Permit No.- Psrool lD No 24-26.21-0110-00001-2690 - NOTICE OF COMMENCEMENT state of Florida Caanly of - Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to conahi real property,and In accordance with Chapter 713,Florida Statutes, the fclowirrg information Is provided In this Notice ofCommencement 1. Description of Property:Legal HIDDEN RIVER PHASE 2 PS 79 PGS 102-110 LOT 269 - StreetAddress: .3132 Nubbin Ridge Lane Zephryhils FL 33541 2. General Description of Improvement Single Family Residence 1 Pool/Screen Enclosure/Fence - 3. Owner ,lah mador, Lennar Homes,LLC.Nam - _ - 4GQU W CyF1 3 Sits 200 Tikrnpa - FL 33607 �A interest in Pmperhr coy E�r Name of Fee Simple Titleholder=N/A (Itotherthen owner) -- - - - - '��• 4, Ad state Lennar Homes;LLC -— - - - v 4600 w Cvvress St,Ste 200 _ _ Tannins - _ FLy 33807 Address City Stale - Confractaes Telephone No: 813,574.5700 5. Surety:`7,7--�i NIA • (tom" Name - * - _ ,• "� Address - City -- -- Stara _ -•,✓'f�q . Amount of Sand:$ Telephone Na.: 6_ Landar. NIA Nuns Address - - 'City - Smle Lender's Telephone No: 7_ Persons within the State of Florida designated by the owner upon whom notioas or atter documents may be served as provided by SeNon 713.13(1)(a)(7),Fbdda Statuias: X. 1 Lerinar.Ham"es LLC J W Name ._.1 4500 W Cypress St.Ste 200 Tamos FL•,33607 IZ En 0 0 ; Address - _ �Y -_ Slate i _ Taiephone Number oftxstgnatedParsom 813.674.5700 (D 10 i C- }' CJ 7 ti} t CV 5 a. In addition to himsett.the owner desigrrstes NIA - Of— 0 o O — 0 W to receive a copy of the Lianors Notice as proNded In Section 713.13(1)(b),Florida Statutes. L`3 r Telephone Number of Person or Err*Designated by Owner. - ix LnJ Z --t U. DSp < 0. Expha6onn date of"on of Commencement is one year from the dote of remrtgng unless a difforard date is$pacified: 0 ll CJ CC WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT i I 0 >- O O U- U ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER713, PART1 SECTION713.13, FLORIDA STATUTES, AND CAN Z (a RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPbiN A NOTICE OF COMMENCEMENT MUST BE t RE.CORDEO AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ULa , STATE OF FLORIDA m (� Lt- COUNTY OF PINELLAS �J' V' - }. O is iil 7 Sldlimumef Owner or Owrnet"aAutionized ORcer101redorrPertner/Manager Vice President W E'+ LLJ Slgnatoys 7ltlerOfdce I C) 0� Cr' The foregoing instrument was acknowledged before ma Oda 2?day of January by L6 C7 G p Steve Robert Smith as Vice President fact) r 7 LL I < (type of authority,e.g.officer,Weise,attorney to fa for i Ul U) Q. J LiJ Oo Lennar Homes,LLC (nameofpan Am insmmrantwasexecated). � (n � � r �_ Personalty Known IN98 Produced rdendfasUon ElNotary Slgnat �"�----+ p IT-* Z' ? CO vt r i— > Z CO Type of Identification Produced Name(Print). El issaHolleran . Verification pursuant to Section OZ525,Florida Statutes.Under penalties of perjury,I dedam that I have read the foregoing and that the facts stated In it are true to the best of my Imowledge,and belief. O&WHIMIDA u3sAM. signal N�SlgrtngAbove�lralits 10 FB8tW WpdatalbcolbrsfomxTtiRWIMsaaasa3"ll Lennar Homes-3132 Nubbin Ridge Lane-2,276 sgft Column Its SO. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - �o TOTAL: $ 3,100.00 / WATER METER: $ 473.78 IRRIGATION METER $ FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: v PERMIT TOTAL �I TOTAL: $ - PUBLIC SAFETY IMPACT FEES I POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 I s SUB-TOTAL $ 6,189.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 8,328.00 100.0% $ 8,328.00 1.0% $ 83.28 TOTAL: $ 8,411.28 T I F'S : $ 3,632.00 qq%l $ 3,595.68 1%1 $ 36.32 TOTAL: $ 19,002.47 PASCO COUN 11Y, FLORIDA i Permit No. •7 5W I I Date Permitted 2-i q-?o Builder Name/Owner Name �..,.eAn-a.r `L fte-41 LL Control#' " County Parcel No. _� �2(p—Z L d It 0-^6owo-20c) SubDiv: �eA Address/Location Z iUu �b+ii A-d Ce _fa.rp Classification/Type of Use r; TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z7�� ? Exempt ❑-fes ❑ No How Determined Impact Fee Amount p. $. ,�32,Q "Zone No. TAM SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ j�� l� t f (057) Mobile Home `s (056) Other Residential 123) Collection Fee Exempt Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total r. Zone TOTAL AMOUNT $ -7(09_s6 ? Exempt ❑Yes ❑ No How Determined f y; '- LIBRARY FEE Land Accounf Land Credit Land Total :} Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amours RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED.OR FINAL,INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE Y BEEN PAID AND. u: RECEIPTED FOR BY A CENTRAL PERMITTING OFFICFwOF PASCO COUNTY s Acknowledgement below does not Imply acceptance of concurrence,but simply receipt ofa copy of this form,placing the building permit owner,on notice of this assessment and fhq conditions of payment Or same. c DATE RECEIVED BY RECEIPT NO. DATE BY 24-26-21-0110-00000-2690 1 Pasco County Property Appraiser Page 1 of 1 Parcel ID 24-26-21-0110-00000-2690 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $29,258 TAMPA , FL 33607-5995 Building $0 Extra Features $0 Physical Address 3132 NUBBIN RIDGE LANE, ZEPHYRHILLS, FL 33540 Just Value $29,258 Assessed (Non-School Amendment 1) $29,258 Legal Description (First 200 characters) HIDDEN RIVER PHASE 2 PB 79 PG Non-School Taxable Value $29,258 102 LOT 269 School District Taxable Value $29,258 Jurisdiction CITY OF ZEPHYRHILLS _ Land Detail (Card: 1 of 1) Line�Use_._ Code Description Xoning,Units_ Type ;Price ConditioniValue _ T1 10100V SFR� MPUD 6,000.00 SF ) $4175 -�1.00 $28,500 �2 i 0100V j C 2( �^ SFR T —� MPUD 842.00 1 SF $0;90 1.00 $758 Additional Land Information __ Acres _Tax Area FEM_A_Code Res Code-1--Com;Code j Condo Code 0.16 30ZH ��� HDRV ----.jW HDRV Y i HDRV Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) Line ode Description jYear Onits~� Value No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC Month/Year_ !Book/Page _ Type DOR Code ,Condition rAmount 01/2019-__L9854 / 3547�, _ Warranty Deed f 05 ...... -1_ Vacant $4,965,000 09/2011 8606 / 3376_ __ Warranty Deed 05 i_� Vacant $0 06/2010 1 8360 / 1872 _j Certificate of Title 12 Vacant $0 12/2005 1!_ 6748 / 0894_~-- Warranty Deed - Vacant `j- $0 —_ 12/2005_ 6748 / 0891 Warranty Deed j Vacant ? $0 12/2005 f 6748 / 0889 f Warranty Deed j Vacant j $0 I I https:Hsearch.pascopa.com/parcel.aspx?parcel=2126240110000002690 2/19/2020 Q j • ED I Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to.cornply with R401.3 of the F.B.C. 3. Compaction test required'if 24" or more of fill dirt is brought in at-any one place. 4: Tie in survey required before pouring concrete. 5; Driveways require.a R.O.W. use permit_. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be in et. 7. All property markers shall be uncovered and marked at time of first inspection. & All A.D.A.-requirements shall be met: . 9: No electric,plumbing, mechanical, or framing shall be covered without an inspection.and approval first: 10. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). 1.1. Appliances shall not be installed in a location.where subject.to mechanical damage unless protected by approved barriers. M3014 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308.:1 14. Return air in all bedrooms. F.B.C' .. M1620.4 1.5. Smoke detectors are to be- installed in accordance with R313:1 of the F.B.C. 16. All glazing requirements are to be in accordance:with R308A.of the .RC. 17. All means of egress are to;be in accordance with R311 of the F.B.C.; 18. "Green gypsum,board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage.' They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit;to unit. This includes all underground plumbing and electric. 22. All 201-6 N.E.C. Codes will be enforced: T-` 23..Tamper- Resistant Receptacles in accordance with 406.11 ofthe 2016 N.E:C 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25:.R403.5.3Hot water pipe insulation Insulation for hot.water-pipe with'a minimum thermal resistance (R-value) of R-3 shall.be applied to the following: Piping V.inch (19.1 mm)and larger in.nominal.diameter. Piping serving more-than one dwelling unit. Piping located outside the conditioned space. Piping from the water heater to a distribution manifold.. Piping located under a floor slab: Buried in piping. :Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O. 26.A copy of the ene''my cacls shall be with permit at all times- 27. Copy of rnal insulation report shall be provided ivith Permit before fnaL 28. No fence,-pool or'screen enclosure :is issued with this permit F.F.E.-Finished Floor Elevation F.B.C-.Florida Building Code 6"'Edition R.O.W-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric;Code (2016) j I �I j | ! � 313-780-0020 City o«ZepnyrDU\s Permit Application Building Department Date Received Phone Contact 813 2891 Owner's Name rLe'n Owner Phone Number Owner,s Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address F JOB ADDRESS F3132 Nubbin Ridge Lane (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED F.71 womcomsnR AoDmLT [---� n|Gw [--1 !` [--1 DEMOLISH [ ] INSTALL L-1 REPAIR / PROPOSED USE SFR COMM OTHER. TYPE OF CONSTRUCTION BLOCK FRAME STEEL amily Residence/Pool Screen Enclosure Fence DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE HEIGHT 1 Story I V/ BUILDING VALUATION OF TOTAL CONSTRUCTION AMP SERVICE MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION I =GAS ROOFING F__1 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES 0 BUILDER COMPANY I SIGNATURE REGISTERED Y/ N FEE CURREN YIN ELECTRICIAN COMPANY Edmonson Electric,li Inc. Address 11034 Skipper Road,Tamp-a, FL 34WM License# I EIC 13005408 PLUMBER COMPANY Bayonet Plumbing, keating &AC Inc SIGNATURE /Z REGISTERED Y/ N FEE CURREN LILN J ------- COMPANY =Bayonet Plumbing,-Oeating &A ucenoew OTHER COMPANY C Sterling Quality R,bofing, Inc Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# FCc' RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new co�hstruction, Minimum ten(10)working days after submittal date, Required onsife,Construction Plans,Stormwa ter Plans wl Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.,R-6-0 Permit for new construction. Minimum ten(10)working daysaftor submiftal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence instailed, Sanitary Facilities&I dumpotec Site Work Pennitlo,all new projects.All commercial requoementt must meet compliance SIGN PERMIT Attach(2)sets m Engineered Plans, ^°°PnopEnTv SURVEY required for all NEW construction, Owner&Contractor sign back of application,notarized, If over .$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone wiith notarized letter from own&I authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Fill out application completely. ./ i , r NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,'they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify;that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work ' will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance 'of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to' be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN AeTTORNEY BEFORE RECORDING YOUR NOTICE W COMMENCEMENT. FLORIDA JURAT(F.S. A 7.03) — OWNER OR AGENT CONTRACTOR/Vi/I Subscribed and swor to rme a re rKe this Subscribed and 4W56TrWoi affi ed)before me this LL-Ja"-Lu by_AstRee Callahan 22-Jan-20 by Ashlee Callahan Who is/are personally known to me or Who is/are personally known to me or as identification. as identification. / Notary Public Notary Public Commission No. FF985637 Commission No. FF985637 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped l�.I�S1V41rF1l71.t�ApW � . 4 Cwrtmy�'ca dp(r1il3E17 �Rm�i'an NPPe14017 " • ��M���,�t�„�,�a�d .. �i3+r�trrr,�,�r,���wrns���cae�,�al>< ,., k-1iw'thT.VrdI I'm Ihakl�K,119�t+11 FF 73.55 °4 't . . 315 i I .� 4 k 285 :ter -- - - - - - - -- - —� FF EL 4 f FFEL 73.20 ' i A r B• 273 i 3 73.35 I — — — -- �• - FFEL - - A f 2$6:, 73.50 r ; FF EL 1 ! i . FF EL` L `z A tft+ fr 73.40 272 d ? ? 73.05 — ^' p,l a 314 it r -- _ _ ,' ` ?�'• � � �'�3�. �`� ! � NJ 4.00 ",. + # iFF EL i i� FF EL F A s ' 73.70 71 j r 72.75Ilk 288`!f f FF EL ; —FF EL 1 ;' FF EL 1' F f' 74.00 72.45 _ _ B 270 , / j f FVEL 1; _. - ! �€EF ELF:;;;:`—,-= _ fit FF ELi - 4 289 T � 35 ,;• ` SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E. PLOT PLAX NOT A BOUNDARY SURVEY LOT 269 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00'23'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES i ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DATA SHOWN HEREON BASED ON THE ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENGINEERING PLANS OF KIMLEY—HORN AND ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. LEGEND: —v,A— = PROPOSED DRAINAGE FLOW 10' PUBLIC UTILITY EASEMENT (00.00) = PROPOSED GRADE E-00.00 = EXISTING GRADE ON LOT AREA CALCULATIONS NOTES: LOT' =_68_41-39 SQ. FT. LOT GRADING TYPE = B 6 LIVING AREA 1838 S0. FT. PROPOSED PAD ELEVATION N/A ENTRY --12--SO. FT. FRONT SETBACK = 20' t GARAGE 406 —SQ, FT. SIDE SETBACK = 10' COVERED LANAI N/A —SQ. FT. PATIO 23 Q. FT. REAR SETBACK 10' CONC. DRIVE FT. A/C & CONC PAD =9—..__SQ. FT. PRIVATE SIDEWALK FT. IMPERVIOUS 2677 SQ. FT. SOD 4164 —SQ. FT. OFF LOT AREA CALCULATIONS RIGHT OF WAY =__7QQ_2_SQ. FT. DRIVE APRON =__L2_8SQ. FT. PUBLIC SIDEWALK =_ 235__-SQ. FT. SOD FT. .......2 00' LOT 270 TOTALS AREA =__Z5_U—.97-SQ. FT. ..... ... DRIVEWAY 425 --SQ. FT. S 77-14-42" SIDEWALK 30_q_7SQ. FT. .. ....... CN, --ulo- 07 i6 CS o". 110.00. SOD —__.i5_02SO. FT. 1 1.69, 7527 6- w 59'-4- Cb ......... CL z aD 'S N 6. 00. V ci LOT 269 2 4.00. 67- 0. w K N _N k 491, .99 Jra QOO, LOT 26B PLAT BOUNDARY tpc(p) PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 74.35' rn GARAGE AREA: N/A 1� w ELEVATIONS REFERENCED TO 0 NATIONAL GEODETIC VERTICAL DATUM OF 1929. MEAN SEA DESCRIPTION: DATUM 00.00 FT. oi LOT 269, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", w AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH CURVE iAD S ARC CHORD I BEA RINGG I DELTA CO�5 0 40%0. 1 85Z6' 1 85!33- 1 S 18'56-16" W 1 05-12.10" 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. I C164 1 1050.00, 65.64- 1 65.63' 1 S 14-32-45- W 03-34.54" C185 1 940.00- 1 58.76' 1 58.75' 1 N 14'32'45" E I APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101CO458F EFFECTIVE DATE: 09/26/2014 1Square Peet: 6841.39 d: LENNAR HOMES LEGEND: z Lu(C)= CALCULATED DATA, (0)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED.-E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, tV F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON,ROD, FN&,D=-FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS,= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493,,§N&D= SE-T-NAIL-& DISK No.4493, TBM= TEMPORARY 2 BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENZ Drawn By: w JOHN R.BEACH&ASSOCIATES,INC. SMS SURVEYORS AND MAPPERS Checked By: C t 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 ale: WAY (813) 854-1276 FAX (813) 855-5370 Sc 1"=30' c: NOT VALID WITHOUT ORIGINAL SIGNATURE IDote: PLOT PLAN 01/31/2020 RTM 0 AND SEAL OF A FLORIDA LICENSED N­ DATE SURVEYOR AND MAPPER JOHN'R. CH m Revisions: FLORIDA RE AND.SURVEYOR No. 2981 LB#4493 JEFF M. HAWLEY PROggeSITNAL SURVEYOR &'MAPPER No.7123