Loading...
HomeMy WebLinkAbout20-22502 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22502 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:22502 Issued: 2/21/2020 Address: 3172 LYTTON HALL DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 342,906.60 Total Fees: 19,647.47 Subdivision: HIDDEN RIVER Amount Paid: 19,647.47 Date Paid: 2/21/2020 Parcel Number: 24-26-21-0110-00000-3120 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607-5995 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,044 SQ FT APPLICATION FEES PLUMBING FEE 263.25 SEWER CONNECTION RE IDEW 2,090.00 ELECTRICAL FEE 394.88 WATER CONNECTION RESIDENT 1,010.00 MECHANICAL FEE 184.28 SCHOOL IMPACT FEE-sfr/1% 83.28 SCHOOL IMPACT FEE-sfr/100% 8,328.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 PARK FEES SF 769.56 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 BUILDING FEE 1,865.09 WATER METER RES 3/4" 473.78 'p 4 Inspections Required . FOOTER 2ND ROUGH PLUMB MIS INS U LATI N EILIN FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. TRAC _SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes-3172 lytton Hall Dr:3,044 sqft Column SQ. FEET PRICE MAIN OR LIVING: 3,044 $ 112.651 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 342,906.60 FEE SHEET $ 1,755.00 ADDRESS $ 30.00 DRIVEWAYI $ 45.00 BUILDING: $ 1,865.10 ELECTRICAL: $ 394.88 PLUMBING: $ 263.25 MECHANICAL: $ 184.28 SUB-TOTAL $ 2,707.50 TOTAL $ 2,707.50 o �/ SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:j $ 473.78 �- IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: '�3 PERMIT TOTAL TOTAL: $ - 708 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 1 -3 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,834.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 8,328.00 100.0% $ 8,328.00 1.0% $ 83.28 TOTAL: $ 8,411.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 19,647.47 I I INSTi*202003Q144 011 6K 10056 PG 2855 Page 1 of 1 02/20/2020 11:56 AM Ropt.2137341 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-5owles,Esq.,Pasco County Clerk&Comptroller I - i j ParmttNo, ParcellDNo 24-25-21-0110-000003120 NOTICE OF COMMENCEMENT -stale of Florida _ County at Pasco THE UNDERSIGNED hereby gives notice that hnprouemem wR be made to certain real property,and In accordance with Chapter 713,Florida Stehdea, the following Information Is provided in this Notice of Commencement 1. Description of property,Legal HIDDEN RIVER PHASE 2 PS 79 PGS 102-110 LOT 312 - - - StreetAddress 3172 Lytton Hal)Drive zephryhills FL 33541 2. General Description of Improvement Single Fprttily Residence/Pool/Screen-Enclosure/Fence 3. owner Information: Lannar Harms,LLC, _ Nsme... , 4600 W C4oress StE'Ste 200 Tamara - FL-U607 Address '- --- _ city State interest in Property: - Name or Fee Simple Titleholder. N/A - - - (0otherthan ownerl -- 4. -Adds ma dt� city stela r: Lennar Homes,LLC C 4600 W Cyvreess Si,.ste zoo_ - Tampa FL•33a07 Address - --- - - City- - State `Jiri _ _ • Contractar'c TelaFbone Na.: 813.574.5700 s. surety.: `. NIA - - g,' 'X, n' Mama t f: Address city Statec wl%�' Amaunf at Band:S - Telephone No.• ' 9. Lender- - .• ��Z �.Hama - State 1 m ` Address ��y -� --- - _ Leaders Telephoto No: 7. Persons within the Stale of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(t)(a)(7),Florida Statutes: Lenna>r NomPILC` - 77 e Name t 4600 W Cypress St.Ste 200 Tar npe F 3607 ; _ Address city state Telephone Number at Designated Person: 813.574.5700_ _ Li a. In addition to Idmsal,the owner designates Ni/A of_ Z t- C-) Lil --ta receive a copy at the Llenats Native as provided in Section 713,13(1)(b),Florida Stanrtos. Ln LLt t-t- Q C�3 ` Telephone Number of Person or Emhq Designated by Owner: - -_ 0 Z � Q 9. Expiration data of Notice of Commencement is ao year from Ma date of recording unless a different date Is spedfled: F9 © 0 T W 1 p WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT � < 1CD Q F^ ul U Q ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1,SECTION Ti3.13 FLORIDA STATUTES, AND CAN Cr W - W RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICEr OF COMMENCEMENT MUST BE � 2 — CC RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT 0 q 1-. WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. W !i. LLI STATE OF FLORIDA T 0 QQ LL -J . COUNTY OF PINELLAS LU d Signal of Owner or 0era Arnhodzed Oificer/Diredodpartrer/Manager - xLJ Vice President V C) 'SignoWsTitie/Ofhce - ,rt; - €�7 _5 a it :5-- The foregoing instrument was acRnmvradged before me this t4 say of January by t V W 5 z Q 0 - Steve Robert Smith eo Vice President (type of cer.trustee,attorney In fact)for EY ti3 t s S G A Lennar Homes,LLC (name ally ur on b whom hrabumam was executed!. ZZY C�t t } � Persdne9y Known N 2a Produced Identification❑ Notary Signa �'_ U,Q C) `` Q LM, to F- Q ft) . Type or Identification Produced Name(Prim)_ I:Ii;sa Holleran � � Z LLI tt7 Q. -tLLJ W Verification pursuant to Section 92.525.Florida Statutes.Under penalties of pajury,I declare that i have read the foregoing and that the fads ataled in (,i) 5 It are true to the best of my knowledge and beget }® x of Z r- ELI93AN HOLLERIIN Signaturo of Natural Person Signing Above mce GmmbdaniFFOG5E37 FsFlns3cnrb,2020 wpdataibcsform: ipdMitaulny'fkhLocnoajamwn i "ASCO COUNTY, FLORIDA Permit No. _22S02 Date Permltted 2-Jq-2-C) Builder Name/Owner Name LKVVA-r I'tt1ti+� c—C, Control#' County Parcel No. 2.4-2,6-2� 61 10-6(Z,>(D-3l2o SubDiv: �t erL r r Z Address/Location 317 2 96d I D2 s Classificationlrype of Use ;x TRANSPORTATION IMPACT FEE Rate: S Ft Unit: t� Exempt' p ❑-A'es No How Determined {' Impact Fee Amount $. 3,�3a. Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ , 4 J(, 2-j3 (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [� Yes Q No How Determined PARKS AND RECREATION FEE: Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ v: Exempt ❑ Yes No How Determined �r- LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total s� Exempt ❑ Yes 0 No How Determined Total Amount _ RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE.ISSUED.OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Y Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a co of this form,placing k g PY P PY P pY g f the building permit owner,on notice of this assessment and the condlQons of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY 24-26.-21-0110-00000-3120 1 Pasco County Property Appraiser Page 1 of 1 Parcel ID 24-26-21-0110-00000-3120 (Card: 1 of 1) Classification 00000-Vacant � i Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,843 TAMPA , FL 33607-5995 Building $0 Extra Features $0 Physical Address 3172 LYTTON HALL DRIVE, ZEPHYRHILLS, FL 33540 Just Value $27,843 Assessed (Non-School Amendment 1) $27,843 Legal Description (First 200 characters) HIDDEN RIVER PHASE 2 PB 79 PG Non-School Taxable Value $27,843 102 LOT 312 School District Taxable Value $27,843 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) LineCode (Description J _Zoning Units _'Type—Price jConditionyal e 1 0100V ' LP1-1 SFR I MPUD 6,000.00 _ SF $4.50 1.00 $27,000 2 , 0100V LP1-2� SFR MPUD{ 937.00 SF $0.90 ' 1.00 $843 _ Additional Land Information _ Acres _ Tax Area FEMA Code Res Code _Com Cod_e _ Condo Code__ 0.16 30ZH -- I HDRV HDRV HDRV Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) Line Code Description Year Units No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC Month/Year_Book/Page T ype _iDORCode Condition Amount _ 01/2019 _ 9854 / 3547 j Warranty Deed 05 Vacant $4,965,000 09/2011 8606 / 3376 Warranty Deed 05 i`�— Vacant — $0 06/2010� 8360 / 1872 _ ' Certificate of Title lv 12 u Vacant -�-_ -( -- $0 - __12/2005 , 6748 / 0891 — i Warranty Deed I : Vacant $0 12/2005 6748 / 0889 _ Warranty Deed 1 _ Vacant $0 12/2005 ^j 6748 / 0894 j ` Warranty Deed j Vacant $0 https://search.pascopa.com/parcel.aspx?parcel=2126240110000003120 2/19/2020 • D Q' y' Single Family Dwelling Plan Review Comments 1. F.F.E:.shall be a minimum of 8"above the road elevation and an engineered site plan. 2. Lots sfiall.be graded to comply with.R401.3.of the F.B.C. 3. Compaction test required if 24. or more 0f fill.dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W.use permit: All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All,property markers shall be uncovered and marked at time:of first inspection.. 8: All A.D.A.'requirements shall be met: R. No electric,:plumbing; mechanical,or framing shall be covered without an inspection and approval first: 10: All Garages:shall comply with section R302:6 of the F.B:C. (Fire Separation): 11. Appliances shall not be installed in a location where subject.to mechanical damage unless protected by approved barriers. M303:4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3"above finished grade. M1308A . 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R3111 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C: 17. All means.of egress are to be in accordance with R311 of-the F.B.C. 18. "Greer'gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. . 10 Combination-type AFCI breakers are required at all locations requiririg an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage.''They shall be installed in accordance with the F.B.C. 21. All plumb ing,'mechanical; and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. I .23. Tamper-Resistant.Receptacles in accordance with 406.11 of the 2016 N.-E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25:.R403.5.3Hot water-pipe insulation. Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping 3h inch (1.9.1 mm)and larger in.nominal diameter. Piping serving more than:one dwelling unit. Piping located outside'the conditioned space. Piping from the water heater to a distribution manifold., Piping:located under a floor slab. Buried in piping, Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower.door test shall be provided before C,O: 26 A copy of the energy:cacls shall be with permit at all times 27. Copy of linaT insulation report-shall be provided with permit before rhzA 28:No fence,-pool onscreen enclosure 4&issued-with ahis_permit. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received FEB 0 3 VZO Phone Contact for Permitting 1� 813 363 2891 _1 I I I I I I I . . . I I . . . . . . . .L-A-11111 111 111111 1 1 1 1 a a m_1r_r. . . I-i�Ll Owner's Name Lennar Homes,LLC Owner Phone Number r8l3L574 5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A 172 Lytton Hall Drive JOB ADDRESS F LOT# 0312 SUBDIVISION Hidden River Phase PARCEL ID# 24-26-21-0110-00000-3120 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRR ADD/ALT SIGN Q DEMOLISH P INSTALL REPAIR PROPOSED USE SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME 0 STEEL DESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3044 SQ FOOTAGE2582 HEIGHT 12 Story -0BUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRICAL AMP SERVICE Flx_� PROGRESS ENERGY W.R.E.C. PLUMBING i$ MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do I I I .I I I I I I I 11-411i��I I I I I I I I Z BUILDER COMPANY I Lennar Homes,LLC 77� SIGNATURE REGISTERED Y/ N FEE CURREN Address 14600 W.Cypr Pt.Ste.J00 ampa,FL 33607 1 License# FZ7GCI518166 ELECTRICIAN COMPANY =Edmonson Electric, Inc. SIGNATURE REGISTERED I Y/ N J FEE CURREN L_]LLN_j Address I1034 Skipper Rrad,Tam 9aPL 33613 License# I EC1 3005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bay6net, F 4674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address P.O. Box 5308, Bayonet, FL 3X4-5308 License# I CAC058062 OTHER COMPANY 16—Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N I FEE CURREN I Y/N Address 4211 Shoal Line BIv pring Hill, FL 34607 License# 1 CCC057991 , , , i , It , , , i It , It It , r It It It , , , It It It It It It It It RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum,ten(10)working days aftef submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W-Petmit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . U. . . . . . . . . Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of.Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a ,.compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties; the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY-RESULT IN YOUR PAYING TWICE FOP,IMPROVEMENTS TO YOUR PROPERTY. IF YOW INTEND TO O TAIN FINANCING, CONSULT WITH YOUR LENDER R AN T RNEY BEFORE RECORDING YO TICE OF E E NT. FLORIDA JURAT(F.S 1 7. OWNER OR AGEN CONTRASim LTO Subscribed and sworn o d)Jfd Subscribed an sworn to(or affirmed)b re me this i4 arl-" by Ashlee Callahan 14-Jan-20 by Ashlee Callahan Who is/are personally known to me or Who is/are personally known to me or as identification. s identification. Notary Public ���"° Notary Public Commission No. FF985637 Commission No. FF985637 Elissa M.Holleran Elissa M.Holleran Name of Notary tvoed,printed or stamped Name of Notary typed,printed or stamped , ', Yt19SJ4N.II�IIIMN - I;LWJIN,NQLLEMN � �Rn��L'ani>tippGl��l� ,�� �;�ruru»niMPPBFC�l7 ,�i �R'ri�lufaM�,t4�4 �,1d41rJtryPof�t�an59�1tt�1l5artll „ ClSaid'9Sra�rw�tua;+5�19L�1lSnall PLOT PLAN NOT ASBOUNDARYKETCH ONLY SURVEY SEC. 24 TWP. 26 S, RNG 2.1 E. LOT 312 BEARING BASIS: HIDDEN RIVER, PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00-23-02" E PASCO ,COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: NOTES TAKE PREFERENCE, THIS PLAN IS FOR PERMITTING PURPOSES N I ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DATA SHOWN HEREON BASED ON THE ALL DIMENSIONS BEFORE ANY CONSTRUCTION, ENGINEERING PLANS OF KIMLEY—HORN AND ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. LEGEND: -NAA,— = PROPOSED DRAINAGE FLOW II i = 10' PUBLIC UTILITY EASEMENT (00.00) = PROPOSED GRADE E-00.00 = EXISTING GRADE ON LOT AREA CALCULATIONS NOTES: LOT =_A9q7_-O8SQ. FT. LIVING AREA =_Lqg�__SQ. FT. LOT GRADING TYPE = A ENTRY =_!!L_SQ. FT. PROPOSED PAD ELEVATION N/A GARAGE =A:L7---SQ. FT. FRONT SETBACK = 20' COVERED LANAI = N/A ---SQ. FT. SIDE SETBACK 10' PATIO, =23 —SQ. FT. REAR SETBACK = 10' CONC. DRIVE FT. A/C & CONC PAD = 1 B--SQ. FT. PRIVATE SIDEWALK FT. IMPERVIOUS = 29 ____7 2036 SQ. FT, SOD = 4901 --SQ. FT. OFF LOT AREA CALCULATIONS RIGHT OF WAY =_k90_-1_QSQ. FT. DRIVE APRON =_L4_4SQ. FT. PUBLIC,SIDEWALK FT. SOD = 317 --SQ. FT. TOTALS AREA =_76_300—0 —S Q. FT, DRIVEWAY FT. SIDEWALK =_L6_,3 _SQ. FT. SOD = 5218 --SQ. FT. LOT 313 00, 76'28%d 4� ...... 110.00, .......... LOT 288 j -38.00, � 147.83............ 4L w?.— 23 ..... ...... }/ !1 a tr� LOT 312 3800, C nJ 0 _j LOT 289 cy ........ S 5.00. 4.0 IJQ a 00, 4.0 .00' LOT 311 _f DETAIL N.T.S. LOT 290 n DESCRIPTION: PROPOSED: 4 f LOT 312, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", LOWEST FLOOR ELEVATIONS: AS RECORDED IN PLAT BOOK 079, PAGES 110 THROUGH LIVING AREA: 72.45' 082, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A V ELEVATIONS REFERENCED TO I CURVE I RADIUS I ARC I CHORD I BEARING I DELTA NATIONAL GEODETIC VERTICAL C212 1 780.00- 1 67.85' 1 67.83- 1 S 16-00-46- W I W.59-02", C239 670.00' 35.48' 1 35.48- 1 N 2901*19- E 03. 2F4" _ DATUM OF 1929. MEAN SEA C240 1 670.00' 1 58.28' 1 58.26' 1 N 15-00-46- E 1 04- 9'02- LEVEL= 00.00 FT. C APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 12101CO458F EFFECTIVE DATE: 09 26/2014 Square Feet: 6937.08 t LENNAR HOMES LEGEND: ID(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED,`E/P—_EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD,* FM&D- FOUND-NAIL & DISK, FPP- FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.— MASONRY, OR— OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP- PERM-ANENT CONTROL'POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D=,SET-NAiL.&_bISK No.4493, TBM= TEMPORARY BENCHM6RK. U/P= UTILITY POLE, W/F= WOOD FENCE JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS SURVEYORS AND MAPPERS Checked By: t 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (B1 3) 854-1276 FAX (813) 855-8370 Scale: 1"=30, NOT VALID WITHOUT ORIGINAL SIGNATURE jDate: PLOT PLAN 01/09/2020 RTM_ AND SEAL OF A FLORIDA LICENSED SI A _�E E f IF IN R E� SURVEYOR AND MAPPER R. EACH FLORIDA D� i Revisions; F RIDA LAND SURVEYOR No. 2984 T LB#4493 JEFF M. HAVLEY PROFESSIqWL SURVEYOR'& MAPPER No.7123 ,f C40 t r _�P,4 un cjr ZY OD CO co 01 Pq 1 1 I 1 ri K,y�,yy va j,�� '�.�, Y� ,�'( t71 tom' J� �� ,� � ..� � -""'.�"�,......,,,,. ���'"�.."-"-•--.....;. -,.,..... i f �'�- --......,�q����i s 1 %�