Loading...
HomeMy WebLinkAbout20-22506 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22506 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:22506 Issued: 2/21/2020 Address: 3125 NUBBIN RIDGE LN Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: 'Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 226,201.20 Total Fees: 18,777.47 Subdivision: HIDDEN RIVER Amount Paid: 18,777.47 Date Paid: 2/21/2020 Parcel Number: 24-26-21-0110-00000-2890 CONTRACTOR INFORMATION OWNER'INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,008 SQ FT APPLICATION FEES PLUMBING FEE 176.25 SEWER CONNECTION RE IDEW 2,090.00 ELECTRICAL FEE 264.38 WATER CONNECTION RESIDENT 1,010.00 MECHANICAL FEE 123.38 SCHOOL IMPACT FEE-sfr/1% 83.28 SCHOOL IMPACT FEE-sfr/100% 8,328.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,273.49 PARK FEES SF 769.56 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 WATER METER RES 3/4" 473.78 Inspections Required FOOTER 2ND ROU H PLUMB MI INSUI ATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. t77 , __ 6�1,9- CTO 1 IrSSIGNA URE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INsTw2020030137 ORBK 10056 PG2848 Page 1 6f1 02I20/2020 11:56 AM Rcpt 2137341 Rec:10.00 DS:0.00 IT:0.00 Nikki AftrezSowtes:Eso:.Pasco GountX Mork&Comptroller _ i I I ParmIt No. -- Pareal ID No,24-25-21-0110-00000-2840 NOTICE OF COMMENCEMENT State of Flodda County of Pasco i THE UNDERSIGNED hereby ghres notice that improvement will be made to certain reel property,and in accordance with Chapter 713,Florida Statutes, the following hformation Is provided In this Notice of Commencement: 1. Desa"m of Property.Legal HIDDEN RIVER PHASE 2 PS 79 PGS 102-110 LOT 289 -- streetAddreas:_3125 Nubbin Ridge Lane Zephryhills FL 33541 2 Ga met D=rolion of bnpn vemerd Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: -LennarHomes,LLC. — - -Namet; - - -- - - - 4600:W Gyoress Sa,,Ste 200 7a a- F�,3�607 -Atldresa city - State Interest in Property: Name of Fee Simple TWahotder. N/A (N olherthan owner) ¢, • ,- fl Address - - City State • ` ,`b. ♦, Contractor. Lennar Homes,LLC ag 4600 W GYP ass it,Ste 200 Temila FL.,33607 tic Address CRY State - Mv, y...;1tiR�/�;.: `' + j s•,' Contractors Tete orre No: 813.574.5700 6. surely N/A , Cty°$ �• Name - Address - - City Amount atBond:S- Telephone No.: 6. Lender N/A Noma Address City state Lenders Telephone No.: - 7. Persons within the State of Florida designated by the owner upon Whom notices or other decuments may be served as provided by Section 713.13(1)(a)(7),Fiodda Sintu tak Lettn r Homes LLC: u: Name - - - LLI J W 4 4600 W Cypress St Ste 200 Tampa . _ FLU 33607 d �? 01 j W Address City - - State t!1 UJ U- (� � V 'r Telephone Number of Designated Person: 813.574.5700 _ :a U- aI } r C) Z -a 8. In addition to himseR,the owner deli ales-N/A of (� u5C) 1 O W(_l to receive a copy of the Liences Notice as provided in Section 713.13(1)(b),Florida Statutes, $ � F... („) Telephone NumbertrfPersanOrEnthrDesignatedbyOwner - I LIJ Z J rt3' LL Q 0. Exptration date of Notice of Commencement Is one year from the date of recording unless a different date Is specified: 0 Ll- WARNING TO OWN ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT � �Q ER: C} ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES. AND CAN LL- Ur RESULT IN YOUR PAYING VAICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE }- L1J d _ RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION: IF YOU INTEND TO OBTAIN FINANCING,CONSULT )— o- IY p tf7' WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR REC NG YOUR NOTICE OF COMMENCEMENT. b �! J STATE OF FLORIDA ^COUNTY OF OF PINEIlAS ./--'� [.'o 0 Lt.a . Signature of Owner or Owners Authorized Otficer/DlrectorrPadnerlMonager �_ d Q O Via president M 0 U- t` SlgnatorysTltleJQfgce" - � Q u ` a ' The foregoing Instrument was acknowledgod before me this day of January, by O 0 0 ! 7 Sieve Robert Smith as Via President {type of authority,e.g.officer,trustee,aftomey in fad)for r- < LLI _j Q i DJU; d -ULU Lennar Haines LLC {name of p a o ritnstrument was comarted). I- W - Personally Known j#03 Produced Identificat on❑ Notary Sig - _ cc F� >" Type of Identification Produced Name(Prod) Issa olieian F- Vedficatlon pursuant to Section 92.525,Florida Statutes. Under penalties of pej ai I have read the foregoing and that the facia staled in It are true to the best of my knowledge and belief. , &3s3RM HGttERAtt Signature of Noticed Person Stating Above GtrmilliknfFFQi6&1T - E111LndmteR,2D2D wpdata/bceibcs farm: Ismial laoTrryFahuWvvn.r WWlfdptt I . i Lennar Homes-3125 Nubbin Ridge Lane-2,008 sgft Column SQ. FEET PRICE MAIN OR LIVING: 2,008 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 226,201.20 FEE SHEET $ 1,175.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,273.50 ELECTRICAL: $ 264.38 PLUMBING: $ 176.25 MECHANICAL: $ 123.38 SUB-TOTAL $ 1,837.50 TOTAL $ 1,837.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,964.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 8,328.00 100.0% $ 8,328.00 1.0% $ 83.28 TOTAL: $ 8,411.28 I T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,777.47 PASCO COUNTY, FLORIDA I -- - - Permit No. Sb" Date Permitted -Builder Name/Owner Name !-.G Aew- 4mez'­ A& Control#' " County Parcel No. 2.q 74-2- ,Vt0-660C0-26bSubDiv: AddresslLocatlon c3'12� u✓�� �C ,� Classificatlon/Type of Us@ TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2/Lbg �n f Exempt ❑Ves ❑ No How Determined Impact Fee Amount $. 31632,Z Zone No. TAZ: SCHOOL IMPACT FEE e> Account (056) Single-Family R6tached House Amount $ _19, 2,f5 r. . (057) Mobile Home (058) Other Residential 123)' Collection Fee Exempt [�] Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7 . r. Exempt ❑ Yes ❑ No How Determined LIBRARY FEE "- Land Account Land Credit Land Total E P. Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount _ RESOURCE FEE ERU TOTAL AMOUNT Prepared By r Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL.INSPECTION PERFORMED UNTIL.TAE TOTAL AMOUNTS LISTED HAVE BEEN PAID-AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY F; y. Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment'and the conditions of.payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 24-26-21-0110-00000-2890 1 Pasco County Property Appraiser Page 1 of 1 Parcel ID 24-26-21-0110-00000-2890 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,841 TAMPA , FL 33607-5995 Building $0 Extra Features $0 Physical Address 3125 NUBBIN RIDGE LANE, ZEPHYRHILLS, FL 33540 Just Value $27,841 Assessed (Non-School Amendment 1) $27,841 Legal Description (First 200 characters) HIDDEN RIVER PHASE 2 PB 79 PG Non-School Taxable Value $27,841 102 LOT 289 School District Taxable Value $27,841 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) Line Use_ _Code - Description _ _Zoning,Units -Type - Price Tlcondition;Value _ 1 I 0100V_1 LP1-1 _ SFR MPUD 6,000.00 _ SF $4.50 1.00--- $27,000 2 1 0100V I LP1-2 — SFR MPUD 934.00 } SF -� $0.90 1.00 1 $841 Additional Land Information _ _ Acres _Tax Area FEMA Code_ Res Code _ Com Code _ Condo Code 0.16 -30ZH -- HDRV j HDRV - HDRV Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) _ Line ;Cody- a --Description_ Year Units- _ -�- �Value ` �No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC M_ onth/Year Book Page _ IType _ DOR Code__ Condition_!Amount _01/2019 - 9854 / 3547 _j Warranty Deed �_ 05 - Vacant $4,965,000 09/2011 _ 8606 / 3376 Warranty Deed j 05 _ Vacant $0 06/2010`—I- 8360 / 1872 1 Certificate of Title_ 12 -�� Vacant $0 12/2005 6748 / 0894 j Warranty Deed i Vacant $0 12/2005 6748 / 0891 Warranty Deed 1 _Vacant $0 12/2005 6748 / 0889 Warrant Deed — __Vacant 1 $0 https://search.pascopa.com/parcel.aspx?parcel=2126240110000002890 2/19/2020 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 2891 LLC 00 Lermar Homes, Owner's Name . . . . . . . Owner Phone Number 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner's Address Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS [3125 Nubbin Ridge Lane LOT# 0289 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-2890 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR8 ADD/ALT SIGN DEMOLISH P INSTALL REPAIR PROPOSED USE u r u SFR Q COMM OTHER TYPE OF CONSTRUCTION u v u BLOCK E:] FRAME STEEL DESCRIPTION OF WORK SingleFamily Residence Pool/Screen Enclosure Fence BUILDING SIZE I U/R SF 20 SQ FOOTAGE1555 HEIGHT 1 Story -101BUILDING . . . . . . . . . . . $qi a I qq VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE F'X_1 PROGRESS ENERGY Q W.R.E.C. i .OPLUMBING MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS F4 ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do 114 11 1 1 111 16-41.4-16-41.1 1 1 1 1 1 1 1 1 1 1 11-4-4-11 164-1-4-54-4-11— BUILDER COMPANY Lermar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN A Address 4600 W.Cypress St.Ste.2/,Tampa,FL 33607 License# CqC1518166 ELECTRICIAN COMPANY Edmonson Electric,',Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 11034 Skipper Road,Tampff, FL 3361, License# I E6 13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, lnc7 SIGNATURE REGISTERED Y1 N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL f4674-5 8 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674- , 308 License# I CAC058062 OTHER COMPANY C=Sterfing Quality Roofing, oofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN EY/N Address 4211 Shoal Line Blvd, Spring III, FL 34607 License# F�7QC70757991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster;Site Work rk Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus 6 Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I clumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from ownertalutho(izing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired-a contractor or contractors to undertake work, lthey may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Blodk" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood-that Transportation Impact Fees and Resource Recovery Fees must be paid prior to - receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certifylthat I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City!codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to: be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LEND AR OR AN ATTORNEY BEFORE RECORDING YOUR ICE OF OOMMENCEMENT. FLORIDA JURAT(F.S. 7.03 OWNER OR AGEN CONTRALTO — - -- - -Subscribed-and swor t (o ffirmed) is Subscribed and swo n r a irme be ore me this LL-Jd(1-LU by Ashlee Callahan zz-Jan-zo by Ashlee Callahan Who is/are personally known to me or Who is/are personally known to me or as identification. as identification. Notary Public Notary Public Commission No. FF985637 Commission No. FF985637 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ... OP:l luEl 4", �rrm'k�ronu�pPae�ntr ` �2nY�,bnuitF°gDd�BT � 7 idiSra:agli+trurn� imp nil �nid�Y:�'rayPatrt+a� ��14t ►1 i © j Q r 0 Single Family Dwelling Plan Review Comments 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill_dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be-met. -7. All.property markers shall be uncovered and.marked at time.of first-inspection. 8: All A.D.A.requirements shall be met: 9. No electric,plumbing,mechanical, or framing shall be:covered without an inspection.and approval first: 10. All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation): 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303;4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B:C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1-308:1- . W. Return air in all bedrooms. F.B.C. M1620.4 1-5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the RB:C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs.R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AM type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all: underground plumbing and electric. 21 All 2016 N.E.C. Codes will be enforced. ` I 23. Tamier- Resistant.Receptacles in accordance with 406.11 of the 20161N.E:C 24. In accordance with the Land Develop_merit Code,lots shall be sodded before final at least 10 feet around the structure. 25. R403.5.3Hot.water pipe insulation Insulation for hot.water pipe Withh-a minimum thermal resistance (R-value) of.R-3 shall be applied to the following*:' Piping�1.inch (19.1 mm)and larger in:nominal diameter.. Piping.serving more than one dwelling unit. Piping located outside the conditioned space:. Pipingf theer heater to.a'distribution manifoldmwa , Piping.located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O: 26.A copy of the' energy cacls shall be with permit at all times 27. Copu of Thal insulation report shall be provided with permit before linab 28. No fence,pool or enclosure :is issued with:this-permit T.F.E.-Finished Floor Elevation F.B.C-:Florida Building Code 6 h Edition R.O.W.-Right of Way A.D:A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) 1 FF EL Z l4 W-A: _ ti4 EK 316 , ® ® e 285 �= � - - - - - .. ® , FF EL t 3 73.20 f : FF EL J �� E 273 r .. 73.35 i 1~ A 3 15 286FF EL ,a 73.50 r FF EL j P F F EL` r t� L' 1 4 73.40 272 + 1 73. 5 J `sue. .1 ;d 5 } � � •' Z FEL 4.00 x OFF EL FF EL ' '� '; I r � �. ; 73.7q 7'' J 2.75 313 2pFF EL FF EL 1 ` ( , �'' 74.35 � t 74.00 r� 72.45 B 279 f 1312 I FF ELFF E - � '�- 74.35 72.15 7 s � B 269 SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 289 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00-23'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES ONLY, NOT FOR CONSTRUCTION, VERIFY ALL,DATA SHOWN HEREON BASED ON THE ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENGINEERING PLANS OF KIMLEY-HORN AND ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. LEGEND: --4w— = PROPOSED DRAINAGE FLOW rt = 10' PUBLIC UTILITY EASEMENT (00,00) = PROPOSED GRADE ii E-00.00 = EXISTING GRADE NOTES: a LOT GRADING TYPE = A PROPOSED PAD ELEVATION N/A En FRONT SETBACK = 20' t SIDE SETBACK = 10' REAR SETBACK = 10' LOT 313 LOT 288 S :75'49'14,, ....... go 110.0(), LOT 312 52' 46.00, C, 01 C)V . ......... OZ- C) ry C� 37.0 CIV ................... ...... ..... . S 8&24- 5" E .... 8.00, 2�07,31 54- o> • 1 . 0 LOT 311 7j9,29., /V 20.5 29 :- : ,- ..0,, ON LOT AREA CALCULAIO TNS LOT =-6-913—.79 SQ. FT. j 7 LIVING AREA =- SO. FT. 0.0 -j%& 01 — ENTRY FT. GARAGE =-AO-6--SQ. FT. COVERED LANAI =-BZA---SQ. FT. LOT 290 C� /`4 PATIO =-.2-3---SQ. FT. CONC. DRIVE =--!L59--SQ. FT. cp 6 A/C & CONC PAD =-2--SQ. FT. PRIVATE SIDEWALK 28--SQ. FT. IMPERVIOUS 36---% 01. 2526.--SQ. FT. SOD =--LA-0--SQ. FT. OFF LOT AREA CALCULATIONS RIGHT OF WAY FT, DRIVE APRON =--144---SQ. FT. PUBLIC SIDEWALK =--2-69----SQ. FT. SOD =--N9.--SQ. FT. S TOTALS AREA 7741ACA-SO. FT. DRIVEWAY FT. SIDEWALK = 97 SO. FT. SOD =--IBQZ--SQ. FT. C> PROPOSED: rn DESCRIPTION: aLOWEST FLOOR ELEVATIONS: LOT 289, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", ' 0 AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH LIVING AREA: 74.65 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A ELEVATIONS REFERENCED TO 0� CURVE RADIUS ARC I CHORD BEARING DELTA NATIONAL GEODETIC VERTICAL CIg 890!00:0�� 1 47.13- 1 S 20;01,19" W 1 03 2-04" 1 00 1 47,114� 1 DATUM OF 1929. MEAN SEA 67� 9' 67.17 S 1620'31" W 1 0 9;,31 C211 750.00' 58.88' 1 58.87' N 16-20-31- E 04! 9 31 LEVEL= 00.00 FT. uti APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101 C0458F EFFECTIVE DATE: 09/26/2014 =q..,. Feet: 693179 LENNAR HOMES LEGEND: z w (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= a CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, Y F/C- FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP- FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D- FOUND NAIL & DISK, FPP= FOUND PI�NCHED6 K PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK,,POP= PERMANENT CONTROL POINT, PRM= PERMANENT 5j REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK No.4493, TBM= TEMPORARY BEUCHMARK. ULP= UTILITY POLE, W/F= WOOD FENCE Drawn By: JOHN R.BEACH&ASSOCIATES,INC. Sms aZ SURVEYORS AND MAPPERS t 911 WEST ST. PETERSBURG DRIVE Checked By: ONE JRB "0 OLDSMAR, FLORIDA 34677 - :9 WAY (813) 854-1276 FAX (813) 855-8370 Scale; 1 1"=30' NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 01/31/2020 RTM AND SEAL OF A FLORIDA LICENSED GNA E DATE SURVEYOR AND MAPPER R. ORNIDR JO.o Revisions: Fl- A-RE& ?-Mr,"SURVEYOR-No. 2984 LB#4493 J J EFF M.�HA AL- SURVEYOR SI[-EY'O' k & MAPPER No.7123