HomeMy WebLinkAbout20-22533 CITY OF ZEPHYRHILLS
5335-8th Street
(813)780-0020 22533
ELECTRICAL PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit#:22533 Issued: 2/28/2020 Address: 7638 MERCHANTVILLE CIR
Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL.
Class of Work: ELECTRICAL MISC Township: Range:
Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 27,897.00 Total Fees: 270.00 Subdivision: CRESTVIEW HILLS
Amount Paid: 270.00 Date Paid: 2/28/2020 Parcel Number: 35-25-21-0120-00000-0730
CONTRACTOR INFORMATION OWNER INFORMATION
Name: ELECTRIC TODAY INC. Name: EUGENE MANLEY & LAFIA
Addr: 333 FALKENBERG RD STE B226 Address: 7638 MERCHANTVILLE CIR
TAMPA, FL. 33619 ZEPHYRHILLS, FL. 33542
Phone: (813)653-4221 Lic: Phone: (786)210-5512
Work Desc: INSTALLATION SOLAR PANELS ON ROOF TOP
APPLICATION FEES
ELECTRICAL FEE 270.00
INSPECTIONS REQUIRED
ROUGH ELECTRIC
CONSTRUCTION POLE
PRE-METER
FINAL `
Q
i
REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City
Codes and Ordinances.
i
CONTRACTOR PER OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
I
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
JBuilding Department I,, 2
Date Received Phone Contact for'Permitting � (053 '12-1.
w�- /►
Owners Name 1_G ANLEY Owner Phone Number l 1
210
Owners Address Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESSHWSMS-ry I LOT#
SUBDIVISION ICRE74VIEW LLS PARCELID# -25-21"0i2o-
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN 0 0 DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR 0 COMM = OTHER SVG&rC LA
TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL ^=
DESCRIPTION OF WORK oJll n eD S w W l 1N rots
BUILDING SIZE SQ FOOTAGE ' HEIGHT
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION '
=ELECTRICAL $ �pr 1 AMP SERVICE 'E:Y10' PROGRESS ENERGY = W.R.E.C.
=PLUMBING $ -ll 11 �M� /75r
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION V
=GAS = ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NOV �l Y v
. . . . . . . . . . . . . . . . . . . . . . . . . .... la.l_I�. ..._. . . ..
BUILDER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREN
Address 1h I License#
ELECTRICIANS }� ��/ _ _ !�-_COMPANY—
SIGNATURE `— (�.��_ -REGISTERED - 7 _ FEE"CURREf`--_ ._Y/ Y 1
Address —�_" pL� ice Jr#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/ N I FEE CURREN Y/N
Address License#
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address License#
111111111111111111111111111111111111111111111111111111'1111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fonns;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required orisite,Construction Plans,Stormwater'Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for.all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
I
i
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions. 1
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
1 intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore,:if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application,for lots less than one (1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit.may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is;commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF MENCEMENT.
FLORIDA JURAT(F . 17.03)
OWNER ORAGEN - CONTRACTOR `��
S� s 4it andb ffimi6be m h's Su sc_bed and ffi med) m 4lhiLlJ y
o is/areD n ly o I e or has ve pro uce Who' shave produced
1i n identification. as identification.
JP dk—Mi Notary Public //t�,�,,//��,6 ClNotary Public
Commission No. Commission o.C:3 —
n191768
d,pnn or stamped ame of Notary typed,printed or stampe � �i)• CANDIED)ONESNotary Publirida _� Notary Public-State of Plorida:`Commissia o. Corymission GG 191768My Comm.EW1of� My Comm.Expires Mar 1,2022 Bonded throw h National NotaBonded through NaAsstL 9 ry Assn.
I
I
Service Today or You Don't Pay!
Jonathan Polizzi EC13007848
235 West Brandon Blvd-635
Brandon, FL 33511
i
To whom this may concern,
I,Jonathan Polizzi,owner of Electric Today Inc, herby name and appoint David Ezell to be my
lawful Attorney-in Fact to act on my behalf and in my stead to apply for and receive any and all
permits associated with the specific permit and applications for work located at 7638
Merchantville Circle.
I
i
Jonathan Polizzi
The above license holder,whose name is Jonathan Polizzi,personally appeared before me and is known
by me on this 3rday of rtxc 20 ao
"""' JANIE LINN CASTILLO
AotarylPuWit-State of Florida
i..y� Commission 4 GG 190575
„•, My Coj tm.Expires Feb 27.2022
Banded through National Notary Assn.
INSTR#2020009862 OR BK 10039 PG 3533 Page 1 of 1
01/21/2020 02:17 PM Rcpt:2127336 Rec:10.00 DS:0.00 IT:0.00
Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller
Permit Number. _
Folio/ParcellD#: 35-25-21-0120.00000-0730
Prepared by: KENAAN DAASOUL
Return to: 5001 S.FLORIDA AVE tAKELAND FL 33813
NOTICE OF COMMENCEMENT
State of Florida.County of
The undersigned hereby gives notice that improvement will be made to certain real property,and In accordance
with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement
1. Description of property(legal description of the property,and street address if available)
CRESTVIEW HILLS PB 53 PG 124 LOT 73 OR 8756 PG 3655 7638 MERCHANTVILLE CIRCLE.ZEPHYRHILLS,FL 33540
2. General description of improvement
INSTALL SOLAR PANELS ON EXISTING ROOF
3. Owner information or Lessee information if the Lessee contracted for the improvement
Name EUGENE MANLEY
Address mm MFRCHANTVIL I F CiRct F 7FPHYRHIt f S FI 3i546
Interest in Property. OWNER
Name and address of fee simple titleholder(if different from Owner listed above)
Names _
Address_
4. Contractor
Name JONATHAN POLIZZI r ELECTRIC TODAY INC Telephone Number i813)653-4221
Address 235 W SRANDON SLVD S kmoN FL 33511
5. Surety(if applicable,a copy of the payment bond is attached)
Name Telephone Number
Address Amount of Bond $
6. Lenda�
Name Telephone Number
Address
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may
be seIved as provided by§713.13(i)(a)7,Florida Statutes,
Name Telephone Number
Address
8- In addition to himself or hersetf.Owner designates the following to receive a copy of the Elector's
Notice as provided in§713.13(1)(b),Florida Statutes.
Name Telephone Number
Address
9. Expiration data of notice of commencement(the expiration date will be 1 year from the date of recording
unless a different date is specified)
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COI459ENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PARTI,SECTION 713.13,FLORIDA STATUTES,AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POVED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOU,$ AN ATTORNEY BEFORE COWAENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Signaturo d00<1 m6nm,o un's a Umee's Aut arized OfficeNWrectatParfnerlM3 .$igrudays TlllerOtrae
v' +
The foregoing instrument was acknowledged before me this day of Oby 411)Q dl1 It
mon name of persop i
as �t1.'J1,�d~ for
Type Of
authhoortty,e.g.,cmear,mr%ae,attorney m fact Nam of party an behair of whom[ oument was executed
Signature of N ary Pub fc-S... . Print ,or commissioned name of Notary Pubft
Personally Known OR Produced ID
Type of ID Produce �d I
Rig
ateofFlorida
Matter
GG 255773
22
GODWIN ENGINEERING AND DESIGN, LLC
8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 chad0godwinerig.com
January 29, 2020
To: Zephyrhills Building Department
5335 8th St.
Zephyrhills, FL 33542
Re: Eugene-Residential PV Roof Mount Installation
7638 Merchantville Cir.
Zephyrhills, FL 33540
Plan Reviewer,
This letter is regarding the installation of a new roof mounted Solar PV System on the existing
residential structure at the address above. I have reviewed the attachment plan and have
determined that the roof mounted PV system is in compliance with the applicable sections of the
following Codes as amended and adopted by the jurisdiction:
2017 Florida Building Code 6tn Edition, FBC
ASCE 7 Min. Design Loads for Buildings&Other Structures
Per 2017 FBC,the Roof Mounted PV system will be subject to the following design criteria:
Design Wind Speed(V„it) - 160mph 3sec gust, Exposure Category-C
The PV System consist of the modules, railing, and connection hardware.The system will add a
dead load of approximately 3 psf to the roof.
The existing roof covering is Asphalt Shingle with min. l/a" plywood decking and 2"x 4"roof trusses
24" O.C. The roofing, decking,and roof trusses are in good condition.The existing structure will be
adequate for supporting the additional PV dead load and wind loads.
i
The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the
Ironridge railing and flashings/attachments.The attachments can be attached up to 72" apart.The
mounts should be staggered,where possible,to allow distribution of the design loads evenly to the
structure.The mounts shall be installed with a min. 5/16" lag screw with minimum 2-5/16"thread
length.
i
11111J///
Please see attached documents and contact me should you have any que�t+i�i�sl.
Sincerely, .Z� ® -'%CEAIS••O �i��
D. Chad Godwin, PE 81360 ®' y
.81 ;
Exp. 02/28/2021 _
ST OF
fi4 O ID P
MAL
�/Inllll� jr3��
i
BUILDING DESIGN PROPERTIES SYMBOL VALUE UNIT
BASIC WIND SPEED V 140 I mph Figure 26.5-1C,page 249a
ROOF PITCH e >7 to 27 degrees
MEAN ROOF HEIGHT h 15 ' ft
ROOF SETBACK a 3 ft
ADJUSTMENT FACTOR FOR BUILDING
HEIGHT AND EXPOSURE 1 1.00 Figure 30.5-1,pg 347
TOPIGRAPHICAL FACTOR K 1 Figure 26.8-1,pg 252
EXPOSURE g ��
EFFECTIVE WIND AREA 1p sf
ZONE1 ZONE2 ZONE3
VARIABLE DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT REFERENCE:ASCE 7-10
NET DESIGN WIND PRESSURE(UPLIFT) P„e,313 -32.3 -56.2 -83.1 psf Figure 30.5-1,pg 346
NET DESIGN WIND PRESSURE(DOWN) P-M 20.3 20.3 20.3 psf Figure 30.5-1,pg 346
NET DESIGN WIND PRESSURE(UP) Pie,vv -32.30 -56.20 .83.10psf Calculation:P_u,=hxK„xP_m
NET DESIGN WIND PRESSURE(DOWN) Pn.r aDwn 20.30 20.30 20.30 psf Calculation:Pn.t dD,,,n=1,x K.x P,,,m �
DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT
DEAD LOAD D 3 3 3 psf
SNOW LOAD S 0 0 0 psf
DESIGN WIND LOAD W -32.30 -56.20 -83.10 psf
ASD DESIGN LOAD(UPLIFT) Pd.lgn -22.70 -41.21 -62.05 psf Calculation:Pde,ign=D+SORT(0.6)W(asd)
DOWNFORCE CASE 1 Pd.1gn 3 3 3 psf Calculation:Pd,lgn=1.0D+1.0S
DOWNFORCE CASE 2 Pd.,* 23.30 23.30 23.30 psf Calculation:Pd�lgn=1.0D+1.0W
DOWNFORCE CASE Pd.l.. r 18,23 18,231 psf Calculation:Pd.lgn=1.OD+0.755+0.75W
DESIGN FACTORS&CALCULATIONS FOR THE USE OF L-FOOT TO ROOF TRUSS
DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT
MODULE LENGTH C 5.22 ft
MODULE WIDTH B 3.28 ft
DESIGN LOAD PER MODULE T -388.34 -705.11 -1061.63 Ibs Calculation:T=Area`W
DISTRIBUTED LOAD(UPLIFT) w -59.20 -107.49 -161.83 plf Calculation.w=T/B•2 3r11sP--
DISTRIBUTED LOAD(DOWNFORCE) w 38.21 38.21 38.21 plf Calculation:w=PB/2`A„DD'•,2,z11,p-m
RAIL SPAN BETWEEN ANCHORS POINTS L 6 6 4 ft
POINT LOAD(UPLIFT) R -355.19 -644.91 -647.34Ibs Calculation:R=PLB/2•" "z`•'sD.,row
POINT LOAD(DOWNFORCE) R 229.27 229.27 152.851bs Calculation:R=PLB/2`M,u-2,.ibp -
L-FOOT CONNECTED BY LAG SCREW TO
ROOF TRUSS/RAFTER
Specific Gravity,Rafter G 0.55 0.55 0.55 Table 11.2A,NDS 2005,page 68(Southern Pine)
Min.Dia.of Lag Screw,5/16 D 0.3125 0.3125 0.3125 In
Pullout Value of W 306.87 306.87 306.87 Ibs/in W=1800 G3/2 Da/4
#of Lag screws 1 1 1
Thread Length Td 2.3125 2.3125 2.3125 In Table L2,NOS 2005
Design Pullout Value per Mount Wt 709.64 709.636 709.636 W,=W•#of Lags`Td
SAFTEY FACTOR SF 2.00 1.10 1.10 Calculation:SF=W,/R(Uplift)
sl.oa,Drl 1-AuWY (-H-d) ,
u,ius x.ofmD.sr:eo::I.rrJ,.a,.sr,.rndnr,n�,rNr+aK
•r.-11,4o?..,-fgr••,T 1l .hij r+m.+.4D -
IMrrnsv m v]k�rcM rev 3D,sp,'1)x+n f.4v,+r4'!nx
1.7,nr]�r.nd.nf NISI.+r 3
ftx-2-YwrNwl kd u„ w9-d-0,
Flat hoof Hip R-1(7-<•5 ilry
000
G.bM IIeo1(BS Try G,we Roof(T cis 4f•) � \�
In,. o=on., [d Zo n ■ Co..zar., T
f.n..�.QYG]OS.N.nv.Dni-[rd IV A.YT.O Mrbwv...Osa./.D.1. 0i,
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: 21- 11-20 .
Site: 7 Mer-
e
Permit Type:
Approved w/no comments: Approved w/the below comments: 0 Denied w/the below comments: ❑
This comment sheet shall b -kot with the permit and/or plans.
FEB IS 2020
Kalvdiv!Witzer—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
. - .�,_ .},. I"••3�: .:(.t`,' `;t';:'3:jFYtt'`^ =.(3'„s 1..F.':o E,,1 i liF�?hT£t F'ts: '�€�,,. ^�1:i,
vssv. :vi� :'':iii: :�31 t3'^F;f�t-J.3 s3'd ts'� ',i ;s, :-r�r- -,�•�.x.,yf: .{S�' _ '.7' 4. ..SI:3;; t• 'tx?" � �i"%'j;v.t. - 6 A,
,. 1, a 3: •,{�..�". .. .. - � _
§i
4FIUMN; ✓ e' ,.Av'DC'ANk+lt4� 4d{F.N:i� 1 ` `bi5+•. e.
;€',,:=a?,stir L ,•Jr+.r,;�, ar:tj,;•' .. _ ',�
a ,•t,: �.� rr.::'a<...`rX..... , '.s ,",':$. i3•.`.::f:;:;+1j-rrt',sn•t t..Th<)_
tit.'' xi n:,:'nt:Jj�:1c( ...;.;tii t}Pi^,!s£C�i t•�i '.aEr i-.a f!;nY: '!v;.e.. f;,+ .fie`'.4'� ^i=.. }
,i:r. .ijitt.w>353SL::tT'?G>x;It,}^'r?'."s3: tliliEi^ jai t;tt,ar.
• ;3'=`.§"yf1 hx ':1:�'?'„€Lx'l ¢'>;i$F:s E..°:?'.:S1f°;-
+!5.i
r
`a'`:' �p - .}-T'.'@"i'7' >,¢>gc,x3'.x'F` u.;3?^a ''`'."1;. .,»a a:�t:,•^ 54:T5rs {S d.Q
::::<'ri'°t_> ,»,.�. N`x�,"•aK. s`z'r 1.<'r�'>.. r��r.�»:."..�. +,i»F�'?' L ,t 9c5:
x;•1z ^�-a>+..�.. s..,.,.. :...�'�iAa., ..,.,.r3i'%:i':::..;'�' _�.:$:,.,.. ;:t" .:Ti�a-;"(=,;.
.w
,_,..,....,.:3•_:.' ° �".c,.> ��«.,v"b....t o�'«=«a::�"F:,z3:¢:�'.«.'z'.>._.._. �rr..�>...r^..m.-• •:,»>n-�-.. µme-
YJ.hr da
x, .
^�.
/max -` w4 <�' 7 .. _ ... €Sf .. `.E�El:�•E, .,tYl�i'. .. :�".l
,
a
i g'T
,.:s�i!:., ;r.:;'9'�„7it'i£'•,c£ii:,,. v€�i75��;.1":':,;Vt� 'e J:':f;�:_ ..aE{i:?i:';cry;+�v
,..i r' " �i•'.... , .!h€ttt:!,tr+:...:fs.^•3.=,:{"'r.,a[E[:u,�r
t
E
N
+T,RO _, .
No,
✓�'%'a-'}A.�zi�_ fix--�i'•. �:�:.;;�':7tisy:`..'v �a.:']� �"°`„.�j�`�'�.
✓� i& .e'.'>pp'33%����5. > �1"�...•;N;.. .,ii'":Le�r.... =l.St .:, s :1.''lis Fi.i.s�E^7�:.i ... i!'Z.�:i
Msa i',�w., ':L'.�ut• :7P �){,r;[:?$ :'31n+�'- :f3. ii i':C L!.'f;.':" :'11::;:
Y
£° R,
^
a
ffs
3
VP
•
<
< � l
.
} s
..v,omc
},}f..,..„xc.;::„:ix yt:n�gr: ..ss s x< £• .,
s
t ;
I -.P>}a ;,i:3:,n.>triatr.,..«f hW"t}":u?v. .� .. ka�, ., ;}: .,'•r.t ,; ,...,,_..
' FSCt-tiY,ra'=�..='*„�<'�`x` �i.='.:.':.�„e.4rz?.;;�`,:% "s.�4�✓'...:."::v.:u.:v�`�+"..�,.�i.C""',r�'�.rT:�:. o�.,N"xs'w.+"' �1 ..
wer , V'MiZerl. ,
00
gg�ry ��qq J pry �y q�y �y
II'".. '2 J P3,4� f P370 P O J� i`405, P50
F:
,
Y
�m
4
PV power~ optimization at the Module-level
Specifically designed to work with SolarEdge Fist i€istallation with a single belt
iYiut�ft,L'f5
if next generation inaintenanc€.;with i odole-
4' Up to 25%inure unergy level monitoring
aaiperi€i efficiency izJ .z`:r; I Meet,,;l F.0 requirements for arc fault
protection (AF(I)and Photovoltaic Rapid
v Mitigate's all types of nodule mismatch losses, Shutdov,n System (PVRSS)
from manufacturing tolerance to partial
shading to ociu le-level voltage shutdown for installer
and fireflahter safety
Flexible system design for maximum space
utilization
i
Power e Optimizer
For North America
P320 P340 / P370 / P400 / P4051 P505
b
a bb a b
bt e r1- '1 9320 (for bigbep. O
0002 (for hi
Module .b ee a
ee b eoll current
e n ad
and 4),W11
x •• ♦s
ee
= r,
k,'}>}:;c'•;.^.•?'irs4'f�`;'s'dl'r•' _.. _. _ .. _kE.....
x d
;i.
66 TI>il1 CiLIR3NG C3I EiiATIZl7d(POWER: TI{ I hI R.CQN CTEC1.fp.ON£iA7S1VG.5t3LAR�GG Tt lbER7EEt)'
r'
OtJTF YT-D��k? (a 5�illi DKY(PC7WER PRTIMVER*31SCCyN EC7:Ef?Pf20tvi SOLAf pCt INVERTER QRSQLAFkEDGE l�
I�+ltRTER AEE} .
:.
STANDARD';CMPt3asP�ECE _ � ,
igr": 9$L h
,
i.JtJ:t }({•!+.;'!}{t}'9;i�.3S:{9 c.::.".:s'!;7i.�
iti :;r4
INSTALLATION SPECIFICA,IIONS
,
,
:..,,....,.-• yr, a -� Y i,x 5! :.Y,_
- ::.sq;i{a,•r:A irx5.::i. �j t}'!£.:„yj, .... .e. _. .. .,'a%_fit.
,. ::}'iitYii Ti" ::Y;>..:i:9• __ .i1?:d >'Rti`it<`tz ..
.'C..'.`r'_.
,
rr, �:F�`�FP:•, <.. ...,. .. r.�.�:a c :4.>. �•t.:i„i:'"�i7, .,„ ,. ..�.irn,a ,«.^•Li ..i 9>.'„•r..:.it;'. .• _. .3::a�:r'i ,.
'G,.'9:, •#;`: , •a3;�.. ;r'r.;:'. :Se of a'"• "3r.,- .. 'r,::.r�a:zy.J, _ .. .s?,ra<lF e.- :nJ
i. T x'2:' .>x v .>, •'( ., ri 9r..-r , ,ra�.r51k.rn f ,..y„�t
P r a
b.
+ sr i
.. _.................. . _.
9.L:ttliS✓"��il:rN,"y Y.N;?'{j}}� ;t; �(f%
r.x•'<
r
'(•-,ic?:iGF':93ai.::}. ,.<fr>.R:< 'e>3.:7i?i:i:}:;.'.,l.u,; ,?.r�',q,r:'r.. ..x`?P,:L;lbx:$.P:i_ ..,.:32;ST
A-r.x(Iir'
.,},, -rG4+ ;ii>i::�'4.r,fi,ra z?i;:�4eir,•i- .., .,(>�si ,. _ ...- .. ..r.. ,. -. ..i}v:" .,,•te•,. ii'.<,.�a>..°:y'...,
vR!a2tL"3`3e=it:.>;+'.<;aft-ai`..9Li>•r9^94,�14•'•4�Y,:i>7tiEi: :.. '`}kr±:b+t4:e, 't7`.'3'"9 it3P 1`R r;?�i3Ge,tll'V:ti , I;ffq C'4L'7'<i}0<•l.e{xix,£"i6^td i<-A,-;"a I C�ilu Y'fa<..E. avn,.x,+saax4Yl dp rp ru.. tsa;Fnrs.ts4✓a-.'>'i;ei,:.<rr,.-.•.�t+ate..w..,:7pr>•,•:<(?.fi NAM i<fJm IG:tu^:tx;t>,
� Interic3t
i
i 3.56. �
,
`r
.ram is
.�:•-`
�xa 'L
00
-6Sr
SS
• r ,
S
..:t
t,.
f. .ar va ,.•
- ✓ :Cx
•=f
•i Y ;��•,�,�-may'
�a
v fir ..
}f -M
y : s s'
'}�. ✓�J , �t'..may �'.7j.�:�••��.
n �r`✓� .. .. .Yr`t
MEW
fin :•} .. - s'+'.w�;is�K'.:v'd:�w,.-;1'.'I::�.Y;..:,.
x ti:.
.!£ .v: 4�•' oe•,�y�
,
... 'r. ,..X'.w•. f", t. ,.....:..:..,.y,.f..-. •'fin _
,..:•:sir.
0 2M PSmM dgeas h=-Ah raft .visit 1e wwirw @ R Y)fA-or.ca
installation
Tools Required:tape measure,c3 k fire,sK41'�;s�t
hex socket -
' f 1 ` .
cte: xe3S and snap. 'f}rr .an crzc3 ;3xts.,, .. 1: ,gr ,T3 - e'
to mark flas{�rs['�: ions: ? 11, 1 r fi', s, o >i ri 3 : / "'a e< r
fijjjj�p��,(.{,� �y�� y�y��x /may p. �•}���..,�j�+...� n�yq.} 3�,�+�},,,,��'j,}��{�.,,���___��-��-www���k
$7 �JSd.L�S 7SJiXsI •A Sf�+c;E-tL'3 V�i.ti+`P''�T i' .f V�L1i�4'TG W�JS..` .. ii 3.'3,-CR..i$'LVti 3..1�"!,•;
,,..,...," ./ ',•✓'Y` :r`%y �•y•,���'•;'Ji v'; ...<:, '"i4,:.`...,,rch.,7-'.ti•��:-.-.:::«. '<�,.. ;:f`�Cx'A,. ." iA.
e
-
'I:j°
1�
Syr _J�•^'-'
` ��7•r,
.ia
Aw
..FP"; t ..�:^:X:-i., �sJt ut.. �:T-",'�'».':lrG�*�» r r^'=...A :'?c^`_ ,.3."•�:•-"-. `.,;r�tr;,-•'.
- _t'7 -A.'M (R-�Ts�i�+".-�•,�e' �-xw:F.s+{.. :52_ _•s./`.....y i'�",<:'� r.4;e.....`-'�'. •`-`i°-':.irc-r,`�.. .,,..,.,._-.:.,,�:.--r^,:e,�;�a.�,-»'?'„.Ss.,..-vrr..:";.>,..,r s .d;a--.>:_.ry,z."7` ,.2r.Ra:.,r. .�`:�sr-:,n,w:,.Ks3�<�.�.�:a• :,;•:;; ;.'�,x. -
yy,,,,,,;;;; ��g,,,.,,,��g.y.y� ��,�,,�:•�.'r�.`�,;q.. .:8.` •u»4?�. »,•�?.. 4-� ky:f .�',-?„�„is',aP�;�..r_«r,;:-^�_7-}v
'�`.,.t31;i,EIt:EY"r,L"F."F���%i3i�nti?5'.t"S'�t.R�' «%� �.:'t��` ':a.,C ,�"��f. c^' �i`' ':�w M •�' 'x:, .
.,r ..�.... .r. �''S-`�Yx�"• .;�..y3,,7E�.����r :rx-F, ^"i„-r;�• .r n s. .;
, _�., fit;. .� - �:,:.'•t
i.
` - ,A�r"'.,' e�r•w``•.' •� � tip,.,:,,:.
r`! : cif� .y:.°'`„ yy� .+a._ _ ';•%
_ "_'.Y:'y"" w:r wM1�.:�Y•:,..Sii�y'r 4.',x�`J .p;; yx.�� � 3S'f y'.�'�i'Su^',^':F}. ,L�*,f � 'F:F. �"w'r'��K�tf':k':,
"I 7� ii
�IH
�`'i: :<,,..•.;. .�%c?.'... .s. aa.�.;t,s:. -;vim,,.
T'
i'
to
0 45$torte$;mac.&H,reo3L reSm�We vr�ccti.E;�n itTga isYsr t .�_
L/f
, .:to x
a
{
r Y.: 1✓'
,t,x
y.
y£�,
!•i.x V tF
',• for Nort
h Yh America
(A
U k
>w<
^
i .7 F3-US fSE'f(OOOH-U I SE11400 1-US
ORION
Oft
t' „ ,y `• ,
no o
gy
x;>3�.: 3- r � 3 j,;: ',i f,'r�•,<<�'..y;.�., f �'' .,.w�. � .w.0.,at � r .„"' ,.>3x ;}i 2',� a»»..4.� .,....._,.sa,..�.a "M'^�"»'"„s�' ...._....'r' l.wik.....<,.,�.....,,�....: t?1'.JG�"?.C✓v'
z _
:. z >
x rL�w
rz-
szte
'f:a
s. F a
h0, >•°�;f �„^ `'i��.:r'` •P
��yy {�r gg�� '�: 'fix` t •2
,,.,.>v_..� .'>... .�R....,, .., ,...,.=.n,.. ,v,..H..x�: .g• �m^'ta.^.C;at'. -.Cti:F ,� :g ., gc
4
' 'r., �c,e. 3,'�.�'a'. '.� . s��.�„ •,-` � ix m+&z{<,�".i..efx a1'r`� ..k.. � �:�- iz f _.3
........,,.....„,.._..
.;.q .. ,-.l:v,.,•,,;>�:,.r^..^L:
..r._
_
-ux.i' ..xtf "D<c�" va':p i .. ....._....___......,.__....._.......,..„.-,..._._». �.._._,...._..............._.. ..._. ....
,
4
-
S
Y
F. `_it-.:;$`x -��a e;; •'�w1.s. .:i:°: ip,''a K;.T1 ��bAf' 1 ,.r..,
�`;;?t.' C:s:h`„a,;; s�-rr^'•,
s
,
„
,x,..a,•.^ .:z.,.'.:,...•2.,:-,,-,,.,.,,�m>,...,,,,<.,.,rxz:',.^•s>�"_ ' d
>�;Wh��,<'k•',:�Fa,A^AP
,��a��••'rof l' r '�S # ':.?z,:'z'.at.y'z _`:_1.S:_:a._ro:_'xf n_^�i%iCm y'..n1's..-._";',`i _µ.,,.•uX'€___.. i.�;�, .»_.,.,._,""_,»....,.... ...^�....»...._._..-�_ ......,.,.............
_..............^"
E
,.< "'.<"Vf-m"��{':via a?' .. ,:.?:r,•,x;,e'^� -t ��'�sR"' r"E"�' '�,,,' "-� -�sa.��s>`ra^!C:a,>c>,:YZM.',e.^ l ,_. .«.....,._.,.._.....__...,..,,»..._..._ .»,»__.,_ ....__.....,_..._.______..,..._..T _ ��_...•�.
'a y � •,:r�ai, ;T `i�a;w"'TMaMA cif ;'et�y^„w>f-�. ,v,,. �'D x�, .'�'� _...,..._...,.,,-,.,..--.. .,.....,,,.._.._.,,.._,.,.___..,..,. _..<.._..__.,...___..«.._✓C...,...,,._ .
. ._...,,s•.a:,<" a. 1.� ;.. ,w•�s;�
as �, f<.,,r,... «,r.��`<...�,
>v !k'�t� $ `
.x ...: ; ... �s-az s.t •- < .:>� .r,a `$' n''"�k
.....,..,., „.,'..,*'s^' .'..,-F -.�•.<:` ^_,..-,r-.. 9 1:
..
4w'ra.^,xx";a,"ras-,ai.r,'2 ...:,-.,---.i.._....,_-_•-_...--�+ _.__._.�.
_.. <. _ _rna'p ,,..ta,.^<r .!.>a „e,,f,.a,,,a as•„ - _ _...._.._..___..z._._...._..».,
m k.
..,; .,
_ ".•,a�. .:,s;: ;i - _..fix..tia•_
,..=.'F�<.,<�:.•" � .�.._,. >.,a,} a 'k.,.,...<. 'ay,raa+rs„::ifr3x: t
{
;De� ;>•'rxR4i s..,-.`. ,• ar
Sk,.B'k1'}.�V;y.., ,Y4a;`� ,:sFx,�' .r*.:•�,^� 1F '
,
x
>
t
i..
.�.., " <,a .<:a� s.� a:`a„ :. .is d=<+ >^r r�sx ::€-','�,ct" tBi T>�'e^cG'K•:+�' _ .,,.,-_,,..,..__...,_.._.._ ....»-,,.._._....,. -"-„i§-.—'^ j
�3
3T:<d5
f
,."' :,^r -'^v a. um.�� ., r., :• ,t, of ..... „»
P yL ,
..: � :. P,,,., '�f. a..,,.a x„ c::: '� .,u.' nr ., ,.ry "', '.,;, .A,^+.yrY"•;4YwwY m...^'as°.KQ,..
-
y .zs
7.
-., ..
..... .., _. a • ..... ._. ,-`-. .,. ,.. ..,�,...ar L^'rr+'r""1:2>a.• '
,
:.t`,r:xirr�;r~';'•Cze6:l�iC,'�,Tu" -.._._-.,,^--.............._._......w..w:...:,»...,_.".....,...,, ._ _.........................
'.",>sas:5?*,i:3z.wx.r�L �:�A'xs �� ... ..»•,• >Mi+n"'S�dd fixa+H:',^:3szn!g,kx'sAL'G'+Y.t�rlr^xa+w,`
Li
/+�; . installation uuifi HD- tae:technology
- _
q. CS�2v yam'. •' : ..:�"�< .: ,>.;_.-.,.. '.' .""•'�w;�,4
`r�f3�1CT-vd�s r'�kE.�.E���bi.., ':,.,., .,..::��•,�':.�..,;",k., ':tea`'si1..` .�i,:j:r ,...._._.,',,y.',,,'r«.,--..,,''':-s>'.�+y,' .,,:-- .>: §
B Spedic*designed W atork eti'S.im
,s"rni22r5
- - --- -' --— - - — — — _ A
_ •rlt�iesmtrduT,e"fec:'a�rRr:se�Oxin 8 '�Y��P, j ..;.,�: ,:�.:',''>'-":;-.::..; .::»w-_:,,�.�;,_, .�-�..,...,....,,..
,
d Retord•Evrtzi<inger5trtmc/ t�'
y FbwdVsttacteisss€wrvtonger.s;rirgs l Outdw,and indoor insEail.'Lon crru�c su�sr�.a�� re � L r ,s�'&�x� "_ _.,. _ i xa•a r< ss<a rF
ESace;^at'tt�:'m"eJ:mx.'F: I •t• ` :«kn
! trefegrafeA gtc fauSt pZsftct a a and its 5htttdounti foa q tioreaJ'R<venua tgrzde data,ANSI s'ti :� Y�s t eYBr ar&xaVa ___._,
NEC 2llband2t117.f32t' rf;mda a9Qt2 05fEk5YaatryJ:
x
x
L&SBCT(5'2n:e iy'::<"1:,§.rsT'c;4xivre' I .............
..,,._........,..._.....-.,...........
..._.....,
^tir dessw.g};,'�snun;xc,rxc+au.!swf.:5:a"ct3**t � i
solar,
'�R hyb'x,,a0.'s"A S2at'8�."t.aa�:vc•.¢attm,a^n wk29,w i:+'xx.*r<>Nr R,1'C.o>'�'+:a�.:
^`9 L,'�z".'k^`ci1?utre' f°ds':2:'"ro'a'ra"»w S.i3'.YSscv;3t-'.*'^`r":`W'4-L5;»w}Yr:¢,'Lt,1�1•'+d*% F
S£3?s`43L�G'.Ct'NYd Reim
r•am='sdv e v :e+H c".;ErY.+Rs €
es-A>a:nwcR.�>.x:w�,sw..+�,.-y,. •m«r+;s.'»e.,w.s,e.�az�-e+�,2+a.�aas*`pa+,ram�a,+aa�..Rs>. .�
� 1 4 SFS �.y ^• ' �,dc."N 5 Z ,t� �. t9:- Nre..
$ o. . r
`�", l� �{.�'� �y.�.�".'' �sga''g',`��+^,��„bran xgy ''yi«.;g �.;:'t�.:x,:::•`.�::,. '�`€ s
��� �'Y9 Eas'. 67rF' a.a I� A
ra
rat
law
.$ vX '�• i.W3V ^ 9 V; 1 ca.fw:Y 1 .'• B'`w A„'N+i,)' . .. e
.3
a
• t
. txn
rsj
�. .
x
. . w
`r^' ;t; d
4
`%fY'; 4r.+$�: ,n.R ��., V "� �.y%�� 4�{wY4e�' � '�..CF,.�4��$ �'r6 i:8.. nt�5
F
O
NO
T
Inverter Type: Solaredge
PV Panel: (29)Panasonic 325W 3' Access Pathway
Racking: Iron Ridge R-2
Total Wattage: 9,425W O
Roof Type: Composition Shingles # Modules (9)
Wind Load: 7 to 27 Deg
Fastener Type: Use 5/16"Dia 5"Lags F Pitch: 22'
Sheet Index Azimuth: 90O
S-1 Cover Sheet/Se Plan ___ L S-2 Detail T T
E-1 One -Line H
S-lA Mounting Plan O CODES FLORID L COMPLY WITH PREVAILING
A BUILDING CODE,
enera otes: NATIONAL ELECTRIC CODE,
SolarEdge SE7600H-US Inverter AND THE CITY OF ZEPHYRHILLS
located near utility meter
U ORDINANCES
-SolarEdge P400 Optimizers O
are located on roof behind each module.
-First responder access maintained and REVIEW DATE FEB , 6"
from adjacent roof. E O = ti CITY OF ZEPHYRHI
-Wire run from array to connection is 60 feet. PLAN EXAMINER
`,����11111111//��� Utility Meter R-1 t�
,•�`���C=G°�`'��, Godwin Engineering and //// ' # Modules (20)
` Qt1,"�GENgE -COGEN Disconnect
•,1 " Design,LLC Located adjacent to • O
• 1 ; * = 8378 Foxtail Loop Utility meter Pitch• 22 Layout Subject to Change Based on Site Conditions
* = Pensacola,FL 32526 -SolarEdge Azimuth 1800
of /4 D. Chad Godwin,PE SE7600H-US
:
"LOR G%V ?' Chad®godwineng.com Inverter
'j/ $S.'-- I i ACmcSa1LLC
System meets the requirements of NFPA 1 2015 Edition,Chapter 11.12
11111 Meets All Editions of Florida Fire Prevention Code 6th Edition Customer Info: 5001 South Florida Ave, Ste 203
Legend ® Chimney Lakeland, FL 33813
® First responder access 855-577-7999
Satellite
Utility Meter O Vent Pipe Represents all Fire Clearance 1st Responder Access T
Do p Manley Eugene Date: 1.22.20 l�
PV Disconnect LV1 SolarEdge Inverter including Alternative methods minimum of 36" unobstructed as per
Section R324 of the 2015 IRC 7638 Merchantville Circle, Drawn b . CW
C b
2017 FL Residential Code & FBC ,6th Edition (2015 International Residential Code - 2nd Printing Zephyrhills, FL, hecked 00
modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 33540 Rev Date:
International Energy Conservation Code, City of Zephyrhills Code, 2014 National Electric Code. e•
Pa
g S-1 Compass for Aerial
OF
hV nR Se XEt 104 Rai] R
' Soar Madub
5/16"a 5"Stainless
Steal Lag Bolt .r.
Ironridge XR-100
'Ironridge XR-100
General Notes:
- L Feet are secured to roof rafters.
@ 72" O.C. using 5/16" x 5" stainless Godwin Engineering an
steel Lag bolts. 8378 Foxtail Loop ;" \ %
- Subject roof has One layer. Pensacola,,FL 32526
- Allpenetrationsr 1 n gG��• . •
ae sealed and flashed. c � �, nom •,; A ;• ,
4RIDP
Roof Section Pitch Roof Rafter and Spacing Overhang Notes:
R1-R2 5/12 2x4 @ 240 C 12 Truss
5001 South Florida Ave, Ste 203
Customer Info:
p as Designed er ASCE7-10 Inverter Type: Solaredge Lakeland, FL 33813
g PV Panel: (29) Panasonic 325W 855-577-7999
Racking: Iron Ridge Manley Eugene Date: 1.22.20
Total Wattage: 9,425W Drawn b : CW
Modules mounted flush to roof Roof Type: Composition Shingles 7638 Merchantville Circle, Checked b :
�� Wind Load: 7 to 27 Deg Zephyrhills, FL, Rev #: 00
no higher than 6 above surface. Fastener Type: Use 5/16" Dia 5" Lags
33540 Rev Date:
Page: S-2
Equipment list
PHOTOVOLTAIC SYSTEM
PV: EQUIPPED WITH
p Y RAPID SHUTDOWN
1 2 3 0 0 0 1.7 rI ]
8 (29) Panasonic VBHN325KA03 LABELPER NVICE PANELF RRAPID SHUTDOB
PANEL OR SERVICE PANQ.FOR RAPID SHUTDOWN_____ riCOMPLIANT SERVICES
_ _ _ _ _ (29) SolarEdge Power Optimizer P-400 PHOTO VOLTAIC
OISYSTEM
f CTU RENT:DC 236ANNECT
DC
MAX POWER POINT VOLTAGE:400 VDC
(1) stri A AI>P1Y to
ng of(11) MAX SYSTEM VOLTAGE:480 DC disconnect/inverter
-v- -v -_-u--- - ______ - -v- -u--ni
(1) string of(18) MAX CIRCUIT CURRENT:15 A[ i r i ri
WARNING
1 2 3 0 0 0 r 0 11 ELECTRIC SHOCK HAZARD
Inverter: IF GROUND FAULT IS INDICATED ALL
_ _ = o o 0 = _ (1) SolarEdge SE7600H-US CONDUCTORS MAY BE LLY GROUNDED
NGRO UNGROUNDED
Apply to Inverter
SolarEdge AC/DC Safety Switch AND ENERGIZED
WARNING
ELECTRIC SHOCK HAZARD
Power Optimizer AC Disconnect: DO NOT TOUCH TERMINALS Apply to Disconnects
Solari 60A Disconnect TERMINALS ON BOTH THE LINE AND
Typ
LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
All wiring to meet the 2014 NEC and ELECTRIC SHOCK HAZARD Apply to each J box,combiner
2015 Energy Code THE DC CONDUCTORS OF THIS box, disconnect,and device where
PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE energized, ungrounded circuits
ENERGIZED maybe exposed during service.
WARNING
(4)#10 AWG Wire SOURCES UTILITY POWER SUPPLY
GRIDANDPV Apply to MSP
(1)#8 EGC SOLAR ELECTRIC SYSTEM
In 3/4"EMT typ or • • •
FMC,PVC,LFNC • '' Main Distribution Panel Apply to Disconnects
(depending on route to ' ' ' • A 200A Main
inv.Metal if interior)
L1 L2N
Line Side
Inverter Output Ckt SolarEdge Inverter Tap M Godwin Engineering an
To Overcurrent Protection Device
SE7600H-US 32° Design,LLC ��� O,•'�,\CEIy$-���/ice
AC Max Output Current 32 w/Integrated Disconnect 60A Service Rated 8378 Foxtail Loop � Z
AC Max Ou ut Current* 1.25% 40 _ Fused Disconnect Pensacola, FL 32526 ' '
f Overcurrent Protection A 40 = _ ,�, Neutral to Ground Bd "D
No. of Current Ca in Cond <4 AC DaoAanecton D!}•�pC�h�Sd GodwtII, PE 0'.
Manual Disconnect Chad@godwineng.com
Conductor Gau e AWG 8 Fus i�s�=20 ,.C.,
N
Refer to NEC 312.8 for
Conditions on taps in switc
J and over current devices
GrouLr ITI nd Enclosures.
�� [f the conditions are not
#6 L 1,L2 & neutral nr to beh osta l d c sar tc
#8 L1,L2 & neutral In @ least 3/4" Conduit (1N#8AWGEGC&GEC
#8 Ground
Figure 690.56(C)(1)(a)Label for PV Systems that 5001 South Florida Ave, Ste 203
Shut down the array and the conductors leaving the array In @ least 3/4 Conduit
Lakeland, FL 33813
Note: GEC NOTES Customer Info: 855-577-7999
Provide a grounding electrode system for an
In Case of Emergency Call -All wiring to meet the 2014 NEC and ungrounded system per 690.47(C)(3). Date: 1.22.20
GEC must be installed per 250.64
ACDC Solar LLC Florida electric codes. Manley Eugene Drawn b CW
- GEC must be continuous un-spliced or irreversibly spliced from • :
60A Disconnect inverter to existing service ground system or continuous from the 7638 Merchantville Circle, Checked by
:
at 855-577-7999 -Type of conduit to be determined arrays to the existing service ground system. Zephyrhills,rhillS FL, Rev #: 00
yI� - If GEC is not continuous from the array to the existing service ground p y
on site by contractor. an additional ground system must be provided from the arrays to a 33540
Must be metal if DC ran interior. grounding electrode per 690.47(D) Rev Date:
GEC must be min#8 AWG and installed in conduit E-1
f� Page:
1 01_511
1 1 J
711
O 21'_3"
11' 2"- O
s O
59'-8"
42'_4"
R-1 R-2
31_611
{ # Modules (20) # Modules (9)
Pitch: 22°
Pitch: 22° 5'-3"
17' 8 Azimuth: 180° Azimuth: 90°
14, 9 \��� �N�EC" Q �i
Godwin Engineering an � O • c .9<.O �i�
Design, LLC
8378 Foxtail 8
Loop
Pensacola, FL 32526
D. Chad Godwin, PE ► ',� OP
� °F '
ORI ,•'
7 Chad@godwin i •eng.com �� �0-_.
4,
I �
Splice Barg Max cantilever is 24" as per manufacturer spec. `
Flashings Max56 * i * i AC
UFO's 72 Cantilever = (�
Max Span )—_72 (�)—_24
Sleeves/End Caps 28 Customer Info:
5001 South Florida Ave, Ste 203
Solardecks 2 Inverter Type: Solaredge Lakeland, FL 33813
Ground Lugs 7 PV Panel: (29) Panasonic 325W 855-577-7999
Racking: Iron Ridge Manley Eugene Date: 1.22.20
Total Wattage: 9,425W 7638 Merchantvi11 Circle Drawn by: CW
,
{ Roof Type: Composition Shingles Checked by:
Wind Load: 7 to 27 Deg Zephyrhills, FL, Rev #: 00
Fastener Type: Use 5/16" Dia 5" Lags 33540 Rev Date:
Page: S-lA
Pwiic
-.. HiTo ..- ... ,.�.
I
z yX ^'�' f _ £ � • R '��'-};r *xJttS- fit::' <..T-T`w,.as
} Ng � uses ultra-thin ELECTRICAL SPECIFICATIONS PERF
ORMANCE WARRANTY
amorphous silicon Layers,TheseTh1ndéttyers teduce losses, :�,►¢ !
resulting in highereñergy.output thnthriventionaL panels. atedPowertpmaal5 325W 320Wf`
,tea n.. s ,k .. .., �'*" 7A•,•r
astmimt{'owets tVilmt• a4 21r a E n
II M go kB.W
M"mum Power Current tlpmi 5 50A S dfldi
., Upan t ircuit=Yettage 76tM11 t #leeK
r= r Shah CircuitCurtent itacI 5 94rk 5.8A
�� Yi° ttrmttlttature�oe1tiiPmaisk �' •�` � � �,a '
TemperatureCoefficientMc! O17V(C -t1$V!!C
r - rnW.. a i► re s='rs+mp$suwmCoettfetent hset axtm+Vót� -= ,-
NOCT 44 o^c 44.4°
lo pleIMlfk I C.svi MIIltr
M` CECi�TCRat6+giT9ntatlyel; 0 a, .'
Cell EMk ency I 2i 895 21 r OIMENSU3NS
it.uet.stele Sauer.. -4: Maitrtygett�r tg fil4 `V
_ r= �,, 41fd+r'w+f�r� iUwrna�a�sa+Me.nMyM• ,.. " ,, '. , , "_. ,,' ' � '<- ';� �►. - are>nlet. -
—_ « , r.euar ew r.e.m64rtbn d Watts per F!r t8.03W 1T BVli 5
Y�eGarM eWin.eNwl
� tl.:rt.•«:tr..ree.trcat " Maililt�firtS�ett:tr►V$ltagp• '�.� ..� ,� �
-- tana..q�a..Ueraa« " SerwC*Fus*Ratio
15A 1*�L
wtgar�►et�iti .t I t °iI�
- -
A A
ttlf"sliiT"sn`o:CTie+u'yMeoetw. : .:. ',�
r
eM"aa'" M€C$ANtCAL SPECIFICATIONS a j
odule which= tntemaM Bypass Diodes I 4 ptlss"Dicdei
a �
erature coefficient �.�`
P
'�"s._`K tie,s'S{:. _` %'.•w. a!IWy �'
{ , dNterwa Wtactoafxoik:et " a
theticatty desigtte Weight 419t1Allst
_ _.. sofa it�l=
txWaH
mepstorw
DNY+S3tr Cable Length.Male/-Ferrate 402/402111020/1020, n. mm At .tswtrr�esrutrl
4 4
••
abitl '
.: twr � «e �,,.=s"t> •.. :. FYMOi0Ut8= r ���> t�
_-- Mtllltuh.J Y5 t i'.CAed a a a
onneclorType^ I, Mute-Canta48,Type IV tt4C MSIlwsaiiner.4 ati iva
tl
C _a itS. . .r' Stat{GV�nti�StgNtt:Sttk I �sr�tuww4
25 Year Product and Performance Warranty**, 65.3 ca
m,nMfo f sus m, a aptaRa s'
, „, :. ,x ,. .-�. y ,w•. .� �« 63,7ra2oZri4.�,[o�IMaIsI
Pallet Ot S L W!N �;:
..,• to u, r lndttst leading-.25 ear product workmanship rY . X P p .,: t,ft : «rttti
OuatrttyePerPettetFPuUpk4q t ht r $iw,
ry Leading and performance warranty is backed by a century
� a Quantity per Container ! r172,prs '
P .P- No old-company- anasonic. owes out ut is
v x < P dry,
r2ttcontatnst f "W xr tlrPEILiI�WtfMtRatllAttl
- t �t lrel guaranteed to 90.76%after 25,years,far greater
- . , 7.tiD'
IIII `'-w•�''� - other . - -,= , ,'-.`
tioaew�m�
than companies.
Operating Conditions&Safety Ratings000
. .. 508
«gip Higherfhct•ency 19.4% Operating Temperature 4O F to t85+F t-40'E Po M rt 4.00
tia0 Sa fety lm t VetgcAYI haUstons tE5 2q0 ,.....__.
Of Enables higher pawed output and greater ene. y ��S ..- d w m
« c. UL 1703 cuLvNlk tll
internalproduction Safety&Rating Certifications '
�and-20 ttte na yields. H17m-provides maxtmurr� for crc. �. 2A0 _._ { { '
5 your G mtted' p , OL t2G3 Fire Classd;callon y : C
mss" .Se current ranee Limited Warranty 25"*Yrs Workmanship aniI Powef OutE ILir ad' f
.' ., �_..-_,. .�� ,._.,�.t� , Manu�tunn ccaUb� USA . str e0 70`
gL � ,_mss
:t 0 30 40 ;a
Voltage tV
°` Enhanced Fame Design NOT1t5tandaptlestCond�aat ,Airmasst;.5 istad nre:IDUOf! € RtiIur,ce tf ormedat .
. _ � L , ICaOhmpkatwa2S CI
9 Ma iliiyfn power of dettvei►F9r guaranW oondittons;please cl:ecit
_ i ht � 40 f i t ,.
� !� Anew , mm came ncreases durabi i and. tam
, n .rn5tdtWttol,need.., red.. ouewe65lte ,:`
� � ., ter.
11 _... mar�rtnrecewetwen ,drarlSi: PraAstctwark .t7t
tytp .;: r
_ . nt st n t e able to handletoads.of u t 54lfOR : �
_ . � ,at � re h�being a e a «>h ftlt�n ttstylxs. . � ,;
i r ,.. ,#� to year e,.•;.i, s..ex..Y="... ,. „u _
annuM yaa 2
Also,the water drainage system gives rain voter
_ -w
,.. - _, .y_,xu . "� .. .�P a,..,Cam., z✓'S 1 - g ,zx .y ,a,:,.: x.:,.y...,;,
_ Sat SSt4lranaw wrthlhe4iwtltAe. �s w � x
seduces and snow melt a lace to go,reducing water " iii- f _ .a � t-F£...
. , - .F P 9 way .
0.70% and soitin ess dirt on the module means more , ica sandf a y .. t. Aa..
more power sunlight getting through to generate power.
•
- .� . ,_ ,_,� � �HfTa'isilregfxieiedi►adatnarlkoiPatta?r7rrttGeeup-_
Single Phase Inverter
with HD-Wave Technology for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/
bve to ` SE7600H-US / SE10000H-US / SE11400H-US yPhase
OUTPUT
with Wve
a Technology
3800 @ 240V 6000 @ 240V 11400 @ 240V
Rated AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA
fNiiiEk3800 @ 240V 6000 @ 240V 11400 @ 240V
Maximum AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA
AC O ut Voltage Min.-Nom.-Max.
��'� (,, ( t ' / cc G ``�'' (211-240-264) ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac
S�E 000 -US I S OOH�US I SES000H-US / SE6000H—VS / AC Output Voltage Min.Nom.Max. ✓ Vac
0. ' �QOtir '" ) 1 I400H-US (183 208 229}
AC Frequency(Nominal) 59.3-60-60.5m Hz
M, Maximum Continuous Output
Current @240V 12.5 16 21 25 32 42 47,5 A
Maximum Continuous Output - 16 24 - - 48.5 A
Current @208V
GFDI Threshold 1 A
uY Utility Monitoring,Islanding
Protection,Country Configurable Yes
Thresholds
INPUT
' Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W
Maximum DC Power @208V - 5100 - 7750 - - 15500 W
Transformer-less,Ungrounded 1�5
Maximum Input Voltage 480
Nominal DC Input Voltage 380 400 Vdc
Maximum Input Current @240V1A 8.5 10.5 13.5 16.5 20 27 30.5 Adc
Maximum Input Current @208Vm - 9 - 13.5 - - 27 Adc
Max.Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground Faun Isolation Detection 600ka Sensitivity
Maximum Inverter Efficiency 99 99.2 %
CEC Weighted Efficiency 99 99 240V %
g 98.5 @ 208V
Nighttime Power Consumption <2.5 W
ADDITIONAL FEATURES'
Supported Communication Interfaces R5485,Ethernet,ZiigBee(optional),Cellular(optional)
Revenue Grade Data,ANSI C12.20 Optionals
Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect
Optimized installation with HD-Wave technology 2017690'12
STANDARD COMPLIANCE
Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCl according to T.I.L.M-07
I Specifically designed to work with I Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI)
power optimizers Emissions FCC Part 15 Class B
I Record-breaking efficiency I Built-in module-level monitoring INSTALLATION SPECIFICATIONS
AC Output Conduit Size/AWG 3/4'minimum/14-6 AWG 3/4'minimum/14-4 AWG
Range
I Fixed voltage inverter for longer strings I Outdoor and indoor installation DC Input Conduit Size/#of Strings/ 3/4 minimum/1-2 strings/14-6 AWG 3/4'minimum/1-3 strings/14-6 AWG
AWG Range
Dimensions with Safety Switch 17.7 x 14.6 x 6.8/450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/
I Integrated arc fault protection and rapid shutdown for I Optional: Revenue grade data,ANSI C12.20 (HxWxD) 1nm
NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg
Noise <25 <50 dBA
I UL1741 SA certified,for CPUC Rule 21 grid Cooling Natural Convection
compliance Operating Temperature Range -40 to+140/-25 to+6014(-40'F/-40-C option)w
Protection Rating NEMA 4X(Inverter with Safety Switch)
For other regional settings please contact SolarEdge support
O I =@@
m A higher current source may be used;the inserter will limit its input current to the values stated
w Revenue grade inverter P/N:SF�000cli-US000NNC2
Bolaredge.com A For power de-rating infomwtion refer to https!/www.solaredge.com/sitesrdefaulVkleslsL-temperature-demdng-nofie-na.pdf
rn-40 version P/N:SEl000rH-US000NNU4
O swr;dam TiChrglOgies,IrK All rghte reserved.soU1REDGE,u,e saarEdge logo,OPr1MED 9Y SOIMFDC.E�tnamtrks«regletarad vedamrb or saer¢rge Tethe7bgiee,MC Aa RoHS
/ Power Optimizer
For North America
Power Optimizer
P320 / P340 / P370 / P400 / P405 / P505
Fcr North America,
ti
zo P ' r aF P400 / P405/ P505
fl,
Rated Input DC Powerw 320 340 370 400 405 505 W
Absolute Maximum Input
Voltage 48 60 80 125w 830 Vdc
Mc at lowest temperature)
MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-83 Vdc
___________ Q __________________________________________________ _______________
yq imum Short Circuit Current 11 10.7 14 Adc
Maximum DC Input Current 13.75 12.63 17.5 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.8 98.6 %
Overvoltage Category II
9 re9 rY
Ii OUTPUT DURING OPERATION(POWER E?Pt1Gi 1ZECNNECTEDTOÔPERA17NG OtAAEDGE.INVERi'ER�
Maximum Output Current 15 Adc
Maximum Output Voltage 60 85 Vdc
..- n= FEWER OPTIMIZER E - R
OUTPUT DURING STANDBY( bsld ,lf IIEQ
INVE
RTEIt OFF'l - - -
r s Safety Output Voltage per 1±0.1
Vic
r a Power Optimizer
- STANDARD Gt?MPUAIVCE � �
EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3
EC62109 1 closes
RoHS 1 (class
5 } s
-st
INSTALLATION SPECIFICATIONS
Maximum Allowed System 1000
Voltage
• Compatible inverters All SolarEdge Single Phase and Three Phase inverters
129x153x33.5 129x159 x49.5 129 x 162 x 59
Dimensi / /ons(WxLxH) 129x153 x27.5/5.1x6x1.1 5.1x6x1.3 5.1x6.3 x1.9 S.tx6.4x2.3/ mm/in
Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb
Input Connector MC4w
Output Wire Type/Connector Double Insulated;MC4
Output Wire Length 0.95/3.0 12/3.9 m/ft
Input Wire Length 0.16/0.52 m/ft
Operating Temperature Range -40-+85/-40-+185 'C/'F
PV power optimization at the module-level Protection Rating IP68/NEMA6P
Relative Humidity 0-100 %
N Rated SIC power of the module.Module of up to+5%power tolerance allowed
W NEC 2017 requires max input voltage be not more than 80V
Spy,�yf,,,,41l designed towotic with SolarEdge M Fast installation with a single bolt r°For otherconnectortypes please contact SdarEdge
l vartets
I Next generation maintenance with module-
Up to 2 %more energy level monitoring
P320,P340,P370,
Minimum String Length P400 8 10 18
It Supet'ior efficient(99:5%) I Meets NEC requirements for atc fault (Power Optimizers) P405/P505 6 8 14
protection(AFCI)and Photovoltaic Rapid Maximum String Length 25 25 50
I Mitigates 10
ga types of module mismatch losses, Shutdown System(PVRSS) (Power o imizers)
from fanufactunn' toletance to partial5700(60-5114 5250 6000m 1275010 W
.
Maximum Power per String 5E7600-US SE11400-
shading I Module-level voltage shutdown for Installer Parallel Strings of Difrerent Lengths US)
and firefighter safety or Orientations r�s
It flexible design for maximum space w For detailed sting sizing information refer to:httpi/www.sdaredgecore/sites/defauh/fiks WN-slzln9_na.pdf
lttlliZdtt•�3Tf 61 It is not allowed
more mix
30 5/P505 with P320/P340/P370/P400 in one string
as thingoptimizers does not meet NEC rapid shutdown requirementz safely voltage will be above the 30V requirement
! m For SE14.4KUS/SE43.2KUS:It is allowed to install up to 6,500W per thin]when 3 strings are connected to the Inverter(3 strings per unit for 5E43.2KU5)and when
the maximum power difference between the strings is up to 1,00aw
e For SE30KU5/SE333KUS/SE66.6KUS/SE100KUS:It is allowed to install up to 15,000W per string when 3 strung are connected to the inverter(3 strings per unit for SE66.6KU5/SE'b0KUS)
and when the maximum power difference between the things is up to 2,00(1W
solaredge.com so l a r - w
C SciarEdge dogles[tolls ,r, =of the s Dr s« are tra .a,., t,a d= .,max r,.�
of oth C E ROHS
er trademals mentioned herein are tradenwds of thpr regrective wenre.oatc UI2011 V1die G Purrs Si, dto driegewXMrrt notice.
/lr IRONRIDGE XR Rail Family XR Rail Family
The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
Solar Is Not Always Sunny
design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match.
-
Over their lifetime,solar panels experience countless
extreme weather events. Not just the worst storms in years,
but the worst storms in 40 years. High winds capable of
ripping panels fro n a root,and snowfalls weighing i
enough to buckle a panel frame. `
XR Rails are the tructural backbone preventing _ _ —
these results.Th y resist uplift, protect XR10 XR10o XR1000
against buckling rid safely and efficiently XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1 000 is a heavyweight among
transfer loads into the building structure. rail,designed for regions with light or mounting rail.it supports a range of solar mounting rails.It's built to handle
Their superior sp nning capability no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans up to 12
requires fewer ro I attachments, remaining light and economical. maximizing spans up to 8 feet. feet for commercial applications.
reducing the num er of roof -- • 6'spanning capability • 8'spanning capability • 12'spanning capability
penetrations and a amount Moderate load capability • Heavy load capability • Extreme load capability
of installation tiro . # Clear
lInternalr&black anodized " black anodized finish • clear anodzed finish
spices available • Internal spaces available
Rail Selection
The following table was prepared in compliance with applicable engineering codes and standards. Values are
based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean
Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.
. �I -I
Force-Stabilizing Curve 1Q
Sloped roofs generate both vertical and lateral 120
forces on mounting rails which can cause them
to bend and twist.The curved shape of XR Rails I�One
is_.specially_designed to increase strength in both 1W
directions while resisting the twisting.This unique
feature ensures greater security during extreme
weather and a longer system lifetime.
10-20
140
10 .x I
100-
30
{
XR Rails are frooR e offers6000-series
_ �0 .
Compatiblewith Flat&"Pitched Roofs Cl rrosio are made Mat als
mpalIbIswith • a range of tilt leg aluminum slay,then protected with an t# 160
FIahFaot and options for flat anodized finish.Anodizing prevents surface
other pitched hoof I roof mounting and structural corrosion,while also proving 5070 160}
attachments. applications, a more attractive appearance.
80-90 160;"a