Loading...
HomeMy WebLinkAbout20-22503 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22503 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION,. Permit#:22503 Issued: 2/21/2020 Address: 3160 LYTTON HALL DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est.Value: Book: Page: Cost: 226,201.20 Total Fees: 18,777.47 Subdivision: HIDDEN RIVER Amount Paid: 18,777.47 Date Paid: 2/21/2020 Parcel Number: 24-26-21-0110-00000-3110 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,008 SQ FT APPLICATION FEES PLUMBING FEE 176.25 SEWER CONNECTION RESIDENT. 2,090.00 ELECTRICAL FEE 264.38 WATER CONNECTION RESIDENT 1,010.00 MECHANICAL FEE 123.38 SCHOOL IMPACT FEE-sfr/1% 83.28 SCHOOL IMPACT FEE-sfr/100% 8,328.00 TRAFFIC IMPACT FEE 1% .36:32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,273.49 PARK FEES SF 769.56 PUBLIC SAFETY 5% 26.35 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 WATER METER RES 3/4" 473.78 Inspections Required FOOTER 2ND R UGH PLUMB MISG INSUI ATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. Njj 0 R lj�� &__ 6"407 ' )r'CONTkA6TbM SIGNATURE I PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER i I Lennar Homes-3160 Lytton Hall Dr.2,008 sqft Column SQ. FEET PRICE MAIN OR LIVING: 2,008 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 226,201.20 FEE SHEET $ 1,175.00 ADDRESS $ 30.00 DRIVEWAY1 $ 45.00 BUILDING: $ 1,273.50 ELECTRICAL: $ 264.38 PLUMBING: $ 176.25 MECHANICAL: $ 123.38 SUB-TOTAL $ 1,837.50 TOTAL $ 1,837.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - '24 FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL 1 TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,964.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 8,328.00 100.0% $ 8,328.00 1.0% $ 83.28 { TOTAL: $ 8,411.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 i TOTAL: $ 18,777.47 4 � t Single Family Dwelling Plan Review Comments 1. F.F.E; shall be a minimum of 8" above the road elevation and an engineered site plan. 2: Lots shall be,graded to comply with R401:3 of the F.B.C.- Compaction test required if 24"or more of fill dirt is brought in at any one place. 4. Tie in survey,required before pouring concrete. 5: Driveways require a R.O.M.use permit. All 4 sides of driveway thru,the sidewalk shall have expansion material. 6: All setbacks shall be met. 7. All property markers shall be uncovered.and marked at time:of first inspection. 8: All A.D.A. requirements shall be met. p g; , . . g 'without an inspection and 9, No electric , lumbin mechancal or framin shall be:covered approval first. 10. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation): 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303:4 of the F.B.0 12.'Water heaters-shall.comply with section P607.3 of the F.B.-C. 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308.:1 . 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke.detectors are to be installed in accordance with.R3.13:1 of the,F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F:B:C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs.R702.4 2 RB:C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will:be required in new construction that-uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. M All 2016 N.E.C. Codes will be enforced: I i 4 i f 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C .24. In accordance with the Land Development Code,lots.shall be sodded before finial at least 10. feet around the structure. .25-. R403.5.3Hot*aterpipe insulation Insulation for hot water pipe with'a minimum thermal resistance (R-value) of.R-3 shall.be applied to the following: Piping.3h inch (19.1 mm)and larger in.nominal diameter.. Piping,serving more than one dwelling unit. piping located outside the conditioned space: Piping from the water'heater to a distribution manifold:, Piping:located under.a floor slab: Buried in piping.. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower.door'test shall be provided before C.O. . 26.A copy of the enemy=cacls-shall be with-permit at all.di`nes 27. Copu of final-insulation report-shaff be provided with Permit before final 28 No fence,pool or enclosure :is-issued.with:thispermit. F.F.E.-Finished Floor Elevation F.B.C-:Florida Building Code 6ffi Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act: N.E.C.-National Electnc'Code (2016) i { W. PASCO COUNTY, FLORIDA - Permit No. ZZcsh�3 Data Permitted Builder Name/Owner Name L&4Jw- &yw! L(,e— Control# l County Parcel No. 2 -4_Z/_61f -606W—3 j1a SubDiv: ddiim 4 1 v _ c• Address/Location y069>., /`4 / OIL ClassfffcatioM'ype of Us@ TRANSPORTATION IMPACT FEE Rate: Sq.Ft UnIV i Exempt ❑ 'es ❑ No How Determined Impact Fee Amount $$. 3�,1Q Zone No. TAZ: r�. SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ IN,, zH (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [�Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 70��{ Y; Exempt ❑Yes ❑ No How Determined qi i i:�• I LIBRARY FEE K Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount_ RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND t< RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of•a copy of this form,placing F• the bullding permit owner on notice of thls assessment.and the condlUons of payment for same. i f DATE RECEIVED BY RECEIPT NO. DATE BY - 24-26-21-0110-00000-3110 1 Pasco County Property Appraiser Page 1 of 1 I Parcel ID 24-26-21-0110-00000-3110 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,947 TAMPA , FL 33607-5995 Building $0 Extra Features $0 I Physical Address 3160 LYTTON HALL DRIVE, ZEPHYRHILLS, FL 33540 )ust Value $27,947 Assessed (Non-School Amendment 1) $27,947 Legal Description (First 200 characters) HIDDEN RIVER PHASE 2 PB 79 PG Non-School Taxable Value $27,941 102 LOT 311 School District Taxable Value $27,947 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) _ Line Use ICode IDescription Zoning!Umts Type jPrice Condition Value _ 1 0100V LP1-1 SFR -^ MPUD 6,000.00 SF 4.50 1.00 $27,000 2 1 0100V LP1-2 - SFR MPUD 1,052.00 ( SF 1 $0.90 1.00 $947 Additional Land_ m Code Information _ -� —�� FEMA Code T Res Code Co Acres Tax Area J Condo Code 0.16 30ZH -- ( HDRV I HDRV 14 HDRV Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) Line Code Description -- —�— Year iUnits -- IV lua a -- No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC Month/Year ;Book/Page _ pe� u`DOR Code Condition Amount _— 01/2019 _ ' 9854 / 3547 Warranty Deed ¢-� -- -_ �— -�--^05 -�1- Vacant $4,965,000 - 09/2011 - - 8606 / 3376-._ _ Warranty_Deed 05 Vacant _ $0-_ 06/2010 j 8360 / 1872 ! Certificate of Titled- 12 _ Vacant $0 __— 12/2005 1 6748 / 0889 - 1T_Warranty Deed I _ _-Vacant $0 12/2005 ! 6748 / 0894 Warranty Deed _- Vacant $0 12/2005 1 6748 / 0891 Warranty Deed T _ , Vacant ; $0 i I� i I https:Hsearch.pascopa.com/parcel.aspx?parcel=2126240110000003110 2/19/2020 )NSTR#2020030143 OR BK 10056 PG 2854 Page 1 of 1 02/20/2020 11:56 AM Rcpt,2137341 Ree:10.D0 DS:0.0D IT:D.DD Nikki Alvarez Sowles,Esq.,Pasco County Clerk&Comptroller Pcr ftNo, ParcellDNo 24-26.21-0110-00000-3110 -- - NOTICE OF COMMENCEMENT state of Florida. County or.- Pasco _. THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following Information Is provided In We Nagee of Commencement 1. Oescdption of Property,Legal HDDEN RIVER PHASE 2 PS 79 PGS 1112-110 LOT 311 sbeetAddress::3160 Whan Hall Drive zaphryhius FL 33541 2. General oesaipilon of Improvement Single Family Residence 1 Pool 1 Screen Enclosure/Fence 3. Owner Information Lenner Homes,LLC. _ Name - 4600 W Cypress St.Ste,200 Tampa FL 33607 Address City -- -- State Interest in Property: Name at Fee Simple Titleholder. N/A - (If other than owner) - - - - Address - City Sate q. Contractor. Lennar Homes LLC _ _ _. ')."�, •'��. { Noma 4800 W Cypress Sty Ste 200. - Tampa F1�33607 Address City= - - State Gontradots Telephone No.: 813.674.5700. r ti r N/A Name - - .- , .ylr•' ..... uu;3r ST cy r T / Address -Cris state Amount of Bond:S•- Telephone No.: S. Lender. NIA Name , • Address' city Stale Lendets Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 71a'13(1)(e)(7),Florida Slalutes: ; Name " 4600 W Cvoress St Ste 20D Tampa FLy33607 Address '" - CRY State Telephone Number of Designated Person: 813.574,6700 W a. Ina OO=to himself,the owner designates N/A of� Q Z C�j � � J to receive a copy of the Lianor's Notice as provided In Sudan 713.13(1)(b),Florida Statutes, (n U J U_ r� Ix C� Telephone Number of Person or Entity Designated by Owner. F- O. H 0. Expiratlon date of Notice of Commencement is one year from the date of recording unless a different date Is spedfled: C1 O0 < � 0. WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT W 5 h- � (5 p ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAP7ER713, PART1,SECTION71313 FLORIDA STATUTES AND CAN , RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A N069 OF COMMENCEMENT MUST BE tY W RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT Li. O 2: Q MATH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WOW(OR RECORDING YOUR NOTICE OF COMMENCEMENT. �LF" L L F- LL STATE OF FLORIDA Lam, � LLL .J•r . C) COUNTY OF PlNt3 LA5 Srena ure afo.,.t-ownais AuOonzad Officer/DiradoriPaMermJaneger Vice President 2 U Q Signatory'sTtdelOffw !— I_ J } ` The foregoing Instrument was acknowledged before me this 14 day of Jenueiy - .by Ci _ LU -J ?CL t� Steve.Robert Smith as Vice President (type of a- `' _ .,officer,trustee,attorney In fact)for L�' 0. `� � CC0. LL. � d i� Leririat Homes..LLC - (name o'arty o wham tnamrmantwas axextiett). •� OU O }_ n Personally Known X OR Produced Identification❑ Notary Signal- - Type oftdentlficationProduced Name(Print) Ellssa 011eran Cn ¢ W w UJI Verificatfan purouent to Sermon 02.525,Florida Stables. Under penallies of perjury,I declare that 1 hate reed the foregoing and mat rho fads stated'm � Lr) � I,L g are true to the best of my knowledge and beget V FF--- HOB' e EfIS4A)F HOttEA{F! S g Sure of Natural Person Signing Above t `acmes anIFFgtLW ErFlta,pilseg2g2g wpdataPocsibcs form: EoddThnrTmhttlsararatdadtS71� 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received FEB 0 3 2020 Phone Contact for Permitting 813 363 2891 I JL_J Owner's Name Lennar Homes,LLC Owner Phone Number r811�5745700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 3160 Lytton Hall Drive F LOT# 0311 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-3110 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONITR R ADDIALT SIGN Q DEMOLISH P INSTALL REPAIR PROPOSED USE 0 SFR F__1 COMM OTHER TYPE OF CONSTRUCTION 10 BLOCK Q FRAME 0 STEEL DESCRIPTION OF WORK Single Family Residence 1 Pool/Screen Enclosure/Fence BUILDING SIZE [ U/R SF 2008 SCI FOOTAGE 1 1555 HEIGHT 1 Story BUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRICAL 1$ AMP SERVICE FX_1 PROGRESS ENERGY W.R.E.C. OPLUMBING $ MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS I/1 ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do sismai . . . . . . . . . . . . BUILDER COMPANY I Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cyp&s t.Ste.200,T License lafl$a,FL 33607 CGC1518166 I I ELECTRICIAN COMPANY I Edmonson Electric, Inc. SIGNATURE F REGISTERED Y/ N FEE CURREN Address 1034 Skipper lad, Tapqw, FL 33613 License# [EC13005408 PLUMBER COMPANY I Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 53 ay FL 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 53Jkay9netX, 34674-5308 License# I CAC058062 OTHER V ot COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal L' e lvd, Spring Hill, FL 34607 License# 1 CCC057991 IIIIIIIIIIIrIII 1 rlrrrlrllllll111111 lllllllllllllillilrllilliililt RESIDENTIAL Attach(2)Plotb6ps;(2)Sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal bmittal date. Required onsite,Construction Plans'i.Stormwater Plans w/Silt Fence"installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W,Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . ... . . . . . . . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no'work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEN TOO AIN FINANCING, CONSULT WITH YOUR LENDER OR AN-ATT.OEZNEY BEFORE RECORDING-YOUR- - -OF ZOMENCEMENT. FLORIDA JURAT(F.S. 7.0 ) OWNER OR AGEN X11 CONTRACTOR Subscribed and sw a irme a ore me this Subscribed a s or a firm be ore me this II+-Jan-/_u by Ashlee Callahan 14-Jan-20 by Ashlee Callahan Who is/are personally known to me or Who is/are personally known to me or as ide 'ication. as identification. Notary Public Notary Public Commission No. FF985637 Commission No. FF985637 Elissa M.Holleran Elissa M.Holleran Name of Notary tvoed,printed or stamped Name of Notary typed,printed or stamped �1;19SJ1N.P(�Ll�4AN '� „�ertm�L'�null'PoWel7 � :,�Ir�rwLanidf'PGbSBt� � ,e�E��j,tut:��,2Cx0 Fk4a�ur��,�G10 �.,idn�csy�.,tvR��lltaiSdGll �,idh�r,9rylr+t�tvs���!!tal�1411 SKETCH ONLY SEC. 24 TW P. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 311 BEARING BASIS: HIDDEN 'RfVER PHASE 2 WEST BOUNDARY OF SUBJECT- - PLAT BEING N 00*23'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES ONLY, NOT FOR CONSTRUCTION, VERIFY ALL DATA SHOWN HEREON BASED ON THE ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENGINEERING PLANS OF KIMLEY—HORN AND ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. LEGEND: PROPOSED DRAINAGE FLOW 10' PUBLIC UTILITY EASEMENT (00.00) = PROPOSED GRADE II E-00.00 = EXISTING GRADE ON LOT AREA CALCULATIONS NOTES: LOT = 7051-96SQ. FT. LIVING AREA =__15_56___SQ. FT. LOT GRADING TYPE = A Ent ENTRY = 45 —SQ. FT. PROPOSED PAD ELEVATION = N/A GARAGE =__±0_6SQ. FT. FRONT SETBACK = 20' COVERED LANAI FT. SIDE SETBACK = 10' PATIO, =--13—SQ. FT. REAR SETBACK = 10' CONC: DRIVE =___!L5_1SQ. FT. A/C & CONC PAD 9 --SQ. FT. PRIVATE SIDEWALK = 28 —SQ. FT. IMPERVIOUS 36 _% 25_1.8__SQ. FT. SOD =--15-34SQ. FT. OFF LOT AREA CALCULATIONS RIGHT OF WAY =_7_0_3A_SQ. FT. DRIVE APRON =___14_4SQ. FT. PUBLIC SIDEWALK =__25_7._SQ. FT. SOD _3_68 __SQ. FT. TOTALS AREA —2-821-30 SO. FT. DRIVEWAY 595 —SQ. FT. ,44j LOT 312 SIDEWALK _285— Q. FT. SOD 4902 —SO. FT. S �129, c� _j 170.00, Iq 46�00 LOT 289 68- 0. 41�_' / �ro , o«. 0 v) / / t� rV 54, 54.00, S 1-29' LOT 290 4:At 66, W CO• 00' LOT 310 LOT 291 DESCRIPTION: n 4 LOT 311, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", PROPOSED: AS RECORDED IN PLAT BOOK 079, PAGES 110 THROUGH LOWEST FLOOR ELEVATIONS: D 082, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LIVING AREA: 72.15' GARAGE AREA: N/A CURVE RADIUS ARC CHORD BEARING DELTA ELEVATIONS REFERENCED TO 4 1 C?13 1 780.001- 41.31 41.30' 20*0i'lg" W 03*02'04" 1 NATIONAL GEODETIC VERTICAL In I C21 6 1 430.00' 22.80' 22.79' S 20*01'13" W OXOT_1_9�_ 75 C238 540.00' 1 28.63� 1 28,62' N 2FO—V 1-3-7_E -6-3 02'1�5 DATUM OF 1929. MEAN SEA V, _5'C239 1 570.00' 1 35.48' 1 35.48' N 20'01'19" E 30204— LEVEL= 00.00 FT. L APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 12101CO458F EFFECTIVE DATE: 09/26/2014 ISquare Feet: 7051.96 f =LENNAR HOMES LEGEND: 5(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C=,AIR'CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED,,E/P' EDGE.OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D- FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE- LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT�BOOK, PCP- RERWANEN T CONTROL POINT, PRM- PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493,'SN&'D*-- SET-NAIL DISK No.4493, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE Drawn By: 5 JOHN R.BEACH&ASSOCIATES,INC. SMS 2 SURVEYORS AND MAPPERS Checked By: t 911 WEST ST. PETERSBURG DRIVE ONE JRB OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Sc1a"=le: e2 NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 01/09/2020 RTM 3 A E UfE AND SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER OFN R. EACH S 'Revisions: FLORI\DAR .-.LAND SURVEYOR"No. 2984 LB#4493 _jEFF M. HAqLEY PROFESSIC-NOL SURVEYOR& MAPPER No.7123