Loading...
HomeMy WebLinkAbout20-22606 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22606 BUILDING PERMIT -,,PERMIT INFORMATION LOCATION INFORMATION Permit Number: 22606 Address: 6881 WAGON TRAIL ST Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVERADO Est. Value: Parcel Number: 05-26-21-0100-01200-0110 Improv. Cost: 2,300.00 OWNER INFORMATION' Date Issued: 3/27/2020 Name: PERAZA-SMITH, GEORGE &ADRIEL Total Fees: 82.50 Address: 6881 WAGON TRAIL ST Amount Paid: 82.50 ZEPHYRH ILLS, FL 33541 Date Paid: 3/27/2020 Phone: Work Desc: CONSTRUCT SCRN RM 200 SFT CONTRACTORS APPLICATION FEES ARM ALUMINUM INC BUILDING FEE 82.50 Ins ections Required FOOTER 2 D ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. � �6` / &-- CONTRACTOR SIGNATURE PERMIT OFFICZR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: A # A v km, G Date Received: 0, b,7 O Site: ua Try Pemut,Type: �C�-Q� h ROC>Wl- I Approved Who comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ -&/6 s10114 This nt she t shall be kept with the permit and/or plans. MAR . YwIe Kal ' witzer—Plans Examiner tontractor and/or Homeowner (Required when comments are present) . I 813-78,0-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department pp•� /y`,7 Date Received Phone Contact for Permitting �L7 71 !!i!IEEE /� n y /7/� n ,1ltEit Owner's Name 1'/�,eS C ��C�7 �1 fT�/ Owner Phone Number Owner's Address 8�O �r✓�6Dn/ �'IA�Z Jr Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address �1 • JOB ADDRESS b�O c) WA 0!1' T L SE, 1n1 LOT# SUBDIVISION s1 vVe nto0 I?a PARCEL ID# 0.15' zb -a1 OtloV "01-76V 0111J (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q COMM = OTHER 1.4 L_U1W_I 17J TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK .rCYZf_fA1 flpOM tt BUILDING SIZE I = SCI FOOTAGE zV HEIGHT r -f1C'Irx-M-19 rL1''E�z.. ..r, c-c' C'1CL"'C'z-rCcz'7e'c'�t'c"c-Z'r'CE'c'E'7Criz-C' "C�c ZiZ-rrc-rX'Cc€'r7E'c'i-CSrc-L-Z7 =BUILDING $ �vO VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY Q !y� W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION rr =GAS = ROOFING Q SPECIALTY = OTHER0 FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NOf_�,11540 BUILDER ��� �] COMPANY SIGNATURE REG ry //V�� ISTERED Y/IN FEE CURREN I YIN y Address xi/��6V r4r 4.)00rP License# ` ec ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I icense# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address L License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEECURREN I Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# iitill.1.i[ItliilllllE.Itli[l1111[i[[!ilti[!11li[tiE[1IlitllElii[ litli.7 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal dale.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 1 - 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor Is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or Intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that hens not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 9D-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant Is someone other than the"owner.I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be In compliance.Such agencies Include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/WastewaterTreatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencingconstruction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,P Y q P 9� 9 P 9,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who islare personally known to me or has/have produced Who islare personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped These Standard and Plans meet the ALL WORK SHALL COMPLY WITH PREVAILING SCREENED ENCLOSURE ENGINEERING DESIGN CODES FLORIDA BUILDING CODE, 6th Edition (2017)Florida Building Code NATIONAL ELECTRIC CODE, AND SPECIFICATIONS FOR PERMIT APPROVAL "APPICABLE WIND SPEED ZONE: 14 N THE CITY OFZEPHYRHILLS NANCES JBM&R ENGINEERING, INC. RISK CATEGORY 1 CAN #7457 Aluminum frame of enclosure within 5'of a swimming pool waterline must be bonded per the protocol and PO Box 1566 Valrico,F133595-1566 specifications of the Electrical section of the Florida 813.741.2109(office)813.655.0061(fax) Building Code a3e - zs zzVo®A7teR vo 20 20 Ralph E. Remmert, P.E. 39610 120 Ilu105 ZEp�EIR 10 PAN E)(AMI S for 16 e ARM ALUMINUM >< 150 '1 ls6 2 a 230 e x I P)"" ., r 1 1. -his: are ntlmdo seller 3-wond gust '►+• i�- �- -. • � � 41td ZCCCC if,Milos.per fxur.(y's)at 33 •�� JBM&R Engineering, Inc 3 610 "ct"" �1a * •cis•. 1A0 = POBox 1566 E __ 2- Llh»;r irterralatfaa bet.tea contau•a _ �. et.a. �r Valrico, FI 33595-1566 OF 1 La1,pes.i ca,atal arras ovt.id.the 160 813-741-2109 S E .=�, rat ar of. a ca use the last a;ns apead ��� �carioia•aL tFn�ccastaL rna. -���0 � A. ftuctilin terrain,nwlaa. xam 15 ------ �i, ,(` QR,.•'• vim.` pnaloatcries, and special tdtd.regioea L sag w sM, um - ,''''����•►►�ON�A�t `` S.nlNi 1 sreedsdccarez for trnidto�a=nrfawr.ty ►1f it a 25%probability.ol exieeduce in 5&yaars 160 -- (utnual EKceedWe etabability a d.3[3336 :. MLL r 3"years}. .. � •w as 170 170 . 01 811916a 091111� _ PREPARED FOR: ARM ALUMINUM 3 I 1'X 2-DB(SIDE WALL�24* o `� ., - - -' -`'- _ Thaw Plans lheand 1017oFlmtda Binding CoOe Edition g z I #10 S.M.S. X 1-), LONG 0 O.C. .�. o 2�110 S.M.S. FROM INSIDE FACE OF (HOLLOW POST COLUMN (HOLLOW OR SNAP) g 1'X 2'DB INTO SCREW SPLINE OF v 2'X 2-1 8-ANGLE W/ (1-EMBEDMENT MIN.) - 1-1/2'LONG�10 / ' o S.M.S. ® 24' O.C. TYP. L14 S.M.S. AND 1ANC0 X 2 1/4' RAIPH E.REMMERT,P.E 39610 SEE PLAN NEW BELOW g I LONG CONCRETE ANCHOR.r"' 2'x2'.125'ANGLE CH _ cAN p 7457 ANCHORS TO FOUNDATION SID OF COLUMNASTENED' JBM&R ENGINEERING,INC. N / SEE PLAN VIEW THIS SHEET 1'X 2' (DB)_W/1-1/2- D W1 (3)01Ox3/14 SMS P.O.BOX 1566 f LONG 0_S:M.S ®24"O.C.f TYP. ;:';;;:;'.. VALRICO,FLORIDA 335 5-15fi6 jr �( ) ;�,-?;;:. .. (813)598-4643 FAX(8 )655-0061 (ROOF BEARING WALL) Qo , 2'X 2'HOLLOW # 2'x2'.125'ANGLE EACH ,`�pat111tttUllrrr r r a ° �'' SIDE OF COLUMN FASTENED���% rrri �1 tit —————————— 1'x2:x.044'BASE CHANNEL '..: ::,:'ti::::.: Ox3/4 S �� ,i n �r (SCREEN SURFACE) WITH(3)/1 MS � �Q. . ,..• �. ::::> : [�E d d ° c� d �3'h - .:::I�': :+�'.�:ii:�:::,,'.Y I ��` •��+ •. f '�, FOUNDATION a EXTERIOR CORNER DETAIL MIN 110 EXTERIOR CORNER DETAIL (PARTIAL-ELEVATION) N.T.S. \,\ }4'.` ° ld a N O (PLAN VIEW) N.T.S. Cc ( t 2 X 3 X 0.045 PATIO TOP RAIL ° tl <4TE OF w` / . 4 — #10 TEK X „ (Per Clip) a ° l �)a°,' y, d,:°,,��.f�•'•!c�QR`�p;.•' `�`.� 3/8'x4'-WEDGE ANCHOR-OR 16lVkAL �,`` 1 THRU ANGLE AND BASE CHANNEL 1 8�reM9Fj j88AA OR FOOTERS WITH BRICK PAVERS ;' SIDE VIEW:OF 2x5_wCONNECTION DETAIL raTs 1 . 4 — #10 TEK X " (2 per side) ' -� -3/8'x4''WEDGE ANCHOR'OR EXPANSION BOLT (3)#10x3/4 SMS OR(4)#BX9/16 SMS EACH THRU'ANGLE AND BASE CHANNEL INTO CONCRETE SLAB _ -- TO FASTEN 2X2X.125 ANGLE TO COLUMN OR FOOTERS'WITH BRICK PAVERS. 2 X 3 X,0.045 PATIO UPRIGHT d 4 f 2"X3"TOP RAIL TO UPRIGHT CONNECTION DETAIL ° 3/8'x4''WEDGE ANCHOR''OR EXPANSION BOLT �''�'•• ° �• (3)/IOx3/4 SMS OR(4)J8X9/16 SMS EACH THRU ANGLE AND BASE CHANNEL INTO CONCRETE SLAB °p • ° a . TO'FASTEN 2X2X.125 ANGLE TO COLUMN OR FOOTER WITH BRICK PAVERS\ :+: :.;"`: t°d'." 2x POST M _ - ? "d + HOLLOW 0 _ ` l ° w ° s JM. ° : °3 J ad 5 AX• 1 ................ (T1P. tSMAX. ru ) 6 y t n `: 2'x2.125'ANGLE EACH SIDE OF COLUMN FASTENED . O tl '" '.::¢.'..,.... .�..'. .. WITH(3)/10x3/4 SMS i; _� :•r:;::':O':::::: :.;:i:a::`".. ::y::'.::'. `'� . }�.:::::.d..::':: ; 1 1 s .f O A• d ' 1'x2'x.D44'BASE CHANNEL`. :;"... i. '�" � � i Q < MIN �` 'i 3-1/2'MIN. .. ° lj •�. 4 ° d ° d 77 < °d ° < v"' EDGE OF SLAB y, 14'. , e < 2x5x.090 1/4'x3"WIKSET,TAPCON (H OW+OR SNAP) ° ° EDGE OF SLAB 1 > OR EXPANSION'T-BOLT 0 24'o.c' 2x3x 045 1/4'x3''QUIKSET TAPCON ° ° ••d ° y' (HOLLOW OR SNAP) OR EXPANSION 'T-�BOLT 0 24'D.C.' ��3/8'x4''WEDGE ANCHOR'OR EXPANSION BOLT \`` ` f \ p PLAN VIE�(Y,OF 2x5 CONNECTION DETAIL -' THRU ANGLE AND BASE CHANNEL INTO CONCRETE SLAB �. : FOOTERS 1WTH BRICK PAVERS. _ PLAN VIEW OF 2x3 CONNECTION DETAILRM y' /r MISC DETAILS SIDE VIEW OF 2x3 CONNECTION DETAIL \ ;: N.TS � �, �+ � i merDRMMorsCOtclax9De-' a � PROPOSEDSCREENROOMADOfFION-CONHECTIONDEFALS ENGINEERING, INC. NE110 IQ W.M6 16 09F Wm= H R NP P.O.0.150 V.".Fixxa+ 4ONPMr Misc(d19/�6[6!J FAK(e/9)&SOiLf Mph Remmelt,P.E a..a m- W • Details `b „ 0 �Id Lea�00 PREPARED FOR: ARM ALUMINUM [111 X 9/16” TEK 15 PER PAN) These Plane and StaadaMe meet the Gth Edtion of the 2017 Rodda Building Cade OPTIONAL ALUMINUM FLASHING NEEDED A TO PREVENT WATER INTRUSION AT CONNECTION � SEALANT (TYP) '; RALPH E.REMNERT.P.E 39610 °HEADER" CHANNEL FASTENER SCHOULE TO HOST STRI ICTURES JBM&R CAN N ENGINEERING,INC. #8 / ° x 3 4 SMS THRU FLASING e r CONCRETE/MASONARY HOST STRUCTURE P.O.BOX 1566 S'floe sls a oo 1n % FASTEN RECEIVER CHANNEL WITH 1/4" x 1-1/2' DRIVE PIN VALRICO,FLORIDA 33595-1565 /tLetu PAN HEADER INTO WITH 3/4" NEO-CLAD WASHER BO fO OR 1/4" x 2-1/4" "QUICKSET' INTO CONCRETE BLOCK WALL (813)598-4643 FAX(813)655-0061 SCIA FAARD Or.)/ INTO PANEL AS NEEDED OR TIE BEAM ®12" O.C. WOOD FRAME HOST STRUCTURE 6j FASTEN RECEIVER CHANNEL WITH 10 x 2" SMS INTO PLYWOOD a n a COVERED FRAME WALL ®8" O.C. MUST FASTEN TO 2X STUDS) °3" THICK x 12" WIDE STANDARAD INTERLOCKING PAN> > STEEL PANEL HOST STRUCTURE FASTEN RECEIVER CHANNEL WITH MIN. 1/4"x THRU BOLTS WITH NUTS �uurr rill, #8 x 9/16 SMS THRU HEADER FLANGE AND WASHERS ®10" O.C. ``,``���f p rr4l,I INTO BOTTOM OF PAN (5 PER PAN) J` `' R "i 12° O.0 AROUND THE PERIMETER PAN ROOF TO WALL DETAIL `���`�,, �` 'G• •��,,'��'� USE SAME FASTENING PROTOCOL FOR ROOF PANS AND COMPOSITE P�AE ••• •• ' ROOF PAN DETAIL TO HEADER CHANNEL AS SHOWN WHEN OVERHANG IS ELEVATED EN96 Z N.T.s ABOVE HEADER CHANNEL TO ALLOW ACCESS WITH SCREW GUN OR DJILL 610 C� :9/16. 7EK_ SPACED ®8" D.C. (TOP & BOTTOM) y� X O ATE OF �1v �[0 l'`.�: ONAL ° ° ° 0 P L O oil .. �a .i. •.� '. .•'•.:: ,l ° ANGLE TO PLUMB ROOF PANEL RECIEVER CHANNEL USE 3/4° X 3/4" X 0.0625" 3 t- "HEADER" CHANNEL FASTENER SCHDULE TO HOST STRUCTURES CONCRETEMASONARY HOST STRUCTURE OR 1" X 1" X 0.0625" ALUMINUM A GLE 0 j / FASTEN RECEIVER CHANNEL WITH 1 4" x 1-1/2" DRIVE PIN TIONS OR 1/4" x 2-1/4" "QUICKSET' INTO CONCRETE BLOCK WALL OR TIE BEAM ®12" O.C. CANTERED FASCIA BOARD CONNEC AN WOOD FRAME HOST STRUCTURE FASTEN RECEIVER CHANNEL WITH 10 x 2" SMS INTO PLYWOOD COVERED FRAME WALL ®8" O.C. MUST FASTEN TO 2X STUDS) ? STEEL PANEL HOST STRUCTURE ..:;/• FASTEN RECEIVER CHANNEL WITH MIN. 1/4"x THRU BOLTS WITH NU1S AND WASHERS ®10" O.C. FOAM COMPOSITE PANEL DETAIL #8 x 9/16" SMS THRU HEADER CHANNEL INTO SUPERGUTTER - ®8" O.C. STAGGERED #8 x 9/16" SMS THRU HEADER CHANNEL TOP FLANGE = - A CHOR PER DETAIL FOR PAN -:.INTO FOAM COMPOSITE PANEL ®8" O.C. �� �pF pwa- (12° O.C. AROUND THE PERIMETER) " -"" USE (5) 1/4" X 4" BOLTS W/ ° � ° " CHOR PER DETAIL FOR PAN WASHERS PER COLUMN/POST ° R COMPOSITE PANEL pea'sys o e'as ° 93" 1HICK x 12" WIDE STANDARAD INTERLOCKING PAN USE (5) 1/4" X 4" BOLTS W/ 1' X 2" MAY BE ATTACHED 1FRt1 S11PQtf;11T1ER INTO " " ",ft; " " _ - - - Ali - 'hd d d dh h 4htl WASHERS PER COLUMN/POST FOR SCREEN USING �1) FASCU BOARD(TYP.Y� - / $8 x 9/16 SMS THRU HEADER BOTTOM #10 X 1 - 1/2" ®6 FROM TOP AND FLANGE INTO COMPOSITE PANEL - ®8" O.C. 1" X 2" MAY BE ATTACHED BOTTOM AND 24" O.C. (12" O.C. AROUND THE PERIMETER) FOR SCREEN USING (1) 1/4" x, O.C.2" SCREW THRU BEAM AND GUTTER #10 X 1 - 1/2" ®6" FROM TOP AND BOTTOM AND 24" O.C. ®8 SIDE NOTCH POST TO CARRIER BEAM - CENTER NOTCH POST TO CARRIER BEAM FOAM COMPOSITE DETAIL I ROOF DETAILS N.TS. ° n NJL'JLIVU W a MGFMH1mrA�� PROPOSED SCREEN ROOMADDMON-PLAN ENGINEERING, INC. -=mf 00060 ' m Cd[ m®1 •n Ot 1p F.Qeuf5W t.&tgFL 35B5 PW-M"9�dt3 FAX013)63d00/ RelphERemmod,P.E Cr av�• a ROOF DETAILS Ib • ,. o 'lI1dJ�4�00 PREPARED FOR. ARM ALUMINUM rheas Pl.' and Slmd.rd.—t the 6th EdiBm d the 2017 Florid.B.Odmg Code 5 - #10 X 4" S.M.S. WITH 3/4" NEOPRENE WASHERS PER 4 FT PANEL ACROSS FRONT & 24" O.C. ALONG SIDES RALPH E REMMERT,P.E.39610 CAN#7457 JBM&R ENGINEERING,INC. P.O.BOX 1566 VALRICO,FLORIDA 33595-1566 (813)598-4643 FAX(813)655-0061 T c ❑ ❑ ❑ ❑ ❑ ❑ T,n n❑"n n n n I]C]C]C]C7 C]I ] -� ' C] 7Qni SEALANT - TYP ON ALL INSTALLATIONS ------------------------- • (5) #8 x 3/4" SMS WITH 3/4" DIAMFJFR NEOPRENE - CLAD STEEL WASHER INTO EDGE OR'dARRIER BEAM, TOP PLATE, OR SUPER GUTTER y / N.T.S. d ✓ Cn Lli / - :'= 12" PANEL / 0 NOTE: MINIMUM SLOPE = 1/2" PER FT - ROOF PAN DETAIL ' ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ N.T.S. ad n Qe. CONCRETE n � • a #8 x 9/16 SMS (5 PER PAN) FOAM COMPOSITE TO SCREEN WALL HEADER DETAIL (n j I #8 x 9/16 SMS FOR COMPOSITE - 8" O.C. ® BOTTOM , "HEADER" CHANNEL FASTENER SCHDULE TO HOST STRUCTURES `.�```��R_..... /STEECj ��` Q. '�. (n PANE CONCRETE/MASONARY HOST STRUCTURE � �/ . \GEN`SF•••• •� :D /�D FASTEN RECEIVER CHANNEL WITH 1/4" x 1-1/2" DRIVE PIN �% jj OR 1/4" x 2-1/4" "QUICKSET" INTO CONCRETE BLOCK WALL OR TIE BEAM ® 12" O.C. _ No,39610 _ � _ WOOD FRAME HOST STRUCTURE * jr_ > FASTEN RECEIVER CHANNEL WITH #10 x 2" SMS INTO PLYWOOD *p TE W COVERED FRAME WALL ® 8" O.C. (MUST FASTEN TO 2X STUDS) �� •• ST STEEL PANEL HOST STRUCTURE FASTEN RECEIVER CHANNEL WITH MIN. 1/4"x THRU BOLTS WITH NUTS AND WASHERS ® 10" O.C. `S�•• �- `� • ROOF PAN OR F`QAMZO�E PiAN�rAIL f N.T.S. ROOF DETAILS 0 smFm mw,xum PROPOSED SCREEN ROOM ADDITION•PLAN ENGINEERING, INC. RDFADQawmwmm 16 m w1 M Q M P.O.Boxier Ni FAXW3)&W= RBIph E.RemnrerR P.E. ROOF DETAILS lb � exc sm rrr5 y 0 313dON00 PREPARED FOR. ARM ALUMINUM `11111111 1111 1/F/ These Plms and Stmdards meet the 6th Edition /// \\\, / of the 2DI7 Florida Building Code \\\ o M �• c i RALPH E REM MT.P.E.39610 TYP. SMB . 39610 JBM&R ENGINEERING,INC. BOX SIZE VARIES d p ° * * 31ALRICO,F�RIIDA1566 33595-1566 ..Q C01S 598-4643 FAX(813)655-0061 STATE OF GUTTER ATTACHED�l •'••• P••:'��- p ° a COMPOSITE ROOF PANEL (5) 2/ #8 X 9/16I-,j F 4OIv�B a — #10 X 4 BEAM SMS W/ NEO 5� ' •... ��\\ #12X3/4" SMS EACH SIDE, p WASHER PER 4 FT PANEL 8 O.C. STAGGERED // ,�,. (SEE ATTACHMENT SCHEDULE) 10 X 2 SMS t ° PAN ROOF: (5) #8 X 9/16" _ ° TEK PER 1 FT OF PANEL 1"X 2"OB 1.5' 2.1 5"X.062" RECEIVING CHANNEL a r f : 1/4" CONCERET ANCHOR EXISTING CONCRETE TIE BEAM OR X `` WOOD FRAMED WALL (BY OTHERS) I 2 X 0.050" STRAP @ EACH BEAM LOCATIV N l ATTACHMENT SCHDULE EXTRUDED SUPER GUTTER— BEAM X 2.125" X BEAM SONRY WALL WOOD FRAME WALL BEAM SIZE #12 SMS CONCRETE ANCHORS 1/4" LAG SCREWS 0.082" RECEIVING EACH SIDE CACH SIDE EACH SIDE CARRIER BEAM CHANNEL 2"X4" PB 3 2; 2 2"X4" SMB 3 2,1 2 #12 SMS @ 24" 2"X5" SMB 3 z j ` 2 0.C., TOP AND 2"X6" SMB 4 W 3:1 3 NOTE: SMS TO BE PLACED A MINIMUM OF 0.5" BOTTOM WITHIN 3" 2"X7" SMB y5\• i 3: 3 FROM EDGE AND A MINIMUM OF 0.75" O.C. OF END OF BEAM. 2"X8" SMB 6 j 4;j 4 UNLESS OTHERWISE SHOWN. 2"X9"X.072" SMB 6 41 4 BEAM TO GUTTER/ SCREEN ROOM 2"X9"X.082" SMB r 6 r41 4 N.T.S. 2"X1O" SMB N.T.S. 7 a4 4 _ BEAM CONNECTIONS BEAM TO WALL dQ ] e SM FOR PD�r:m�s�dl�w ItR PROPOSED SCREEN ROOM ENGINEERING, INC.' I®FIOQmn= 10 YO[ If]®1 M C[ M PA.Ba Jae ViHalH3iW5 16e11pp�(e191�9f•, FAi'IBf316.SQ791 s�"�iw-��Li eam -i owe cowc.ccre C'- o� avc p R&phE Remmed,AE BE I� 11 -� 0 3J�dON00 PREPARED FOR: 4" THICK CONCRETE SLAB (NOMINAL) AS FOLLOWS ARM ALUMINUM These Plea aid standade meet the 6th EdltTm of the 2017 Raid.Ba1d'm,code _ • 2500 PSI COMPRESSIVE-STRENGTH AT 2-8­13-AYS • REINFOR"CEMENT: 6"X6" # 10/10 W.W.M. OR TOERMESH' � — RALPHE ANf 457.E.39610 JBM&R ENGINEERING,INC. P.O.BOX 1566 66 •,, VAPOR BARRIER. )5984F3 FAX (813) 15— (613)598-4643 FA%(813)655-0061 r' TERMITE PRETREAT IS REQUIRED ONLY IF RESIDENCE HAS BEEN BUILT FOR 3 YEARS OR MORE, AND THE PROPOSED CONCRETE SLAB WILL BE IN " -•,,,, -CONTACT WITH THE RESIDENCE. \ 5., ° Q�•�••E•.!��c''� • IF FILL MATERIAL IS NEEDED, IT SHALL BE FREE OF VEGETATION AND FOREIGN " _ 610 MATERIAL. THE FILL SHALL BE COMPACTED TO ENSURE ADEQUATE SUPPORT OF THE FOUNDATION. = TE OF :•cv CRACKS OR HAIRLINE STRESS CRACKS MAY STILL FORM / •• ••• �C�.�� .y : .. ONqL E MONOLITHIC FOOTING REQUIREMENTS FOR SCREEN ENCLOSURES FOOTING SIZE REBAR (height x width) 1=1 � I=1 I I=1 I I=1 I -III—III—III — I- — —__ — —I— n n I�=ITI—I —II a AT,=1 1=11�=11�=1 I—III—I 1=I�=11F=�� 8 xs (U.O.N.) 1 - #5 (U.O.N) —1 I I—I I I—I I I— __ _ 1 11=1 11=1 11=T=1 1=11 I—I 11=1 11=1 1I- 11=1 11=1 I I=1 I I=1 I I=1 11=1 11=1 11=1 11=1 I I—III—III—III—III—III=1 I I_ 1—III—III-1 i1-1 1=1 11=1 I-1 I1 I I'-1 I H I I—I I Ia 11=1 11=1 11=-I 11= =III=III=111-III=III=III III-I=III= II=III=III=III—III=III=1 MONOLITHIC FOOTING REQUIREMENTS FOR CARPORTS AND SOLID ROOFS L^III --III=III=III=III=III=III=III—III=III=III=III=III—III-111 FOOTING SIZE REBAR MAX. TRIBUTARY LOAD WIDTH �1=1=ll L1=1 I I-IL=1�=I 11=LJ=JJ 1=1 LI-I L=1 I�=U- LI=III—III=IJ=ILI=J1=Ll=Ll1—III=1LI-1=J=LI= (width x height) (distance between supports) -I I I—I I=11=I I=III=I I I=I I I=I I I=I I I=I I I=III=IhT—F =III=11=III=III-I I I—III=I I I=I I I=111=II-111=" —I I—III=1I1=111—I1I-11-I I1=1I1— n r n '�rl I I—III—� 8 x8" 1 — #5 UP TO 7—9 12"x8" 1 — #5 FROM 7'-9" TO 12'-3" 12"x8" (U.O.N.) 2—#5 (U.O.N.) GREATER THAN 12'-3" SPAN CONCRETE nn n PROPOSED SCR NROOMAOOmON-CONCRUEDETAILS ENGINEERING, INC. 0 Me FM wart a car84m" f&�FA M30M WAN= ti Imp P.O.Bal i58B Vi1a4H&'11a4 UWFf—ffll3)5la4W FAXM3)B'61tlB1 �rre�e�ws• ium -i oleo wNc.ccre Q� om rna . CONCR `/� RO1phE Rammed,P.E 0�1�_�his dm N19 Q- e- 1� y , T , .,..:.:.:.. �,.. :.,.::......:...._ n... .v ...v v. .. .-. v.. r ..._ .._..y.. AID, ..,. .:,...r. .... .:a,.t 1 ..:::.........:.,:.r.: !.._I :....:::_ ...•>�-. ......._,..::•-,-1,•: i?:i }.r F{r'G/ l'i_�:5 ,'ti��i 1. .., -':;:-,:.,__;::;a.:,. _ �•r -'l� t.:._ _ :s.. ,..,._.:.., t. "ll� r. yf- •:t.;'.-tp 'i ."if ?:.F( u f�4 t +d ti �:�3^�� ''a��I `'�<,,:,; r:;•_: a.. ;.j: �.,,.:,.:t.+vn}�„s:a�t•-'+z•�t..�1; ....:.,<-.;:,..,-...`tyl<A J.rni,"'.:In- .!;rt%kf.. r.;l',;^rh;. _,'3r:i15: - - ___-_ i::,.v._ _-t,._.yt.• .. ...v--.v'.r.i,^.-v�:'rr:.r::..:.� vl.: .<'1�,. v..t.: _:::t;.r :4i.,t{ ".✓-'�,S,r^ _�`7"1-;• .�.�..�........ ...:�:..f..- !:.^...........v:-....,n'..•e,.4...,Y1i.iF......v.:.,.�v.v�:,::..,�.4''vi _ - i�l?: U,,�I.v}...C'F/... rir;"e >]`rt:t}.!i, u-a�..�::�'��"''r:��c::a�.:a.:i,_«�s:�:.----:��w leer:_•6...�c_�....._.s.:.-.,,nGcu_:,r:_.,.z.�_.:x<,..-.:.r::.::��.iW. BCIS Home Log In User Registration HotToplcs I Submit Surcharge I Stats&Facts I Publications ( Contact Us BCIS Site Map I L ��O1'I(�a it.�"'Iffij 'i'f=, Product Approval !' -USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail ,i{;R'i'f? rj,-'r`° FL# FL21443-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived !J Product Manufacturer Structall Building Systems, Inc. Address/Phone/Email 350 Burbank Rd. Oldsmar, FL 34677 (813) 855-2627 info@structal1.com Authorized Signature Kenny Matuza info@structal1.com Technical Representative Ken Clay Address/Phone/Email 350 Burbank Road Oldsmar, FL 34677-4906 (800) 969-3706 kclay@structall.com Quality Assurance Representative Ken Clay Address/Phone/Email 350 Burbank Road Oldsmar, FL 34677 (800) 969-3706 kclay@structall.com Category Roofing Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or a Lice Professional Engineer ' l_J Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Do Kim Evaluation Report Florida License PE-49497 Quality Assurance Entity TI RADCO LLP dba RADCO A Twining Company Quality Assurance Contract Expiration Date 12/31/2022 Validated By James L. Buckner, P.E. @ CBUCK Engineering t.a Validation Checklist- Hardcopy Received Certificate of Independence FL21443 R1 COI certificate of independence.pdf Referenced Standard and Year(of Standard) / . . , ' ` RESTRCTIONS OF RECORD WHICH MAY AFFECT THE CBW CONCRETE BLOCK WALL Pee POINT OF COMPOUND CURVE ` t }+.— :-�•^:� i."'.::.,rr;-:. _.rr-,�"-;�:...�- ry-�"i Fm•+„'4' : sfitif7v`'Wt'd� (T-- -crt-"""'.'z:.--^,"-%;�l- .:,., ...;k.-:u•:_:: .,,... ,.,1__._;,'.�'q",.-F`�'" :5j''-": '�ti^it1r.:!?-1}�',:!-''-',';';� I,:T - -.-�., i#3, k yx:..:. _ t:Y qv- S'hS'7`::y'�i �{4�,.-Eh, .T... :.frt.: !,��' -e�•♦ -- 4' - L ._tax: - .ea'�h r ,:,t:. i•['ji _ _ ..t.t _ �^y�.:,7':l•:I:� ^5�i:,±i: ?f J 1..1.r�1 .L'!� sta!: ..i'F:r:ii;'...x,q'-'t` "+ f F "ti;• r ,.r.• �i< ten. j y ..c.+ `` '=i.r':j`�t�:rL i•.,,.1 .a. - :!:4�� ':.\.1i '`[t•:,.dt.r4lu •>`�i+>' F�"+iv,l.,.,m..:�-: ?'I�,- ..If'::;i,•,.> .?"."f-s�z _a: ,w .•#'n•Is'- t:,. C 3,t��•s"� �:=:�:;a1::':7`>s:N::+'r"� r'1..•�:r: 'r,7,.��. "-tr;+„-JJi'' - �•tg:,},.--d .,ii`--uF:ii•e•f#.; 7 _ :ri.� -,;74:'r's",,:,�!;i..�— :ii�1r, ;?n r'='�fi°.r�U� �{;•^i 74•,I+}�.-Y>-'+.�-fi; .#i;G w�"'i'��`�i 1�1VY :-.�J;' �+,�.-�• J'��� � ��3:r t'c' h'.,u:�i,.�<•.. .....- ,1�t 5 d J.pl �'!y � •._ v.J.V_Fikna�+:+i.:,i5".:r_1.TSS.iA.:r:L'��.L-Scv.c_: �i::�:�a, ,��R,I#�rj rn,*•s�',...�r:h.n:+:�i(,s,ciS�'krt�^��ya:''.,f.'•.,-.-~��-vy#44��`_��1:�1•�fY;..,?;•L`s�7;.�t ,!:tc���'t',SY may-_.__ ___ __ _ _ .•,t•'..t=:,.�,,.,.,:�• :.,,"•T;F,.::;-ax,.r,.-...,:'i;r;i,h t(.e iFi, tee:: ::,. ,.r.• .{.,. i .rh's"a -"tf3�i''� g+. •..a,:..,..,.....,L,.•;,.:a.,..,at,.,,t.,•n..•,y.!� i'GiiN3,.,...r...�29:..!„ ?5+.,:7i'�t .:it-_qfY: r'i'1:...7.x .:rc.n- L:, :.: "/`r'f. ,�y� 7:r}�,rr-#'�#... ul-,,;1. .,�.u7. -t. t,,5;.s, ,.,{:'i .,. :arc.:^ =:a1 .i:b�+t� r:%. .•�'. '1'ti� tt,�.j;i:" �-t it..-,.,..... _ ...:�.,..i,,,,'::,.:i+:.k'to.l::.::'fs'::,,.,:a.:i`:�4r,-.44;1!Gin'i!l::t'tii: Sii_�:..:z,;31t;:_.A,• _ w, f�1.�1iLL,�1eA:....rttr.S.1 +a ..•'_Geu,d'�_::_:.�:tt:'vy;cta':+til,�4:�-:;:-..-.+,:u c.l.,.r:..,v�•t'.'+"•:�s.Ysr!u:!�.^::auc-,.,_.:.c. _�.'�ksswGLr-•,.:! BCIS Mome l Log In User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications l Contact Us BCIS Site Map l L d,,.bFr a . ;. Product Approval USER:Public User Product Approvai Menu>Product or App#ication Search>Application List>Application Detail "If yr�Ss� ."sa( ?E si FL# FL21443-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived 0 Product Manufacturer Structall Build!ng'Systems, Inc. Address/Phone/Email 350 Burbank Rd. Oldsmar, FL 34677 (813) 855-2627 Info@structall.com Authorized Signature Kenny Matuza info@structall.com Technical Representative Ken Clay Address/Phone/Email 350 Burbank Road Oldsmar, FL 34677-4906 (800) 969-3706 kclay@structail.com Quality Assurance Representative Ken Clay Address/Phone/Email 350 Burbank Road Oldsmar, FL 34677 (800)969-3706 kclay@structall,com Category Roofing Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or a Lice Professional Engineer 13 Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Do Kim Evaluation Report Florida License PE-49497 Quality Assurance Entity TI RADCO LLP dba RADCO A Twining Company Quality Assurance Contract Expiration Date 12/31/2022 Validated By James L. Buckner, P.E. @ CBUCK Engineering fZ Validation Checklist- Hardcopy Received Certificate of Independence FL21443 R1 COI certificate of independence.pdf Referenced Standard and Year(of Standard)