Loading...
HomeMy WebLinkAbout20-22533 CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 22533 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:22533 Issued: 2/28/2020 Address: 7638 MERCHANTVILLE CIR Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 27,897.00 Total Fees: 270.00 Subdivision: CRESTVIEW HILLS Amount Paid: 270.00 Date Paid: 2/28/2020 Parcel Number: 35-25-21-0120-00000-0730 CONTRACTOR INFORMATION OWNER INFORMATION Name: ELECTRIC TODAY INC. Name: EUGENE MANLEY & LAFIA Addr: 333 FALKENBERG RD STE B226 Address: 7638 MERCHANTVILLE CIR TAMPA, FL. 33619 ZEPHYRHILLS, FL. 33542 Phone: (813)653-4221 Lic: Phone: (786)210-5512 Work Desc: INSTALLATION SOLAR PANELS ON ROOF TOP APPLICATION FEES ELECTRICAL FEE 270.00 INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL ` Q i REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. i CONTRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 JBuilding Department I,, 2 Date Received Phone Contact for'Permitting � (053 '12-1. w�- /► Owners Name 1_G ANLEY Owner Phone Number l 1 210 Owners Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESSHWSMS-ry I LOT# SUBDIVISION ICRE74VIEW LLS PARCELID# -25-21"0i2o- (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN 0 0 DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER SVG&rC LA TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL ^= DESCRIPTION OF WORK oJll n eD S w W l 1N rots BUILDING SIZE SQ FOOTAGE ' HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION ' =ELECTRICAL $ �pr 1 AMP SERVICE 'E:Y10' PROGRESS ENERGY = W.R.E.C. =PLUMBING $ -ll 11 �M� /75r =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION V =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NOV �l Y v . . . . . . . . . . . . . . . . . . . . . . . . . .... la.l_I�. ..._. . . .. BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Address 1h I License# ELECTRICIANS }� ��/ _ _ !�-_COMPANY— SIGNATURE `— (�.��_ -REGISTERED - 7 _ FEE"CURREf`--_ ._Y/ Y 1 Address —�_" pL� ice Jr# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N I FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# 111111111111111111111111111111111111111111111111111111'1111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fonns;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required orisite,Construction Plans,Stormwater'Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for.all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW I i NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. 1 UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the 1 intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore,:if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit.may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is;commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF MENCEMENT. FLORIDA JURAT(F . 17.03) OWNER ORAGEN - CONTRACTOR `�� S� s 4it andb ffimi6be m h's Su sc_bed and ffi med) m 4lhiLlJ y o is/areD n ly o I e or has ve pro uce Who' shave produced 1i n identification. as identification. JP dk—Mi Notary Public //t�,�,,//��,6 ClNotary Public Commission No. Commission o.C:3 — n191768 d,pnn or stamped ame of Notary typed,printed or stampe � �i)• CANDIED)ONESNotary Publirida _� Notary Public-State of Plorida:`Commissia o. Corymission GG 191768My Comm.EW1of� My Comm.Expires Mar 1,2022 Bonded throw h National NotaBonded through NaAsstL 9 ry Assn. I I Service Today or You Don't Pay! Jonathan Polizzi EC13007848 235 West Brandon Blvd-635 Brandon, FL 33511 i To whom this may concern, I,Jonathan Polizzi,owner of Electric Today Inc, herby name and appoint David Ezell to be my lawful Attorney-in Fact to act on my behalf and in my stead to apply for and receive any and all permits associated with the specific permit and applications for work located at 7638 Merchantville Circle. I i Jonathan Polizzi The above license holder,whose name is Jonathan Polizzi,personally appeared before me and is known by me on this 3rday of rtxc 20 ao """' JANIE LINN CASTILLO AotarylPuWit-State of Florida i..y� Commission 4 GG 190575 „•, My Coj tm.Expires Feb 27.2022 Banded through National Notary Assn. INSTR#2020009862 OR BK 10039 PG 3533 Page 1 of 1 01/21/2020 02:17 PM Rcpt:2127336 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Permit Number. _ Folio/ParcellD#: 35-25-21-0120.00000-0730 Prepared by: KENAAN DAASOUL Return to: 5001 S.FLORIDA AVE tAKELAND FL 33813 NOTICE OF COMMENCEMENT State of Florida.County of The undersigned hereby gives notice that improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement 1. Description of property(legal description of the property,and street address if available) CRESTVIEW HILLS PB 53 PG 124 LOT 73 OR 8756 PG 3655 7638 MERCHANTVILLE CIRCLE.ZEPHYRHILLS,FL 33540 2. General description of improvement INSTALL SOLAR PANELS ON EXISTING ROOF 3. Owner information or Lessee information if the Lessee contracted for the improvement Name EUGENE MANLEY Address mm MFRCHANTVIL I F CiRct F 7FPHYRHIt f S FI 3i546 Interest in Property. OWNER Name and address of fee simple titleholder(if different from Owner listed above) Names _ Address_ 4. Contractor Name JONATHAN POLIZZI r ELECTRIC TODAY INC Telephone Number i813)653-4221 Address 235 W SRANDON SLVD S kmoN FL 33511 5. Surety(if applicable,a copy of the payment bond is attached) Name Telephone Number Address Amount of Bond $ 6. Lenda� Name Telephone Number Address 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be seIved as provided by§713.13(i)(a)7,Florida Statutes, Name Telephone Number Address 8- In addition to himself or hersetf.Owner designates the following to receive a copy of the Elector's Notice as provided in§713.13(1)(b),Florida Statutes. Name Telephone Number Address 9. Expiration data of notice of commencement(the expiration date will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COI459ENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PARTI,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POVED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOU,$ AN ATTORNEY BEFORE COWAENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signaturo d00<1 m6nm,o un's a Umee's Aut arized OfficeNWrectatParfnerlM3 .$igrudays TlllerOtrae v' + The foregoing instrument was acknowledged before me this day of Oby 411)Q dl1 It mon name of persop i as �t1.'J1,�d~ for Type Of authhoortty,e.g.,cmear,mr%ae,attorney m fact Nam of party an behair of whom[ oument was executed Signature of N ary Pub fc-S... . Print ,or commissioned name of Notary Pubft Personally Known OR Produced ID Type of ID Produce �d I Rig ateofFlorida Matter GG 255773 22 GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 chad0godwinerig.com January 29, 2020 To: Zephyrhills Building Department 5335 8th St. Zephyrhills, FL 33542 Re: Eugene-Residential PV Roof Mount Installation 7638 Merchantville Cir. Zephyrhills, FL 33540 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2017 Florida Building Code 6tn Edition, FBC ASCE 7 Min. Design Loads for Buildings&Other Structures Per 2017 FBC,the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V„it) - 160mph 3sec gust, Exposure Category-C The PV System consist of the modules, railing, and connection hardware.The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. l/a" plywood decking and 2"x 4"roof trusses 24" O.C. The roofing, decking,and roof trusses are in good condition.The existing structure will be adequate for supporting the additional PV dead load and wind loads. i The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the Ironridge railing and flashings/attachments.The attachments can be attached up to 72" apart.The mounts should be staggered,where possible,to allow distribution of the design loads evenly to the structure.The mounts shall be installed with a min. 5/16" lag screw with minimum 2-5/16"thread length. i 11111J/// Please see attached documents and contact me should you have any que�t+i�i�sl. Sincerely, .Z� ® -'%CEAIS••O �i�� D. Chad Godwin, PE 81360 ®' y .81 ; Exp. 02/28/2021 _ ST OF fi4 O ID P MAL �/Inllll� jr3�� i BUILDING DESIGN PROPERTIES SYMBOL VALUE UNIT BASIC WIND SPEED V 140 I mph Figure 26.5-1C,page 249a ROOF PITCH e >7 to 27 degrees MEAN ROOF HEIGHT h 15 ' ft ROOF SETBACK a 3 ft ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE 1 1.00 Figure 30.5-1,pg 347 TOPIGRAPHICAL FACTOR K 1 Figure 26.8-1,pg 252 EXPOSURE g �� EFFECTIVE WIND AREA 1p sf ZONE1 ZONE2 ZONE3 VARIABLE DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT REFERENCE:ASCE 7-10 NET DESIGN WIND PRESSURE(UPLIFT) P„e,313 -32.3 -56.2 -83.1 psf Figure 30.5-1,pg 346 NET DESIGN WIND PRESSURE(DOWN) P-M 20.3 20.3 20.3 psf Figure 30.5-1,pg 346 NET DESIGN WIND PRESSURE(UP) Pie,vv -32.30 -56.20 .83.10psf Calculation:P_u,=hxK„xP_m NET DESIGN WIND PRESSURE(DOWN) Pn.r aDwn 20.30 20.30 20.30 psf Calculation:Pn.t dD,,,n=1,x K.x P,,,m � DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT DEAD LOAD D 3 3 3 psf SNOW LOAD S 0 0 0 psf DESIGN WIND LOAD W -32.30 -56.20 -83.10 psf ASD DESIGN LOAD(UPLIFT) Pd.lgn -22.70 -41.21 -62.05 psf Calculation:Pde,ign=D+SORT(0.6)W(asd) DOWNFORCE CASE 1 Pd.1gn 3 3 3 psf Calculation:Pd,lgn=1.0D+1.0S DOWNFORCE CASE 2 Pd.,* 23.30 23.30 23.30 psf Calculation:Pd�lgn=1.0D+1.0W DOWNFORCE CASE Pd.l.. r 18,23 18,231 psf Calculation:Pd.lgn=1.OD+0.755+0.75W DESIGN FACTORS&CALCULATIONS FOR THE USE OF L-FOOT TO ROOF TRUSS DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT MODULE LENGTH C 5.22 ft MODULE WIDTH B 3.28 ft DESIGN LOAD PER MODULE T -388.34 -705.11 -1061.63 Ibs Calculation:T=Area`W DISTRIBUTED LOAD(UPLIFT) w -59.20 -107.49 -161.83 plf Calculation.w=T/B•2 3r11sP-- DISTRIBUTED LOAD(DOWNFORCE) w 38.21 38.21 38.21 plf Calculation:w=PB/2`A„DD'•,2,z11,p-m RAIL SPAN BETWEEN ANCHORS POINTS L 6 6 4 ft POINT LOAD(UPLIFT) R -355.19 -644.91 -647.34Ibs Calculation:R=PLB/2•" "z`•'sD.,row POINT LOAD(DOWNFORCE) R 229.27 229.27 152.851bs Calculation:R=PLB/2`M,u-2,.ibp - L-FOOT CONNECTED BY LAG SCREW TO ROOF TRUSS/RAFTER Specific Gravity,Rafter G 0.55 0.55 0.55 Table 11.2A,NDS 2005,page 68(Southern Pine) Min.Dia.of Lag Screw,5/16 D 0.3125 0.3125 0.3125 In Pullout Value of W 306.87 306.87 306.87 Ibs/in W=1800 G3/2 Da/4 #of Lag screws 1 1 1 Thread Length Td 2.3125 2.3125 2.3125 In Table L2,NOS 2005 Design Pullout Value per Mount Wt 709.64 709.636 709.636 W,=W•#of Lags`Td SAFTEY FACTOR SF 2.00 1.10 1.10 Calculation:SF=W,/R(Uplift) sl.oa,Drl 1-AuWY (-H-d) , u,ius x.ofmD.sr:eo::I.rrJ,.a,.sr,.rndnr,n�,rNr+aK •r.-11,4o?..,-fgr••,T 1l .hij r+m.+.4D - IMrrnsv m v]k�rcM rev 3D,sp,'1)x+n f.4v,+r4'!nx 1.7,nr]�r.nd.nf NISI.+r 3 ftx-2-YwrNwl kd u„ w9-d-0, Flat hoof Hip R-1(7-<•5 ilry 000 G.bM IIeo1(BS Try G,we Roof(T cis 4f•) � \� In,. o=on., [d Zo n ■ Co..zar., T f.n..�.QYG]OS.N.nv.Dni-[rd IV A.YT.O Mrbwv...Osa./.D.1. 0i, City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: 21- 11-20 . Site: 7 Mer- e Permit Type: Approved w/no comments: Approved w/the below comments: 0 Denied w/the below comments: ❑ This comment sheet shall b -kot with the permit and/or plans. FEB IS 2020 Kalvdiv!Witzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) . - .�,_ .},. I"••3�: .:(.t`,' `;t';:'3:jFYtt'`^ =.(3'„s 1..F.':o E,,1 i liF�?hT£t F'ts: '�€�,,. ^�1:i, vssv. :vi� :'':iii: :�31 t3'^F;f�t-J.3 s3'd ts'� ',i ;s, :-r�r- -,�•�.x.,yf: .{S�' _ '.7' 4. ..SI:3;; t• 'tx?" � �i"%'j;v.t. - 6 A, ,. 1, a 3: •,{�..�". .. .. - � _ §i 4FIUMN; ✓ e' ,.Av'DC'ANk+lt4� 4d{F.N:i� 1 ` `bi5+•. e. ;€',,:=a?,stir L ,•Jr+.r,;�, ar:tj,;•' .. _ ',� a ,•t,: �.� rr.::'a<...`rX..... , '.s ,",':$. i3•.`.::f:;:;+1j-rrt',sn•t t..Th<)_ tit.'' xi n:,:'nt:Jj�:1c( ...;.;tii t}Pi^,!s£C�i t•�i '.aEr i-.a f!;nY: '!v;.e.. f;,+ .fie`'.4'� ^i=.. } ,i:r. .ijitt.w>353SL::tT'?G>x;It,}^'r?'."s3: tliliEi^ jai t;tt,ar. • ;3'=`.§"yf1 hx ':1:�'?'„€Lx'l ¢'>;i$F:s E..°:?'.:S1f°;- +!5.i r `a'`:' �p - .}-T'.'@"i'7' >,¢>gc,x3'.x'F` u.;3?^a ''`'."1;. .,»a a:�t:,•^ 54:T5rs {S d.Q ::::<'ri'°t_> ,»,.�. N`x�,"•aK. s`z'r 1.<'r�'>.. r��r.�»:."..�. +,i»F�'?' L ,t 9c5: x;•1z ^�-a>+..�.. s..,.,.. :...�'�iAa., ..,.,.r3i'%:i':::..;'�' _�.:$:,.,.. ;:t" .:Ti�a-;"(=,;. .w ,_,..,....,.:3•_:.' ° �".c,.> ��«.,v"b....t o�'«=«a::�"F:,z3:¢:�'.«.'z'.>._.._. �rr..�>...r^..m.-• •:,»>n-�-.. µme- YJ.hr da x, . ^�. /max -` w4 <�' 7 .. _ ... €Sf .. `.E�El:�•E, .,tYl�i'. .. :�".l , a i g'T ,.:s�i!:., ;r.:;'9'�„7it'i£'•,c£ii:,,. v€�i75��;.1":':,;Vt� 'e J:':f;�:_ ..aE{i:?i:';cry;+�v ,..i r' " �i•'.... , .!h€ttt:!,tr+:...:fs.^•3.=,:{"'r.,a[E[:u,�r t E N +T,RO _, . No, ✓�'%'a-'}A.�zi�_ fix--�i'•. �:�:.;;�':7tisy:`..'v �a.:']� �"°`„.�j�`�'�. ✓� i& .e'.'>pp'33%����5. > �1"�...•;N;.. .,ii'":Le�r.... =l.St .:, s :1.''lis Fi.i.s�E^7�:.i ... i!'Z.�:i Msa i',�w., ':L'.�ut• :7P �){,r;[:?$ :'31n+�'- :f3. ii i':C L!.'f;.':" :'11::;: Y £° R, ^ a ffs 3 VP • < < � l . } s ..v,omc },}f..,..„xc.;::„:ix yt:n�gr: ..ss s x< £• ., s t ; I -.P>}a ;,i:3:,n.>triatr.,..«f hW"t}":u?v. .� .. ka�, ., ;}: .,'•r.t ,; ,...,,_.. ' FSCt-tiY,ra'=�..='*„�<'�`x` �i.='.:.':.�„e.4rz?.;;�`,:% "s.�4�✓'...:."::v.:u.:v�`�+"..�,.�i.C""',r�'�.rT:�:. o�.,N"xs'w.+"' �1 .. wer , V'MiZerl. , 00 gg�ry ��qq J pry �y q�y �y II'".. '2 J P3,4� f P370 P O J� i`405, P50 F: , Y �m 4 PV power~ optimization at the Module-level Specifically designed to work with SolarEdge Fist i€istallation with a single belt iYiut�ft,L'f5 if next generation inaintenanc€.;with i odole- 4' Up to 25%inure unergy level monitoring aaiperi€i efficiency izJ .z`:r; I Meet,,;l F.0 requirements for arc fault protection (AF(I)and Photovoltaic Rapid v Mitigate's all types of nodule mismatch losses, Shutdov,n System (PVRSS) from manufacturing tolerance to partial shading to ociu le-level voltage shutdown for installer and fireflahter safety Flexible system design for maximum space utilization i Power e Optimizer For North America P320 P340 / P370 / P400 / P4051 P505 b a bb a b bt e r1- '1 9320 (for bigbep. O 0002 (for hi Module .b ee a ee b eoll current e n ad and 4),W11 x •• ♦s ee = r, k,'}>}:;c'•;.^.•?'irs4'f�`;'s'dl'r•' _.. _. _ .. _kE..... x d ;i. 66 TI>il1 CiLIR3NG C3I EiiATIZl7d(POWER: TI{ I hI R.CQN CTEC1.fp.ON£iA7S1VG.5t3LAR�GG Tt lbER7EEt)' r' OtJTF YT-D��k? (a 5�illi DKY(PC7WER PRTIMVER*31SCCyN EC7:Ef?Pf20tvi SOLAf pCt INVERTER QRSQLAFkEDGE l� I�+ltRTER AEE} . :. STANDARD';CMPt3asP�ECE _ � , igr": 9$L h , i.JtJ:t }({•!+.;'!}{t}'9;i�.3S:{9 c.::.".:s'!;7i.� iti :;r4 INSTALLATION SPECIFICA,IIONS , , :..,,....,.-• yr, a -� Y i,x 5! :.Y,_ - ::.sq;i{a,•r:A irx5.::i. �j t}'!£.:„yj, .... .e. _. .. .,'a%_fit. ,. ::}'iitYii Ti" ::Y;>..:i:9• __ .i1?:d >'Rti`it<`tz .. .'C..'.`r'_. , rr, �:F�`�FP:•, <.. ...,. .. r.�.�:a c :4.>. �•t.:i„i:'"�i7, .,„ ,. ..�.irn,a ,«.^•Li ..i 9>.'„•r..:.it;'. .• _. .3::a�:r'i ,. 'G,.'9:, •#;`: , •a3;�.. ;r'r.;:'. :Se of a'"• "3r.,- .. 'r,::.r�a:zy.J, _ .. .s?,ra<lF e.- :nJ i. T x'2:' .>x v .>, •'( ., ri 9r..-r , ,ra�.r51k.rn f ,..y„�t P r a b. + sr i .. _.................. . _. 9.L:ttliS✓"��il:rN,"y Y.N;?'{j}}� ;t; �(f% r.x•'< r '(•-,ic?:iGF':93ai.::}. ,.<fr>.R:< 'e>3.:7i?i:i:}:;.'.,l.u,; ,?.r�',q,r:'r.. ..x`?P,:L;lbx:$.P:i_ ..,.:32;ST A-r.x(Iir' .,},, -rG4+ ;ii>i::�'4.r,fi,ra z?i;:�4eir,•i- .., .,(>�si ,. _ ...- .. ..r.. ,. -. ..i}v:" .,,•te•,. ii'.<,.�a>..°:y'..., vR!a2tL"3`3e=it:.>;+'.<;aft-ai`..9Li>•r9^94,�14•'•4�Y,:i>7tiEi: :.. '`}kr±:b+t4:e, 't7`.'3'"9 it3P 1`R r;?�i3Ge,tll'V:ti , I;ffq C'4L'7'<i}0<•l.e{xix,£"i6^td i<-A,-;"a I C�ilu Y'fa<..E. avn,.x,+saax4Yl dp rp ru.. tsa;Fnrs.ts4✓a-.'>'i;ei,:.<rr,.-.•.�t+ate..w..,:7pr>•,•:<(?.fi NAM i<fJm IG:tu^:tx;t>, � Interic3t i i 3.56. � , `r .ram is .�:•-` �xa 'L 00 -6Sr SS • r , S ..:t t,. f. .ar va ,.• - ✓ :Cx •=f •i Y ;��•,�,�-may' �a v fir .. }f -M y : s s' '}�. ✓�J , �t'..may �'.7j.�:�••��. n �r`✓� .. .. .Yr`t MEW fin :•} .. - s'+'.w�;is�K'.:v'd:�w,.-;1'.'I::�.Y;..:,. x ti:. .!£ .v: 4�•' oe•,�y� , ... 'r. ,..X'.w•. f", t. ,.....:..:..,.y,.f..-. •'fin _ ,..:•:sir. 0 2M PSmM dgeas h=-Ah raft .visit 1e wwirw @ R Y)fA-or.ca installation Tools Required:tape measure,c3 k fire,sK41'�;s�t hex socket - ' f 1 ` . cte: xe3S and snap. 'f}rr .an crzc3 ;3xts.,, .. 1: ,gr ,T3 - e' to mark flas{�rs['�: ions: ? 11, 1 r fi', s, o >i ri 3 : / "'a e< r fijjjj�p��,(.{,� �y�� y�y��x /may p. �•}���..,�j�+...� n�yq.} 3�,�+�},,,,��'j,}��{�.,,���___��-��-www���k $7 �JSd.L�S 7SJiXsI •A Sf�+c;E-tL'3 V�i.ti+`P''�T i' .f V�L1i�4'TG W�JS..` .. ii 3.'3,-CR..i$'LVti 3..1�"!,•; ,,..,...," ./ ',•✓'Y` :r`%y �•y•,���'•;'Ji v'; ...<:, '"i4,:.`...,,rch.,7-'.ti•��:-.-.:::«. '<�,.. ;:f`�Cx'A,. ." iA. e - 'I:j° 1� Syr _J�•^'-' ` ��7•r, .ia Aw ..FP"; t ..�:^:X:-i., �sJt ut.. �:T-",'�'».':lrG�*�» r r^'=...A :'?c^`_ ,.3."•�:•-"-. `.,;r�tr;,-•'. - _t'7 -A.'M (R-�Ts�i�+".-�•,�e' �-xw:F.s+{.. :52_ _•s./`.....y i'�",<:'� r.4;e.....`-'�'. •`-`i°-':.irc-r,`�.. .,,..,.,._-.:.,,�:.--r^,:e,�;�a.�,-»'?'„.Ss.,..-vrr..:";.>,..,r s .d;a--.>:_.ry,z."7` ,.2r.Ra:.,r. .�`:�sr-:,n,w:,.Ks3�<�.�.�:a• :,;•:;; ;.'�,x. - yy,,,,,,;;;; ��g,,,.,,,��g.y.y� ��,�,,�:•�.'r�.`�,;q.. .:8.` •u»4?�. »,•�?.. 4-� ky:f .�',-?„�„is',aP�;�..r_«r,;:-^�_7-}v '�`.,.t31;i,EIt:EY"r,L"F."F���%i3i�nti?5'.t"S'�t.R�' «%� �.:'t��` ':a.,C ,�"��f. c^' �i`' ':�w M •�' 'x:, . .,r ..�.... .r. �''S-`�Yx�"• .;�..y3,,7E�.����r :rx-F, ^"i„-r;�• .r n s. .; , _�., fit;. .� - �:,:.'•t i. ` - ,A�r"'.,' e�r•w``•.' •� � tip,.,:,,:. r`! : cif� .y:.°'`„ yy� .+a._ _ ';•% _ "_'.Y:'y"" w:r wM1�.:�Y•:,..Sii�y'r 4.',x�`J .p;; yx.�� � 3S'f y'.�'�i'Su^',^':F}. ,L�*,f � 'F:F. �"w'r'��K�tf':k':, "I 7� ii �IH �`'i: :<,,..•.;. .�%c?.'... .s. aa.�.;t,s:. -;vim,,. T' i' to 0 45$torte$;mac.&H,reo3L reSm�We vr�ccti.E;�n itTga isYsr t .�_ L/f , .:to x a { r Y.: 1✓' ,t,x y. y£�, !•i.x V tF ',• for Nort h Yh America (A U k >w< ^ i .7 F3-US fSE'f(OOOH-U I SE11400 1-US ORION Oft t' „ ,y `• , no o gy x;>3�.: 3- r � 3 j,;: ',i f,'r�•,<<�'..y;.�., f �'' .,.w�. � .w.0.,at � r .„"' ,.>3x ;}i 2',� a»»..4.� .,....._,.sa,..�.a "M'^�"»'"„s�' ...._....'r' l.wik.....<,.,�.....,,�....: t?1'.JG�"?.C✓v' z _ :. z > x rL�w rz- szte 'f:a s. F a h0, >•°�;f �„^ `'i��.:r'` •P ��yy {�r gg�� '�: 'fix` t •2 ,,.,.>v_..� .'>... .�R....,, .., ,...,.=.n,.. ,v,..H..x�: .g• �m^'ta.^.C;at'. -.Cti:F ,� :g ., gc 4 ' 'r., �c,e. 3,'�.�'a'. '.� . s��.�„ •,-` � ix m+&z{<,�".i..efx a1'r`� ..k.. � �:�- iz f _.3 ........,,.....„,.._.. .;.q .. ,-.l:v,.,•,,;>�:,.r^..^L: ..r._ _ -ux.i' ..xtf "D<c�" va':p i .. ....._....___......,.__....._.......,..„.-,..._._». �.._._,...._..............._.. ..._. .... , 4 - S Y F. `_it-.:;$`x -��a e;; •'�w1.s. .:i:°: ip,''a K;.T1 ��bAf' 1 ,.r.., �`;;?t.' C:s:h`„a,;; s�-rr^'•, s , „ ,x,..a,•.^ .:z.,.'.:,...•2.,:-,,-,,.,.,,�m>,...,,,,<.,.,rxz:',.^•s>�"_ ' d >�;Wh��,<'k•',:�Fa,A^AP ,��a��••'rof l' r '�S # ':.?z,:'z'.at.y'z _`:_1.S:_:a._ro:_'xf n_^�i%iCm y'..n1's..-._";',`i _µ.,,.•uX'€___.. i.�;�, .»_.,.,._,""_,»....,.... ...^�....»...._._..-�_ ......,.,............. _..............^" E ,.< "'.<"Vf-m"��{':via a?' .. ,:.?:r,•,x;,e'^� -t ��'�sR"' r"E"�' '�,,,' "-� -�sa.��s>`ra^!C:a,>c>,:YZM.',e.^ l ,_. .«.....,._.,.._.....__...,..,,»..._..._ .»,»__.,_ ....__.....,_..._.______..,..._..T _ ��_...•�. 'a y � •,:r�ai, ;T `i�a;w"'TMaMA cif ;'et�y^„w>f-�. ,v,,. �'D x�, .'�'� _...,..._...,.,,-,.,..--.. .,.....,,,.._.._.,,.._,.,.___..,..,. _..<.._..__.,...___..«.._✓C...,...,,._ . . ._...,,s•.a:,<" a. 1.� ;.. ,w•�s;� as �, f<.,,r,... «,r.��`<...�, >v !k'�t� $ ` .x ...: ; ... �s-az s.t •- < .:>� .r,a `$' n''"�k .....,..,., „.,'..,*'s^' .'..,-F -.�•.<:` ^_,..-,r-.. 9 1: .. 4w'ra.^,xx";a,"ras-,ai.r,'2 ...:,-.,---.i.._....,_-_•-_...--�+ _.__._.�. _.. <. _ _rna'p ,,..ta,.^<r .!.>a „e,,f,.a,,,a as•„ - _ _...._.._..___..z._._...._..»., m k. ..,; ., _ ".•,a�. .:,s;: ;i - _..fix..tia•_ ,..=.'F�<.,<�:.•" � .�.._,. >.,a,} a 'k.,.,...<. 'ay,raa+rs„::ifr3x: t { ;De� ;>•'rxR4i s..,-.`. ,• ar Sk,.B'k1'}.�V;y.., ,Y4a;`� ,:sFx,�' .r*.:•�,^� 1F ' , x > t i.. .�.., " <,a .<:a� s.� a:`a„ :. .is d=<+ >^r r�sx ::€-','�,ct" tBi T>�'e^cG'K•:+�' _ .,,.,-_,,..,..__...,_.._.._ ....»-,,.._._....,. -"-„i§-.—'^ j �3 3T:<d5 f ,."' :,^r -'^v a. um.�� ., r., :• ,t, of ..... „» P yL , ..: � :. P,,,., '�f. a..,,.a x„ c::: '� .,u.' nr ., ,.ry "', '.,;, .A,^+.yrY"•;4YwwY m...^'as°.KQ,.. - y .zs 7. -., .. ..... .., _. a • ..... ._. ,-`-. .,. ,.. ..,�,...ar L^'rr+'r""1:2>a.• ' , :.t`,r:xirr�;r~';'•Cze6:l�iC,'�,Tu" -.._._-.,,^--.............._._......w..w:...:,»...,_.".....,...,, ._ _......................... '.",>sas:5?*,i:3z.wx.r�L �:�A'xs �� ... ..»•,• >Mi+n"'S�dd fixa+H:',^:3szn!g,kx'sAL'G'+Y.t�rlr^xa+w,` Li /+�; . installation uuifi HD- tae:technology - _ q. CS�2v yam'. •' : ..:�"�< .: ,>.;_.-.,.. '.' .""•'�w;�,4 `r�f3�1CT-vd�s r'�kE.�.E���bi.., ':,.,., .,..::��•,�':.�..,;",k., ':tea`'si1..` .�i,:j:r ,...._._.,',,y.',,,'r«.,--..,,''':-s>'.�+y,' .,,:-- .>: § B Spedic*designed W atork eti'S.im ,s"rni22r5 - - --- -' --— - - — — — _ A _ •rlt�iesmtrduT,e"fec:'a�rRr:se�Oxin 8 '�Y��P, j ..;.,�: ,:�.:',''>'-":;-.::..; .::»w-_:,,�.�;,_, .�-�..,...,....,,.. , d Retord•Evrtzi<inger5trtmc/ t�' y FbwdVsttacteisss€wrvtonger.s;rirgs l Outdw,and indoor insEail.'Lon crru�c su�sr�.a�� re � L r ,s�'&�x� "_ _.,. _ i xa•a r< ss<a rF ESace;^at'tt�:'m"eJ:mx.'F: I •t• ` :«kn ! trefegrafeA gtc fauSt pZsftct a a and its 5htttdounti foa q tioreaJ'R<venua tgrzde data,ANSI s'ti :� Y�s t eYBr ar&xaVa ___._, NEC 2llband2t117.f32t' rf;mda a9Qt2 05fEk5YaatryJ: x x L&SBCT(5'2n:e iy'::<"1:,§.rsT'c;4xivre' I ............. ..,,._........,..._.....-.,........... ..._....., ^tir dessw.g};,'�snun;xc,rxc+au.!swf.:5:a"ct3**t � i solar, '�R hyb'x,,a0.'s"A S2at'8�."t.aa�:vc•.¢attm,a^n wk29,w i:+'xx.*r<>Nr R,1'C.o>'�'+:a�.: ^`9 L,'�z".'k^`ci1?utre' f°ds':2:'"ro'a'ra"»w S.i3'.YSscv;3t-'.*'^`r":`W'4-L5;»w}Yr:¢,'Lt,1�1•'+d*% F S£3?s`43L�G'.Ct'NYd Reim r•am='sdv e v :e+H c".;ErY.+Rs € es-A>a:nwcR.�>.x:w�,sw..+�,.-y,. •m«r+;s.'»e.,w.s,e.�az�-e+�,2+a.�aas*`pa+,ram�a,+aa�..Rs>. .� � 1 4 SFS �.y ^• ' �,dc."N 5 Z ,t� �. t9:- Nre.. $ o. . r `�", l� �{.�'� �y.�.�".'' �sga''g',`��+^,��„bran xgy ''yi«.;g �.;:'t�.:x,:::•`.�::,. '�`€ s ��� �'Y9 Eas'. 67rF' a.a I� A ra rat law .$ vX '�• i.W3V ^ 9 V; 1 ca.fw:Y 1 .'• B'`w A„'N+i,)' . .. e .3 a • t . txn rsj �. . x . . w `r^' ;t; d 4 `%fY'; 4r.+$�: ,n.R ��., V "� �.y%�� 4�{wY4e�' � '�..CF,.�4��$ �'r6 i:8.. nt�5 F O NO T Inverter Type: Solaredge PV Panel: (29)Panasonic 325W 3' Access Pathway Racking: Iron Ridge R-2 Total Wattage: 9,425W O Roof Type: Composition Shingles # Modules (9) Wind Load: 7 to 27 Deg Fastener Type: Use 5/16"Dia 5"Lags F Pitch: 22' Sheet Index Azimuth: 90O S-1 Cover Sheet/Se Plan ___ L S-2 Detail T T E-1 One -Line H S-lA Mounting Plan O CODES FLORID L COMPLY WITH PREVAILING A BUILDING CODE, enera otes: NATIONAL ELECTRIC CODE, SolarEdge SE7600H-US Inverter AND THE CITY OF ZEPHYRHILLS located near utility meter U ORDINANCES -SolarEdge P400 Optimizers O are located on roof behind each module. -First responder access maintained and REVIEW DATE FEB , 6" from adjacent roof. E O = ti CITY OF ZEPHYRHI -Wire run from array to connection is 60 feet. PLAN EXAMINER `,����11111111//��� Utility Meter R-1 t� ,•�`���C=G°�`'��, Godwin Engineering and //// ' # Modules (20) ` Qt1,"�GENgE -COGEN Disconnect •,1 " Design,LLC Located adjacent to • O • 1 ; * = 8378 Foxtail Loop Utility meter Pitch• 22 Layout Subject to Change Based on Site Conditions * = Pensacola,FL 32526 -SolarEdge Azimuth 1800 of /4 D. Chad Godwin,PE SE7600H-US : "LOR G%V ?' Chad®godwineng.com Inverter 'j/ $S.'-- I i ACmcSa1LLC System meets the requirements of NFPA 1 2015 Edition,Chapter 11.12 11111 Meets All Editions of Florida Fire Prevention Code 6th Edition Customer Info: 5001 South Florida Ave, Ste 203 Legend ® Chimney Lakeland, FL 33813 ® First responder access 855-577-7999 Satellite Utility Meter O Vent Pipe Represents all Fire Clearance 1st Responder Access T Do p Manley Eugene Date: 1.22.20 l� PV Disconnect LV1 SolarEdge Inverter including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2015 IRC 7638 Merchantville Circle, Drawn b . CW C b 2017 FL Residential Code & FBC ,6th Edition (2015 International Residential Code - 2nd Printing Zephyrhills, FL, hecked 00 modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 33540 Rev Date: International Energy Conservation Code, City of Zephyrhills Code, 2014 National Electric Code. e• Pa g S-1 Compass for Aerial OF hV nR Se XEt 104 Rai] R ' Soar Madub 5/16"a 5"Stainless Steal Lag Bolt .r. Ironridge XR-100 'Ironridge XR-100 General Notes: - L Feet are secured to roof rafters. @ 72" O.C. using 5/16" x 5" stainless Godwin Engineering an steel Lag bolts. 8378 Foxtail Loop ;" \ % - Subject roof has One layer. Pensacola,,FL 32526 - Allpenetrationsr 1 n gG��• . • ae sealed and flashed. c � �, nom •,; A ;• , 4RIDP Roof Section Pitch Roof Rafter and Spacing Overhang Notes: R1-R2 5/12 2x4 @ 240 C 12 Truss 5001 South Florida Ave, Ste 203 Customer Info: p as Designed er ASCE7-10 Inverter Type: Solaredge Lakeland, FL 33813 g PV Panel: (29) Panasonic 325W 855-577-7999 Racking: Iron Ridge Manley Eugene Date: 1.22.20 Total Wattage: 9,425W Drawn b : CW Modules mounted flush to roof Roof Type: Composition Shingles 7638 Merchantville Circle, Checked b : �� Wind Load: 7 to 27 Deg Zephyrhills, FL, Rev #: 00 no higher than 6 above surface. Fastener Type: Use 5/16" Dia 5" Lags 33540 Rev Date: Page: S-2 Equipment list PHOTOVOLTAIC SYSTEM PV: EQUIPPED WITH p Y RAPID SHUTDOWN 1 2 3 0 0 0 1.7 rI ] 8 (29) Panasonic VBHN325KA03 LABELPER NVICE PANELF RRAPID SHUTDOB PANEL OR SERVICE PANQ.FOR RAPID SHUTDOWN_____ riCOMPLIANT SERVICES _ _ _ _ _ (29) SolarEdge Power Optimizer P-400 PHOTO VOLTAIC OISYSTEM f CTU RENT:DC 236ANNECT DC MAX POWER POINT VOLTAGE:400 VDC (1) stri A AI>P1Y to ng of(11) MAX SYSTEM VOLTAGE:480 DC disconnect/inverter -v- -v -_-u--- - ______ - -v- -u--ni (1) string of(18) MAX CIRCUIT CURRENT:15 A[ i r i ri WARNING 1 2 3 0 0 0 r 0 11 ELECTRIC SHOCK HAZARD Inverter: IF GROUND FAULT IS INDICATED ALL _ _ = o o 0 = _ (1) SolarEdge SE7600H-US CONDUCTORS MAY BE LLY GROUNDED NGRO UNGROUNDED Apply to Inverter SolarEdge AC/DC Safety Switch AND ENERGIZED WARNING ELECTRIC SHOCK HAZARD Power Optimizer AC Disconnect: DO NOT TOUCH TERMINALS Apply to Disconnects Solari 60A Disconnect TERMINALS ON BOTH THE LINE AND Typ LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION All wiring to meet the 2014 NEC and ELECTRIC SHOCK HAZARD Apply to each J box,combiner 2015 Energy Code THE DC CONDUCTORS OF THIS box, disconnect,and device where PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE energized, ungrounded circuits ENERGIZED maybe exposed during service. WARNING (4)#10 AWG Wire SOURCES UTILITY POWER SUPPLY GRIDANDPV Apply to MSP (1)#8 EGC SOLAR ELECTRIC SYSTEM In 3/4"EMT typ or • • • FMC,PVC,LFNC • '' Main Distribution Panel Apply to Disconnects (depending on route to ' ' ' • A 200A Main inv.Metal if interior) L1 L2N Line Side Inverter Output Ckt SolarEdge Inverter Tap M Godwin Engineering an To Overcurrent Protection Device SE7600H-US 32° Design,LLC ��� O,•'�,\CEIy$-���/ice AC Max Output Current 32 w/Integrated Disconnect 60A Service Rated 8378 Foxtail Loop � Z AC Max Ou ut Current* 1.25% 40 _ Fused Disconnect Pensacola, FL 32526 ' ' f Overcurrent Protection A 40 = _ ,�, Neutral to Ground Bd "D No. of Current Ca in Cond <4 AC DaoAanecton D!}•�pC�h�Sd GodwtII, PE 0'. Manual Disconnect Chad@godwineng.com Conductor Gau e AWG 8 Fus i�s�=20 ,.C., N Refer to NEC 312.8 for Conditions on taps in switc J and over current devices GrouLr ITI nd Enclosures. �� [f the conditions are not #6 L 1,L2 & neutral nr to beh osta l d c sar tc #8 L1,L2 & neutral In @ least 3/4" Conduit (1N#8AWGEGC&GEC #8 Ground Figure 690.56(C)(1)(a)Label for PV Systems that 5001 South Florida Ave, Ste 203 Shut down the array and the conductors leaving the array In @ least 3/4 Conduit Lakeland, FL 33813 Note: GEC NOTES Customer Info: 855-577-7999 Provide a grounding electrode system for an In Case of Emergency Call -All wiring to meet the 2014 NEC and ungrounded system per 690.47(C)(3). Date: 1.22.20 GEC must be installed per 250.64 ACDC Solar LLC Florida electric codes. Manley Eugene Drawn b CW - GEC must be continuous un-spliced or irreversibly spliced from • : 60A Disconnect inverter to existing service ground system or continuous from the 7638 Merchantville Circle, Checked by : at 855-577-7999 -Type of conduit to be determined arrays to the existing service ground system. Zephyrhills,rhillS FL, Rev #: 00 yI� - If GEC is not continuous from the array to the existing service ground p y on site by contractor. an additional ground system must be provided from the arrays to a 33540 Must be metal if DC ran interior. grounding electrode per 690.47(D) Rev Date: GEC must be min#8 AWG and installed in conduit E-1 f� Page: 1 01_511 1 1 J 711 O 21'_3" 11' 2"- O s O 59'-8" 42'_4" R-1 R-2 31_611 { # Modules (20) # Modules (9) Pitch: 22° Pitch: 22° 5'-3" 17' 8 Azimuth: 180° Azimuth: 90° 14, 9 \��� �N�EC" Q �i Godwin Engineering an � O • c .9<.O �i� Design, LLC 8378 Foxtail 8 Loop Pensacola, FL 32526 D. Chad Godwin, PE ► ',� OP � °F ' ORI ,•' 7 Chad@godwin i •eng.com �� �0-_. 4, I � Splice Barg Max cantilever is 24" as per manufacturer spec. ` Flashings Max56 * i * i AC UFO's 72 Cantilever = (� Max Span )—_72 (�)—_24 Sleeves/End Caps 28 Customer Info: 5001 South Florida Ave, Ste 203 Solardecks 2 Inverter Type: Solaredge Lakeland, FL 33813 Ground Lugs 7 PV Panel: (29) Panasonic 325W 855-577-7999 Racking: Iron Ridge Manley Eugene Date: 1.22.20 Total Wattage: 9,425W 7638 Merchantvi11 Circle Drawn by: CW , { Roof Type: Composition Shingles Checked by: Wind Load: 7 to 27 Deg Zephyrhills, FL, Rev #: 00 Fastener Type: Use 5/16" Dia 5" Lags 33540 Rev Date: Page: S-lA Pwiic -.. HiTo ..- ... ,.�. I z yX ^'�' f _ £ � • R '��'-};r *xJttS- fit::' <..T-T`w,.as } Ng � uses ultra-thin ELECTRICAL SPECIFICATIONS PERF ORMANCE WARRANTY amorphous silicon Layers,TheseTh1ndéttyers teduce losses, :�,►¢ ! resulting in highereñergy.output thnthriventionaL panels. atedPowertpmaal5 325W 320Wf` ,tea n.. s ,k .. .., �'*" 7A•,•r astmimt{'owets tVilmt• a4 21r a E n II M go kB.W M"mum Power Current tlpmi 5 50A S dfldi ., Upan t ircuit=Yettage 76tM11 t #leeK r= r Shah CircuitCurtent itacI 5 94rk 5.8A �� Yi° ttrmttlttature�oe1tiiPmaisk �' •�` � � �,a ' TemperatureCoefficientMc! O17V(C -t1$V!!C r - rnW.. a i► re s='rs+mp$suwmCoettfetent hset axtm+Vót� -= ,- NOCT 44 o^c 44.4° lo pleIMlfk I C.svi MIIltr M` CECi�TCRat6+giT9ntatlyel; 0 a, .' Cell EMk ency I 2i 895 21 r OIMENSU3NS it.uet.stele Sauer.. -4: Maitrtygett�r tg fil4 `V _ r= �,, 41fd+r'w+f�r� iUwrna�a�sa+Me.nMyM• ,.. " ,, '. , , "_. ,,' ' � '<- ';� �►. - are>nlet. - —_ « , r.euar ew r.e.m64rtbn d Watts per F!r t8.03W 1T BVli 5 Y�eGarM eWin.eNwl � tl.:rt.•«:tr..ree.trcat " Maililt�firtS�ett:tr►V$ltagp• '�.� ..� ,� � -- tana..q�a..Ueraa« " SerwC*Fus*Ratio 15A 1*�L wtgar�►et�iti .t I t °iI� - - A A ttlf"sliiT"sn`o:CTie+u'yMeoetw. : .:. ',� r eM"aa'" M€C$ANtCAL SPECIFICATIONS a j odule which= tntemaM Bypass Diodes I 4 ptlss"Dicdei a � erature coefficient �.�` P '�"s._`K tie,s'S{:. _` %'.•w. a!IWy �' { , dNterwa Wtactoafxoik:et " a theticatty desigtte Weight 419t1Allst _ _.. sofa it�l= txWaH mepstorw DNY+S3tr Cable Length.Male/-Ferrate 402/402111020/1020, n. mm At .tswtrr�esrutrl 4 4 •• abitl ' .: twr � «e �,,.=s"t> •.. :. FYMOi0Ut8= r ���> t� _-- Mtllltuh.J Y5 t i'.CAed a a a onneclorType^ I, Mute-Canta48,Type IV tt4C MSIlwsaiiner.4 ati iva tl C _a itS. . .r' Stat{GV�nti�StgNtt:Sttk I �sr�tuww4 25 Year Product and Performance Warranty**, 65.3 ca m,nMfo f sus m, a aptaRa s' , „, :. ,x ,. .-�. y ,w•. .� �« 63,7ra2oZri4.�,[o�IMaIsI Pallet Ot S L W!N �;: ..,• to u, r lndttst leading-.25 ear product workmanship rY . X P p .,: t,ft : «rttti OuatrttyePerPettetFPuUpk4q t ht r $iw, ry Leading and performance warranty is backed by a century � a Quantity per Container ! r172,prs ' P .P- No old-company- anasonic. owes out ut is v x < P dry, r2ttcontatnst f "W xr tlrPEILiI�WtfMtRatllAttl - t �t lrel guaranteed to 90.76%after 25,years,far greater - . , 7.tiD' IIII `'-w•�''� - other . - -,= , ,'-.` tioaew�m� than companies. Operating Conditions&Safety Ratings000 . .. 508 «gip Higherfhct•ency 19.4% Operating Temperature 4O F to t85+F t-40'E Po M rt 4.00 tia0 Sa fety lm t VetgcAYI haUstons tE5 2q0 ,.....__. Of Enables higher pawed output and greater ene. y ��S ..- d w m « c. UL 1703 cuLvNlk tll internalproduction Safety&Rating Certifications ' �and-20 ttte na yields. H17m-provides maxtmurr� for crc. �. 2A0 _._ { { ' 5 your G mtted' p , OL t2G3 Fire Classd;callon y : C mss" .Se current ranee Limited Warranty 25"*Yrs Workmanship aniI Powef OutE ILir ad' f .' ., �_..-_,. .�� ,._.,�.t� , Manu�tunn ccaUb� USA . str e0 70` gL � ,_mss :t 0 30 40 ;a Voltage tV °` Enhanced Fame Design NOT1t5tandaptlestCond�aat ,Airmasst;.5 istad nre:IDUOf! € RtiIur,ce tf ormedat . . _ � L , ICaOhmpkatwa2S CI 9 Ma iliiyfn power of dettvei►F9r guaranW oondittons;please cl:ecit _ i ht � 40 f i t ,. � !� Anew , mm came ncreases durabi i and. tam , n .rn5tdtWttol,need.., red.. ouewe65lte ,:` � � ., ter. 11 _... mar�rtnrecewetwen ,drarlSi: PraAstctwark .t7t tytp .;: r _ . nt st n t e able to handletoads.of u t 54lfOR : � _ . � ,at � re h�being a e a «>h ftlt�n ttstylxs. . � ,; i r ,.. ,#� to year e,.•;.i, s..ex..Y="... ,. „u _ annuM yaa 2 Also,the water drainage system gives rain voter _ -w ,.. - _, .y_,xu . "� .. .�P a,..,Cam., z✓'S 1 - g ,zx .y ,a,:,.: x.:,.y...,;, _ Sat SSt4lranaw wrthlhe4iwtltAe. �s w � x seduces and snow melt a lace to go,reducing water " iii- f _ .a � t-F£... . , - .F P 9 way . 0.70% and soitin ess dirt on the module means more , ica sandf a y .. t. Aa.. more power sunlight getting through to generate power. • - .� . ,_ ,_,� � �HfTa'isilregfxieiedi►adatnarlkoiPatta?r7rrttGeeup-_ Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ bve to ` SE7600H-US / SE10000H-US / SE11400H-US yPhase OUTPUT with Wve a Technology 3800 @ 240V 6000 @ 240V 11400 @ 240V Rated AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA fNiiiEk3800 @ 240V 6000 @ 240V 11400 @ 240V Maximum AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA AC O ut Voltage Min.-Nom.-Max. ��'� (,, ( t ' / cc G ``�'' (211-240-264) ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac S�E 000 -US I S OOH�US I SES000H-US / SE6000H—VS / AC Output Voltage Min.Nom.Max. ✓ Vac 0. ' �QOtir '" ) 1 I400H-US (183 208 229} AC Frequency(Nominal) 59.3-60-60.5m Hz M, Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47,5 A Maximum Continuous Output - 16 24 - - 48.5 A Current @208V GFDI Threshold 1 A uY Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT ' Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less,Ungrounded 1�5 Maximum Input Voltage 480 Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V1A 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208Vm - 9 - 13.5 - - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground Faun Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 240V % g 98.5 @ 208V Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES' Supported Communication Interfaces R5485,Ethernet,ZiigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optionals Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect Optimized installation with HD-Wave technology 2017690'12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCl according to T.I.L.M-07 I Specifically designed to work with I Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) power optimizers Emissions FCC Part 15 Class B I Record-breaking efficiency I Built-in module-level monitoring INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 3/4'minimum/14-6 AWG 3/4'minimum/14-4 AWG Range I Fixed voltage inverter for longer strings I Outdoor and indoor installation DC Input Conduit Size/#of Strings/ 3/4 minimum/1-2 strings/14-6 AWG 3/4'minimum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8/450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ I Integrated arc fault protection and rapid shutdown for I Optional: Revenue grade data,ANSI C12.20 (HxWxD) 1nm NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA I UL1741 SA certified,for CPUC Rule 21 grid Cooling Natural Convection compliance Operating Temperature Range -40 to+140/-25 to+6014(-40'F/-40-C option)w Protection Rating NEMA 4X(Inverter with Safety Switch) For other regional settings please contact SolarEdge support O I =@@ m A higher current source may be used;the inserter will limit its input current to the values stated w Revenue grade inverter P/N:SF�000cli-US000NNC2 Bolaredge.com A For power de-rating infomwtion refer to https!/www.solaredge.com/sitesrdefaulVkleslsL-temperature-demdng-nofie-na.pdf rn-40 version P/N:SEl000rH-US000NNU4 O swr;dam TiChrglOgies,IrK All rghte reserved.soU1REDGE,u,e saarEdge logo,OPr1MED 9Y SOIMFDC.E�tnamtrks«regletarad vedamrb or saer¢rge Tethe7bgiee,MC Aa RoHS / Power Optimizer For North America Power Optimizer P320 / P340 / P370 / P400 / P405 / P505 Fcr North America, ti zo P ' r aF P400 / P405/ P505 fl, Rated Input DC Powerw 320 340 370 400 405 505 W Absolute Maximum Input Voltage 48 60 80 125w 830 Vdc Mc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-83 Vdc ___________ Q __________________________________________________ _______________ yq imum Short Circuit Current 11 10.7 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II 9 re9 rY Ii OUTPUT DURING OPERATION(POWER E?Pt1Gi 1ZECNNECTEDTOÔPERA17NG OtAAEDGE.INVERi'ER� Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc ..- n= FEWER OPTIMIZER E - R OUTPUT DURING STANDBY( bsld ,lf IIEQ INVE RTEIt OFF'l - - - r s Safety Output Voltage per 1±0.1 Vic r a Power Optimizer - STANDARD Gt?MPUAIVCE � � EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 EC62109 1 closes RoHS 1 (class 5 } s -st INSTALLATION SPECIFICATIONS Maximum Allowed System 1000 Voltage • Compatible inverters All SolarEdge Single Phase and Three Phase inverters 129x153x33.5 129x159 x49.5 129 x 162 x 59 Dimensi / /ons(WxLxH) 129x153 x27.5/5.1x6x1.1 5.1x6x1.3 5.1x6.3 x1.9 S.tx6.4x2.3/ mm/in Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb Input Connector MC4w Output Wire Type/Connector Double Insulated;MC4 Output Wire Length 0.95/3.0 12/3.9 m/ft Input Wire Length 0.16/0.52 m/ft Operating Temperature Range -40-+85/-40-+185 'C/'F PV power optimization at the module-level Protection Rating IP68/NEMA6P Relative Humidity 0-100 % N Rated SIC power of the module.Module of up to+5%power tolerance allowed W NEC 2017 requires max input voltage be not more than 80V Spy,�yf,,,,41l designed towotic with SolarEdge M Fast installation with a single bolt r°For otherconnectortypes please contact SdarEdge l vartets I Next generation maintenance with module- Up to 2 %more energy level monitoring P320,P340,P370, Minimum String Length P400 8 10 18 It Supet'ior efficient(99:5%) I Meets NEC requirements for atc fault (Power Optimizers) P405/P505 6 8 14 protection(AFCI)and Photovoltaic Rapid Maximum String Length 25 25 50 I Mitigates 10 ga types of module mismatch losses, Shutdown System(PVRSS) (Power o imizers) from fanufactunn' toletance to partial5700(60-5114 5250 6000m 1275010 W . Maximum Power per String 5E7600-US SE11400- shading I Module-level voltage shutdown for Installer Parallel Strings of Difrerent Lengths US) and firefighter safety or Orientations r�s It flexible design for maximum space w For detailed sting sizing information refer to:httpi/www.sdaredgecore/sites/defauh/fiks WN-slzln9_na.pdf lttlliZdtt•�3Tf 61 It is not allowed more mix 30 5/P505 with P320/P340/P370/P400 in one string as thingoptimizers does not meet NEC rapid shutdown requirementz safely voltage will be above the 30V requirement ! m For SE14.4KUS/SE43.2KUS:It is allowed to install up to 6,500W per thin]when 3 strings are connected to the Inverter(3 strings per unit for 5E43.2KU5)and when the maximum power difference between the strings is up to 1,00aw e For SE30KU5/SE333KUS/SE66.6KUS/SE100KUS:It is allowed to install up to 15,000W per string when 3 strung are connected to the inverter(3 strings per unit for SE66.6KU5/SE'b0KUS) and when the maximum power difference between the things is up to 2,00(1W solaredge.com so l a r - w C SciarEdge dogles[tolls ,r, =of the s Dr s« are tra .a,., t,a d= .,max r,.� of oth C E ROHS er trademals mentioned herein are tradenwds of thpr regrective wenre.oatc UI2011 V1die G Purrs Si, dto driegewXMrrt notice. /lr IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. - Over their lifetime,solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels fro n a root,and snowfalls weighing i enough to buckle a panel frame. ` XR Rails are the tructural backbone preventing _ _ — these results.Th y resist uplift, protect XR10 XR10o XR1000 against buckling rid safely and efficiently XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1 000 is a heavyweight among transfer loads into the building structure. rail,designed for regions with light or mounting rail.it supports a range of solar mounting rails.It's built to handle Their superior sp nning capability no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans up to 12 requires fewer ro I attachments, remaining light and economical. maximizing spans up to 8 feet. feet for commercial applications. reducing the num er of roof -- • 6'spanning capability • 8'spanning capability • 12'spanning capability penetrations and a amount Moderate load capability • Heavy load capability • Extreme load capability of installation tiro . # Clear lInternalr&black anodized " black anodized finish • clear anodzed finish spices available • Internal spaces available Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. . �I -I Force-Stabilizing Curve 1Q Sloped roofs generate both vertical and lateral 120 forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails I�One is_.specially_designed to increase strength in both 1W directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. 10-20 140 10 .x I 100- 30 { XR Rails are frooR e offers6000-series _ �0 . Compatiblewith Flat&"Pitched Roofs Cl rrosio are made Mat als mpalIbIswith • a range of tilt leg aluminum slay,then protected with an t# 160 FIahFaot and options for flat anodized finish.Anodizing prevents surface other pitched hoof I roof mounting and structural corrosion,while also proving 5070 160} attachments. applications, a more attractive appearance. 80-90 160;"a