Loading...
HomeMy WebLinkAbout20-22572 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22572 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:22572 Issued: 3/04/2020 Address: 7987 SAIL CLOVER LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 266,079.30 Total Fees: 19,551.25 Subdivision: ZEPHYR LAKES Amount Paid: 19,551.25 Date Paid: 3/04/2020 Parcel Number: 35-25-21-0140-00700-0080 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE, FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,362 SQ FT APPLICATION FEES PLUMBING FEE 206.25 SEWER CONNECTION RESIDEW 2,090.00 ELECTRICAL FEE 309.38 WATER CONNECTION RESIDENI 1,010.00 IRRIGATION METER 473.78 MECHANICAL FEE 144.38 SCHOOL IMPACT FEE-sfr/1% 83.28 SCHOOL IMPACT FEE-sfr/100% 8,328.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,477.49 PARK FEES SF 769.56 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 WATER METER RES 3/4" 473.78 I �-+ Inspections Required FOOTER 2 D ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete PlanF Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#2020030309 OR BK 10056 PG 3245 Page 1 of 1 Y 02120/2020 01:15 PM Rcpt:2137382 Rec:10.00 DS:0.00 IT:0.00 �_..; Nikki Alvarez-Sowles, Esq., Pasco County Clerk&Comptroller Permit No. Parcel ID No --2s- Ds-off r-)mo `MIM-+O$d NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Comm ncament: 1. Description of Properly: Parcel Identification No, $ � C& _ —I _ n 1�4C_ -en-so o2el iIdx � Ckpyex Laky_ & r—, Street Address: �!3� 2. General Description of Improvement New Singe Family Residence 3. Owner information or Lessee information if the Lessee contracted for the improvement: D.R. Horton. Inc Name 12609 TaIall DrfvP Tampa 33637 Address City state Interest in Property: Fee Simple Name of Fee Simple Titleholder. (If different from Owner listed above) _ Address city State 4. Contractor. D.R. Horton, Inc Name 1602 Telecom Drive Tampa 33637 FL Address City State Contractor's Telephone No.: 6. surety: _NIA Name Address ctty State Amount of Band: g N/A Telephone No.: S. Lender. NIA Name Address City state Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: David Gude Name 12602 TelecoM Drive Tampa 33637 FL Address City State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,fhe owner designates NIA of to receive a copy of the Lienoes Notice as provided in Section 713.13(1)(b),Florida statutes. Telephone Number of Person or Entity designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): I WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EKPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713 PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing otice f commencement and that the facts stated therein are true to the best of my knowledge and belief, STATE OF FLORIDA COUNTY OF PASCQ Stg ture Owner or Lessee,or Owner's or Lessee's Authorized Officer/DirectorlPartner[Manager _Assistant Secretarv/D.R. Hotto0. Inc Signatory's Title/Office, un The foregoing instrument was acknowledged before me this day of�e 7 20 2g by asSecretary (type of authority,e.g.,officer,trustee,attomey-in fact)for D.R. Horton. Inc (name of party on behalf of whom Instrument was executed), Personally Known C4 ORProduced lder>Ufication ElNotary Signature CO..nM1.,_ ..� Type of identification Produced Name(Print) �" �,,iR „Uh'. �:�:V:y„1,('/1 ".:.'.,r'.Tit; N •:1 hPY Rye Notaty Public •5t�+t8 ;t i tr,t,d '_``raj DANA ANNE +w ' Commission >ti G6 010660 Notary pL " aa:3� ht Comm.Expires Jul 12,2020 4, ,'�',. T Ga blic-71YAGHTIrit of Florida °;..•,, y P A�- <e� rmmission Q1t c'"'m'Fxpr60 12,2Q20 wpdatalbcslnottoecommencement_ptO53048 D.R. Horton-7987 Sail Clover Lane-2,362 sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 1,375.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,477.50 ELECTRICAL: $ 309.38 PLUMBING: $ 206.25 MECHANICAL: $ 144.38 SUB-TOTAL $ 2,137.50 TOTAL $ 2,137.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ 473.78 FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,738.41 PARK IMPACT FEES $ 769.56 SIF'S: $ 8,328.00 100.0% $ 8,328.00 1.0% $ 83.28 TOTAL: $ 8,411.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 19,551.25 35-25-21-0140-00700-0080 1 Pasco County Property Appraiser Page 1 of 1 Parcel ID 35-25-21-0140-00700-0080 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $0 TEMPLE TERRACE, FL 33637-0935 Building $0 Extra Features $0 Physical Address 7987 SAIL CLOVER LANE, ZEPHYRHILLS, FL 33541 ]ust Value $0 Assessed $0 Legal Description (First 200 characters) Non-School Taxable Value $0 ZEPHYR LAKES SUBDIVISION PHASES 1A 2A 2B &4A BLOCK 7 School District Taxable Value $0 LOT 8 ]urisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) _ Line Use Code Description IZoningunits Type e --ICondition/alue 1 0000V� Pric --- Unknown Vacant 0.00 AC ;$13,190.00, 1.00 $0 Additional Land Information Acres Tax Area FEMA Code_ Res Code i Com Code Condo Code 0.00 30ZL _ -- 3ZHN 3ZHN — 3ZHN Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) Line Code Description Year Units V lua e No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page —� Type DOR Code Condition Amount _02/2020 10055 / 1634 _ Warranty Deed 05 _Vacant $782,800_ 09/2011 8606 / 3376 Warranty Deed 05 _ Vacant —_$0 06/2010 _ 8360 / 1872 Certificate of Title 12 _Vacant ;� $0 06/2006 7017 / 0395 Quit Claim Deed Improved $0 05/2006 ]v 7026 / 0555 Warranty Deed Improved $0 05/2006 I 7002 / 1637 Quit Claim Deed Improved $0 https://search.pascopa.com/parcel.aspx?parcel=2125350140007000080 3/4/2020 PASDO COUNTY, FLORIDA Permit No. 22�5'"Tz �) Data Permitted 't Builder Name/OWnef Name s( ) �k7Y1 Control County Parcel No. 3.5-��Z(-bit �7CY�-($�}�� Subpiv: I' Address/Location 7?62 cSAr- K !� t r Classiflcationfrype of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: pZ- Exempt ❑-(es ❑ No How Determined �w / Impact Fee Amount $. 3,I�J�� Zone No. TAZ: y' SCHOOL IMPACT FEE Account (056) Single=Family Detached House Amount (057) Moblle Home (058) Other Residential 123) Collection Fee Exempt n Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 761. Exempt ❑Yes ❑ No How Determined. LIBRARY FEE Land Accounf Land Credit Land Total r Facility Account Facility Credit Facility Total Exempt n Yes ❑ No How Determined Total Amouttv_& RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION A PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE c SEEN PAID.AND .. . !'. RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but slmply recalpt,of.a copy of.this Form,placing �? the building permit owner.on notice of this assessment and the conditlons of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 1 uv-uv4u City of Zephyrhills Permit ermit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting Owner's Name nc- J Owner Phone Number Owner's Address 3S Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS Sa_%I C, ley tav-,ZQ A 335-1() LOT# SUBDIVISION (-bcl,��;;,4ARcELID 0 0 G­_�00 -WS 6 TDO13 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR E� ADD/ALT SIGN DEMOLISH' INSTALL REPAIR. PROPOSED USE O SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK , J BUILDING SIZE F SQ FOOTAGE[I��(,2 P_ HEIGHT =BUJI DING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING 1$ 1 [MECHANICAL ' $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY U OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA OYES NO 0 41-46.1-41- - - - - - - - - - - - - - - - - - - - - - - - - BUILDER COMPANY • SIGNATURE REGISTERED FEE CURREN Address License# Ea ELECTRICIAN COMPANY 3IGNATURE Zr REGISTERED '?/ N- -I' FEE CURREN, Y/N Address Ji 5L I License# c,13 o osa 'LUMBER COMPANY -S t:: R o I n� I(\ 3IGNATURE 5 REGISTERED Y/ N FEE L21 N Address 7L-51b ido) S-�,t /0M License#T—Cp7o�Z:;' )3 UIECHANICAL COMPANY 0m3i"\ik B;r 3IGNATURE REGISTERED Y/'N FtECURREN,\J I Y/N Address 1'510'- D>S4y- 4- kk3 9jr, 3q�o License# )THER C1 ofs, & / COMPANY r-ti Ck arvia I �0 3IGNATURE Y1 N FEE CURREN Y/N Address ts� wew PA+&�td' 3 ( S-31 License# I cc I I I I It III .1111ill,011 III I [ I Ili Ili it ZESIDENTIAL Attach(2)Plot Plans-,"(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&I dumpster;'Site Work Permit for subdivisions/large projects ITS Permit for n ew construction. 'OMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety'Page;(1)set of Energy'For .R- Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirbments'must meet compliance' 'IGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . v v )Irections: - -■ -■ -■ - -•- Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) k Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing' same. )VER THE COUNTER PERMITTING (copy of contract required) Leroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage} Driveways-Not over Counter if on public roadways..needs ROW' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more reathctiva'than County regulations. The undersigned assumes responsibility for compliance with any oppUuab|edeedreathut�no. ' UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or oontroctora.to undertake vvork, they may be required to be |ioannad in accordance with state and |000| regulations. If the contractor is not licensed as.required by |avv. both the owner and contractor may be cited for o misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the ' intended vvork, they are advised to contact the Pasco County Building Inspection Division—Licensing,Section at 727-847- 8009. Furthernnore, if the owner has hired o contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application forvvhiuh they will be responsible. If you, as the owner sign as the contractor, that may baon indication that he {a notpropedy]ioenned and is not entitled to permitting privileges in Pasco County. TRANSPORTATION |K8PAGTIUTILIT}EG IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the conatruot|nn of new bui|dinge, change of use in existing buildings, or expansion of existing bui|dinga, as specified in Pasco County Ordinance number 89-07and 90-07. as amended. The undersigned also underatonds, that such fees, as may be due' will be identified at the time of permitting. It is further understood that Transportation Impact Feeo'ond Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" or final power release. If the project does-not involve a certificate of occupancy or final povverre|eoue, the fees must be paid prior to permit issuance. Furthermore, if Pasco County VVaterlSavver Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713. Florida Statutes, ao amended): If valuation nf work ia $2.5OO.00ormore, | certify that |' the opp|ioant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and ,Connurner Affairs. if the applicant is someoneotherthenthe"ovvner'' | ue�ifvthat | haveobtoinadaoopyofthenboved�mcribaddocunnontaDdpronniaeingoodfeithto deliver ittu the"ovvner"prior bocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable \avve regulating conotnuotion, zoning and land development. Application is hereby mode to obtain a permit to do work and installation an indicated, | certify that no work or installation has commenced prior to issuance of a perMnit and that all work will be performed to meet standards of all \avvo regulating construction, County and City codes, zoning nagu\abnno. and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply tothe intended work, 'and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: ' Department ofEnvironmental Protection-Cypress Bayheado, Wetland Areas and Environmentally Sensitive Lands,VVateU/WaetevvaterTreatment. - Southwest Florida Water Management D|athct-WeUs, Cypress Bayhaada, VVaUend Areas, Altering Watercourses. - Army Corps ofEDgiDears-SeavvaUa, Docks, Navigable Waterways. ' Department of Health 8 Rehabilitative Services/Environmental Health Un|t-VVe||s, Wastewater Treatment, Septic Tanks. ^ - U8 Environmental PnuteotionAgency'Asbaatos abatement. ' Federal Aviation Authority-Flunvvoya. | understand that the following restrictions apply to the use offill: ' Use of fill ia not allowed in Flood Zone"\y' unless expressly permitted. ' \f the fill metahe| is to be used in Hood Zone "A", it is understood that o drainage plan addressing o "compensating volume" will be submitted at time of permitting which is prepared by professional engineer licensed by the State ofFlorida, ' If the fill material is to be used in Flood ZuOa "Y' in connection with o permitted building using otann vva|| construction, | certify that fill will be used only to fill the area within the stem wall. - If fill 0ob*ri8| is to be used in any area, | certify that use of such fill will: not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions ofthe building permit issued under the attached permit application, for lots |eaa than one (1) acre which are elevated by fill, un engineered drainage plan iarequired. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. l understand that separate permit may be required for electrical work, p|umbing, nigOo, vve||a' pools, air onndifion|nA, gaS, or other installations not specifically included in the application. A permit issued ahoU be construed to be a license to proceed with the work and not as authority to violate, oanma|, after, or set aside any provisions of the technical'codes, no[shall issuance of a permit prevent the Building C}ffioie| from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within-six months of permit imouanom, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced, An extension may be naqueoted, in vv[iting, from the Building Official for o period not to exceed ninety /BO\ days and will durnondTede justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. CONTRACTOR OWNER OR AGENT- 71 Subscribed and sworn to(or aff4ed)bqfore me this Subscribed and sworn to(or affirmed)before me this by �keAMR by Who islare personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. _--- Notary Public utarvPubic Comm|no|on Commission No. e s m ed Name of Notary typed,printed or stamped ry ­w�--_State of Florida-Notary Public xpij MY Commission Expires July 12, 20223 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received phone Contact far Permitting E: ..,•Ownees'-Name Owner Phone Number ,;;•:Owner's Address Owner Phone Number Owner Phone Number JOB ADDRESS' LOT# SUBDIVISION PARCEL ID# (OBTAINED,'FROM:PROPERTY TAX,Nt2710E)'. ;WORK PROPOSED . NEW CONSTR, AQD/ALT- . '0 SIGN [� Q rDEMOLiSH e INSTALL. 8 REPAIR PROPOSED USE, 0 SFR 0 COMM OTHER TYPE OF CONSTRUCTION , BLOCK 0 FRAME STEEL Q DESCRIPTION OF.WORK BUILDING,SIZE WFOOTAGE= HEIGHT , . BUILDING $ � VALUATION OF°TOTAL CONSTRUCTION Q£LECTRtCAt. ($ AMP'SERVIC£ DUKE ENERGY' Q W.R:E.C. =PLUMBING $' =MECHANICAL $• VALUATION OF MECHANICAL INSTALLATION =GAS Q ROOFING 0,., .SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS fLO.OasZONE AREA [ ]YES . NO BUILDER COMPANY SIGNATURE REGISTERED Y/•N FEECURREP Y/•N Address License# ELECTRICIAN, COMPANY SIGNATURE REGISTERED" Y/`N FEE CURREh LILN J. Address License#T77- PLUMBER �' } ��- COMPANY SIGNATURE «<...✓J/ REGISTERED Y/=N FEE CUR'RE Address. License.# 1( 7 MECHANICAL .:,, COMPANY SIGNATURE. REGISTERED' Y/ N FEE CURREN " :`.Y/N r Address,. License#. �. OTHER COMPANY- SIGNATURE REGISTERED Y/,N,,,.; FEE,CURRE,K,.-. L Y`/;N:._ Address .License#J. � r.,.. RESIDENTIAL Attach{2}Ptot Plans;{2)'sets ofButli3ing'Plans;.(i).set of Eaergy.Forms;'RO=�N Perrriit.for new cons#ntctton, kt , P , ,Miriimum-.ten-(�10)'Workind.days after-subnmittal`da1e,`l k6iri oinsite,Constrnctiori Plans;Stormwater Plans.w/Silt Fence installed, Sanitary:Facilides kj_,dumpster,,Sife Wark,Permit`forsubdivisions/large-projects` COMMERCIAL Attach(2.)compiete,sets.of..Building Plans;plus,a�Life Safety-Page;(1)setof EnergyForms.R-O�W Permit for.new.construction. Minimum ten,(10),working,days.aftersubmittai date:,Reguired-onsite;Construction:Plansti'Stom7water Pians w/SiltFence installed; Sanitary Facilitres&1 dump§ter.Sife W6W PermiEfor al!new projects.All commercial.requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "'•PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign.back ofapplication,notarized 'if over$2500.a Notice of'Corr.imer!cement is required. (AfC upgrades over$7500) I Agent(for the.contractor)or Power of;Attomey1-for the owner).would be someonewith notarized letter from owner•authorizing same ER THE COUNTER PERMITTING {copy,of contract required) oofs if shingies Sewers Service Upgrades-A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with.any applicable deed restrictions. UNLICENSED CONTRACTORS AND-CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be.required to be licensed in:accordance.with:state.and.local regulations. 'If the contractor is not licensed as required by law, both the owner and contractor:may be cited fora misdemeanor violation under state law. If the owner or intended contractor are uncertain as to.whatlicensing requirements may apply for the intended work, they are advised to contact the Pasco County Building1rispection Divisioh—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired :a contractor or contractors,._he is advised .to, have the contractor(s) sign portions of the "contractor Block" of this.application for which they will-.be-responsible.. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled.to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND:RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and-Recourse-Recovery Fees:may,apply to the.:construction of new buildings, change of use in existing-buildings, or expansion of ez§ting buildings, as specified in Pasco County Ordinance number.89-07 and 90-07, as amended. The undersigned.also understands, that.such fees, as may be due,.will-be identified at the tune of permitting. It is further understood that Tiransportation.lmpact-Fees and Resource Recovery Fees must be paid.prior to receiving.a "certificate of.occupancy"'or final:power release. If the project does-not'involve..a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore;"if Pasco County Water/Sewer Impact fees are due, they must be paid prior to.perm it_issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 71.&Florida Statutes;as-amended): If valuation of work-is,$2,5.00.00 or more, I certify that I, the applicant, have been-provided with a-copy of the-'`Florida-".Construction-Lien Law—Homeowner's Protection Guide" prepared by the Florl&r Department of Agriculture and Consumer Affairs. if the,,applicant.is someone other than the"owner",J certify that 1-have=obtained a copy of-the above-described--document and promise in good faith to deliver it to the"owner".prior to commencement. CONTRACTOR'S/OWNEWS AFFIDAVIT: .I'.certify that all,tfie:info17mation-in.this:application.is accurate.and that all-work will be done in compliance with all applicable laws regulating construction;zoning and land-development.;.Application is hereby made to obtain a permit to':do°work,and installation 'as`indicated: I certify that no work or installation has commenced prior to issuance of a-permit and,that all work will be.performed to meet standards of all laws regulating construction,'County and'City'codes; zoning.-regulations, .and'land`°development regulations in the jurisdiction. I also certify that I understand that the regulations of other:government agencies,may apply-to:the intended work, and that it is my responsibility to identify what actions.I must take to be-in compliance. Such agencies include but are�not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland-Areas.and Environmentally Sensitive -Lands,Water/Wastewater;.Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of:_Health &:'Rehabilitative Services/Environmental Health Unit=Wells, Wastewater Treatment, Septic Tanks - US,Environmental Protection Aoency-Asbestos.abatement. Federal Aviation Authoihty-Runways. I understand.that the,following,restrictions:apply to the use of-fill: Use of fill,is notallowed in`Flood'Zone"V"unless-expressly permitted.. If the fill mater ial.is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"_.will,-be-.submitted at,time,of permitting.-which is,prepared by-a'professional engineer licensed by the State of Florida. If the till material.is to-be.-used.;in -Flood Zone"A".in connection with a permitted building using stem wall construction, I-certify that fill'will tie-used only to filkhe area within the-stem.wall. If fill material is to be used in any area, I certify that use.of such fill will not adversely affect adjacent properties. If use of fill.-is found.to adversely affect adjacent-properties;:the owner may be cited for violating the conditions of,the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated-,by filly an.engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand.that a separate permit,may be,required for electrical-work, plumbing, signs, wells, pools; air conditioning, gas, or other installations not specifically included in the-:application. A permit issued shall be construed to be a license to proceed with.the work and not as authority to violate,cancel,,alter, or . set aside any provisions of the technical codes.-nor shall issuance of a permit prevent the Building Official from thereafter' requiring a correction of errors in plans, construction or violations of any codes. Every permit issued'shall become invalid unless the work,authorized by such-permit is commenced within six months of.permit issuance, or if work authorized-by the permit is suspended or abandoned for a period of six(6)months after the time the.work is commenced. An'extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will:demonstrate justifiable cause for the extension. If work ceases for ninety'(90),consecutive days,the job,is considered abandoned. WARNING TO-OWNER: YOUR FAILURE TO RECORD.A NOTICE-OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO-YOUR PROPERTY. IF:YOU`.INTEND_.TO'OBTAIN FINANCING,:CONSULT WITRYOUR.LENDER:OR AN ATTORNEY'BEFORE RECORDING YO.UR:NOTICE.OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and swom to(or affirmed)before me this Subscribed and swom to(or affirmed)before me this by by Who is/are personally known to me or has/have produced Who Is/are personally.known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 8, BLOCK 7, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 7,451 SQ. FT. Curve Table LIVING AREA = 1,828 SQ. FT. Curve/ Length Radius Delta Chord Bearing Chad GARAGE = 430 SQ. FT. ENTRY = 16 SQ. FT. C1 55.46' 935.00' 327*35" S183352W 56.45' LANAI = 88 SQ. FT. C2 47.87' 758.00' 337'07' N1627'13'E 47.87' PATIO = 0 SQ. FT. DRIVEWAY = 411 SO. FT. C3 333.09' 960.00' 2251'51' N2229'46'E 380.56' A/C PAD = 12 SO. FT. C4 280.82' 960.00' 16.45'37' N2532'53'E 279.82' WALKWAY = 28 SQ. FT. IMPERVIOUS = 38% C5 10227' 960.00'1 6T16'14' N14M6'58-E 102.22' = 2813 SQ. FT. ^y SOD = 4,638 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 739 SO. FT. Z DRIVE APRON = 152 SQ. FT. 1" = 30' 304 PUBLIC S/W = SQ. FT. GR P�HIIC SCALE SOD m 304 SQ. FT. � TOTALS 0 15 30 AREA = 8,190 SQ. FT. / DRIVEWAY = 563 SO. FT. SIDEWALK = 311 SO. FT. PRC / SOD = 4.942 SO. FT. 9g. tOT 7 A. /u) COCk 7 / Cr ' / r &- /cc) t\ .0'V ... -- r /�! is 9 yob .� / nod R _'n•_7 ! N�Z4gSS. ! -/ A u � 25,5" W \ 4i N (41 g9 ��' E e s7• l ! Q / 6 9�2'I h'7 S'D&q f_ 5g e)' ��t� �;•:;.,:.. I 6 � 04 e��k9 zs.S 88 i ! a �o a� h PREPARED FOR: 11•�kHURi'UN'� / rae�a�a s,�ccssc� / BUILDING SETBACKS / FRONT: 20' GARAGE: 25' REAR: 15' SIDE: 5' SIDE STREET: 15' PC NOTES: LEGEND: 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — —•— BUILDING SETBACK LINE PI POINT OF INTERSECTION BASED ON THE APPROVED ENGINEERING PLANS PC POINT OF CURVATURE PREPARED BY HAMILTON ENGINEERING & —- CENTERUNE PT POINT OF TANGENCY SURVEYING INC.. ———— RIGHT OF WAY LINE RP RADIUS POINT PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1985 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES r:-". CONCRETE (P) L PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF ' 0 (C) CALCULATED A/C AIR CONDITIONER PB PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SQ. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY L&WE PRIVATE LANDSCAPE&WALL EASEMENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY DE UE DRAINAGE EASEMENT EASEMENT SEMENT THIS IS A PLOT PLAN ONLY D rAE DRAINAG UTILITY�E&ACCESS EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M.MAP NO. 12101CO293F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED 09/26/20K AND FOUND THE SUBJECT PROPERTY APPEARS TO LAND SHOWN HEREON FOR EASEMENTS, RIGHT UE IN ZONE'X',AREAS DETERMINED TO BE OUTSIDE THE 0.27E ANNUAL OF WAY, RESTRICTIONS OF RECORD WHICH CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO GUARANTEES AS TO MAY AFFECT THE TITLE OR USE OF THE LAND. THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE NORTHEASTERLY LINE A!5flA 3. NOT VALID WITHOUT THE AUTHENTIC OF LOT 8 BLOCK 7 BEING S72'49'55'E,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRON SEAL OF A FLORIDA LICENSED REVISED: A M E FR I C A N SURVEYOR AND MAPPER. (FIELD DATE:) I Digitally signed by James W. SCALE 1' 30 FEET R M E Y I N G +s;:%":'•a, -Boleman ,t$ DN:c—James W.Boleman, APPROVED BY: `� 8-CM A P P I N G INC. f� �U `-American Surveying&Mapping, CERTIFICATION OF OF AUTHORIZATION NUMBER LB/6393 "ti:�.M;y emaihJboIfemanCa=orpate.com,FOR 190901 LOT B.BLOCK 7 3191 MAGUIRE BOULEVARD, SUITE 200 ;;, c=1.15 THE JOB NO. ORLANDO. FLORIDA 32803 Date:2019.12.1114:4556-05'00' FIRM (407) 426-7979 DRAWN BY: DS0 PLOT PLAN 12-10-19 JCM WWWAMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE D Q� N I CJ" A- I n fr Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. .Lots shall be graded to coriiply with R401.3 of the F:B.C. 3. Compaction test required if 24": or more.of fill dirt is brought in at any one place. 4. Tie *in survey required before pouring concrete. .5. Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All,property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.requirements shall be met:.: 9: No electric,.plumbing; mechanical, or.framing shall be:covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances.shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303:4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the E.B.C. 13. Foundation supports for A/C units.shall be raised at least 3" above-finished grade. M1309. 14. Return air in all bedrooms. F.B:C- M16MA 15. Smoke detectors are to be installed in'accordance with R313:1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308:4 of the F.B:C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702:4:2 F;B'.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land_ Development Code,lots shall be sodded before_ final at least 10 feet around the structure. 25: R403.5.3Hot wate- pipe insulation Insulation for hot water. pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping V.inch (19.1 mm)and larger in nominal diameter.- Piping serving more than one dwelling unit. Piping located.outside the conditioned space: Piping from the water heater to:a distribution manifold:. Piping located under a floor slab.. Buried in piping,: Supply and return piping in recirculation systems other than demand recirculation systems: 25. Blower door test shall be provided before C.O. 26.A copy of the enemy cacls shall be with permit at all times 27. CoPP offnal.insulation report shall be provided with permit'before rinal 28 No fence,pool or screen enclosure :is issued with this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code Oh Edition R.O.W.-Right of Way. A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)